Loading...
HomeMy WebLinkAboutCT 82-14; TEMPLIN HEIGHTS; CLEARANCE REPORT ON SOIL CONDITIONS; 1984-03-19I . . . $7,13 1984 lIEERIN8 SOIL AND MATERIAL TESTING LABORATORY. . . c OF NORTH COUNTY. INC. . 19 march 1984 . . . 423 HALE AVE. - ESCONOIDO. CALIF. 9202S ESCdNOIDO - 746-2333 Mr. Ed Elliott . . . . McMillin Development Company - .2727 Hoover Avenue . . . National City, California 92050 . : . •. . Job No. 83-58 . . . .• S. •• T.emplin Heights, Unit 3 Carlsbad Tract No. 82-14 Carlsbad, California SUBJECT: Clearance Report on Soil Conditions(CO\PD L.41..YZE,'bALT) Dear Mr. Elliott: . . . . . This report is to present the results of our soil tests and observations done at your request for the. grading of the above-re— ferenced site .T.ho recommendations for grading preparation contained in our Preliminary Soil Investigation. Report dated 23 August 1976 were followed to our satisfaction All cut (native ground) lots were ripped approximately 1 foot, watered, and recompacted to not less than 90% of the maximum dry density. S • • S . .• . . . . In all lots in which day—lite line transects the house pad the cut portion was undercut approximately 1 foot then ripped approxi— mately 1 foot in depth., wate.red, andrecompacted. The undercut area was then refilled with nonexpansivesoils and compacted. at least 90% of the maximum dry density . . . The results of our observations, field density and laboratory tests indicate the compacted fill and recompacted ground has been placed at not less than 90% of the maximum dry density. (• The approximate areas undercut, the areas ripped, and the fill areas tested are shown on the enclosed site plan. Two expansion tests were performed on a undisturbed and a re— molded sample of the most abundant clayey soils encountered to de- termine if these materials would constitute a structural hazard to'•the buildings with respect. to volumetric soil change. The remolded test was performed on soil samples remolded to 90%' of the, maximum dry density at. optimum moisture content in 2 inch diameter, 1 inch high. ring molds to approximate the. compacted fill condition. The undisturbed test was . performed in an identical ring mold. All samples were loaded with 1 psi, instrumented, air dried and then submerged in distilled water until ,the expansion stopped.. The percent expansion is recorded aS the ratio of the final change in height to the initial height EXPANSION TESTS Location Depth. of Test Initial Air Dry Saturated Expansion Test Type w • w w Lot 215 -1-51 U 15.6 114 1 10.5 116.2 19.8 109.7 5.9 Lot 215' —1.0'' R '38.4' 82.1 28.6 84.4 50.6. 69.9 20.1' W = moisture content ?f= •dry density (pcf) U = undisturbed test R = remolded test The expansion tests indicate..the upper native soils on certain lots to be in the high to critical range and could constitute structural hazard' to the buildings. In order to minimize the possibility of struc- 'tural damage" to the buildings on Lots 210, 215 through 219 and 243 the following 'recommendations are, made. SOIL AND MATERIAL TESTING LABORATORY , OF NORTH COUNTY. INC. —2— ' We recommend that the foundations inc'uding the garage be post—t (ned. Exterior concrete slabs, such as driveways, sidewalks, patios, pool decking, etc., shall be founded 'on at least 4 inches thick of clean imported sand or clean nonexpansivé • on—site soils approved by our laboratory. C. It is recommended that moisture be re—established 1 foot below the footing and slab areas such that the optimum moisture is exceeded by 'at'least 3 percent within 48 hours prior to pouring.. This applies both to the garage and living areas. 