Loading...
HomeMy WebLinkAboutCDP 04-58; Namekokopelli Residence; Hydrology/hydraulic study; 2005-10-24A Tri'Dimensional Engineering. Inc, ENGINEERING • PLANNI HG • SUR V E YING HYDROLOGY/HYDRAULIC STUDY Kokopelli Residence Lot 117 Map 3312-Northeast corner of Cerezo Dr. and Carlsbad Boulevard Carlsbad, San Diego County California. APN #210-111-08 Prepared for: George Pagliaro 1 Calle Alumbrado San Clemente, CA 92013 And the City of the Carlsbad Prepared by: Tri-Dimensional Engineering, Inc. October 24, 2005 P. O. Box 791 Poway, CA 92074 • (858) 748-8333 - Fax (858) 748-8412 . Ipil ir ICQ < October 25, 2005 Table of Contents Cover Sheet Table of Contents Summary and Findings Introduction Scope and Purpose Calculation Methods Existing Watershed Contribution Summary of Analysis Conclusions Declaration of Responsible Charge 3-5 3 3 4 4 5 6 6 Maps Exhibits and Appendices Drainage Map 'A' - Existing Conditions Drainage Map 'B' - Post Construction Drainage Map 'C - Subarea Designations Appendix A - Hydrology & Hydraulic Calculations (Complete Results) Appendix B - Charts, Graphs, Formulas, Tables used in design Appendix C - Detailed Hydraulic Calculations Appendix D - Detention Pipe Design Appendix E - Pump Design October 24, 2005 INTRODUCTION: The site is Lot 117 of Map 3312. It is 0.17-acre squared shaped and is located at the comer of Cerezo Dr. and Carlsbad Boulevard in Carlsbad. This lot is currently vacant. Its topography has 5 feet differences in elevations. It varies between 200 and 205 feet (MSL).It consists of gentle terrain sloping to the south towards the street (6% slope average). SCOPE AND PURPOSE; This is a hydrology/hydraulic study to determine existing runoff and post construction conditions. We will keep direction and amount of runoff discharge from this property by using a detention pipe. We will detennine the adequacy of the proposed pipes, drains, and Pump and detention pipe in the event of a time-of-concentration 100-year-storm. (See Drainage Map 'A', Drainage Map 'B', Drarnage Map 'C, Appendix A - Flow Characteristics Charts Appendix D - Detention System Design, Appendix E - Pump design. October 24,2005 CALCULATION METHODS: The Rational Method was used to determine total flow quantity at time of concentration for a 100-year-storm for each critical area. Where noted, the following equation was used to calculate time of concentration: T - 0 385 {n.9){Ly H (plus 10 min for natural channels) Where noted, the following equation was used to calculate rainfall intensity: / = 7.44(pj(Z))-''645 Where noted, the manning equation, as follows, was used to determine flow quantities and sections of flow: Qcap = A * V, where V = (1.49/n)*r^^^*s^^^ Where noted, the following equation was used to approximate coefficient of runoff, C, for drainage areas with multiple coefficients: C = [(CArea l)(AArea l)+(CArea2)(AArea2)+. - •] / [AAreal+AArea2+. • •] Where needed, the Bernoulli equation (along with Q=AV above) was used to determine flow characteristics: pi/y + Zl + v2/2g = P2/Y + Z2 + V^/2g + hL EXISTING WATERSHED CONTRIBUTION: The site, Lot 117 of Map 3312 contains 0.17 acres. The existing runofif from this property flows to Carlsbad Blvd. and Cerezo Dr. and is collected in a Curb Inlet