Loading...
HomeMy WebLinkAboutCT 00-16; WATERS END; GEOTECHNICAL APPROVAL; 2002-10-28e- Lawson & Associates Geotechnical Consulting, Inc. October 28, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, CA 92009 ee Project No. 020039-01 Subject: Geotechnical Approval of the Generator Building Foundation Excavations Lot 225 at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, Carlsbad Tract CTOO-16, City of Carlsbad, California References: Geocon, Inc., 2002, Poinsettia Properties; Sewer Pump Station, Carlsbad, California, dated October 16,2001. Lawson & Associates Geotechnical Consulting, Inc., 2002, As-Graded Report of Water's End, Planning Areas 2,3, and 4 Carlsbad Tract CT 00-16, City of Carlsbad, California, Project No. 020039-01, Dated October 3,2002. In accordance with your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has prepared this letter-report to provide geotechnical certification for the foundation excavations of the Generator Building Adjacent to the lift station at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, in the city of Carlsbad, California. Based on our observation and probing, the above-mentioned foundations have been excavated into finn and unyielding fill materials. These materials are as anticipated in the design geotechnical report referenced above. These materials have suitable bearing capacity as outlined in the referenced design report. Based on our review there are no utility trenches below the foundation. At the time of our inspection there was no loose material within the exposed trenches, should any loose material fall into the trench excavation it should be removed prior to pouring. Line and grade is not the purview ofLGC. If you should have any questions, please do not hesitate to contact us. Sincerely, ~ Tim Lawson, RCE 53388, CEG 1821 Principal Engineer/Geologist Distribution: (2) Addressee (2) City of Carlsbad Attention: Mr. Dale Schuck 1020 Calle Cordillera • Suite 101 • San Clemente, CA 92673. (949) 369-6141-Fax (949) 369-6142 October 24, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, CA 92009 " "-'6 ... ,"t., fj"''''.'-''''' I : ,--. -. { ,. " . "," , J '-Proje~tN<i:' Oi'0039~0l - Subject: Geotechnical Approval of As-Graded Condition for the Generator Building Lot 225 at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, Carlsbad Tract CTOO-16, City of Carlsbad, California Refereltces: Geocon, Inc., 2002, Updated Geotechnical Investigation, Poinsettia Properties; Planning Areas 2,3, and 4, Carlsbad, California, dated February 19,2002. Lawson & Associates Geotechnical Consulting, Inc., 2002, As-Graded Report of Water's End, Planning Areas 2,3, and 4 Carlsbad Tract CT 00-16, City of Carlsbad, California, Project No. 020039-01, Dated October 3,2002. In accordance with your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has prepared this letter-report to provide geotechnical certification for the Generator Building Pad Area, Adjacent to the lift 'station at Water's End, Poinsettia Properties Planning Areas 2, 3, and 4, in the city ofCl;!.f{s?aq, ,California. 'Gradiiig of the site as a whole was carried out in the period between May 28; 2002 and August 30, 2002. The earthwork operation was completed in general accordance with the recommendations set out in the referenced report and was observed/tested under full-time supervision from a representative of this firm. The subject building was over excavated to a depth of 5 feet, extending a minimum of 5 feet outside the building footprint to expose competent terrace materials. The over excavated area was replaced with compacted:fill. In-situ density testing carried out, in this fill material indicated a compaction of 90 percent relative compaction or greater. If you should have any questions, please do not hesitate to contact us. Sincerely, LAWSON & ASSOCIATES GEOTECHNICAL CONSULTING, INC. Tiin Lawson, RCE 53388, CEG 1821 Ptfucipal Engineer/Geologist ~ , ~ ~ 1 r' Di~trlJ:jtition': '.' (2) Addressee ~ . " , (2) City of Carlsbad Attention: Mr. Dale Schuck .'. '. • '~ .,.:< i .. '-.I ,1.020 Calle Cordillera. Suite 101 • San Clemente, CA 92673 • (949) 369·6141 • Fax (949) 369·6142 { I I j Lawson & Associates Geotechnical Consulting, Inc. October 24, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, CA 92009 Project No. 020039-01 Subject: Geotechnical Approval of As-Graded Condition for the Generator Building Lot 225 at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, Carlsbad Tract CTOO-16, City of Carlsbad, California References: Geocon, Inc., 2002, Updated Geotechnical Investigation, Poinsettia Properties-; Planning Areas 2,3, and 4, Carlsbad, California, dated February 19, 2002. Lawson & Associates Geotechnical Consulting, Inc., 2002, As-Graded Report of Water's End, Planning Areas 2,3, and 4 Carlsbad Tract CT 00-16, City of Carlsbad, California, Project No. 020039-01, Dated October 3,2002. In accordance with your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has prepared this letter-report to provide geotechnical certification for the Generator Building Pad Area Adjacent to the lift station at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, in the city of Carlsbad, California. Grading of the site as a whole was carried out in the period between May 28, 2002 and August 30, 2002. The earthwork operation was completed in general accordance with the recommendations set out in the referenced report and was observed/tested under full-time supervision from a representative of this finn. The subject building was over excavated to a depth of 5 feet, extending a minimum of 5 feet outside the building footprint to expose competent terrace materials. The over excavated area was replaced with compacted fill. In-situ density testing carried out, in this fill material indicated a compaction of 90 percent relative compaction or greater. ;. If you should have any questions, please do not hesitate to contact us. Sincerely, LAWSON & ASSOCIATES GEOTECHNICAL CONSULTING, INC. Tim Lawson, RCE 53388, CEG 1821 Principal Engineer/Geologist Distribution: (2) Addressee (2) City of Carlsbad Attention: Mr. Dale Schuck 1020. Calle e.ordUlera • Suite 101 • San Clemente, CA 92673 • (949) 369!'6141 • Fa~ .