HomeMy WebLinkAboutCT 05-09; BRESSI RANCH; ROUGH GRADE COMPACTION REPORT; 2007-06-22C-r o—o"j ROUGH GRADE COMPACTION REPORT PROPOSED BUSINESS PARK Bressi Ranch Lots 33-39, Planning Area 5 Carlsbad, California for St. Croix Capital SOUTHERN I n CALIFORNIA 'W — GEOTECHNICAL 1 June 22, 2007 mr A California Corporation St. Croix Capital I 406 9th Avenue, Suite 309 San Diego, California 92101 Attention: Mr. Jim Jacob Subject: Rough Grade Compaction Report Proposed Business Park Bressi Ranch Lots 33-39, Planning Area 5 Carlsbad, California Project No.: 07M132-1 Reference: Geotechnical Investigation, Proposed Business Park, Bressi Ranch Lots 33-37, Planning Area 5, SEC of Palomar Airport Road and El Fuerte, Carlsbad, California, prepared by Southern California Geotechnical, Inc. (SCG), dated March 3, 2005, SCG Project No. 05G109-1. Gentlemen: jIn accordance with your request, Southern California Geotechnical, Inc. (SCG) presents this Rough Grade Compaction Report which serves as a summary of the grading observation and testing performed by our personnel during remedial/rough gradin operations at the subject site. SITE DESCRIPTION The subject site is located within the recently mass graded Bresi Ranch Industrial Park which is located on the south side of Palomar Airport Road in the city of Carlsbad, California. The specific site is identified as Lots 33 though 39 within Planning Area 5. The site is bordered to the north by Palomar Airport Road, to the west by El Fuerte Street, and to the south and east by Gateway Road. The site is an irregularly-shaped parcel, approximately 16± acres in size. Site topography consists of gently sloping terrain, dipping downward to the southwest with approximately 30 feet of elevation differential across the site. The northern and western site boundaries are occupied by ascending 2h:lv slopes with a maximum heights of approximately 20 feet. I PROPOSED DEVELOPMENT The current phase of construction will generally be limited to the western half of the overall site. I The proposed development will consist of nine (9) buildings with total areas ranging from 6,000± ft2 to 11,000± ft2 Buildings D and E will share ,,a common wall The buildings will be one and two-story tilt-up concrete structures surrounded by asphaltic and Portland cement I concrete parking and drive areas. Thebüildings-will bésupported on conventional shallow foundations and slab-on-grade floors. Based on the planned construction, maximum column and wall loads are expected to be on the order of 60 kips and 3± kips per linear foot, respectively. The grading plan prepared by Partners Engineering indicates the fills of ranging from 2± to 10± I 22885 East Savi Ranch Parkway v Suite E v Yorba Linda, CA 92887-4624 voice: (714) 685-1115 v fax: (714) 685-1118 v www.socalgeo.com 1 feet were required to establish the planned subgrade elevations I development area. This estimate is exclusive of any overexcavation placement necessary for the recommended remedial grading activities. within the proposed and subsequent 1911 PREVIOUS STUDIES SCG previously conducted a geotechnical investigation report for the proposed development. The results of this investigation are presented in the above referenced report. As part of this study, SCG reviewed the previous geotechnical reports and mass grading reports for Planning Area 5. The SCG subsurface exploration conducted for this project consisted of eight (8) borings advanced to depths of 21/2 to 191/2 ± feet below the existing site grades. Artificial fill soils were encountered at the ground surface at five of the eight boring locations. These fill soils extended to depths of 11/2 to 31/2± feet below existing grade. The fill soils encountered in the