Loading...
HomeMy WebLinkAboutCT 01-06; CALAVERA HILLS VILLAGE X; HYDROLOGY STUDY CALAVERA HILLS VILL X; 2002-09-130^ /C'^/r/^ HANSEN PAT£ Hy'O/eoijar^y sru^r /^xf cn^co-oz THAT ^cx^/e_5 V/UA6-E X 5^ acm&^T H4 hi San Diego County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software, (c) 1993 Version 3.2 Rational method hydrology program based on San Diego County Flood Control Division 1985 hydrology manual Rational Hydrology Study Date: 02/07/01 VILLAGE X T.M. HYDROLOGY STUDY SYSTEM 100 & 200 JAN. 25, 2001 J.N. 98-1020 BY: CSO ********* Hydrology Study Control Information ************ O'Day Consultants, San Diego, California - S/N 10125 Rational hydrology study storm event year is 100.0 Map data precipitation entered: 6 hour, precipitation(inches) = 2.600 24 hour precipitation(inches) = 4.300 Adjusted 6 hour precipitation (inches) = 2.600 P6/P24 = 60.5% San Diego hydrology manual 'C' values used Runoff coefficients by rational method Process from Point/Station 102.000 to Point/Station 104.000 **** INITIAL AREA EVALUATION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Initial subarea flow distance = 110.00(Ft.) Highest elevation = 265.80(Ft.) Lowest elevation = 262.10(Ft.) Elevation difference = 3.70(Ft.) Time of concentration calculated by the urban areas overland flow method (App X-C) = 6.93 min. TC = [1 . 8* (1. 1-C) *distance" . 5) / (% slope'^ (1/3) ] TC = [1.8*(1.1-0.5500)*(110.OC^.5)/( 3.36"(1/3) ]= 6.93 Rainfall intensity (I) = 5.550 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.153(CFS) Total initial stream area = 0.050(Ac.) Process from Point/Station 104.000 to Point/Station 104.000 **** SUBAREA FLOW ADDITION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 6.93 min. Rainfall intensity = 5.550 (In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 0.153(CFS) for 0.050(Ac.) Total runoff = 0.305(CFS) Total area = 0.10(Ac.) Process from Point/Station 104.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 106.000 Upstream point/station elevation = 261.10(Ft.) Downstream point/station elevation = 260.80(Ft.) Pipe length = 30. 00 (Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 0.305 (CFS) Nearest computed pipe diameter = 6.00(In.) Calculated individual pipe flow = 0.305(CFS) Normal flow depth in pipe = 2.86(In.) Flow top width inside pipe = 5.99(In.) Critical Depth = 3.35(In.) Pipe flow velocity = 3.31(Ft/s) Travel time through pipe = 0.15 min. Time of concentration (TC) = 7.08 rain. Process from Point/Station 103.000 **** SUBAREA FLOW ADDITION **** to Point/Station 106.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type Time of concentration = Rainfall intensity = 5. 7.08 min. .473(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = Subarea runoff = 0.181{CFS) for 0.060(Ac.) Total runoff = 0.486(CFS) Total area = 0.16(Ac.) 0 . 550 Process from Point/Station 106.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 108.000 Upstream point/station elevation = 260.80(Ft.) Downstream point/station elevation = 260.40(Ft.) Pipe length = 43.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 0.486(CFS) Nearest computed pipe diameter = 6, Calculated individual pipe flow = 0, Normal flow depth in pipe = 3, 91(In,) 00 (In . ) 486(CFS) Flow top width inside pipe = 5.71(In.) Critical Depth = 4.26(In.) Pipe flow velocity = 3.58(Ft/s) Travel time through pipe = 0.20 min. Time of concentration (TC) = 7.28 min. Process from Point/Station 108.000 to Point/Station **** CONFLUENCE OF MAIN STREAMS **** 108.000 The following data inside Main Stream is listed: In Main Stream number: 1 Stream flow area = 0.160(Ac.) Runoff from this stream = 0.486(CFS) Time of concentration = 7.28 rain. Rainfall intensity = 5.376(In/Hr) Program is now starting with Main Stream No. 2 Process from Point/Station 202.000 to Point/Station **** INITIAL AREA EVALUATION **** 204.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type Initial subarea flow distance = Highest elevation = 272.70(Ft.) Lowest elevation = 271.35(Ft.) Elevation difference = 1.35(Ft. Time of concentration calculated by the urban areas overland flow method (App X-C) = 11.50 min. TC = [1.8*(l.l-C)*distance".5)/(% slope-(l/3)] TC = [1. 8* (1 . 1-0.5500) * (135. OO'^ . 5) / ( 1.00^(1/3)]= 11.50 Rainfall intensity (I) = 4.002 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.352(CFS) Total initial stream area = 0.160(Ac.) 135.00(Ft.) ) Process from Point/Station 204.000 to Point/Station **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 205.000 Top of street segment elevation = 271.350(Ft.) End of street segment elevation = 264.950(Ft.) Length of street segment = 350.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000{Ft.) Distance from crown to crossfall grade break = 18.500(Ft, Slope frora gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) 0. 020 0.0150 0.0150 0.925(CFS) 2.195(Ft/s) 14.16 min. Slope from curb to property line (v/hz) = Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = Manning's N from grade break to crown Estimated mean flow rate at midpoint of street = Depth of flow = 0.202(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 3.288(Ft.) Flow velocity = 2.19(Ft/s) Travel time = 2.66 min. TC = Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type Rainfall intensity = 3.500 (In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 1.001(CFS) for 0.520(Ac.) Total runoff = 1.353(CFS) Total area = 0.68(Ac.) Street flow at end of street = 1.353(CFS) Half street flow at end of street = 0.677(CFS) Depth of flow = 0.226(Ft.), Average velocity = 2.253(Ft/s) Flow width (from curb towards crown)= 4.448(Ft.) ] Process from Point/Station **** SUBAREA FLOW ADDITION 206.000 to Point/Station 206.