0 It is believed no expansive soils' are found within the upper 3 feet on the remaining lots (207 through 209, 211 through 214, 220 through 242 and 244) of' the subdivision.' ' The below listed' foundation recommendations should be. followed. ' a. The'continuous. perimeter foundations shall extend a minimum depth -of 12" into the compacted fill or firm native ground for one story and at least 18" for' two story buildings. The continuous foundations will be reinforced with at least two No. 4 steel bars, one bar shall be placed near the top of the founda- tions and,the other bar, shall be placed near the bottom. A continuous 8" foundation is also recommended along the edge of the entrance. garage 'The concrete, floor slabs of the dwellings and' garages shall -be a minimum of 3k" in thickness and shall be founded on at least 3" thick of clean imported sands , or clean nonexpansive on—site soils approved by our laboratory. A plastic sheeting should be placed-be— tween the clean sand layers in the living areas. It is recommended that these concrete slabs in the living .areas and garages be reinforced with centered 6X6/1OXlO steel wire mesh. . As reported in our Preliminary Soil Investigation Report, an allowable, bearing capacity of 2400 psf may' be used for design purposes. Footings located closer than 5 feet. from the top of the slope should be extended until the bottom edge of the footing is at least 5 feet horizontally from ,the outside face of the slope. Direct and maintain drainage so that water does not pond around the foundation or top of slopes. Poor drainage around foundations SOIL AND MATERIAL 'TESTING LABORATORY' . OF NORTH COUNTY. INC. . —3— will contribute to 'the sitUation where existing clay soils could re— ceive increased moisture and clay heave could result Both laboratory-compaction and field density test procedures and results are presented on the following pages Our-firm -should inspect all footing trenches before reinforcing bars have been placed to verify the soils conditions are as reported herein and to verify the moisture conditions on the expansive soil lots .We understandall grading for Templin Heights,' Unit' 3 has been , completed However, if additional fill or backfill is to be placed, we should be. notified to insure that proper compaction is achieved. Respectfully submitted, SOIL 'AND mATERIAL TESTIJC " LABORA,JORY,, NORTH cyiiv, INC. - E. BRIAN SMITH, RCE 139 817 EBS bl Distribution (12) Addressee 'SOIL AND MATERIAL TESTING LABORATORY OF NORTH COUNTY. INC. —4— : 4 (• DENSITY DATA S 1 - Laboratory Compaction . Laboratory compaction tests were performed as specified by ASTM D1557-641 (method i). This test method uses the minus #4 sieve soil in a 4. inch diameter, 4 inch high cylindrical mold. The sample is formed with a 10' pound hammer falling. 