(949): 369 .. 61'42; Lawson & Associates -G-e-o-te-c-h-n-i-c-a-.-c-o-n-s-u-It-in-g-,-.-n-c-.---------------"l"'!'UL~·Ii"'"· ":'j'~""'iO~20~02~-) " October 28, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, CA 92009 Project No. 020039-01 Subject: Geotechnical Approval of the Generator Building Foundation Excavations Lot 225 at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, Carlsbad Tract CTOO-16, City of Carlsbad, California References: Geocon, Inc., 2002, Poinsettia Properties; Sewer Pump Station, Carlsbad, California, dated October 16, 2001. Lawson & Associates Geotechnical Consulting, Inc., 2002, As-Graded Report of Water's End, Planning Areas 2,3, and 4 Carlsbad Tract CT 00-16, City of Carlsbad, California, Project No. 020039-01, Dated October 3,2002. In accordance with your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has prepared this letter-report to provide geotechnical certification for the foundation excavations, of the Generator Building Adjacent to the lift station at Water's End, Poinsettia Properties Planning Areas: 2, 3, and 4, in the city of Carlsbad; California. . Based on our observation and probing, the above-mentioned foundations have been excavated into firm and unyielding fill materials. These materials are as anticipated in the design geotechnical report referenced above. These materials have suitable bearing capacity as outlined in the referenced design report. Based on our review there are no utility trenches below the foundation. At the time of our inspection there was no loose material within the exposed trenches, should any loose material fall into the trench excavation it should be removed prior to pouring. Line and grade is not the purview ofLGC. If you should have any questions, please do not hesitate to contact us. Sincerely, LAWSON & ASSOCIATES GEOTECHNICAL CONSULTING, INC. Tim Lawson, RCE 53388, CEG 1821 PJjilcipaj E~gineer/Ge0Ibgist '. PistriJ>utiort: . (2) Addressee " (2)' City of Carlsbad Attention: Mr. Dale Schuck "0', • . , ~ /' • • I .: 1020 Calle Cordillera • Suite 101 • San Clemente, CA 92673 • (949) 369·6141 • Fax (949) 369·6142 Lawson & Associates Geotechnical Consulting, Inc. October 28, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, CA 92009 302002 Project No. 020039-01 Subject: Geotechnical Approval of the Generator Building Foundation Excavations Lot 225 at Water's End, Poinsettia Properties Planning Areas 2, 3, and 4, Carlsbad Tract CTOO-16, City of Carlsbad, California References: Geocon, Inc., 2002, Poinsettia Properties; Sewer Pump Station, Carlsbad, Califorllia~ dated October 16, 2001. Lawson & Associates Geotechnical Consulting, Inc., 2002, As-Graded Report of Water's End, Planning Areas 2,3, and 4 Carlsbad Tract CT 00-16, City of Carlsbad, California, Project No. 020039-01, Dated October 3,2002. In accordance with. your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has prepared this letter-report to provide geotechnical certification for the foundation excavations of t4e Generator "Building Adjacent to the lift station at Water's End, Poinsettia Properties PlanniIig Areas' 2,3, and 4, in the , <?ity of Carlsbad, California. Based on our observation and probing, the above-mentioned foundations have been excavated into :fum and unyielding fill materials. These materials are as anticipated in the design geotechnical report referenced above. These materials have suitable bearing capacity as outlined in the referenced design report. Based on our review there are no utility trenches below the foundation. At the time of our inspection there was no loose material within the exposed trenches, should any loose material fall into the trench excavation it should be removed prior to pouring. Line and grade is not the purview ofLGC. If you should have any questions, please do not hesitate to contact us. Sincerely, LAWSON & ASSOCIATES GEOTECHNICAL CONSULTING, INC . . ~. Tim Lawson, ReE 53388, CEG 1821 Ptjt;lcip~l. E~gineer/Ge910gist Di~~~~J~~':::' ::\2) Ad<kessee . ' ':' . '::'~.,' . '(2). City of Carlsbad , ' ." ., . , '. -' !: : , / .' >~}-... . .' . ..,', ~ ..... Attention: Mr. Dale Schuck j 1020 Calle Cordillera • Suite 101 • San Clemente, CA 92673· (949) 369·6141 • Fax (949) 369·6142 Lawson & Associates Gf,!otechnical Consulting, Inc. October 24, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, CA 92009 Project No. 020039-01 Subject: Geotechnical Approval of As-Graded Condition for the Generator Building Lot 225 at Water's End, Poinsettia Properties Planning Areas 2,3, and 4, Carlsbad Tract CTOO-16, City of Carlsbad, California References: Geocon, mc., 2002, Updated Geotechnical mvestigation, Poinsettia Properties; Planning Areas 2, 3, and 4, Carlsbad, California, dated February 19, 2002. Lawson & Associates Geotechnical Consulting, Inc., 2002, As-Graded Report of Water's End, Planning Areas 2,3, and 4 Carlsbad Tract CT 00-16, City of Carlsbad, California, Project No. 020039-01, Dated October 3,2002. m accordance with your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has prepared this letter-report to provide geotechnical certification for the Generator Building Pad Area Adjacent to the lift station at Water's End, Poinsettia Properties Plann.ing Areas 2, 3, and 4, in the city of Carlsbad, California. Grading of the site as a whole was carried out in the period between May 28, 2002 and August 30, 2002. The earthwork operation was completed in general accordance with the