Loading...
HomeMy WebLinkAbout1 LEGOLAND DR; ; CB971460; Permitf \. \ 10/30/97.13:03 Page 1 of 1 . 1 . ' Job Adq.ress:, 1 LEGO PR ' ·. B U J: L D I N G p ERM I '1' Sutte: .· Perm:t:t No!_ ·Cl:{9•7'14.6 0 Project No: A~6oi43~ Develbpment ·No·:· F:13050·O1 . ·- ~ ' ~ • ~, , r Permit type: CO~MERCIAL BUILDING Parcel Nor 211-022-16-00 Lot#: . · ·c:onstruction :Ty:pe i _\il\l _ ' =· '' ,, -Valuation: o Occupancy Group: · Reference#: Desi:::ript:i,on: µE<1QLAND OUTER PARK -~ PARKING LOT AND· LIGHTING CITY OF CARLSBAD J10 . . . ·status} .. ISSUEtr . . . Applied: ,.06';0.3/$7 . Apr/Issue: 10;30;.9·7 . Ente:i:-ed By: l"!DP . 453.:...oioo · - 2075 Las Pl;llmas Pr., Carlsbad, CA 9.2009 (619) 438~116J: BUILDING P E R M. I T PCR No: PCR97098 ~rojsct No_: A.9603436 Development No:,. F;l.305001 06/04/98 15:19 Page. 1 of 1 Job Address : . ·1 LEGO DR Permit Type: PI.AN CHECK ~EVISION Parcel No: 211----022-16-00 Valuation: O . Occupancy Group: Suite: 7728 06/04/98 -OOOi 01 · -02 ·. C-PRMT -327 .oo -· Lot#: Reference#: De9c+ipti,on: SEE ATTACHEP . :· 11/10(97 TRAN$MITTAL DATED PERMIT C.B97-:-1460. Construction Type-: VN Status: I·SSUED Applied: 12/03/97 Apr/Is.sue: 06/04/98 -. Entered By:: MDP 310 453-;,-0100 'INSP._--:-___ DATE-___ ~ ....... CLEARANCE~_...._ ______ _ ' . CITY OF ~ARLSBA[) 2075 Las Palmas Dr., Carlsbad, _CA 92009 '(619) 4~8'..1161 r J PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 2075 Las Palmas Dr., Carlsbad CA 92009 (760) 438-1161 -1; ,,. PROJECT INFORMATION FOR OFFICE USE ONLY PLAN CHECK NO. CZ 7 ~ t (_[ ~ D EST. VAL. __________ _ Plan Ck. Deposit ________ _ Validated By __________ _ Date _____________ _ Address (include Bldg/Suite #) Business Name (at this address) Legal Description Lot No. Subdivision Name/Number Unit No. Phase No. Total # of units Assessor's Parcel # Existing Use Proposed Use #of~oms # of Bathrooms Name ·4£11i:1J!ifijtlPERtv10WNER ·· .. Name ·s .. a,'WORKERS~ COMPEN$'At10N· Address Address City ·'O'ov.1/le?"H:;o Agerrt,'.tofOWher City City Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: p- /4 -~/ State/Zip Telephone# State/Zip Telephone# 0 I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. fiil I have and will maintain workers' compensation, as required by Section 3700 of the· Labor Code, for the performance of the work for which this permit is ~ed. My worker's.c p~nsation ·nsurance c r er and licy number are: . 1 : rJ\ I /i'\h ~:\ . . U2~ /J Insurance Company , Polley No. ~lJ ~U7vU Expiration Date_~-+--,_:.}(/2_,,...{1~7~~~- (THIS SECTION NEED NOT BE COMPLETED IF TH PERMIT IS FOR ONE HUNDRED DOLLARS ($1001 OR LESS) 0 CERTIFICATE OF EXEMPTION: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars($ 0 , 00), in addition to !,cost of compensation, damages as provided for In Section 3706 of the La or cod • Interest and attorney's fees. SIGNATURE_..==Y-tc.....i.c:._--1..---::,.£.---------------------DATE +-'"'+ ....... ~f-H'-----7; .·· .: ···.::.·······AC#)c/i -;;-;a:•·0b'fi'I-•r:u 0 I, as owner of the pro erty or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section ______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES ONO 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number/ contractors license number): _____________________________________________ _ 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work): _______________________________________________________ _ PROPERTY OWNER SIGNATURE______________________ DATE ________ _ iboMi!I.EtE·;nii$ZSECTION'J!ofl'N.ONfflloEN.'YtiWilOitDINBiPERMtfsroHLW'.JWJl4);:;"'\?i :::r<r••:~_\•t;lll;l,fflt~r'~)t1.~fM:i!i7i:iiim;?.Jxrmel'rfi,~J:@!r'.''~· ''s:iil'''. ·'<,:w01vv, :;: :1,' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES O NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES O NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES O NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. :s.i -rcoNstijuctiQtfcw~1Ntf:KciEMi:;'1il'i,Zff1>: f1;rw ''":J,}'.Jif:;'t:.1:"":~~i"i!1,w1r,·.r,_,,,\\\:9::!':'::'t"~ "· ··· · · , ., ... t'Jt} ·v\ I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec. 3097(i) Civil Code). LENDER'S NAME______________ LENDER'S ADDRESS ;9;'1:·!··APPLICANT:,'CERT!FICATtONll"'i1'':••.·fit•¥e:.,.\.' ·'!''.','f:t:::::::;.·-::_·!'.:''7 ''.'.':r'."'~''-!