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 14.16 min. Rainfall intensity = 3.500(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area, Rational method,Q=KCIA, C Subarea runoff = 1.675(CFS) for 0.870(Ac.) Total runoff = 3.028(CFS) Total area = 1.55(Ac 0 . 550 Process from Point/Station 206.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 108.000 Upstream point/station elevation = 263.00(Ft.) Downstream point/station elevation = 260.40(Ft.) Pipe length = 80.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = Nearest computed pipe diameter = 9 Calculated individual pipe flow = 3 Normal flow depth in pipe = 6.43(In.) Flow top width inside pipe = 8.13(In. Critical depth could not be calculated. 3.028(CFS) 00(In.) 028(CFS) Pipe flow velocity = 8.97(Ft/s) Travel time through pipe = 0.15 min. Time of concentration (TC) = 14.31 min. Process from Point/Station 108.000 to Point/Station **** CONFLUENCE OF MAIN STREAMS **** 108.000 The following data inside Main Streara is listed: In Main Stream number: 2 Stream flow area = 1.550(Ac.) Runoff from this stream = 3.028(CFS) Time of concentration = 14.31 min. Rainfall intensity = 3.477(In/Hr) Summary of stream data: St ream No. Flow rate (CFS) TC (min) Rainfall Intensity (In/Hr) 1 2 Qmax(l) = Qmax (2) 0.486 3.028 000 000 0.647 * 1.000 * 7 . 28 14 .31 1.000 * 0 . 509 * 1.000 * 1.000 * 0.486) 3.028) 5.376 3. 477 -t- + = 0.486) + 3.028) + 2 . 027 3 . 342 Total of 2 main streams to confluence: Flow rates before confluence point: 0.486 3.028 Maximum flow rates at confluence using above data: 2.027 3.342 Area of streams before confluence: 0.160 1.550 Results of confluence: Total flow rate = 3.342(CFS) Time of concentration = 14.309 rain. Effective stream area after confluence = 1.710(Ac.) Process from Point/Station 108.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 110.000 Upstream point/station elevation = 260.40(Ft.) Downstream point/station elevation = 217.10(Ft.) Pipe length = 590.00(Ft.) Manning's N = 0,011 No. of pipes = 1 Required pipe flow = 3.342(CFS) Nearest coraputed pipe diameter = 9.00(In.) Calculated individual pipe flow = 3. 342(CFS) Normal flow depth in pipe = 5.19(In.) Flow top width inside pipe = 8.89{In.) Critical depth could not be calculated. Pipe flow velocity = 12.68(Ft/s) Travel time through pipe = 0.78 min. Time of concentration (TC) = 15.08 rain. Process from Point/Station 110.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 112.000 Upstream point/station elevation = 217.10(Ft.) Downstream point/station elevation = 215.40(Ft.) Pipe length = 75.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 3.342(CFS) Nearest computed pipe diameter = 12.00 (In.) Calculated individual pipe flow = 3.342(CFS) Normal flow depth in pipe = 6. 19 (In.) Flow top width inside pipe = 11. 99 (In.) Critical Depth = 9.38(In.) Pipe flow velocity = 8.18(Ft/s) Travel time through pipe = 0.15 min. Time of concentration (TC) = 15.24 min. Process from Point/Station 108.000 to Point/Station **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 112.000 Top of street segment elevation = 262.200(Ft.) End of street segment elevation = 217.300(Ft.) Length of street segment = 590.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000 (Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000 (Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at raidpoint of street = Depth of flow = 0.252(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 5.753(Ft.) Flow velocity = 4.92(Ft/s) Travel time = 2.00 min. TC = 17.24 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 3.083(In/Hr) for a 100.0 year storm 4.261(CFS) 4.915(Ft/s) 2.65(Ac.) Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 1.594(CFS) for 0.940(Ac.) Total runoff = 4.936(CFS) Total area = Street flow at end of street = 4.936(CFS) Half street flow at end of street = 2.468(CFS) Depth of flow = 0.261(Ft.), Average velocity = 5.050(Ft/s) Flow width (from curb towards crown)= 6.215(Ft.) Process from Point/Station **** SUBAREA FLOW ADDITION **** 112.000 to Point/Station 112.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 17.24 min. Rainfall intensity = 3.083(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 3.069(CFS) for 1.810(Ac.) Total runoff = 8.006(CFS) Total area = 4.46(Ac.) Process from Point/Station **** SUBAREA FLOW ADDITION 112.000 to Point/Station 112 . 000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 17.24 min. Rainfall intensity = 3.0B3(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 2.645(CFS) for l,560(Ac.) Total runoff = 10.651(CFS) Total area = 6.02(Ac.) Process frora Point/Station 112.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 114.000 Upstream point/station elevation = 215.40(Ft.) Downstream point/station elevation = 214.45(Ft.) Pipe length = 95.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 10. 651 (CFS) Nearest computed pipe diameter = 18.00(In.) Calculated individual pipe flow = 10.651(CFS) Norraal flow depth in pipe = 12.84(In.) Flow top width inside pipe = 16,28(In.) Critical Depth = 15,03(In,) Pipe flow velocity = 7.90(Ft/s) Travel time through pipe = 0.20 min. Time of concentration (TC) = 17.44 min. Process from Point/Station 114.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 116.000 Upstreara point/station elevation = 214.45(Ft.) Downstream point/station elevation = 175.00(Ft.) Pipe length = 90.