recommendations set out in the referenced report and was observed/tested under full-time supervision from a representative of this finn. The subject building was over excavated to a depth of 5 feet, extending a minimum of 5 feet outside the building footprint to expose competent terrace materials. The over excavated area was replaced with compacted fill. m-situ density testing carried out, in this fill material indicated a compaction of 90 percent relative compaction or greater. If you should have any questions, please do not hesitate to contact us. Sincerely, LAWSON & ASSOCIATES GEOTECHNICAL CONSULTING, INC. Tim Lawson, RCE 53388, CEO 1821 Principal Engineer/Geologist Distribution: (2) Addressee (2) City of Carlsbad Attention: Mr. Dale Schuck 1020 Calle Cordillera • Suite 101 • San Clemente, CA 92673· (949) 369·6141 • Fax (949) 369·6142 e Lawson & Associates Geotechnical Consulting, Inc. July 19, 2002 Mr. John Mecklenburg John Laing Homes 701 Palomar Airport Road, Suite 300 Carlsbad, California ~2009 • Project No. 020039-01 Subject: Observation and Approval of the Basal Excavation for Sand Shell Sewage Lift Station at Water's End, City of Carlsbad, California Reference Geocon, Inc., 200 I, Geotechnical Investigation, Poinsettia Properties, Sewer Pump Station, Carlsbad, California, dated October 16, 2001. In accordance with your request, Lawson & Associates Geotechnical Consulting, Inc. (LGC) has observed the excavation bottom for the Sand Sewage Lift Station at Water's End, City of Carlsbad, California. Based on our observation, the bottom of the excavation is cut into bedrock of the Santiago Formation. This bedrock is considered geotechnically suitable for bearing of the subject structure. During our observation, we noted that some loose material had collected at the base of the excavation due to the method of excavation employed by the contractor. We requested that this material be removed from the excavation. After removing the loose material the contractor placed a filter fabric along the base of the excavation (Mirafi 140n) and then placed approximately I-foot of %-inch crushed rock above the filter fabric to form a suitable foundation to work on, and prevent future construction activities from disturbing the base of the excavation. We consider the above-mentioned excavation and rock blanket to be suitable for their intended purpose and provide suitable bearing capacity for the designed structure (3000 pst) If you have any questions, please do not hesitate to call. The opportunity to be of service is appreciated. Sincerely, Tim Lawson, RCE 53388, CEG 1821 Principal Engineer/Geologist TJL/kjb Distribution: (2) Addressee (1) City of Carlsbad Attention: Mr. Dale Schuck 1020 Calle Cordillera • Suite 101 • San Clemente, CA 92673 • (949) 369-6141 • Fax (949) 369-6142 . ." .. : -l:' -: • • ~ " ' '-'!:-, ~. r. ~ • " ,~ 'J": _ ... . , SAND SklELLlJFT STATION CITYi6'F CARLSAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST " ~. t:'~ . SAND SHELL LI,FT STATION CITY OF CARLSBAD INSTRUM'ENTATION & CONtROL HARDWARE-'-" FACTORY ACCE'PTA;Nt6.E TEST :1i/~:' ,-. >};: ':,: ,J " . .~' . ~~: .. .: .. . , .; ~ . ' -: ..... , ,-;A.' .,~:,.\~'" < ,~ .. "'-.. .. ' -• loA ~; "'';, -'Jf .. -' TAB 1 2 3 4 ," vo SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST TABLE OF CONTENTS DESCRIPTION FACTORY ATTENDANCE SIGN-UP SHEET FACTORY TEST REPORT FOR MAIN CONTROL PANEL FACTORY TEST REPORT FOR BUBBLER CONTROL PANEL FIELD INSTRUMENT BILL OF MATERIALS SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST SECTION 1 FACTORY ATTENDANCE SIGN-UP SHEET -f' A SUBSIDIARY OF: ;1 '-J..--Integ~ted C"'i--..:· -Electncal _ l ~ Services I-NSTRUMENTATION & CONTROL FAT ATTENDANCE SIGN-UP SHEET PROJECT NUMBER: 2123 . PROJECT NAME: SAND SHELL LIFT STATION CITY OF CARLSBAD DATE: ________ _ NAME COMPANY TITLE . FATSIGN·UP SHEET.DOC EMPLOYEE No TELEPHONE SESSIQN-· ( 1 SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST SECTION 2 FACTORY TEST REPORT MAIN CONTROL PANEL I &C Bill of Materials SAND SHELL LIFT STATION CITY OF CARLSBAD, SAND SHELL LIFT STATION 7 ~ Areller Westerll COllstrue/ors 8775 Aero Drive, Suite 335 Sail Diego, Ca 92123 Mtlllitfilctllrer Dwg Imtll!evice Tag Qty Part# Sub Sect Spec Sect Remarks Area / Locatio,,: GENERA TOR /CONTROL ROOM Eqllipt / Pallel: MAIN CONTROL PNL ADEM CO NA MCP INTRUSION CONTROL PANEL VISTA-20HW 9 16726 Intrusion System Control Panel, wI 16.5VDC 25VA Transformer, Selectable Response 10/350/750msec, Progeammable Swinger Suppression, wI 4202 4-0utput Relay Board Option, Upto 8 Hardwired Zones, Includes Manufr i-Day StartuplTraining (14x10x3) -..... ' ... -------.-----=-~----.-:~------------------------------------------------- ANY E-7 MCP ELECTRICAL DEVICES & ACC 2 DE MARC 13 17000-2 Telephone Demarcation Block, Double Output BEST POWER (POWERWARE) E-8 MCP UPS SYSTEM & POWER SUPPLlY 1 05146635-5501 14 17000-2.11 Uninterruptible Power Supply, 2.2 kVA, Powerware PW 5125-2200, 120VAC In/Out, 14 min Backup time @ 2.2kVA, 9.9x8.1x19.5 (HWD)-[Replacment for Fortress 0520-2250-Uj --p _. --.---.-- BEST POWER (POWERWARE) E-8 MCP UPS SYSTEM & POWER SUPPLlY 05146639-5501 14 17000-2.11 UPS External Battery Pack, Model PW5125, 48V EBM, to be used with 5125-2200 UPS, Total 26 min Backup Time, 9.9 x 6.4 x 18.7 (HWD) • •• ,_ 'w' _ •• _. ___ • ______ _ BLACK BOX NA MCP MODEM -STANDALONE MD1000A 12 17000-2.14.2 Modem, Model 3600 Standalone BRADY SLEEVE E-7 MCP ELECTRICAL DEVICES & ACC PS-187-2W-4 13 17000-2 Wire Markers, Heat Shrink, 2" Length (4 per label), 1000 I Roll .' .. -... --..... ------. ------------------------------ CUTLER-HAMMER E-7 MCP ELECTRICAL DEVICES & ACC 5 10250T2oKB 13 17000-2 Selector Switch, Assembled, 2 Position Maintained, Black, 1 NO/NC Contact .. .. . .. _ .... -.. -..... ------------------------ CUTLER-HAMMER E-7 MCP ELECTRICAL DEVICES & ACC 1025OT3OB 13 17000-2 GUTLER-HAMMER E-7 MCP ELECTRICAL DEVICES & ACC 2 10250T37NG 13 17000-2 Indicating Light, Glass Lens, Green, 120 VAC, PIT, NEMA 4X .... " ... -.. _--._--_._-- CUTLER-HAMMER E-7 MCP ELECTRICAL DEVICES & ACC 2 10250T37NR 13 17000-2 Indicating Light, Glass Lens, Red, 120 VAC, PIT, NEMA 4X CUTLER-HAMMER E-7 MCP ELECTRICAL DEVICES & ACC 2 10250T37NW 13 17000-2 Indic;ating Light, Glass Lens, White, 120 VAC, PIT, NEMA 4X DIVERSIFIED ELECTRONICS E-7 MCP INTRINSiCALLY SAFE RELAYS 3 .IS0-120-AFA 11 17000-2.16 IS Switch Relay, 12oVAC, Enclosure Style A, 1 SPST NO iDA Contact, wI Din-Mount Relay Base ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 4 101598.26 13 17000-2 Terminal Block DIN Rail, PR5, Prepunched, 6 ft. ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 10 103002.26 13 17000-2 Termi~aIBI()ck End Stop, 6 mm . Wel/IJesdIJY, Octuber 16, 2002 MAIN CONTROL PNL Pagelof5 t MllIllIfacIlIrer Dwg IllstiDevice Tag Qty Part # Sub Sect Spec Sect Remarks 0;- Area / Locatioll: GENERA TOR /CONTROL ROOM Eqllipt / PllI!ei: MAIN CONTROL PNL ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 200 115116.07 13 17000-2 Terminal Block, Grey, M4/6, 6 mm Spacing '.. .-.-. '--'--'--"'~---~ ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 25 115657.25 13 17000-2 Fuse Block, Grey, 8mm, Type M4/8.SF .. . .. -. "~ .... --------- ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 6 116951.15 13 17000-2 Fuse Block End Section, Grey, 8 mm .. . ----.. ------- ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 10 118368.16 13 17000-2 Terminal Block End Section, Grey, 6-10 mm TB's -. -0-'_"'_ • _______ ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 6 165113.16 13 17000-2 Terminal Block, Ground, GreenlYellow, 6mm •• 0. ________ ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 6 165275.00 13 17000-2 Terminal Block, Isolated Ground, Yellow, 6mm -.. -.-.--------_. ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 15 173523.11 13 17000-2 Fuse Block Comb Type Jumper Bar, 10 Pole .. 0-. __ .... ___ . ___ .. ___ ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 20 174784.20 13 17000-2 Terminal Block Jumper Bar, Universal, 2-Pole -.0. ___ " __ • __ ... ___ ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 10 176679.10 13 17000-2 Terminal Block Jumper Bar, Preassembled, 10 Poles, for 10mm T8 ... -. ------~.--------- ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 236000.04 13 17000-2 Terminal Block Markers, RCT610, 6x10mm Top Marking, 1 Card 1100 Markers (Old Part No. 256000.04) .. . .. ---.... ---_. ENTRELEC E-7 MCP ELECTRICAL DEVICES & ACC 6 811151321 13 17000-2 Circuit Breaker, 15 A, DIN-Mount, 1 Pole 120VAC .. -_. . ,_v._· •• ,,_ . _____ . __ EUROTHERM CHESSELL E-6 MCP CHART RECORDER 39211/1/30001010/0010/20/0/1/0 4 13322-2.01-C 1010/11XXX1SV0050U050 Chart Recorder, Circular, 120VAC, 4-20mA Input, Nema 4 Panel Mount, 4-20mA Retrans Output, 7-Day 50-Divisions HOFFMAN E-6 MCP ENCLOSURE & ACC A907224FSD 6 17000-2.1 Enclosure, Free-StandingType 12 Two-Door Single Access, 90x72x24 HOFFMAN E-6 MCP ENCLOSURE & ACC A90P72F1 6 17000-2.1 Enc!osure Backpanel, 78x68 -----.... ._--_._--- HOFFMAN E-6 MCP ENCLOSURE & ACC ABRKT6 6 17000-2.1 Fan ~~_a~~_et:.!~~~nti~~ Fans A6AX_F_N_I_N_2 ____________________________ ~------------__________________ _ HOFFMAN E-6 MGP ENCLOSURE & ACe 2 AFLT64 6 17000-2.1 Enclosure Louver Plate Kit Filter, 4.45x6.25, for A72H3724FS Enclosure HOFFMAN E-6 MCP ENCLOSURE & ACC AGARD6 6 17000-2.1 Fan Finger Guard, for Fans A6AXFN/N2 Welillesiluy. October 16, 2002 MAIN CONTROL PNL. Page2of5 l' Mallufacturer Dwg IllstlDevice Tag Qty Part # Sub Sect Spec Sect Remarks l' AI"ea / Locatioll: GENERA TOR /CONTROL ROOM Equipt / Pallel: MAIN CONTROL PNL HOFFMAN E-6 MCP ENCLOSURE & ACC 1 APA6AXFN 6 17000-2.1 ATEMNO 6 17000-2.1 HOFFMAN E-6 MCP ENCLOSURE & ACC 2 AVK64 6 17000-2.1 Enclosure Louver Plate Kit, 7.88x7.50, for A72H3724FS Enclosure HOFFMAN E-6 MCP ENCLOSURE & ACC T-EG6UL12 6 17000-2.1 Enclosure Exhaust Grill, For UL Type 12 ------------------- IDEC E-7 MCP GENERAL PURPOSE RELAYS 15 RH2B-UL-AC120V 11 17000-2.19 Relay, 2-Pole, 120 Volt -. ~'--_. ----_ .. _---- IDEC E-7 MCP GENERAL PURPOSE RELAYS 24 RH4B-UL-AC120V 11 17000-2.19 Relay, 4-Pole, 120 Volt ... ~... _. . '---'--'-- IDEC E-7 MCP GENERAL PURPOSE RELAYS 15 SH2B-05 11 17000-2.19 Socket, Relay, 2-Pole .. . -_. --_.---... ' ---_ .. _---. IDEC E-7 MCP GENERAL PURPOSE RELAYS 24 SH4B-05 11 17000-2.19 Socket, Relay, 4-Pole . .. -, -.--. IDEC E-7 MCP TIME DELAY RELAYS 5 RTE-P11-AC120V 11 17000-2.21 Relay, Timer On-Delay, Pin-Type terminals, DPDT 10A Rated Contacts, 120VAC/1.6VA Coil, O.1sec to 10min Time Range -----------------------------------------------------------~-------------------IDEC E-7 MCP TIME DELAY RELAYS 11 17000-2.21 Relay, Time Delay, Pin Type, Off-Delay, 120 Volt --_. ---.. _ .. ---------_.----------------------'---------------------------------- IDEC E-7 MCP TIME DELAY RELAYS 11 17000-2.21 Relay Socket, 2-Pole 8-Pin Screw Terminal IDEC E-7 MCP TIME DELAY RELAYS 11 17000-2.21 E-6 MCP ENCLOSURE & ACC 17000-2.1 LEVITON E-6 MCP ENCLOSURE & ACC 17000-2.1 RJ11 Phone Jack LEVITON, E-6 MCP ENCLOSURE & ACC 17000-2.1 RJ45 Phone Jack L!=VITON E-6 MCP ENCLOSURE & ACe 6 17000-2.1 Duplex Receptacle, GFCI, 125Vacl15A, Ivory -------' --.-------.----"'--~-----------------------------------,---- LEVITON E-6 MCP ENCLOSURE & ACe 6 17000-2.1 Decora Wall pi ate , 1-Gang/1-Decora, SS _" ---------.