HomeMy WebLinkAbout3537; Vista/Carlsbad Interceptor Sewer; Agua Hedionda Sewer Access Road; 1998-07-14AGRA Earth & Environmental AGRA Earth &
Environmental, Inc.
16760 West Bernardo Drive
San Diego, CA 92127
Inlv-U 1QQR Tel <619>487-2113July ^e^, nyyo Fax (619)487-2357
Job No. 8-252-102100
Ms. Meleah Ashford
Dudek & Associates
605 Third Street
Encinitas, California 92024
RE: GEOTECHNICAL INVESTIGATION
AGUA HEDIONDA SEWER ACCESS ROAD
CARLSBAD, CALIFORNIA
Dear Ms. Ashford:
INTRODUCTION
This report presents the results of the geotechnical investigation AGRA Earth & Environmental
(AEE) performed for the new access road planned for the alignment of the existing Agua
Hedionda Sewer line in Carlsbad, California. The location of the new road is shown on the Vicinity
Map on Page 2.
The access road is to be constructed along the 15-foot wide easement for the sewer line adjacent
to the north shore of the Agua Hedionda Lagoon between Hoover Street and Cove Drive, a
distance of about % mile. The road is to be 12 feet wide and will be used by the Carlsbad
Municipal Water District for maintenance of the sewer. The road also is to provide protection from
erosion.
SCOPE OF WORK
The scope of work consisted of a geologic reconnaissance, field exploration, laboratory testing,
analysis of data and preparation of this report. The field exploration program included six test
borings advanced to depths of four to five feet using a hand auger. The logs of the test borings
are contained in Appendix A. Soils are classified according to the Unified Soil Classification
System which is explained in Appendix A.
The laboratory program consisted of moisture content determinations, a direct shear test and a
sieve analysis. Based on the results of the sieve analysis and visual classification of subsurface
materials encountered in the borings, an R-value was estimated for pavement design.
The results of the field exploration and laboratory test programs were analyzed to develop
conclusions and recommendations regarding:
} Recycled Paper
North
Reference:
Microsoft® Expediaru
Streets98 AGUA HEDIONDA SEWER ACCESS ROAD
CARLSBAD, CALIFORNIA
VICINITY MAP
AGRA
Earth & Environmental
JJS JJS 07/07/98 8-252-10210C
-2-
Ms. Meleah Ashford
Dudek & Associates
Agua Hedionda Sewer Access Road
Job No. 8-252-102100
July 14, 1998
PageS
1. Grading for the access road.
2. Erosion potential.
3. Slope stability.
4. Gravel thickness for road construction.
SURFACE AND SUBSURFACE CONDITIONS
The ground surface above the existing sewer line is nearly flat along most of the alignment. The
ground surface adjacent to the alignment on the east and west ends is nearly level. Slopes
typically about 2:1 (horizontal:vertical) with local near-vertical portions abut the central part of the
alignment on the north and south sides. The slopes ascend to the north and east and descend
toward the lagoon on the south and west sides.
The six test borings drilled for this investigation encountered fill soils to the maximum depth
explored, five feet, except for Boring 3. Natural materials were encountered at a depth of three
feet in this boring. These natural soils continued to the depth explored in this boring, five feet.
The fill soils, probably backfill placed during sewer line installation, typically consist of medium
dense silty or clayey sand, with some local zones of relatively clean sand. The natural materials
consist of medium dense clayey sand and medium stiff clayey silt lagoon deposits.
Formational materials observed at the ground surface in numerous exposures both north and
south of the alignment consist of Santiago Formation sandstone and Terrace Deposits sandstone
or conglomerate. The Santiago Formation at some locations contains siltstone and claystone
layers that pose potential stability problems. No siltstone or claystone materials were observed
during the site reconnaissance, but these materials could be exposed by excavation.
Free groundwater was not encountered in the borings, although abundant seepage was noted in
those borings drilled near sea level. The relatively fine-grained soils comprising the fill at most
locations retard the flow of water, and seepage is expected in excavations open more than a few
hours. Groundwater can be anticipated to be at, or slightly above, the level of the water in the
lagoon. The groundwater level will vary somewhat with tidal fluctuations.