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 10.651(CFS) Nearest computed pipe diameter = 9.00(In.) Calculated individual pipe flow = 10.651(CFS) Normal flow depth in pipe = 6.22(In.) Flow top width inside pipe = 8.32(In.) Critical depth could not be calculated. Pipe flow velocity = 32.71(Ft/s) Travel time through pipe = 0.05 min. Time of concentration (TC) = 17.48 min. End of computations, total study area = 6.02 (Ac.) 5^ e^i^rr H 4 M San Diego County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software, (c) 1993 Version 3.2 Rational method hydrology program based on San Diego County Flood Control Division 1985 hydrology raanual Rational Hydrology Study Date: 02/06/01 VILLAGE X T.M. HYDROLOGY STUDY SYSTEM 4 00 JAN. 25, 2001 J.N. 98-1020 BY: CSO FILE: VLX400 Hydrology Study Control Information ***-*-*** + *-^ O'Day Consultants, San Diego, California - S/N 10125 Rational hydrology study storm event year is 100.0 Map data precipitation entered: 6 hour, precipitation(inches) = 2.600 24 hour precipitation(inches) = 4.300 Adjusted 6 hour precipitation (inches) = 2.600 P6/P24 = 60.5% San Diego hydrology manual 'C values used Runoff coefficients by rational method Process from Point/Station 402.000 to Point/Station 404.000 **** INITIAL AREA EVALUATION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Initial subarea flow distance = 100.00(Ft.) Highest elevation = 272.70(Ft.) Lowest elevation = 271.70(Ft.) Elevation difference = 1.00(Ft.) Time of concentration calculated by the urban areas overland flow method (App X-C) = 9.90 min. TC = [1.8*(l.l-C)*distance'^.5)/(% slope'^ (1/3) ] TC = [1. 8* (1. 1-0. 5500) * (100, OO'-.S) / ( 1.00^(1/3)]= 9.90 Rainfall intensity (I) = 4.409 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.461(CFS) Total initial stream area = 0.190(Ac.) Process from Point/Station 404.000 to Point/Station 406.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 271.350(Ft.) End of street segment elevation = 257.600(Ft.) Length of street segment = 275.000(Ft.) Height of curb above gutter flowline = 6.0 (In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope frora gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike frora flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = 0.934(CFS) Depth of flow = 0.155(Ft.), Average velocity = 4.316(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 1.500(Ft.) Flow velocity = 4.32(Ft/s) Travel time = 1.06 min. TC = 10.96 min. Adding area flow to street Deciraal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Deciraal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 4.129(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C = 0.550 Subarea runoff = 0.886(CFS) for 0.390(Ac.) Total runoff = 1.346(CFS) Total area = 0.58(Ac.) Street flow at end of street = 1.346(CFS) Half street flow at end of street = 0.673(CFS) Depth of flow = 0.194(Ft.), Average velocity = 3,666(Ft/s) Flow width (from curb towards crown)= 2.849(Ft.) - + Process from Point/Station 406.000 to Point/Station 406.000 **** SUBAREA FLOW ADDITION **** Decimal fraction soil group A = 0.000 Deciraal fraction soil group B = 0.000 Deciraal fraction soil group C = 0.000 Deciraal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 10.96 rain. Rainfall intensity = 4.129(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area, Rational method, Q=KCIA, C = 0.550 Subarea runoff = 2.816(CFS) for l,240(Ac.) Total runoff = 4.162(CFS) Total area = 1.82(Ac.) Process from Point/Station 406,000 to Point/Station 406.000 **** SUBAREA FLOW ADDITION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Deciraal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 10.96 min. Rainfall intensity = 4.129(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area, Rational method,Q=KCIA, C = 0.550 Subarea runoff = 0.659(CFS) for 0.290(Ac.) Total runoff = 4.821(CFS) Total area = 2.11(Ac.) End of computations, total study area = 2.11 (Ac.) San Diego County Rational Hydrology Program CIVILCADD/CIVILDESIGN Engineering Software, (c) 1993 Version 3.2 Rational method hydrology program based on San Diego County Flood Control Division 1985 hydrology manual Rational Hydrology Study Date: 03/16/01 VILLAGE X T.M. HYDROLOGY STUDY SYSTEM 500, 600, 700, & 900 MARCH 16, 2001 J.N. 98-1020 BY: CSO FILE: VLX500 Hydrology Study Control Information ***-*-*-»r***-* O'Day Consultants, San Deigo, California - S/N 10125 Rational hydrology study storm event year is 100.0 Map data precipitation entered: 6 hour, precipitation(inches) = 2.600 24 hour precipitation(inches) = 4.300 Adjusted 6 hour precipitation (inches) = 2.600 P6/P24 = 60.5% San Diego hydrology manual 'C values used Runoff coefficients by rational method Process from Point/Station 502,000 to Point/Station 504.000 **** INITIAL AREA EVALUATION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Deciraal fraction soil group C = 0.000 Decimal fraction soil group D = 1,000 [SINGLE FAMILY area type ] Initial subarea flow distance = 110.00(Ft.) Highest elevation = 221,50(Ft,) Lowest elevation = 212.00(Ft,) Elevation difference = 9.50(Ft.) Time of concentration calculated by the urban areas overland flow method (App X-C) = 5.06 rain. TC = [1. 8* (1 . 1-C) *distance'" . 5) / (% slope"(l/3)] TC = [1. 8* (1 . 1-0 .5500) * (110.00'^. 5) / ( 8.64^(1/3)]= 5.06 Rainfall intensity (I) = 6.797 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.299(CFS) Total initial stream area = 0.080(Ac.) Process from Point/Station 504.000 to Point/Station 506.