-------------------------------------- LEVITON E-6 MOP ENCLOSURE & Ace 6 17000-2.1 Wetillesdtly, October 16, 2002 Page30f5 Mil/wj'lletm'er Dwg l11StlDevice Tag Al'ea / Locatio,,: GENERA TOR /CONTROL ROOM Equipt / PQlzel: MAIN CONTROL PNL LEVITON E-6 MCP ENCLOSURE & ACC LITHONIA E-6 MCP ENCLOSURE & ACC Lamp, Fluorescent, 120 VAC, 36" Qty Part# S126 F30T12CW -------------------------------------------------LITHONIA E-6 MeP ENCLOSURE & ACC S130120LPF Light Fixture, 120Vdc 30W, 36" Long, Low Power Factor ---~~-----------------------------------------------LlTTELFUSE E-7 MCP ELECTRICAL DEVICES & ACC 6 235,125 12 239.001 MCP ELECTRICAL DEVICES & ACC 239.002 MCP ELECTRICAL DEVICES & ACC 2 239.003 LlTTELFUSE E-7 MCP ELECTRICAL DEVICES & ACC 3 239.004 Fuse,5X20 Slow Blow 4 AMP @ 250V , , ., .. -_ ..... '----_. .----------------------------------------------- LlTTELFUSE E-7 MCP ELECTRICAL DEVICES & ACC 2 239.005 Fuse,5X20 Slow Blow 5 AMP @ 125V ~,~ ,..---------~------ MALLORY E-6 MCP ANNUNCIATOR SYSTEM SC110N Horn, Sonalert Continuous Tone, Panel Mount, 30VDC/120VAC ----------------------------------------------------------NEWPORT ELECTRONICS E-6 MCP DIGITAL FLOW INDICATOR 1 205-EAI,R,CO Digital Indicator, 3.5" w/ Full-size Digits, 3/64 DIN Case, 4-20mA Process Signal Input w/ Excitation Output, Standard Red LED, 115Vac Power _ _ ._._ ' •• __ ••• 4_R ______ _ NEWPORT ELECTRONICS E-6 MCP DIGITAL LEVEL INDICATOR 205-EAI,R,CO Digital Indicator, 3B' wI Full-size Digits, 3/64 DIN Case, 4-20mA Process Signal Input wI Excitation Output, Standard Red LED, 115Vac Power -• ,_ __ • __ Or _. ____ _ OPT022 E-7 MCP OPTO 22 TELEMETRY MULTIPLEXER AC7A SNAP RS232-RS422/485 Converter, 120VAC i" Sub Sect Spec Sect Remarks .., 6 17000-2.1 17000-2.1 6 17000-2.1 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 3 17000-2.12 8 17000-2.23 8 17000-2.23 12 17000-2.14.1 ., "'-"_. _ ... _-,-_._---_. __ . ---------------------------------------,.-------------------------------------------- OPTO 22 E-7 MCP OPTO 22 TELEMETRY MULTIPLEXER 1 B3000 12 17000-2.14.1 SNAP A~alo~~ig~~_~~.n, MisticlOPt_im_u-'-,x_P_r_o_to_c_ol ______ ---,,--____ -------------___________________________ _ OPT022 E-7 MCP OPTO 2~ TELEMETRY MULTIPLEXER 2 SNAP-AIV 12 17000-2.14.1 SNAP 2-Channel Analog Input Voltage M.:.o:..::d:..::u:..::le.:" ..,:+I_-1.:,:0:..::V:..::d:..::c-, ________________ '--_______________________________ _ OPT022 E-7 MCP OPTO 22 TELEMETRY MULTIPLEXER 1 SNAP-B12Mc 12 17000-2.14.1 SNAP 12-Module Rack, wI Extra Terminal Block for Field Wiring ......... ---.-------------,---." OPTO 22 E-7 MCP OPTO 22 TELEME;TRY MULTIPLEXER 7 SNAP-IAC5 12 17000-2.14.1 SNAP 4-Channel AC Input Module, 90-140Vac, 5Vdc Logic -------------------------------------------------------------------------------------OPT022 E-7 MCP OPTO 22 TELEMETRY MULTIPLEXER SNAP-PS5 12 17000-2.14.1 SNAP Power Supply, Single Rack, 11 OVacl5Vdc 4A In/Out .,.:::.::~ :.:;-:--:7:;-;::.~;:.;::,~::;,.:::.";:,~;;:~.::; ... ~..t';;;;~::_;;::-, ... ::;,~::.:::,_::::_= .• ::_::,_::::=":;;;,,::::.::::::?_=_:::::_=_::::::::_::::;;:_===:::::::::====:::::::::::::::::::::::::::::==:::::::::::::::==:::::==:::::==:::=:::::::::::=::::==:::==:::::== Weilllesiluy, October 16,2002 MAIN CONTROL PNL Page 4 of5 Mallltjiu:tllrer Dwg IllstlDevice Tag Are" I Location: GENERA TOR /CONTROL ROOM Eqllipt I P'lIle/: MAIN CONTROL PNL OPT022 E-7 MCP OPTO 22 TELEMETRY MULTIPLEXER SNAP 110 Module Jumper Straps, 1 Row of 4 jumpers wI common Tab, for 1 Module -------"- OPTO 22 E-7 MCP OPTO 22 TELEMETRY MULTIPLEXER SNAP I/O Module Wire Strap. to daisy-chain between 4 110 Mod Jumper Straps ~--. -. ... .-... --.-._---- PANDUIT E-7 MCP ELECTRICAL DEVICES & ACC Wireway Cover, 2", Per Ft. PANDUIT E-7 MCP ELECTRICAL DEVICES & ACC Wireway Cover, 3". Per Ft. _.-_. _. -._---------- PANDUIT E-7 MCP ELECTRICAL DEVICES & ACC Wireway, 2x4, Per Fi. PANDUIT E-7 MCP ELECTRICAL DEVICES & ACC Wireway. 3x4, Per Ft. POWER-ONE E-8 MCP UPS SYSTEM & POWER SUPPLlY ,. Qty Part# Sub Sect Spec Sect Remarks 10 SNAP-STRAP 12 17000-2.14.1 10 S NAP-WI RESTRAP 12 17000-2.14.1 30 C2LG6 13 17000-2 30 C3LG6 13 17000-2 30 E2x4LG6 13 17000-2 30 E3x4LG6 13 17000-2 F24-12-A 14 17000-2.11 ~.~/DC Powe~ ~~~~~: __ L~_~~~_120Va:.::.c..::in.2,.:::.2~4V:...d=C/.:...::12=A:....:.S::.:in~g:.:le.....:0::.:u::.:t~pu=t~ _____________________________________________ _ RACO E-7 . MCP AUTODIALER VSS-1!) 12 17000-2.14.4 RACO Verbatim Autodialer, 105-135Vac, 1_6_D_ry:.-.C_o_n_ta_c_tl_n:..pu_ts ________________________________________________ _ RONAN E-6 MCP ANNUNCIATOR ;:>YSTEM 18 6-6X12-2000· 3 17000-2.12 Annunciator Cabinet, 6 Window Hi X 6 Modules, Wire for 36 Positions, Consists of 18 Modules (3X6) RONAN E-6 MCP ANNUNCIATOR SYSTEM 34 F3A-1-0-00D 3 17000-2.12 Annunciator Alarm Modules, Sequence F3A-1. 24VDC Field Dual Aux Contacts (Form D) RONAN E-6 MCP ANNUNCIATOR SYSTEM 1 FHD24-000 3 17000-2.12 Annunciator Flasher Hom Module RONAN E-6 MCP ANNUNCIATOR SYSTEM 17 LM2-24 3 17000-2.12 Annunciator Lamp Module, 2-Windows/Module -------------------------------------------------------------------------------------------------------------------------RONAN E-6 MCP ANNUNCIATOR SYSTEM 1 RF-24-1 3 17000-2.12 Annunciator FilterModule RONAN E-6 MCP ANNUNCIATOR SYSTEM 1 X12P4 3 17000-2.12 Annunciator Pushbutton Module. 4-Functions .-----------------------------------~----~------------------~--------------------------~----------------SAN DIEGO ENGRAVING E-6 MCP ENCLOS,-!RE & ACC 1 Engraving 001 17000-2.1 _~~~~~.V!.~~_~~~~dule-SeeA.::tta:.:c::.:h.::ed:..:;:fo::.r .::D.::et:.:a:.iI ________________________________ -----------------------------------------------___________ _ WARRICK CONTROLS (GEMS E-7 MCP INDUCTION RELAYS 2 2800-101 11 17000-2.20 SENSORS) MQisture Detector, Induction Type, 115VAC Coil. 1 NO & 1 NC Contacts, Nema 1 End .. _ .... ',.,"'-l' • .., ..... _.p,,;:..~.-:,::-......... ,-..1..t>~~ ..... ,.,;::.:.