Loading...
HomeMy WebLinkAboutDEV 2016-0070; DEMPSEY RESIDENCE; RESPONSE TO CITY OF CARLSBAD COMMENTS; 2017-08-02CTEjnc Construction Testing & Engineering, Inc. Inspection | Testing | Geotedmical | Environmental & Construction Englneerfng | Civil Engineering | Suveyir^ August2, 2017 CTE Project No. 10-1343 5G Attention: Mr. John Dempsey 1835 Aston Avenue Carlsbad, California 92008 Telephone: (760) 822-5290 Via Email: id@dempseyconstruction.com Subject: Response to City of Carlsbad Comments Proposed Dempsey Residence APN: 215-491-36-00, Bolero Street Carlsbad, California Reference: Wall Details (Sheet 3) Dempsey Residence Lot 46 Bolero Street Carlsbad, CaUfomia Prepared by CTE, Inc. Geotechnical Investigation Proposed Dempsey Residence APN: 215-491-36-00, Bolero Street Carlsbad, CaUfomia CTE Job No. 10-13435G, dated December 30, 2016 Mr. Dempsey: As requested. Construction Testing & Engineermg, Inc. (CTE) provides the response herein to plan comments fipm the City of Carlsbad. CTE understands that the City is concerned that the setback/distance-to-dayUght for the lower retaining waU depicted in Section C of the referenced plan sheet is not in conformance with the recommended setback in the referenced geotechnical report (The report recommended a minimmn setback of 15 feet from the face of nearest slope, while the plan section shows a setback of approximately nine feet from face of slope.) Based on review of CTE boring logs and site observations, CTE anticipates that at the planned footing embedment depth shown on the plans, the lower retaining waU wUl be embedded into competent native materials, and as such, a minimmn distance to daylight of seven feet is considered appropriate. However, and as recommended in the referenced report, CTE should observe the bottom of this and aU excavations to determine if adequate bearing materials are exposed, and CTE reserves the right to recommend deepening of footing excavation in the field based on om: observations. 1441 Montle! Road, Suite 115 | EscondkJo, CA 92026 | Ph (760) 746-4955 | Fax (760) 746-98(» | www.cte4nanet Response to City of Carlsbad Comments Proposed Dempsey Residence APN: 215-491-36-00, Bolero Street Carlsbad, California August 2, 2017 Page 2 CTEJobNo.: 10-13435G This letter is subject to the same limitations as previously issued geotechnical documents for this project. We appreciate the opportunity to be of service on this project. Should you have any questions, please contact our office. Sincerely, CONSTRUCTION TESTING AND ENGINEERING, INC. Dan T. Math, GE# 2665 Principal Engineer 12/31/18 Colm J. Kenny, RCE# 84406 Project Engineer 84406 9/30/17 \\Esc_servei\projects\10-13435G\Ltr_Foundation Setback-doc