Loading...
HomeMy WebLinkAboutCT 05-15; LA COSTA OAKS NEIGHBORHOOD 3.1, 3.3-3.5; INSPECTION REPORT; 2010-10-25City: CARLSBAD . * H&H PCS, Inc. ( ' USTON. . . .t 21831 Batton Rd. -- - Street: Grand Terrace, CA 92313 - - . Tel: 909-422-8990 Fax: 909-422-0841 Email: infohoustonandharris.com - InspectionReport I Inspection: 1, Date: Job #: Weather: Operator: Section #: Project Name: 10/25/2010 CT 05-15 drizzle Angel I LA COSTA OAKS NORTH Start Station #:0 End Station #: . Sheet#: . Drawing #: Cleaned: Line lD/INSP#: 20+90.23 23+58.38 446-5C yes Street: SITIO CALIENTE . Stat Map Pg.: 5. - . From MH: B-I INLET City: CARLSBAD - End Map Pg.,:, 5 To MH: B-5 C.O. Inp. method: VCR #: * - Section length: 275.08 ft Media #: - . Joint length: Reason of inspection : new inspection Pipe shape: . round . Section type: storm water - ,. . Pipe size: 18 inch . . . Area: - . .. . . - . Pipe material :. RCP Lining: Remarks: 4 5. 1:675 Position Observation - - 5- 8.05 - Begin Inspection At Upstream Manhole . . -. . p . 4 ! : 275.08 - End Inspection At Downstream Manhole - (ASS STflPMflAIPJ incin it Cia, CAPI flM H&H PCS, Inc. 21831 Batton Rd. - Street: Grand Terrace, CA 92313 Tel: 909422-8990 Fax: 909-422-0841 Email: info(&houstonandhams.com InspectionReport I Inspection: I Date: I Job #: Weather: Operator: Section #: I Project Name: 10/25/2010 I CT 05-15 drizzle Angel -2 LA COSTA OAKS NORTH Start Station #: I End Station #: Sheet #: Drawing #: Cleaned: Line ID / INSP #: 23+58.38 25+58.79 446-SC yes Street: SITIO CALIENTE Start Map Pg.: 5 From MH: 6-5 C.O. City: CARLSBAD End Map Pg.: 5 . . To MH: B-S C.O. Insp. method: VCR #: . Section length: 201.67 ft Media #: Joint length: Reason of inspection: new Inspection Pipe shape: round Section type: - storm water Pipe size: 24 Inch Area: Pipe material: RCP Lining: Remarks: 1:495 Position Observation - 5C.0 . . .- - 0.00 Begin Inspection At Upstream Manhole . -. End Inspection At Downstream Manhole CASS STORMDRAIPJ 10-2510 II Pane: 2 • ('$,• (API qFkAn H&H PCS, Inc. 21831 Barton Rd. - Street Grand Terrace, CA 92313 Tel: 909422-8990 Fax: 909422-0841 Email: info(houstonandhanis.com InspectionReport I Inspection: I Date: Job #: Weather: Operator: Section #: Project Name: 1012512010 CT 05-15 drizzle Angel 3 LA COSTA OAKS NORTH Start Station #: End Station #: Sheet #: ' Drawing #: Cleaned: Line IDI INSP #: 25+58.79 27+88.36 448-5C yes Street: SITIO CALIENTE Start Map Pg.: 5 From MH: B-S C.O. City: CARLSBAD End Map Pg.: 5 To MH: EXT B-2 INLET Insp. method: VCR #: . Section length: 238.03 it Media #: Joint length: Reason of inspection: new inspection Pipe shape: round Section type: storm water Pipe size: 24 Inch Area: ' Pipe material: RCP Lining: Remarks: 1:585 Position Observation 0.00 Begin Inspection At Upstream Manhole End Inspection At Downstream Manhole INLET CASS STORMORAIN 1O.2-lfl II Pane: -