--;•-:.:;,,;:;m,,,;;,n,:.;;;1[f1<P;1.::;'J;:•:.' I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citt of Carlsbad to enter upor, -~'.;e above mentioned property for inspection purposes. I ALSO AGREE TO ·sAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CIH IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height.· EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not c in 365 days from the date of such permit or if the building or work authorized by such permit is suspended :p::~~::;.:a;l::A:~:;fterthew of180days(Se nl .4.4UniformB "din:A~:de). fr Qrlo/7 lv)av.t:r t ·' 11 ,, . ,< Inspection List Permit#: CB971460 Type: COM l,.EGOLAND OUTER PARK PARKING LOT AND LIGHTING Date Inspection Item lnspect9r_ Act Comments 2/5/99 19 Final Structural RI 2/5/99 29 Final Plumbing RI 2/5/99 39 Final Electrical RI 2/5/99 49 Final Mechanical RI 2/5/99 89 Final Combo PD PA TICKET BOOTHS 2/5/99 89 Final Combo RI 12/3/98 11 Ftg/Foundation/Piers PD AP LIGHTS 11/25/98 11. Ftg/Foundation/Piers PD AP BRIDGE FTGS 11/24/98 34 Rough Electric PD NR 11/20/98 34 Rough Electric -PD PA 11/20/98 39 Final Electrical PD NR 11/18/98 34 Rough Electric PD .AP PARKING LOT PANELS 11/18/98 39 Final Electrical PD WC 9/9/98 11 Ftg/f ound1:1tion/Piers PD AP TICKET BOOTHS 8/31/98 11 Ftg/Foundation/Piers PD AP FLAGPOLE FrGS 8/27/98 31 Underground/Conduit-Wirin DH AP KIOSK 8/27/98 34 Rough Electric DH WC 8/24/98 31 Underground/Conduit-Wirin DH AP 8/21/98 31 Underground/Conduit-Wirin DH AP PLAN E109' UNDGRD ENTRY L 8/6/98 11 Ftg/Foundation/Piers DH AP 7/1/98 11 Ftg/Foundation/Piers Pb AP ~IGHT POLE BASES 7/1/98 31 Underground/Cortduit-Wirin PD AP 6/26/98 11 Ftg/Foundation/Piers DH NR 6/22/98 11 Ftg/Foundatiori/Piers PK NR WILL RECALL 5/29/98 11 Ftg/Foundation/Piers PD AP LITE POLE BASES 5/29/98 34 Rough Electric PD AP 5/19/98 31 Undergcound/Conduit-Wirin PD PA 5/14/98 31 Underground/Conduit-Wirin PD PA 5/13/98 12 Steel/Bond Beam PD NR 3/4/98 11 Ftg/Foundation/Piers PD AP 3/3/98 11 Ftg/Foundation/Piers PD AP 3 AT BEGINNING 3/3/98 31 Underground/Conduit-Wirin PD AP 3/2/98 31 Underground/Conduit-Wirin PD NR 1/6/98 31 Underground/Conduit-Wirin PD AP 12/31/97 11 Ftg/Foundati6n/Piers PK PA 8 LIGHT BASES -ON PLAN 12/16/97 31 Underground/Conduit-Wirin PD AP 12/12/97 11 Ftg/Foundation/Piers PD AP 12/12/97 14 Frame/Steel/Bolting/Weldin PD we 12/12/97 34 Rough Electric PD AP 12/5/97 31 Underground/Conduit-Wirin PD AP 11/24/97 11 Ftg/Foundation/Piers PK PA 7 LIGHT STD'S 11/21/97 11 Ftg/Foundation/Piers PK -PA 12 LIGHT BASES 11/19/97 11 Ftg/Foundation/Piers PK PA 2 LITE POLES MARKED ON P 11/19/97 11 Ftg/Foundatio!i/Piers PK NR COULD NOT FIND SUPT & Monday, May 17, 1999 Page 1 of2 ,. • 11/19/97 31 Underground/Conduit~Wirin PK PA 11/19/97 31 Underground/Conduit-Wfrin PK NR COULD NOT LOCATE WORK AR 11/13/97 31 Underground/Conduit-Wirin PD CA 11/7/97 11 Ftg/Foundation/Piers PK PA AS NOTED ON PLANS 11/6/97 31 Underground/Conduit-Wirin PK Pl MOSTLY COVERED W/0 INSPE 11/5/97 31 Underground/Conduit-Wirin PK NR JOB INACCESSIBLE 11/4/97 31 Undergrour:id/Conduit-Wirin PD co COULD NOT LOCATE CONTRAC 10/31/97 31 Underground/Conduit-Wirin PK PA PARKING LOT LIGHT CONDUI Monday, May 17, 1999 Page 2 of 2 .-· Citv 01 Carlsbad ~ ; Final Building IDSDICliOD. """!'"" ' . . Dept: Building Engineering f(fion1i~n·g CMWD St Lite Fire Plan Check#: Date: 2/5/99 Permit#: Project Name: C8971460 LEGOLAND OUTER PARK Permit Type: COM ·Sub Type: PARKING LOT AND LIGHTING Address: 1 LEGO DR Lot: Contact Person: JERRY Phone: 7609300099 Sewer Dist CA Water Dist: CA •.••I I I I I 111111I1111 Ill I II I I I I I I I I I 1111111 I I 11 I I I I I Ill.II I I I I I 11 I .i I I I I I 1111 II II I Ill I I I 11"1 I Ill I II I Ill I I I I I I I I 9 I Ill II I Ill I I I I I I I I I Ill I Ill II I I I I I I I I I I II II I I II I Inspected Date "2-.Or _qq Approved: By: M1 Inspected: v Disapproved: __ Inspected Date By: ll'lspected: Approved:. Disapproved: __ Inspected Date By: Inspected: Approved: Disapproved: __ ··································································································································•i!••····················· Comments: _______ __,..--------,-..-,----------,-------- PLANNING DEP AJlTMENT FINAL INSPECTION CHECKLIST ROUTIN~ BLDG. __ v_ , M. HARDY ?}ll/--'I-?' "I PLANNER-- LBLACK. __ MBLACK 71_ , ,.