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 6.0(In.) 20.000(Ft.) break = 18.500(Ft.) 2.000(In.) , 0130 grade break = Top of street segraent elevation = 212.000(Ft.) End of street segraent elevation = 209.600(Ft.) Length of street segment = 235.000(Ft.) Height of curb above gutter flowline Width of half street (curb to crown) Distance from crown to crossfall grade Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = Manning's N in gutter = 0 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.145(Ft.), Average velocity = Streetflow hydraulics at raidpoint of street travel Halfstreet flow width = 1.500(Ft.) Flow velocity = 1.87(Ft/s) Travel time = 2.10 rain. Adding area flow to street Decimal fraction soil group A Decimal fraction soil group B Decimal fraction soil group C Decimal fraction soil group D [SINGLE FAMILY area type Rainfall intensity = 5 Runoff coefficient used for Subarea runoff = 1.136(CFS) Total runoff = 1.435(CFS) Street flow Half street 0.356(CFS) 1.869(Ft/s) TC = = 0.000 = 0.000 = 0.000 = 1.000 7.16 min. 436(In/Hr) for a 100.0 year storm sub-area. Rational method,Q=KCIA, C = 0.550 for 0.380(Ac.) Total area = 0.46(Ac.) at end of street = 1.435(CFS) flow at end of street = 0.718(CFS) Depth of flow = 0.247(Ft.), Average velocity = 1.774(Ft/s) Flow width (from curb towards crown)= 5.495(Ft.) Process from Point/Station **** SUBAREA FLOW ADDITION 506.000 to Point/Station 506.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 7.16 min. Rainfall intensity = 5.436(In/Hr) for a 100.0 year storra Runoff coefficient used for sub-area, Rational method,Q=KCIA, C = 0.550 Subarea runoff = 1.794(CFS) for 0.600(Ac.) Total runoff = 3.229(CFS) Total area = 1.06(Ac.) 4- + + + J Process from Point/Station 506.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 508 . 000 Upstream point/station elevation = 200.60(Ft.) Downstream point/station elevation = 199.50(Ft.) Pipe length = 45.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 3.229(CFS) Nearest computed pipe diameter = 12.00(In.) Calculated individual pipe flow = 3.229(CFS) Normal flow depth in pipe = 5.93(In.) Flow top width inside pipe = 12.00(In.) Critical Depth = 9.23(In.) Pipe flow velocity = 8.34(Ft/s) Travel time through pipe = 0.09 rain. Time of concentration (TC) = 7.25 min. Process from Point/Station 508.000 to Point/Station 508.000 **** CONFLUENCE OF MAIN STREAMS **** The following data inside Main Stream is listed: In Main Stream nuraber: 1 Stream flow area = 1.060(Ac.) Runoff from this stream = 3.229(CFS) Time of concentration = 7.25 min. Rainfall intensity = 5.392(In/Hr) Program is now starting with Main Streara No. 2 Process from Point/Station 602.000 to Point/Station 604.000 **** INITIAL AREA EVALUATION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Initial subarea flow distance = 100.00(Ft.) Highest elevation = 239.70(Ft.) Lowest elevation = 238.20(Ft.) Elevation difference = 1.50(Ft.) Time of concentration calculated by the urban areas overland flow method (App X-C) = 8.65 min. TC = [1.8*(1.1-C)*distance".5)/(% slope"(l/3)] TC = [1. 8* (1 . 1-0. 5500) * (100 . 00'^ . 5) / ( 1. 50'^ (1/3 ) ] = 8.65 Rainfall intensity (I) = 4.811 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.476(CFS) Total initial stream area = 0.180(Ac.) Process frora Point/Station 604.000 to Point/Station 606.000 ••*** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 238.200(Ft. End of street segment elevation = 211.200(Ft. 775.000(Ft. flowline = ) 6.0(In.) Length of street segment = Height of curb above gutter Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.223(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 4.337(Ft.) Flow velocity = 3.10(Ft/s) Travel time = 4.17 min 1.799(CFS) 095(Ft/s) Adding area flow to street Deciraal fraction soil group A Deciraal fraction soil group B Decimal fraction soil group C Decimal fraction soil group D [SINGLE FAMILY area type Rainfall intensity = 3 TC = = 0.000 = 0.000 = 0.000 = 1.000 12.82 min. 732(In/Hr) for a 100.0 year storm used for sub-area, Rational method,Q=KCIA, C 2.053(CFS) for 1.000(Ac.) 2.529(CFS) Total area = of street = 2.529(CFS) 1.264(CFS) 1.18(Ac.) Runoff coefficient Subarea runoff = Total runoff = Street flow at end Half street flow at end of street 0.244(Ft.), Average velocity = 3.251(Ft/s) = 0.550 Depth of flow = Flow width (from curb towards crown)^ 5.352(Ft.) Process from Point/Station **** SUBAREA FLOW ADDITION 606.000 to Point/Station 606.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type Time of concentration = 12.82 min. Rainfall intensity = 3.732(In/Hr) Runoff coefficient used for sub-area, Subarea runoff = 4. 516(CFS) for for a 100.0 year storm Rational method, Q=KCIA, C 2.200(Ac.) 0 . 550 Total runoff 7.044(CFS) Total area 3.38(Ac.) Process from Point/Station 606.000 to Point/Station **** SUBAREA FLOW ADDITION **** 606.000 Decimal fraction soil group A 0 . 000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 12.82 min. Rainfall intensity = 3.732(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C = 0.550 Subarea runoff = 2.525(CFS) for 1.230(Ac.) Total runoff = 9.569(CFS) Total area = 4 . 61(Ac.) Process from Point/Station 606.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 201.20(Ft.) Downstream point/station elevation = 199.50(Ft.) Pipe length = 85.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 9.569 (CFS) Nearest computed pipe diameter = 15.00(In.) Calculated individual pipe flow = 9. 569(CFS) Normal flow depth in pipe = 10.99(In.) Flow top width inside pipe = 13.27(In.) Critical Depth = 14.07(In.) Pipe flow velocity = 9.94(Ft/s) Travel time through pipe = 0.14 min. Time of concentration (TC) = 12.96 min. 508.000 Process from Point/Station 508.000 to Point/Station **** CONFLUENCE OF MAIN STREAMS **** 508.000 The following data inside Main Stream is listed: In Main Stream number: 2 Streara flow area = 4.610(Ac.) Runoff from this stream = 9.569(CFS) Time of concentration = 12.96 min. Rainfall intensity = 3.705(In/Hr) Summary of stream data: Stream No . Flow rate (CFS ) TC (min) Rainfall Intensity (In/Hr) 1 2 Qmax(1) 3 . 