18 inches for' 25 blows on each of 6 layers. .. . ' L A BORATORY COMPACTION TESTS Soil maximum Optimum Description ' Dry ' moisture Density . Content (pcf) 'Light Gray Silty.Sand with Clay trace. '. 117.0 ' ' 140 Brown Silty Fine Sand 125.0 9 8 Red—Brown Silty Sand 129.0 10.2 5. Red—Gray Silty Sand 'with Clay' trace , . , 123.6 • 10.5 Red Fine medium Sand . ' 1.20.5 , 1.0 Brown Fine Sand , •. ' . ' 103.0 ' .16.5 2 - Field 'Density Tests ' • • • • ' ' • • • • ' Field density tests were taken at selected locations during the grading to determine the moisture and density' conditions of 'the filled ground. These tests were performed according to ASTM 01556-64, the 'sand cone method. ' • ' ' ' 'SOIL AND MATERIAL TESTING LABORATORY ' • OF NORTH COUNTY. INC. —5— FIELD DENSITY TEST RESULTS. Date Test Re- Location Elev. Field Field Max. Riative of No. test of Test or. Moisture Density Dry Compaction • Test of Test Ht. of. 1111 Content (pci') Density (%) . . (%) (pcf) 1984 No. 2-25 1 Lot 238*2.0 11.7 . 110.5 117.0 :94.4 2 Lot 236 2.0 11.6 110.6 117.0 94 5 2-27 3 Lot 23 . 8.0 10.4 . 114.9 129.0 . 89.1 4 Lot 234 4.0 9.3 114.3 . 129.0 88.6. 5 Lot 237 4.0 11 1 116.6 129.0 90.4 6 Lot 235 4.0 10 5 120.6 129.0 .93 .5 7 4 Lot 234 4.0 11 2 1207 129.0 93.5 2-28 8 Lot 238 6.0 7.5 114.4 125.0 91.5 9 Lot 236 6.0 10.1 120 3 129.0 93.3 10 3 Lot 233 8.0 9.7 114.3 125.0 .91 .4 11 Lat 237 8.0 9.5 119.2 129 0 92.3. 12 Lot 238 10.0 10.3 111.3 l20.5 92 4 13 Lot 236 12.0 9.9 112.2 120.5. 93 1 14 Lot 235 10 ..0 9.3. 112 ..4 120.5' 93.3 15 Lot 233 12 0 8.1 111.5. 120.5 92 5 2-29 16 Lot 234 16 0 8.6 109 5 120 5 90.9 17 Lot 235 14.0 9.3 1.18 .8 125.0 95.0 18 Lot 237 16.0 10.3 119.9 129 0 93.0 19 Lot 238 14.0 8.0 11.7 .5 129.0 91.1 3-02 20 Lot 211 2.0 8.5 110.2 1.20 .5 91.4 21 Lot 211 4.-0. 8.12 110 0 120.5 91.3 22 Lot 212 3.-O 8.3 111 8 120.5 92.'7 23 Lot 233 18.0 9.2 111 3 120 5 92.4 24 • Lot • 238 . 18.0 90 :110.6 120.5 91.8 25 Lot 237 20.0 9.9* 118.0 129.0 91.5 SOIL AND MATERIAL TESTING LABORATORY • • • OP PdOTI.l COUPdrV. INC. • • . • -6- S FIELD DENSITY TEST RESULTS Date Teat Re- Location Elev. Field Field Max. Relative of No. ..test of Teat or Moisture Density Dry Compaction Teat . of Ht. of Content (pc?). Density (%) Test ' Fill (%) (pc?) - 1984 ' No. . 3-02 26 Lot 236 22.0 9 1 117.2 129.0 / 90.'9 27 ' Lot 235 20.0 8.0 1168 .129.0 90.5 28 Lot 233 22 0 11 .,0 120.8 129.0 93.7 29 Lot 211 8.0 10.1 109.1 120.5' 90 5 30 Lot 212 5.0 9.2 110.9 120.5 92.0 ,* 31 Lot 334 24 0 10.0 115.'2 120 5 95.7 3-03 32 Lot 233 28.0 9.4- 113.8 120.5 94.4 33 Lot 234 26 0 9.7 114 4 120.5 94 9 34 Lot 237 .24.0-* 9.1 120.3 129.0 93.2. 35 Lot 244 2.0 11.1. 116.9 125.0 93.5- 36. Lo-t 241 2.0 10.0 110.9 120.5 92 1- 37 Lot 243 4.0 10.0 111.0 120.5 92.2 38 Lot 240 4.0 .9.5. 109-.5 120.5 90.9 39 Lot 242 6-.0. 9 8 109.4- 120.5 90.8 40 Lot 244 6.0 10.2 109.9 120.5 91.2 41 Lot 232 13 0 9.6 111.1 120 ..5 92.2 42 Lot 211 12.0 11.1 112.6 120 .5 , 93.9 43 Lot 212 9.0 10.5 109.3 120.5 90 ..7 44 Lot 211 16 ..0 .11.1. 110 1 120 *.5 91.4 45 Lot 212 11.0 10.5 108.6 120A 90-.1 3-05 46 Lot 239 10 ..0 9.8 110.4 120.5 91.6 47 Lot 211 20.0 9.2 109.4 120.5 9.0 .8 48 Lot 240 8.0 9 6 112.5 120.5 93 4 49 Lot 242 10.0 9 7 111.5 120.5 92,5 • 50 . Lot 244 8.0 . 