Loading...
HomeMy WebLinkAboutCT 06-25; Robertson Ranch PA 21; Robertson Ranch PA 21; 2009-06-02SEWER STUDY FOR ROBERTSON RANCH EAST VILLAGE PA 21 CT 06-25 ou o U Kt .2 ^M» 'a Prepared by: Job No. 01-1014 December 18, 2007 Revised: March 2009 O'DAY CONSULTANTS, INC. 2710 Loker Avenue West Suite 100 Carlsbad, California 92010 Tel: (760)931-7700 Fax: (760)931-8680 Tim Carroll CD DC O CO LJJ 00 RCE 32014 Exp. 12/31/10 Date o z TABLE OF CONTENTS SECTION 1 INTRODUCTION Purpose of Study SECTION 2 1. Vicinity Map 2. Flowrate Generation Criteria, City of Carlsbad, Engineering Standards, Edition 2004 SECTION 3 Explanation of Formulas Used Calculations of Qavg and Qpeak Summary Table of Calculations SECTION 4 Exhibit A - Sewer Analysis Exhibit INTRODUCTION Purpose of Study This sewer analysis was prepared to determine the proposed flow depth and velocities from planning area 21. CITY OF OCEANSIDE SITE CITY OF VISTA OF SAN MARCOS CITY OF ENCINITAS VICINITY MAP NO SCALE E. Flowrate Generation 1) An Equivalent Dwelling Unit (EDU) =* 220 gal/day, Average Daily Flow (ADF) 2) A peaking factor (PR of 2.5 multiplied times the ADF shall be used to determine Peak Daily Flows (PDF). PDF » ADF x 2.5 a) Residential: Single Family Residence = 1 EDU b) Commercial Property: 1 EDU/1,800 ft2 (building space) i) To convert raw land to square feet of building space, assume 30% coverage. This could vary significantly dependent development constraints. ii) To convert improved pads to square feet of building space, assume 40% of coverage. 5. 3) Industrial Property:1 EDU/5,000 ft* (warehouse space) 1 EDU/1,800 ft2 (office space) a) To convert raw land to square feet of building space, assume 30% coverage. This could vary significantly dependent issues such as environmental restrictions. b) To convert improved pads to square feet of building space, assume 40%of coverage. c) Assume 60% of building space is warehouse, and 40% is office space. HORIZONTAL AND VERTICAL LAYOUT A. Streets: See City of Carlsbad Standard Drawing No. GS6 for location. Alley: Main to centerline shall be a minimum of three feet (3*) offset.B. C. D. Private Street:Shall require special design and conditions. Easement shall be20 feet Horizontal Curve: SDR 35, PVC pipe may be curved horizontally with thefollowing limitation: City Engineer shall approve curvatures for larger diameter pipe. ,EST ORIGINAL Page 3 of 12 EXPLANATION OF FORMULAS 1. EDU Determined per the City of Carlsbad Engineering Standards, Edition 2004 to be 1 EDU per Single Family Residence. 2. Average Daily Flow (ADF) Determined to be 220 gal/day/EDU per the City of Carlsbad Engineering Standards, Edition 2004. 3. Average Flow (Qavg) EDU x ADF (Then convert to cfs) 4. Peak Factor Determined to be 2.5 per the City of Carlsbad Engineering Standards, Edition 2004. 5. Peak Flow (Qpeak) 2.5 x Qavg 6. Calculations for Velocity & Depth of Flow Using CivilCad 4/1/2009 Page 1 of 1 Robertson Ranch PA 21 - Proposed Sewer Analysis Pipe Reach 1 2 3 A.H. #'s 6 to 5 5 to 4 4 to 3 Units 53-68 41-52,69-80 37-40,81-84 Total EDU's 16 40 48 Qavg (cfs} 0.005 0.014 0.016 Qpeak (cfs) 0.014 0.034 0.041 Pipe Diam. (in.) 8 8 8 Pipe Slope (%) 1.00 1.06 0.84 Depth of flow (ft) (n=0.011) 0.046 0.070 0.081 D/d (n=0.011) 0.07 0.11 0.12 Pipe Velocity (fps) (n=0.011) 1.33 1.74 1.7 G:\011014VPA 21\SEWER\Robertson Ranch PA 21_SewerAnalysis.xls 'dJSTHlO 'do 6002 '10 ;lin/t'LlO BMp'tOZlf UO\LZVd\s)iq!MX3\t>louO\:0 ,001 = ,003 ,05 ,001 ,5Z ,0 — -S — e^-^ —• — -s — • U3M3S ONU.SIX3 U3M3S 31VAMd U9 I3M3S ,,9 UO at U3M3S OIlBfld K8 ON3O31 IZVd V 9Wd Nl S3liniOVJ V3M3S (3( 1I8IHX3 '3A V N310 NO U3M3S S3NI1 M3M3S 31VAIUd A3 Q3DIAU3S 39 01 HO 9£ O'Day Consultants Inc. 2710 Loker Avenue West, Suite 100 Carlsbad, CA 92008 Tel: (760) 931-7700 Fax: (760) 931-8680 Inside Diameter ( 8.00 in.) * * it * Water * ( 0.97 in.) ( 0.081 ft.) * * * * I * v Circular Channel Section Flowrate 0.041 CFS Velocity 1.700 fps Pipe Diameter 8.000 inches Depth of Flow 0.971 inches Depth of Flow 0.081 feet Critical Depth 0.094 feet Depth/Diameter (D/d) 0.121 Slope of Pipe 0.840 % X-Sectional Area 0.024 sq. ft. Wetted Perimeter 0.474 feet AR*(2/3) 0.003 Mannings 'n' 0.011 Min. Fric. Slope, 8 inch Pipe Flowing Full 0.001 % O'Day Consultants Inc. 2710 Loker Avenue West, Suite 100 Carlsbad, CA 92008 Tel: (760) 931-7700 Fax: (760) 931-8680 Inside Diameter ( 8.00 in.) * * * * * Water * ( 0.84 in.) ( 0.070 ft.) * * * Circular Channel Section Flowrate 0.034 CFS Velocity 1.739 fps Pipe Diameter 8.000 inches Depth of Flow 0.841 inches Depth of Flow 0.070 feet Critical Depth 0.087 feet Depth/Diameter (D/d) 0.105 Slope of Pipe 1.060 % X-Sectional Area 0.020 sq. ft. Wetted Perimeter 0.440 feet ARA(2/3) 0.002 Mannings 'n' 0.011 Min. Fric. Slope, 8 inch Pipe Flowing Full 0.001 % O'Day Consultants, Inc. 2710 Loker Avenue West, Suite 100 Carlsbad, CA 92008 Tel: 760-931-7700 Fax: 760-931-8680 t ******* * * * * Inside Diameter ( 8.00 in.) Water ( 0.55 in.) ( 0.046 ft.) Circular Channel Section Flowrate 0.014 CFS Velocity 1.329 fps Pipe Diameter 8.000 inches Depth of Flow 0.553 inches Depth of Flow 0.046 feet Critical Depth 0.046 feet Depth/Diameter (D/d) 0.069 Slope of Pipe 1.000 % X-Sectional Area 0.011 sq. ft. Wetted Perimeter 0.355 feet AR"(2/3) 0.001 Mannings 'n' 0.011 Min. Fric. Slope, 8 inch Pipe Flowing Full 0.000 %