9. 1 . 1 . Qmax(2) = 229 569 000 000 0 . 687 1 . 000 7 . 25 12 , 96 1 . 000 0. 559 1 . 000 1. 000 5 . 392 3,705 3.229) + 9.569) + 3.229) + 9.569) + 8 . 578 11.788 Total of 2 main streams to confluence: Flow rates before confluence point: 3.229 9.569 Maximura flow rates at confluence using above data: 8.578 11.788 Area of strearas before confluence: 1.060 4.610 Results of confluence: Total flow rate = 11.788(CFS) Tirae of concentration = 12.964 rain. Effective stream area after confluence = 5.670(Ac.) Process from Point/Station 508.000 to Point/Station 510.000 PIPEFLOW TFLAVEL TIME (Program estimated size) **** Upstream point/station elevation = 199.50(Ft.) Downstream point/station elevation = 198.95(Ft.) Pipe length = 225.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 11.788(CFS) Nearest computed pipe diameter = 24.00 (In.) Calculated individual pipe flow = 11.788(CFS) Normal flow depth in pipe = 17.67(In.) Flow top width inside pipe = 21.15{In.) Critical Depth = 14.79(In.) Pipe flow velocity = 4.76(Ft/s) Travel time through pipe = 0.7 9 min. Time of concentration (TC) = 13.75 min. Process frora Point/Station 510.000 to Point/Station 510.000 **** CONFLUENCE OF MINOR STREAMS **** Along Main Stream number: 1 in normal stream number 1 Streara flow area = 5.670(Ac.) Runoff from this streara = 11.788(CFS) Time of concentration = 13.75 min. Rainfall intensity = 3.567(In/Hr) Process from Point/Station 702.000 to Point/Station 704.000 **** INITIAL AREA EVALUATION **** Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0,000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1,000 [SINGLE FAMILY area type ] Initial subarea flow distance = 100.00(Ft.) Highest elevation = 228.30(Ft.) Lowest elevation = 223.30(Ft.) Elevation difference = 5.00(Ft.) Time of concentration calculated by the urban areas overland flow method (App X-C) = 5.79 min. TC = [1.8*(1.1-C)*distance".5)/(% slope"(l/3)) TC = [1. 8* (1. 1-0.5500) * (100. 00" . 5) / ( 5 . 00'^ (1/3) ] = 5.79 Rainfall intensity (I) = 6.232 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.651(CFS) Total initial streara area = 0.190(Ac.) Process from Point/Station 704.000 to Point/Station 706.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 211. 300(Ft.) End of street segment elevation = 206.700(Ft.) Length of street segment = 200.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance frora crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000{In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated raean flow rate at midpoint of street = 1.080(CFS) Depth of flow = 0.205(Ft.), Average velocity = 2.461(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 3.418(Ft.) Flow velocity = 2.46(Ft/s) Travel time = 1.35 min. TC = 7.14 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 5.442(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area, Rational method, Q=KCIA, C = 0.550 Subarea runoff = 0.748(CFS) for 0.250(Ac,) Total runoff = 1.400 (CFS) Total area = 0.44 (Ac) Street flow at end of street = 1.400(CFS) Half street flow at end of street = 0.700(CFS) Depth of flow = 0.221(Ft.), Average velocity = 2.503(Ft/s) Flow width (from curb towards crown)= 4.208(Ft.) Process from Point/Station 706.000 to Point/Station 706,000 **** SUBAREA FLOW ADDITION **** Decimal fraction soil group A = 0,000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0,000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 7.14 min. Rainfall intensity = 5.442 (In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = Subarea runoff = 3.233(CFS) for 1.080(Ac.) Total runoff = 4. 632(CFS) Total area = 1.52(Ac.) 0 . 550 Process from Point/Station 706.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estiraated size) **** 510.000 Upstream point/station elevation = 199.76(Ft.) Downstream point/station elevation = 198.95(Ft.) Pipe length = 40.63(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 4.632(CFS) Nearest computed pipe diameter = 12.00(In.) Calculated individual pipe flow = 4.632(CFS) Normal flow depth in pipe = 7.97(In.) Flow top width inside pipe = 11.34(In.) Critical Depth = 10.74(In.) Pipe flow velocity = 8.37(Ft/s) Travel time through pipe = 0.08 min. Time of concentration (TC) = 7.22 min. Process from Point/Station 510.000 to Point/Station **** CONFLUENCE OF MINOR STREAMS **** 510.000 Along Main Stream number: 1 in normal stream number 2 Streara flow area = 1.520(Ac.) Runoff frora this stream = 4.632(CFS) Time of concentration = 7.22 min. Rainfall intensity = 5.403(In/Hr) Summary of stream data: Stream No . Flow rate (CFS) TC (min) Rainfall Intensity (In/Hr) 1 2 Qmax(1) Qmax(2) 11. 788 4 . 632 1. 000 0. 660 1 . 000 1 , 000 13.75 7 . 22 1 . 000 1 . 000 0 . 525 1 . 000 3.567 5. 403 11.788) 4- 4.632) 4- 11.788) + 4.632) + 14,846 10,825 Total of 2 streams to confluence: Flow rates before confluence point: 11.788 4,632 Maximum flow rates at confluence using above data: 14.846 10.825 Area of streams before confluence: 5.670 1.520 Results of confluence: Total flow rate = 14.846(CFS) Time of concentration = 13.752 min. Effective stream area after confluence = 7.190(Ac.) Process from Point/Station 510.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 512.000 Upstream point/station elevation = 198.95(Ft.) Downstream point/station elevation = 187.75(Ft.) Pipe length = 280.