located at the Comer of Cerezo Dr. and Carlsbad Boulevard on Carlsbad Boulevard. (See Drainage Map 'A'). October 24,2005 SUMMARY OF ANALYSIS: Once pre & post-constmction total storm flow rates were determined, flow sub-areas were analyzed to determine the 100-year-storm flow for each sub-area. Please refer to Drainage Map 'C for hydrology drainage sub-areas. The attached excel data sheets stommarize the hydrologic and hydrauUc data. Conditions were analyzed for (1) H&H, (2) detention system adequacy, (3) Pump requirements. (1) Peak flows were analyzed and appear in tihe attached 'Hydrology' chart (Appendix A). (Hydraulic analysis appears on the following page) (See Appendix C for detailed results for each pipe section). Refer to Drainage Map 'C for sub-area locations. (2) The Detention System was designed so that the maximum discharge rate from the site would remain tihe same as it was prior to constmction (See Map'A' for existing Conditions and Map B for Proposed conditions). See Appendix A for Q Characteristics and Appendix D for Detention system design. (3) Pump reqviirements (see Appendix E for pump sizing calculations). October 24, 2005 CONCLUSIONS: This study indicates that, if the project is constmcted per plan, the storm drain system at the subject site will be adequate to handle 100-year-storm conditions. Modifications to the proposed system would warrant a re-evaluation of the hydraulics by Tri-Dimensional Engineering, Inc. DECLARATION OF RESPONSIBLE CHARGE: I hereby declare that I am the Civil Engineer of work for this project, that I have exercised responsible charge over the design of the project as defined in section 6703 of the Business and Professions Code, and that the design is consistent with current standards. I imderstand that the check of the project drawings and specifications by the City of Carlsbad is confined to a review only and does not reheve me, as engineer of work, of my responsibilities for project design. Ernest H. Grabbe Jr. RCE 047327 Date October 24, 2005 Maps, Exhibits and Appendices EXISTING CURB INLCT- LEGEND ITEM PRE-CONSTRUCTION UNDISTURBED C COEF. AND ACREAGE FOR SUB-BASINS tJS SYMBOL QTY. 0.17 AC LOT AREA 100% SUBASIN Tri-Dimensional Engiheering, Inc. ENGINEERING ° PLANNING » SUR VB YING JVJAF 3371 EXISTING 5 FT. PACIFIC TELEPHONE & TELEGRAPH CQ. ACCESS AND UTIUTIES CASEMENT REC. FEBRUARY 6, 1956 IN BK. 5966, PG. 95 OF 0,R. EXISTING 6 FT. SDG&E _ACCESS AND UTILITIES EASEMENT REC. JUNE I, 1956 IN BK. 6124, PG. 178 OF O.R. LOT 137 JVJAF 3371 Q 0.28 CFS EXISTING CONDITIONS DRAINAGE MAP 'A' SCALE: 1"=20' P.O. BOX 791 POWAY, OA 92074 (858)748-8333 FAX (858)748-8412 —1 cq 1 Q I O I LEGEND ITEM POST-CONSTRUCTION IMPERVIOUS C COEF. AND ACREAGE FOR SUB-BASINS 116 SYMBOL QTY. 0.10 AC LOT AREA 59 % Q 0.71 CFS SUBASIN 'C AREA loo MAP 3371 EXISTING 5 FT. PACIFIC TELEPHONE Sc TELEGRAPH CO. ACCESS AND UTIUTIES EASEMENT RCC. FEBRUARY 6, 1956 IN BK. 5966, PG. 95 OF O.R. EXISTINC 6 fT. SDG&E ^ACCESS AND UTILITIES EASEMENT REC. JUNE 1, 1956 IN BK. 6124, PG. 178 OF O.R. LOT 137 MAP 3371 CBPi^ZO Dl POST-CONSTRUCTION IMPERVIOUS AREAS DRAINAGE MAP 'B' SCALE: r =20' i \ Tri'Dimensional Engineering.Jnc. P.O. BOX 791 POWAY, GA 92074 (858)748-8333 FAX (858)748-8412 October 24, 