AGRA Earth & Environmental^•r
| Recycled Paper
Ms. Meleah Ashford
Dudek & Associates
Agua Hedionda Sewer Access Road
Job No. 8-252-102100
July 14, 1998
Page 4
CONCLUSIONS AND RECOMMENDATIONS
General
The minor grading expected for construction of a new access road can be accomplished with
medium-duty equipment. No evidence for slope instability was observed during the site
reconnaissance and field exploration program. However, excavations should be observed by an
engineering geologist who will check for the presence of adversely-oriented siltstone or claystone
layers which may have a potential for sliding. Slopes can be as steep as 2:1 (horizontakvertical)
in fill and 1-1/2;1 in formational materials from an overall stability standpoint. However, erosion
potential increases significantly on steeper slopes, and slopes as flat as practical will assist in
minimizing erosion. Outside of the roadway area, exposed soil areas should be planted as soon
as possible following grading with vegetation suitable for the near-shore environment and which
will reduce erosion potential. The new road can be constructed with a gravel surface course, or
asphalt concrete pavement surface course can be used. Alternatives for both types of road
surface are described below.
Site Preparation and Grading
The roadway alignment and any adjacent areas where fill will be placed should be stripped of
grass, weeds and the upper 4 inches of soil containing roots and organic debris. Along the road
alignment where the existing ground level will be at final subgrade, the surface exposed by
stripping should be scarified to a depth of 12 inches. Beneath new fill areas, the surface should
be scarified to a depth of at least 8 inches. Following scarification, the soils should be moisture
conditioned to between 1 and 3 percentage points above optimum moisture content and
compacted to at least 95% relative compaction within 12 inches of the bottom of the roadway
gravel or base course, and 90% elsewhere. If cuts will be made for the new road, existing soils
should be over-excavated, replaced and compacted as necessary to obtain a 12-inch thick
subgrade layer compacted to 95% relative compaction. Optimum moisture content and relative
compaction should be based on the ASTM D 1557 laboratory test method.
On-site materials can be used as fill. Imported material, if any, should not contain rocks or lumps
greater than 4 inches in maximum dimension or organic debris. Imported material should have an
Expansion Index of 40 or less. Fill should be placed in lifts 8 inches or less in loose thickness,
moisture conditioned to between 1 and 3 percentage points above optimum moisture content and
compacted to at least 90% relative compaction. The upper 12 inches of subgrade soil beneath the
new roadway should be compacted to at least 95% relative compaction.
4^ AGRA Earth & Environmental
I Recycled Paper
Ms. Meleah Ashford
Dudek & Associates
Agua Hedionda Sewer Access Road
Job No. 8-252-102100
July 14, 1998
Page5
Cut and Fill Slopes
As noted above, fill slopes should not be steeper than 2:1. Due to the potential for erosion along
the lagoon edge, flatter slopes should be provided if practical. Fill slopes should be over-built and
then trimmed back to expose the compacted surface. Cut slopes in existing fill should not be
steeper than 2:1 and cut slopes in formational materials should not be steeper than 1-!4:1 from
the standpoint of stability. Due to the potential for erosion, flatter slopes would be desirable.
Final surface grades should be designed to prevent the flow of rainfall runoff over the faces of
slopes. Attention should be given to existing natural drainage channels, and existing grades
modified as necessary to prevent flow in the channels from eroding the new roadway. A cut-off
trench or v-ditch may be appropriate along the side of the road away from the lagoon.
Erosion-resistant vegetation should be planted as soon as possible after grading. It is
recommended that a landscape architect familiar with vegetation appropriate for the coastal
environment be consulted to determine suitable ground cover for graded locations outside of the
roadway.
New Road Structural Section
It is understood that new road will provide access along the sewer line for routine maintenance
and improvement. Relatively light traffic consisting of light-to medium-weight trucks is anticipated.