borings generally consisted of medium stiff to very stiff, sandy clays, and dense clayey sands. The fill soils possessed moderately high strengths, moisture contents near or above optimum, and based on their color mottling and composition, appeared to be well mixed. Bedrock was encountered either at the ground surface or beneath the fill soils at all of the boring locations. The bedrock encountered at this site consisted of Tertiary age Santiago formation, which is comprised of dense to very dense sandstone with some zones of claystone and siltstone. Bedding within the Santiago formation on site is generally massive with no significant planes of weakness or discontinuities. The sandstone unit is typically light gray in color, contains moderate iron oxide staining, and is comprised of weakly cemented silty fine sand. The siltstone unit is typically light gray to gray in color, contains moderate iron oxide staining, and is comprised of fine sandy silt. The claystone unit is typically dark gray to gray green in color, contains some shell fragments, gypsum veins, and is comprised of silts and clays. Based on the expansive potentials and differing strengths of the engineered fill and bedrock, and in order to provide for a new layer of structural fill that will help mitigate the potential cut/fill transitions, it was recommended that remedial grading be performed within the proposed building pad areas. The building pad areas were recommended to be overexcavated to a depth of at least 3 feet below the proposed pad grade. It was also recommended that the foundation influence zones for the new buildings be overexcavated to a depth of 3 feet below the foundation bearing grades. SUMMARY OF EARTHWORK OPERATIONS AND TESTING Rough grading operations documented in this report were initiated on May 7, 2007 and were completed on August 9, 2006. The building pad areas were overexcavated in accordance with the recommendations presented in the referenced geotechnical report. This resulted in the building areas being overexcavated to depths ranging from 6± to 13± feet below the proposed pad grades. The limits of overexcavations were extended laterally at least 5± feet beyond the building and foundation perimeters. The foundation influence zones for the proposed retaining walls located along the western and northern site boundaries were overexcavated to a depth of at least 2 feet below the foundation bearing grades, in accordance with the recommendations presented in the referenced geotechnical report. The exposed overexcavation subgrades were comprised of native bedrock material or the existing compacted fill soils. The exposed subgrade soils within the excavated building areas and in the low areas of the parking lot which were to SOUTHERN Bressi Ranch Lots 33-39 - Carlsbad, CA I BI1' CALIFORNIA Project No. 07M132-1 Page 2 GEOTECHNICAL 1 be filled were scarified to a depth of 10 to 12± inches, moisture conditioned, and recompacted. The prepared subgrades were noted to be firm and unyielding beneath the weight of the grading equipment and were approved for filling by an SCG field representative. The excavations were then backfilled with compacted structural fill to reach finished grades. Fill materials consisted of on-site and imported soils that were moisture treated and compacted in 6± inch thick lifts with fully loaded scrapers and a rubber tired dozer. The fill soils were compacted to at least 90 percent of the ASTM D-1557 maximum dry density. Structural fill compaction was tested by the Nuclear Method (ASTM D-2922-81) and referenced to maximum dry density values obtained by the Modified Proctor method (ASTM D-1557-91). Where density tests indicated less than the minimum specified