Loading...
HomeMy WebLinkAboutCT 08-06; HIGHLAND JAMES SUBDIVISION; HYDROLOGY AND HYDRAULIC DRAINAGE REPORT ADDENDUM; 2018-04-02.. ., HYDROLOGY/ HYDRAULIC DRAINAGE REPORT ADDENDUM 100-YEAR PEAK FLOW IN POST-DEVELOPMENT CONDITIONS For HIGHLAND JAMES SUBDIVISION APN: 207-130-75-00 to 207-130-78-00 Prepared for: Client: Elizabeth Temple Prepared by: R·E·C Consultants, Inc. Raab Rydeen REC Consultants, Inc. 2442 Second Avenue Sa n Diego, CA 92101 ' Telephone: 619-232-9200 ECEIVED APR 3 0 2018 LAND DEVELOPMENT ENGINEERING Report Prepared: April 2, 2018 RECORD COP -~-1-vi\\OJ lnitI,1I Date Section 1 -EXECUTIVE SUMMARY 1 -Introduction & Objective This document will serve as a storm drain design addendum for the connection and conveyance of onsite runoff (from the approved Highland James Subdivision) to the existing offsite public storm drain system on James Drive. The objective of this addendum is to verify size, capacity and construction of two 1 O" PVC storm drain pipes in parallel. The Highland James Subdivision is currently under construction. It has been discovered that a group of underground electrical conduits run along the frontage of Lot 3 within the right-of-way of James Drive. These existing electrical conduits prohibit the installation and connection of the proposed 18" PVC storm drain conveyance pipe that will convey the onsite runoff to an adjacent existing public storm drain inlet. Because of this, an alternative connection is proposed using two 1 O" PVC storm drain pipes in parallel as a replacement for the 18" PVC storm drain pipe. The parallel pipe system will be constructed between the existing electrical conduits and convey onsite runoff to the public storm drain system. Post-developed runoff data from approved Hydrologic/Hydraulic Drainage Report for the 100-year peak flow (prepared by Terramar Engineering) shall be used in this study to verify size and capacity of the dual 1 O" parallel pipe system. 2 -Methodology The maximum capacity flowrate (cfs) for the two 1 O" PVC storm drain pipes in parallel has been determined using the Hydraflow Express Extension for Autodesk AutoCAD Civil 3D (an AutoDesk 2015 product). This program utilizes the Manning formula to calculate the channel characteristics for particular flow instances. The Manning formula estimates the flow rate of a liquid flowing in a conduit that does not completely enclose the liquid , i.e. open channel flow. 2 3 -Calculations Post-Development Site Flow Rate per approved Hydrologic/Hydraulic Drainage Report: 2.99 CFS Two 1 0" PVC Pipes in Parallel Dimensions: 0.83' = Diameter (interior length) 0.83% = Slope (0 .08'/9.60') 0.009 = "n" Value" (Manning's Roughness Coefficient for concrete) Manning's Equation: Q =VA= ( 1 ·: 9 )AR i -Js Q = Flow Rate (cfs) n= Manning's Roughness Coefficient A= Area (sf) = 0.55 sf R = Hydraulic Radius (ft) = 0.42 ft S = Slope (ft/ft) = 0.0083 Findings / Results: Dual 1 0" Pipes in Parallel Flow Rate = 4.64 cfs Post-Development Site Flow Rate= 2.99 cfs It is determined that the dual 1 0" PVC storm drain pipes in parallel flow rate capacity is larger than the Post-Development Site Flow Rate for a 100-year peak storm. Please refer to attached Highland James Subdivision Hydraflow Channel Report and Exhibit for construction details. 