- M. HARD-t:::lJ:Yt ... .,,c.,;> BLDG __ _ -. . ~- Project Name: LE60L4NJ) ou_n,e 7>Ae,.K' Plan Check No. CB q'7 Jl-/t,C) Address: I lEGo "7;:>R.... _ --Project Number: Project Planner: Extension -- Contact Person Phone No. -Drawing No. Inspections Final Inspection ltems 1st 2nd Approved All Items below Conform with Approved Site Plan . . . . . . ' 1. Project Planner confirms conditions are met . 2. Building elevations 3. Building materials ---- 4. Building colors 5. Roo:ft;Qp equipment screens 6. Fence/wall height, location, and materials --- 7. Size, number and location of parking spaces . compact, regular, handicap_ 8. Outdoor recreatio:n facilitie~ -- 9. Employee eating areas - 10. Trash enclosure and location 11. Pavement treatment_ ----- 12. Landscaping installed (under separate contract} - LIST BELOW ANY ADDITiONAL ITEMS REQUIRING SPECIAL ATTENTION BY MIKE BLACK: 13. 14. ---- 15. 16. - · 17. -- Project complies with all conditions, including above-listed items. Final inspection is complete. VV(1J (J -~ .qa, Mike Black :Date ---- (H:\ADMIN\COUNTER\Final Insp Cheek) 02/03/99 0 Citv of Carlsbad ~ ·~ Final Building Inspection •• <9\y1.... ... , Dept: Building Engineering Plann'ing CMWD . St Lite Fire Plan Check#: Permit#: Project Name: Address: Contact Person: Sewer Dist: C8971460 LEGOLAND OUTER PARK PARKING LOT AND LIGHTING . 1 LEGO DR JERRY Phon~: 7609300099 CA Water Dist: CA Date: 2/5/99 Pernii!Type: COM .Sub Type: Lot: I 111111111 I I I I I 11I1111111 I I I I I I I II 11,1111,11111 II I I II 11111 I I I I I I I I I I I I I I I I II l'i 1111 II I II I I 11111 II Ill I I I l~I I I 11111 I Ill I I I I I I I I I I II II I I I I Ill II I ii I 111111 II I I II ~-----Approved: ___ Disapproved: __ Inspected Date By:--------~-Inspected: ____________ Approved: ___ Disapproved: __ ................................ ··············· ··············i!~····~· ············· ......................................................................... . Comments:-------------------------------------------------- .- l . . -./ - ., Citv of Carlsbad ~ ·; Final Building Inspection " ··-.:r,----~ Dept: Building Engineering Planning CMWD • l!lte Fire Plan Check#: Permit#: CB971460 Project Name: LEGOLAND OUTER PARK PARKING LOT AND LIGHTING Address: 1 LEGO DR Contact Person: JERRY Phone: 7609300099 Sewer Dist: CA Water Dist: CA Date: Permit Type: Sub Type: Lot; 2/5/99 COM • I I I I I I I 11111111111 I I II I I I I 111 II II II I Ill 1a1ii I II I 111 I I I Ill I I 111 I I I I I I II I I II I I I Ila I~ I I I I I I I I I Ill 1111111 I 11 I I ii I 11111 II 1111 I I I I I~ I I I I.I II j I I Ill I I I I I I I I Ill II I Ill Inspected ~ Date 2-)JQ ~sapproved: __ . By: Inspected: . Approved: Inspected Date By: Inspected:· Approved: Disapproved: __ Inspected Date By: lnspect~d: .. .Approved: . Disapproved: ____ .. I I 11 I 11111 I I I I II 11 I I I 11 I I I I 111 I I Ill I I II iii I I I 11 I I 11 I 11 Ill 111111 I I I I I II I I II II I 1111 II I 11 I I I I II II I II! II I I I I I II I II I II I 1,1111 Iii I I I I 1,111 II I II I I I II I I I I II II 111 II 111 Comments: _____ ....;...a......------------------------------- ~ CitvofCarlsbad · m Final Building Inspection Dept: Building ~ngineering Planning C·MWD St ;Lite diill> Plan Check#: Permit#: Project Name: Address: Contact Person: Sewer Dist: CB971460 LEGOLAND OUTER PARK PARKING LOT AND LIGHTING 1 LEGO DR JERRY CA Phone: 7609300099 Water bist: . CA Date: Permit Type: Sub Type: Lot: 2/5/99 COM :--~0~i~ (c;-,1g nit IE 1~·1. : ··-I\ I n, FEB 11 -i999 H ii ~ . ,_ ; :-i..,, ....................................................................................................... 11!•••••••••••• •!•••••••••••:•-•I!••··········!;!········ Inspected ~ Date L l£r By: K· Inspected: Approved: I __ Disapproved: __ _ Inspected Date By: . Inspected: -'----Disapproved: __ Approved: . Inspected Date By: Inspected: Approved: : -------,--Disapproved: __ 1111II1111111 I I I I 11 I 11 I I 11 I 11 I 111 Ill I 11II11111 I 111 I I II I II 1111 I I I I I I I 1111 I II II II I I I I I I I I I Ill Ill II Ill I I I I I I I I II! I II II II II Ii: I IS II I iii! I II I II Ill I I I I I I I I I II 1111 I 11 Comments: _______ ___,.. ______________ ......,...-"-...,.,...