Loading...
HomeMy WebLinkAbout57C0191; Agua Hedionda Creek; El Camino Real; 2007-04-04Gx/fransf DEPARTMENT OF TRANSPORTATION Structure Maintenance & Investigations Bridge Inspection Report Bridge Number : Facility Carried: Location : City : Inspection Date : Inspection Type 57C0191 EL CAMINO REAL 3.1 MI S ROUTE 78 CARLSBAD 04/04/2007 Routine FC Underwater Special Other B D D D D STRUCTURE NAME; AGUA HEDIONDA CREEK CONSTRUCTION INFORMATION Year Built : 1971 Year Widened: N/A Length (m) : 34.4 Skew (degrees): Wo. of Joints : No. of Hinges : Structure Description: Three simple PC/PS concrete deck units (18) with continuous composite CIP/RC deck slab spans on two open end RC seated abutments supported on concrete piles and on two RC pile (14) bents. Span Configuration : (W) 3 @ 11.3 m (E).c/c LOAD CAPACITY AND RATINGS Design Live Load: MS-18 OR HS-20 Inventory Rating:32.6 Operating Rating: 57.1 Permit Rating : PPPPP Posting Load : Type 3 metric tons metric tons N/A Calculation Method: LOAD FACTOR Calculation Method: LOAD FACTOR Type 3S2 N/A Type 3-3 N/A DESCRIPTION ON STRUCTURE Deck X-Section: (S) 0.3m br, 12.0 m, 1.2m med, 18.8 m, 0.3 m br (N) Total Width: 33.5m Net Width: 32.9 m Rail Description: Type 9-11 Railing Min. Vertical Clearance: Unimpaired No. of Lanes: 6 Rail Code : 0000 DESCRIPTION UNDER STRUCTURE Channel Description: Natural, well defined & weed filled w/ rip rap at the abutments. CONDITION TEXT CONDITION OF STRUCTURE ;. There are transverse and longitudinal cracks, moderate in size and density throughout the deck. The northerly concrete barrier has crushed at easterly end and one bolt has missing from the northerly east corner. Otherwise, the structure appears in good condition. ELEMENT INSPECTION RATINGS F#Elem Element Description 101 101 101 101 101 101 101 38 205 215 227 234 312 335 Concrete Slab - Bare Reinforced Cone Column or Pile Extension Reinforced Cone Abutment Reinforced Cone Submerged Pile Reinforced Cone Cap Enclosed/Concealed Bearing Other Bridge Railing Env Total Units Qty 2 2 2 2 2 2 2 1120 sq.m. 28 ea. 67 m. 1 ea. 66 m. 2 ea. 87 m. Qty in each Condition State St. 1 St. 2 St. 3 St. 4 St. 5 1120 28 67 1 66 2 86 0 0 0 0 0 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Printed on: Wednesday 05/02/2007 01:53 PM 57C0191/AAAF/10836 F#Elem 101 358 Element Description Deck Cracking Env 2 Total units Qty 1 ea. Qty in St. 1 St. 0 each Condition 2 St. 3 St. 0 0 State 4 St. 1 5 0 WORK RECOMMENDATIONS RecDate: 07/30/2004 EstCost: Action : Deck-Methacrylat StrTarget: 2 YEARS Work By: LOCAL AGENCY DistTarget: Status : PROPOSED EA: Seal the deck cracks with methacrylate. Inspected By M. Zaarour/ A. Shenouda Registered Civil Engineer Printed on: Wednesday 05/02/2007 01:53 PM 57C0191/AAAF/10836 STRUCTURE INVENTORY AND APPRAISAL REPORT IDENTIFICATION (1) (8) (5) (2) (3) (6) (7) (9) (11) (12) (13) (16) (17) (98) (99) STATE NAME- CALIFORNIA STRUCTURE NUMBER INVENTORY ROUTE (ON/UNDER) - HIGHWAY AGENCY DISTRICT ON 069 57C0191 1500S3440 11 COUNTY CODE 073 FEATURE INTERSECTED- FACILITY CARRIED- LOCATION- (4) PLACE CODE 11194 AGUA HEDIONDA CREEK EL CAMINO REAL 3.1 MI S ROUTE 78 MILEPOINT/KILOMETERPOINT 0 BASE HIGHWAY NETWORK-. NOT ON NET 0 LRS INVENTORY ROUTE & SUBROUTE LATITUDE 33 DEG 08 MIN 56 SEC LONGITUDE 117 DEG 17 MIN 49 SEC BORDER BRIDGE STATE CODE % SHARE % BORDER BRIDGE STRUCTURE NUMBER STRUCTURE TYPE AND MATERIAL (43) STRUCTURE TYPE MAIN:MATERIAL- PRESTRESS CONC TYPE- SLAB CODE 501 (44) STRUCTURE