HomeMy WebLinkAboutCT 74-21; CARLSBAD OAKS BUSINESS PARK; AS-GRADED GEOTECHNICAL REPORT ADDENDUM; 1988-07-21- r71-aV SAN DIEGO GEOTECHNICAL CONSULTANTS, INC. SOIL ENGINEERING & ENGINEERING GEOLOGY iR T JUL 2 51988 Bedford Properties 2011 Palomar Airport Road Carlsbad, California 92009 Attention: Ms. Mary Jane Jagodzinski r ' Job No. 05-1O79-OO2-O3-1O Log No.i8 -18*56 SUBJECT: AS-GRADED GEOTECHNICAL REPORT ADDENDUM Carlsbad Oaks Business Center, C.T. 74-21 Carlsbad, California Reference: "As-Graded Geotechnical Report, Final Report of Mass Grading, Carlsbad Oaks Business Center, Carlsbad Tract 74-21, Carlsbad, California", February 19, 1987, Job No. 05-1079-002-00-10 Ms. Jagodzinski: In accordance with the request of Mr. Walter Brown, of the City of Carlsbad, we are providing this addendum to the referenced As-Graded Geotechnical report. The city is requesting additional information or a clarification regarding expansion potential and bearing capacity of the rough graded pads. The site was rough graded to construct street subgrade, sheet graded pads, and adjacent slopes. The sheet graded commercial lots consist of bedrock cut areas, and compacted fill soil primarily derived from the bedrock cuts. The soils exposed at pad grades generally exhibit an expansion index (per UBC 29-2) of medium to high. Foundation recommendations were not included in our referenced as-graded report because specific building and foundation plans were not available, and the pads are usually fine graded later to suit the proposed buildings, parking, driveways, etc. The 6455 NANCY RIDGE DRIVE • SUITE 200 • SAN DIEGO, CALIFORNIA 92121 • (619) 587-0250 / Bedford Properties Job No. 05-1079-002-03-10 July 21, 1988 Log No. 8-1856 Page 2 anticipated bearing capacities will be typical for compacted fill soils and sedimentary bedrock. The capacities will vary depending on the foundation depth, type, and soils (i.e. fill or bedrock). A specific foundation investigation should be performed by the soils engineer for each proposed building. This investigation should include but not be limited to: foundation beáiicapacfties, fine grading recommendations, pavement sections, expansive soil mitigation recommendations, surface drainage recommendations, and cut/fill transition mitigation if applicable. The referenced as-graded report should be reviewed prior to site improvements being made, and for any geotechnical foundation investigation performed. This opportunity to be of service is sincerely appreciated. If you should have any further questions, please do not hesitate to contact the undersigned at your convenience. Very truly yours, SAN DIEGO GEOTECHNICAL CONSULTANTS, INC. 44UJ JAO)Jr Kenneth W. Shaw, C.E.G. 1251 Anthony Pr. Belfast, P.E. C 40333 Registration Expires: 6-30-90 Registration Expires: 3-31-91 Associate Geologist Chief Engineer KWS /AFB/pb Distribution: KENNETH SHAW No. 1251 * CERTIFIED ENGINEERING GEOLOGIST OF kv ff -, A4 V. (2) Addressee (2) City of Carlsbad Engineering 2075 Las Palmas Drive * Carlsbad, CA 92008 4 Attn: Mr. Walter Brown It.)