---''---------- EsGil Corporation 'l.n Partnersliip .witli (jovemment for '13uiftfing Safetg DATE: May 19, 1998 JURISDICTION:. Carlsbad PLAN CHECK NO.: 97-1460 PROJECT ADDRESS; 1 Lego Dr. PROJECT NAME: Outer Park SET: III Parklng Lot Lighting -~ANT ~ Cl PLAN REVIEWER 0 FILE ~ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked .by building department staff. D The plans transmitted herewith have significant deficiencies !dentified on.th·e enclosed check list· and should be corrected and resubmitted for a complete recheck. D The check list transmitted herewith is for your information. The plans-are being held at Esgil Corporation until corrected plans are submitted for recheck. · D The applicant's copy of the check list is enclosed for the Jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D Esgil Corporation staff did· not advise the applicant that the plan. check has been completed. ~ Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Gina Yu Telephone#: appt. Date contacted: 5/19/98 (by: kc). Mail Telephone Fax In Person ~ REMARKS: Plans hand:..carried by applicant. By: Kurt Culver for E . .Jensen Esgil Corporation 0 GA O CM O EJ O PC Fax#: Enclosures: trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 ~/ I . ., • -I' EsGil Corporation Profession.a{ PCatt: ~View 'Engineers DATE: July 17, 1997 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1460 PROJECT ADDRESS: LEGOLAND PROJECT NAME: Legoland "Outer Park" SET: II ' a ANT EVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction;s building codes. ~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identit"ied on the .enclosed check list and should be corrected and resubmitted for a complete recheck, D The check l.ist transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been s·ent to: ~ Esgil Corporation staff did· not-advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted. : ) Fax #: Mail n Person ~ REMARKS: . e~e "OWNER II" sheets should be slip sheeted into the "OWNER I" set. Similar! · e "C II" set ~urrently at the bl:lilding department s~ould be slip sheeted into the "CITY I" set. The architectural plans must have all sheets signed/sealed. By: Kurt Culver Enclosures: , E_sgil Corporation 0 GA O CM O EJ O PC 7/10/97 tmsmtl.dot 9320 Chesapeake Drive, Suite ios + San Diego, California-92123 + (619) 560-1468 + Fax (619) 560-1576\ . ' \ I . EsGH Corporatio'n DATE: 1/26/98 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1460 PROJECT ADDRESS: Legoland PROJECT NAME: Professional Pfan !l{_tWiew ·'F,ngineers SET: II CANT . REVIEWER CJ FILE D The plans transmitted herewith have been corrected where .necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply_ with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. · ~ The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. D The applicant's copy of the check list has been sent to: D Esgil Corporation staff did not advise the applicant that the plan check has been completed. ~ Esgil Corporation staff did advise the applicant that th.e plan check has been completed. Person contacted: Christopher Rooney Telephone #: Date contacted: d2u/<rE-(by:fA.X) Fax #: 310 453 2052 Mail Telephone D REMARKS: Faxv-In Person By: Eric Jensen Esgil Corporation D GA D CM D EJ D· PC Enclosures~ 1/15/98 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (619) 560-1576 I. Provide a light fixture schedule for the fixtures refetenced to be installed with this plan set. What is the significance of the "darkened" pole fixtures VS. The "lightened" fixtures? No explanation of darkened VS lightened fixtures. If different styles signify an emergency system VS normal power supply differential, .the conduit installation will required to be revised. EsGil Corporation Professiona( Pfatt. ~view 'Engineers DATE: 12/5/97 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1460 PROJECT ADDRESS: Legoland PROJECT NAME: Outerpark electrical SET:I ·o FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith Will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. · r:g] The check list transmitted herewith is for your information. The plans are being held ·at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check :tist is enclosed for the jurisdiction to forward to the applicant contact person. · rg] The applicant's copy of the check list has been sent to: faxed to Ms.Kyoko Adachi w/HOKArchitecture D Esgil Corporation staff did not advise the applicant that the plan check has been completed. rgj Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Ms. Kyoko Adachi Date contacted: 12.