2005 Appendix A Hydrology and Hydraulic Calculations Hydrology - Determine Tc and Q Natural Flows Pipe/Urban Flows (5m min) (P=2.5) Flow ID H L Time (nat) Vel Dist Time (urb) Tc Total 1 C A Qmax (ft) (ft) (min) (fps) (ft) (min) (min) (in/hr) (acres) (cfs) Z use min time of concentration 5.00 6.59 0.25 0.17 0.280 F use min time of concentration 5.00 6.59 0.63 0.17 0.705 use mm time of concentration 5.00 6.59 0.95 0.03 0.188 B use min time of concentration 5.00 6.59 0.72 0.05 0.237 C use min time of concentration 5.00 6.59 0.65 0.01 0.043 D use min time of concentration 5.00 6.59 0.51 0.05 0.168 A+B+C+D use min time of concentration 5.00 6.59 0.69 0.14 0.636 E use min time of concentration 5.00 6.59 0.25 0.01 0.016 F use min time of concentration 5.00 6.59 0.25 0.01 0.016 Flow Characterist cs - Hydraulics of Pro posed Structures Results Flow ID Flow Description Pipe Siz6 (in) Slope (dec) n Chnnel Btm wdth(ft) Lt side slope Rt side slope Slope (dec) n Design Q (cfs) Depth (ft) Vel (fps) Top width (ft) Z LOT PRE-CONDITIONS 0.28 F A LOT POST-CONDITIONS FORCE MAIN 0.71 0.19 B 6"PVC@1% 6 0.010 0.013 0.24 0.23 2.75 C 4" PVC @ 2% 4 0.020 0.013 0.04 0.09 2.21 D BROOKS CB. 0.17 DETENTION BASIN OUTLET 4 9.200 0.013 0.24 0.15 6.31 E DIRECT DISCHARGE TO ST. 0.02 F DIRECT DISCHARGE TO ST. 0.02 Notes EXIST. RUNOFF FUTURE RUNOFF DETENTION PIPE October 24, 2005 Appendix B Charts, Graphs, Equations, Tables used in Design, Other Calculations Directions for Application: fn?thS'''i^^i''^" ""^P" determine 6 hr and 24 hr amounts (2) Adjust 6 hr precipitation-(if necessaiy) so that it is within (3) Plot 6 hr precipitallQn on the right side of the chart (4) Draw a line through the" point parallel to the plotted lines Ltg rn^yS"''""^-'"^^"" ^"^^ Application Form: (a) Selected frequency lOo year i"-.P24=-4!^-.B— (c) Adjusted Pg(2) = '^g' jn 24 Note: This chart replaces the Intensity-Duration-Frequencv curves used since 1965. n nuquency 2.5 5.30 4.21" 2.59 3.24 i'l 51'ies i.87[2.'33 1.66] 2.07 1.38 '1.72 1.49 1.33 1.02 0.85 0>3 0.65 0.54 I 3.5 •[•-.,.-7.90 6"36 6747 '6A2 5.05 3.89 3.23 2.'8d 2.49 2.07 i.79 1.59 'i'.'23 "l.02 0.88 0.78 0.65! 6.56 6750 9.22 7.42 5.90 4.54 377: '3.27 J 2.90 2.41 2.09 1.86 1.43 1.19 1.03 0.91 0.76 6.66 6.58: 4 ' 4.5" I , I ,10.54111.86- 5.5 I 8.48 6;74 5.19 4.31"! 3.32 2.76 2.39 2.12 1.63 1.36 1.13 1.04 0.87 6.75 0.67 9.54 7.58' 5.84 1 4.851 "4.20! 3.73 ' 3.10 ' 2.69 ! 2.39 . 1.84 ' 1.53 '. 1.321 1.18 j 0.98 I 0.85 13.17'14.49: lo.eo'li.eel 8.4i2 I 9.27" 6.49 . 7.13 I '5.39 I 5.93 4.67 i 5.13 i 4.15 I 4.56 • 3.45 j 3.79 ' 2.98 ! 3.28 ' 2.65 2.04 1.70 1.47 2.92 2.25 1.87 1.62 1.31 1 1.44 1.08 • I.I9 • 0.94 •' 1.03 ' 0.75 .' 0.84 ! 0.9? 15.81 12772 Vo.'u 7.78 6.46 5.60 4.98 4.13 3.58 3.18 2.45 2.04 1.76 1.57- 1.30 i.'l3 i.OO intensity-Duration Design Chart - Template HazMal/County ri,..