8.2 120.8 129.0 93.6 SOIL AND MATERIAL TESTING LABORATORY or Norm COUNTY. INC. -7- . FIELD DENSITY TEST RESULTS • Date Test Re- Location Elev. : F.isld Field Max. Relative of No. test of Test or Moisture Density • Dry Compaction • Test of Test. Ht. of FIJI Content (%) (pcf) Density (%) (pcf) 1984 No. .. 3-05 51 Lot 239 18.0 9.5 110.6 120 5 91 8 3-06 52 Lot 244 8.0 10.6 109.0 120.5 90 4 53 Lot 244 10.0 10 4 112.5 123.5 91.1 54 Lot 243 12.0 9.6 113 .6, 123.5 92.0 3-07 55 Lot 232 F C 6.3 108.7 120.5 90.2 333.0 • 56 Lot 233 F.C. 7.9 108.6 120.5 90.1 331.0 57 Lot 234 F C .10 .3 109.9 120.5 91 2 329.5 58 Lot 235 F C 11.1 110.2 120.5 91.4 328.5 59 Lot 236 F.-G. 8.4 116.5 1,29 .0 90.3 327.5 S • 60 Lot 237 • F.'C. 10.2. 1174 • 129.0 . 91.0 326.5 61 Lot 230 F C 9.5 102.7 120.5 85.2 337.0 • 62 Lot 228 F.C. 9.1 108.7 120.5 90.2.. 336.0 63 Lot 227 F.C. 7.4 116.4 129.0 90.2 • . • 329.0 • . . 64 Lot 231 F C 7.0 116.5 129.0 90.3 335.0 3-08 65 61 Lot 230 F C 10.1 111 8 120 5 92.7 337 0 66 Lot 226 F C 10.1 111.2 120.5 92.3 328.0 :. • • •• 67 Lot 225 F C 8.7 110 0 120.5 91.3 • • . • • • 327.0 • . . • • S 3-09 68 • Lot 224 • F.C. 7.8 • 108.6 120.5 90.2 • . 326.0 . • • SOIL AND MATERIAL TESTING LABORATORY F. G. =Finish Grade OF NORTH COUNTY. INC • • -8- 4 (S FIELD 'DENSITY TEST RESULTS Date Test Re- Location' Elev. F.ield F,ield Max. 'Relative of No. test of Test or' Moisture Density Dry Compaction Test of Test ' Ht. of Fill Content '(pcf) Density (%) (%) (pcf) 1984 - 3.-09 69 Lot 223 F.G. 10.4 119.1 , 129.0 92.3 3250 70 Lot 222 F C 9.2 114.5 120.5 95.0 324.Q 71 Lot 221 F.G. 9.8* 109.7 120.5 91.1 ' ' ' ' 322.0 ' 3-10. 72 ' Lot 238 F.C. ' 9.3 120.3 ' 129.0 ' ' 93.3- 325.5 73 Lot 216 .2.0, 9.4 105.3 117 0 90,0 74 Lot 216 4 0 9.2 105.9 117.0 90.5 75 Lot 216 6,0 11.4 111 7 123.5 90.4 76 Lot 216 8 0 10.0 105.5 117.0 90.2 77 Lo-t 229 F.G. 8.8: 122.6 129.0 95 0 338.0 S 78 Lot 239 F.G. 7.9 112.7 120.5. 93.5 324.5 79 Lot 240 F C 10.6 115.8 120 5 96.1 322.5 80 Lot 220 F.G. 14.2 ' 96.0 103.0, ' 93.2 319.0 3-12 81 , Lot 219 , , F.G. ' 8.9 ' 930 103.0 90.3 316.0 ' ' ' ' ' . 82 Lot 212 17.0 8.1 114.9 120.5 95.4 83 Lot 242 F C 10.1 118 8 129.0 92.1 315.5 84 Lot 241 F C 10.3 114.9. 120.5 95.4 319.5 85 Lot 211 24.0 10.6 112.6 123.5 91.2 3-13 86 Lot 243 , F.C. 10.0 118.8 • 123.5 96.2 312.0 F. G.'= Finish Grade SOIL AND MATERIAL TESTING LABORATORY OF NORTH COUPY. INC.' • ' -9- FIELD DENSITY TEST RESIki'S Date Test RI- Location Elev. Field Field Max. Rol etjve of No. test of Test . or Moisture Density Dry Compaction Test of . Ht. of Content (pcf) Density (%) • Test Fill : (pcf) 1984 .3-13 87 Lot 244 F.G. 9.2 111.1 120.5 92.2 (high pad) 309.0 88 Lot 244 F C 10.1 115 1 120.5 95.5 (low pd) . 306.0 . . 89 Kingston Rd. S.C. . . 8.5 110.9 120.5. 92.1 in front of 10 .. Lots 237-238. . . . . 90 . Kingston Rd. S.C. 8.3 111.9 . 120.6 92.'9 in front of 2.0 . ... . . Lot 240 . Lot 217 . .•: F.G. 11.6 108.5 . 117.0 92.7 (high pad) 312.5 . ,. . Lot 213 F.C. 8.6; 126.9 129.0 98.1 (high pad) 329.5 . . . . . . . 93. Lot 213 .. F.C. . . 9.0 117.3 125.0 91.0 (low pad) 326 5 • 94 Lot 214 F.G. 10.1 121.7 125.0 94.3 322.0 Lot 215 F.C. ., . 