-L:5 f '11-(by: fA.X) Mail Telephone Faxv""" In Person D REMARKS: By: Eric Jensen Esgil Corporation D GA O CM O EJ O PC Telephone#: Fax #: (310) 453-2052 Enclosures: 12/3/97 trnsmtl.dot 9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619) 560-1468 + Fax (6~9) 560-1576 + JURISDICTION: Carlst>ad + ELECTRICAL PLAN· REVIEW + 1993 NEC DATE: 12/5/97 + PLAN REVIEW NUMBER: 97-1460 -Outer Park -Parking lot lighting + PLAN REVIEWER: Eric Jensen This plan check is for the "Outer Park'' parking lot lighting, the Ticket Kiosk's, and the parking lot "site lighting". 1. The parking lot relay/panelboards, both East and West, describe the grounding-electrode system at their respective locations. 2. Where do the above referenced panelboard feeders disappear to on sheet E112? Show the origin of the feeders to the two panel boards on the plans. 3. Provide a light fixture schedule for the fixtures referenced to be installed with this plan set. What is the significance of the "darkened" pole fixtures VS. The "lightened" fixtures? 4. Note 2 on various plan sheets reference Gallego's lighting design sheets for "specifications .. .for mounting requirements". Cl'early specify where on the above plan sheets these details are provided. Note: Any details pertinent to this installation should be included with this plan set. · 5. Where on the site pl;:ms provided in the "Outer Park" set are the circuits referenced on sheet 01 00-E402 utilized? If part of this permit,_ provide circuit identification and locations of fixtures. 6. Sheet O201-E201, Show the grounding electrode system for the individual Kiosk. 7. If the "Mini-power zones" installed in each Kiosk are panelboards, detail compliance with NEC 110-16: 6'6" high X 30" wide X 36" "in front of'.. · 8. The two circular areas shown adjacent to the park entrance, are they fountains or planting areas? Note: If you have any questions regarding this electrical plan review list please contact the plan reviewer listed above at (619) 560-1468. To speed the review process,·note on this list ( or a copy) where the corrected items have been addressed on the plans. VALUATION ANO PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Eric Jensen PLAN CHECK NO.: 97-1460 DATE: 12/5/97 BUILDING ADDRESS: Legoland BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: UILDING PORTION BUILDING AREA VALUATION VALUE (ft.2) Ml,JL TIPLIER ($) 3 hours plan check $261.45 @ 87.15/hr. .. .. . Air Conditioning Fire Sprinklers TOTAL VALUE .. D 199 UBC Building Permit Fee D Bldg. Permit Fee by ordinance: $ D 199 UBC Plan Check Fee D Plan Check Fee. by ordinance: $ Type of Review: D Complete Review D Structural Only x Hourly D Repetitive Fee Applicable x Oth9.r: Electrical Ohly Esgil Plan Review Fee: Comments: $ 261.45 Sheet 2 of 3 macvalue.doc 5196 EsGH Corporation Professional P.[an. !f&-view 'E;ngineers DATE: June 11, 1997 JURISDICTION: Carlsbad PLAN CHECK NO.: 97-1460 SET:I PROJECT ADDRESS: LEGOLAND PROJECT NAME: Legoland "Outer Park" D~NT cg JUPJ& PLAN REVIEWER D FILE D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. D The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. D The plans_ transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. · [Z] The check list transmitted herewith is for your information. The plans a.re being· held at Esgil Corporation until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdicti.on to forward to the applicant contact person. [Z] The applicant's copy of the check-list has been sent to: faxed to HOK Studio E · (310) 453-2052 rgj Esgil Corporation staff did not advise the applicant that the plan check has been completed. D Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contaqted: Telephone#: Date contacted: . (by: ) · Fax·#: Mail Telephone · Fax · IA Person [Z] REMARKS: · Miscellaneous site construction. By: Kurt Culver Esgil Corporation D' GA D CM D EJ -0 PC 6/5/97 .