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 14.846(CFS) Nearest computed pipe diameter = 15.00(In.) Calculated individual pipe flow = 14.846(CFS) Normal flow depth in pipe = 11. 93 (In.) Flow top width inside pipe = 12.10(In.) Critical depth could not be calculated. Pipe flow velocity = 14. 18(Ft/s) Travel time through pipe = 0.33 min. Time of concentration (TC) = 14.08 min. + 4- Process from Point/Station 512.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 187.75(Ft.) Downstream point/station elevation = 187.45(Ft.) Pipe length = 30.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 14.846(CFS) Nearest computed pipe diameter = 21.00(In.) Calculated individual pipe flow = 14.846 (CFS) Normal flow depth in pipe = 14.11 (In.) Flow top width inside pipe = 19.72(In.) Critical Depth = 17.14(In.) Pipe flow velocity = 8.63(Ft/s) Travel time through pipe = 0.06 rain. Time of concentration (TC) = 14.14 min. 514.000 Process from Point/Station 506.000 to Point/Station **** STREET FLOW TRAVEL TIME 4- SUBAREA FLOW ADDITION **** 511.000 209.500(Ft.) 206.800(Ft.) 280.000(Ft.) Top of street segment elevation End of street segment elevation = Length of street segment = 280.uvju\ri Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft,) stance from crown to crossfall grade break = 18,500(Ft )pe from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz] Dis uii.cdncjfc; 11 um cjiuwn LO crussidii graue Ore Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutt er hike frcm flowline = 2.000 (In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at raidpoint of street = 15.393(CFS) Depth of flow = 0.453{Ft.), Average velocity = 2.962(Ft/s) Streetflow hydraulics at raidpoint of street travel: Halfstreet flow width = 15.799(Ft.) Flow velocity = 2.96(Ft/s) Travel time = 1.58 min. TC = 15.71 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 3.273(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 0.954(CFS) for 0.530(Ac.) Total runoff = 15.800(CFS) Total area = 7.72(Ac.) Street flow at end of street = 15.800(CFS) Half street flow at end of street = 7.900(CFS) Depth of flow = 0.456(Ft.), Average velocity = 2. 980(Ft/s) Flow width (from curb towards crown)= 15.963(Ft.) Process frora Point/Station 511.000 to Point/Station 514.000 **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** Top of street segment elevation = 206.800(Ft.) End of street segment elevation = 196.500(Ft.) Length of street segment = 300.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10. 000 (Ft.) Siope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N from gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estiraated mean flow rate at midpoint of street = 16.230 (CFS) Depth of flow = 0.389(Ft.), Average velocity = 4.799(Ft/s) Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 12.603(Ft.) Flow velocity = 4.80(Ft/s) Travel time = 1.04 min. TC = 16.76 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 3.140(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C = 0.550 Subarea runoff = 0.725(CFS) for 0.420(Ac.) Total runoff = 16.525(CFS) Total area = 8.14(Ac.) Street flow at end of street = 16. 525 (CFS) Half street flow at end of street = 8.263(CFS) Depth of flow = 0.391(Ft.), Average velocity = 4.820(Ft/s) Flow width (frora curb towards crown)= 12.696(Ft.) Process from Point/Station **** SUBAREA FLOW ADDITION 514.000 to Point/Station 514 . 000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 16.76 min. Rainfall intensity = 3.140(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C = Subarea runoff = 5.060(CFS) for 2.930(Ac.) Total runoff = 21.586(CFS) Total area = 11.07(Ac.) 0.550 Process from Point/Station 514.000 to Point/Station 516.000 **** PIPEFLOW TRAVEL TIME (Program estimated size) **** Upstream point/station elevation = 187. 45(Ft.) Downstream point/station elevation = 185.00(Ft.) Pipe length = 122.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 21.586(CFS) Nearest computed pipe diameter = 21.00(In.) Calculated individual pipe flow = 21. 586(CFS) Normal flow depth in pipe = 14. 39(In.) Flow top width inside pipe = 19.51(In.) Critical Depth = 19.57(In.) Pipe flow velocity = 12.30(Ft/s) Travel time through pipe = 0.17 min. Time of concentration (TC) = 16.92 min. Process from Point/Station **** CONFLUENCE OF MAIN STREAMS 516.000 to Point/Station + • + 516.000 The following data inside Main Stream is listed: In Main Stream number: 1 Stream flow area = 11.070(Ac.) Runoff from this stream = 21.586(CFS) Time of concentration = 16,92 min. Rainfall intensity = 3,120(In/Hr) Program is now starting with Main Stream No. 2 Process from Point/Station **** INITIAL AREA EVALUATION 902.000 to Point/Station 904.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Initial subarea flow distance = 80.00(Ft.) Highest elevation = 270.30(Ft.) Lowest elevation = 269.40(Ft.) Elevation difference = 0.90(Ft.) Tirae of concentration calculated by the urban areas overland flow method (App X-C) = 8.51 min. TC = [1. 8* (1.1-C) *distance" . 5) / (% slope'^ (1/3) ] TC = [1. 8* (1.1-0.5500) * ( 80.00'^.5)/( 1.13'^ (1/3) ] = 8.51 Rainfall intensity (I) = 4.860 for a 100.0 year storm Effective runoff coefficient used for area (Q=KCIA) is C = 0.550 Subarea runoff = 0.347(CFS) Total initial streara area = 0.130(Ac.) Process from Point/Station 904.000 to Point/Station **** STREET FLOW TRAVEL TIME 4- SUBAREA FLOW ADDITION **** 906.000 Top of street segment elevation = 269.400(Ft.) End of street segment elevation = 242.800(Ft.) Length of street segment = 240.