3 Channel Report Hydraflow Express Extension for Autodesk® AutoCAD® Civil 30® by Autodesk, Inc. Highland James Subdivision Circular Diameter (ft) Invert Elev (ft) Slope(%) N-Value Calculations Compute by: Known Q ( cfs) Elev (ft) 129.00 127.50 127.00 0 = 0.83 = 127.58 = 0.83 = 0.009 Known Q = 2.32 Wednesday, Apr 18 2018 Highlighted Depth (ft) = 0.57 Q (cfs) = 2.320 Area (sqft) = 0.40 Velocity (ft/s) = 5.85 Wetted Perim (ft) = 1.62 Crit Depth, Ye (ft) = 0.68 Top Width (ft) = 0.77 EGL (ft) = 1.10 Section 2 Reach (ft) "' ~ " ·a ., 0 ~ :, 0 -e 8 -"' 0 ~ " -0 i7i / 00 oi N .-j ·a ., □ ~ ::, 0 .0 5 u -" 0 ;, <!) 31 i 15 a. "' ~ >, 0, 0 0 ! ;;- c 0 ·;;; ~~ ] ::, <11 a; "' § ..., "t, § }· 0 '° N ;;-- " C () <( / a: ~ ~ d 00 0 N .....__ ..... N .....__ ..,. I 00 0 N .....__ 00 --::.. ..,. EXISTING TRANSFORMER TO REMAIN. PROTECT IN PLACE I PROJECT SITE LOT 3 INLET . PER SDRS D-29 I 2 ~10" RCP SD 0 (/) a 0 (/) a 0 (/) a 0 (/) a (/) a V) '° <1 1 0 (/) 00 -st- PROPOSED GRADE PER DWG. 483-6B I re_ I EXISTING CURB INLET TO REMAIN (130.4) TG (127.5) IE l~tl-4" ss __ , 4" ss ----4" ss _j --4" INLET PER SDRSD D-29 131.68 TG 127.58 IE ] EXISTING GRADE I (bl I . ~9.10' \ \ I \ I \ V) -"9-- i~ ~ \ ( EXISTING CONDUIT CROSSING TO REMAIN. PROTECT V). IN PLACE V) I 1 1 . '° I (bl I V) \7 V) I '° . I /JJ·I .I V) <1 I I I I V) '° '7 0 (/) co v 1" 1,/ --1" 1,/ _L 1' I -- EXISTING INLET TO REMAIN (130.4) TG (127.5) IE 0 (/) 00 -st- m m 127.58 FL OUT PROPOSED TWO 1 O" STORM DRAIN PIPES IN PARALLEL SEE DETAIL BELOW FOR DIMENSIONS _ _J CONTRACTOR TO CONNEC T PIPES TO EXISTING CURB INLET (127.5) FL IN -18" SD ·1{' PROFILE VIEW-NEW PVT CATCH BASIN TO EX. PU BLIC CURB INLET CONNECTION SCALE: 1" = 5' Sl SD MH TO REMAIN ~ ~ ~ Q Cl) ~ ~ 00 v 0 ~0 co v (130.9) TG (1 26.5) IE (1 8"). (125.4) IE (48") INLET PER SDRSD, ~ D-29 AND 2~10" SD RCP PER DWG. 483-6B vi 'ic v 0 (/) 00 'SI- 127.58 FL OUT ~.......,.......----,--r--77 r---- ,- ci J_ r------.;j- 0 I") co c:i EXISTING CURB INLET TO REMAIN (127.5) FL IN PLAN VIEW -Ncf,,,J ?VT1 C.ATC-U ·SP.SIN 7c, CltC. CAUTION: EXISTING ELECTRICAL CONDUIT TO REMAIN . PROTECT IN PLACE. ~-9.6' SCALE: 1" = 5' 0 C: X ~ a> 0 E <'i C: C1> 0) O c: I .~ •-N > >-..., C: a> N w c: s • ::::s ., ~ ~ g>cn ~~e •-cuN ..... -0 > c,, ~c:<<(8 c:0 -o(.)N •-....I C a, g> 80~ w ., g,..., (I) -N == "'oa, .2: ~ 5 <D <..) N (/) ..__, (.) C Cl) ...., C 0 ...., ::::s Cl) C , ■8 CX) •• .,... 0 ~ .. in .. w wo ~0 ~0 Gr:i I-I<( <C --;;W-ci <(.,-U a 0::: .::i: • o o (/)..-o a:: u m ....J <( I- UJ 0 C") I-I- UJ 0 _j ....J I- ::J z 0 0 (lJ Cl) w co 0::: ->o ::J >-o -0::: N () 0 0 0) ~ Cl) 0 <!.- ::J zu ....J <( - <( Cl) ....J 0 s Cl) a ;:a UJ w -....J I UJ 0 2 0 0::: -<( g=; <!. Cl) 7 ('°) u 0 0 UJ z LL <( 0 _J 0 :r: 2 C) .,:r: w i=! I~ i== u I-w w -:, w 0 ::i: a::: V) Q. Pu&IC. 6 U R.B IN<.-Gi C-e>i,VNGCTlt';J DIMENSION DETAIL 0 •. SCALE:NTS SHEET 1 OF 1 SHEETS i ---- I ,; 4 -Declaration of Responsible Charge I HEREBY DECLARE THAT I AM THE ENGINEER OF WORK FOR THIS PROJECT, THAT I HAVE EXERCISED RESPONSIBLE CHARGE OVER THE DESIGN OF THE PROJECT AS DEFINED IN SECTION 6703 OF THE BUSINESS AND PROFESSIONS CODE, AND THAT THE DESIGN IS CONSISTENT WITH CURRENT STANDARDS. I UNDERSTAND THAT THE CHECK OF PROJECT DRAWINGS AND SPECIFICATIONS BY THE CITY OF CARLSBAD IS CONFINED TO A REVIEW ONLY AND DOES NOT RELIEVE ME, AS ENGINEER OF WORK, OF MY RESPONSIBILITIES FOR PROJECT DESIGN. 4