· Enclosures: trnsmtl.dot 9320 Chesapeake brive;· Suite-208 + San.Diego, California 92123 + (619) 560-1468 · + Fax (619) 560-1576 '----····--------------------·--··--. ... Carlsbad 97-1460 June 11, 1997 GENE~L -PLAN CORRECTION LIST JURISDICTION: Carlsbad PROJECT ADDRESS: LEGOLAND DATE PLAN RECEIVED BY ESGIL CORPORATION: 6/5/97 · REVIEWED BY: Kurt Culver FOREWORD (PLEASE READ): PLAN CHECK NO;: 97-1460 DATE REVIEW COMPLETED: June 11, 1997 This plan review is limited to the technical requirements-contained in the Uniform · Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy cohservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Oepartment, Engineering Department or other departments. The following items listed neec;I clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 1-06.4.3, 1994 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law., 1. Please make all corrections on the original tracings, .as requeste·d in the correction list. Submit three ~.ets of plans for commercial/industrial projects (two sets ·of plans for residential projects): For expeditibl)s processing, corrected sets can be submitted in one of two ways: 1. Deliver all .corrected sets of plans and calculations/reports directly to the .City of Carlsbad Building Department1 2075 Las Palmas Drive, Carlsbad, CA 92009, (619) 438- 1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculatrons/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments: NOTE: Plans that are submitted directly to-EsGil Corporation only will not be· reviewe·d by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. · · 2. To facilitate rechecking, please identify, next to each item, the sheet of the ,Plans upon which each correction on this sheet has been made and ret~rn: this ;·sheet with the revised plans. . . . . . :. . . . . . ·:·. -~- Carlsbad 97-1460 June 11, 1997 . 3. Please indicate here if any changes have been made lo the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not r.esulting from this I. t? . IS . D Yes CJ No 4. Regarding the kiosks on sheet A201: a) Provide a foundation plan for them .. b) Provide evidence of State approval or compliance With UBC Section 1704. c) Provide access to and within them for the physically disabled. Title 24. 5. Regarding the signage portion of these plans: :Provide _a general note stating that the disabled access provisions of Title 24_ will be satisfied. 6. The architectural plans must be signed/sealed by a licensed archit~ct. 7. The jurisdiction has contracted with Esgil Corporation located at ~320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Kurt Culver at Esgil Corporation. Thank you. Carlsbad 97-1460 June 11, 1997 . VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PREPARED BY: Kurt Culver BUILDING ADDRESS: LEGOLA?i'P BUILDING OCCUPANCY: BUILDIN<3 PORTION BUILDING AREA (ft. 2) .. ' . .. .. Air Conditioning Fire Sprinklers TOTAL VALUE .. PLAN CHECK NO.: 97--1460 DATE: June 11, 1997 TYPE OF CONSTRUCTION: VALUATION VALUE MU.ltlPLIER ($) ' 0 D 199 UBC Building. Permit Fee .0 Bldg. Permit Fee by ordinance: $ D 199 UBC Plan Check Fee D Plan Check Fee by·ordinance: $ Type of Review: D Complete Review D Structural Only D Hourly D Repetitive Fee Applicable D Other: Ssgil Plan Review Fee: $ O Comments: No Esgil service fee for this review. Sheet 1 c;>f 1 macvalue.doc-5196 · . , .. .s .sa .s ~ t'l t'l ~~~ .c .c .c :jj; ~ ~ -t5 ~ ~ Q) Q) Q) .<:: .c .c PLANNING DEPARTI\IIENT BUILDING PLAN CHECK REVIEV\/' CHECKLIST Plan Check No. CB 97--/L/£]:J Planner LJor7 Ney APN: 2//-/cx;,_ ... Qq Ac;Jdress _____________ _ Phone (619) 438-1161, extension L/l/9"6" : Type of Project and Use: L£wLA:tVd Our;ti;~ ,l)Aze_K Zone: c-T-9 · Facilities Management Zone: -,----1.._.8: ...... -------------'---'------ CFD/cin}out) # ----'-'---------'--,-,---,----_,/ 'cifu1e One !If property in, complete SPECIAL TAX CALCULATION WORKSHEET provided by Building Department.) Legend u f.) f.) i":71 j j j ~ Item Complete a. a. a. Q" Item Incomplete -Needs y_our action _ ~ %1 Environmental Review Required: YES / NO __ TYPE ___ _ DATE OF COMPLETION:-~-~------ Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Reqi.iir~ . . YES ~ ~O . _-TYPE . . · ~c. . 4t;>&3 rt/Q8q--. 4-/6--97 ------'-,--- APPROV AL/RESQ. NQ.C.C,~o/7-b:ZO OAT.E s---20-97 PROJEGT NO.