Based on inspection of samples collected during the subsurface exploration program and the
results of a sieve analysis on the soil sample judged to have the highest clay content, an R-value
of 25 was estimated for most of the material along the new road alignment.
On this basis, a gravel road surface consisting of 12 inches of Caltrans Class 2 Aggregate Base
(AB), or equivalent, is considered appropriate. An additional 6 inches of AB can be added to
provide additional erosion protection or if heavy truck traffic is expected.
A flexible pavement section consisting of an asphalt concrete surface course over aggregate base
course may be more resistant to erosion and have a longer service life than a gravel road. The
determination of which type of road to construct can be based on relative economics. For light
truck traffic, a section consisting of 2-Yz inches of asphalt concrete (AC) over 6 inches of AB will
be appropriate. For heavy truck traffic, the structural section should be increased to 3-Yz inches
of AC over 11 inches of AB.
AGRA Earth & Environmentalw
) Recycled Paper
Ms. Meleah Ashford
Dudek & Associates
Agua Hedionda Sewer Access Road
Job No. 8-252-102100
July 14, 1998
Page 6
CLOSURE
We trust that this report provides the information you need. If you have any questions, or need
additional information, please call me at (619) 487-2113.
Sincerely yours,
AGRA Earth & Environmental
/Games J^/Stone, RGE 808
Principal Engineer
JS/jjs
Distribution: (6) Addressee
Attachment: Appendix A - Logs of Test Borings
Appendix B - Laboratory Testing
Figure 1 - Site Plan
8-252-102100/f\report
AGRA Earth & Environmental
( Recycled Paper
APPENDIX A
UNIFIED SOIL CLASSIFICATION
»•»••-»•"••'••*-**•
Pt
Highly
Organic
soils
44
OH ^CH MH
Silts and clays
Liquid Limit >50%
Him HI
OL
//
CL ML
Silts and days
Liquid Limit <50%
Fine grained soils
(More than 50% is smaller than No. 200 sieve)
msc SM
Sands with fines>12% fines
SP sw
Clean sands<5% fines
Sands - more than 50% of coarse
fraction is smaller than No. 4 sieve
_-->
GC
i*\-
GM
Gravels with fines> 12% fines
-vj
GP
• *•* "
GW
Clean gravels<5% fines
Gravels - more than 50% of coarse
fraction is larger than No. 4 sieve
Coarse grained soils
(More than 50% is larger than No. 200 sieve)
60
20
CL
CL
41^
OH4MH
LABORATORY CLASSIFICATION CRITERIA
GW and SW - Cu = D«, /D,« greater than 4 for GW and 6 for SW
Cc = $ I(Q xQ ) between 1 and 3
GP and SP - Clean Gravel or sand not meeting requirements for GW and SW
GM and SM - Atterberg Limit below "A-LINE" or P.I. less than 4
GC AND SC - Atterfaerg Limit above "A-LINE" or P.I, greater than 4
SILT OR CLAY FINE
SAND
MEDIUM
SAND
COARSE i
SAND :
SIEVE SIZE 200 40 10 4
FINE
GRAVEL
COARSE
GRAVEL COBBLES BOULDERS!
Vf 3' 10-
20 40 60 80
LIQUID LIMIT
100
Classification of earth materials is based on field inspection and should not be
construed to imply laboratory analysis unless so stated.
MATERIAL SYMBOLS
Extrusive Igneous
Rock
Asphalt
Claystone
Clayey Sandstone
Clayey Siltstone
Metamorphic Rock
Intrusive Igneous
Rock
Interbedded
Limestone and
Shale
Limestone
Sandy Claystone
Sandstone
Sandy Siltstone
Siltstone
Silty Claystone
Silty Sandstone
LEGEND OF PENETRATION TEST
i ,<D 0
O
5
15
30
10
20
55
15
*-!_
^
— I /Graphi
/
i
|
c representat
driving rate
u
on of
Blows per foot =25 50 75
Blows per foot
(using 140 Ib. hammer with 30" drop = 350 ft-lb blow)
Consistency Classification
for Soils
According to the Standard Penetration Test
Blows/Ft.*
0-5
Granular
Very loose
6-10 Loose
11-30
31-50
>50
Medium Dense
Dense
Very dense
Blows/Ft.* Cohesive
0-5 Very soft
6-10 Soft
11-20
21-35
36-70
Medium Stiff
Stiff
Very Stiff
>70 Hard
LEGEND OF BORING
G.W.S. ^ —
Conformable material change
Approximate material change
Unconformable material change
Bottom of boring
"NSR" indicates "no sample recovery"
Job No. 8-252-102100 A-1
AG RA EARTH & ENVIRONMENTAL, INC.