-deolpgy Manual/lnt_Uur Design Charl.FHB Table 3-1 RUNOFF COEFFICIENTS FOR URBAN AREAS Land Use NRCS Elements Undisturbed Natural Terrain Low Low Low Medium Density Residential Medium Density Residential Medium Density Residential Medium Density Residential High Density Residential High Density Residential Gondmercial/Industrial , .Commercial/Industrial Commercial/Industrial Commercial/Industrial Commercial/Industrial County Elements Permanent Open Space Residential, 1.0 DU/A or less Residential, 2.0 DU/A or less Residential, 2.9 DU/A or less Residential, 4.3 DU/A or less Residential, 7.3 DU/A or less Residential, 10.9 DU/A or less Residential, 14.5 DU/A or less Residential, 24.0 DU/A or less Residential, 43.0 DU/A or less Neighborhood Commercial General Commercial Office Professional/Commercial Limited Industrial General Industrial % IMPER. 0* 10 20 25 30 40 45 50 65 80 80 85 90 90 95 Runoff Coefficient "C" 0.20- 0.27 0.34 0.38 0.41 0.48 0.52 0.55 0.66 0.76 0.76 0.80 0.83 0.83 0.95 Sqi.lType 0.25 0.32 0.38 0.41 0.45. 0.51 0.54 0.58 0.67 0.77 0.77 0.80 0.84 0.84 0.95 0.30 0.36 0.42 0.45 0.48 0.54 0.57 0.60 0.69 0.78 0.78 0.81 0.84 0.84 0.95 D 0.35 0.41 0.46 0.49 0.52 0.57 0.60 0.63 0.71 0.79 0.79 0.82 0.85 0.85 0.95 forever (e.g.. the area is located in Cleveland National Forest). ""^'^^^''^^'l Perpetuity. Justification musl be given that the area will remain natural DU/A = dwelling units per acre NRCS = Natfonal Resources Conservation Service AE I Feet Tc = EQUATION 0.385 -5000 .4000 • 3Q0Q -2000 Tc L AE Time of concentration (hours) Watercourse Distance (miles) Change in elevation along effective slope line {See Figure 3-4) (feet) Tc Hours Minutes • 1000 • 900 800 •500 \ \ -400 \ •240 •180 •600- • 300 -200 •100 120 -100 -90 -80 -70 ^4 \ \ \ \ \ Miles Feet _ 4000 \ - 3000 •50 •40 •30 20 •10 0.5- \ AE SOURCE: Califomia Division of Highways (1941) and Kirpich (1940) -2000 -1800 1600 — 1400 . 1200 -1000 •900 •800 700 — 600 •500 400 — 300 • 200 \ \ •SO •50 -40 — 30 — 20 -18 -16 -14 -12 -10 -9 •8 •7 -6 — 4 —3 Tc Nomograph for Determination of Time of Concentration (Tc) for Natural Watersheds HazMat/County Hydrogeology ManualAVatershed Nombgraph.FHS FIGURE Watershed Divide Watershed Divide Area "A" = Area "B" SOURCE: Califomia Division of Higiiways (1941) and Kirpicfi (1940) FIGURE Computation of Effective Slope for Natural Watersheds HazMat/County Hydrogeology Manual/Natural Walersheds SIope.FHS 500 EXAIVIPLE: Given: Watercourse Distance (D) = 250 Feet Slope (s) = 0.5% Runoff Coefficient (C) = 0.70 Overtand Flow Time (T) = 14.3 (Minutes SOURCE: Airport Drainage, Federal Aviation Administration, 1965 1.8 (1.1-C) VD" F I G U RE i Ratiohial Formula - Overland Time of Flow Nomograph HazMat/County Hydrogeology Manual/Overland Flow.FHS 2% Concrete Gutter RESIDENTIAL STREET ONE SIDE ONLY 2 3 4 5678. 9.10 Discharge (C.F.S.) EXAMPLE: Given: Q = 10 5 = 2.5% Chart gives: Depth = 0.4, Velocity = 4.4 f.p.s. SOURCE: San Diego County Department of Special District Seryices Design IVIanual 20 30 40 50 FIGURE Gutter and Roadway Discharge - Velocity Chart HazMat/County Hydrogeology Manual/Gutter Discharge_VeIocity.FH8 Orange County ) / /-'r-''^^—-a'—r'yr~^Al±lJi^da County / / --^^ .'"''/sAxm \ ( ^'^^:t V \ 'i I, \ \ s's X IVI e X 1 c County of San Diego Hydrology Manual Rain/all Isopluvials ICQ Year Rainfall Evern • fi Hn.ir.; '''V' Isopluvial (incties) MagJJotes. Stateplane Projeoloa Zones. NA083 Cfealion Dale: June 22,2001 MOTTO BE USED FOR DESIGN CALCUUTIONS amecP r Orange County ( ,''l2.bZ, \ -—; i 5.0 i -R I y e r s I do C o u n 1 SjiJlnbow Ij, \ Leucadia .Endnitas CaidirbylheSaa . Solana Beadi Oel Mar U Jolla i; iA' 1 ^-"->"\>>;^.i>:0!K^ i&4a*G/ / \ \ \ \ ^o ) \ 0ff — '-'/.