· . .S~,,O 96-It/-_. . . . , ' OTHER RELATED CASES: --=C"-'-"Ll~/J----"Z-=b''----'-/~ _______________ _ Compliance with conditions or approval? If not, state conditions whic.h require action. . . Conditions of Approval ,q~J~; ~~nt7~?f>4 8, % f4 13,, IS ~ .. -~ /!c. £es;, ~08t/ c.ondi±ico L./, W ~ Coastal Zo.ne ;;s~es~n\~itt/Compliilnce ProJect site located in Coastal Zone? YES . V NO. __ If NO, proceed with checklist; if YES, proceed below. · · Determine status (Exempt or C:oastal Permit Required): If Exempt, ·proceed with checklist; if Coastal Permit required, hold building. permit until Coastal Permit issued. Coastal Permit Determinc;ition Form already completed? YES NO If NO, complete Coastal Permit Determination Form no\l\ii. Coastal Permit Determination Log #: . C{J/J 96---'-----,-/6=-··· -~-I/Wed Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Comp'le~e Coastal Permit Determination Log as needed. ... W );(~ lnclusionary Housing Fee required: YES NO / )A{ (Effective date of lnclusionary Housing Ordinance -May 21, 1993.) Site Plan: 1 . Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improveme,~t~, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor's parcel number. Zoning: 1. Setbacks: ,() t' fl"}e.¥1 s ~Oy'I 01"'1 fJkr~ Front: Required Shown Int. Side: Required Shown Street Side: Required Shown Rear: Required Shown 2. Lot Coverage: Required Shown 3. Height: Required Shown 4. Parking: Spaces Required Shown Guest Spaces Required Shown Additional Comments_...;;::,$e=->,e_.__a~,f/-q........._."·=c/2~ec/""""--__.,di ........... ea:a.....=e.a....,+.__ ________ _ DATE 8°,..2(;-9'7 ! Plan Check No. CB 97-1460 -LEGOLAND Outer Park Planning Department 2nd Plan Che~k -July 15, 1997 Additional Comments: 1. Revise the drawing index sheet to accurately reference only those sheets included in the plan set. 2. For plan check purposes please resubmit a full plan set for all items for which a permit is requested with future plan check submittals. 3. Submit a separate sign permit application as required by condition number 80. The application can be obtained at the Planning Department Counter. The sign permit exhibits should contain the following: a) A single sheet showing the location of all proposed outer park signs as was done on Sheet OP 123 of the approved SDP exhibits. Sign details can be on additional sheets. b) Provide dimensions and sign area calculations for each type of sign. c) · Provide a sign area calculation table consistent with sheet OP 123. The quantity of each type of sign proposed-must be included in the sign table. · 4. The proposed light pole signage is different from the size approved with the SDP. The calculation required m item 3 above will determine if the new design can be accepted., 5. Specify the color of the light pole, light fixture and concrete foundation for the pole lights. The color is required to be neutral. Show all outer park light locations on a single sheet. 6. Specify that the vinyl coated chain 'link fence and the steel picket fence are both to be black in color. 7. Specify the flag pole color proposed. The. pole color must be neutral in color. 8. The entrance to the employee parking lot is required to be gated. Refer to SDP approved sheet PW00S. 9. On drawing number L099 please revise the phase line to show that the 31 parking spaces located in the southwest comer of the parking lot a,re to be constructed as p~ of phase one (opening day). This will m~e the plan consistent with the approved parking lot substantial conformance exhibit. I ., 10. Prior to building permit issuance a mylar of the Substantial Conformance Exhibit for sheet PW00-1 must be submitted and approved. 11. On drawing number A201 remove the note on enlarged elevations 4 and 5 which refor to the banner structure as being on the landscape plans. The banner structure should be included on the sign plan. City of Carlsbad . . . 97161 Fire Department • Bureau .of Prevention Plan Review: Requirements Category: Date of Report: Wednesday, $eptember ~. 1997 Building Plan Check R~viewed by: Contact Name Kyoko Adachi Address 1655 26Tf:I st ----"----,-----------~---,--'-- City, State Santa Monica CA 90404 Bldg. Dept. No. CB.