compaction, the areas were moisture treated as necessary and recompacted until 90 percent of the ASTM D-1557 maximum dry density was achieved as indicated by retests. Locations indicating passing test results are indicated on the enclosed Density Test Location Plan, Plate 1. Moisture-density test results are indicated on Table 1, enclosed in this report. In addition, data regarding the soil types used as structural fill are presented on Table 2. LABORATORY TESTING Expansion Index Representative samples of the soils used for fill were obtained from the completed building pads for Expansion Index (El) testing. The expansive potential of the fill soils was determined in general accordance with Uniform Building Code (UBC) Standard 18-2. The results of the Expansion Index testing are as follows: Sample Identification Expansion Index Expansive Potential Building B 5 Very Low Composite: Buildings A, F, G 0 Very Low Composite: Buildings C, D, E, H, I 0 Very Low Based on the above test results, these soils have been classified as very low expansive. The foundation and floor slab design recommendations presented in the geotechnical report were made with respect to the presence of medium expansive on-site soils, therefore, no additional considerations with respect to expansive soils are considered warranted at this time. Soluble Sulfates The results of the soluble sulfate testing performed during our original geotechnical investigation indicated that the on-site soils possess negligible to severe concentrations of soluble sulfates, with regard to attack of subsurface concrete. Based on these results, specialized sulfate resistant concrete mix designs will be necessary. At a minimum, the UBC requires that all concrete which will come into contact with these soils incorporate the following characteristics: SOUTHERN Bressi Ranch Lots 33-39 - Carlsbad, CA I W,/CALIFORNIA Project No. 07M132-1 , _QpTEcHNicAL Page 3 I Cement Type: V (Five) I . Minimum Compressive Strength (f'): 4,500 psi Maximum Water/Cement Ratio: 0.45 I All structural concrete should meet the requirements of the Uniform Building Code and the American Concrete Institute. Additional samples of the soils used for fill were obtained from the completed building pads and were submitted for sulfate testing. The results of the additional testing will be documented in an addendum letter when they become available. CONCLUSIONS AND RECOMMENDATIONS I Geotechnical observation and testing of the rough grading activities indicate that the building pads have been suitably prepared, with grading activities conducted in accordance with recommendations presented in the original geotechnical engineering report and the local - building codes. The building pads are expected to provide adequate support for the intended structures which utilize foundations designed for a maximum allowable soil bearing pressure of 2500 lbs/ft2. The foundations, floor slab, and other improvements should be designed in accordance with the recommendations contained in the original geotechnical report referenced above. It is recommended that SCG be contacted to perform additional earthwork observation and testing during the following phases of the project: Foundation Excavation Utility Trench Backfill Retaining Wall Construction and/or Backfill Subgrade Preparation in New Pavement Areas Aggregate Base Placement in New Pavement Areas SOUTHERN Bressi Ranch Lots 33-39 - Carlsbad, CA CALIFORNIA Project No. 07M132-1 , GEOTECHNICAL Page 4 CLOSURE This opportunity to be of continued professional service is sincerely appreciated. Should you have any questions regarding this project, please contact us at your earliest convenience. Respectfully Submitted, SOUTHERN CALIFORNIA GEOTECHNICAL, INC. OFSS!O 0. 