TEST BORING LOG
TYPE 4" Hand Auger
STRIKE/DIPand otherDEPTH-SPECIFICNOTESDRY DENSITY<PCf)9.3
MOISTURE(X)BLOWS/FOOTbag
SAMPLE SIZE( i nches)1
SAMPLE NO.1
2
3
-
•T™ QJfl^ J!j
ELEVATION "7.Q feet BORING B- 1
''&
$/'w
p
^•'•'••.
-.';;'
I '. .
y
_i
HOa; CQIJE
sc
SM
0(/>LU<T
J-OH
O
FILL: Brown and gray-black CLAYEY SAND, medium dense,
moist, with some GRAVEL
Mottled brown and red-brown fine to medium SILTY
SAND, medium stiff, saturated, with some CLAY and
GRAVEL
NOTES:
1. Total depth of boring = 4 feet.
2. No free groundwater encountered.
3. Boring backfilled with cuttings on 06/11/98.
4. Elevation from plan provided by Dudek & Associates,
undated.
THIS BORING LOG SUMMARY APPLIES ONLY AT
TIME AND LOCATION INDICATED. SUBSURFACE
CONDITIONS MAY DIFFER AT OTHER LOCATIONS
AND TIMES.
LOGGED BY WMC DATE 6-11-98
Job No. 8-252-102100 - July 7, 1998 A-2
AG RA EARTH & ENVIRONMENTAL, INC.
TEST BORING LOG
TYPE 4" Hand Auger
STRIKE/DIPand otherDEPTH -SPECIFICNOTESDRY DENSITY(pcf)8.4
18.7
MOISTURE(*)BLOWS/FOOTbag
bag
SAMPLE SIZE( inches)1
2
d
LU
Q_
to
1
2
3
—
— .
n~ <U
LJ£ i
^ C
ELEVATION "6.0 feet BORING B- 2
^Ii in i di\j.ni_SYMBOLSM
SM
coOCOLUC:
U.CJHZ_JZ3H
OCO
FILL: Brown and yellow-brown fine SILTY SAND, medium
dense, moist, with some roots
wet below 1.2 feet
Brown fine to coarse SILTY SAND, medium dense,
wet, with some CLAY and GRAVEL
NOTES:
1. Total depth of boring = 4 feet.
2. No free groundwater encountered.
3. Boring backfilled with cuttings on 06/11/98.
4. Elevation from plan provided by Dudek & Associates,
undated.
THIS BORING LOG SUMMARY APPLIES ONLY AT
TIME AND LOCATION INDICATED. SUBSURFACE
CONDITIONS MAY DIFFER AT OTHER LOCATIONS
AND TIMES.
LOGGED BY UMC DATE 6-11-98
Job No. 8-252-103100 - July 7, 1998 A-3
AG RA EARTH & ENVIRONMENTAL, INC.
TEST BORING LOG
TYPE 4" Hand Auger
STRIKE/DIPand otherDEPTH-SPECIFICNOTESDRY DENSITY<pcf)9.0
21.7
MOISTURE<X)BLOUS/FOOTbag
bag
SAMPLE SIZE( \ nches)1
2
O
UJ
Q_
CO
1
2
3
4
—
—DEPTH(feet)ELEVATION ^2.0 feet BORING B- 3
i
ifi/%
f
,
^I MATERIALI SYMBOLSM
SC
SC
ML
COQCOLU<C
U_OH
OCO
FILL: Brown fine to coarse SILTY SAND, medium dense,
moist, with some CLAY
Brown fine to coarse CLAYEY SAND, medium dense,
wet
NATURAL: Gray-black CLAYEY SAND, medium dense,
saturated
Gray CLAYEY SILT, stiff, saturated
NOTES:
1. Total depth of boring = 5 feet.
2. No free groundwater encountered.
3. Boring backfilled with cuttings on 06/11/98.
4. Elevation from plan provided by Dudek & Associates,
undated.
