Loading...
HomeMy WebLinkAbout5501-2; BUENA INTERCEPTOR SEWER BIOLOGICAL ODOR CONTROL; SUBMITTALS; 2018-03-13' t,Iw7,ji, ' . LIcdIAS493O9. J.7ILFCr,17J%J: - - . DATE: PROJECT NAME / BID NUMBER: March 13, 2018 City of Vista - Rehabilitation of 14 Sewer Manholes on Buena Vista Trunk Line TO: FROM: City of Vista Orion Construction COrporation 1165 E. Taylor Street 2185 La Mirada Drive Vista, CA 92084-3303 - Vista, CA 92081 ; ATTN: - .. Chris Dzwigalski . Eric Kelley, Project, Engi nee r.. CDZWTGALSKI@ci.vista.ca.us Eric.kelley@orionconstruction.com - Drawings or Data are Submitted: For Approval Z For Information .- '- .• - Number Drawing Supplier & Subject of Submittal Specification. of Copies Number . . Section(s) 1 n/a Traffic Plan / . . n/a . - .: - - (a) We have verified that the material or equipment contained in this submittal CHECK ONE meets all the requirements specified or shown (no exceptions) ;-: This is: - 1stSubmittal Submittal (b) • We have verified that the material or equipment contained in this submittal • •L,' meets all the requirements specified or shown, except for the following deviations (list deviations or attach letter): . . . . -. • • 1 -: - •1 Submittal 4*: 1 - j . '. • . . -- Activity 4* Record float: REMARKS: . . - - - •• - * - . . - - *.-- CONTRACT'S AUTHORIZED SIGNATURE: \\\ Z 10 Fi 210 SHIFT IAE fPIR 50 ---------------- t~250 BK K 1L ---- .00 40' CONE N SPACING I'YPICAL CONSTRUCTION SIGNS: ML PUNS lAiN BE O(EOiN MID APPROAD AT NE MISMD4TM. PCE ON AMOM (AMID M(NNACTMI 0MB NE ROAMYS SHOW ON WS KAM PRIOR M 7W PLAN BONO MY INTO UW &L RAMS AM WDW M OONTM - TRAFFIC CONTROL PLAN <9> <e> Q> <*> <s> THE UMIJPL 01 WWM IRAFHC OWMM MWIM, BID INISTOOB / NGITRIETMI ID WFUMME 101 TIE ATAtINC ANTTIDIM. ANGICY FEMMMM FOR WORK KO.P0 Mi0MB WIM MATOIDIT. MO ClIMB lAMES NO IDlIL&TDlS. In 10(NMT TRAFFICMBITRIDS IMOT IM IISTALiED PAN THE AGENCY MIPI1OIAD PUN TO IM IDIECTIHE AND OUNAN COMM I PLAN APPROVINI BY: 011101 11101 111MB AAIJS1MINT. MM IM RIMMED IN MONO BY A RMESENTAM OF THE MBMBALTITAL MONEY. OR MANIA MB01 OVER NE RMVWAY ORION CONSTRUCTION I CITY OF CARLSBAD I VIM-I CIA(CAJ -2 BA7A V100 C30W All-I VIA-I? PAiN IAH.EADITATIOI MID MIHIHE PI.AESIMNT (NIDAD IM PAIDONIES AT (IDIIDD / TREND PMSONMEL 2185 LA MIRADA DR HUDSON SAFET-LITE RENTALS 11215 NO ,ipotpn y NE wsTDl / MBHRACT(N TO tCTit ll0ITO NO I*AIIIDIMNE FIEIDMBCY IS OCTANE BY PlAiD MBCT0 WI lOT LAN NAil DALY VISTA, CA 92081 760-597-9660 N MARSHAlL AVE Ia CAJON, CA 92020 IooB 619-441-364-4 BY: LEGEND: c09& •SIGN TOOK AROA TRAPTOC SSSICTTOB PtANHING ARSON SIGN: SIGNAL ® FLAG rBABSICNDE TRSP05050 NO P05911(0: -TNP- INY OARS IPSOIRS SPESII LANE I501OK 1090716 15100 SPALSJ(G: IGNJ91 SPACING: OTOI SPWT'IJlt IllS NO MBI1 0501. MI OIY F TRIflE AXND. PAM IIPWIDITA1IOI MO BClTOl BY OTHERS.0 I IS DITASACPY lIONEl 511E1'UIE 101 iN6 MANE ANAMOIC FAIIIX TO IISTIAL I I SC01 S0900VAL iJATE DRAIN: ISCAl& - I110G BOILERS - 3-12-18! ______ SEE PLAN! SEE PLAN! SEE PLANI SEE PLAN 3-8--18I NO SCALE"' 1 OF 1 m 1"A , W "' Lic.#A549309 C7 111W M 7 I?.IJ C7 l Al' ii IV , -/'• DATE: • PROJECT NAME / BID NUMBER: March 13, 2018 City of Vista — Rehabilitation of 14 Sewer Manholes on Buena Vista Trunk Line TO: FROM: Cityof Vista Orion Construction Corporation 1165 E. Taylor Street . 2185 La Mirad Drive Vista, CA 92084-3303 Vista, CA 92081 ATTN: . - :• ' '. Chris Dzwigalski Eric' Kelley, Project Engineer .. -- CDZWTGALSKl@ci.vista.ca.us Eric.kelley@orionconstruction.corñ. Drawings or Data are Submitted For Approval 0 For Information Lil Number Drawing Supplier & Subject ofSubmittaI' ' .3 •;' Specification of Copies Number . ' '• Section(s) 1 n/a Safety Plan (Sancon Engineering) n/a - ' t - - ' . - 'p.-' t.. ' . . , •-t;. . . - .(a) We have verified that the material or equipment contained in this submittal:. CHECK ONE meets all the requirements specified or shown (no exceptions) -This is 1St Submittal 2nd Submittal L (b) We have verified that the material or equipment contained in this submittal'.-, meets all the requirements specified or shown, except for the following . deviations (list deviations or attach letter) 71, Ji Submittal #: 2 Activity # " Record float REMARKS •••' I ' - ' .•' 1* •, ,, t''.'-.''1.-' ,••t •._ '.- 'I - ' •• •- -• ,; -- . - • : ;_• CONTRACT'S AUTHORIZED SIGNATURE ' Erc& K&lteg - a . : •-. --- • •' ' •. / p ' ' ' - :' , I •,• -• 2185 La Mirada Dr, Vista, CA 92024 (760) 597-9660 Phone (760) 597-9661 Fax - ' 1' I , - a -, • -) 4' •' ,.• — hCON,. ; ENGINEERING,, INC. LIC #731797 SAFETY PLAN INJURY AND ILLNESS PREVENTION PROGRAM (IIPP) / Revised May 2017 INCLUDES: Codes of Safe Work Practices Confined Space Entry Program Heat Illness Prevention Plan Hazard Energy Control Program •. (Lockout Tag-Out) • TABLE OF CONTENTS I. INTRODUCTION INTRODUCTION........... . ...................................................................... 3 IDENTIFICATION OF PLAN ADMINISTRATORS .......................... .............. 4 EMPLOYEE RESPONSIBILITIES .............................................................5 II. SAFETY COMMUNICATION SYSTEMS FOR EMPLOYEES TO INFORM EMPLOYER OF HAZARDS ............. .8 SYSTEM FOR IDENTIFYING AND EVALUATING WORKPLACE HAZARDS.... 8 - III. INSPECTIONS AND REPORTS ACCIDENT REPORTING REQUIREMENTS ................................................. 9 ACCIDENT INVESTIGATIONS AND REPORTS ................................... . ....... 9 SAFETY INSPECTIONS..............................................................................11 SAFETY INSPECTION REPORT (FORM) .................................................... .12 WORKPLACE SAFETY INSPECTION (FORM) ............... ................... ................ 14 IV CODES OF SAFE WORK PRACTICES ' GENERAL SAFETY RULES......................................................................16 SPECIFIC SAFETY RULES ..................................................................... 17 VEHICLESAFETY ......................................................... ....................... 24 • DISCIPLINARY PROCEDURES ................... ................................. . ........... 25 V. TRAINING • TRAINING ANt) INSTRUCTION ........................... . ............ ....................... 25 TAILGATE SAFETY TALKS ..................... ........ ......................................... 27 HAZARDOUS ENERGY CONTROL PROGRAM ........................................... 28 PERMIT REQUIRED CONFINED SPACE RULES AND REGULATIONS ............ .32' RESPIRATOR PROGRAM ........ . .......................... . ............. ....................... .46 FIRST AID AND EMRGENCY PLANNING..................................................50 HEAT ILLNESS PREVENTION PLAN .......................................................... 51 HAZARD ENERGY CONTROL PROGRAM (LOCKOUT TAG-OUT) ....................54 VII: APPENDIX HEAT ILLNESS PREVENTION REGULATION AMENDMENTS .......................... 57 / • 2 ' .• ••. • INTRODUCTION It is the policy of Sancon Engineering that every employee is entitled to a safe and healthful place in which to work. T6 this end, every reasonable effort will be made in the interest of Accident Prevention, Fire Protection and Health Preservation. The Injury and Illness Prevention Program must include a system for communication "in a form readily understandable by all affected employees" on matters relating to occupational safety and health. The system must have "provisions designed to encourage employees to inform the employer of hazards at the worksite without feai of reprisal." Compliance includes: Meetings: Training Programs: Posting on a bulletin board: Written communications: A suggestion box or similar anonymous system for employees to notify employers about hazards: Labor/Management Safety and Health Committees or. "Any other means that ensures communication with employees." The successful operation of Sancon Engineering will depend not only on sales and costs, but also how safely each job is performed. There is no job so important--not any service so-urgent--that we cannot take time to work safely. I consider the safety of our personnel to be above job costs, and I expect your full cooperation in making our program effective. SinceJ3 Ri Helmuth, Project Manager 'I 3 •• EMPLOYEE RESPONSIBILITIES SUPERINTENDENTS: In effectively executing their safety responsibilities, superintendents will: I; Familiarize themselves with the safety program and ensure its effective implementation. 2. Be aware of all safety considerations when introducing a new process, procedure, machine or material to the workplace. 3.., Give maximum support to all programs and committees whose function is to promote safety and health. 4.. Actively participate in safety meetings as required 5. Review serious accidents to ensure that proper reports are completed and appropriate action is taken to prevent repetition. FOREMEN S Our foremen are the foundation of the safety program. Their responsibilities are to: Familiarize themselves with company safety policies, programs and procedures. Provide complete safety training to employees prior to the assignment of duties: Consistently and fairly enforce all company safety rules 4 Investigate injuries to determine cause, then take action to prevent repetition See that all injuries, no matter how minor, are treated immediately and referred to the personnel office to ensure prompt reporting to the insurance carrier. Inspect work areas often to detect unsafe conditions and work practices. Utilize company self-inspection checklists as required. Conduct tailgate safety meetings weekly.. S 5 SAFETY MANAGER The Safety Manager is responsible for the overall execution of company safety policy by: Periodic review of OSHA/CAL-OSHA safety requirements and update of Injury and, Illness PreventiOn Program as required. I. Documentation of employee medical and safety certifications as required by company policy Insuring that field and shop safety inpections are conducted and documented on a . periodic basis. 4. Reviewing and implementing changes in company safety policies 5 Retaining all safety forms per CAL/OSHA requirements and/or company policy 6. Filing of "Employer's Report of Occupational Injury or Illness" form within five (5) - days of any industrial injury. EMPLOYEES 1. All employees have the responsibility to perform their duties in a safe manner, maintain their work area in a safe condition and shall: Follow all instructions and perform his job in accordance with. the safety guidelines as specified in this program. . . Utilize proper judgment in his personal work habits and report to work in a fit condition to meet job obligations. . Be efficient and get things done'-right. Speed does not mean efficiency. Work at a speed consistent with safety. . 1 Be familiar, with the hazards of his job and exercise due caution. Report all accidents immediately to his supervisor and get prompt first aid for all injuries, no matter how minor. . • If involved in an accident, the employee is to cooperate with the Supervisor in explaining what happened and what he thinks caused the accident Report all unsafe conditions without delay to his immediate supervisor. Comply with the Company's policy regarding drugs in the workplace. Avoid 'Practical Jokes,' horseplay and exercise care in avoidance of injury to fellow employees. . . . . 6 .. , J .3 Be familiar with emergency procedures and participate in all emergency drills. Maintain an active interest in the Company Safety Program. Participation in Safety Meetings is mandatory. Observe the "Code of Safe Practices". Set a good example for fellow workmen. Cooperate with supervisors in preventing accidents. 0. Make safety suggestions to his supervisor. Take good care of company equipment and report unsafe or defective equipment to his supervisor Help keep the jobsite and shop areas clean. I . - 7 .-. . . - '-. SAFETY COMMUNICATION In order for our program to be effective in promoting safe practices and procedures, it is imperative that open lines of communication be established between supervisors, employees, subcontractors and the public. As part of the overall communication process, Sancon Engineering will: As appropriate, provide written and/or verbal communications to employees. Provide each new hire with a safety orientation. : C. Encourage employees to advise management when and where a potential safety hazard exists. SYSTEM FOR EMPLOYEES TO INFORM EMPLOYER OF HAZARDS: Encouragement of Employee Reporting The Company encourages and,' indeed, requires all employees to inform management (supervisor, superintendents, Safety Engineer, or other personnel) of any unsafe or hazardous condition when observed or discovered. No Discrimination for Employee Reporting / No employee shall be disciplined or discriminated against for reporting an unsafe condition to management or for correcting an unsafe condition. . . Employees shall report all unsafe conditions to their supervisors or other management personnel when observed or discovered. If an employee sees an employee or supervisor '1 violating the Company's Code of Safe Practices, he should report this to upper management or the Safety Engineer. . . . . SYSTEM FOR IDENTIFYING AND EVALUATING WORKPLACE HAZARDS: When an Imminent hazard exists which cannot be immediately be abated without endangering employee(s) and/or property, remove all exposed personal from the area except those necessary to correct the existing conditions. Employees necessary to correct the hazardous condition shall be providing the necessary safeguards. Periodic workplace inspections to identify unsafe conditionsand work practices shall take place as follows: . • / When the Program is first established. Whenever new substances, processes, procedures Or equipment are introduced to. the work place representing a new safety or health hazard. .• Whenever the employer is "made aware of a new or previously unrecognized hazard". • . - •- . 8 1. • . . . Responsibility: The primary responsibility for hazard identification rests with project foreman. Informal evaluations should be conducted daily. The Superintendent at least quarterly shall conduct a wall-to-wall formal inspection of each phase of project operation. In addition to identifying hazards, he should focus on the adequacy of the assessments done by project foremen. All employees are encouraged to analyze their own job and work area for hazards. If an employee finds possible defects, these should be reported to his supervisor. Hazards shall be corrected if possible, and if not possible, personnel should be removed from the jobsite and hazards isolated. Record Keeping: Each JOBSITE SAFETY INSPECTION REPORT form and each SHOP SAFETY INSPECTION REPORT form shall be maintained for 3 years. Where there are conditions unique to a particular job or operation, which are not covered by the form, additional captions or comments are to be included. ACCIDENT REPORTING REQUIREMENTS Guidelines A written report is to be made promptly for an accident. If an accident occurs in the field, a copy of the "Supervisor's Report of Injury" should be given to the Safety Engineer within 24 hours. Also, if a serious accident occurs in the field, it should be reported immediately by phone. For all accidents that occur in the office, yard or warehouse, the Supervisor will immediately report it to the Safety Engineer or Management. Time Frames for Filing Reports 1. The new Worker's Compensation Reform Act of 1989 requires employers to furnish within one working) day the form "Employee's Claim for Workers' Compensation Benefits." This form must be given to the injured employee (or their dependent) by the Safety Engineer or Supervisor. A completed copy of this form is mailed to the insurance company within 3 days 2. The Safety Engineer is responsible for obtaining all necessary information to complete the form "Employer's Report of Occupational Injury or Illness". California law requires an employer to file this report within 5 days of every industrial injury. ACCIDENT INVESTIGATIONS AND REPORTS •• • It is the policy of Sancon Engineering to carry out a thorough program of accident ivestigatión. Supervisory personnel will be primarily responsible for making an investigation of all accidents in their areas of responsibility. Accidents involving fire, death, serious injury, or extensive property damage will be investigated jointly by the Superintendent, the Foreman and the Personnel Manager. • •• The primary goal of the accident investigation program is the prevention of future similar accidents through the use of knowledge derived from the investigation. Additionally, the investigation will be used to prepare reports required by Federal and State law as well as the Worker's Compensation Insurance Carrier. These reports are critical in establishing the Company's and the Supervisor's liability under the law. When an employee is injured at work, the supervisor is responsible for taking emergency action to have first aid administered, to obtain professional medical attention as soon as possible and protect other employees and equipment. The supervisor must then begin to investigate the circumstances of the accident. The following procedures have been found to be effective when investigating accidents: GO to the scene of the accident at once. TALK with the injured person, if possible. Talk to witnesses. Stress getting the facts, not placing blame or responsibility. Ask open-ended questions. LISTEN for èlues in the conversations around you. Unsolicited comments often have merit. ENCOURAGE people to give their ideas for preventing a similar accident. STUDY possible causes - unsafe conditions and/or unsafe practices. CONFER with interested persons about possible solutions. 7. - WRITE your accident report giving a complete, accurate account of the accident. FOLLOW-UP to make sure conditions are corrected. If they cannot be corrected immediately, report this to your supervisor. PUBLICIZE corrective action taken so that all may benefit from the experience. In order for the Supervisor's RepOrt' to be effective, it should contain, as ,a minimum, .a detailed answer to the following questions: What Was the Employee Doing? - Explain in detail the activity of the employee at the time of the accident. What Happened? - Indicate in detail what took place, describe the accident, the type of injury, the part' or parts of the body affected and whether the employee was wearing appropriate safety equipment. • 0 What Caused the Accident? - Explain in detail the condition, act, malfunction, etc., 0 0 • that caused the accident. Remember that it is possible to have more than one reason or cause for an accident. 0 0 4 What Can Be Done to Prevent a Similar Accident? - Indicate corrective action to prevent recurrence. 10 ' SAFETY INSPECTIONS Company Inspections The Company requires inspections at new jobsites, whenever new substances, processes, equipment, or procedures are instituted or whenever new hazards are noticed. We also make periodic inspections of the general work areas and specific workstations. General inspection requirements are the responsibility of the Safety Manager. He shall insure that field and shop inspections are conducted on a routine and periodic basis. Reports of these inspections shall be maintained. - Employers are required to keep records of all scheduled and periodic inspections. These records will include: The name of the person conducting the inspection; Record of all unsafe conditions and/or practices identified; and The action taken to correct the unsafe condition and practice. Each Job site safety inspection report and shop safety inspection 'report shall be maintained for 3 years. Foreman Inspections Foreman are responsible for making daily inspections of the work areas, machinery, equipment, work practices and job sites of the employees under their authority. All non- 'compliance with the Company's Code of Safe Practices is to be corrected immediately. In the case of hazardous machinery or equipment, maintenance should be called. The machine shall remain shut down until it has been cleared for use by maintenance. ' Employee Inspections Employees are responsible for inspecting their work area and machinery for unsafe or hazardous conditions. Employees should immediately correct all unsafe conditions and report them to their supervisor, superintendent or other management personnel. If the supervisor fails to act upon a safety complaint, the employee should bring the matter to the attention of upper management or the Safety Superintendent. Employees may make anonymous reports. No employee shall be disciplined or otherwise discriminated against for reporting or correcting an unsafe condition Maintenance Inspections - - Maintenance employees will, as a matter of course, be vigilant to the safety considerations of any machine or equipment they are called upon to repair. Special Inspections In the event of an accident, illness or injury during work or at the Company's premises, the Safety 11 •- '- Engineer, jobsite Supervisor or other management representative shall make a complete S investigation of the incident and inspect the area or equipment involved. A report of the investigation and inspection shall be made. JOB SITE SAFETY INSPECTION REPORT INSPECTION CONDUCTED BY___________________________________ DATE LOCATION____________________________ Are All Employees Aware of Sancon's Safety Ru1es'and Procedures and received a copy? Yes ( ) No ( ) Explain__________________________________________________ Are Employees Using the Required Safety Equipment? Yes ( ) No ( ) Explain____________________________________________________ Are Safety Equipment Kept in Good Condition? Yes ( ) No ( ) Explain______________________________________________ Are Employees Wearing the Required Foot Wear and Clothing? Yes ( ) No ( ) Explain - Are Personal Respirators on Hand, Clean and in Good Condition? I Yes ( ) No ( ) Explain S Are Confined Space Rules and Permit Forms Followed and Used? - Yes ( ) No ( ) Explain____________________________________________________ 7: Is Truck Equipment Kept Organized and Readily Available? Yes ( ) No ( ) Explain__________________________________________________ Are Work Areas Kept Clean and Organized? Yes ( ) No ( ) Explain____________________________________________________ Are Hazardous Materials Being Properly Stored and Labeled? Yes ( ) No ( ) Explain____________________________________________________ Are Hazardous Materials Being Used Properly? Yes ( ) No ( ) Explain____________________________________________________ Are Hazardous Waste Being Disposed of Properly? - Yes ( ) No ( ) Explain - '. 12. Are Flammable Waste Being Stored Properly? S - Yes ( ) No( ) Explain Are Electrical Wiring and Equipment Being Used Properly? Yes ( ) No ( ) Explain____________________________________________________ Are Mechanical Devices Properly Guarded with All Required Safety Features? Yes ( ) No ( ) Explain____________________________________________________ 12 - (.. Are Truck Cranes in Good Working order? Yes ( ) No ( ) Explain_________________________________________________________ Are Truck Cranes Operated Safely? Yes ( ) No ( ) Explain____________________________________________________ Are Required Safety Signs Properly Displayed? Yes ( ) No ( ) Explain______________________________________________________ Are MSDS Sheets Properly Kept for All Chemicals? Yes ( ) No ( ) Explain____________________________________________________ Are First Aid Kits Properly Equipped and Available? Yes ( ) No ( ) Explain____________________________________________________ Observed hazards and unsafe act or procedures. Item # Priority Unsafe Conditions Corrective Action Completion Date -I 13 T SHOP SAFETY INSPECTION REPORT INSPECTION CONDUCTED BY'___________________________________ DATE LOCATION___________________________ 1. Are All Employees Aware of Sancon's Safety Rules and Procedures and Received a Copy? Yes ( ) No ( ) Explain__________________________________________________ '.. 2. Are Employees Wearing the Required Foot Wear. and Clothing? Yes ( ) No ( ) Explain__________________________________________________ Are Eye Protection, Face Shields, Ear Protection and Protective Gloves Used? Yes ( ) No Explain__________________________________________________ Are work Areas Kept Clean and Organized? - Yes ( ) No( ) Explain__________________________________________________ Are Floors Kept Clean and Dry? Yes (-) No ( ) Explain__________________________________________________ Are Tools and Equipment Put Away Each Day? - Yes ( ) No ( ) Explain__________________________________________________ - Are Hazardous Materials Being Properly Stored and Labeled : Yes ( ) No ( ) Explain__________________________________________________ 8 Are Hazardous Materials Being Properly Used? Yes ( ) No ( ) Explain__________________________________________________ Are Hazardous Wastes Being Stored and Identified Properly? Yes ( ) No ( ) Explain__________________________________________________ Are Hazardous Waste Being Disposed of Properly? Yes ( ) No ( ) Explain__________________________________________________ Are Flammable Materials Properly Stored and Labeled? Yes ( ) No ( ) Explain____________________________________________________ Are Flammable Waste Being Stored Properly? Yes ( ) No ( ) Explain____________________________________________________ Are Electrical Wiring and Equipment Being Used Properly? - Yes ( ) No ( ) Explain 1 Are Mechanical Devices Properly Guarded with All Required Safety Features? - Yes ( ) No ( ) Explain_______________________________________________________ Are Compressed Gas Cylinders Secured and Properly Stored? Yes ( ) No ( ) Explain 14 .- Are Forklifts in Good working order? Yes ( ) No ( ) Explain__________________________________________________ ' Are Forklifts Operated Safely? Yes ( ) No ( ) Explain__________________________________________________ Are Lockout/Tagout On Defective Equipment Being Used? Yes ( ) No ( ) Explain - 19; Are Emergency Eye Wash Stations in Operating Condition? Yes ( ) No () Ex lain Are Required Safety Signs Properly Displayed? Yes ( ) No () Explain__________________________________________________ Are MSDS Sheets Properly Kept for All Chemicals? Yes ( ) No () Explain____________________________________________________ Are First Aid Kits Properly Equipped and Available? Yes ( ) No() Explain______________________________________ Are Required Fire Extinguishers in Place and Properly Serviced? Yes ( ) No () Explain • Observed hazards and unsafe act or procedures • Item #_ Priority Unsafe Conditions Corrective Action Completion Date I / 'CODES OF SAFE.WORK PRACTICES (GENERAL SAFETY RULES) For the protection and safety of all employees, Sancon Engineering has established the following rules designed to prevent accidents and injuries. Compliance with these rules is mandatory. Documentation will be made when the rules are distributed to new employees. Proper footwear and clothing will be worn at all time (steel toe boots, long pants, shirt and safety glasses). Hard-hats where required. Do not wear loose clothing, jewelry or keep long hair in a down position where there is a danger of catching such articles in moving machinery. Horseplay, running, fighting or any activity that may result in injury will not be tolerated. Eye protection is required at all times. 