TYPE APPR:MATERIAL- TYPE- CODE (45) NUMBER OF SPANS IN MAIN UNIT 3 (46) NUMBER OF APPROACH SPANS 0 (107) DECK STRUCTURE TYPE- CIP CONCRETE (108) WEARING SURFACE / PROTECTIVE SYSTEM: A) TYPE OF WEARING SURFACE- NONE B) TYPE' OF MEMBRANE- NONE C) TYPE OF DECK PROTECTION- NONE *************** AGE AJJD SERVICE *************** (27) YEAR BUILT 1971 (106) YEAR RECONSTRUCTED 0000 (42) TYPE OF SERVICE: ON- HIGHWAY 1 UNDER- WATERWAY 5 CODE CODE CODE CODE 06 UNDER STRUCTURE 00 22000 3 % 16 KM (109) TRUCK ADT (28) LANES:ON STRUCTURE (29) AVERAGE DAILY TRAFFIC (30) YEAR OF ADT 1990 (19) BYPASS, DETOUR LENGTH *************** GEOMETRIC DATA **************** (48) LENGTH OF MAXIMUM SPAN 11.3 M (49) STRUCTURE LENGTH 34.4 M (50) CURB OR SIDEWALK: LEFT 0.0 M RIGHT 1.2 M (51) BRIDGE ROADWAY WIDTH CURB TO CURB 32.9 M (52) DECK WIDTH OUT TO OUT 33.5 M (32) APPROACH ROADWAY WIDTH (W/SHOULDERS) 32.9 M (33) BRIDGE MEDIAN- CLOSED (NO BARRIER) 2 (34) SKEW 0 DEG (35) STRUCTURE FLARED NO (10) INVENTORY ROUTE MIN VERT CLEAR 99.99 M (47) INVENTORY ROUTE TOTAL HORIZ CLEAR 18.8 M (53) MIN VERT CLEAR OVER BRIDGE RDWY 99.99 M (54) MIN VERT UNDERCLEAR REF- NOT H/RR 0.00 M (55) MIN LAT UNDERCLEAR RT REF- NOT H/RR 0.0 M (56) MIN LAT UNDERCLEAR LT 0.0 M *************** NAVIGATION DATA *************** (38) NAVIGATION CONTROL- NO CONTROL CODE 0 (111) PIER PROTECTION- CODE (39) NAVIGATION VERTICAL CLEARANCE 0.0 M (116) VERT-LIFT BRIDGE NAV MIN VERT CLEAR M (40) NAVIGATION HORIZONTAL CLEARANCE 0.0 M (112) (104) (26) (100) (101) (102) (103) (105) (110) (20) (21) (22) (37) SUFFICIENCY RATING = 79.0 STATUS STRUCTURALLY DEFICIENT HEALTH INDEX 100.0 PAINT CONDITION INDEX = N/A ************* CLASSIFICATION ************* NBIS BRIDGE LENGTH- YES HIGHWAY SYSTEM- NOT ON NHS FUNCTIONAL CLASS- OTHER PRIN ART URBAN DEFENSE HIGHWAY- NOT STRAHNET PARALLEL STRUCTURE- NONE EXISTS DIRECTION OF TRAFFIC- 2 WAY TEMPORARY STRUCTURE- FED. LANDS HWY- NOT APPLICABLE DESIGNATED NATIONAL NETWORK - NOT ON NET TOLL- ON FREE ROAD MAINTAIN- CITY OR MUNICIPAL HIGHWAY AGENCY OWNER- CITY OR MUNICIPAL HIGHWAY AGENCY HISTORICAL SIGNIFICANCE- NOT ELIGIBLE **************** CONDITION *** (58) DECK (59) SUPERSTRUCTURE (60) SUBSTRUCTURE (61) CHANNEL & CHANNEL PROTECTION (62) CULVERTS CODE Y 0 14 0 N 2 0 0 3 04 04 5 CODE 4 7 7 9 N ********* LOAD RATING AND POSTING ********* CODE (31) DESIGN LOAD- MS-18 OR HS-20 5 (63) OPERATING RATING METHOD- LOAD FACTOR 1 (64) OPERATING RATING- 57.1 (65) INVENTORY RATING METHOD- LOAD FACTOR 1 (66) INVENTORY RATING- 32.6 (70) BRIDGE POSTING- EQUAL TO OR ABOVE LEGAL LOADS 5 (41) STRUCTURE OPEN, POSTED OR CLOSED- A DESCRIPTION- OPEN, NO RESTRICTION CODE (67) (68) (69) (71) (72) (36) (113) . (75) (76) (94) (95) (96) (97) (114) (115) (90) (92) A) **************** APPRAISAL *************** STRUCTURAL EVALUATION DECK GEOMETRY UNDERCLEARANCES, VERTICAL & HORIZONTAL WATER ADEQUACY APPROACH ROADWAY ALIGNMENT TRAFFIC SAFETY FEATURES SCOUR CRITICAL BRIDGES ********** PROPOSED IMPROVEMENTS ********* TYPE OF WORK- CODE LENGTH OF STRUCTURE IMPROVEMENT BRIDGE IMPROVEMENT COST ROADWAY IMPROVEMENT COST TOTAL PROJECT COST YEAR OF IMPROVEMENT COST ESTIMATE FUTURE ADT 30000 YEAR OF FUTURE ADT 2015 7 9 N 9 8 0000 5 M *************** INSPECTIONS ********** INSPECTION DATE 04/07'(91) FREQUENCY CRITICAL FEATURE INSPECTION: (93) FRACTURE CRIT DETAIL- NO MO A) 24 MO CFI DATE B) UNDERWATER INSP- NO MO B) C) OTHER SPECIAL INSP- NO MO C) Printed on: Wednesday 05/02/2007 01:53 PM 57C0191/AAAF/10836