22194 Ju Y Exp- 12/3,11/08 e inara, GE 2294 QF Eku: nsity Test Location Plan, Plate 1 mmary of Field Density Tests, Table 1 mmary of Moisture-Density Relationships, Table 2 Distribution: (1) Addressee (3) TFW Construction, Attn: Jeff Weeks ,- SOUTHERN 8ressi Ranch Lots 33-39 - Carlsbad, CA ,P CA ... LIFORNIA Project No. 07M132-1 , ....EOTECHNICAL Page 5 .G - - - - - - - --- - - - - - - - - - - TABLE I SUMMARY OF FIELD DENSITY TESTS Test No. Date Elev. Test Soil Moisture Dry Density Relative Comments (ft) Location Type Content (Pct) Compaction (%) (%) 1 07-May-07 395.0 Building G A 14.9 103.1 91 BOX 2 07-May-07 398.0 Building G B 16.1 103.9 90 3 07-May-07 400.5 Building G B 16.7 105.5 91 BOX 4 07-May-07 400.0 Building G B 13.9 106.7 92 5 07-May-07 400.5 Building G B 16.4 104.2 90 BOX 6 08-May-07 401.5 Building G A 15.1 103.0 91 7 08-May-07 401.5 Building C A 15.6 103.8 92 8 08-May-07 402.5 Building G B 14.9 107.8 93 9 08-May-07 402.5 Building G B 14.3 105.2 91 10 09-May-07 403.0 Building G B 15.7 107.5 93 11 09-May-07 403.0 Building G B 14.9 105.3 91 12 09-May-07 403.5 Building G B 16.8 106.6 92 13 09-May-07 403.5 Building G B 15.1 107.9 93 14 10-May-07 402.0 Building F B 15.1 106.3 92 BOX 15 10-May-07 401.5 Building F B 17.5 103.7 90 BOX 16 10-May-07 404.5 Building C B 14.9 107.7 93 17 10-May-07 404.5 Building G B 15.7 105.3 91 18 10-May-07 404.0 Building A B 17.1 105.6 91 BOX 19 10-May-07 404.0 Building A B 17.8 104.1 90 BOX 20 10-May-07 403.5 Building A B 16.4 106.8 92 BOX 21 10-May-07 405.5 Building G A 17.6 105.1 93 22 10-May-07 405.5 Building G B 14.9 105.5 91 23 11-May-07 405.0 Building A 14.9 103.2 91 24 11-May-07 405.5 Building A A 16.7 105.9 94 25 11-May-07 403.0 Building F A 15.1 99.9 88 Fail: 90% Required 26 11-May-07 403.0 Building F A 15.7 102.7 91 Retest #25 27 11-May-07 400.0 Building F B 17.7 106.1 92 28 11-May-07 400.5 Building F B 17.3 105.3 91 29 14-May-07 401.5 Building F B 18.2 104.1 90 30 14-May-07 401.5 Building F B 17.6 105.3 91 31 14-May-07 403.5 Building F B 18.1 101.3 88 Fail: 90% Required 32 14-May-07 403.5 Building F B 17.7 102.5 89 Fail: 90% Required 33 14-May-07 403.5 Building F B 17.9 103.9 90 Retest #31 34 14-May-07 403.5 Building F B 17.7 105.0 91 Retest #32 35 15-May-07 405.5 Building F B 18.4 105.2 91 36 15-May-07 405.5 Building F B 18.1 105.0 91 37 15-May-07 404.5 Building B B 17.6 106.7 92 BOX 38 15-May-07 403.0 Building B B 18.6 103.9 90 BOX 39 15-May-07 404.0 Building C B 17.1 104.8 91 BOX 07M132-1 Bressi Ranch Lots 33-39 -- Carlsbad, California Page 1 - - - - - - - - - TIM I - - - - - - - - - SUMMARY OF FIELD DENSITY TESTS Test No. Date Elev. Test Soil Moisture Dry Density Relative Comments (ft) Location Type Content (pct) Compaction (%) (%) 40 15-May-07 404.5 Building C B 16.6 106.2 92 BOX 41 15-May-07 406.0 Building C B 15.9 105.3 91 BOX 42 15-May-07 403.0 Retaining Wall B 14.6 104.2 90 BOX 43 15-May-07 404.0 Retaining Wall B 16.1 105.4 91 BOX 44 15-May-07 404.5 Building B A 17.9 104.0 92 45 15-May-07 404.0 Building B/C A 17.4 105.5 93 46 15-May-07 405.0 Building C A 18.1 103.8 92 47 16-May-07 404.5 Retaining Wall A 18.9 101.4 90 48 16-May-07 404.5 Building F A 15.7 104.2 92 49 16-May-07 404.5 Building F A 16.3 102.6 91 50 16-May-07 406.0 Building G A 14.9 105.3 93 51 -1 6-May-07 407.0 Building F A 15.1 106.0 94 52 16-May-07 406.0 Building F A 18.2 101.7 90 53 17-May-07 407.0 Building G A 16.7 104.1 92 54 -1 7-May-07 407.5 Building F A 14.9 103.9 92 55 17-May-07 407.0 Retaining Wall A 17.9 98.1 87 Fail: 90% Required 56 17-May-07 407.0 Retaining Wall A 17.1 102.5 91 Retest #55 57 17-May-07 405.5 Building C A 15.9 102.9 91 58 18-May-07 405.5 Building B A 16.7 102.9 91 59 18-May-07 404.5 