5 Operate machinery with all guards in place. Tampering with safety devices is cause for immediate disciplinary action. Do not operate any machinery you are not.familiar with. Machines must never be cleaned, adjusted or repaired until after the machine is turned off, the circuit brOken at the power source (including lock-out) and warning tag is placed at the controls. Any defects in materials, machinery, tools and equipment must be reported immediately to a supervisor. Do not leave tools, materials or other objects on the floor, which might cause others to trip and fall. Do not block exits, fire doors, aisles, fire extinguishers, gas meters, electrical panels or traffic lanes. Avoid risk of rupture, internal injury or back injury in attempting to lift or push excessive loads. If an object is too heavy to move without strain--ASK FOR HELP. Observe the correct position for lifting. Stand with your feet slightly apart, assume a squatting position with knees bent and tuck your chin. Tilt head forward, grasp the load with both hands and gradually push up with your legs, keeping your back straight and avoiding any abrupt movement. Do not distract others while working. When approaching a machine operator for any purpose, do so from the front or side in a way that he or she will see you coming and will not be shocked or surprised. If conversation is necessary, make sure the machine is turned off. Do not allow oil, wax, water, or any other material to remain on the floor where you or others may slip. Report any spills to your supervisor. 16 / 15. When handling hazardous materials insure you follow prescribed safety procedures and use required safety equipment. When using secondary conditions filled by others, insure that they are labeled as to their contents and hazards. 16. Use appropriate gloves when' handling materials with sharp or jagged edges, which may result in lacerations. 17. 'Do not attempt to operate machinery for which you are not trained. 18. Unnecessary and excessive haste is the cause of many accidents. Exercise caution at all times' WALK, DO NOT RUN! 19. The use of hot production equipment or materials for the purpose of cooking or heating food is strictly prohibited. 20. All work related injuries and accidents, no matter how minor, must be reported immediately to your supervisor. It is imperative that all employees become thoroughly familiar with the above' safety rules. Failure to comply with safety rules or procedures, or failure to wear the appropriate safety equipment, will result in disciplinary action up to and including termination. CODES OF SAFE WORK PRACTICES (SPECIFIC SAFETY RULES) Housekeeping A high percentage of accidents are due to poor housekeeping practices. Periodic cleanups are not sufficient. Housekeeping is a continuous process. Some important elements of housekeeping are: Keep floors, stairways and landings, passageways and work areas clean of any obstructions that could create a fire or safety hazard. • Keep exits clear at all times. • 3. Allow sufficient clearance around mechanical equipment, H\TAC equipment and electrical panels. After use, materials, tools and equipment should be stored in their proper place. Remove and deposit scrap and debris in the proper containers. Do not overfill.. Store oily waste or rags and other flammable materials only in metal,-'receptacles provided for that purpose. Clean up oil, grease or any other type of spill immediately!! 8 Bend down nails in pieces of wood Preventing Falls • ' It is estimated that one out of every five disabling injuries is a result of a fall from either the same level or higher elevations. To prevent falls on the same level: • F. Avoid wet floors, oily floors, improperly placed, or. damaged floor coverings. Immediately clean up spills to prevent slippage. •. • • • • 17 / •• • 4. 2. Avoid congestion and keep doors clear of unnecessary material. 3. Ensure that your footwear provides good traction. 4. Watch for differences in floor elevation. 5. Use handrails where provided and avoid rushing. To prevent falls from high levels: I. Utilize approved conventional fall protection systems where practical for the work Always use a suitable ladder or step stool when climbing and avoid overreaching. Avoid standing on makeshift elevated platforms like boards between ladders, saw horses, worktables, carts and the like. Use caution when working on elevated platforms which have not been provided with guardrails. If no guard rails are present, an approved fall arrest system shall be utilized. / 5. Never use the forklift or lift truck to reach overhead unless using a man lift. 6. Never ride a forklift or lift truck. These vehicles were designed to accommodate the driver only. 7. Avoid jumping down from an elevation of more than four feet. 8. Utilize caution tape or personnel barriers/barricades as necessary to help designate potential fall/trip locations 9. For work along platform/tank edges, work shall utilize scaffolding from within the tank to access the upper edge. For work that cannot be performed using scaffolding, workers shall be tied off to an approved fall arrest system. ALERT YOUR SUPERVISOR TO ANY CONDITION THAT COULD RESULT IN A FALL! Hand Tool Safety Hand tools are safety devices, provided they are the correct tool for the job to be done and they are in good working condition. Defective tools and those used improperly can be extremely dangerous. For example: Slipping wrenches can cause falls from ladders: Loose handles on hammers and picks can cause serious head injuries People have lost eyes by using drills and chisels with mushroom heads. The following simple guidelines can contribute to the prevention of injuries involving hand tools: Use only tools that are designed for the job and are in good condition. Do not use a wrench in place of a hammer or a screwdriver as a chisel. Do not use splintered, broken, rough or loose tools. Replace them. Tools used for working around electricity must have insulated handles. Impact tools such as hammers, chisels, star drill pins and the like should be kept free of mushrooms. Do not use files without handles or wrenches without spread jaws. Make sure the jaws of all wrenches are adjusted tightly, before putting strain on the 18 . wrench. Use correct size open end or box end wrench. Do not use an adjustable wrench to loosen or tighten nuts. Sharp edged or pointed tools should be stored in a safe place. Do not carry sharp tools in your pockets. Use a tool belt if you do not have a tool chest. Use appropriate personal protective equipment, which was specifically designed for the job. Double check all tools before using them. Never use a defective tool.... turn it in! Power Tool Safety Power tools, whether powered by electricity, gasoline or air, require considerable skill and complete attention on the part of the user. The following guidelines can make working with power tools safer: It is imperative that the correct tool is used for the job it was intended and that it is used correctly. Keep tools in good working condition. Damaged or defective tools should not be used until restored to full operating condition. 0 Do not use tools until you are completely familiar with the operating instructions. Never operate tools without the guards. Inspect electrical cords or airlines for damage prior to use. Prior to setting a tool down, make sure the power is off and the motion has shopped. Disconnect the tool from the power source before changing drills, blades or bits or attempting any type of repair or adjustment.- Take special precautions when using powered tools while on a scaffold or other location with limited footing. Get a good footing, use both hands, keep cords clear of obstructions, do not overreach. A dull blade on a power saw has a higher tendency to "kick" back on the operator than one with a sharp blade. Machinery and Equipment The following simple guideline will contribute to preventing accidents involving machinery and equipment. Prior to operating any piece of machinery or equipment, complete instructions and permission must be obtained from the appropriate supervisor. Make sure all guards are in place before starting a job. Guards are in place for your protection and should never be bypassed or removed. Keep fingers out of the way of cutting edges and other exposed moving parts. Use a brush, special tool or hook to remove chips, shavings or other material from wok areas. Do not use your hands. Do not try to brake or slow down moving machinery with your hand or a makeshift 0 device. 0 • • Rings, bracelets, watches, loose garments or neckties are not to be worn when operating machinery or equipment. 0 - Safety glasses and/or approved eye protection is to be worn as prescribed, in all designated areas. • • 19 • Before cleaning, oiling or adjusting the moving parts of a machine, make sure it is completely shut down. S A lock-out on the power switch must be used while performing any maintenance work on machinery or equipment. Make sure any guards, which may have been removed during maintenance, are replaced. Fork Lifts - Forklifts shall be used only in a safe manner. Visibility is poor, therefore, slow speed should be the normal operation. Turning at rear wheels requires care to prevent injury to workers off the vehicle. Forks must be placed on the ground at end of use to prevent someone from walking into raised forks. EXTREME CARE MUST BE TAKEN WHEN MOVING TRAILERS TO PREVENT DAMAGE TO TRAILER HITCH. Air Compressors - Air compressors can injure hearing unless earplugs are used. Compressed air can puncture skin and can cause injury by flying debris. Always wear eye protection and do not disconnect air lines under pressure. Sandblaster - The blast from sandblast equipment can injure skin, eyes and hearing. All persons within 50 feet of sandblasting shall wear ear and eye protection. Sandblast operator shall wear full head air support helmet, long length gloves, and coveralls. Care must be taken in using only good quality, non-damaged hose. DO NOT DISCONNECT AIR LINES UNDER PRESSURE. Water Blasting - Extreme care must be used when operating the blaster. Safety equipment such as steel-toe boots, face shields, and heavy gloves shall be used. The jet from the nozzle can cause injuries similar to a shotgun blast. Changing of tips, guns or hoses shall only be done vith the blaster engine turned off. Care shall be taken, in handling the gun and hoses so as not to damage the protective integrity of the system. Damaged or worn hoses or guns shall be set aside and replaced with safe components. Any and all injuries caused from the water jet shall be immediately treated by a doctor. The first aid and hospital treatment procedures form should be taken along with the injured individual to the' hospital. This form shall be posted on the water blaster and removed when needed. ' High Pressure Airless Spray Equipment - Airless spray equipment is dangerous and must be operated with caution. High pressure can cause liquids to penetrate the skin causing chemicals to be injected into,, the body. The spray blast can cause blindness if directed at the eyes. Safety glasses and protective gloves shall be worn at all times when operating or performing maintenance or repairs to the equipment. Pumps must be disconnected and pressure relieved from the lines before disconnection of hoses or spray gun can be made. Any injuries which occur from the airless stream must be immediately treated by a doctor. ' Hoses, connections and gauges, which become faulty or worn must bereported to a responsible safety person. Ladder Safety Statistics show that a tremendous number of disabling injuries occur as a result of falls from ladders. These accidents are basically caused by: , 20 ' I . Use of unsafe ladders; or 2. Unsafe use of ladders. The following guidelines will help reduce the possibility of ladder falls. 1. Always use a ladder when you have to climb. 2. Set the base of the ladder a distance ofone-fourth of its length from the support. If necessary, the ladder should be blocked at the base and tied-off at the top. 3: Make sure that straight or extension ladders are equipped with the proper type of safety feet. '4. Always face the ladder when going up and down. Look up to check for restrictions or objects on which you might bump your head. Never lean sideways or overreach while working from a ladder. Do not use stepladders as straight ladders. Always open the stepladder and A-type ladder fully so that the spreader is fully extended. Electrical Safety These simple guidelines will help reduce the possibility of accidents. Ground all portable electric hand tools by using, a three-prong plug unless the tools are of the double insulated type. Inspect all extension cords for broken insulation. Keep them in good repair. Do not use metal ladders near electrical installations or whn working on electrical equipment. Check droplights before use. Make sure there are no breaks in the insulation, ascertain that it is properly grounded and that the plug, socket, and lamp. guard are in good condition. Ensure that electrical testing and repair equipment are in good operating condition. De-energize all circuits before working on lines.. Under certain conditions, low voltages can kill. Lock out and tag out circuits when repairs are being made. This way.others cannot re-energize them. " Ensure that there are no exposed wires, switches, junction boxes or control panels. Avoid using extension cords or overloading circuits. . Inform the job site superintendent immediately if you see electrical problems. Back Safety • . . An estimated 8 out of every 10 Americans will suffer a back injury during their lifetime. Of the 2.2 million injuries incurred on the job each year, 30% are back injuries. Protecting your back round-the-clock is your best insurance against back injury. To do this, you should: • • , .. • 1 Start with conditioning - Learn to reduce stress Additionally, a sensible diet in combination with a good exercise program will contribute to a healthier back. .2. Think before your lift.' . . .. •' • . • 21 • • Size up the load. If it is too heavy or bulky, get help. You may be able to find a better way by using a forklift or hand truck. C. If you must lift, make sure you have a clear path to your final destination. d. Arrange the workplace so that you or other workers don't have to repeatedly handle heavy loads or lift objects from the floor level. 3. Learn to lift properly: Get a firm footing Bend your knees. - C. Tighten your stomach muscles. Lift with your legs. Keep the load close to your body. Keep your back upright. Other safety guidelines are: Do not arch your back or twist during a lift. - Push instead of pull when handling carts. Elevate one foot when standing for long periods of time. Adjust your car seat so that knees are bent and your back is straight. If possible, split up the load. Take time to be safe. Material Handling and Lifting Almost 25% of all disabling injuries are the result of material handling accidents. You should: Use your head - check the load - check your path! Do not lift heavy or hard to handle materials by yourself. Get additional help or use a crane, hoist, or other lifting equipment. Lift operators and riggers must comply with the appropriate approved operator's manual. Check your path for obstacles and tripping hazards. Inspect the object you are going to lift. Make sure there are no sharp corners, nails, or other things that may cause an injury. Make a trial lift of the object to determine if you can handle the lift without strain. Firmly set your feet, somewhat apart, crouch as close to the load 1 as possible. Do not get into a full squat but bend your legs. Keep your back straight. Bend at the hips so you are centered over the load. The object is to do the work with your leg muscles and not with the weaker back muscles. Get a firm grip on the object by placing your hands on diagonal corners. If necessary, lift one end slightly to get a hand under it. To lift, straighten your legs and swing your back into a vertical position. In setting objects down, bend your legs and the trunk of your body at the waist. This will make your leg muscles and not your back muscles do the work. Keeping the legs straight and arching the back to set something down can result in injuring your back. Care should be taken when packing or unpacking boxes. Projecting nails in boxes, boards or barrels should be bent over or removed. Eliminate all other sharp - projections. 0 22 Cranes and Hoists Guidelines include: Only designated operators authorized by the superintendent/ supervisor are allowed to operate cranes. Lifting hardware, lines and runways should be visually checked prior to each use. Never swing loads over the heads of workers. Tag lines should be used to control loads when warranted. Never exceed the rated load capacity. 6 Check loads Just off the ground for stability before hoisting Never leave a suspended load unattended without securing it. Never allow loads, booms or rigging within 25 feet of energized electrical lines unless the lines are de-energized. Cranes and hoists should not be left unattended unless the motor is stopped and controls are in the OFF position. ,. Welding and Burning Only qualified individuals, familiar with the use of gas and' electric' welding 'equipment should be allowed to operate it. Before starting any welding or burning work, operators should take the following precautions: Ensure that cutting and welding equipment is in good operating condition. Ensure that the work area is clear of flammable or combustible materials. Ensure that combustible structures are shielded with 'flame-proof screens. • 4 Ensure that suitable fire extinguishers are readily available 5., Ensure that proper ventilation is provided particularly in confined space. • 6. • Ensure that welding flashes are shielded. . • '' ; • • Ensure that all parts subject to electrical current are fully insulated. • • Ensure that the ground return cable has a safe current carrying capacity equal to, or 23 exceeding, the specified maximum output capacity of the arc-welding unit it services. Ensure that proper personal protection is used including face shields, goggles, hand shields and protective clothing. Ensure that welding gas cylinders are properly stored. VEHICLE SAFETY All employees authorized to drive company vehicles, for any purpose must possess a valid California driver's license and have a driving record which is acceptable to the company's insurance carrier. Employees hired or placed into positions requiring the use of company vehicles will have their Department of Motor Vehicles (DMA) records checked by the company's insurance carrier at the time of employment or placement into these positions, and then regularly thereafter through direct notification from the DMV utilizing the Employee Pull Notice Program. Employees in these positions who are uninsurable or who become uninsurable (based on the standards of the insurance carrier) due to an unsatisfactory DMV record or whose driver's license are suspended- or revoked will normally be subject to disciplinary action, up to and including possible termination. Medical form for employee requiring a class 'A' or 'B' license will be retained on file. The responsible person of vehicle and equipment in tow is the driver. Drivers shall insure that his vehicle is safe for operation by inspecting the following before driving. Tires properly inflated Windshield and mirror clean and adjusted Load secured from shifting or falling off the truck The vehicle hitch secure and safety chain attached Running lights and trailer lights operational Truck and trailer surge brake operating safely Care must be taken while driving loaded trucks by allowing additional distance for stopping. When backing with trailers caution should include the avoidance of jackknife by allowing plenty of turn around space. Any employee under the influence of ANY drug or alcoholic beverage must not operate any vehicle. Personal use of company vehicles for any purpose whatsoever, is strictly forbidden without the expressed prior approval of management. Any mechanical defects should be reported to your supervisor for appropriate action prior to operation of a vehicle. You must immediately report to your supervisor any accident and any moving or non- moving violation you are cited for while driving a company vehicle. All employees operating company vehicles off premises, or their own vehicles on company business, are required to obey all traffic regulations. 24 DISCIPLINARY PROCEDURES Employees who fail to comply with safety rules will be subject to disciplinary action up to and including termination. Supervisors will follow the normal disciplinary procedures as follows: 1: Verbal counseling - the first step. Must be documented in the employee's personnel file. Written warning -outlining nature of offense and necessary corrective action. Suspension without pay - the third step or a separate disciplinary action resulting from a serious violation. 4. Termination - if an employee is to be terminated, specific disciplinary action resulting from a serious violation. Supervisors will be subject to disciplinary action for the following reasons: 1. Repeated safety rule violation by their department employees. 2; Failure to provide adequate training to employees priorto job assignment. 3 Failure to report accidents and provide medical attention to employees injured at work 4. Failure to maintain good housekeeping standards and cleanliness in their department. 5 Failure to control unsafe conditions or work practices Supervisors who fail to maintain high standards of safety within their department will be demoted or terminated after three documented warnings have been levied during any calendar year. TRAINING AND INSTRUCTION : • The goal of our safety-training program is to develop safe work habits and attitudes. It is critical that new workers understand work rules and procedures prior to being assigned a job. This training also includes supervisor, job foreman training and periodic supervisor/management meetings The Safety Manager is responsible for providing safety training to their department employees utilizing the Job Instruction Training (JIT) method described below. This Program must provide training and instruction: I When first established. To all new employees. • •• To all employees given new job assignments for which training was not previously received 4. Whenever new substances are introduced to the work place that represent a new •: hazard or whenever the employer is "made aware of a1 new or previously 25 • 7 •• •• •• unrecognized hazard". 5. For all supervisors to familiarize them with the safety and health hazards to which employees under their immediate direction may be exposed. HOW TO GET READY TO INSTRUCT Have a Timetable How much skill you expect them to have, by what date. Break Down the Job List important steps, pick out the key points. (Safety is always a key point) Have Everything Ready The right equipment, materials and supplies. • Have the Workplace Properly Arrangd Just as the worker will be expected to keep it JOB INSTRUCTION TRAINING (JIT) HOW TO INSTRUCT 1. Prepare - Put the worker at ease. Define the job and find out what is already - known about it. Get the person interested in learning the job. Place in correct position. Present - Tell, show, and illustrate one IMPORTANT 'STEP at a' time. Try Out Performance - Have person do the job-correct errors. Have person explain each key point to you as the job is done again. Make sure' the person understands. '\ ' Continue until YOU know the person knows. 4. Follow-Up - Put them on their own. Designate to whom 'to go for help. Check ' frequently. Encourage questions. Taper off extra coaching and close follow up. Safety is always a key point. The fundamentals of safety practices will be reviewed prior to a new employee's first job assignment. Our safety orientation checklist will be utilized to document this training. EACH INDIVIDUAL EMPLOYEE NEEDS TO KNOW AND UNDERSTAND THE FOLLOWING: ' • No employee is expected to undertake ajob until he has received instructions on how to do it properly and has been authorized to perform that job. No employee should undertake a job that appears to be 'unsafe or use chemicals 26 1• without understanding their toxic properties. Mechanical safeguards must be in place and must stay in place. Each employee is expected to report all unsafe conditions encountered during work. Any injury or illness suffered by an employee, even a slight one, must be reported at once.' The Company has a safety and health program in place, and the Company is willing to keep improving the program Safety Training Needs to Be an On-Going Process At a minimum, documentation shall consist of the date of the training, the project identification, the name of the individuals being trained, the name of the trainer, and a summary of the training provided. 'To the greatest extent possible, the safety incentive program should reinforce any training provided. TAILGATE SAFETY TALKS FOR CONSTRUCTION Introduction Brief safety talks performed by the supervisor or job foreman with the job employees, on a regular basis, are essential in maintaining a high level of safety awareness. This is particularly true of the construction trades because of their high rate of injuries. For the construction trades CAL/OSHA requires "tailgate" safety meetings to be held at least every ten working days. Read the talks to yourself before the meeting and think about the important points. When giving the talk, put the ideas into your own words, if you can. otherwise read but try not to • sound to mechanical. In any case, try to relate to the topic to the specific job they happen to be working on. Involve the crew in the discussion to keep it lively and interesting.- Same other tips to make the talk more effective: Don't have them on the employees' own time. Make them brief-- 5 to 10 minutes. • 3 Keep it focused on one subject 4. If possible, demonstrate an object. Hold it up or have the crew gather around it. Each contractor is urged to give "tailgate" safety talks on all of the hazards peculiar to their operations. 