Loading...
HomeMy WebLinkAboutCT 79-05; LA COSTA GREENS; SUPPLEMENTAL RECOMMENDATIONS TO OUR LIMITED SOILS INVESTIGATION PROPOSED ALTA VERDE CONDOMINIUMS LOTS 6 AND 7; 1979-10-11·. • l ... ~ .. .• t-'• BENTON ENGINEERING, INC. APPLIED SOIL MECHANICS -l"OUNDA.TION8 111"·0 RU FPIN ROAD SAN DIEC.O, CALIFORNIA 1212:11 · October 11, 1979 PHILIP HENKINQ BENTON P'"lt810SltT • CIVIL. &NlilNl:1:11 Frederlck J. Meyer, A. I .A. Architect & Associates 2348 Harcourt Drive San Diego, ~allfornla 92123 Attenttonz Sub{ectz Gentlemen, Mr. Frederl ck M.e ye r Pro}ect No. 79-8-23A Supplemental Recommendations to our Ltmlted Soils Investigation, Proposed Alta Verde Condominiums, Lots 6 and 7 of Lo Costa Greens Subdivision, North of La Costa Avenue, °Carlsbad, ColJfornta dated October 2, 1_979 TSL.SP'HON& (714) HS-19811 This ts to supplement the subJect report with re.gard to the drainage recommendatl~na lncludaci on page 7 of our report dated October 2, 1979 that would apply for expcmslva so!I condltlona exbtfng u~dernoath the concrete slabs In the butldlng units. · This recommended drainage away from al I perimeter footings may be reduced to the 2 1/2 feot distances shown on your "Grading Plan for Alta Verde Condc,minlurm, Lots 6 and 7 of l.,.a Cosi'o Greens, ,Ylap 6708, Sheet 2 of 2 Sheets", provided 3 feet of non~xpamJve solls are placed an.d compacted .durfng grodlng immadlately benec;th the cd{acent concrete slabs of the buildings .. Thls· wtll probably require spe~lal handlrng of select non-eY.pan,tw, fflQterlals 01.U"ing rM grading for th?s development. Jt ls unknown at this time whether enough non-expansive sol!:. exist on th6 stl'e 10 provltja fur this 3 foot thickness of non-expansive flli ground beneath the buJldJng pad concrete ilabs. 1f tnsufflclent quantities exist to be used In the upper 3 feet of grade, then select non-expansive solls meeting the followlng criteria will have to be Imported to the site and placed ond · ~pgct,d In the upper 3 feet below thia pad grade. The Import should meet °the ~!IPWfng crlterlc:u (o) These shall be a silty sand, :slightly eiciyey ~and, or send soli type. (b) These shall have no more than 40 percent passing the No. 200 sieve sl:te. Abo, ct least 50 percent shall pass ti,., No. 4 sieve size and It shall contaln no gravel larger than 3 Inches. . . . .. • ... ~ .. _ ... _. •. '·"' e \ Frederick J. Meyer, A. I .A. Protect No. 79'.'"8-23A. . ~2-October 11, 1979 (c) The expansion of a one Inch htgh sample of the minus 10 mal'erlal remolded to 92 percent of maximum dry dens tty Qnd then air dried for two days at 105° F 1 then loaded to 500 pounds per square foot and saturated, shall not exceed 2.5 percent. Respectfully submitted, . BENTON ENGINEERING, INC. ~·~~ . By~nt~~ RCE No. 10332 PHB/Jr Dtstrlbutloni (2) Addressee (2) City of Carlsbad 1200 Elm Avenue Carlsbad, Cclffornla 92908 Attention: Nir. Bryan Mell !ch •INTQN l'iNQINIIUUNO, INC,