~"u;:_.:~_=~ =--~ _______ ..,.... ____ _ Wedllesday, October 16, 2002 MAIN CONTROL PNL PageS ofs" .. , SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST CHECKLIST REPORT FOR MAIN GONTROL PANEL The following checklist is to be utilized for documenting completion of the required panel inspections and tests. Following are the system hardware and software inspections and tests to be performed: Visually inspect nameplates, tags, and other engraving. Visually inspect wire sizes, wire numbering, and color-coding. Visually inspect for proper wiring practices , and grounding. Visually inspect enclosure finish and color Visually inspect for general neatness and appearance. Verify that all elements in the system are properly powered from the demarcation points within the enclosure. Check panel wiring. Utilize the panel construction drawings for this procedure. Signature -Rockwell Electric, Inc. Representative Signature -Owner/Owner's Representative Date Date 1 • SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST I/O REPORT FOR MAIN CONTROL PANEL Each input and output point for the programmable logic controllers shall be verified for electrical and logical connection. The I/O list for the programmable logic controllers shall be used for this test. Each discrete input point shall be connected to a simulator at the panel demarcation and the state shall be changed. Analog input signals shall be tested using a simulator at the point of demarcation. Signals shall be input at 0, 25%, . 50%, 75%, and 100%. If any point is entirely wired within a cabinet (i.e. a switch, push- button, or light), the appropriate device shall be used for verification. Rockwell Electric, Inc. has verified that the I/O associated with this panel has been tested for electrical and logical connection. Signature -Rockwell Electric, Inc. Representative Date Signature -Owner/Owner's Representative Date j. • •• SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST PANEL WIRING REPORT FOR MAIN CONTROL PANEL The panel wiring shall be tested to the construction drawings supplied. Rockwell Electric, I nco has verified that all panel wiring associated with this panel has been checked. Signature -Rockwell Electric, Inc. Representative Date Signature -Owner/Owner's Representative Date ITEM SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST CORRECTIONS REPORT FOR MAIN CONTROL PANEL MODIFICATIONS OR CORRECTIONS CORRECTIVE ACTION TAKEN Rockwell Electric, Inc. has verified that the corrective actions listed above have been completed. Signature -Rockwell Electric, Inc. Representative Date -. SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST SECTION 3 FACTORY TEST REPORT BUBBLER CONTROL PANEL I &C Bill of Materials SAND SHELL LIFT STATION CITY OF CARLSBAD, SAND SHELL LIFT STATION Mallufacturer Dwg IllStlDevice Tag Are" / Location: GENERA TOR /CONTROL ROOM Equipt / Panel: BUBBLER CONTROL PNL AMETEK E-9 BCP PRESS & DP GAUGES Pressure Gauge, 2" Dial, 1/4" NPT Center Back Connection, 0-30 PSI AMETEK E-9 BCP PRESS & DP GAUGES Pressure Gauge, 2" Dial, 1/4" NPT Center Back Connection, 0-60 PSI Qty Part# 1X758 1 1X760 --------------------------------------------------------ASCO E-9 BCP SOLENOID VALVES 8262G263 Solenoid Valve, 2-Way, 1/4", 120VAC -, --~--~----.~--~"------ ASCO E-9 BCP SOLENOID VALVES 8320G174 Solenoid Valve, 3-Way, 1/4", 120VAC . --' . --.. _._. -_. __ . ---------------------------------------------------------------- BARKSDALE E-9 BCP PRESSURE SWITCH 3 D1S-A80SS Pressure Switch, 0-80 PSI .-. '~""--.-. __ .. -._--- CONTROL AIR, Inc. E-9 BCP AIR FILTER/REGULATOR 300-BAG Air filter Regulator, Instruments .--_ .... ---_. __ .. -... _-------------------------------- CONTROL DEVICES, Inc. Check Valve, Air, Bronze E-9 BCP CHECK VALVES 2 CB-25 --.... ------------------------------------------------ CUTLER-HAMMER E-9 BCP ELECTRICAL DEVICES & ACC 10250T1 Selector Switch Operator Contact Block, 1 NOli NC ------------------------------------------------------------------CUTLER-HAMMER E-9 BCP ELECTRICAL DEVICES & ACC 1 10250T20KB Selector Switch, Assembled, 2 Position Maintained, Black, 1 NO/NC Contact CUTLER-HAMMER E-9 BCP ELECTRICAL DEVICES & ACC 10250T30!3 Pushbutton, Mon~e~:r:~' _wI .~. !,!9~1_~~_Contact Bloc~~ack_, _N_E_M_A_4_X. ___________________________ __ CUTLER-HAMMER E-9 BCP ELECTRICAL DEVICES & ACC 1 10260T37NG Indicating Light, Glass Lens, Green, 120 VAC, PIT, NEMA 4X -----.... -.. ----,----._----.. _._--------------------------------------------------------- CUTLER-HAMMER E-9 BCP ELECTRICAL DEVICES & ACC ? 10250T37NR Indicating Light, 'Glass Lens, Red, 120 VAC, PIT, NEMA 4X ----- DWYER E-9 BCP FLOW METER VFA-2-BV Flowmeter, Air, 1/4" VISI-FLOAT DWYER E-9 BCP PRESS & DP GAUGES 1 2150 D~ffer~nt!al Pressure gauge, 150" H2'-O _________________________________ _ EDWARDS E-9 Transformer, 120VAC In, 24VAC Out, 40VA BCP ENCLOSURE & ACC EDWARDS-599 " ,. '" • Archer Westerll COlls/rue/ors 8775 Aero Drive, Suite 335 Sail Diego, Ca 92123 Sub Sect Spec Sect Remarks 5 17000-2.13 5 17000-2.13 5 17000-2.13 5 17000-2.13 5 17000-2.13 5 17000-2.13 5 17000-2.13 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 5 17000-2.13 5 17000-2.13 17000-2. 13-B .. _.-.. _-". --_ ......... ,--_._--¥"._-------_.--_._------------. --------------- <or •• "I ................ ·.~~~,· ...... .::..r~ul.1.\.l!U..l.r. ... \oO.:~ ........ ~:i.~~.~, ~_~. _________ ~ Wet/nest/flY, October 16, 2002 BUBBLER CONTROL PNL Pagelof4 Mallufacturer Dwg InstlDevice Tag Qty Part# Sub Sect Spec SeCt Remarks Area / Locatio,,: GENERATOR /CONTROL ROOM Efillipt / Panel: BUBBLER CONTROL PNL EG CONTROLS (MICROMAC) E-9 BCP LEVEL CONTROLLER Pump Controller, 24VDC Pwr Only, Duplex Pump Operation, 0-35FT Range __ •• '_,.RR _ .,_ ••••• _._. __ ~.~ ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 1 2300 2 101598.26 Terminal Block DIN Rail, PR5, Prepunched, 6 ft . . ~~--~------------------------------------------------------ENTRELEC E-9 Bep ELECTRICAL DEVICES & ACC 6 103002.26 Terminal Block End Stop, 6 m~~m~ _____________________________________ _ ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 40 115116.07 ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 4 115657.25 Fuse Block, Grey, Bmm, Type M4IB.SF .