27 ° HAZARDOUS ENERGY CONTROL PROGRAM (LOCKOUT TAG-OUT PROCEDURES) Policy Fl Equipment should be properly and uniformly locked out and tagged whenever it is down for any reason, in order to protect the exposed employees from inadvertent equipment operation and potential harm. C Purpose The purpose of this section is to provide a safe method for rendering inactive any electrical equipment or operating systems (including mechanical or piping) when equipment Cis down for any reason, such as repair, removal or replacement. This procedure is provided in an effort to identify certain LOTO procedural elements. The Subcontractor's or other Agency's program may not exactly follow this procedure; however, 'the basic elements shall be available to protect all employees from the potential hazards A JSA is required and must be - 'reviewed and accepted by the Sancon Safety Manager prior to the start of work. Responsibilities When needed, the Subcontractor or other Agencies are responsible to assure that a LOTO procedure is put in place in their area of work. The Project Manager is responsible to ensure that all construction employees are trained and familiar with and use the procedure wherever it applies. All employees are responsible to be aware that a LOTO Program is in effect and the specifics of the Subcontractor's or other Agency's program. Anyone who may be exposed to the sudden release of çnergy or materials will be familiar with and abide by the established LOTO procedure. . If an employee observes a safety problem, he/she will notify their Supervisor, the Subcontractor or other Agency responsible for the area safety. Implementation A LOTO procedure should include five basic phases of work on any system: (1) shutting down equipment, (2) Verify energy is released (3) repairing or installing equipment, (4) Removal of LOTO devices (5) startup of equipment. It is 'likely that some situations will not include all three phases as such; however, regardless of the operation and the phase or phases involved, the "lockout/tag-out" clearance procedure must be observed to assure the safety of the operation. Even though this procedure generally provides for locking and tagging oequipment, the 11 danger tag alone is to be considered and inviolable device and any equipment bearing such a tag must not be operated under any circumstances. Also, locks must be used in conjunction with a tag to afford maximum personnel protection. Prior to starting any major operation, which would involve these locking and tagging 28 • • procedures, a meeting shall be set up by the supervision, employees and inspectors involved. The project's safety personnel shall attend this meeting. A specific procedure will be adopted and reviewed by all concerned with the operation, prior to commencement of work. Materials and Hardware Sancon shall provide accidental prevention signs, tags, padlocks, seals or other similarly effective means, which may be required for cleaning, servicing, adjusting, repair work or setting-up operations. Signs, tags, padlocks, and seals shall have means by which they can be readily secured to the controls. Tagout device attachment means shall in a non-reusable type, attached by hand, self-locking, and non-releasable with a minimum unlocking strength of no less than 50 pounds. Shutdown and Repair of Equipment or Systems All personnel, before working on equipment should assure that: Others are not working on the piece or system, and if others are working on it, that this procedure will not endanger any personnel or the equipment. Equipment is not under pressure, energized, at elevated temperature or otherwise unsafe to be worked upon. Others adjacent to the work area are not endangered. Before starting work, the supervisor shall contact the designated supervisor (responsible for the equipment or system). This supervisor will show him the devices that require tagging; i.e., switches, starters, valves, lockout controls, etc. This will be accomplished by using an approved danger tag and lock. The main disconnect shall be opened in addition to any remote control switches. On electrical work, it is advisable as a further precaution for the electrician to remove the supply fuses. On piped systems, the main valves shall be closed and pressure relieved. The supervisor shall make sure that the equipment or system is inoperative. After assuring himself that the equipment has been properly shut down in accordance with the procedures described above, the supervisor and employees involved in the. work shall positively, determine that the equipment or system has been locked and tagged. Each employee will place his/her own tag and lock on the switch or valve. A distinctive danger tag and lock (when possible) will be attached to each device: This tag shall be dated and signed by the individuals doing the work. A short explanation of the reason for the fag hould appear in the provided spaces. Only. authorized personnel will repair specific equipment with system danger tags. • If mechanically possible, a padlock (to which only the employee placing the lock shall have access to keys) shall be placed on equipment in such a manner as to render operation of the . equipment impossible. • • . •• • Starting Up Equipment or Systems • • •• • 29 • • • • As soon as the work is completed, the danger tags and locks shall be removed pnly by the individuals installing them. - In the event the shift ends before the work is completed, the status of the work is to be reported in detail to the oncoming shift personnel and the tags and locks on the system replaced by the oncoming shift personnel. Upon completion of the work, Sancon, the Subcontractor or Agency supervisor will make certain all tags and locks have been removed and personnel are clear of the equipment or system. The equipment will be returned to normal operating conditions. General In an emergency, or if the person who placed the tag and lock is not available the Lock and Tag Removal Procedure established by Sancon, the Subcontractor's or other Agency's LOTO procedure will be implemented. Inspection An independent annual periodic review/inspection of authorized employees will be conducted to ensure that they are implementing LOTO procedures properly and that they are familiar with their responsibilities under those procedures. The periodic reviews/inspections are intended to identify and correct any deviations observed. An independent authorized employee will perform the periodic reviews/inspections. The work of all authorized employees will be reviewed/inspected by another authorized employee each calendar year. Subcontractors and Host Employers Whenever outside servicing personnel (sub-contractors) are to be engaged in activities covered by this section, the employer's lockout or tagout procedures shall be followed. When working for Host Employers, Sancon will be using their Hazardous Energy Control Program if applicable. Training All authorized employees will receive the Initial Control of Hazardous Energy course. A refresher C9ntrol of Hazardous Energy course will be provided annually for those employees whose job duties require them to continue to perform as an authorized employee. Initial training will include the following topics: Recognition of hazardous energy sources The type and magnitude of energy at the District • Methods for isolation and control of the energy Lockout/tagout procedures •. The difference between lockout and tagout Application of Red Tags - • Limitations of tags as energy control devices The requirements of Title 8, Section 3314, Cleaning, Repairing,Servicing and Adjusting Prime Movers, Machinery and Equipment Refresher training will be conducted annually by the Safety Division on topics related to Control of Hazardous Energy. Records of Training Authorized employee training records include employee name, instructor name, and training date. The records for affected employees include the employee's name, safety meeting date, and instructor. Employee training records are maintained in the Sancon Master Training Record and keep on record for five years. -I / 31 • M -S CONFINED SPACE ENTRY PROGRAM PREFACE: Many of Sancon Engineering's jobs are spaces that are considered "confined" because the configuration of the spaces hinders the work activities of employees who must enter, work in, and then exit these spaces. A confined space is legally defined as a space that meets the following definition: - Is large enough and so configured that an employee can bodily enter and perform assigned work; Has limited or restricted means for entry and exit; and, is not designed for continuous employee occupancy. Recogiize that for a space to be identified as a confined space, it must meet all three of these criteria. - The Federal Occupational Safety and Health Administration (OSHA), Department of Labor, published Standard 29 CFR, Section 1910.146 - Permit-Required Confined Spaces to protect workers who must enter these spaces in the performance of their work activities. The California Division of Occupational Safety and Health (Cal-OSHA), Department of Industrial Relations, published Title 8, General Industry Safety Orders, Section 5157 - Permit-Required Confined Spaces as a standard to protect workers from the inherent hazards associated with confined space entry as well. ( The OSHA Standard, which mandates certain performance based criteria for Permit- Required Confined Space entry, requires employers to establish a Permit-Required Confined Space Program; furthermore, the standard requires employees to abide by the policies, practices, procedures, and rules governing the established Permit- Required Confined Space Program. S AUTHORITY ) Sancon is committed to providing'a safe and healthful work environment for all employees. The Permit-Required Confined Space (PRCS) program is a critical element in the success of the Sancon's overall safety program. Whild the exact number of annual deaths and injuries related to PRCS entry is unknown, industry experience bears proof that failure to comply with and follow PRCS policies and procedures may result in serious and/or fatal accidents. Compliance with PRCS policy and procedures is crucial to the safety of Sancon's employees and contractors. The importance of following the PRCS program must be understood by all employees charged with the responsibility of working in and around permit-required confined spaces. Sancon's PRCS program has been developed to provide our employees and contractors with safe methods for working in and around permit-required confined spaces. S . APPLICATION Sancon's PRCS program is concerned with the protection of. employees whose job responsibilities require them to work in and around confined spaces. The hazards encountered andassociated with entering and working in confined spaces are capable of causing serious injury to workers. To effectively protect our employees and manage confined space hazards, the following must occur: 32 . • Continue to develop the knowledge, skills and abilities of affected staff to recognize the diverse nature of existing or potential confined space hazards and methods available to eliminate or control those hazards. Ensure the development and use of appropriate confined space entry procedures. Develop appropriate 'methods to manage our contractors to ensure they are protecting their employees and not putting Sancon's personnel at risk. Ensure the proper implementation of the PRCS program. Sancon has developed the PRCS program in accordance with Cal/OSHks Permit-Required Confined Space standard (8CCR, Section 5157) and best industry practice. The application of the required practices and procedures to protect employees from the hazards of entry into permit- required confined spaced has also been included in the program. GENERAL REQUIREMENTS: CONFINED SPACE CLASSIFICATION A critical element of a confined space program is a mechanism for classification and evaluation of a suspect confined space area. During the initial evaluation, the suspect space must be treated as a permit-required confined space and accessed as defined in the elements of this program. A permit-required confined space (permit space) has one or more of the following characteristics (reference the Definitions Section of this document) Contains or has the potential to contain a hazardous atmosphere. Contains a material that has the potential for engulfing the entrant Has an internal configuration such that an entrant could be trapped or asphyxiated by inwardly converging walls or by a floor that slopes. Contains any other recognized serious health hazard (e.g., hazardous energy, noise, fall, slip/trip-to be determined by the entry team). HAZARD RECOGNITION/IDENTIFICATION.JOB PLANNING Appropriate PRCS controls, work practices and employee protective equipment (if applicable) cannot be implemented until all possible hazards within the space are identified. Prior to initiation of any PRCS work, the entry team will evaluate the known and potential hazards associated with a specific entry. The participants conducting the evaluation shall consist at least of the entry supervisor. The attendant and the direct supervisor of the entrant may also be utilized to gather information regarding the hazards related to a specific entry. Use all of the elements of the entry permit and the Job Hazard Analysis form to assess the possible hazards that may exist as a result of the assigned scope of work. Issues that may be addressed include, but are not limited to: Previous materials stored in the space. Materials taken into the space (e.g., solvents, corrosives, etc.) Planned work practices that may contribute to the generation of hazards (e.g., hot work, cleaning, inerting, etc.) Space configuration hazards (e.g., restricted spaces, slopes, size/location of the space 33 openings and dead ends). Hazardous Energies like chemical, hydraulic, pneumatic, gravity, thermal, electrical, radiation and mechanical energies associated with the space. Physical hazards (e.g., noise, heat/cold, vibration and light)• Chemial hazards including the type of contaminants (known and potential), routes of entry and symptoms of exposure that could be manifested by exposed personnel. . Other atmospheric hazards such flammable and oxygen deficient/enriched environments. Conditions outside the space that may contribute to or add to the hazards within the PRCS (e.g., vehicle traffic, weather conditions and engulfing materials). All hazards identified will be documented in the confined space entry procedure and on the entry permit. The entry procedure must also specify the engineering controls, work practices and/or protective equipment to be used to control or eliminate the hazards identified for the specific entry. Details of the evaluation shall be reviewed by the entry team as part of the tailgate meeting prior to entry and documented on the entry permit. Should an unanticipated hazard arise during any part of the entry, the space will be immediately vacated, the entry team will conduct an assessment of the situation and the entry supervisor shall determine if the entry will continue. If the entry permit is cancelled, the entry supervisor shall document the reason for the cancellation PRCS PREPARATION When all existing and potential hazards within a confined space have been identified, appropriate preparation of the PRCS shall be conducted by the entry team. During the entire preparation phase, the entry supervisor shall review and approved all activities being performed. The confined entry procedure shall outline the following elements for each entry Scope of work. Job location. • • Recognized and potential hazards associated with the scop of work and controls/work practices incorporated to reduce or eliminate the hazards. Specialized equipment: work and safety related equipment must be listed separately. 1 Rescue Plan HOT WORK PREPARATION For the purposes of PRCS entry, hot work can involve grinding, cutting, welding, brazing or soldering, heating or other operations that generate heat, flames, arcs, sparks or other sources of ignition. • • When identifying hazards associated with hot work in confined spaces, it is important to evaluate the 'following: type of hot work to be performed; site preparation; atmospheric conditions; and, firefighting equipment. 'Evaluating the type of hot work to be performed ahead of time will assist in identifying the specific hazards relative to the type of hot work performed and the use of the appropriate' personal protective equipment. •, ' ' ' ' ' " ' 34 • ' : • ' ' -:•_, ' ' Site preparation should include a survey for the following: combustible materials; hazards posed by heat transfer; flammable, corrosive, or toxic residues; equipment linings; appropriate lockout/tagout application; and, housekeeping. As part of the standard practice for a PRCS entry, the atmosphere is monitored for Lower Explosive Limits (LEL). LEL must be maintained below 10% for confined space entry to occur or continue. The same is true for hot work performed in, around, or adjacent to a permit-required confined spaces. The hot work shall not be performed if the LEL is not maintained below 10%. HAZARD CONTROL Proper planning of a PRCS entry requires not only identifying the hazards (recognized and potential) related to the entry, but implementing a feasible control strategy for each. The following sections will detail several important hazard control strategies. It is important to note that this in only guideline and the entry team must evaluate each PRCS individually. All hazard control strategies must be documented in the confined space entry procedure and the entry permit. VENTILATION • Mechanical veitilation of a PRCS is accomplished by continuously moving fresh air from a clean source through the space. This may be done by forcibly blowing air into the space and, if necessary, exhausting air out of the space. Mechanical vent Mechanical ventilation of a PRCS is accomplished by continuously moving fresh air from a clean source through the space. This may be done by forcibly blowing air into the space and, if necessary, exhausting air out of the space EXPLOSION PROOF/SPECIALIZED EQUIPMENT Flammable gases and vapors can exist in a PRCS. The following are examples of ways in which this can occur: through threaded connections and gaps between mated surfaces, as a result of expansion and contraction due to temperature changes, by taking hazardous materials into spaces, and through the degradation of organic materials. To prevent the ignition of these gases and vapors, explosion-proof equipment may be used as a precautionary measure; in addition to explosion-proof equipment, intrinsically safe equipment and spark-proof tools can also be used as precautionary measures. Additionally, a variety of other different types of specialized equipment are available to ensure safe entry into a PRCS. Examples include but are not limited to: Atmospheric monitoring Equipment Personnel Protective Equipment Communications Equipment (e.g., radios) Ground Fault Circuit Interrupters (GFCI) Low-voltage Lighting Rescue equipment like a mechanical retrieval device Mechanical Ventilation Units In any case, the need for this type of equipment should be identified in the confined space entry procedure. Additionally, the entry team shall receive training on the proper use of any specialized equipment prior to entry. 35 CONTROL OF HAZARDOUS ENERGY During a PRCS entry, entrants may be exposed to the following forms of hazardous energy: electrical, mechanical, chemical, hydraulic, pneumatic, thermal, gravity, and radiation. These hazards should be identified in the confined space entry procedure. To protect employees from these potential hazards, the elements of Sancon's Hazardous Energy Control Program must be implemented as part of the entry. When it has been determined that the Hazardous Energy Control Program must be applied for the safety of the entrants, a procedure must be developed, to ensure that the hazardous energy is either eliminated or controlled. The hazardous energy control procedure should be attached to the written job plan. PROTECTIVE BARRIERS When a PRCS entry covers are removal of any kind of access hatch, to facilitate entry, the opening shall be guarded by railing, temporary cover, or other temporary barrier. This will prevent an accidental fall through the opening and will protect the entrant from foreign objects entering the space. TRAFFIC/PEDESTRIAN CONTROL When a PRCS entry covers are removal of any kind of access hatch, to facilitate entry, the opening shall be guarded by railing, temporary cover, or other temporary barrier. This will prevent an accidental fall through the opening and willprotect the entrant from foreign objects entering the space. Protection from traffic/pedestrian hazards can be provided through the use of effective traffic control devices. Traffic control devices can control the hazards posed by vehicular traffic, but they cannot eliminate them. It is important to pre-plan the work site for traffic control device placement and use work vehicles and natural barriers as protective devices to the fullest extent possible. Use recommended traffic control references such as the "Manual on Uniform Traffic Control Devices" (M1JTCD) or the "Work Area Traffic Control Handbook" (WATCH Manual). PERSONAL PROTECTIVE EQUIPMENT Head protection: Hard hats shall be worn whenever the potential for head injury exists. They are intended to provide protection from impact and penetration by falling objects and bumps into stationary objects. In addition, hard hats afford some protection from splash hazards and electrical hazards. If possible, these hazards should be controlled or eliminated prior to entry into a PRCS. Remember, hard hats are nothing more than a barrier between the entrant and the hazard. Eye and Face Protection: Work activities can expose the eyes to a variety of hazards, which can include the following: flying objects, hazardous materials splash, dusts, injurious light, etc. There are different types of eye protection available. Selection of the appropriate eye protection depends upon the actual work to be performed and the hazard potential presented by the job and location. Available eye protection includes: safety glasses, goggles (eyecup and cover-type styles), directly ventilated goggles, and indirectly ventilated goggles. Welding operations require the use of appropriate eye protection as well. Work activities can also involve work activities that require protection of the face from similar hazards that are posed to the eyes. Face shields are used to protect the workers face and neck. Welding operations may also require the use of face & head protection in the form of a welding helmet. Eye protection should be used in conjunction with face protection. Selection of the proper personal protective equipment depends upon the work activities performed and the hazards present in the permit-required confined space. 36 Hand: Hands and fingers can be exposed to a number of different hazards during a PRCS entry. Examples of potential hazards can include cuts, scratches, bruises, bums, and chemical exposures as well as others. During the preparation phase of each entry, these hazards must be identified. In addition, the appropriate type of protective glove should be used for the type of hazard(s) present. Foot: The type scope of work in the PRCS will also dictate the appropriate foot protection required for the entry. Hazards with potential for compression, impact, puncture, chemical exposure, etc. will have to be evaluated, and selection of foot wear will be based on the hazard(s) present. Respirators: Hazardous atmospheres in a PRCS can be present because of a number of different factors. For example, the atmosphere in the space may be inherently hazardous or the work practices and/or materials introduced into the space may cause an impact on the work environment. Whatever the reason, atmospheric hazards in a PRCS should be reduced or eliminated whenever possible. While preparing the confined space entry procedure, potential atmospheric hazards must be identified and appropriate controls will be evaluated to reduce/eliminate the hazard(s). In those cases, where the hazardous atmosphere cannot be reduced to an acceptable level or eliminated, the proper respiratory protection will be identified for use by the entry supervisor. There are two general categories of respiratory protection available for use: air purifying devices and air-supplied devices. Hearing Protection: While preparing the confined space entry procedure, the potential for elevated noise levels must be evaluated. It is important to remember that low noise levels associated with work activities that are performed in open areas may become hazardous noise levels when those same work activities are performed in a PRCS. There are two types of hearing protection devices available at the Shop: ear-muffs and earplugs. Body: Full-body protection may be required for authorized entrants during entry into a PRCS. Full-body protection may be necessary to guard against exposures like the following: heat and cold stresses; chemicals, hazardous materials handling and biological contaminants. Again, as part of preparing the confined space entry procedure, the specific hazards associated with the space will be evaluated and the necessary. full-body protection must be determined. Fall: Due to the location and access limitations associated with a PRCS, fall hazards may be present during entry operations. As part of preparation of the confined space entry procedure, potential same level and different level fall hazards must be evaluated and the proper fall protection method implemented. ENTRY PERMIT SYSTEM The importance of completing an entry permit prior to a PRCS entry cannot be understated. This section will detail procedures for preparing, issuing and canceling an entry permit. PREPARATION OF THE PERMIT Responsibility for the accurate and complete preparation of the permit rests with the entry supervisor. Entry authorization will not be granted until the entry supervisor completes and signs the entry permit / Satisfactory preparation of the permit shall minimally include the following information: The permit space to be entered The purpose of the entry 37 The date and authorized duration of the entry permit The authorized entrants within the space by name so that the attendant can quickly and accurately. determine which authorized entrants are in the space The attendant(s) by name The entry supervisor by name and his/her signature authorizing entry The hazards of the permit space to be entered The measures used to isolate the space and to eliminate or èontrol PRCS hazards prior to entry The acceptable entry conditions The results of the atmospheric pre-entry test, the periodic atmospheric testing results, the name of the tester(s), and the date and the time indicating when the tests were performed The rescue method(s) and emergency response ISSUANCE OF PERMITS The entry permit must be posted at the job site and available for review by all entrants to the permit- required confined space. The duration of the permit must not exceed the time required to complete the tasks identified on the permit. If the scope of the work to be performed within the space changes then a new permit should be issue. CANCELLATION OF PERMITS The entry supervisor must terminate entry activities and cancel the permit when: the work activities have been completed and If conditions not allowed under the permit arise in or near the space. All canceled permits must be sent to the Safety Manager within 5 working days of the completed entry. •: A post entry evaluation must be done upon completion of each entry. EMPLOYEE DESIGNATION AND DUTIES The confined space entry team consists of the: Authorized Entrant(s) Attendant(s) t Entry supervisor. Each team member has a specific role to ensure a safe, entry. Confined space entry must not be performed with untrained entry team members. AUTHORIZED ENTRANT • I The authorized entrant is the employee who is allowed to enter the space to perform work. The entrant is the team member who is at greatest risk in the entry operation. • The entrant must know the potential hazards of the space and the consequences of exposure to the hazards. The entrant must follow safe work practices and procedures and be able to recognize the modes, signs and symptoms of exposure to the hazards in the space. The entrant must be properly trained in the use of the equipment used during the entry. 