Building C B 15.7 105.9 92 60 .21 -May-07 406.0 Building B A 14.9 104.5 92 61 21-May-07 406.5 Building C A 16.6 105.1 93 62 21-May-07 409.0 Retaining Wall B 17.1 105.0 91 BOX 63 21-May-07 410.5 Retaining Wall B 18.5 103.8 90 BOX 64 21-May-07 411.0 Retaining Wall B 16.7 105.6 91 BOX 65 21-May-07 405.5 Building B A 16.4 105.4 93 66 21-May-07 406.5 Building C A 15.9 104.1 92 73 22-May-07 406.0 Site Fill B 17.7 103.9 90 74 22-May-07 406.0 Building A B 17.2 106.1 92 80 22-May-07 407.5 Site Fill B 15.7 105.7 92 81 22-May-07 407.5 Building A B 14.1 105.5 91 82 22-May-07 406.5 Building A B 16.9 104.3 90 95 23-May-07 404.5 Building H A 16.6 104.4 92 BOX 96 23-May-07 404.5 Building H A 17.9 103.1 91 BOX 97 23-May-07 403.5 Building I A 15.1 105.5 93 BOX 98 23-May-07 405.5 Building I A 17.5 103.0 91 BOX 99 23-May-07 403.0 Building I A 16.6 104.3 92 BOX 100 23-May-07 408.0 Site Fill B 17.4 101 23-May-07 408.0 Building A A 07M132-1 Bressi Ranch Lots 33-39 -- Carlsbad, California Page 2 -M M T I SUMMARY OF FIELD DENSITY TESTS Test No. Date Elev. Test Soil Moisture Dry Density Relative Comments (ft) Location Type Content (Pct) Compaction (%) (%) 102 23-May-07 407.0 Building A B 16.6 107.6 93 105 24-May-07 405.0 Retaining Wall B 13.9 105.2 91 BOX 106 24-May-07 408.0 Retaining Wall B 13.7 106.3 92 BOX 107 24-May-07 405.0 Building I A 17.8 105.6 93 108 24-May-07 405.0 Building I A 18.1 102.5 91 111 25-May-07 407.0 Retaining Wall A 15.1 101.9 90 12 25-May-07 411.0 Retaining Wall B 16.2 105.9 92 113 25-May-07 407.0 Building I E 14.7 110.0 92 114 25-May-07 406.5 Building H E 15.1 108.8 91 115 25-May-07 407.0 Building I E 15.9 110.4 92 116 25-May-07 406.5 Building H E 15.6 110.5 92 117 29-May-07 409.5 Retaining Wall E 15.9 110.2 92 118 29-May-07 410.5 Retaining Wall E 14.7 113.1 94 119 29-May-07 412.5 Retaining Wall E 14.5 111.2 93 120 29-May-07 412.5 Retaining Wall E 15.8 110.5 92 121 29-May-07 409.0 Building I A 18.8 102.3 91 122 29-May-07 408.0 Building I A 16.4 105.0 93 123 29-May-07 407.5 Building H A 16.9 103.8 92 124 29-May-07 407.0 Building H A 17.5 _103.5 92 129 30-May-07 406.5 Building D A 19.7 103.0 91 BOX 130 30-May-07 405.5 Building DIE A 14.1 102.1 90 BOX 131 30-May-07 406.5 Building E A 16.9 103.2 91 BOX 132 30-May-07 407.5 Building E E 14.6 110.3 92 133 30-May-07 407.0 Building D E 15.7 109.2 91 134 30-May-07 407.0 Building D E 13.1 109.5 91 135 30-May-07 408.5 Building E E 13.1 111.7 93 136 30-May-07 407.0 Building D E 16.6 108.3 90 137 31-May-07 408.0 Building B A 14.9 103.3 91 138 31-May-07 407.0 Building B/C A 14.1 102.7 91 139 31-May-07 407.0 Building C E 16.7 110.7 92 140 31-May-07 407.5 Building D E 17.1 108.1 90 141 31-May-07 410.0 Building E A 15.1 102.5 91 142 01-Jun-07 409.0 Building B A 17.6 102.3 91 143 01-Jun-07 409.0 Building C E 14.6 108.6 91 144 01-Jun-07 409.0 Building D E 14.4 109.8 92 145 01-Jun-07 410.5 Building E E 15.6 107.5 90 155 04-Jun-07 408.0 Retaining Wall B 16.6 103.8 90 156 04-Jun-07 410.0 Retaining Wall B 15.9 _104.6 91 157 04-Jun-07 411.5 Retaining Wall B 16.3 105.2 91 07M132-1 Bressi Ranch Lots 33-39-- Carlsbad, California Page 3 -M M T I SUMMARY OF FIELD DENSITY TESTS Test No. Date Elev. Test Soil Moisture Dry Density Relative Comments (ft) Location Type Content (pcf) Compaction (%) (%) 158 06-Jun-07 409.0 Building A G 14.8 106.4 90 159 06-Jun-07 408.5 Building A G 14.5 107.9 91 160 06-Jun-07 409.5 Building B H 15.0 104.5 90 161 06-Jun-07 410.0 Building C H 14.3 105.7 91 162 06-Jun-07 410.0 Building D H 13.9 105.3 91 163 06-Jun-07 411.0 Building E H 13.5 106.9 92 164 06-Jun-07 408.5 Building H H 14.1 105.1 91 165 06-Jun-07 409.0 Building I H 14.6 104.2 90 178 07-Jun-07 410.0 Building A H 14.1 103.9 90 179 07-Jun-07 411.0 Building NB H 