\,.., U't.^\\\\\s:o., ( ~~^>-«:C2&tttoy/.b JVlJli,„ *'j-':''"'*=is< SanttlTcV'' i W^'Ov \ ..y«=^ ^""^ 5.0 •-' ('—CX;N, •'•''•, ^1 \ \ \ 7 ip-o/ ,~NM 8-0- ' .i) \ .' I ',5.5-, PaddcBesdi Mission Beadi Beadi I „ . 7r~i:^jen!ij-«s 7\^/J''' V'-^.. ""~'f->S5 \ \ \ V\\ \ ^ ./ i > \ \ \ Tlfuam WI e X • County of San Diego Hydrology Manual Rainfall Isopluvials 100 Year Rainfall Fvpnf, 0^ Hffiin -''V Isopluvial (inches) Map Notes Slateplane Projection. Zone6, NAD83 Creation Date: June 22,20O1 NOTTO BE USED FOR DESIGN CALCUUTIONS amecP 32°4S' 32*30' 33'30' 32*30' County of San Diego Hydrology Manual Soil Hydrologic Groups Legend Soil Groups ~] Group A I Group B "j Group C Group D Undetermined Data Unavailable DPW ^ «GK SanGIS THIS MAP IS PROVIDE[) WITHOUT WARRAJ^fTY W AMY KINO, ErTHER EKPRFSS OR nUKIED. INCLUDING, BUT NOT LIMTEO TO, THE niPLIED WAPRASTIES or MERCMAKTAariHY AND FITNESS FOR A PARTICULAR PURPOSE. Cop^ighl SanGIS All Righti RsMivn) Tha products may coribin Infonnabon frvn Itw SANDAO Regronal MomiM-gn Sysiem when unut b* iwoifuuij witfnul Vw wfrlMi pemuw e( SANOAa •mad hy Thomm B™*ei Mapj 3 Miles I October 24, 2005 1 Appendix C Detailed Hydraulic Calculations 10 PROJECT: 6" PVC @ 1% - FLOW ID B Diameter (inches) Slope (ft/ft) depth (ft) ... Velocity (fps) Area (Sq. Ft.) Critical Depth Critical Velocity PIPE FLOW 6 0.0100 0.23 2 . 75 0.09 0.25 2 .49 DATE TIME; Mannings n ... Q (cfs) depth/diameter Velocity head . Critical Slope Froude Number . .013 0.24 0.46 0.12 0.0077 1.16 PROJECT: 4" PVC @ 2% - FLOW ID C DATE: PIPE FLOW TIME: Diameter (inches) ... 4 Mannings n Slope (ft/ft) 0.0200 Q (cfs) depth (ft) 0.09 depth/diameter ... Velocity (fps) 2.21 Velocity head Area (Sq. Ft.) 0.02 Critical Depth o.ll Critical Slope ... Critical Velocity ... i.eo Froude Number .013 0.04 0.26 0.08 0.0081 1.57 PROJECT: 4" PVC Diameter (inches) Slope (ft/ft) depth (ft) ... Velocity (fps) Area (Sq. Ft.) Critical Depth Critical Velocity 9.2% PIPE BASIN OUTLET PIPE FLOW DATE: TIME: 4 0.0920 0.15 6.31 0.04 0.27 3.12 Mannings n Q (cfs) depth/diameter . . Velocity head ... Critical Slope .. Froude Number ... .013 0.24 0.45 0.62 0.0158 3.28 PROJECT: 4" PVC @ 2.5%MIN ( FUTURE OUTLET) DATE: PIPE FLOW TIME: Diameter (inches) ... 4 Mannings n .013 Slope (ft/ft) 0.0250 Q (cfs) 0.24 depth (ft) 0.23 depth/diameter ... 0.68 Velocity (fps) 3.83 Velocity head 0.23 Area (Sq. Ft.) 0.06 Critical Depth 0.27 Critical Slope ... 0.0158 Critical Velocity ... 3.12 Froude Number 1.51 I 1 October 24,2005 Appendix D Detention System Design 11 storm Discharge Volume 100-year-storm Duration C A (0.24 cfs) 1 Inflow Total Water In Basin (min) (cuft) (cu ft) (cu. ft) 1 0.63 0.170 14 18.60 120 105 2 0.63 0.170 29 11.89 153 124 3 0.63 0.170 43 9.16 177 133 4 0.63 0.170 58 7.61 196 138 5 063 0170 IZ S,59 212 140 6 0.63 0.170 86 5.86 226 139 7 0.63 0.170 101 5.30 238 138 8 0.63 0.170 115 4.86 250 135 9 0.63 0.170 130 4.51 261 131 10 0.63 0.170 144 4.21 271 127 11 0.63 0.170 158 3.96 280 122 12 0.63 0.170 173 3.74 289 116 13 0.63 0.170 187 3.56 297 110 14 0.63 0.170 202 3.39 305 103 15 0.63 0.170 216 3.24 313 97 16 0.63 0.170 230 3.11 320 89 17 0.63 0.170 245 2.99 327 82 18 0.63 0.170 259 