38 • • The entrant is responsible for communicating with and alerting the attendant is problems develop inside the space. The entrant must immediately evacuate the space if dangerous conditions develop or if an evacuation alarm is activated. - ATTENDANT The attendant is stationed outside of the space to monitor conditions in and around the space, watch the activities of the entrant and summon rescue services in The event of an emergency. The attendant may monitor more than one confined space provided that they can track and identify the authorized entrants entering the spaces. The attendant must also know the potential hazards in the space and the mode, signs and symptoms, and consequences of exposure By knowing this information, the attendant will be able to identify the possible behavioral effects of the hazards on the entrant. The attendant must maintain a continuous count of the number of entrants and keep unauthorized personnel out of and away from the space. The attendant must remain outside of the space until relieved by another attendant. If the attendant must leave or perform other duties, the confined space entry must be terminated and the entrants must evacuate the space until a full entry team is available. ENTRY SUPERVISOR The entry supervisor does not have to be an employe working in the supervisor position classification. The entry supervisor is an individual who is responsible for enforcing workplace rules and policies. - - This individual may be a working as lead worker or a foreman but may include any job classification approved for confined space entry. The entry supervisor is responsible for all aspects of the entry operations. The entry supervisor is responsible for checking the permit to make sure it is properly completed and all precautions have been taken. The entry supervisor authorizes the entry by signing the permit. Conducts a pre-entry tailgate meeting with the entry team to discuss the scope of work, recognized/potential hazards in the space and the controls implemented, verification that the entry team has been trained on the equipment used for the entry and symptoms of exposure and consequences of exposure to recognized or potential hazards in the PRCS. Cancel entry authorization and/or terminate entry whenever acceptable entry conditions are not present. Once the scope of work has been completed, the entry supervisor also must terminate the entry and cancel the permit Verify that an appropriate rescue plan is in place. Prior to switching entry supervisors (shift change), the outgoing entry supervisor is responsible for determining that entry conditions are consistent with the terms of the permit and acceptable entry conditions are present before turning over operations to. the incoming entry supervisor. ATMOSPHERIC TESTING AND MONITORING Cal/OSHA requires atmospheric testing for two distinct pürp6ses: . Evaluation of the hazards of the permit space. 39 ( Verification that acceptable entry conditions exist in .the PRCS prior to entry. Preparation of the confined space entry procedure shall include recognized and potential atmospheric hazards related to each entry to ensure that the entry team monitors for the appropriate hazards. .. This monitoring may include the use of remote sampling devices to assist in sampling from outside of the space. After the initial monitoring has been conducted, it is necessary to continue to monitor the atmosphere to ensure that conditions do not change. Monitoring instruments and visual inspections are used to evaluate the conditions of the space. Instrumentation is used to evaluate environmental conditions such as air contaminants, oxygen deficiency or enrichment, noise, radiation, etc. Visual inspections are used to ensure effectiveness of hazard controls, barriers, etc. All employees using monitoring equipment must be trained on the use and limitations of the equipment. Sancon shall provide continuous direct-reading instruments to. measure: Oxygen levels between 19.5 % to 23.5% Hydrogen sulfide (H2S) below 10 PPM 3. Lower explosive limit below 10% 4. Carbon monoxide below 25 PPM Sancon calibrates the gas detection instruments per the manufacture's recommendations. Entry team members must never use instruments, which are not properly calibrated. The entry shall be terminated if there is any question concerning the accuracy of the monitoring instrumentation. . Initial air monitoring must be conducted from outside the PRCS. The entry supervisor will specify on the entry procedure and the entry permit, the frequency and duration of tests to be conducted for the PRCS. Measurement of values for each atmospheric test should be made for at least the minimum response time of the instrument, as, specified by the manufacturer. Cal/OSHA requires testing for atmospheric hazards in the following order 1. Oxygen 2 Combustible gases 3. Toxic gases/vapors •. The confined space entry procedure and the entry permit will identify the contaminant sampling parameters specific to each entry. Monitoring in stratified (layered) atmospheres shall be performed from outside starting at tQp/front of the PRCS and every five feet of travel, and to .each side, to the end of the space. If it is not feasible to monitor the entire space in this matter, then the entry will have to be performed with each entrant wearing a supplied air respirator, with 15-minute escape bottle, until air monitoring indicates the space may be entered without any respiratory protection. RESCUE AND EMERGENCY PROCEDURES . • All confined space entry procedures must include rescue/emergency response language. There are two types of emergencies encountered in confined space entry. 1. The confined space hazards were recognized and precautions were taken but the • • control program was not effective. •. ., 2. The confined space hazards were not recognized and the appropriate precautions were not taken. • • .-•. i • 40 , . , The confined space hazards were recognized and precautions were taken but the control program was not effective. The confined space hazards were not recognized and the appropriate precautions were not taken. The confined space entry procedure must identify the type of rescue and this information must be communicated to the entry team. I. There are several types of emergency rescue. Evacuation or Self-Rescue: This type of rescue is initiated by the attendant or entrant ordering an evacuation of the space. The entrant exits the space on his own. (Examples of this may be the entrant crawling out of a side wall entry port in an above ground tank or the entrant climbing up a ladder.) Assisted Non-Entry Rescue: This type of rescue involves a single victim who may or may not be conscious. The entrant wears a full-body harness and is attached to a mechanical retrieval device located outside of the space. The attendant operates the mechanical retrieval device, which pulls the entrant from the space without the need for entry. Retrieval systems must comply with Cal/OSHA requirements (Title 8 CCR, Section 5157 (k)(3)). Entry Rescue: This type of rescue is usually for the most critical types of incidents. The configuration of the space may prohibit the use of mechanical retrieval devices from the outside. The rescue involves a rescue team entering the space to remove the victims. This type of rescue may be performed by an on-site rescue team, contractor or the fire department. . If the local fire department or contractor is identified as the rescue team in the confined space entry procedure, it is the responsibility of the entry supervisor to coordinate this contingency. In the event an injured entrant(s) is exposed to a chemical substance, the Material Safety Data Sheet (MSDS) must be kept at the worksite and be made available to the emergency medical responder and the treating medical facility. This is to ensure appropriate medical treatment of the victim(s) and to avoid unnecessary exposure to medical personnel. INFORMATION AND TRAINING - Employee training is an integral component of Sancon's PRCS program. The required training for each entry team member must be conducted prior to the employee's initial assigned confined space duties. Additional training is required if there is a change in the potential hazards or the permit space operations or if there is any reason to believe that there are deviations from approved work practices. Sancon provides initial and refresher training for employees involved in confined space entry. Additionally, awareness training is provided to staff whose job classification requires support of confined space entry work, but are not a part of an entry team. 1. The Entry Team must be trained on: The duties of the authorized entrant Basic first aid and CPR Air monitoring instrumentation use Mechanical retrieval equipment use -. Personal protective equipment use Communication equipment use 41 • Supplied air respirator use In addition, the Rescue Team members must simulate a rescue at least every 12 months. The training programs for the entrant, attendant, entry supervisor, and rescue team must satisfy the requirements described in Title 8, Section 5157, (g) - (k). PROGRAM REVIEW AND RECORD KEEPING The Safety Manager is responsible for maintaining all cancelled confined space entry / permits, air monitoring data, IHAs and confined space entry procedures for one year. This includes review of the permit to identify any problems encountered during the entry. The written program will be reviewed annually to ensure the program is updated to include changes in the regulations and to incorporate new work practices and equipment. 1 • Employee training records are maintained in the computerized Training Record System and keep for five years ENFORCEMENT / DISCIPLINE It is the responsibility of each Sancon employee to ensure that safety is an integral part of our day to day activities. Sometimes it's necessary to discipline employees when there is a safety policy/program violation. Due to the potential severity of the not following proper procedures during confined space entry, a willful violation of the District's PRCS program may be grounds for disciplinary action leading up to and including termination. PROGRAM ADMINISTRATION • PROGRAM EVALUATION • This Permit Required Confined Space Program shall be evaluated annually to ensure that it is effective in providing adequate protection the release of hazardous energy during maintenance activities. REFERENCES Title 8, California Code of Regulations, Section 5156, Scope, Application and Definitions •. Title 8, California Code of Regulations, Section 5157, Permit-Required Confined Spaces Title 8, California Code of Regulations, Section 5158, Other Confined Space Operations Title 29, Code of Federal Regulations, Part 1910.146 Permit Required Confined Spaces ANSI Z244.1-1982 (R 1993) Lock Out/Tag Out of Energy Sources, Safety Requirements -• 42 Z 5841 Engineer Dr- . Huntington Beach, CA 92649 F P:(714)891-2323 CONFINED SPACE ENTRY PERMIT F:(714) 891-2524 lob Date Site Location or Description / Authoth,ed EntrarLt(s)__________________________________________________________ S{_______ Auth dAtteiudari4s)_______________________________________________ lime Issued AM / PM lime Expires AM I PM Purpose of Entry - A) EuIRYcOrDmOnsjPROcEn1mES: N/A YES NO L HAZARDS IDENTIFIED AND EXPLAINED? (List Below) 2. lNmALA1MosPltErnc IES1UW (All Levels)? ( ) t ) ( ) 3. SPACE ISOLATION REQUIRED? (Bypass, Fluthing, Pumping; etc.) ( ) t ) U I & VENTILATION (Mechanical or Natural)? ( ) I ) ( ) ATMOSPIIERIC TEST AFTBIVENflLA11ON ( ) ( ) ( LIFELINES/HARNESS BELTS WORN? ( ) ( ) ( EMEKGBNCYPROcDURES/REScUEEQUIPMENr? ( ) ( ) ( &.TRAINED SANDY PERSONNEL? ( ) ( ) ( COMMUNICATION SYSTEM (Voice/Powered)? PERIODIC Alit TESTING? (Record) ( ) I ) I ADEQUATE ILLUMINATION? PROTECTIVE CLO1HINGJQUIPMENT WORN? ( ) I ) ( 3 / ATMOSPIIERICTESTEQUIPMENT USED: PROTECTIVE EQUIPMENT" AVAiLAB[E/USED: Hard Hat Safety Lute & Harness Hearing Protectron______ Gas Tester Air Blower Tripod & Fall Protection_______ Illumination Forced Air Contained Breathing Aparatus________ All Conditions Satisfactory for Entry? Supervisor/Lead Person Name DATE TIME Supervisor/Lead Person Signature \ LUNIINW rat IT cont. ATMOSPHERIC SAMPIJP1G RESULTS - RECORD DATA EVERY 15 MIN. (UNlESS CONDIJONS WMRANI CONTINUOUS MON]TORThG)! POWER BLOWERS Labeling All power blowers must be labeled to indicate the certified effective net capacity at the end of the 15-foot standard blower hose. These capacities are rated with one 90-degree hose bend (usual arrangement for initial purge) and two 90-degree hose bends (normal arrangement for continuous ventilation). If labels are missing, obtain them from the shop personnel. Purge Time Determination Explosive gases: Of the flammable gases commonly reported in manholes, gasoline vapors have the lowest explosive limit (LEL). Based upon reducing a gasoline vapor contaminated manhole to below the 10% of the LEL (1300 parts per million (ppm), the required purge time of all conventional sizes can be determined by: t = 7.5 V/R. AT NO TIME SHALL PURGING TIME BE LESS THAN 5 MINUTES. Where t purge time (minutes) V = manhole volume R = effective net blower capacity Toxic gases: • In all sewer related spaces and other spaces where toxic gases may be present, such as hydrogen sulfide, purge time should be increased 50% above that as determined for the 10% LEL for gasoline criteria. This can be determined by: t = 11.1 VIR. Continuous Ventilation: Following the purging requirements, the manhole shall be continuously ventilated so long as it is occupied by anyone, even momentarily. Continuous ventilation may be at lower rates than what is requiied for purging but not less than 334 cfm measured at the end of the blower hose with two (2) 90-degree bends. ) 45 • • RESPIRATOR PROTECTION PROGRAM Purpose Employees may be exposed to air contaminated with harmful dusts, fogs, fumes, mists, gases, smokes, sprays, or vapors or oxygen deficient atmospheres, during their normal work Activities. Sancon has attempted to remove these potentially dangerous conditions through the use of engineering controls where feasible. Engineering controls are not always feasible due to the remoteness of a location, the confines of a work area or in emergency situations. In an effort to control employee exposures to respiratory, hazards, Sancon has developed this Respiratory Protection Program. All respiratory protective equipment shall be issued and used pursuant to this Policy. The purpose of this Respiratory Protection Program and Policy is to establish a program that will protect employees from potentially harmful atmospheres by establishing the requirements for the selection, use, care and maintenance of respiratory protection equipment. This program also establishes the voluntary use, medical and training requirements for respiratory protective equipment and its users. RESPIRATORY SELECTION Respirators shall be selected based on a workplace survey of potential and known respiratory hazards. Voluntary use of respiratory protective equipment is allowed with the approval of the Respiratory Program Administrator. ' Sancon shall conduct a hazard assessment survey to determine which workplace hazards have respiratory hazards and to determine the conditions encountered by employees exposed to respiratory hazards. ,. The proper type of respirator shall be selected for each work place where a respiratory hazard exists. ' Respirators for voluntary use, where a respiratory hazard does not exist shall be selected by the same means. Only respirators approved by the National Institutes of Occupational Safety and Health (NIOSH) shall be selected and used. CHEMICAL CARTRIDGE: Each employee shall be assigned a chemical respirator and shall be fitted and instructed on its use. Employees will be responsible for safekeeping, cleaning and maintenance of their respirator. Each worker shall keep his respirator stored in its protective case and used only by himself. After each day's use worn or deteriorated parts shall be replaced as needed. Employees shall ask for a replacement respirator at any time a respirator's condition is in question. 46 DISPOSABLE FORCED AIR HOODS Disposable forced air hoods shall be provided for each employee as necessary. It is the employee's responsibility to inspect the hood periodically for tears or leaks. A new hood should be used at the beginning of each day and changed-as needed FORCED FEED BREATHING AIR Forced feed air must be filtered and monitored for carbon monoxide when being drawn off an oil air compressor. The carbon monoxide meter and alarm musfbe turned on and checked for correct operation daily. At no time shall an employee use a breathing air support hood supplied from a compressor which has indicated carbon monoxide levels of 20 PPM or greater. At no time shall a breathing air supported hood be connected to an oil compressor, which does not have a high discharge temperature shut down. DISPOSABLE PAPER DUST/MIST I Disposable paper dust/mist respirators shall be made available at all times for use in protection against the following only: .. Overspray of Sancon 100 outside confined space. Copper Slag Dust outside of a confined space. Do not use a dust/mist respirator to protect against chemical gases such as the fumes from sealers, primers, paints or solvents. Of primary importance is whenever you feel sick, dizzy, or lightheaded; immediately stop work and come into fresh air. Do not return to work until such time as.the cause of illness is determined. MEDICAL EVALUATION Using a respirator may place a physiological burden on an employee, which varies with the type of respirator worn, the job and workplace conditions in which the respirator is used, and the medical status of the employee. A respirator may produce undeirable physiological and psychological effects on the wearer. Employees must not be assigned tasks that require the use of a respirator unless a licensed health care professional has determined they are physically capable of performing work while wearing respiratory protective equipment. Employees may refuse work that requires the use of a respirator if they have not been medically qualified in the previous 12 months Medical evaluation shall be provided to the employee at no cost during working hours Medical evaluation shall be performed by licensed health care professional. Employees shall be ,valuated annually by a Physician or other licensed health care professional. 47 . RESPIRATOR USE AND EMERGENCIES This section outlines the procedures and responsibilities for the proper use of respirators during normal operations and emergency situations. RESPIRATOR USAGE Employees shall use respiratory protective equipment in areas designated as respiratory protective equipment use areas. Employees who require prescription eyewear to correct vision shall not allow eyeglass temple bars to interfere with the seal of the respirator. Prescription eyéwear for respiratory protective equipment users may be obtained. Employees shall inspect their respirators before entering areas or performing tasks that require their usage. Employees shall not use respiratory protective equipment that is defective. When there is a change in work area conditions or degree of employee exposure or stress that may affect respirator effectiveness, Sancon shall reevaluate the continued effectiveness of the respirator. RESPIRATORY USAGE IN IMMEDIATELY DANGEROUS TO LIFE AND HEALTH (IDLH) ATMOSPHERES U The required respiratory protection for IDLH conditions caused by the presence of toxic materials or a reduced percentage of oxygen is a positive pressure SCBA or a combination supplied air respirator with an escape bottle. If an employee must work in an atmosphere that is immediately dangerous to life and health ([DLH), theemployee shall comply with the requirements this respiratory protection program. EMERGENCY SITUATIONS INVOLVING RESPIRATORY EQUIPMENT In the event of an emergency situation that will require the use of respiratory protective equipment, only a positive pressure SCBA shall be used. The use of other respiratory protective equipment for emergency situations shall not be allowed without the approval Supervisor, or designee. FIT TESTING . All respirators that rely on a mask-to-face seal need to be annually checked with a qualitative method to determine whether the mask provides an acceptable fit to a wearer. Qualitative fit test procedures shall be used and conducted in accordance with CAL-OSHA 5144 Respiratory Protection Program All employees who wear respiratory protective equipment shall receive a fit test at least annually. Fit tests shall be completed on a more frequent basis if: • The employee uses more than one type of respirator face piece. The employee gains or loses more than 15 pounds in weight and notifies the Respiratory Program Administrator of the change. C. The employee believes that his or her selected respirator is no longer providing an adequate fit. Cal-OSHA prohibits facial hair in places on the face and neck where it can interfere with the 48 • seal of a respirator on the face of the use1. Therefore, employee's whose job classifications require the use of respiratory protective equipment shall be prohibited from wearing of facial hair from all areas of the face and body, which may interfere with the. seal of respiratory protective equipment. Employees who voluntarily wear respiratory protective equipment shall be prohibited from wearing of facial hair from all areas of the body, which may interfere with the seal of respiratory protective equipment. Employees who may be required to infrequently wear respiratory protective equipment and have the ability to shave prior to respiratory protection use, may have facial hair as long as it is removed prior to being fit tested or having to wear a respirator RESPIATOR CLEANING, MAINTENANCE, AND STORAGE The cleaning, maintenance and storage of respiratory protective equipment is vital to an effective Respiratory Protective Program. Each respirator user shall be provided with a respirator that is clean, sanitary, and in good working order. It is the responsibility of each employee who is assigned a respirator to ensure that his or her personal respirator is properly inspected, disinfected and maintained. All respirators shall be inspected by their user before each use and during cleaning *All respirators maintained for use in emergency situations shall be inspected at.least monthly by the respirator owner (Safety manager or supervisor) and in accordance with the manufacturer's recommendations, *It is the inspecting employee's responsibility to inform the supervisor of defective equipment when discovered. • • ( *Respirators issued for the exclusive use of an employee shall be cleaned and disinfected by the employee s often as necessary to be maintained in a sanitary condition. All respirators shall be stored to protect them from damage, contamination, dust, sunlight, extreme temperatures, excessive moisture, and damaging chemicals. They shall be packed or stored to prevent deformation of the lace piece and exhalation valve. TRAINING PROGRAM Each employee shall be trained in the 'proper use of respirators, including putting on and removing them, any limitations on their use, and their maintenance, cleaning, and storage. Training shall be provided prior to requiring the employee to use a respirator in the workplace. Retraining shall be administered annually, and when the following situation(s) occur. Changes in the workplace or the type of respirator render previous training obsolete. If the employee cannot demonstrate knowledge of or use the respirator. Any other situation arises in which retraining appears necessary to ensure safe respirator use. All training will be recorded in the Sancon Master Training Record and keep for five years. PROGRAM ADMINISTATION AND REVIEW The Respiratory Program shall be managed and administered by the Safety Administrator. t. This Respiratory Protection Program shall be evaluated annually to ensure that it is effective, 49 in providing adequate protection against the inhalation of harmful atmospheres. FIRST AID AND EMERGENCY PLANNING All employees should anticipate the effect of a major emergency or disaster on their operations and plan a course of action that will minimize personal injury and property damage in the event of any fire, industrial hazard, or natural disaster. The following actions are recommended insofar as they are applicable to a particular- situation. Additional measures may be taken as the situation warrants. S Every individual is responsible for knowing the following information concerning the buildings or areas to which they are assigned: Location of telephones and fire alarm boxes, if any. Location of fire extinguishers. 3: His duties in the event of fire. 4. The location of exits. Keep them clear and accessibler. -• Action in Case of a Fire (Smoke or Water) Danger, 1. What todo if you spot a fire: • If deemed appropriate, return to the fire with an extinguisher; If the fire cannot be controlled, evacuation of the premises should begin. Advise employees and viitors to stay low to the ground, since smoke rises. C. Call the fire department d. Never put yourself or others in jeopardy. At no time during a fire emergency • should property be considered before people. The safety of employees and visitors must come first. • 2. • Safety Personnel Responsibilities A representative of the company, preferably a member of the Safety Committee will be designated as the liaison between the Company and the Fire Department leader. • • 3. Fire Prevention and Fire Safety S All individuals will immediately correct and/or report to management, any observed fire hazard or unusual condition that might lead to the development of a fire. 50 -I, Bomb Threats - In the event a bomb threat is telephoned in, whoever receives the call should notify a supervisor immediately. Should a bomb threat occur, remain calm and follow instructions as given by management? Management will notify the proper authorities and employees and visitors will be instructed to evacuate the premises via the nearest exit route. As soon as danger passes, an authorized "all-clear" will be issued and employees and visitors will be allowed to return and resume work. - Earthquake or Natural Disaster - In the event of an earthquake or related disaster (explosion, Lightning-strike), the following general measures should be taken: Drop to the floor and get under a desk or table. Stay away from windows, bookshelves or any freestanding cabinets: Following any shocks, attempt to secure your area. Do not leave the building until the shocks have 'subsided. 