15.3 104.8 90 180 07-Jun-07 411.0 Building B H 11.6 103.2 89 Fail: 90% Required 181 07-Jun-07 412.0 Building C H 13.5 106.1 91 182 07-Jun-07 412.0 Building C/D H 14.8 105.7 91 183 07-Jun-07 412.0 Building D H 15.1 104.5 90 184 07-Jun-07 412.5 Building E _H_ 14.2 105.2 91 185 07-Jun-07 411.0 Building B _H_ 14.5 105.5 91 192 11-Jun-07 408.5 Building H _H_ 14.9 101.9 88 Fail: 90% Required 193 11-Jun-07 409.0 Building H _H_ 14.2 104.1 90 194 11-Jun-07 410.0 Building I i-i 13.8 104.7 90 195 11-Jun-07 410.0 Building I H 13.5 105.3 91 196 11-Jun-07 408.5 Building H H 14.0 105.8 91 Retest #192 197 11-Jun-07 410.5 Building H H 14.5 106.3 92 198 11-Jun-07 411.0 Building H/I H 13.8 105.9 91 199 11-Jun-07 411.5 Building I H 11.3 102.6 88 Fail: 90% Required 200 11-Jun-07 411.5 Building I H 14.1 105.4 91 201 11-Jun-07 411.5 Building I H 13.6 104.9 90 Retest #199 208 12-Jun-07 410.0 Site Fill G 14.8 107.4 91 209 12-Jun-07 410.0 Site Fill G 15.4 106.6 90 210 12-Jun-07 410.0 Building A G 15.1 107.9 91 217 13-Jun-07 410.5 Retaining Wall G 13.9 108.8 92 218 13-Jun-07 411.5 Retaining Wall G 14.5 107.1 91 219 13-Jun-07 413.5 Retaining Wall H 14.1 106.4 92 220 13-Jun-07 413.5 Retaining Wall H 13.5 106.8 92 221 14-Jun-07 408.0 Site Fill H 14.8 105.3 91 222 14-Jun-07 409.0 Site Fill H 13.9 103.1 89 Fail: 90% Required 223 14-Jun-07 410.5 Site Fill H 14.3 106.5 92 224 14-Jun-07 411.0 Site Fill H 13.7 105.8 91 225 14-Jun-07 412.0 Site Fill H 14.5 104.5 90 226 14-Jun-07 412.5 Site Fill H 14.0 105.7 91 07M132-1 Bressi Ranch Lots 33-39 -- Carlsbad, California Page 4 - - - - - - - M _T I - - - - - - - - - SUMMARY OF FIELD DENSITY TESTS Test No. Date Elev. Test Soil Moisture Dry Density Relative Comments (ft) Location Type Content (pcf) Compaction (%) (%) 227 14-Jun-07 409.0 Site Fill H 15.1 106.2 92 Retest #222 228 15-Jun-07 FP Building E A 16.9 103.8 92 229 15-Jun-07 FP Building E A 17.4 104.4 92 230 15-Jun-07 FP Building D H 13.8 107.6 93 231 15-Jun-07 FP Building D H 14.4 106.9 92 232 15-Jun-07 FP Building C H 14.9 106.4 92 233 15-Jun-07 FP Building C H 15.5 105.2 91 234 15-Jun-07 FP Building B G 14.6 108.3 92 235 15-Jun-07 FP Building B H 15.0 105.9 91 236 15-Jun-07 FP Building A H 14.2 104.8 90 237 15-Jun-07 FP Building A H 13.9 105.0 91 248 18-Jun-07 410.5 Building H H 15.2 106.2 92 249 18-Jun-07 411.0 Building I H 15.8 105.5 91 250 19-Jun-07 FP Building I H 13.9 106.4 92 251 19-Jun-07 FP Building I H 14.3 105.8 91 252 19-Jun-07 FP Building H H 14.8 106.0 91 253 19-Jun-07 FP Building H H 12.9 101.6 88 Fail: 90% Required 254 19-Jun-07 FP Building H H 14.6 104.3 90 Retest #253 255 19-Jun-07 FP Building F H 15.3 104.9 90 256 19-Jun-07 FP Building F H 14.2 106.5 92 257 19-Jun-07 FP Building G H 14.9 105.6 91 258 19-Jun-07 FP Building G H 15.5 104.7 90 NOTES: BOX = Bottom of Overexcavation FP = Finished Pad Elevation Retests Performed After Recompaction All Tests Performed By Nuclear Test Method (ASTM D-2922) Elevations Referenced To Grade Stakes Set In Field By Others 07M132-1 Bressi Ranch Lots 33-39 -- Carlsbad, California Page 5 2 NSITY RELATIONSHIPS Soil Type Soil Description Maximum Dry Optimum Density (pcf) Moisture (%) A Orange Brown fine Sandy Silt 113.0 15.5 B Light Gray fine Sandy Silt 115.5 14.5 C Crushed Aggregate Base 133.0 6.5 D 3/4-inch Asphalt 146.0 N/A E Orange Brown fine. Sandy Silt with fine to coarse Gravel 120.0 13.5 F Dark Brown silty fine Sand (IMPORT) 124.5 10.0 G Light Gray fine Sandy Silt, trace medium to coarse Sand (IMPORT) 118.0 12.5 H Yellow Brown fine Sand, trace Silt (IMPORT) 116.0 12.5 3/4-inch Asphalt 146.0 N/A Note: All Moisture-Density Relationships determined per ASTM D-1 557 (Modified Proctor) 07M132-1 Bressi Ranch Lots 33-39 -- Carlsbad, California Page 1