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18 Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance from curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N frora gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estiraated mean flow rate at midpoint of street = Depth of flow = 0.142(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 1.500(Ft.) Flow velocity = 6.05(Ft/s) Travel t ime — 0.66min. TC= 9.17 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] ,500(Ft.) 1.096(CFS) 6.055(Ft/s) Rainfall intensity = 4.631(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C = 0.550 Subarea runoff = 1.426(CFS) for 0.560(Ac.) Total runoff = 1.774 (CFS) Total area = 0.69(Ac.) Street flow at end of street = 1.774(CFS) Half street flow at end of street = 0.887(CFS) Depth of flow = 0.183(Ft.), Average velocity = 5.678(Ft/s) Flow width (from curb towards crown)= 2.317(Ft.) Process from Point/Station **** SUBAREA FLOW ADDITION 906.000 to Point/Station 906.000 Deciraal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Tirae of concentration = 9.17 min. Rainfall intensity = 4.631(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 0.891(CFS) for 0.350(Ac.) Total runoff = 2.665(CFS) Total area = 1.04(Ac.) Process from Point/Station 906.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estiraated size) **** Upstream point/station elevation = Downstreara point/station elevation = Pipe length = 350.00(Ft.) Manning's No. of pipes = 1 Required pipe flow = Nearest computed pipe diaraeter = Calculated individual pipe flow Normal flow depth in pipe = 4.39(In.) Flow top width inside pipe = 9.00(In. Critical Depth = 8.44(In,) Pipe flow velocity = 12.47(Ft/s) Travel time through pipe = 0.47 min. Time of concentration (TC) = 9.64 rain 910.000 236.40(Ft.) 208.00(Ft.) N = 0.011 2.665(CFS) 00(In.) 665(CFS) 9. 2. ) Process from Point/Station 906.000 to Point/Station **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 910.000 Top of street segment elevation = 242.800(Ft.) End of street segment elevation = 215.500(Ft.) Length of street segment = 350.000(Ft.) Height of curb above gutter flowline = 6.0 (In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street 10.000(Ft. 0.020 0. 0150 0.0150 3.255(CFS) 4.750(Ft/s) Distance from curb to property line = Slope from curb to property line (v/hz) = Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N frora gutter to grade break = Manning's N from grade break to crown = Estimated mean flow rate at midpoint of street = Depth of flow = 0.235(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 4.900(Ft.) Flow velocity = 4.75(Ft/s) Travel time = 1.23 min. TC = 10.87 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 4.151(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C = 0.550 Subarea runoff = 1.050(CFS) for 0.460(Ac.) Total runoff = 3.716(CFS) Total area = Street flow at end of street = 3.716(CFS) Half street flow at end of street = 1.858 (CFS) Depth of flow = 0.243(Ft.), Average velocity = 4 Flow width (from curb towards crown)= 5.297(Ft.) 1 . 50(Ac.) 850(Ft/s) Process from Point/Station 910.000 to Point/Station **** SUBAREA FLOW ADDITION **** 910.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 10,87 rain. Rainfall intensity = 4.151(In/Hr) for a Runoff coefficient used for sub-area. Rational Subarea runoff = 3.927(CFS) for 1.720(Ac.) Total runoff = 7.643(CFS) Total area = 100.0 year storra method, Q=KCIA, C = 0.550 3 . 22(Ac. + 44-4-4-4- + - Process from Point/Station 910.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Prograra estiraafed size) **** 912 . 000 Upstream point/station elevation = 208.00(Ft.) Downstream point/station elevation 204. 00 (Ft.) Pipe length = 85.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 7.643(CFS) Nearest computed pipe diameter = 12.00 (In.) Calculated individual pipe flow = 7.643(CFS) Normal flow depth in pipe = 8.39(In.) Flow top width inside pipe = 11.01(In.) Critical depth could not be calculated. Pipe flow velocity = 13.02(Ft/s) Travel time through pipe = 0.11 rain. Tirae of concentration (TC) = 10.98 min. Process from Point/Station 912.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 516.000 Upstream point/station elevation = 204.00(Ft.) Downstream point/station elevation = 185.00(Ft.) Pipe length = 220.00(Ft.) Manning's N= 0.011 No. of pipes = 1 Required pipe flow = 7. 643(CFS) Nearest computed pipe diameter = 12.00(In.) Calculated individual pipe flow = 7.643(CFS) Normal flow depth in pipe = 6.82(In.) Flow top width inside pipe = 11.89(In.) Critical depth could not be calculated. Pipe flow velocity = 16.58(Ft/s) Travel time through pipe = 0.22 rain. Tirae of concentration (TC) = 11.20 min. Process from Point/Station 516.000 to Point/Station **** CONFLUENCE OF MAIN STREAMS **** 516.000 The following data inside Main Stream is listed: In Main Stream nuraber: 2 Stream flow area = 3.220(Ac.) Runoff from this streara = 7. 643(CFS) Time of concentration = 11.20 min. Rainfall intensity = 4.072 (In/Hr) Suitunary of stream data: Stream No. Flow rate (CFS) TC (min) Rainfall Intensity (In/Hr) 1 2 Qmax(1) Qmax(2) 21.586 7.643 1.000 * 0.766 * 1.000 * 1.000 * 16. 92 11.20 1.000 * 1.000 * 0.662 * 1.000 * 3. 120 4 . 072 21.586) + 7.643) + 21.586) + 7.643) + 27 .442 21.930 Total of 2 raain streams to confluence: Flow rates before confluence point: 21,586 7.643 Maximum flow rates at confluence using above data; 27,442 21.930 Area of streams before confluence: 11.070 3,220 Results of confluence: Total flow rate = 27.442(CFS) Time of concentration = 16.922 rain. Effective stream area after confluence 14.290(Ac.) Process from Point/Station 516.