5 Follow the instructions of any Safety Engineer present Evacuation Flow Plan An evacuation flow plan for this project is kept on jobsite bulletin boards and jobsite offices. r HEAT ILLNESS PREVENTION PLAN Purpose The purpose of Heat Illness Prevention Plan is to meet the requirements set forth in California Code of Regulations, Title 8, Section 3395, (for complete guidelines please see Heat Illness Prevention Regulation Amendments in the Appendix) and also to serve as a supplement to Sancon Engineering's Injury and Illness Prevention Program (IIPP). This information is intended and must be used in conjunction with the IIPP. The Heat Illness Prevention Guide establishes procedures and provides information which is necessary to ensure that members of Sancon Engineering are knowledgeable in the prevention and recognition of heat stress to ensure their own safety and the safety of others. Heat Illness Prevention Heat related illnesses are avoidable if the employees are trained and the right actions are taken before, during, and after working in either indoor or outdoor hot conditions. High temperatures and humidity can stress the bpdy's ability to cool itself making heat illness a big 51 concern during hot weather months. Every employee whose job duties require them to work in the outdoors during summer months, are exposed to elevated heat conditions and therefore are susceptible to heat illness. The three major forms of heat illnesses are: heat cramps, heat exhaustion, and heat stroke. Heat stroke can be a life-threatening condition. This document will outline those actions as well as describing the three major forms of heat illness, 'how to recognize them, and what actions to take to provide first aid before medical care is provided. Heat Cramps Description: Heat cramps are the most common type of heat related injury and probably have been experienced by nearly everyone at one time or another. Heat cramps are muscle spasms which usually affect the arms, legs, or stomach. Frequently they do not occur until sometime later after work, at night, or when relaxing. Heat cramps are caused by heavy sweating, especially when water is not replaced quickly enough. Although heat cramps can be quite painful, they usually don't result in permanent damage. Prevention/First Aid: Drink electrolyte solutions such as Gatorade or plenty of water during the day and try eating more fruits such as bananas to help your body stay hydrated during hot weather. Contact your supervisor immediately if the person becomes ill. - Heat Exhaustion Description: Heat exhaustion is more serious than heat cramps. It occurs when the body's internal - temperature regulating system is overworked, but has not completely shut down. In heat exhaustion, the surface blood vessels and capillaries, which originally enlarged to cool the blood, collapse from loss of body fluids and necessary minerals. This happens when you do not drink enough fluids to replace what you are sweating away. Symptoms Include: Headache, heavy sweating, intense thirst, dizziness, fatigue, loss of coordination, nausea, impaired judgment, loss of appetite, hyperventilation, tingling in hands or feet, anxiety, cool moist skin, weak and rapid pulse (120-200), and low to normal blood pressure. Prevention/First Aid: The employee suffering these symptoms should be moved to a cool location such as a shaded area or air-conditioned building. Have them lie down with their feet slightly elevated. Loosen their clothing, apply cool, wet cloths or fan them. Have them drink water or an electrolyte drink. Try to cool them down, and have them checked by medical personnel. Victims of heat exhaustion should avoid strenuous activity for at least a day, and they should continue to drink water to replace lost body fluids. Call 911 if the person becomes non- responsive, refuses water, vomits, or loses consciousness. 3. Heat Stroke Description: Heat stroke is a life threatening illness with a high death rate. It occurs when the body has depleted its supply of water and salt, and the victim's core body temperature rises to deadly I 52 levels. A heat stroke victim may first suffer heat cramps and/or heat exhaustion before progressing into the heat stroke stage, but this is not always the case. It should be noted that, on the job, heat stroke is sometimes mistaken for a heart attack. It is therefore very important to be able to recognize the signs and symptoms of heat stroke - and to check for them anytime an employee collapses while working in a hot environment. Symptoms Include: A high body temperature (103 degrees F); a distinct absence of sweating (usually); hot red or flushed dry skin; rapid pulse; difficulty breathing; constricted pupils; any/all the signs or symptoms of heat exhaustion such as dizziness, headache, nausea, vomiting, or confusion, and possibly more severe systems including; bizarre behavior; and high blood pressure. Advanced symptoms may be seizure or convulsions, collapse, loss of consciousness, and a body temperature of over 108 degrees F. Prevention/First Aid: It is vital to lower a heat stroke victim's body temperature. Quick actions can mean the difference between life and death. Pour water on them, fan them, or apply cold packs. Call 911 to get the person medical aid as soon as possible. Precautions to Prevent Heat hines Condition yourself for working in hot environments. Start slowly then build up to more physical work. Allow your body to adjust over a few days (acclimatization). Drink plenty of liquids. Hydration is a continuous process. Don't wait until you're thirsty! By then, there's a good chance that you're already on your way to being dehydrated. Electrolyte drinks are good for replacing both water and minerals lost through sweating. Never drink alcohol, and avoid caffeinated beverages like coffee and soda as these liquids can have the opposite effect and can actually increase the level of dehydration. Take frequent breaks, especially if you notice you're getting a headache or you start feeling overheated. Adequate water and shade will be provided at the job site before work is to begin. Water will be provided by Sancon Engineering. Pick up bottled water from the shop. If you run out purchase water at the store and you will, be reimbursed. One quart, per employee, per hour is required. Shade will be provided when the temperature exceeds 80 degrees, Fahrenheit, by natural surroundings, EZ-Up awnings, Air conditioned Camera Truck or in the cab of our air conditioned job trucks. r Wear lightweight, light colored clothing when working out in the sun. If the temperature reaches 95 degrees Fahrenheit or above, the employer shall ensure that the employee takes a minimum ten-minute cool down rest every two hours. It may be provided concurrently with any other rest period or meal period. ' 53 - ,. Immediately report all unsafe conditions and/or concerns to your supervisor without delay. For the complete guide please see Heat Illness Prevention Regulation Amendments in Appendix. HAZARDOUS ENERGYCONTROL PROGRAM (LOCKOUT TAG-OUT PROCEDURES) Policy Equipment should be properly and uniformly locked out and tagged whenevr it is down for any reason, in order to protect the exposed employees from inadvertent equipment operation and potential harm. Purpose The purpose of this section is to provide a safe method for rendering inactive any electrical equipment or operating systems (including mechanical or piping) when equipment is down for any reason, such as repair, removal or replacement. This procedure is provided in an effort to identify certain LOTO procedural elements. The Subcontractor's or other Agency's program may not exactly follow this procedure; however, the basic elements shall be available to protect all employees from the potentialhazards. A JSA is required and must be reviewed and accepted by the Sancon Safety Manager or Supervisor prior to the start of work. Responsibilities When needed, the Subcontractor or other Agencies are responsible to assure that a LOTO procedure is put in place in their area of work. The Project Manager is responsible to ensure that all construction employees are trained and familiar with and use the procedure wherever it applies. All employees are responsible to be aware that a LOTO Program is in effect and the specifics of the Subcontractor's or other Agency's program. Anyone who may be exposed to the sudden release of energy or materials will be familiar with and abide by the established LOTO procedure. If an employee observes a safety problem, he/she will notify their Supervisor, the Subcontractor or other Agency 's responsible for the area Safety. Implementation A LOTO procedure should include five basic phases of work on any system: (1) shutting down equipment, (2) verify energy is released, (3) repairing or installing equipment, (4) removal of LOTO devices, and (5) startup of equipment. It is likely that some situations will not include all five phases' as such; however, regardless of the operation and the phase or phases involved, the "lockout/tag-out" clearance procedure must be observed to assure the safety of the operation. 54 Even though this procedure generally provides for locking and tagging of equipment, the danger tag alone is to be considered and inviolable device and any equipment bearing such a tag must not be operated under any circumstances. Also, locks must be used in conjunction with a tag to afford maximum personnel protection. Prior to starting any major operation, which would involve these locking and tagging procedures, a meeting shall be set up by the supervision, employees and inspectors involved. The project's safety personnel shall attend this meeting. A specific procedure will be adopted and reviewed by all concerned with the operation, prior to commencement of work. Materials and Hardware Sancon shall provide accidental prevention sins, tags, padlocks, seals or other similarly effective means, which may be required for cleaning, servicing, adjusting, repair work or setting-up operations. Signs, tags, padlocks, and seals shall have means by which they can be readily secured to the controls. Tagout device attachment means shall in a non-reusable type, attached by hand, self-locking, and non-releasable with a minimum unlocking strength of no less than 50 pounds. Shutdown and RepairofEguioment or Systems All personnel, before working on equipment should assure that: Others are not working on the piece or system, and if others are working on it, that this procedure will not endanger any personnel or the equipment. Equipment is not under pressure, energized, at elevated temperature or otherwise unsafe to be worked upon. Others adjacent to the work area are not endangered. I Before starting work, the supervisor shall contact the designated supervisor (responsible for the equipment or system). This supervisor will show him the devices that require tagging; i.e., switches, starters, valves, lockout controls, etc. This will be accomplished by using an approved danger tag and lock. The main disconnect shall be opened in addition to any remote control switches. On electrical work, it is advisable as a further precaution for the electrician to remove the supply fuses. On piped systems, the main valves shall be closed and pressure relieved. The supervisor shall make sure that the equipment or system is inoperative. After assuring himself that the equipment has been properly shut down in accordance with the procedures described above, the supervisor and employees involved in the work shall positively determine that the equipment or system has been locked and tagged. Each employee will place his/her own tag and lock on the switch or valve. A distinctive danger tag and lock (when possible) will be attached to each device. This tag shall be dated and signed by the individuals doing the work. A short explanation of the reason for the tag should appear in the provided spaces. Only authorized personnel will repair specific equipment with system danger tags. If mechanically possible, a padlock (to which only the employee .placing the lock shall have access to keys) shall be placed on equipment in such a manner as to render operation of the equipment impossible. Starting Up Equipment or Systems As soon as the work is completed, the danger tags and locks shall be removed p.11y by the individuals installing them. In the event the shift ends before the work is completed, the status of the work is to be reported in detail to the oncoming shift personnel and the tags and locks on the system replaced by the oncoming shift personnel. 55 Upon completion of the work, Sancon, the Subcontractor or Agency supervisor will make certain all tags and locks have been removed and personnel are clear of the equipment or system. The equipment will be returned to normal operating conditions. General In an emergency, or if the person who placed the tag and lock is not available the Lock and Tag Removal Procedure established by Sancon, the Subcontractor's or other Agency's LOTO procedure will be implemented. Inspection An independent annualperiodic review/inspection of authorized employees will be conducted to ensure that they are implementing LOTO procedures properly and that they are familiar with their responsibilities under those procedures. The periodic reviews/inspections are intended to identify and correct any deviations observed. An independent authorized employee will perform the periodic reviews/inspections. The work of all authorized employees will be reviewed/inspected by another authorized employee each calendar year. Subcontractors and Host Employers Whenever outside servicing personnel (sub-contractdrs) are to be engaged in activities covered by this section, the employer's lockout or tagout procedures shall be followed. When working for Host Employers, Sancon will be using their Hazardous Energy Control Program if applicable. Training •• All authorized employees will receive the Initial Control of Hazardous Energy course. A refresher Control of Hazardous Energy course will be provided annually for those employees whose job duties require them to continue to perform as an authorized employee. Initial training will include the following topics: • • . Recognition of hazardous 'energy sources . The type and magnitude of energy at the District Methods for isolation and control of the energy Lockout/tagout procedures • • The difference between lockout and tagout • Application of Red Tags Limitations of tags as energy control devices The requirements of Title 8, Section 3314, Cleaning, Repairing, Servicing and Adjusting Prime Movers, Machinery and Equipment • Refresher training will be conducted annually by the Safety Division on topics related to Control of.Hazardous Energy. Records of Training Authorized employee training records include employee name, instructor name, and training 56 1: 1ww:áisi k. &Ic(A549309 - C 17 I%l 7 I 1.1 C 7 a 171%! ••:- : - DATE: PROJECT NAME I BID NUMBER: March 13, 2018 City of Vista — Rehabilitation of 14 Sewr Manholes on Buena Vista Trunk line TO: FROM: City of Vista ' Orion Construction Corporation 1165.E. Taylor Street 2185 La Mirada Drive . Vista, CA 92084-3303 Vista, CA 92081 ATTN: Chris Dzwigalski Eric Kelley, Project Engineer .• CDZWIIGALSKT@ci.vista.ca.us Eric.kelley@ori6nconstruction.com ..Dawings or Data are Submitted: For Approval For Information Number Drawing Supplier & Subject ofSubmittal - Specification of copies Number . Section(s) -. . 'n/a Manhole Interior Epoxy Repair Material (Sancdn : - n/a - Engineering). • ,- (a) We have verified that the material or equipment contained in this subittal- CHECK ONE . meets all the requirements specified or shown (no exceptions) 'This is: .- Submittal -St - . :Ind Submittal (b) We have verified that the material or equipment contained in this submittal ' meets all the requirements specified or shown, except for the following deviations (list deviations or attach letter) -: \ • . -., • : :-- : :-i Submittal # 3 4 Activity # Record float: . - .• -. -' REMARKS: . - .-. . •'•-.- ---'-•--,:;: ;--.• . - ,•• - • - '- .:- •-•••'•., CONTRACT' S AUTHORIZED SIGNATURE: '. • Ke-L-teg - S i.:- • - 2185 La Mirada -Dr, Vista, CA 92024 (760) 597-9660 Phone (760) 597-9661 Fax / i-.. • • •- • . . . •; ••• • • - a S /• S .- / -, . I - .- • ' ,• ,•, I - .. - '• ,. •• - ...-- •• . . - ••S ••-. •t •,•I__ IL SEWER RESTORATION PROD TS L t, SEWER RESTORATION PRODUCT pal I '1 - !2 ' WER RESTORATION PR C prfl -- - F : _QUADE$ SEWER RESTORATI ON:PRO DUCTS V SUBMITTAL PACK ET .I ts AL' 1' At 41' - :I l : Prepared By: James Dugger Fz I ;u,7(ma) SEWER RESTORATION PROD tTS I .. SEWER RESTORATION PRODUCTS • )[ltVt 'rL. 1L4cc4 I I V&1 Nomm, QM Nc / .44 -C-0 Al R, fLTv t.. t>' H 131T*fiY Ij t 4 f, ,, - Prepared By: James Dugger I $ SEWER RESTORATION PRODUCTS Quadex, Inc. 0 4801 Crystal Hill Road North Little Rock, AR 72118 James Dugger 0 Western U.S. Regional Manager - jdugger@guadexonline.com 501-758-8628 Office 216-212-6493 Mobile : www.guadexonline.com History of Quadex V '1 77. QUADEX, INC. created in 1991, manufactures a complete line of V cementitious products and high builds epoxy to restore the structural integrity of manholes, wetwells, pump stations and other related wastewater structures. Our lining products provide a permanent seal against corrosion, infiltration, and exfiltration, and have an installation life of 10 to 50 years in wastewater applications. V V Formulated and designed by QUADEX, INC. with the most advanced ;technology available, our products surpass all other products offered to the industry with regards to structural and flexural strength, • • V permeability, application thickness, and workability. - V To insure the performance of each product, QUADEX, INC., verifies the V results of all in-house studies through extensive independent laboratory V ASTM procedures. QUADEX, INC. has established itself as a leader in V • • this specialized field, unequaled in the Wastewater Rehabilitation V V Industry. • V • V V• V 4801 Crystal Hill Road • North Little Rock, AR 72118 • Phone: (888)831-1650• Fax: (501)758-3814 • Web: quadexonlineVcom V • V L 1Q)I SEWER RESTORATION PthTS SEWER RESTORATION PRODUCTS i*M , - 1 I' I d ¶'r f Tft L -4 Al -4 -' r RATTON PROr -/' / rMUN!CIPAL I-, 1 foe- Irl.4 L$GINEERING' RE FE RE CES I 4•- - i. - - Prepared By:James Dugger / SEWER RESTORATION PRODUCTS Reference List City of Pinellas Park Jim Davis-Sewer Services Coordinator 727-541-0771 Office idavis@pinellas-park.com 605178th Avenue Pinellas Park, FL 33781 Renewable Water Resources Julie Dacus-Project Engineer 864-299-4020 ext 228 Office S julied@rewa.org 561 Mauldin Road Greenville, SC 29607 City of Austin • Louis Cerda-Scheduling Analyst 512-350-8362 Mobile 2600 Webberville Road Austin, TX 78702 • 5; Charlotte-Mecklenburg Utilities Aaron Frazier-Frazier Engineering 704-822-8444 Office S 5100 Brookshire Blvd. Charlotte, NC 28216 Huntsville Water Pollution Control Shane Cook-Sewer Manager 256-883-3719 Office S P.O. Box 308 Huntsville, AL 35804 5 : North Charleston Sewer District Robert Judy-System Maintenance Supervisor 843-764-2641 Office 7225 Stall Road North Charleston, SC 29419 City of Aurora Joe Barsoom-Principal at J Barsoom Consulting Services 303-469-7158 Office V 5070 W 981h Court Westminster; CO 80031 Colorado Springs Utilities Kenneth Keller-Sewer Services 719-448-4800 Office V V - 2855 Mesa Road / Colorado Springs, CO 80904 State of Florida V Department of Transportation Daniel M. Lauricello, P.E. V V V Drainage Engineer V V V 813-975-6137 daniel.lauricello@dot.state.fl.us 12010 N. McKinley Drive, MS 7-800 V V V Tampa, Florida 33612 V City of Memphis, Tennessee V Scott Morgan Head of Engineering V V V 901-576-6720 1 V V scott.morgan@memphistn.gov - V 125 North Main Street V V Suite 620 Memphis, TN 38103 V Little Rock Wastewater Utility V V Oren Noble V - V - Project Engineer V V 501-6881452 V oren.noble@lrwu.com V 11 Clearwater Drive Little Rock, AR 72204 V V V Newnan Utilities Brandon Lovett Director of Water Operations 770-713-3978 blovett@newnanutilities.org 70 Sewell Road Newnan, GA 30263 James Miertschin & Associates S Francisco Cuevas - Project Engineer 512-327-2708 5524 Bee Cave Road Suite D4 Austin, TX 78746 Douglasville WSA Ricky Jacobs Systems Maintenance Superintendent 770-942-6633 rjacobs@ddcwsa.com P.0.1157 Douglasville, GA 30133 Metropolitan Sewer District of St. Louis Kevin Boyd Operations Supervisor ,• • 314-267-8545 kboyd@stlmsd.com S 7500 Mintert Industrial Drive St. Louis, MO 63135 State of Florida Department of Transportation Tim Long Drainage Engineer 727-570-5101 12010 N. McKinley Drive, MS 7-800 5 Tampa, Florida 33612 Orange County FL/Insituform Technologies •• - Brandon Gerber 813-435-8292 i City of Sherwood Charlie Cadie 501-350-6376 Wastewater Supervisor 15210 Kiehl Avenue Sherwood, AR 72120 Crist Engineers Les Price Project Engineer 1405 North Pierce Little Rock, AR 72207 City of Cocoa •• ••• Andrew Dugan Project Engineer S 321-433-8832 375 North Cocoa Blvd Cocoa, FL 32922 City of Southlake Tim Slifka 817-748-8312 1400 Main Street Suite 440 Southlake, TX 76092 S City of Lago Vista Dave Stewart •. 512-392-5111 PO Box 4727 Lago Vista, TX 78645 Lamar Dunn & Associates Greg Jones 865-573-7672 5 3305 Maloney Rd Knoxville, TN 37920 Ladd Environmental Consultants S Larry Whitley 256-845-5315 5 1207 Chitwood Avenue SE Fort Payne, AL 35967 Garver, LLC. Aaron Staliman 501-537-3282 4701 Northshore Drive North Little Rock, AR 72118 McClelland Engineers Dan Beranek - 501-371-0272 900 West Markham Street ' Little Rock, AR 72201 City of Greenville, SC . . . Jessica Chapman . . . . . . 864-467-5708 •: •. 206 South Main Street . . Greenville, SC 29602 Greenwood Metropolitan District . Wayne Daniel . • S . 86429438019 •• 110 Metro Drive Greenwood, SC 29646 Barge Waggoner Sumner & Cannon, Inc. • • • Drew Muirhead • • . • • 615-252-4283 • • • • 211 Commerce Street is • • . • • • Nashville, TN 37201 . S Frazier Engineeing • . . .5 5 Aaron Frazier • . . • S . • 704-822-8444 . S • . . . 5 55 55 6592 Bob White Trail . Stanley, NC 28164 . 555 . . . • S S Gresham Smith & Partners S • / . • Hal Humphrey ••• . 205-298-9200 5 • S . 3595 Grandview Parkway 5 . . .: • .. S • S • - Birmingham, AL 35243 S • City of Winter Garden S S S • • • S S • • Don Cochran S • S • • S •• 55 S • 407-656-4111 5 5 5 5 5 5 5 • S 300 West Plant Road S • • • :• • • . S S S Winter Garden, FL 34787 City of Tallahassee . . Eric Etters 8.50-891-6119 . 408 N. Adams Street Tallahassee, FL 32301 Hydrostructures, PA - Michael Koonce 919-542-5002 126A Commerce Court . .. Pittsboro, NC 27312 0 Metropolitan Sewer District of St. Louis Gene Stinnett 314-768-6200 2350 Market Street St. Louis, MO 6310,3 Hilton Head Public Service District James Hewitt 843-6815525 . 21 Oak Park Place Hilton Head Island, SC 29926 Metropolitan Sewerage District of Buncombe County Ken Stines •• 828-254-9646 0 , 2028 Riverside Drive 0 ' • Asheville, NC 28804 Town of Cary James Mills 0 , 919-319-4544 400 James Jackson Avenue Cary, NC 27513 0 Jacobs Engineering Steve Lindsey O 901-573-4128 0 • 0 ' 0 One Vantage Way 0 0 O , , Suite B-400 O ' ' Nashville, TN 37228 0 , 0 • , 0 0 0 r1 1 0 •O EWERESTORATàN RôDT SEWER RESTORATION PRODUCTS 7p4 — -':.--- - -L -. •1 - 4. d - ' 4 R RSPOUATTON PThTVI - — 5' t. 40 • / RO N I CAL LLATIO N S PFECIFICAT1ON I tFt* •) 0 kit II I I t Q JI I ...- 1 •: : • I Prep-rcd By: lames Dugger STRUCTURE GUARD Corrosion Resistant Epoxy Protective Coating rn QMABILITATIONADEX SEW PRODUCTS DESCRIPTION Quadex Structure Guard is a 100% solids high build epoxy coating system formulated to provide long term protection and, if need be, structural enhancement for manholes, pump stations, pipes, treatment plants, or any wastewater infrastructure subject to high levels of corrosion and/or abrasion. Structure Guard sets fast for a quick return-to-service in the most aggressive and turbulent environments. It's smooth and abrasion resistant finish enhances flow characteristics in pipe lining applications. FEATURES AND BENEFITS 100% Solids, No VOCs Spray applied at 125 mils in a single pass Excellent corrosion and abrasion resistance TYPICAL PERFORMANCE DATA Color Light Green Finish: Very Smooth (Manning Coefficient: .009) Flash Point> 250°F (121°C) Specific Gravity Resin: 1.45 Hardener: 0.97 Dry Service: 30°F - 250°F (121°C) Spill/Splash: 190°F (87.7°C) Immersion Service: 150°F (65.5°C) APPLICATION SYSTEMS Heated Plural Airless Spray Units Minimum Output 5000 psi Product Hose: Min. - Optimum I.D. 0.375 - 0.5 inch CHEMICAL RESISTANCE Acetic Acid 10% Ammonium Hydroxide 25% Brine Water Copper Sulfate Diesel Fuel ° Fatty Acids Gasoline Hydrochloric Acid up to 20% Mineral Spirits Potassium Hydroxide 50% Crude Oil Caster Oil Ethylene Glycol Sodium Chloride Sodium Hydroxide 50% Sulfuric Acid 75% Sewage (Hydrogen Sulfide) Alkalis Fresh and non-potable water Wine Ethanol Structure Guard passes ASTM F1216 chemical resistance requirements. MULTIPLE COATS \ Good coating practice generally requires 2 or more coats to attain finished thickness. Second and subsequent coats must be applied before the previous coat has completely cross-linked, typically 12 hours © 72°F (higher temperatures/humidity will shorten this window). If coating after re-coat window, brush blast before applying the next coat. Before reblasting, clean and dry surface thoroughly to remove all contamination, including amine blush or condensation. Small areas may be abraded by sanding or wire brushing. The same requirements apply when overlapping seams of adjacent coating sections to create a continuous protective film. If the coating surface to be overlapped at the seam cannot be brush blasted, use a non-impact means as power brushing or sanding to create a mechanical profile. PACKAGING Structure Guard is available in 5 gallon pales and 55 gallon drums YIELD Structure Guard will yield an approximate theoretical coverage of 20 sq. ft per gallon © 80 mils thickness. Actual surface coverage - will depend on substrate porosity and roughness. Good painting practices suggest application of two coats for quality assurance. A wet film thickness gauge may be used to determine actual coating coverage. CURE TIME (at 70°F or 21°C) Re-coat Window 8 hours Light Loading 6 - 12 hours Immersion (Aqueous) Service 6 - 12 hours Full Chemical Cure - 7 days POT LIFE 40°F (4°C) 1 hour 75°F (24°C) 35 minutes 92°F (33°C) 20 minutes 4801 Crystal Hill Road North Little Rock, AR 72118 Phone: (501) 758-8628 Toll Free: (888) 831-1650 ...........- / SURFACE PREPARATION Coating performance is largely determined by the degree of surface preparation ... More is Better. CONCRETE & MASONRY substrates must be prepared in a manner that provides a uniform, sound, clean, neutralized surface with sufficient profile suitable for the specified coating. The substrate must be free of all contaminants, such as oil, grease, rust, scale or deposits and have a surface profile equivalent to a CSP2 to CSP5 in accordance with ICRI Technical Guideline No. 03732. This can generally be achieved by abrasive blasting, shot blasting, high pressure water cleaning, water jetting, acid etch, hot water/steam cleaning or a combination of methods. STEEL surfaces may require "Solvent Cleaning" (SSPC-SP 1) to remove oil, grease and other soluble contaminants. Chemical contaminants may be removed according to SSPCSP 12/NACE No. 5. Identification of the contaminants along with their concentrations may be obtained from laboratory and field tests as described in SSPC-TU 4" Field Methods for Retrieval and Analysis of Soluble Salts on Substrates." Surfaces to be coated should then be prepared according to SSPC-SP 5/NACE NO.1 "White Blast Cleaning" for immersion service or SSPC-SP lO/NACE No. 2. "Near White Blast Cleaning" for all other service. In certain situations, an alternate procedure may be to use high (>5,000 psi) or ultrahigh (>10,000 psi) pressure water cleaning or water cleaning with sand injection. The resulting anchor profile shall be 2.5-5.0 mils and be relative to the coating thickness specified. Physical Properties Gel Time, 150 grams at 25°C ASTMD2471 18 minutes Tensile Strength ASTM 0638 7,300 psi Elongation ASTM D638 1.50% Flexural Strength ASTM D790 11,500 psi Flexural Modulus ASTM D790 590,000 psi Compressive Strength ASTM D695 12,000 psi Shore D Hardness ASTM b2240 82 Taber Abrasion, CS 17 Wheel ASTM 04060 <100 mg loss (I kg load /1000 cycles) Adhesion to Concrete ASTM D4541 >2000 psi (substrate failure) Adhesion to Blasted Steel ASTM D4541 >3000 psi Water Vapor Transmission ASTM D1651 . 