Loading...
HomeMy WebLinkAboutCT 72-20; 3171 Venado Street Condominium Complex Unit 2; Soils Report Addendum to Third Interim; 1986-11-04CATLIN ENGINEERING, INC. P.O.Box4225 La Mesa, California92044-0970 (619) - (619) 588.85OQ - - - - Continental American Properties 1764 San Diego Avenue San Diego, CA 92110 ATTN: Mr. Vic Baker November 4, 1986 Subject: Project No. 2OC5C Addendum to Third Interim Report of Compacted Filled Ground Proposed Condominium Complex 3171 Venado Street Carlsbad, California Gentlemen: We refer to our First Interim Report of Compacted Filled Ground prepared for subject site dated March 12, 1986, Second Interim Report of Compacted Filled Ground dated October 9, 1986 and Third Interim Report of Compacted Filled Ground dated November 3, 1986, and to reports by Benton Engineering, Inc, Final Report of Compacted Filled Ground dated November 27, 1974 and Site Inspection and Recommendations for Construction dated July 22, 1981. This addendum records our observations and the results of tests performed in connection with our inspection of the compaction of filled ground placed on certain areas of the above subject property. This property is more particularly referred to as Assessors Parcel Nos. 223-190-05, -06, -07, and -08 in the City of Carlsbad, County of San Diego, State of California. The grading reported herein was accomplished on November 3, 1986. The elevations of fill at which the tests were taken and the final test results are presented on page T-15 under "Table of Test Results". The laboratory determinations of the maximum dry density and-the optimum moisture content of the fill soils are set forth on page L-l under "Laboratory Test Results". The approximate location of the filled ground and the field density tests are presented on Drawing No 6 revised November 4, 1986, entitled "Approximate Location of Compacted Filled Ground". The results of the tests and observations indicate that the soils placed on subject site under our inspection have been compacted to at least 90 percent of maximum dry density. We note for clarity that the building pad for lot 278 is complete. The remainder of our third interim report of compacted filled ground remains in force. Pages T-15, L-l, and Drawing No. 6 are parts of this report. Consulting Engineers and Geologists - PAGE 2 CONTINENTAL AMERICAN/VENADO STREET 2OC5C NOVEMBER 4, 1986 - The opportunity to be of service is sincerely appreciated. Respectfully submitted, CATLIN ENGINEERING, INC. Civil Engineer - Distr. (6) Addressee - - - - - - - --~ _- - .- - _- - - - - - PAGE T-15 CONTINENTAL AMERICAN/VENADO STREET 2oc5c NOVEMBER 3, 1986 REVISED: NOVEMBER 4, 1986 TABLE OF TEST RESULTS Field Density Tests were performed in accordance with the applicable provisions of the current ASTM Standard D1556 and the results are presented below. Test Location Test No. of Test Elevation SEE DRAWING R5 245 LOT 282 FG/243.0 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 II FG/244.0 LOT 283 S.G. II S.G. II S.G. LOT 278 227.0 LOT 279 -3.5 LOT 278 229.5 II 230.0 II 230.5 LOT 277 FGl235.0 LOT 277 231.0 II 235.0 II 235.0 II 238.0 II 238.0 LOT 278 FG/232.5 II FG/232.5 Field Moisture % Dry Wt. Dry Density lb/tuft Soil Type 12.7 122.9 J 8.3 120.7 J 11.7 121.7 B 7.9 127.1 B 7.0 122.0 B 11.9 123.3 J 14.3 118.2 G 15.5 112.0 F 15.0 110.0 L 17.4 109.9 L 18.9 104.2 A 18.6 106.9 L 18.1 113.7 A 16.2 112.3 A 15.1 114.7 G 17.9 118.4 G 11.0 131.7 J 18.0 118.1 G Compac- Test tion % Date Remarks 92.3 10-23-86 90.7 " 95.2 10-31-86 99.5 n 95.5 " 92.7 " 99.9 n 91.4 11-01-86 95.7 " 95.8 ' 91.6 ’ 93.0 I4 99.9 n 98.7 ” 96.9 ’ 97.8 ” 98.9 11-03-86 99.7 ” - - - - .- - - - - - - PAGE L-l CONTINENTAL AMERICAN/VENADO STREET 2OC5C NOVEMBER 4, 1986 LABORATORY TEST RESULTS The maximum dry density and optimum moisture contents of the soils as determined by the ASTM D1557-70 method, that uses 25 blows of a 10 pound rammer falling from a height of 18 inches on each of 5 layers in a 4 inch diameter l/30 cubic foot compaction cylinder, are presented as follows: Soil Type A B C D E F G waw/A Soil Description Gray Tan silty Clay Red Brown Very Fine to Coarse Clayey Sand Green With Red Streaks Silty Clay Medium Brown Silty Fine Sand With Clay Binder Tan Yellow silty Clay Light Brown-Orange clayey Fine to Coarse Sand Olive Brown Fine to Medium Clayey Sand Gray Silty Fine to Coarse Sand Gray Brown Silty Fine to Coarse Sand Brown Clayey Fine to Coarse Sand Brown Silty Fine to Coarse Sand (Import) Maximum Dry Dens lb/cu.ft 113.8 127.8 106.3 122.9 120.4 122.6 118.4 14.0 137.4 6.9 138.6 7.2 133.1 8.9 125.5 8.7 ity Optimum Moisture Content % Dry Wt. 16.4 9.5 15.4 12.0 13.0 12.7