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estimated size) **** 518.000 Upstream point/station elevation = lB5.00(Ft.) Downstream point/station elevation = 178.40(Ft.) Pipe length = 90.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 27.442(CFS) Nearest computed pipe diameter = 18.00(In.) Calculated individual pipe flow = 27.442(CFS) Norraal flow depth in pipe = 12.36(In.) Flow top width inside pipe = 16.70(In.) Critical depth could not be calculated. Pipe flow velocity = 21.21(Ft/s) Travel time through pipe = 0.07 min. Tirae of concentration (TC) = 16.99 min. Process from Point/Station 911.000 to Point/Station **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 913.000 Top of street segment elevation = 214.900(Ft.) End of street segment elevation = 211.300(Ft.) Length of street segraent = 95.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance from crown to crossfall grade break = 18.500(Ft.) Slope from gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance frora curb to property line = 10.000(Ft.) Slope frora curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = Manning's N in gutter = 0 Manning's N frora gutter to 2.000(In. ) 0130 grade break 0.0150 Manning's N from grade break to crown = 0.0150 Estimated raean flow rate at midpoint of street = Depth of flow = 0.442(Ft.), Average velocity = Streetflow hydraulics at raidpoint of street travel: Halfstreet flow width = 15.283(Ft.) Flow velocity = 5.65(Ft/s) Travel tirae = 0.28 rain. TC = 17,27 Adding area flow to street Decimal fraction soil group A = 0,000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type 27.557(CFS) 5.651(Ft/s) min. Rainfall intensity = 3.079(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = Subarea runoff = 0.203(CFS) for 0.120(Ac.) Total runoff = 27.645(CFS) Total area = 14.41(Ac.) Street flow at end of street = 27.645(CFS) Half street flow at end of street = 13.823(CFS) Depth of flow = 0.443(Ft.), Average velocity = 5.655(Ft/s) Flow width (frora curb towards crown)= 15.303(Ft.) 0 . 550 Process from Point/Station 913.000 to Point/Station **** STREET FLOW TRAVEL TIME + SUBAREA FLOW ADDITION **** 518.000 Top of street segment elevation = 211.300{Ft.) End of street segment elevation = 191.100(Ft.) Length of street segment = 310.000(Ft.) Height of curb above gutter flowline = 6.0(In.) Width of half street (curb to crown) = 20.000(Ft.) Distance frora crown to crossfall grade break = 18.500(Ft. Slope frora gutter to grade break (v/hz) = 0.020 Slope from grade break to crown (v/hz) = 0.020 Street flow is on [2] side(s) of the street Distance frora curb to property line = 10.000(Ft.) Slope from curb to property line (v/hz) = 0.020 Gutter width = 1.500(Ft.) Gutter hike from flowline = 2.000(In.) Manning's N in gutter = 0.0130 Manning's N frora gutter to grade break = 0.0150 Manning's N from grade break to crown = 0.0150 Estimated mean flow rate at midpoint of street = Depth of flow = 0.413(Ft.), Average velocity = Streetflow hydraulics at midpoint of street travel: Halfstreet flow width = 13.815(Ft.) Flow velocity = 6.98(Ft/s) Travel time = 0.74 min. TC = 18.01 min. Adding area flow to street Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Rainfall intensity = 2.997(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C Subarea runoff = 0.709(CFS) for 0.430(Ac.) Total runoff = 28,354(CFS) Total area = Street flow at end of street = 28.354(CFS) Half street flow at end of street = 14.177(CFS) Depth of flow = 0.414(Ft.), Average velocity = 6.994(Ft/s Flow width (from curb towards crown)= 13. 873(Ft.) 28.058(CFS) 6. 976(Ft/s) 0 . 550 14.84(Ac.) Process from Point/Station 518.000 to Point/Station **** SUBAREA FLOW ADDITION **** 518.000 Decimal fraction soil group A 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 18.01 rain. Rainfall intensity = 2.997(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 1.236(CFS) for 0.750(Ac.) Total runoff = 29.591(CFS) Total area = 15.59(Ac.) Process from Point/Station 518.000 to Point/Station **** SUBAREA FLOW ADDITION **** 518 . 000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Decimal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 18.01 min. Rainfall intensity = 2.997(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method,Q=KCIA, C = 0.550 Subarea runoff = 0.181(CFS) for 0.110{Ac.) Total runoff = 29.772(CFS) Total area = 15.70(Ac.) Process frora Point/Station **** SUBAREA FLOW ADDITION 518.000 to Point/Station 518.000 Decimal fraction soil group A = 0.000 Decimal fraction soil group B = 0.000 Deciraal fraction soil group C = 0.000 Decimal fraction soil group D = 1.000 [SINGLE FAMILY area type ] Time of concentration = 18.01 rain. Rainfall intensity = 2.997(In/Hr) for a 100.0 year storm Runoff coefficient used for sub-area. Rational method, Q=KCIA, C Subarea runoff = 0.033(CFS) for 0.020(Ac.) Total runoff = 29.805(CFS) Total area = 15.72(Ac 0 . 550 Process from Point/Station 518.000 to Point/Station **** PIPEFLOW TRAVEL TIME (Program estiraated size) **** 520 . 000 Upstream point/station elevation = 178.40(Ft.) Downstreara point/station elevation = 174.50(Ft.) Pipe length = 50.00(Ft.) Manning's N = 0.011 No. of pipes = 1 Required pipe flow = 29.805(CFS) Nearest computed pipe diameter = 18.00(In.) Calculated individual pipe flow = 29,805(CFS) Normal flow depth in pipe = 12.87(In.) Flow top width inside pipe = 16.25{In.) Critical depth could not be calculated. Pipe flow velocity = 22.06{Ft/s) Travel time through pipe = 0.04 min. Time of concentration (TC) = 18.05 min. End of computations, total study area = 15.72 (Ac,