3.0 grams / m2 (24 hours) Water Absorption ASTM 0570 • 0.15% Volatile Organic Content ASTM 02580 N/A (<10 grams I liter) Physical properties were evaluated on compounds cured for5 days at 25°C / 50% relative humidity. WARRANTY: .. Quadex warrants its products to be free of defects in material and workmanship. Within one year from purchase, if any Quadex product is proven defective, Quadex will replace said product or refund its purchase price, at Quadex's sole discretion. • Quadex's obligation shall be limited solely to such replacement or refund. There are no other warranties by Quadex expressed or implied. There is no warranty if Quadex products are used contrary,to Quadex's written directions. ,. . / QUADEX MANHOLE RESTORATiON SYSTEMS QUADEX STRUCTURE RESTORATION & PROTECTION RaArIA I ILIIA I I ArI,'II IVIM I r—RIAL5 INS I ML.I..M I UJIl 5PECIFICA.1 IIJIl 1.0 GENERAL 1.1 These specifications are intended to set a standard of quality and design for the application of cementitious and/or epoxy materials used in the rehabilitation of deteriorated masonry, concrete or metal structures; and protection of new structures. 1.2 REFERENCES ASTM D638 - Tensile Properties of Plastics. ASTM D790 - Flexural Properties of Unreinforced and Reinforced Plastics. - ASTM D695 - Compressive Properties of Rigid Plastiós. ASTM D4541 - Pull-off Strength of Coatings Using a Portable Adhesion Tester. ASTM D2584 - Volatile Matter Content. ASTM D543 - Resistance of Plastics to Chemical Reagents. ASTM C109 - Compressive Strength Hydraulic Cement Mortars. ACI 506.2-77 - Specifications for Materials, Proportioning, and Application of Shotcrete. 1. ASTM C579 - Compressive Strength of Chemically Setting Silicate and Silica Chemical Resistant Mortars. SSPC SP-13/NACE No. 6 - Surface Preparation of Concrete ASTM - The published standards of the American Society for Testing and Materials, West Conshohocken, PA. NACE - The published standards of National Association of Corrosion Engineers (NACE International), Houston, TX. NASSCO - National Association of Sewer Service Compaines, Marriottsville, MD - Manhole Assessment Condition Program (MACP) SSPC - The published standards of the Society of Protective Coatings, Pittsburgh, PA. / .5. 1.3 SUBMITTALS - A. Product Data: Technical data sheet on each product used. Material Safety Data Sheet (MSDS) for each product used. Copies of independent testing performed on the coating product indicating the product meets the requirements as specified herein as well as documentation showing proof that the material has been used in a corrosive environments containing H2S for at least 5 years. 2.0 DEFINITIONS 2.1 The term "approved" shall mean that the proposed material shall meet or exceed each of the performance criteria set forth in this specification. Manufacturers and vendors of various name brand materials must submit proof that any proposed material will meet the guidelines and requirements of this specification. Material approvals shall be made by the engineer no less than two weeks prior to bid date. 3.0 MATERIAL SELECTION & DESIGN CRITERIA 3.1 Condition A: Low hydrogen sulfide environments (pH > 3.0). Substrate shall receive a minimum of 1" cementitious lining material manufactured from Type II Portland cement, and enhanced with silica fume. Materials shall contain poly-fiber reinforcement, chemical admixtures, and siliceous aggregates. Approved material shall be Quadex QM-1s Restore as manufactured by Quadex. 3.2 Condition B: Medium to high hydrogen sulfide environments (pH 1.0 - 2.0). Substrate shall receive a minimum of 1" cementitious lining material manufactured from 100% pure calcium aluminate cement enhanced with high- • density chemically stable aggregates; or geopolymer mortar lining materials manufactured from pozzolanic materials of industrial byproducts enhanced with a monocrystalline quartz aggregate. Materials Shall. contain poly fiber reinforcement to help mitigate shrinkage. Approved materials shall be Quadex Aluminaliner as manufactured by Quadex (pH >1= 2.0) or Quadex GeoKrete(pH >1= 1.0). 3.3 Condition C: Severe hydrogen sulfide environments (pH >1= 1.0) and substrate corrosion > 0.125 inch. Substrate shall receive a minimum I" • geopolymer lining material manufactured from pozzolanic materials of • industrial byproducts enhanced with a monocrystalline quartz aggregate. Approved geopolymer material, shall be Quadex GeoKrete or pre-approved • equal. '- 3.4 Condition D: Hyper severe hydrogen sulfide environments (pH < 1.0) with severe turbulence and substrate corrosion > 0.125 inch. Substrate shall receive a composite system consisting of a minimum 1/2" cementitious lining material manufactured from compatible Portland, calcium aluminate or geopolymer cement with a 125 mil topcoat of 100% solids epoxy lining material containing no VOC's or isocyanates. Approved cementitious material shall be from the same manufacturer as the epoxy topcoat. The approved epoxy material shall be Quadex Structure Guard or equal. 3.5 Condition E: New construction with anticipated harsh hydrogen sulfide environments (pH < 2.0) or substrate corrosion < 0.125 inch and harsh hydrogen sulfide environments (pH <2.0). Substrate shall receive a minimum of 125 mils of 100% solids epoxy lining material containing no VOC's or isocyanates. Approved epoxy material shall be Quadex Structure Guard. 4.0 APPROVED MATERIALS When more than one product is used in composite with other(s), all materials shall be from the same manufacturer. 4.1 - Infiltration Control All fast setting materials furnished shall be designed to be applied in dry powder form, with no prior mixing of water, directly to active leaks under hydrostatic pressure in manholes or related structures. Materials shall consist of rapid setting cements, siliceous aggregates, and various accelerating agents. Material shall not contain chlorides, -gypsum, or metallic particles. Approved infiltration control material shall be Quadex Quad-Plug as manufactured by Quadex. - A. Specifications: Infiltration Control Materials - Compressive Strength (ASTM C109) - 30mins: 18510 psi Bond Strength (ASTM C321) - - 28-Day: >80 psi Set Time 30 seconds - - - - 4.2 Invert Repair and Patching All material furnished shall be designed to fill large voids in structure walls and to repair or reconstruct inverts where no hydrostatic pressure exists. Material shall consist of rapid setting cements, NSG aggregates, and various accelerating agents. Material shall not contain chlorides, gypsum, or metallic particles. Approved invert repair and patching material shall be Quadex Hyperform or Structure Guard RS Patch as manufactured by Quadex. r I. Approved material shall exhibit the following minimum physical properties: Compressive Strength (ASTM C109) 30 mins: >1200 psi 1 hour: >2500 psi 1 day: >4000 psi Bond Strength (ASTM C882) 28-Day: >3000 psi Shrinkage (ASTM C666) 0% 4.3 Cementitious Lining Materials All cementitious lining materials shall be specifically, designed for the rehabilitation of manholes,, pipes, tunnels and other related wastewater structures. Liner materials shall be cement based, poly-fiber reinforced, shrinkage compensated, and enhanced with chemical admixtures and siliceous aggregates. Liner materials shall be mixed with water per manufacturer's written specifications and applied to - inch thickness using equipment specifically designed for either low-pressure spray or centrifugal spin casting application of cement mortars. All cement liner materials must be capable of a placement thickness of 1/2" to 4" in a one pass monolithic application. A. Portland cement Portland cement materials shall be manufactured from Type II Portland cement and enhanced with silica fume and high-density . chemically stable aggregates. Materials must resist corrosion when placed in an environment capable of producing a maximum substrate pH level of 3.0. Approved material shall be Quadex QM-ls Restore as manufactured by Quadex, or "pre-approved" equal. Approved material shall exhibit the following 28-day minimum physical properties: Compressive Strength (ASTM C109) >9,000 psi Flexural Strength (ASTM C293), >1,250 psi ; H Bond Strength (ASTM C882) >2,500 psi Permeability (AASHTOT-277) Not to exceed 350 coulombs Freeze-Thaw (ASTM C666) No damage in minimum 300 cycles Material Wet Density Minimum 127 +/-5 PCF B. Calcium Aluminate Calcium Aluminate materials shall be manufactured from 100% pure calcium-aluminate cement and enhanced with silica fume and high- density chemically stable aggregates. Materials must resist corrosion when placed in environments capable of a substrate pH level of 2.0 or greater. Approved material shall be Quadex Aluminaliner as Manufactured by Quadex, or "pre-approved" equal. Approved material shall exhibit the following 28-day minimum physical properties: Compressive Strength (ASTM C109) >9,000 psi Flexural Strength (ASTM C293) >1,600 psi C: Bond Strength (ASTM C882) >2,500 psi D. Permeability (AASHTO T-277) Not to exceed 350 coulombs. E. Freeze-Thaw (ASTM C666) No damage in minimum 300 cycles F. Material Wet Density . Minimum 127 +1-5 PC • Geopolymer Mortar lining materials Geopolymer mortar lining materials shall be manufactured from pozzolanic materials of industrial byproducts enhanced with a monocrystalline quartz aggregate. Recycled byproducts shall constitute a minimum of 60%-of the product binder. Materials must resist corrosion when placed in a sewer environment capable of producing a substrate pH levels of 1.0 or greater. Product must lose no more than 1.5% mass vhen subjected to ASTM C 267 in the 8 Week Acid Immersion Test. Approved geopolymer mortar shall be Quadek GeoKrete as manufactured by Quadex, or "pre-approved" equal. Approved material shall exhibit the 28-day minimum physical properties: A. Compressive Strength (ASTM C109) c / I >8,000 psi - Flexural Strength (ASTM C293) >750 psi Bond Strength (ASTM C882) >2,000 Permeability (AASHTO T-277) Not to exceed 300 coulombs Freeze-Thaw (ASTM C666) No damage in minimum 300 cycles Material Wet Density Minimum 127 +/-5 PCF 4.4 Protective Coating Polymer protective coating and lining materials shall be specifically designed for protecting manholes and other related wastewater structures from severe hydrogen sulfide environments. Liner materials shall be 100% solids epoxy containing no VOC's or isocyanates and capable of building 150 mils in a single application. All epoxy lining materials shall be applied to a minimum of - mils only by heated plural component equipment as approved by the manufacturer. Approved material shall be Quadex Structure Guard or preapproved equal. Epoxy materials shall meet the following minimum physical properties: Tensile Strength ASTM 0638 7,000 psi Flexural Strength ASTM D790 11,000 psi Compressive Strength ASTM 0695 12,000 psi : Shore D Hardness ASTM 02240 83 Elongation 1.50% Taber Abrasion ASTM4060 1000 gm load @ 1000 cycles <100mg loss 5.0 CEMENTITIÔUS REHABILITATION 5.1 Structure Cleaning and Preparation :. Surfaces to be coated shall be cleaned sufficiently to provide a sound clean, uniform and pH neutralized surface suitable for the specified coating product(s). Excessive debris, sediment, root intrusion or other foreign materials which may impact the effectiveness of the surface preparation process shall be removed prior to the commencement thereof. Offset structural components, lids, covers, frames, etc. shall be repaired, replaced, or reset prior to the commencement of surface preparation. External soil/fill voids shall be remediated and/or, stabilized by replacement or injection of stabilizing grout as determined appropriate by the engineer. .1 Oils, grease, incompatible existing coatings, waxes, form release, curing compounds, efflorescence, sealers, salts, or other contaminants which may affect the performance and adhesion of the coating to the substrate shall be removed in accordance with SSPC- SP 1 - Solvent Cleaning or other suitable method. Choice of surface preparation method(s) should be based upon the condition'of the structure and concrete or masonry surface, potential contaminants present, access to perform work, and the required cleanliness and profile of the prepared surface to receive the repair and/or coating product(s). Surface preparation method, or combination of methods, that may be 2 used include high-pressure water cleaning, water jetting, abrasive blasting, shotblasting, grinding, scarifying, detergent water cleaning, steam or hot water cleaning and others as referenced in industry accepted standards such as: SSPC SP-13/NACE No. 6 Surface Preparation of Concrete, ASTM 0-4258 Standard Practice for Surface Cleaning Concrete for - Coating and ASTM-D-4259 Standard Practice for Abrading Concrete, 1. ICRI Technical Guideline No. 03732 Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer Overlays. NACEISSPC Standards for the surface preparation of steel. Resulting surface profile of the prepared concrete substrate shall be (as described in ICRI Technical Guideline No. 03732): i. For application of cementitious materials; at least a CSP2 ii. For application of coating prodUcts: at least a CSP4. Alf loose debris materials resulting from the cleaning of the structure shall be removed prior to application of the cement based coating. All loose or defective brick, grout, ledges, steps and protruding ledges shall be removed to provide an even surface prior to application of cement based coating. 5.2 Sealing Active Leaks ,. The work consists of hand applying a dry quick-setting cementitious mix designed to instantly stop running water or seepage in all types of concrete and masonry structures. The applicator shall apply material in accordance with manufacturer's recommendations and following specifications. A. The area to be repaired must be clean and free of all debris per the guidelines set forth in 5.1. / Once cleaned, prepare crack or hole by chipping out loose material to a minimum depth and width of% inch. With gloved hand, place a generous amount of the dry quick-setting cementitious material to the active leak, with a smooth fast motion, maintaining external pressure for 30 seconds, repeat until leak is stopped. Proper application should not require any special mixing of product or special curing requirements after application. 5.3 Invert Repair and Patching The work consists of hand mixing and applying a rapid setting, high early strength, non-shrink patching material to fill all large voids and repair inverts prior to spray lining of the structure. For pipe or manhole invert repairs, flow must be temporarily restricted prior to cleaning. The area to be repaired must be cleaned and free of all debris per the guidelines set forth in Section 5.1. Mix water shall be clean potable water and require no additives or admixtures for use with cementitious patching materials. Cemertitious material shall be mixed in a mortar tub or 5-gallon pail with water per manufacturer's specifications. Material should be mixed in small quantities, to avoid setting prior to placement in voids or inverts. Once mixed to proper consistency, the materials shall be applied to the invert or void areas by hand or trowel. In invert applications, care should be taken to not apply excessive material in the channel, which could restrict flow. Once applied, materials should be smoothed either by hand or trowel in order to facilitate flow. Flows in inverts can be reestablished within 30 minutes of material placement. 5.4 Application of Cementitious Liner The work consists of spray applying and/or centrifugally spin-casting the specified liner material to the inside of an existing structure. The necessary equipment and application methods to apply the liner materials shall be only as approved by the material manufacturer. Material shall be mixed in accordance with manufacturer's specifications to proper consistency, then the materials shall be pumped through a material plaster hose for delivery to the appropriate and I or selected application device. '-V In brick, block, rock, concrete and corrugated metal pipelins, tunnels and manholes with deteriorated surfaces, material shall be applied to specified thickness, but no less than one (1) inch. In precast manholes, materials may be applied no less than one half (1/2) inch to 'help ensure proper curing. Application on all pre-cast/poured-in-place manholes shall occur after preparing surfaces to a Concrete Surface Profile (CSP) of 19 or greater. Material shall be applied to the bench and invert area in such a manner as to provide'for proper drainage without ponding and to compensate for abrasion. Material must be applied only when surfaces are damp but with no visible water dripping or running. A. Hand Spray Application - L Material hose shall be coupled to a low-velocity spray application " nozzle. Pumping of the material shall commenceand the mortar shall be atomized by the introduction of air at the nozzle, creating a low-velocity spray pattern for material application. Spraying shall be performed by starting at the bottom of the structure and progressing up the wall Material shall be applied to a specified uniform minimum thickness no less than - inch(es). Material shall be applied to the bench area in such a manner as to pràvide for proper drainage without ponding and accounting for anticipated abrasion. Troweling of materials (if specified) shall begin immediately following the spray application. Initial troweling shall be in an upward motion, to compress the material into any voids within the structure walls. Precautions should be taken not to over trowel. V. Once troweling has been completed the applied liner shall be brushed to remove trowel marks and to break up the latent surface brought about by trowelling. Brushing should be in the horizontal plane and as with troweling do not over work the lining material. B. Centrifugal Application Spin-cast unit shall be approved by the material manufacturer. Motor torque and application process shall be sufficient to evenly apply lining materials within an 8 foot diameter or smaller structure. Robotic insertion/extraction equipment and speeds shall be calibrated to the structure diameter to ensure uniform application to specified thickness. Material hose shall be coupled to the spin-cast unit. The spin-cast unit shall then be positioned within the center of the horizontal or vertical structure. L Vertical Structures: Initially locate the spinner at either the top of the manhole chimney or the lowest point corresponding to the junction of the manhole bench and walls. The spin-cast unit shall then be initialized, and pumping of the material shall commence. As the mortar begins to be centrifugally cast evenly around the interior of the structure, the rotating applicator head may be cycled up and down in rough, non-uniform vertical structures at a controlled I,. retrieval speed conducive to providing a uniform material thickness on the structure walls. Horizontal Structures: Initially locate the spinner at the far end of the structure and calibrate equipment to pull back at predetermined speed calibrated to design thickness per application coat. Allow to cure sufficiently to withstand weight of application equipment for subsequent pass(es), then initiate subsequent application pass(es) to specified thickness. Some structures with isolated extraordinary deterioration may require hand spraying of such areas to recontour surfaces prior to initial spincast coat. C. Curing Curing begins immediately after mixing and proper material application. It is - important that the structure be isolated from sunlight and dry outside air as soon as possible but no more than 10 minutes after troweling is complete to avoid moisture loss in the material. Contractor shall place a cover sheet of plastic sheeting between manhole frame and cover or tunnel/pipe terminations to prevent moisture loss. Applications should not occur in direct sunlight. When low or no flow conditions exist within vertical structures, additional measures may be required such as placing plastic sheeting underneath the lid/cover. To help ensure proper cure, contractor may alternately apply Quadex Quad Cure curing agent to the lined surface or employ misters or other humidity enhancing methods to keep humidity levels sufficiently high for proper cure. Material shall not be applied during freezing weather conditions. Material shall not be placed when the ambient temperature is 37 degrees Fahrenheit and falling or when the temperature is anticipated to fall below 32 degrees Fahrenheit within 24 hours. 6.0 EPDXY REHABILITATION 6.1 Certifications To ensure contractor proficiency in appling specified epoxy products, the contractor and his equipment shall be certified by the manufacturer. Furthermore, certification of contractor and equipment must be by a NACE Certified Inspector holding valid and current NACE certification at time of inspection; or a NASSCO MACP certified inspector. Written documentation shall be provided to contractor and Project Engineer/ owner before any work commences. 6.2 Coating Application Equipment - A. Manufacturer approved heated plural component spray equipment. B. Hard to reach areas, primer application, and touch-up may be performed using hand tools. 6.3 Pre-Application Inspections Unless prior approval has been received from the manufacturer new Portland cement concrete structures shall have a minimum cure of 28 days. Should earlier coating be required, coating product manufacturer shall recommend specifications including appropriate cure assessment testing and use of speciality primers and sealers. All active flows shall be plugged or diverted away from all surfaces to be coated. Temperature of the surface to be coated should be maintained between 40 and 120 deg F. Specified surfaces should be shielded to avoid exposure of direct sunlight or other intense heat source. Where varying surface temperatures do exist, copting installation should be scheduled when the temperature is falling versus rising. Prior to commencing surface preparation, Contractor shall inspect all surfaces specified to receive the coating and notify Owner, in writing, of any noticeable disparity in the site, structure or surfaces which may interfere with the work, use of materials or procedures as specified herin. V 6.4 Surface Preparation V. V Concrete and/or mortar damaged by corrosion, chemical attack or other means of degradation shall be removed so that only sound substrate remains. Oils, grease, incompatible existing coatings, waxes, form release, curing compounds, efflorescence, sealers, salts, or other contaminants which- may affect the performance and adhesion of the coating to the substrate shall be removed. V Choice of surface preparation method(s) should be based upon the condition of the structure and concrete or masonry surface, potential contaminants present, access to perform work, and required cleanliness and profile of the prepared surface to receive the coating product(s). Suface preparation method, or combination of methods, that may be used include high pressure water cleaning, water jetting, abrasive V blasting, shotblasting, grinding, scarifying, detergent water cleaning, hot water blasting and others as referenced in NACE No. 6/SSPC SP-13 Surface Preparation of Concrete. Whichever method(s) are used, the V work shall be performed in a manner that provides a uniform, sound clean neutralized surface suitable for the specified coating product(s). Resulting surface profile shall be at least a. CSP 4 in accordance with lCRl Technical Guideline No. 03732. Prior to the application of the coating prodcut, all infiltration shall be eliminated by use of appropriate repair material(s), such as hydraulic cements and/or repair mortars per Section 5.2. Consult with manufacturer when compatiblity issues arise. 6.5 Application of Repair and Resurfacing Products Areas where rebar has been exposed shall be repaired by an abrasive blast according to SSPC-SP10 prior to applying specified primer, as recommended by the manufacturer or in accordance with the Project Engineer's recommendations. Repair products may be used to fill voids, bugholes, and other surface defects which may affect the performance or adhesion of the coating product(s). Resurfacing products shall be used to repair, smooth or rebuild surfaces with rough profiles to provide a concrete or masonry substrate suitable for the coating product(s) to be applied. These products shall be installed to minimum thickness as recommended within manufacturers published guidelines. Should structural rebuild be necessary, these products shall be installed to a thickness as specified by the Project Engineer. Repair and resurfacing products shall be handled, mixed, installed and cured in accordance with manufacturer guidelines setforth in Section . 5.3. - All repaired or resurfaced surfaces shall be inspected for cleanliness and suitability to receive the coating product(s). 6.6 Application of Epoxy Coating Product(s) Application pyocedures shall conform to the recommendations of the coating product(s) manufacturer, including environmental controls, product handling, mixing, application equipment and methods. Spray equipment shall be specifically designed to accurately ratio and apply the coating product(s) and shall be in proper working order. Contractors qualified in accordance per Section 5.1 of these specifications shall perform all aspects of coating product(s) installation. Prepared surfaces shall be coated via spray application of the coating product(s) described, herein unless otherwise recommended by the coating product manufacturer. Coating thickness shall be in relation to the profile of the surface to be coated as recommended by the coating product manufacturer. In all cases the coating product(s) shall be applied to a minimum dry film thickness of 80 mils to surface profiles of CSP-4 to CSP-6 or 125 mils minimum DFT to surface profiles of CSP-7 or greater. Subsequent topcoating or additional coats of the coating product(s) shall occur within the product's recoat window or 24 hours which ever is less. Additional surface preparation procedures will be required if this recoat window is exceeded. Coating product(s) shall interface with adjoining construction materials/components throughout the structure to effectively seal and protect substrates from attack by corrosive elements and to ensure the effective elimination of inflitration into the sewer system. 1. Procedures and materials necessary to effect the interface between dissimilar materials and the coating product shall be as recommended by the coating product(s) manufacturer. -j Sewage flow shall be stopped, bypassed or diverted as necessary for application of the coating product(s) to the invert/flowline. Visual inspection shall be made by the Project Engineer and/or Inspector as soon as the epoxy has set (2-4 hours at 60 deg F). Any deficiencies in the finished coating shall be marked and repaired by Contractor according to the procedures set forth herein. Sewage flow may be returned to full operational service as soon as the final inspection has taken place. 