8.3 111.5 • 120.5 92.6 (high pad) 219.0 • . • . 96 . Lot 211 28.0 .9.4 109.5 120.5 90.9 97 Lot 212 21.0. 10.4 114.5 120 5 95.0 98 Lot 217 F.0 .10 .7 109.0 117.0 93 ..2 (low pad) 309.5 • .• • • 99 Lot 218 F C .10 .0 106.6 117.-0 91.1 313.0 •• • • 100 Lot 215 F.G. 8.6 97.2 103.0 94.4" (low pad) 316.0' 101 Lot 212 • 25.0 9.2 109.4 120.5 9b.8 102 Lot 211 32.0 10.4 110.8 120.5 91.9 S • • S.C. = Subgrade • . • . • • • . • F.C. = Finish Grade • . • . • SOIL AND MATERIAL TESTING LABORATORY • • •• . . a. NORTH couNrv. INC. • . • -ib.- . FIELD DENSITY TEST RE SIc Date test. Re- Location Elev. Field . Field Max. Relative of No. test. of Test . or Moisture Density Dry Cdmpaction. Test of ., .. Ht. of Content (pcf) Denélty .1984 .T est . .. Fill . •(%) (pcf) 3-13 • 103 . •. ., Lot 216 . F. G. 11.1 116.7 12.5 95 . 311.5 .. . . 104 Victoria St. 2.0 9.9 1096 120.5 91.8 Interection . . . . • . . . . E1 . . . . 3-14105 . Victoria St. 4.0 10.1 111.5 . 120.5 92.5 between . . . . Kingston Elm. . ... . S •• • • 106 Victoria St. 6.0 . 9.8 110.0 120.15 91.3 between .. . . . . Kingston & . . . . • . . . Elm • . . .. 107 Victoria St 8.0 11 2 114.9 . 123 5 93 1 between- Kingston . . . •• . & . .,. •• S . . . .. . Elm 108 Lot 207 F C ..8.8 . 108.8 120.5 90.2 329.5 • .: 109 Lot 208 F C. 8.5 110 3 120 5 91 5 (high pad) 326.5 110 Lot 208 F C 9 3 117 5 129.0 91.2 (low pad) . 323.5 • ill Lot 209 • F.C. 10.6 118.9 :1290 92.2 321.8 .. . • 112 Victoria St 1 0 9.1 109.7 120.5 91.0 between . . S S Kingston ,& Elm 113 Lot 211 F C .8 .7 108.9 120.5 90.4 . 313.0 . 114 Lot 212: • • F.G. 9.0 109.9 120.5 . 91.2 310.5 115 Lot 210 F C 9.2 109 4 120.5_- 90.8. (high pad) . 318.0 5 . F C Finish Grade SOIL AND MATERIAL TESTING LABORATORY OIr NOAT" COUNTY. INC. 1 FIELD DENSITY TEST RESULTS Date Test Re— Location Elev. F.ield Field Max. Relative of No. test of Test. or Moisture Density Dry Compaction Teat of Ht. of Fill Content (pcf) Density (%) N Test M (pcf) 1984 3-14 116 Lot 210 F C 9.9 .110.5 120.5 91.7 * (low pad) 315.0 3-15 117 Victoria St S.C. 8.6 112.2 120.5. 93 .*2 Sidew1k 3.0 118 Victoria St S.C. 10.5 113.1 120.5 93.9 Sidewalk 14.0 119 Victoria St S.G. 9.6 109.7 120.5 91.0 at Intersection 3.0 of Kingston CT8.-iq : 0 17 Gal. 1 44 10 \ \ . 229 -230 3I 232or's 23 j \ \ 233 32 \ \ AUBURN •. ' . " \ \ AVE. . 234.' ç j4- 228 062 235 B 9\ 2 . 236 000 S ., 3: . 226 237 roo • I . . 5,- '.5 . S 238 44 2 4 239 . 0 . / \. ' ,' - 5-.- - .. ." 48 2 240 4~ ILI• - 70 90 ..64- Nr - - .. 241 ..\ V 71 , • ' . - '..• 21 242 - A .. 60 .863 / :__•_____4_ ----r-- .. .. -- 243 "S/... -___ S8C • \,. 60.. - .. .5 . - " 29 •• 31 4/ AD - - 8) . S -, 1/8 2 • -''. LEGEND S S S...' /\ ol - FILL.'-AREA TESTED . . .• 73 I 5 1 . EE AREA UNDERCUT I A007, RIPPED I ' 96 /19 1' .W4TERED AND: RECOMPACTED .1 - \... L. — - ••.. - . / fr.5 111111 il A REI4 RIPPED 1 7 WA TERED ' IL I I I / 11 IA NO IEcOM P CTE •.:. .. - ry 40' SLOPE BAN/< 212 - VIOTORIP.82 FIELD DENSITY TEST 097 0 0 . .. -. Lta. — -42 0 . S . 579 - 211 '' 8 9 IO28 20. 2•/j .111 . / • .T. . CARLSBAD TRACT 82-14 TEMPLIN HEIGHTS UNIT NO. 3. SOIL & MATERIAL TESTING LABORATORY OF NORTH COUNTY • PLOT PLAN APPROXIMATE SCALE 1 It= ioY JOB NO. 83-J FIGURE NO. I