THIS BORING LOG SUMMARY APPLIES ONLY AT
TIME AND LOCATION INDICATED. SUBSURFACE
CONDITIONS MAY DIFFER AT OTHER LOCATIONS
AND TIMES.
LOGGED BY UMC DATE 6-11-98
Job No. 8-252-102100 - July 7, 1998 A-4
AG R A EARTH & ENVIRONMENTAL, INC.
TEST BORING LOG
TYPE 4" Hand Auger
STRIKE/DIPand otherDEPTH-SPECIFICNOTESDRY DENSITYCpcf)5.3
11.2
MOISTURE(X)BLOWS/FOOTbag
bag
SAMPLE SIZECinches)1
2
*o
LU
QL
<E
1
2
4
— •
— ;
a""''' a
§5 :
ELEVATION ^9.0 feet BORING B- 4
'••'loauAS ISM
SM
SM
SM
QU)LU<C
u-dH
I3HOU)
FILL: Black fine SILTY SAND, medium dense, moist
Black fine to coarse SILTY SAND, medium dense,
moist, with some CLAY
Black fine to coarse SILTY SAND, medium dense,
wet, with some GRAVEL and CLAY
Yellow-brown fine to coarse SILTY SAND, medium
dense, wet
NOTES:
1. Total depth of boring = 5 feet.
2. No free groundwater encountered.
3. Boring backfilled with cuttings on 06/11/98.
4. Elevation from plan provided by Dudek & Associates,
undated.
THIS BORING LOG SUMMARY APPLIES ONLY AT
TIME AND LOCATION INDICATED. SUBSURFACE
CONDITIONS MAY DIFFER AT OTHER LOCATIONS
AND TIMES.
LOGGED BY UMC DATE 6-11-98
Job No. 8-252-102100 - July 7, 1998 A-5
AG R A EARTH & ENVIRONMENTAL, INC.
TEST BORING LOG
TYPE 4" Hand Auger
STRIKE/DIPand otherDEPTH-SPECIFICNOTESDRY DENSITY<PCf)13.0
14.0
MOISTURE<X)BLOWS/FOOTbag
bag
SAMPLE SIZEC inches)1
2
SAMPLE NO.2
3
—
—DEPTHCfeet)ELEVATION ~12.0 feet BORING B- 5
%
1
;•_'/.•'
1V
1 MATERIAL1 SYMBOLSM
SC
SP
•
QU)uj<r
H_JLLUH
IDHO
FILL: Brown fine to coarse SILTY SAND, medium dense.
moist
Light brown to yellow-brown fine to coarse
CLAYEY SAND, medium dense, wet
Green-brown fine to coarse SAND, medium dense,
wet, with minor amounts of GRAVEL
NOTES:
1. Total depth of boring = 4 feet.
2. No free groundwater encountered.
3. Boring backfilled with cuttings on 06/11/98.
4. Elevation from plan provided by Dudek & Associates,
undated.
THIS BORING LOG SUMMARY APPLIES ONLY AT
TIME AND LOCATION INDICATED. SUBSURFACE
CONDITIONS MAY DIFFER AT OTHER LOCATIONS
AND TIMES.
LOGGED BY UMC DATE 6-11-98
Job No. 8-252-102100 - July 7, 1998 A-6
AG RA EARTH & ENVIRONMENTAL, INC.