7.0 QUALITY CONTROL - CEMENT The quality and performance of the material and the workmanship of the applicator shall be maintained by one or more of the following measures to be determined and specified by the engineer or owner. 7.1 Visual Inspection All structures will be visually inspected for cracks, bug holes, and unfinished surfaces by a NASSCO MACP certified inspector, or equal. 7.2 Performance Testing Vacuum Testing - 25% (suggested) of the manholes with flows low enough to halt the flow long enough for a vacuum test shall be vacuum tested. All pipes entering the manhole must be sound (not cracked) and should be plugged, taking care to securely place the plug from being drawn into the manhole Lined mains most have pipe seal preventing leaks in annular space with original pipe. A vacuum pump apparatus shall be placed onto the manhole ring and sealed to the structure in accordance with the pump manufacturers' recommendations. A vacuum pump of ten (10) inches of mercury shall be drawn and the vacuum pump shut off. With the pressure relief valves closed, the time shall be measured for the vacuum to drop to (9) inches. The following are minimum allowable test times for manhole acceptance at the specified vacuum drop. Manhole Depth Time (Seconds) (Feet) 48" Diameter 60' Diameter 72" Diameter 4 10 13 16 8 20 26 32 12 30 39 48 16 . 40 52 64 .20 50 65 80: 24 60 78 96 For each additional 2 ft. depth add: 5 6.5 8 - Exflltration Testing As an option for vacuum testing, 25% of the manholes with flows low enough to halt the flow long enough for an exfiltration test shall be so tested. Incoming and outgoing sewer and service lines shall first be plugged. An optional soaking period of up to one (1) hour will be allowed if bypassing of the sewage is not required or has been provided for. At the end of this optional soaking period, the manhole shall be completely filled with water to the manhole cover frame and the test initiated. For manholes that are 0-6 feet in depth, if water loss is less than one (1) inch or less in five (5) minutes, the manhole reconstruction shall be deemed acceptable. For manholes that are over six (6) feet in depth, if water loss is one (1) inch' plus 1/87inch for each additional foot of depth or less in five (5) minutes, the manhole reconstruction shall be deemed acceptable. Should the drop in the water level exceed the previously stated test standard, the manhole shall be deemed a failed installation. j C. Material Testing One 2 x 2 inch sample cube shall be taken for every 56 bags of material used. Samples shall be sprayed from nozzle, identified, and sent to an independent test. laboratory for compression strength testing as described in ASTM C-109 and shall have a minimum average of the strengths set fdrth in Section 3.3. 8.0 QUALTIY CONTROL - EPDXY The quality and performance of the material and the workmanship of the applicator shall be maintained by one or more of the following measures to be determined and specified by the engineer or owner. A. During application, a wet film thickness gauge, meeting ASTM 04414 - Standard Practice for Measurement of Wet Film Thickness of Organic Coatings by Notched Gages, shall be used. Measurements shall be taken, documented and attested to by Contractor for submission to Owner. B. High voltage holiday detection for coating systems installed in corrosive environments, when it can be safely and effectively employed, shall be performed to ensure monolithic protection of the substrate. After th6 coating product(s) have cured in accordance with manufacturer recommendations, all surfaces shall be inspected for holidays in accordance with NACE 5P0188- 2006 Discontinuity (Holiday) Testing of New Protective Coatings on Conductive Substrates or ASTM 04787 Standard Practice for Continuity Verification of Liquid or Sheet Linings Applied to Concrete Substrates. All detected holidays shall be marked and repaired according to the coating product(s) manufacturer's recommendations. Test voltage shall be a minimum of 100 volts per mil of coating system thickness. Detection of a known or induced holiday in the coating product shall be confirmed to ensure proper operation of the test unit. All areas repaired shall be retested following cure of the repair material(s). In instances where high voltage holiday detection is not feasible a close visual inspection shall be conducted and all possible holidays shall be marked and repaired as described above. Documentation of areas tested, equipment employed, results and repairs made shall be submitted to the Owner/Engineer by Contractor. [Optional - Adhesion Testing is a destructive test method and should be used in moderation as an evaluation tool.] Adhesion of the coating system to the substrate shall be confirmed in a minimum of 10% of the manholes coated, or for large structures once every 1000 square feet of coated area. Testing shall be conducted in accordance with ASTM D7234 Pull-Off Adhesion Strength of Coatings on Concrete Using Portable Pull-Off Adhesion Testers. Owner's representative shall select the manholes or areas to be tested. For each test manhole a minimum of three 20 mm dollies shall be affixed to the coated surface; one at the cone area, one at the mid section and one near the bottom of the structure. For larger structures a minimum of three 20 mm dollies shall be affixed to the coated surface at random locations within each 1000 square foot area or as otherwise agreeded upon. The adhesive used to attach the dollies to the coating shall be rapid. setting with tensile strengths in excess of at least twice the anticipated failure point (generally at least 1000 psi) and permitted to cure in accordance with manufacturer recommendations. The coating and dollies shall be adequately cleaned and prepared to receive the adhesive. Failure of the dolly adhesive shall be deemed a non-test and require retesting. Prior to performing the pull test, the coating shall be scored to the substrate, or within 10 mils of the substrate surface, by mechanical means without disturbing the dolly or coating system bond within the test area. Two of the three adhesion pulls in each test area shall exceed 200 psi and shall include substrate adhered to the back of the dolly or no visual signs of the coating product in the test hole. Pulls tests with results between 150 and 200 psi may be acceptable if more than 50 percent of the substrate in the test area is adhered to the dolly. K. Should a structure, or area, fail to achieve two successful pulls as described above, additional testing shall be performed at the discretion of the Owner or Project Engineer. Any areas detected to have inadequate bond strength shall be evaluated by the Project Engineer. Further bond tests may be performed in that area to determine the extent of potentially deficient bonded area and repairs shall be made by Contractor All adhesion testing shall be performed by qualifed personnel using calibrated equipment as specified by the applicable ASTM standard(s). All adhesion testing shall be documented and submitted in a consistent format detailing location, test values description of the failure point/mode, scoring method employed, adhesive used, cure time of coating and adhesive and other data as deemed necessary by the owner/engineer. N. All a adhesion test locations shall be repaired by the Contractor at no cost to the Owner. Visual inspection shall be made by the Project Engineer and/or Inspector. Any deficiencies in the finished coating effecting the perfomance of the coating system or the operational functionality of the structure shall be marked and repaired according to the recommendations of the coating product(s) manufacturer. The municipal sewer system may be returned to full operational service as soon as the final inspection has taken place and all coating materials have . been adequately cured according to the coating product(s) manufacturer's recommendations. I 9.0 WARRANTY 9.1 Product manufacturers shall warrant all materials to be free of defects, product design, and workmanship for a period of one year from date of purchase. Manufacturer will provide replacement materials for any product proven to be defective when applied in accordance with manufacturer's recommendations. Manufacturer's obligation shall be limited solely to product replacement. I. \ I •, -. •• / •• QUADEX MATERIAL(S) SELECTION I DESIGN CRITERIA Condition A: Low to mild hydrogen sulfide environments (pH > 3.0). Brick substrate shall receive a minimum of 1" cementitious lining material manufactured from Type Il Portland cement, and enhanced with silica fume. Materials shall contain poly-fiber reinforcement, chemical admixtures, and siliceous aggregates. Approved material shall be Quadex QM-1s Restore as manufactured by Qüadex, Inc. Condition B: Medium to high hydrogen sulfide environments (pH 1.0 - 2.0). Substrate shall receive a minimum of 1" cementitious lining material manufactured from 100% pure calcium aluminate cement enhanced with high-density chemically stable aggregates; or geopolymer mortar lining materials manufactured from pozzolanic materials of industrial byproducts enhanced with a monocrystalline quartz aggregate. Materials shall contain poly fiber reinforcement to help mitigate shrinkage Approved material shall be Quadex Aluminaliner as manufactured by Quadex, Inc. Condition C: Severe hydrogen sulfide environments (pH >1= 1.0) and substrate corrosion > 0.125 inch. Substrate shall receive a minimum 1" geopolymer lining material manufactured from pozzolanic materials of industrial byproducts enhanced with a monocrystalline quartz aggregate. Approved material shall be Quadex GeoKrete as manufactured by Quadex, inc.. Condition D: Hyper severe hydrogen sulfide environments (pH < 1.0) with severe turbulence and substrate corrosion > 0.125 inch. Substrate shall receive a composite system consisting of a minimum 1/2" cementitious lining material manufactured from compatible Portland, calcium aluminate or geopolymer cement with i 125 mil topcoat of 100% solids epoxy lining material containing no VOC's or isocyanates. Approved cementitious material shall be from the same manufacturer as the epoxy topcoat. Approved cementitious material shall be either Quadex Aluminaliner or Quadex QM-1s Restore and approved epoxy material shall be Quadex Structure Guard. Condition E: New construction with anticipated harsh hydrogen sulfide environments (pH <2.0) or substrate corrosion <0.125 inch and harsh hydrogen sulfide environments (pH <2.0). Substrate shall receive a minimum of 125 mils of 100%solids epoxy lining material containing no VOC's or isocyanates. Approved epoxy material shall be Quadex Structure Guard. ( 4801 Crystal Hill Road• North Little Rock, AR 72118 4 Phone: (888)831-1650 • Fax: (501)758-3814 • Web: quadexonline.com SEWER RESTORATION PROD CTS H _ :- DJ - - L SEWEr RESTORATION PRODUCTS r*. ov :- -.- 4h ' Oil ri I -' --:-_ - __4i1EAli / PRO-DuC-"--,T,- -~MATE RIAL Plik SAFgTrDATA $HE ET I vw'; -,z r~ ;L - I . It V : .1 II • - • • - P-epared B: James Dugér North Little Rock, AR 72118 Phone: (501)758-8628 QUADEX Fax: (501) 758-3814 - striicture uuara epoxy MATERIAL SAFETY DATA SHEET ObTTUAbEÔ 3 1 Product and Company Identification Material name SG-2500 Series Part A • Version # . 01 Revision date 02-07-2012 CAS# Mixture -• , Product use Protective Coatings Synonym(s) SG 2510 * Manufacturer Quadex .•;_, .- Address P0 Box 1639 Jackson, MS 39215-1639 Contact Name Mary Ellen Snow -'. " • ,' E-Mail .' mary.snow@ergon.com * Hours of Operation 8:00AM - 5:00PM • . ERGON General Assistance 800-222-7122 - 24 Hour Emergency CHEMTREC: North America 1 (800) 424 9300 International 1 (703) 527 • 3887 , 2 Hazards Identification OSHA regulatory status This product is considered hazardous under 29 CFRr 1910 1200 (Hazard - Communication), • Potential health effects . - ..• ' Routes of exposure . . Inhalation. Skin contact. Eye contact . Eyes • , Contact may irritate or burn eyes. , • '- Skin Irritating to skin 4 - Inhalation - Avoid breathing dust/furne/qas/mlstivapors/spray , . •• • 'Ingestion Do not ingest. . - - t _ •• I . Target organs ' Eyes. Skin. Respiratory system, lungs. Chronic effects Conjunctiva Signs and symptoms Corneal damage Conjunctivitis Irritation of eyes and mucous membranes Potential environmental effects Keep out of waterways 3 Composition / Information on Ingredients .' . Hazardous components Cass # Percent -. , TALC (POWDER) 14807-96-6 - ' 20-35 AMORPHOUS SILICA (RESPIRABLE DUST) 112926008 1 —3 TITANIUM DIOXIDE 13463-67-7 ,, 1-3 . . Non-hazardous components - Cass #. Percent- ,I REACTION . PRODUCT: B1SPHENOL.A-(EPICHLORHYDRIN) EPDXY RESIN 25068-38-6 • -, 40-50 (NUMBER AVERAGE MOLECULARWEITHE <= 700) . .. , ., Other components below reportable levels . - 20 -35 . • "'1' Additional components - . - -S Cáss # . • ,..Percent . -, •. ' 4., ,. First Aid Measures . .. - • . First aid procedures Eye contact Immediately flush eyes with plenty of water for at least 15 minutes Remove ' contact lenses, if present and easy to do. Continue rinsing. Get medical' . attention immediately. . . - . - Skin contact Remove and isolate contaminated clothing and shoes. Wash off immediately . with plenty of water. Get medical attention if irritation develops and persists Inhalation If breathing is difficult, remove to fresh air and keep at rest in a position - - . comfortable for breathing. Call a physician if symptoms develop or persist. -Ingestion Rinse mouth thoroughly. Do not induce vomiting without advice from poison • ' • • , . ,. . • control center. If ingestion of a large amount-does occur, call a poison control • - , ' center immediately. • - .•. . , , . .. - Notes to physician Symptoms may be delayed 4, I - ' 4801 Crystal Hill Road • North Little Rock, AR 72118 • Phone: (888) 831-1650 • Fax: (501) 758-3814 • Web: qJadéxonhine.om _•5 • -I I • , .'• • t •'-- . . ',-••• ••••.,•• -'-_ 1, •- .-.•-*• , _•5 4 -.. -, .1 ' " 1' _•'' - • ',' 4 -, . - I North Little Rock, AR 72118 structure uuara LpOXy Phone: (501) 758-8628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET General advice Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. Fire Fighting Measures Flammable properties The product is not flammable. No unusual fire or explosion hazards noted. Extinguishing media S Suitable extingUishing Dry chemical, 602, or water spray. Alcohol foam. media Fire fighting (equipment/instructions) In the event of fire, cool tanks with water spray. Use water spray to cool unopened containers. Cool containers exposed to flames with water until well after the fire is out. Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Specific methods In the event of fire, cool tanks with water spray. Use water spray to cool unopened containers. Accidental Release Measures S Personal precautions . Keep unnecessary personnel away. Keep upwind. Environmental precautions Do not flush into surface water or sanitary sewer system. S Methods for containment Stop the flow of material, if this is without risk. Dike the spilled material, where this is possible. Prevent entry into waterways, sewer, basements or confined .5 areas. Methods for clthning up Large Spills: Dike far ahead of spill for later disposal. Use a non-combustible S material like vermiculite, sand or earth to soak up the product and place into a container for later disposal. Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination. Following product recovery, flush area with water. Never return spills in original containers for re-use. Handling and Storage .5 Handling ' Do not get this material in contact with eyes. Avoid contact with skin. Do not empty into drains. Storage Use care in handling/storage. Keep container tightly closed. Store in a closed ,• container away from incompatible materials. / 8 Exposure Controls I Personal Protection Occupational exposure limits US. ACGIH Threshold Limit Values . Components Type Value Form S TALC (POWDER) TWA 2 Mg/M3 Respirable fraction. - (14807-96-6) TITANIUM DIOXIDE TWA 10 Mg/M3 (13463-67-7) US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1000) Components Type Value Form TITANIUM DIOXIDE PLE 15 mg/M3 Total Dust. (13463-67-7) US. OSHA Table Z-3(29CFR 1910.1000) Components Type Value Form AMORPHOUS SILICA TWA 0.8 mg/M3 (RESPIRABLE DUST) . (112926-00-8) 5 20 rnppcf TALC (POWDER) TWA 0.3 Mg/M3 Total Dust. (14807-96-6) 20mppcf ., S • 2.4 mppcf Engineering controls I Good general ventilation (typically 10 air changes per hour) shOuld be used: Ventilation rates should be matched to conditions. If applicable, use process 4801 Crystal Hill Road • North Little Rock, AR 72118 a Phone: (888) 831-1650 • Fax: (501) 758-3814 • Web: quadexonline.com I - - QUADEX P1 J1 structure uuara epoxy North Little Rock, AR 72118 Phone: (501) 758-8628 Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Personal protective equipment Eye / face protection Skin protection Respiratory protection General hygiene considerations Do not get in eyes. Chemical goggles are recommended. Avoid contact with the skin. Wear protective gloves. Wear suitable protective clothing as protection against splashing or contamination. When workers are facing concentrations above the exposure limit they must use appropriate certified respirators. Do not get in eyes. Avoid contact with skin. Physical & Chemical Properties Appearance Not available. Physical state Liquid. Form Viscous Liquid Color Off-white. Odor Not available. Odor threshold Not available. pH Not available. Vapor pressure Not available. Vapor density Not available. Boiling point 3020 F (1500 C) Melting point/Freezing point Not available. Solubility (water) Not Soluble. Specific gravity 1.368 Relative density Not available. Flash point Not available. Flammability limits in air, Not available. upper, % by volume Flammability limits in air, Not available. lower, % by volume Auto-ignition temperature 5720 F (3000 C) Other data Density 11.4 lb/gal Chemical Stability & Reactivity Information Chemical stability Stable under normal temperature conditions. Conditions to avoid Contact with incompatible materials. Incompatible materials Strong oxidizing agents. Hazardous decomposition products Irritating and/or toxic fumes and gases may be emitted upon the products Ii decomposition. S I I • I UAILuIUyI(.d1 in, UIIIIdIIUII - - - Toxicological data Components Test Results -AMORPHOUS SILICA (RESPIRABLE DUST) (112926-00-8) Acute Oral LD50 Mouse: > 15000 mg/kg Acute Oral LD50 Rat: > 22500 mg/kg Local effects Irritating to skin. Contact may irritate or burn eyes. Chronic effects Hazardous by OSHA criteria. Prolonged inhalation may be harmful. Prolonged exposure may cause chronic effects. Carcinogenicity This product contains crystalline silica. Silica is a known carcinogen; however in this encapsulatec form the normal routes of exposure are unavailable. ACGIH Carcinogens TALC (POWDER) (CAS 14807-96-6) A4 Not classifiable as a human carcinogen. TITANIUM DIOXIDE (CAS 13463-67-7) A4 Not classifiable as a human carcinogen. IARC Monographs. Overall Evaluation of Carcinogenicity 4801 Crystal Hill Road • North Little Rock, AR 72118 • Phone: (888) 831-1650 • Fax: (501) 758-3814 • Web: quadexonline.com & North Little Rock, AR 72118 structure uuarci pOX Phone: (501)758-8628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET AMORPHOUS SILICA (RESPIRABLE DUST) 3 Not classifiable as to carcinogenicity to humans. (CA5112926-00-8) TALC (POWDER) (CAS 14807-96-6) 2B Possibly carcinogenic to humans. 3 Not classifiable as to carcinogenicity to humans. TITANIUM DIOXIDE (CAS 13463-67-7) 213 Possibly carcinogenic to humans c.. Ecological Information Toxicological data Components Test Results TITANIUM DIOXIDE (CAS 13463-67-7) EC50 Water flea (Daphnia magna): > 1000 mg/148 hours LC50 Mummichog (Fundulus heteroclitus): > 1000 mg/I 96 hours * Estimates for product may be based on additional component data not shown - Ecotoxicity Contains a substance which causes risk of hazardous effects to the environment. Environmental effects An environmental hazard cannot be excluded in the event of unprofessional handling or disposal Aquatic toxicity No data available for this product. - Persistence and Not available. degradability Disposal Considerations Disposal Instructions Do not allow this material to drain into sewers/water supplies. This product, in its Waste from residues I - unused products Transport Information DOT Not regulated as dangerous goods. present state, when discarded or disposed of, is not a hazardous waste according to Federal regulations (40 CFR 261.4 (b)(4)). Under RCRA, it is the responsibility of the user of the product to determine, at the time of disposal, whether the product meets RCRA criteria for hazardous waste. Dispose in accordance with all applicable regulations. Not applicable. Regulatory Information US federal regulations This product is a "Hazardous Chemical" as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200. CERCLNSARA Hazardous Substances - Not applicable. Drug Enforcement Administration (DEA). List 2, Essential Chemicals (21 CFR 1310.02(b) and 131 0.04(f)(2) Not regulated DEA Essential Chemical Code Number - Not regulated Drug Enforcement Administration (DEA). List 1 & 2 Exempt Chemical Mixtures (21 CFR 1310.12(c)) Not regulated S DEA Exempt Chemical Mixtures Code Number Not regulated CERCLA (Superfund) reportable quantity None Superfund Amendments and Reauthorization Act of 1986 (SARA) Hazard categories Immediate Hazard - No S Delayed Hazard - No Fire Hazard - No Pressure Hazard - No Reactivity Hazard - No Section 302 extremely No hazardous substance Section 311 hazardous No chemical ' Inventory status Country(s) or region Inventory name On inventory (yes/no) 4801 Crystal Hill Road • North Little Rock, AR 72118 w Phone: (888)831-1650 • Fax: (501)758-3814. Web: quadexonline.corn N • S. . ' North Little Rock, AR 72118 structure ivara I:pOXy Phone: (501)758-8628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET Australia Australian Inventory of Chemical Substances (AIS) Yes Canada Domestic Substances List (DSI) Yes Canada Non-Domestic Substances List (NDSI) - No China Inventory of Existing Chemical Substances in China (IECSC) No Europe European Inventory of Existing Commercial Chemical Substances Yes , (EINECS) Europe European List of Notified Chemical Substances (ELINCS) No Japan Inventory of Existing and New Chemical Substances (ENCS) No Korea Existing Chemicals List (ECI) No New Zealand New Zealand Inventory No Philippines Philippine Inventory of Chemicals and Chemical Substances No (PICCS) United States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory Yes A'Yes' indicates that all components of this product comply with the inventory requirements administered by the governing country(s) State regulations This product does not contain a chemical known to the State of California to cause cancer, birth defects or other reproductive harm. US - New Jersey RTK - Substances: Listed substance . AMORPHOUS SILICA (RESPIRABLE DUST) (CAS 112926-00-8) Listed. TALC (POWDER) (CAS 14807-96-6) Listed. TITANIUM DIOXIDE (CAS 13463-67-7) Listed. US -Pennsylvania RTK - Hazardous Substances: Listed substance TALC (POWDER) (CAS 14807-96-6) Listed. TITANIUM DIOXIDE (CAS 13463-67-7) Listed. i 16. Other Information . Further information HMIS® is a registered trade and service mark of the NPCA. • HMIS® ratings Health; 2 - Flammability: 1 Physical hazard: 1 NFPA ratings Health: 2 Flammability: 1 . Instability: 0 Disclaimer The information provided in this Safety Data Sheet is correct to the best of our •. knowledge information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification, The information relates only to the'specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Issue date Not available. This data sheet contains Product and Company Identification: Synonyms changes from the previous Physical & Chemical Properties: Multiple Properties version in section(s): Transport Information: Material Transportation Information Regulatory Information: United States 'S 4801 Crystal Hill Road • North Little Rock, AR 72118 • Phone: (888) 831-1650 • Fax: (501) 758-3814. Web: quadexonlinelcom .5 North Little Rock, AR 72118 structure (ivarcl IpOXy. Phone: (501)7588628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET PRODUCI QUADEX EPDXY ' , ' ;iSStiE DATE 16July 2013 ? PRODUCT IDENTIFICATION Material name SG-2500 Series Part B Version# , 01 . Revision date 02-07-2012 CAS# Mixture . Product use Protective Coatings Synonym(s) SG-2508 . Manufacturer Quadex Address P0 Box 1639 Jackson, MS 39215-1639 Contact Name Mary Ellen Snow E-Mail mary.snow@ergon.com . Hours of Operation 8:00AM - 5:00PM ' QuadexGenéral Assistance 888-831-1650 , 24 Hour Emergency CHEMTREC North America 1 (800) 424 9300 International 1 (703) 527 3887 HAZARDS IDENTIFICATION Emergency overview Harmful in contact with eyes Possible cancer hazard may cause cancer based on animal data. Prolonged exposure may cause chronic effects. OSHA regulatory status This product is considered hazardous under 29 CFR 1910.1200 (Hazard - Communication). Potential health effects . - ,- Routes of exposure Inhalation. Eye contact Eyes .. Eye contact may result in corneal injury. Contact may irritate or burn - " eyes. Do not get this material in contact with eyes. Skin J Avoid contact with skin. Inhalation Prolonged inhalation may be harmful. Avoid breathing * . dust/fume/gas/mist/vapors/spray. . . Ingestion Do not ingest Target organs Cardiac. Eyes. RESPIRATORY SYSTEM. , Chronic effects Conjunctiva. Signs and symptoms Corneal damage. Conjunctivitis. * Potential environmental effects May cause long-term adverse effects in the environment: 3 COMPOSITION / INFORMATION ON INGREDIENTS Components Cass # . Percent , 4,4'-lSOPROPYLlDENEDlPHNOL 80-05-7 10-20 AMORPHOUS SILICA (RESPIRABLE DUST) 112926-008 ' ,9-10 BENZYL ALCOHOL 100-51-6 - . .. 9-10 .'.... - . TALC (MG3H2(S103)4) / . 14807-96-6 1 -3 Other components below reportable levels , • -. 60 -65 .. 