HomeMy WebLinkAboutCT 72-21; Tanglewood; Soils Reports; 1973-04-24INSPECTION TESTING RESEARCH DEVELOPMENT 6280 Riverdale St. San Diego, California 92120 Phone 280-4321 SCT 312022 Report No. 8 Attention: Mr. Walt Wood SUBJECT: Tanglewood Subdivision, Carlsbad, California. Gentlemen: In accordance with the conversation between Mr. Walt Wood and the under- signed, we herewith submit the following comments.. The recommendations previously submitted by Southern California Testing Laboratory, Inc. re- garding the preparation of foundation soils and foundation reinforcement for structures constructed within the existing fault zone have been com- plied with in those building pads and foundations constructed within the model area. The recommendations were as follows: The natural soils exposed within 3 feet of finished grade have been removed and recompacted to 90 percent of maximum dry density. Fur- ther, all foundations which will encroach on an area 15 feet wide along the fault trace will be reinforced with two No. 4 bars placed 3 inches above the base of the foundation and two No. 4 bars placed 3 inches below finish floor. / SlOlO .2.15 SCT 312022 April 24, 1973 Page Two - It is our recoinmendation that the measures described above be incorporated in all building pads and/or foundations which encroach upon the above de- scribed 15 foot wide zone. This zone will be delineated in the field by ~ - our geologist during site grading. __ Please do not hesitate to contact the undersigned if you have any questions regarding the comments contained herein. - This opportunity to be of service is sincerely appreciated. - Respectfully submitted, SOUTHERN CALIFORNIA TESTING LAB., INC. - DES: jle cc: (3) Submitted ., President