TEST BORING LOG
TYPE 4" Hand Auger
STRIKE/DIPand otherDEPTH-SPECIFICNOTESDRY DENSITY(pcf)5.1
16.2
MOISTURE(X)BLOWS/FOOTbag
bag
SAMPLE SIZE( i nches)1
2
SAMPLE NO.1
2
3
4
—
—
—
—DEPTH(feet)ELEVATION "2.0 feet BORING B- 6
^
^
M
H
if
i|§£
%1 MATERIAL| SYMBOLSC
SM
SC
<nocnLUCCH_lh°Z-JIDHO(rt
FILL: Brown fine to coarse CLAYEY SAND, medium dense,
moist, with some GRAVEL
Red-brown SILTY SAND, medium dense, wet
Yellow brown fine to coarse CLAYEY SAND, medium
dense, saturated
...color change to gray-brown
NOTES:
1. Total depth of boring = 5 feet.
2. No free groundwater encountered.
3. Boring backfilled with cuttings on 06/11/98.
4. Elevation from plan provided by Dudek & Associates,
undated.
THIS BORING LOG SUMMARY APPLIES ONLY AT
TIME AND LOCATION INDICATED. SUBSURFACE
CONDITIONS MAY DIFFER AT OTHER LOCATIONS
AND TIMES.
LOGGED BY UMC DATE 6-11-98
Job No. 8-252-102100 - July 7, 1998 A-7
APPENDIX B
Ms. Meleah Ashford
Dudek & Associates
Agua Hedionda Sewer Access Road
Job No. 8-252-102100
July 14, 1998
Page B-1
APPENDIX B
LABORATORY TESTING
The laboratory test program for the geotechnical investigation was designed to fit the specific
needs of this project. Testing was limited to on-site materials obtained during subsurface
exploration activities. A brief description of each type of test performed is presented below.
Results of the laboratory program are provided on the following page and on the test boring logs
in Appendix A.
In-situ moisture contents were determined for most samples. Data obtained are listed on the
boring logs in Appendix A.
Strength characteristics were determined in the laboratory by a direct shear test performed on one
sample in accordance with ASTM D 3080 procedures. The sample was remolded to an estimated
90% relative compaction and tested at three confining pressures in a 2.5-inch diameter circular
shear box using a controlled displacement rate. Resultant data are listed in Table 1.
The grain size distribution of one sample was determined in accordance with ASTM D 422.
Results are presented graphically on Page B-2.
Remaining samples collected during the field exploration program are stored in the laboratory for
future reference and analysis, if needed. Unless a request is received to the contrary, all samples
will be discarded 30 days from the date of this report.
TABLE 1
SUMMARY OF
DIRECT SHEAR TEST RESULTS
(ASTM D 3080)
Boring No./
Sample No.
2/1
Normal Stress
(psf)
1125
2160
3195
Peak Shear Stress
(psf)
794
1506
2236
Shear Stress at
0.25 inch displacement
(psf)
794
1506
2236
AGRA Earth & Environmental
I Recycled Paper
100
90
PERCENT PASSING (BY WEIGHT)) A. Ol O) ~J 0> o o o o cJU
20
10
°5
US STANDARD SIEVE SIZE
3,, 2" r/S" 1" %" 1/2"34: No. 4 No. 8 No. 16 No. 30 No. 50 No. 100 No. 200
00
BOULDERS
1
ii
i
iii
100 50
COBBLES
Sample No.
or Location
6/1
I
|
I
I
"*"t •^*
S
1
\
\
^S>'\,k%k
N
|^
\\
\t\
\\
t
V\
y \
l
s
'1 1
10 5 1.0 0.5 0.1 0.05 0.01 0.005 0.001
GRAIN SIZE IN MILLIMETERS
GRAVEL
Coarse Fine
SAND
Coarse Medium Fine
TestDate USCS
6/22/98 SC
Description
Clayey Sand
Natura
Water
5.1
LL PL PI SE Max. Dry
Density
Optimum
Water
Fines (Silt and Clay)
GRAIN SIZE DISTRIBUTION
4-^ AGRA Earth & Environmental
Project: Agua Hedionda Sewer Access Road
By: WMC Date: 07/07/98