-... -..... _.--_._-._---------------------------------------------------- E-9 BCP ELECTRICAL DEVICES & ACC 2 116951.15 ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 4 118368.16 Terminal Block End Section, Grey, 6-10 mm TB's --------------------------------------------ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 2 165113.16 Terminal Block, Ground, GreenlYellow, 6mm ~-------------------------------------ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 2 165275.00 Terminal Block, Isolated Ground, Yellow, 6mm --------------------------------------------ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 5 173523.11 Fuse Block Comb Type Jumper Bar, 10 Pole ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 4 174784.20 . Terminal Block Jumper Bar, Universal, 2-Pole -~------------------------------------------------------ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 4 176679.10 Terminal Block Jumper Bar, Preassembled, 10 Poles, for 10mm TB -----------------------------------------------------------ENTRELEC E-9 !3CP ELECTRICAL DEVICES & ACC 1 236000.04 Terminal Block Markers, RCT61o, 6x10mm Top Marking, 1 Card 1100 Markers (Old Part No. 256000.04) .. . ... ,-... ------ ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACC 2 811146221 Circuit Breaker, 10 A, DIN-Mount, 1 Pole 120VAC -. -. -.. _--_.---_.-.. . ---~-----------------------,------------------------- ENTRELEC E-9 BCP ELECTRICAL DEVICES & ACe B11151321 Circuit Breaker, 15 A, DIN-Mount, 1 Pole 120VAC ... -.-------.-.---------------------~----------------------------------- GRAINGER E-9 BCP AIR COMPRESSORS & ACC 4 4C875 Compressor Mount Vibration Isolator HOFFMAN E-9 BCP ENCLOSURE & ACC A603612LP Enclosure, 60x36x12, Nema 12 --~--------------------------------------------------- HOFFMAN E-9 BCP ENCLOSURE & ACC A60P36 Enclosure Back Panel, 57x33 10 17000-2.13 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 13 17000-2 5 17000-2.13 6 17ooo-2.13~B 6 17000-2.13"B ---:-:--~;-~.:-:.-::~=; ... _ ....... t::" •••• ,~ .... ' ..... ' • ..:.t •• ~~~., ........... .!"---.,, .... , .. --"-,-............,--............ ~ ------.. -----:::--~ ... -.--... ~~-'----';::-----:::-~>' ---------~---------"-- Wetlnestlay, October 16, 2002 BUBBLER CONTROL PNL , .". Page2of4 Malllijactltrer Dwg IlIstlDevice Tag A,.ea / Location: GENERA TOR /CONTROL ROOM Equipt / PaJlei: BUBBLER CONTROL PNL HOFFMAN E-S BCP ENCLOSURE & ACC Enclosure Louver Plate Kit Filter, 4.45x6.25, for A72H3724FS Enclosure HOFFMAN E-9 BCP ENCLOSURE & ACC Enclosure Louver Plate Kit, 7.88x7.50, for A72H3724FS Enclosure Qty P(lrt# Suh Sect Spec Sect Remarks 2 AFLT64 6 17000-2.13-B 2 AVK64 6 17000-2.13-B ----------------------------------------------------------------IDEC E-S BCP RELAYS 2 RH2B-UL-AC120V 11 17000-2.13 Relay, 2-Pole, 120 Volt --_. ------------- IDEC E-S BCP RELAYS 4 RH4B-UL-AC120V 11 17000-2.13 RelaY,4-Pole, 120 Volt ------.-____ H. IDEC E-9 BCP RELAYS RR2KP-U-AC120V 11 17000-2.13 Relay, Latching, DPDT, 120 Volt . --.----------- IDEC E-9 BCP RELAYS 4 RTE-P11-AC120V 11 17000-2.13 Relay, Timer On-Delay, Pin-Type terminals, DPDT 10A Rated Contacts, 120VAC/1.6VA Coil, O.1sec to 10min TIme Range -_ ... _. ----------.--.-.--- IDEC E-9 BCP RELAYS 2 SH2B-05 11 17000-2.13 Socket, Relay, 2-Pole IDEC E-9 BCP RELAYS 4 SH4B-05 11 17000-2.13 Socket, Relay, 4-Pole IDEC E-9 BCP RELAYS 4 SR2P-05 11 17000-2.13 Relay Socket, 2-Pole 8-Pin Screw Terminal LEVITON E-9 BCP ENCLOSURE & ACC 1 6599-1 6 17000-2.13-B Duplex Receptacle, GFCI, 125Vac/15A, Ivory .. _ ..... -., .---.--------------------------------------------- LEVITON E-S BCP ENCLOSURE & ACC 84401-40 6 17000-2.13-B Decora Wallplate, 1-Gang/1-Decora, SS L1TTELFtiSE E-S BCP ELECTRICAL DEVICES & ACC 2 235.125 13 17000-2 Fuse,5X20 Fast Acting 0.125 AMP @ 250V ..... -------.. -------. .------------------------------------- lITTELFUSE E-9 BCP ELECTRICAL DEVICES & ACC 2 239.002 13 17000-2 Fuse,5X20 Slow Blow 2 AMP @ 250V NUPRO E-9' BCP NEEDLE VALVES 5 B-4-JN-PM 5 17000-2.13 Needle Valve, Screwed Bonnet PANDUIT E-9 BCP ELECTRICAL DEVICES & ACC 24 C2LG6 13 17000-2 Wireway Cover, 2", Per Ft. PANDUIT E-S BCP ELECTRICAL DEVICES 8. ACC 24 E2x4LG6 13 17000-2 Wireway, 2x4, Per Ft. --_ .... _-_._-_._---- POWER-ONE E-7 BOP 24VDC POWER SUPPLY HC24-2.4-A 14 17000-2.15 AC/DC Power'Supply, Linear 120Vac in, 24VdcJ2.4A Sinf,l'e Output POWER-STRUT E-S BCP AIR COMPRESSORS & ACC 2 PS-732-10-EG 5 17000-2.13 ~ t;. ,~ k Compressor Shelf Bracket, 10.5" Long, Electro Galvanized '. :, :.-• :::.::::;-:,:: ~~r. .... ...,.~~... ..;"I:.:~_::~::~=~::.;;:::~;;:::;:;:=;;;;:: .. _;:;:· =~;;:::::.:::::;;~_::.::::::;;;;=:::;:;:::::::::::::::::::::::::::::::::::::::::;:;:::::::::::;:::=:::::::=::::::::::::::::::::::::::::::::::::::::::::::::::::==::;::::::::::::::::::::::::::::::::::: .WelilJesliuy, October 16, 2002 BUBBLER CONTROL PNL Page30f4 M allujactllrer Dwg IJlStiDevice Tag Area / Locatio,,; GENERA TOR /CONTROL ROOM Eql(ipt / Pallel: BUBBLER CONTROL PNL POWER-STRUT E-9 BCP AIR COMPRESSORS & ACC Compressor Shelf Bracket, 8.5" Long, Electro Galvanized SAN DIEGO ENGRAVING E-9 8CP ENCLOSURE & ACC Qty Part# 2 PS-732-8-EG Engraving 001 Engraving Schedule-See Atta:..::c.:..:h~ed~fo.:..:r....:D=-e.:..:ta=i1 ___________________________________ _ SAN DIEGO ENGRAVING E-9 BGP ENCLOSURE & ACC Engraving 001 Engraving Schedule-See Attached for Detail --------------------------------------------THOMAS INDUSTRIES E-9 8CP AIR COMPRESSORS & ACC 2 LGH-106-H02 Air Compressor, 1/12 HP, 115Vac/50-60Hz, Horizontal Tank Mounted .. . -..... -~-" .. -. --.----- TIME MARK E-9 BCP RELAYS 2610-120 Relay, Alternating, DPDT, 120Vac . . ~--. -.