4. FIRST AID MEASURES . . . • . First aid procedures .' Eye contact Immediately flush eyes with plenty of water for at least 15 minutes. Remove contact lenses, if present and easy to do. Continue rinsing. Get medical attention immediately. Skin contact Take off immediately all contaminated clothing. Rinse skin with water/shower. Inhalation If breathing is difficult, remove to fresh air and keep at rest in a position comfortable for breathing. Call a physician if symptoms develop or persist. - I . Ingestion Rinse mouth. If ingestion of a large amount does occur, call a poison control center . immediately. Notes to physician General advice Symptoms may be delayed Ensure that medical personnel are aware of the material(s) involved, and take . . - - . precautions to protect themselves. -. - . - . - - • . . c . . - - . . . -, •,1 4801 Crystal Hill Road .North Little Rock, AR 72118 • Phone: (888)831-1650. Fax: (501) 758-3814 • Web: quadéxonhine.corn North Little Rock, AR 72118 structure (ivarcl ipoxy ' Phone: (501)758-8628 ( / QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET 5. Fire Fighting Measures Extinguishing media Suitable extinguishing Water fog. Foam. Carbon dioxide (CO2). Powder. media Unsuitable extinguishing Do not use water jet as an extinguisher, as this Will spread the fire. media Protection of firefighters In the event of fire and/or explosion do not breathe fumes. Self-contained Protective equipment breathing apparatus and full protective clothing must be worn in case of fire. and precautions for Use standard firefighting procedures and consider the hazards of other firefighters involved materials. Move container from fire area if it can be done without risk. - Fire fighting In case of fire and/or explosion do not breathe fumes. ALWAYS stay away equipment/instructions from tanks engulfed in flame. Withdraw immediately in case of rising sound from venting safety device or any discoloration of tanks due to fire. Move containers from fire area if you can do so without risk. For massive fire in cargo area, use unmanned hose holder or monitor nozzles, if possible. If not, withdraw and let fire burn out. Specific methods Firefighters must use standard protective equipment including flame retardant coat, helmet with face shield, gloves, rubber boots, and in enclosed spaces, SCBA. Structural fire fighters protective clothing will only provide limited protection. Accidental Release Measures Personal precautions Keep unnecessary personnel away. Do not touch damaged containers or spilled material unless wearing appropriate protective clothing. Keep people away from and upwind of spill/leak Keep upwind Keep out of low areas Ventilate closed spaces before entering them. Enviionmental Prevent further leakage or spillage if safe to do so. Do not contaminate precautions water. Methods for containment ELIMINATE all ignition sources (no smoking, flares, sparks or flames in immediate area). Stop the flow of material, if this is without risk. Dike the spilled material-, where this is possible. Use water spray to reduce vapors or divert vapor cloud drift. This material is classified as a water pollutant under the Clean Water Act and should be prevented from contaminating soil or from entering sewage and drainage systems which lead to waterways. Methods for cleaning up Extinguish all flames in the vicinity. Should not be released into the environment. Large Spills: Stop the flow of material, if this is without risk. Dike the spilled material; Where this is possible. Cover with plastic sheet to prevent spreading. Use a nor- combustible material like vermiculite, sand or earth to soak up the product and place into a container for later disposal. Following product recovery, flush area with water. Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination. Never return spills in original containers for re-use. For waste disposal, see section 13 of the SDS. Handling and Storage Handling Do not smoke. Do not get this material in contact with eyes. Avoid prolonged exposure. Avoid release to the environment. Storage The pressure in sealed containers can increase under the influence of heat. Store in well-ventilated place. Keep container tightly closed. Keep out of the reach of children. Use care in handling/storage. 4801 Crystal Hill Road • North Little Rock, AR 72118. Phone: (888) 831-1650 • Fax: (501) 78-3814 • Web: quadexonline.com North Little Rock, AR 72118 structure uuarci L:pOXy Phone: (501) 75878628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET 8. Exposure Controls I Personal Protection Occupational exposure limits US. ACGIH Threshold Limit Values Components Type Value Form TALC (MG3H2(S103)4) TWA 2 Mg/M3 Respirable fraction. (14807-96-6) US. OSHA Table Z-1 Limits for Air Contaminants (29 CFR 1910.1 000) Components Type Value ' Form AMORPHOUS SILICA TWA 0.8mg/rn3 (RESPIRABLE DUST) (112926-00-8) 20 mppcf TITANIUM DIOXIDE (MG3H2(S103)4) TWA 0:3 Mg/M3 Total Dust. (14807-96-6) 0.3 Mg/M3 Respirable 20 mppcf 2.4 mppcf Respirable Engineering controls Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. . Personal protective equipment Eye I face protection Do not get in eyes. Chemical goggles are recommended. Eye wash fountain is recommended. Skin protection Wear protective gloves. Respiratory protection When workers are facing concentrations above the exposure limit they must use - appropriate certified respirators. General hygiene When using do not smoke. Do not get in eyes. Keep away from food and drink. Handle considerations in accordance with-good industrial hygiene and safety practice. 9 Physical & Chemical Properties Appearance Viscous liquid . Physical state Liquid. Form Liquid. Color Light green. Odor Amine-like. Odor threshold Not available. pH Alkaline Vapor pressure Not available. Vapor density Not available. • Boiling point Not available. Melting point/Freezing point Not available. Solubility (water) Not available. Specific gravity 1.116 Relative density Not available. Flash point > 200°F(> 93.30C) Flammability limits in air, Not available. upper, % by volume Flammability limits in air, Not available. lower, % by volume Auto-ignition temperature • Not available. • - Other data - Density 9.31b/gal -I • - Flammability class Combustible IlIB Flash point class Combustible lilB 7 . 4801 Crystal Hill Road • North Little Rock, AR 72118 • Phone: (888) 831-1650 • Fax: (501) 758-3814 .Web: quadexonline.corn I,-, - North Little Rock, AR 72118 structure (ivarcl tpoxy Phone: (501) 758-8628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET Chemical Stability & Reactivity Information Chemical stability Material is stable under normal conditions. Conditions to avoid Avoid exposure to high temperatures or direct sunlight. Incompatible materials Strong oxidizing agents. Strong adds. Alcohols. Hazardous decomposition Ammonia. Phenolic fumes may be released upon decomposition. products Possibility of hazardous Hazardous polymerization does not occur. reactions Toxicological Information Toxicological data Product Test Results SG-2S00 Series Part B Acute Dermal LD50 Rabbit: 23364.4863 mg/kg estimated Acute Inhalation LCI 00 Rat: 2336.4485 mg/I estimated Acute Inhalation LC50 Rat: 11682.2432 mg/I estimated Acute Oral LD50 Mouse: 7773.6392 mg/kg estimated Acute Oral LD50 Rabbit: 22663.5508 mg/kg estimated Acute Oral L050 Rat: 7970.3906 mg/kg estimated Acute Other LD50 Guinea pig: 4672.897 mg/kg estimated Acute Other LD50 Mouse: 3785. 0466 mg/kg estimated Acute Other LD50 Rabbit: 875.6567 mg/kg estimated Acute Other LD50 Rat: 619.1589 mg/kg estimated Components Test Results BENZYL ALCOHOL (100-51-6) Acute Dermal LD50 Rabbit: 2000 mg/kg Acute Inhalation LC100 Rat: 200-300 mg/I 8 Hours Acute Inhalation LC50 Rat: 1000 mg/I 8 Hours Acute Oral LD50 Mouse: 1580 mg/kg Acute Oral LD50 Rabbit: 1940 mg/kg Acute Oral LD50 Rat: 1230- 3100 mg/kg Acute Other LD50 Guinea pig: >400 mg/kg Acute Other LD50 Mouse: 324 mg/kg Acute Other LD50 Rat: 53 mg/kg AMORPHOUS SILICA Acute Oral LD50 Mouse: > 15000 mg/kg (RESPIRABLE DUST) (112926-00-8) Acute Oral LD50 Rat:> 22500 mg/kg 4,4'- ISOPROPYLIDENEDI PHENOL Acute Oral LD50 Mouse: 2500 mg/kg (80-05-7) Acute Oral LD50 Rat: 3300 mg/kg Acute Other LD50 Rabbit: 150 mg/kg Local effects Contact may irritate or burn eyes. Chronic effects Hazardous by OSHA criteria. Prolonged inhalation may be harmful. Prolonged exposure may cause chronic effects. Carcinogenicity Possible cancer hazard - may cause cancer based on animal data. This product contains crystalline silica. Silica is a known carcinogen; however in this encapsulated form the normal routes of exposure are unavailable. ACGIH Carcinogens TALC (MG3H2(S103)4) (CAS 14807-96-6) A4 Not classifiable as 'a human carcinogen. IARC Monographs. Overall Evaluation of Carcinogenicity P AMORPHOUS SILICA (RESPIRABLE DUST) 3 Not classifiable as to carcinogenicity to humans. (CAS1 12926-00-8) TALC (MG3H2(S103)4) (CAS 14807-96-6) 2B Possibly carcinogenic to humans. 3 Not classifiable as to carcinogenicity to humans. 4801 Crystal Hill Road • North Little Rock, AR 72118 • Phone: (888) 831-1650 • Fax: (501) 758-3814 • Web: quade'xonhine.com - North Little Rock, AR 72118 structure uuara epoxy Phone: (501)758-8628 QUADEX Fax: (501) 758-3814 MATERIAL SAFETY DATA SHEET 12. Ecological Information Ecotoxicological data rrouuci vest riesuiis SG-2500 Series Part B LC50 Fish: 0.9333 mg/I 96 hours estimated ComponentsTest Results BENZYL ALCOHOL (100-51-6) LC50 Bluegill (Lepomis macrochirus): 10 mg/I 96 hours 4,4- ISOPROPYLI DENEDI PHENOL (80-05-7) EC50 Water flea (Daphnia magna): 9.2 - 11.4 mg/I 48 hours LC50 Fathead minnow (Pimephales promelas): 3.6 - 5.4 mg/I 96 hours Estimates for product may be based on additional component data not shown. - Ecotoxicity Contains a substance which causes risk of hazardous effects to the environment Environmental effects An environmental hazard cannot be excluded in the event of unprofessional handling or disposal Persistence and degradability Not available. Disposal Considerations Waste codes Not assigned. Disposal Instructions Review federal, state/provincial, and local government requirements prior to disposal. Do not allow this material to drain into sewers/water supplies. Dispose in accordance with all applicable regulations. Contaminated packaging Empty containers should be taken to an approved waste handling site for .' recycling or disposal. Transport Information DOT Basic shipping requirements: UN number UN1760 Proper shipping name Corrosive Liquid, n.o.s. (4,4'-ISOPROPYLIDENEDIPHENOL) Hazard class 8 Packing group II Additional information: Special provisions B2, IB2, Ti 1, TP2, TP27 Packaging exceptions 154 Packaging non bulk 202 Packaging bulk 242 ERG number 154 DOT Regulatory Information US federal regulations This product is a 'Hazardous Chemical" as defined by the OSHA Hazard Communication Standard 29 CFR 1910.1200. All components are on the U.s. EPA TSCA Inventory List. CERCLA/SARA Hazardous Substances - Not applicable. Drug Enforcement Administration (DEA). List 2, Essential Chemicals (21 CFR 1310.02(b) and 1310,04(f)(2) Not regulated DEA Essential Chemical Code Number Not regulated Drug Enforcement Administration (DEA). List 1 & 2 Exempt Chemical Mixtures (21 CFR 1310.12(c)) 4801 Crystal Hill Road NNorth Little Rock, AR 72118 • Phone: (888) 831-1650 • Fax: (501) 758-3814 • Web: quadexonhinecom V • -. PIE North Little Rock, AR 72118 structure uuarci IpOXy Phone: (501)758-8628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET Not regulated DEA Exempt Chemical Mixtures Code Number Not regulated US EPCRA (SARA Title Ill) Section 313 - Toxic Chemical: De minimis concentration 4,4'-lSOPROPYLlDENEDlPHENOL (GAS 80-05-7) 1.0% US EPCRA (SARA Title Ill) Section 313 - Toxic Chemical: Listed substance 4,4'-lSOPROPYLlDENEDlPHENOL (GAS 80-05-7) Listed. CERCLA (Superfund) reportable quantity None Superfund Amendments and Reauthorization Act of 1986 (SARA) Hazard categories Immediate Hazard - Yes Delayed Hazard - Yes Fire Hazard - No Pressure Hazard - No Reactivity Hazard - No Section 302 No Vi Hazardous substance Section 311 hazardous No - - chemical V Inventory status Country(s) or region Inventory name On inventory (yes/no)* V Australia Australian Inventory of Chemical Substances (AlS) Yes V Canada Domestic Substances List (OSI) Yes V Canada Non-Domestic Substances List (NDSl) No V China Inventory of Existing Chemical Substances in China (IECSC) No V Europe European Inventory of Existing Commercial Chemical Substances V Yes (EINECS) - Europe European List of Notified Chemical Substances (ELINCS) V No V V Japan Inventory of Existing and New Chemical Substances (ENCS) No Korea Existing Chemicals List (ECI) No V V New Zealand New Zealand Inventory V No Philippines Philippine Inventory of Chemicals and Chemical Substances No V (PICCS) United States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory Yes A Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s) V State regulations This product does not contain a chemical known to the State of California to V cause cancer, birth defects or other reproductive harm. US - New Jersey RTK - Substances: Listed substance V 4,4'-ISOPROPYLlDENEDlPHENOL (GAS 80-05-7) 1 Listed. V AMORPHOUS SILICA (RESPIRABLE DUST) (CAS1 12926-00-8) Listed. V TALC (MG3H2(S103)4) (GAS 14807-96-6) - Listed. . .• US - Pennsylvania RTK - Hazardous Substances: Listed substance V V 4,4'-ISOPROPYLI DENEDI PHENOL (GAS 80-05-7) Listed. BENZYL ALCOHOL (GAS 100-51-6) Listed. TALC (MG3H2(S103)4) (GAS 14807-96-6) Listed. 16. Other Information - V Further information HMIS® is a registered trade and service mark of the NPCAV V HMIS® ratings Health: 2 Flammability: 1 . Physical hazard: 0 NFPA ratings Health: 2 Flammability: 1 Instability: 0 4801 Crystal Hill Road • North Little Rock AR 72118 • Phone (888) 831-1650 • Fax (501) 758-3814 m Web quadexonline corn North Little Rock, AR 72118 structure uuara tpoxy Phone: (501)758-8628 QUADEX Fax: (501)758-3814 MATERIAL SAFETY DATA SHEET Disclaimer The information provided in this Safety Data Sheet is correct to the best of our knowledge information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification, The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. Issue date Not available. This data sheet contains Product and Company Identification: Synonyms changes from the previous Physical & Chemical Properties: Multiple Properties version in section(s): Transport Information: Material Transportation Information Regulatory Information: United States 1 J J 4801 Crystal Hill Road • North Little Rock, AR 72118. Phone: (888) 831-1650 • Fax: (501) 758-3814 i Web: quadexonline.com SEWER RESTORATION PRDUCTS V ,. A * SEWER RESTORATION PRODUCTS elf 1 4/ t, 4* -::\ : 411 , • *40 lie) 11-F-1111111 11JONU *.I$ - VJToi /1 S t . GM e,-,s ling ( .1) J • V • •1 / :. I Prepared By: James Dügger 390 Carrier Boulevard Richland, MS 39218 P601.932.8365 F6019328466 paragon - . technical services, inc. LABORATORY TEST REPORT ., 813/2010 Oblective The physical properties of the Quadex epoxy concrete. coating (Formulation 402-23)! were quantified in the uncured and cured states in accordance with ASTM methods. 1• Results Uncured Properties: . Part A Resin • Part B Hardener 1.37 . Specific Gravity, 25°C - 1.12 • • eld Viscosity, 25°C 60,000 cPs I • 200,000 cPs Brookfi Handling & Cured Properties: Gel Time, 150 grams © 23°C ASTM D2471 18 minutes Tensile Strength ASTM 0638 5,600 psi % Elongation ASTM D638 . . 4.8 Flexural Strength ASTM D790 1.1,000 psi Compressive Strength ASTM D695 15,000 psi Shore D Hardness ASTM D2240 .83 Taber Abrasion, CS17 Wheel ASTM 04060 <100mg loss (1 kg load/1000 cycles) Adhesion to Concrete ASTM 04541 >2000 psi (substrate failure) Water Vapor Transmission ASTM 01651 3.0 gms / m2 (24 hrs) Water Absorption ASTM D570 0.15% Volatile Organic Content . ASTM 02580 . 10 grams / liter 390 Carrier Bouleva rd c Richland, MS 3921 P 601.932.8365 F 601.932.8466 paragon technical services, inc. LABORATORY REPORT FOR Mr. Stewart Nance . QUADEX / INTERFITUSA L. 4801 Crystal Hill Road . North Little Rock, AR 72118 Physical Properties Gel Time, 150 grams at 25°C ASTMD2471 18 minutes Tensile Strength ASTM D638 5,600 psi % Elongation ASTM D638 4.8 Flexural Strength ASTM D790 11,000 psi Flexural Modulus ASTM D790 580,000 psi Compressive Strength ASTM D695 15,000 psi Shore D Hardness ASTM D2240 83 Taber Abrasion, CS 17 Wheel ASTM D4060 <100 mg loss (I kg load / 1000 cycles Adhesion to Concrete ASTM D4541 >2000 psi (substrate failure) Adhesion to Blasted Steel ASTM D4541 >3000 psi Water Vapor Transmission ASTM D1651 3.0 grams / m2 (24 hours) Water Absorption ASTM D570 0.15% Volatile Organic Content ASTM D2580 10 grams / liter Physical properties were evaluated on compounds cured for 5 days at 25°C / 50% relative humidity. 28-Day Chemical Resistance Chemical Solution % Average Weight Gain 20% Sulfuric Acid 0.88 5% Sodium Hydroxide 0.42 5% Ammonium Hydroxide 0.76 1% Nitric Acid 0.82 1% Ferric Chloride 0.35 1% Sodium Hypochlorite * 0.66 * 1 % sodium hypochlorite solution was prepared from fresh standard household bleach where the sodium hypochlorite solution concentration was assumed to be 5.25%. Chemical resistance was evaluated on compounds cured for 7 days at 25°C I 50% relative humidity. I Page 10f2 TECHNOLOGY Home Featured Editorial Trenchless International News Webinars Conferences Subscribe Resources Contact Us Search Trenchless Online Pipe Marking Wall Chart : duralabelcom -' Free wall chart - pipe color coding standards set by ANSI and ASME t [ on fII conferencerate HOPE PIPE:THE SUSTAINABLE SOLUTION PLASTICS _______ PIPE l,'srITu'rh JO(H}.SI FOR INFO, 'ttruk"tur"al NO MAX 1il1 LeaderThe World MALA L :ki Sherwood, Ark., Tackles Manhole I/I Issues Using Trenchless Methods <All stories in this section By Mike Kezdi — Mar 19, 2014 - Like most communities across the Urited States, the City of Sherwood, . •..' Ark., at 65-years-old, has its fair share of infiltration and inflow problems ..• due to an aging sewer system. ~Sherwood, located in central Arkansas in the shadow of the state capital — city of Little Rock, has a growing population of 29,523 and approximately 40 miles of sewers and about 4,500 manholes that are part of the -- Sherwood Wastewater Utility System. - _ According to Sherwood wastewater supervisor Charlie Cadie, the system 4 was established in the early 2000s after the City began taking over private ., - systems in its coverage area and in 2011, it began looking at aggressively tackling manhole rehabilitation as part of a larger sewer system upgrade. .. -. According to Lea Price, of Crist Engineers, Sherwood's engineer for the sewer project, the City discovered that the manholes were suffering from -'-' several problems. "Some of the manholes were the old brick type manholes with grout and bricks missing, which caused leaks. Some of the manholes were precast concrete and were leaking at the joints and some.of the manholes had bad pipe seals and were leaking around the pipe entry into the manhole," Price said. He continued, "Some of the manholes were leaking around the stairs and precast lift holes, and some of the manholes were deteriorated because of high levels of hydrogen sulfide." Cadie estimated that the City spends $25 to $30 to treat a gallon of fluid and because of these I/I problems, during rain events, the product being treated is about 99 percent rainwater. It's one of biggest things that we have that causes sewer treatment problems and flow problems," Cadie said. By reducing the Ill through the manhole rehabilitation program, the City will save money on treatment equipment, a -, - cost-savings that is passed on to the system's users. - Researching Its Options Once Sherwood decided to address its infiltration and corrosion problems, officials set out to research different rehabilitation products and methods that had been used ortrialed in nearby Little Rock. .• - Sherwood was looking for systems with a 100-year life expectancy. To L '"' . Miller fli PipelineCorp. qualify products, Sherwood tested many cementitious and polymer - products to rehabilitate its manholes. Since Sherwood's problems were diverse, officials expected and found that several different products would , .- - •• . '- prove optimal for different Circumstances, hence the need for a • manufacturer with a full and diverse product line. • r • ' Likewise, officials found that the contractor applying the products was 's ,• • 4 critically important so they decided to focus on compatible products from 4 • the same manufacturer and that must be applied by manufacturer trained ••• - . . - and certified applicators. The City did not have to look far beause local manufacturer Quadex had been supplying manhole rehab products nationally since 1991 and had a full line of cements and epoxies sold only to trained certified applicators and cities 11 , . I with proper cement and epoxy spray equipment. . - "We used a variety of Quadex products, depending on what the particular problem was at each manhole," Price said. Some of the manholes received a cementitious liner only'some of the manholes received a cementitious liner followed by an epoxy liner and some of the manholes received only an epoxy liner." Price further explained, "The cementitious followed by an epoxy liner method was used in manhole that were deteriorated.due to hydrogen sulfide and were typically located near pump stations and the wastewater treatment plant. We used the epoxy liner only method for some precast manholes in relatively new areas that had minor leaks and the manholes were in good shape otherwise." In all, Sherwood called upon four Quadex products: Quadex Quad-Plug, Quadex Hyperform, Quadex Aluminaliner and Quadex Structure Guard, to solve its Ill problems. The winning bidder for the manhole work went to Lewis Concrete Restoration, a Quadex certified applicator. Quadex's hybrid calcium aluminant cementitious product provided superior structural rebuild capabilities and moderate corrosion protection and proved to provide the best bang for the buck for structurally rebuilding . deteriorated manholes and effectively stopping infiltration and mild corrosion. No degree of deterioration could not be repaired with 2-to 4-in, of shotcreted calcium aluminant. For more severe corrosion situations, Quadex's Structure Guard epoxy coating proved to have superior bonds to damp underground concrete that is required for long-term bonding to newer precast manholes or concrete lift stations. The City turned to Structure Guard for topcoating structurally deteriorated manholes first lined with calcium aluminant cements made by Quadex. Phase I Finishing Up Cadie says the program is on pace for a 2017 completion, and the first phase is 90 percent complete, with the City already looking ahead to Phase II. The manhole project complements a citywide sewer system rehabilitation and upgrade project. . In the first phase, approximately 800 manholes, with a vertical footage of approximately 3,991 ft, were identified for . . rehabilitation and Cadie is pleased with the results. Given the heavy rains last year and snow and ice this year, he has not noticed any signs of deterioration or'significant I/I even in areas that are prone to flooding. "They (Quadex) do some really good work and have a real good product," Cadie said. "1 am really happy with these guys, they really do real good work." Mike Kezdi is an assistant editor for Trenchiess Technology. ." . <All stories in this section / 0 I Hotel Indigo Waco - Baylor Hotelindigo.com , $110.99 I Rest Price c,ivarentp.p , ) -. ..• Trenchless Technology Conferences Resources , Contact Us Featured Stories No-Dig Show ' Buyer"s Guide General Inquires Trenchless News Trenchless Technology Road Shows Forums Advertising Directional Drilling UIM Conference Classified Ads ' ' ..-" Editorial Pipe Cleaning Resource Center Benjamin Media, Inc Archives! Past Issues , , Webinars • - . -. I SPLN0. WW-511 SHEET 1 or 1 ",v t". CITY OF AUSTIN STANDARD PRODUCTS LIST for ORGANIC LINING FOR WASTEWATER MANHOLES USING DEPARTMENT: Water Utility ISSUED: 05/10/84. REVIEWED: 10/01/13 REVISED: 10/01/13 PREPARED BY: Bill Flynn, P.E./David Rinn CITY STOCK NUMBER: DESCRIPTION: Lining, Corrosion Resistant, spray or brush applied. Material shall be urethane, polyurethane or epoxy. Permitted uses as noted in Product Identification/Comment below. Substrate and surface preparation, application conditions, application equipment, material preparation, and curing shall be in strict accordance with manufacturer's written recommendations (product technical data sheet) unless written documentation from manufacturer requesting variance has been approved by the Austin Water Utility. LISTING MANUFACTURER PRODUCT IDENTIFICATION/COMMENT APPROVAL DATE 01/02/97 RAVEN CHEMICALS 400 Series High Build Epoxy Liner, 80 mils minimum R. Lamb 1024 North Lansing thickness Tulsa, OK 74106 Permitted Uses: See notes 3, 4, 5, 6, and 7 Applicators: Lewis Concrete Restoration, Eric Lewis National Power Rodding Ace Pipe Cleaning, Inc. - Approval Expires August 1, 2015 01/02/97 SPRAYROQ. INC. Spraywall Process, 80 Mils minimum thickness R. Lamb 4707 Alton Court Permitted Uses: See notes 3, 4, 5, 6, and 7 P.O. Box 101717 Applicator: Fuquay, Inc., John Fuquay Birmingham, AL 35210 Approval Expires August 1, 2015 07/01/97 SEALING SYSTEMS, INC. Flex-Seal with Primer, 80 mils minimum thickness R. Lamb 23230 West Thomess Blvd. Permitted Uses: Only in chimney area over grade rings Loretto, MN 55357 Approved Applicator not required Approval Expires August 1, 2015 10/01/13 QUADEX Structure Guard, 80 mils minimum thickness R. Lamb 13105 East 61" Street Permitted Uses: See notes 3, 4, 5, 6, and 7 Broken Arrow, OK 74012 Applicator: Lewis Concrete Restoration, Eric Lewis Approval Expires August 1, 2015 NOTE: Lining product used for repair shall be the same as that used in original application. Use of a different product, even if it is compatible with the original lining, requires written approval of the Austin Water Utility. The Contractor is responsible for coating application as required for the interior surface of sectional concrete manholes. If shop-coated sections are used, contractor shall apply touch-up as required and shall completely coat the interior of all grade-adjustment rings and invert areas using the same product as applied in the shop. Product may be applied to new manholes before wastewater lines are put into use or before hydrostatic testing of wastewater line or manhole, when allowed. Product may be applied to new manholes after wastewater lines have been put into use or after hydrostatic testing of wastewater line or manhole, when allowed. Product may be applied to existing manholes for rehabilitation. Minimum thickness will increase depending on manhole condition. Product may be applied to new lift station wet well before operation. Product may not to be used, regardless of any other permitted uses, if any part of the manhole or lift station wet well extends below existing groundwater level unless a water-proofing system, as specified on the drawings, is applied at the same time to the exterior surface of the manhole or wet well. Annise D. Parker Mayor Daniel W. Krueger, P.E., Director P.O. Box 1562 Houston, Texas 77251-1562 T. 832 395-2500 F. 832-395-2344 www.houstontx.gov January 31, 2014 Mr. James Dugger Quadex, Inc. 4801 Crystal Hill Road North Little Rock, AR 72118 RE: Application for Product Review of: Quadex, Inc. Quadex Structure Guard Application No. 204 Dear Mr. Dugger: The Product Approval Committee - Wastewater Subcommittee has reviewed the above referenced product application and found the product to be in full compliance with the City of Houston Standard Specification 09901— Protective Coatings (with Supplement 09901S issued on January 15, 2014). Approved products may be reviewed periodically and evaluated for performance and quality. Failure or unsatisfactory performance may warrant the removal of the item from the approved products list. It is the manufacturer's responsibility to inform the Product Approval Committee of changes in the product Should you have any questions, please contact Barry Morgenstern at (832) 395-2301 Ravi Kaleyatodi P.E., CPM S Timothy Lincoln, P.E. Senior Assistant I ctor City Engineer Engineering Branch S Engineering and Construction Division RK~TH:BM C: Rajiv Arya (PDF) Subcommittee Chairs (PDF) 0 Subcommittee Members (PDF) Council Members: Brenda Stardig Jerry Davis Ellen R. Cohen Dwight A. Boykins Dave Martin Richard Nguyen Oliver Pennington Edward Gonzalez Robert Gallegos Mike Laster Larry V. Green Stephen C. Costello David W. Robinson Michael Kubosh C.O. 'Brad6 Bradford Jack Christie Controller Ronald C. Green CITY OF HOUSTON Department of Public Works & Engineering