HomeMy WebLinkAboutCT 72-03; TRI-CITY AUTO PLAZA; RESULTS OF FIELD DENSITY TESTS; 1973-04-24• BENTON ENGINEERING. iNC. ~~:; FI'c--c APPLIED SOIL MECHANICS -FOUNDATIONS c! T72--3 6717 CONVOY COURT SAN DIEGO, 'CALIFORNIA 92111 PHILIP HENKING BENTON PRESIDENT· CIVIL ENGIHEER April 24, 1973 TELEPHONE (714) 565.1955 Mr. Howard Hasse tt c/o Bridge Iviotor Inn 1103 North Hill Street Oceanside, California 92054 C'12-«>'3 RECEIVED Subiect: Gentl~men: Pro fect No. 72'-10-30' Results of Field Density Tests Taken in Subgrade and Base Materials Tri-City Auto plaza Carlsbad, California APR 2 5 1~13. ClTY Of CARLSBAD Engineerlng Department This is to report the results of field density tests taken in compacted subgrade and base materials at the subject site during the period between April 2 and April. 18, 1973. The tests were taken on the dates indicated below: Test Number 1 to 10, inclusive 11 to 13, inclusive 14to 19, inclosive' 20 to 27, inclusive 28 to 33, inclusive 34 to 37, inclusive Date Aprii 2, 1973 April 4, 1973 April 6, 1973 . April 10, 1973 April 13, 1973 April 18, 1973 The approximate locations at which the tests ~re tdkenand the final test results are presented On pages 2 to 5 , inclusive, under the IITable of Test Results.1I The laboratory determinations of the maximum dry densities and optimum moisture contents of the materials are presented on . page 5, under' the II Laboratory Test Resul ts. II Respectfully submitted, BENTON ENGINEERING, INC. By-d?C~ . R. C. emer Reviewed ~, f{(~ I Piij)H.Benton,Civii Engineer. I Distr: (5) Addressee (2) City of Carlsbad Engineering Department (1) Fiest , Vetter, Knauf & Loy Attention: Mr. R. KnalJf RCIVPHB/meg r; ilt),... ..... . "l Project No. 72-10-3D e -2-e Apri I 24, 1973 . Tri-<:ity Auto Plaza TABLE OF TEST RESULTS Depth of Maximum Test Below Field Dry Dry Test . Approximate Existing Sur-Moisture Density Density Percent No. Location face in Feet % dry wt Ib/cuft Ib/cu ft Compaction 1 Subgrade Over 0.3 8.0 120.5 129.4 93,1 Sewer Lateral, Sta. 1 + 43 251 East Of West Curb 2 Subgrade Over 0.2 7.2 122.8 129.4 94 .• 8 Water Lateral, Sta. 4 + 90 201 East of West Curb 3. Subgrade Over 0.2 6.5 122.2 129..4 94.5 Storm Drain, Sta. 8 + 65 91 East of West Curb 4 Subgrade, 0 .• 2 7.9 127.3 132.6 96.1 Sta. 24 +50 151 East of West Curb 5 Subgrade Over 0.3 8.7 129 .. 7 132 .• 6 . 97.8 Sewer Main, Sta. 19 + 50 6 Subgrade Bet~en 0.2 8.0 123.4 . 129.4 95.5 Sewer And Water Laterals; Sta. 17 + 55 7 Subgrade, 0.2 8.4 125.9 129.4 97.2 Sta. 16 + 20 101 East of West Curb 8 Subgrade, 0.2 7.4 123.4 129.4 95.5 Sta. 11 + 50 121 East of West Curb 9 Subgrade, 0.2 . 8.5 123.8 129.4 95.7. Sta. 0 + 90 On Private Street . Between Lots 7 & 8 BENTON ENGINEERING, INC. .... , ... ~ .' I"·' I 'project No. 72-10-30 • -3-• April 24, 1973 f~-·' <Trt-City Auto Plaza TABLE OF TEST RESULTS (CONT.) Depth of Maximum Test Below Field Dry Dry Test Approximate Existing Sur-Moistur~ Density Density Percent No. Location face in Feet % dry wt Ib/cu ft Ib/cu ft Compaction ' 10 Subgrade, 0.2 7.7 123.4 129.4 95.5 Sta. 3 + 55 on Private Street Between Lots 7 & 8 11 Subgrade, 0* 7.6 124.3 128.6 96.7 Sta. 7 + 70 West Side 12 Subgrade, 0* 8.3 .125.3 129.4 96.8 