Loading...
HomeMy WebLinkAboutCT 82-14; TEMPLIN HEIGHTS; FIELD DENSITY TESTS; 1984-08-15 (2)LT ______ - •CT L-11t(03) SOIL AND MATERIAL TESTING LABORATORY OF NORTH COUNTY. INC. - 15 August 1984 423 HALE AVE. - EScONDIDO. CALIF. 92025 ESCONDIDO - 746-2333 McMillin DevelopmentCompany 2727 Hoover Avenue National City, California 92050 Attention: Mr Ed Elliot RE:Job No. 83-58 Tern hts Un arlsbad Tract No. 74-14(A) and Off site Access for Carlsbad Tract 82-12 Carlsbad, California Dear Mr. Elliot: At the request of Mr. Robert Olimon, we have performed field density tests in the subgrade and base in the above referenced project. The field density tests were done in accordance with ASTM 0-1556, the sand cone method. The results of our observations field density and laboratory tests indicated compacted subgrade and base has been placed at not less than 90% and 95% of. the maximum dry density., respectively. The laboratory compaction tests used to determine the maximum dry density and optimum. moisture content of the above tests were performed in accordance withASTM 0-1557-70, method C. . A summary of the test results is presented on the following pages. Respectfully submitted, SOIL AND MATERIAL TESTING S S S LABORATORY OF NORTH COUNT.Y, INC. E. BRIAN SMITH, RCE 13,817 EBS:svh S. SOIL AND MATERIAL TESTING LABORATORY OF NORTH COUNTY.-INC. -2- 83-58 SUBCRADE FIELD DENSITY TEST RESULTS Date- Test Re- Location 'Ht.-of Field Field Max. Rlatjtje of ...No. test. of Test Fill Moisture Density Dry Compéction Test of Tested Content (pcf) Density (%) Test (feet) (%). (pcf) 1984 No. 8-01 1 ' Victoria Avenue S.C. 3.8 110.1 120.5 91.4' STA •8+50 South Side ., 2 VictOria Avenue S.C. 12.8 109.1 117.0 . 93.2 STA 10+50 . . North Side 3 Victoria Avenue S.C. 6.4 110.0 120.5 91.8 STA 12+90 :' . . . South Side 4 Kingston Street S.C. 7.8 1.09.4 117.0 93.5 STA 2+00 West Side Kingston Street S.C. 5.3 110.2 ' 120.5 91.5' STA 4+60. : I Center 6. King s ton Street S.C. 4.2 112.3 120.5 93.3 STA 7+00 West Side " 8-02 7 ' Kingston Street S.C. 6.9 110.9 ' 120.5 92.1 STA 9+50 Center . 8 ' ' Elm Avenue S.C. 11.1 ' 108.8 117.0 ' 93.0 STA 43+00 West Side 9 Elm Avenue S.C. 99 . 108.5 " 117.0 92.8 ST 45+50 East Side 10 : ' ' Elm Avenue , , S.C. 7.8 " 112.7 '120.5 93.7 ' STA 48+00 ' ' • ' ' I . ' ' ' West Side 11 ' Elm Avenue ' S.C. ' 8.7 ' 1129 120.5 93.4 STA 51+50 • , ' • ' " ' ', ' ' ' East Side S.C.' = Subgrade 'SOIL AND MATERIAL' TESTING LABORATORY • OF NORTH COUNTY. INC. , ' ' ' • -3- • SUBCRDE 83-58 • FIELD DENSITY TEST RE$U(.TI Date Test Re— Location Depth Field Field Maximum Relative of No. test of Test Below Moisture Density Dry Compactic Test of Lot No. Ex.Cr. Content (pc?) Density () Test Tested (%). (pc?). - 1984 No. (feet) 8-02 12 • • Elm P.ienue S.C. 10.5 113.6 120.5 94.3 STA 53+00 • • West Side • 83-58 BASE 0 FIELD DENSITY TEST RESULTS Date- Test Re- Location lit. of Field Field Max. Relative of No. test of Test Fill Moisture Density Dry Compaction Test of Tested Content (pcf) Density (%) Test (feet) (%) ': " ' (pcf) 1984 ' No. 8-03 1 Victoria' Avenue F.G. 5.8 132.6 133.6 , 99.2 '. ' STA 8+50 North, Side . 2 Victoria Avenue. F.G. '9.9 121.9 133.6 91.3 • . ' STA 11+50 . . • ' South Side 3' . Kingston' Street F.G.- 5.8 131.7 133.6 98.6 STA 2+00 East Side . ' . 4 Kingston Street ' F.C. 6.2 130.4 ' 133.6 97.6 ST'A 4+50 West Side 5 Kingston Street F.C. , 6.6 128.5 133.6 '96.2 STA 7+00 Center 6 , Kingston Street F'.C. 5.6 129.0 ' :133.6 96.6 STA 9+50 East Side . ' • 7 2 ' , Victoria Avenue' ' F.G. 6.8 128.1 133.6 95.,9 'STA 11+50 . • South Side 8-06 8 ' Elm Avenue E.G. 5.8 139.6 141.0 99.0 ' STA 44+50 . ' ' ' • West Side , ' • 9 • Elm Avenue E.G. '6.0 ' 139.6 141.0 99.0 STA 47+00 • ' ' East Side • • • 10 Elm Avenue , E.G. ' 6.1 139.6 141.0 99.0 STA 49+50 ' ' ' ' Center , • • 11 , ' Elm Avenue E.G. 7.0 139.1 141.0 98.7 • STA 52+00 ' • '' ' North Side E.G. = Finish Grade , ' • SOIL AND MATERIAL TESTING LABORATORY ' OF NORTH COUNTY. INC. -5- ' 83-58 BASE FIELD DENSITY TEST RESULT3 Date Test Re- Location 'Depth Field Field Maximum 'Relative or , No. 'test of Test ' Below Moisture. Density 'Dry Compactia Test : :°' Lot No. ' (x.Gr. Content (pcf) Density (%') Test ' ' Tested , (%) ' (pcf) 1984 No. ' (feet) 8-6 12 Elm P1venue F C 6 4 138.1 141 0 - 98.5 STA 54+00 South Side F.C. Finish Grade SOIL AND.MATERIAL TESTING LABORATORY ' •:' ' —6— '