2.88 333 74 19 0.63 0.170 274 2.78 340 66 20 0.63 0.170 288 2.69 346 58 25 0.63 0.170 360 2.33 375 15 30 0.63 0.170 432 2.07 400 -32 35 0.63 0.170 504 1.88 422 -82 40 0.63 0.170 576 1.72 443 -133 45 0.63 0.170 648 1.60 462 -186 50 0.63 0.170 720 1.49 479 -241 55 0.63 0.170 792 1.40 496 -296 60 0.63 0.170 864 0 1.33 511 -353 Detention Svstem The detention system is required in lieu of an exhaustive downstream analysis or upgrade to limit the 100-year maximum discharge to pre- construction rates. From the hydrology study, we get: Pre-Construction: Qioo(Z) = 0.28cfs Post-Constmction: Qioo(F=ABCD) = 0.71 cfs (the following design process was iterative, the results of the iterations are shown below): Propose one discharge pipe of 2.5" inside diameter. Because distance to exit is so short, orifice capacity equation should govem over all else: a = 0.034tf h = 200 -199.6 = 2.0' ft elevation head c = 0.62 (coefficient for square-off/standard cut pipe) Q = (0.62)(0.034)*SQRT[(2)(32.2)(2.0)] Q = 0.24cfs <=0.25 cfs allowed [ 0.28-(.016+0.16)] Determine maximimi storage capacity required for a 100-year-storm of any duration (see attached spreadsheet): Since the maximum demand occurs at less than a five-minute storm, and a five-minute-storm is the shortest-duration storm recognized by the County hydrology manual, the basin reqviires 140 ft^ of storage. Propose using a 24" diameter ADS pipe for storage 140 ft^/3.14 ft^ = 45 feet of pipe required. Emergency overflow is provided at the detention discharge basin in the event of unforeseen clog or greater than 100-year intensity storm. See plans for final design of system. October 24,2005 Appendix E Pump Design 12 Find Q for the Pump System Design Conditions: A=0.03 Ac ; C=0.95; 1=6.59 in/hr for Tc=5 min Q = CIA =0.19 cfs (also refer to flow charts appendix A- area Al) Pump needed: Duplex Pxmip System for 84 gpm Finding the head losses Velocity thought 4" discharge; V=Q/A = 0.19/ (u (0.1 (nf =2.16 I5)s V=2.161ps 1) . Depth, Z= 10'+4' =14' HL=13' 2) . Head Losses per Pipe; Length=86'; HL= 0.01 /ft (smooth pipe). HL=0.01x86=0.86' 3) .Head Losses per Fitting/ Valves; (4 elbows); HL=0.42(V^/2g ) HL= 4x 0.42(V^/2g)=4x.03=0.12' 4) . Head Losses per Valves/ Connections; (2); HL=1.8(V^/2g) HL=2xl .8(vV2g)=2x. 13=0.26' Total HL= 13'+0.86'+0.12'+0.26'=14.24' Total HL=15' P. 0. Box 791 • Poway, CA 92074 - (858) 748-8333 - Fax (858) 748-8412 ^CKI^MEMMMOR ^WCH ^^T5 ^^ER^^NDJ^' EOR BOTH PUMPS RUNNING TOGETHER, IS REQUIRED TO BE STORED AT ALL TIMES NEARBY THE DUPLEX SUMP PUMP DUPLEX CONTROL PANEL W/ ALTERNATING STARTER OPERATION MOUNTED OUTSIDE OE' SUMP IN LANDSCAPE AREA 60" 0 FIBERGLASS PREFABRICATED MANHOLE- DUPLEX HYDROMATIC PUMPS MODEL SKBOA? • SINGLE 0 POWER • • 2j0 V • 1,HP ^ 9 STAGGERED FLOATS 4" DISCHARGE LINE (EACH PUMP) 2' FLOW PROPERTIES: @ 100 YEAR STORM: 84 GAL/MIN/PUMP APPROX: 15 FT. TOTAL HEAD TO DETENTION BASIN PIPE CONTACT JAMES BUNCH @ BARRETT PUMPS i (619) 232-7867 8c REFERENCE: KOKOPELLI cr -60" 0- 16" MIN COVER TOP MANHOLE RIM ELEV. ± 195 -4" PVC FORCE MAIN (SCHEDULE 80) BTM SUMP ELEV. = 191 THIS IS NOT A COMPLETE COMPONENT AND INSTALLATION DETAIL - SEE COMPANION PUMP & SYSTEMS SPECS FOR MORE INFO. DETAIL 'A' SUMP WITH DUPLEX PUMP SYSTEM NO SCALE ~ ~ '