Sta. 16 + 20 West Side lS Subgrade, 0* 8.0 127.7 128.6 99.3 Sta.27+50 West Side 14 Base, 0* 7.7 133.0 127.5 1-04.2 Sta. 30 + 00 West Side 15 Base, 0* 5.,4 131.5 127.5 103.0, Sta. 25 + 00 West Side 16 Base, 0* 7.3 129.8 127.5 101.7 Sta. 20 t 00 West Side 17 Base, 0* 5.3 125.8 r27.5 98.6 Sta. 15 + 00 West Side 18 Base, 0* 5.0 126.0 127.5 98.8 Sta. 10 + 00 West Side 19 Base, 0* 5.6 124.8 127.5 97.8 Sta. 5 + 00 West Side 20 Base, 0* 4.8 1,26.1 127.5 98.9 Sta.28+00 East Side * -Indicates Test Was Taken In Upper 6 Inches Of Existing Subgrade Or. Base Course BENTON ENGINEERING. INC. '; Protect No. 72 .... 10-3D • -4-• AprU 24, 1973 ~.:...~.' ~ Tri-City Auto Plaza TABLE OF TE~T RESULTS (CONT.) Depth of Maximum 'Test Below Field Dry Dry Test Approx'imate Existing Sur-Iv\oisture Density Density Percent No. Location, face in Feet % dry wt Ib/cu ft Ib/cu ft CompClction 21 Base, 0* 6.0 131.8 127.5 103.2 Sta. 23 + 00 East Side '22 Base, 0* 5.0 131.6 127.5 103.1 Std. 18 + 00 East Side 23 Base, 0* 6.7 127.2 127.5 .. 99.9 ''';f' Sta. 13 + 00 ," East Side I .,~.~"~4 ' Base, 0* 4.8 127.1 127.5 99.7 ~/~;'.'~~;' Sta. 8 + 00 ' .. { .l· .~ East SIde "::-"Q,5, ." '. Bas~, 0* 6.0 124.5 127.5 97.7 Sta. '3 + 00 East SIde 26 Base, ' <r~ 5.3 126.9 127.5 99,.5 Sta. 1 + 50 On Private Street . Ecst Of Plaza Del Norte, Sta. 19 + 39 '27 Base, 0* 5.0 124.8 127.5 97,.9 Sta. 4 + 00 On ' Private Street East of Plaza Del Norte, ;. .... Sta. 19 + 39 ~8 Subgrade, 0* ,7.2 124.:0 127.2 97~3 Sta. ?3 + 00 5.0 117.0 125.5 93.2 29 Subgrade" 0* " Sla. 38 + 00 ' , ' :' 30 Subgrade, ·0* 5 .• 4 11-7.9 125~5 93.9' : ":.' . Sta. 43 + 00 ,31 Subgrade, ' 0* 10.2 119.2 128.6 92·.7 Sta. 48 + 00 32 Subgrade, 0* 6.1 121.1 128 .. 6 94.3 ' Sta. 53 + 00 , * -Indicates Test Was Taken In Upper 6 Inches 9f Existing Subgracle or Base Course BENTON ENGINEERING. INC. .. ;c.~{£ . /ro lect No. 72-10-3D ! -5-• Apri I 24, 1973 • " > Tri-City ~uto Plaza TABLE OF TEST RESULTS (CONT.) ~ Depth of Maximum Test Below Field Dry Dry Test App roxi mate Existing Sur-Moisture Density . Density P~rcent No. Location fac~ in ·Feet % dry wt Ib/cu ft Ib/cu ft Compaction 33 Subgrade, 0* 5.0 127.0 ' 129'.4 98.2 Sta.58+00 34 ' Base, 0* 5.7 127.9 127.5 100.2 Sta. 37 +00 35 Base, 0* i.l 126.9 127.5 99.4 Sta. ,43 +00 36 Base, 0* 6.8 124.8 127.5 97.8 Sta. 49 + 00 37 Base, 0* 6.8 131.0 127.5 102.8 Sta. 55 + 00 * ... Indicates Test Was Taken In Upper 6 Inches of Existing Subgrade or Base Course . LJ\BORATORY TEST RESULTS The ma~imum dry densities and optimum moisture contents of the maior fill materials as deter- mined by the A.S. T .M. D 1557-66Tmethod, that uses 25 b.lows of a 10 pound rammer falling from a height of 18 inches on each of 5 fayers in a 4 inch diamete'r 1)30, cubic foot ~tnp'action cyBnder, c;Jre presented os follows: ' ., -, $a-i1 Description Dark brown silty fine to mediul\I sand Red-brown clayey fine to medium sand Brown silty fine to medium sand Brown silty fine to medium sand Brown slightly silty fine to medium sand Brown slightly silty fine to medium sand . (D. G. Bose) BENTON ENGINEERING, INC. Ivlaximum Dry Density Ib/cu ft 1.29.4 127.2 ,125.5 132.6 128.6 127.5 Optimum Moh- ture Content % dry wt 8.4 10.8 9.2 7.8 8.8 8.5