--_._--_._-------_. TIME MARK E-9 BCPRELAYS , 1 51X016 Relay Socket, Alternating, ii-Pin " II Sub Sect Spec Sect Remarks '" 5 17000-2.13 17000-2.13-8 17000-2.13-8 5 17000-2.13 11 17000-2.13 11 17000-2.13 ", •• I~I~ " ',~\r.-~' ~" ... .."..·=:.>.,.I'j'r •• _'I1.~<h..'Ir=""""""~.-I<>t~-.... ~"""'~~:;_..a.~~...,. .. ~~" __________________________________________ ~ ________ .... _____ • Wetl"esllllY, October 16,2'002 BUBBLER CONTROL PNL Page4of4 SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST CHECKLIST REPORT FOR"BUBBLER CONTROL PANEL The following checklist is to be utilized for documenting completion of the required panel inspections and tests. Following are the system hardware and software inspections and tests to be performed: Visually inspect nameplates, tags, and other engraving. Visually inspect wire sizes, wire numbering, and color-coding. Visually inspect for proper wiring practices and grounding. Visually inspect enclosure finish and color Visually inspect for general neatness and appearance. Verify that all elements in the system are properly powered from the demarcation points within the enclosure. Check panel wiring. Utilize the panel construction drawings for this procedure. Signature -Rockwell Electric, Inc. Representative Signature -Owner/Owner's Representative Date Date SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST I/O REPORT FOR BUBBLER CONTROL PANEL Each input and output point for the programmable logic controllers shall be verified for electrical and logical connection. The I/O list for the programmable logic controllers shall be used for this test. Each discrete input point shall be connected to a simulator at the panel demarcation and the state shall be changed. Analog input signals shall be tested using a simulator at the point of demarcation. Signals shall be input at 0, 25%, 50%, 75%, .and 100%. If any point is entirely wired within a cabinet (i.e. a switch, push-button, or light), the appropriate device shall be used for verification. Rockwell Electric, Inc. has verified that the I/O associated with this panel has been tested for electrical and logical connection. Signature -Rockwell Electric, Inc. Representative Date Signature -Owner/Owner's Representative Date SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST PANEL WIRING REPORT FOR BUBBLER CONTROL PANEL The panel wiring shall be tested to the construction drawings supplied. Rockwell Electric, Inc. has verified that all panel wiring associated with this panel has been checked. Signature -Rockwell Electric, Inc. Representative Date Signature -Owner/Owner's Representative Date SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST FACTORY TEST CORRECTIONS REPORT FOR BUBBLER CONTROL PANEL ITEM MODIFICATIONS OR CORRECTIONS CORRECTIVE ACTION TAKEN Rockwell Electric, Inc. has verified that the corrective actions listed above have been completed. Signature -Rockwell Electric, Inc. Representative Date SAND SHELL LIFT STATION CITY OF CARLSBAD INSTRUMENTATION & CONTROL HARDWARE FACTORY ACCEPTANCE TEST SECTION 3 FIELD INSTRUMENT BILL OF MATERIALS I &C Bill of Materials SAND SHELL LIFT STATION CITY OF CARLSBAD;SAND SHELL LIFT STATION Malllifactllloer Dwg lllst/Device Tag A,oeo / Location: GENERA TOR /CONTROL ROOM Equipt / Panel: INTRUSION SYSTEM ADEM CO NA INTRUSION KEYPAD Intrusion System Remote Keypad, 32 Character 2-Line LCD Display. Backlite Keys. SQUARED E-3/7 INTRUSION DOOR LIMIT SWITCH Qty Part# 6139 9007-C54B2 ,.) it " Archer Westem COllstrui:tors 8775 Aero Drive, Suite 335 Sail Diego, Ca 92123 Sub Sect . Spec Sect Remarks 9 16726 9 17000-2.22 Limit Switch. Lever ARM Turret. CI_as_s_9:.,.0_0._7..:. • .:..F..:.o_rm.:.:.....,C _________ . _____________________________________________ _ Square D E-3/7 INTRUSION DOOR LIMIT SWITCH 9007-HA-1 9 17000-2.22 Limit Switch. Adjustable ARM. Class 9007 ---------------------------------------------------------------------------------------------------------------------------- Area / Locatio,,; OFFICE AREA Eqllipt / Pallel: MODEM RACKMOUNT BLACK BOX NA MODEM -RACKMOUNT 1 MD1000C 12 17000-2.14.2 . Modem. Model 3600 Rackmount Card " .. ---..... _ ...... -_._------------------------------------------------------------------ ~ ....... " _"· ... ~_M ... ·_~"'_.~· ~_ ..... =-.. =~,,~~. =.,=,. __ ~~_~~__=_::__::_::_::~-.------:----"'-- WCt'"CSt'uy, October 16, 2002 MODEM RACKMOUNT , . Pagelof2 ). t MaJlufacturel' DJVg IllstiDevice Tag Qty Part# Sub Sect Spec Sect Remarks r Area / Locatioll: WET WELL AREA Equipt / Pallel: DRYWELL FLOOD SWITCH GEMS E-4 LSH-01 1 43765 7 17000-2.31 Level Switch, Model LS-270, 20VA, 1 N.O. Cntct _ .. --.--------------- Area / Location: WET WELL AREA Equipt / Pallel: FLOWMETER CONTROLOTRON E-4 FE/FIT-01 1010N1 7 13322 Flow Meter Computer " .. -"._-,------- CONTROLOTRON E-4 FE/FIT-01 .1 1010NFM-3 7 13322 Flow Computer Manual .-.. --. --_ .. _.------ CONTROLOTRON E-4 FE/FIT-01 1 1011 NFPS-01 7 13322 Flow Meter Transducer CONTROLOTRON E-4 FE/FIT-01 1012BN-1 7 13322 Flow Meter Space Bar '.----.--.------- CONTROLOTRON E-4 FE/FIT-01 1 1012CNW-50 7 13322 Flow Meter Submersible Cable Assembly, 50FT .. .--. ". --.. _ ....... '"-_._---- CONTROLOTRON E-4 FEIFIT-Oi 1012FN-PO 7 13322 Flow Meter Mounting Frame, 1 Pair .. _--.-----.--.. Area / Location: WET WELL AREA E9uipt / Pallel: LEVEL SWITCHES FLYGT E-4 LSHH-01 5828831 7 17000-2.30 Float Switch, Model ENM10, 60' Cable, SPOT 16A at 250Vac Contacts FLYGT E-4 LSLL-01 5828831 . 7 17000-2.30 Float Switch, Model ENM10, 60' Cable, SPOT 16A at 250Vac Contacts ,--.. _. , ... " -~ ---"-~----.--- .," 1.1 ; ",',.,' ",".OJ .~~ ..... ·_·-._ ........... ,'_ .... ....u:.-... r."._ ...... _t.o:,~..A\ .. ~,:: .... .......tuIA.!_-.....-~,~, .~ __ , ~, _._ .... _,_·_v= .. " __ ~, ~~ ....... _____ ............... ___ ...-__ ""-_ ...... ~ ____________ _ Welilles/lay, October 16, 2002 LEVEL SWITCHES Pagelofl