~7-1460 Planning No. Job Name Legoland/Outer Park Job Address----~--------~--~ Ste. or Bldg. No. ____ _ ~ Approved -The item you ha.ve submitted for revi~w has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore any changes to these items after this dc;1.te, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply wit~ instructions in th_is· report can result in suspension of permit to construct or install improvements. D Disapproved -Please see the attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to tllis office for review. For Fire Department Use Only Review 1st. __ _ 2nd._·-~-3rd __ _ Other Agency ID CFD Job# __ 97_1_6_1 __ File# ___ __,_ 2560 Orion Way • Carlsbad, California 92008 • (619) 931-2121 City of Carlsbad _ _ __ 97161 Fire Department • 'Bureau of Prevent.ion Plan Review: Requirements Category: Building Plan Check Date of Report: Thursday, July 17, 1997 I Reviewed by:__._V]~:::K__-'--=-_A...........,...r~~~-- Contact Name Kyoko Adachi Address 1655 ~6Th st -~--'----------------- City, State Santa Monica CA 90404 Bldg. Dept. No. C-1397-1460 Planning No. Job Name Legoland/Quter Park Job Address ---------'----~-----~ Ste. or Bldg. No. ____ _ ~ Approved -The item you have submitted for review has been approved. The approval is based on plans; information and/or specifications provided in your submittal; therefore-any changes to these items after this date, including field modifica- tions, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to construct or install improvements. D Disapproved -Please see tft$-attached report of deficiencies. Please make corrections to plans or specifications necessary to indicate compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. For Fire Department Use Only Review 1st. __ _ 2nd __ _ 3rd. __ _ Other Agency ID CFD Job# __ 97_1_6_1 _~ File#_--'--- 2560 Orion Way • Carlsbad, Califorhia 92008 • (619) 931-2121 I I I HELLMU;TH, OBA TA+ KASSABAUM, INC. 1655 26th ~treet, Suite 200, Santa Monica, California 90404 Voice 310 ~53 0100 Fax 310 453 2052 ~T~OIOE Memorandum Project Legoland Carlsbad, Inc. Date January 14, 1998 Project Number 96.0634.00 File Lld Attention Mike Peterson, Carlsbad Planning and Community Development From Christopher Rooney, AIA Regarding Outerpark Electrical Plan Corrections Copies To Kirk Rose HOK/LA, Gaston Laguna HOK/LA, Kyoko Adachi HGK/LA, Martin Zurauskas Lego, Bill Pridgen, Lego, Steve Methot/BBC, David Cattle/Lego, David Ryan/ PSI Mike, These are the electrical drawings for the Outerpark complex Plan Check no. C:8 97-1460. Please proceed with the review of these electrical plan check responses. We appreciate your continuing support and assistance in processing this cluster. This package includes electrical drawings as indicated on the attached sheet index. No shell permit is being requested for this cluster. The following items are included with this package: 3 sets of Blueli,ne Electrical drawings 3 sets of plan check correction responses Please proceed with reviews as required. Sincerely, ~~ . Chrisrophe,c Rnone~ Lucci & Ylssociates, Inc. Consulting Electrical E:ngineers . LETTER OF TRANSMITTAL Date: January 10, 1998 L&A Project Ng: 97-960-0 To: Chris Rooney Proj~ct: tegoland California Outerpark HOK Architects Legoland Site Office 5342 Armada Drive Carlsbad, CA 92008 (760) 804-8355 ext. 103 WE ARE SENDING YOU [x] Attached .[ ] Under separate covet . VIA: [ ] Reg. Mail [x] FedEx [ ] Hand Delivery []Courier THE FOLLOWING ITEMS: [] Bond [x] Bluelines [x] Vellums [ ] California Overnight [ ] Specifications [] Copy of letter [] Change order [] ___ .aaP-==lan=-C=h=e=ck=S=et___,_(-=24..:....<-) D==-;ra=wt=·n=g=-s-=T=ot=al=-------...--------- ANY USE OR REUSE OF ORIGINAL OR ALTERED CAD DESIGN MA,TER!ALS BYCLIENT;AG~ OF CLIENT, OR OTil)lR PARTIES WITHOUfTHE REVIEW AND WRl'ITEN APPROVAL OF DESIGN PROFESSIONAL SHALL BE AT THE SOLE RISK OF CLIENT. FURTIIERMORE, CLIENT AGREES TO DEFEND, INDEMNIFY, AND HOLD l;JESIGN PROFESSIONAL HARMLESS FROM ALL CLAIMS, INJURJES, DAMAGES, LOSSES, EXPENSES, AND ATIORNEY'S FEES ARISl'NG OUT OF THE MODIFICATION OR REUSE OF TllESE MATERIALS. -... I CoEies I Date I N:o. I DescriEtion . .. I. Revision * 01/08/98 · 0100 00 E00l Symb9ls List and Abbreviations * 01/08/98 Ql0000E0b2 Symbols List and Abbreviations * 0l/08/98 0100 00 E400 Lighting Fixture Schedules 1 * 01/08/98 0100 00 E401 Wiring biairram * 01/08/98 0100 00 E403 Panel Schedule 1 * 01/08/98 0102 00El0l Lighting, Power & Sima! Plcl1' . 1 * 01/08/98 · 0102 00 E102 Lighting, Power & Sima! Plan 1 * 01/08/98 0102.00 E103 Lighting, Power ·/JJ, Sima! Plan 1 * 01/08/98 0102 00 E104 Lighting, Power & Sima! Plan 1 * 01/08/98 0102 00E105 . Lighting, Power & Signal Plan 1 * 01/08/98 • 0102 00 E106 · Lighting, Power & Signal Plan 1 * 01/08/98 0102 00 El07 Lighting, Powei: & Sil?!lal Plan 1 - * 01/08/98 0102 00 E108 Lighting, Power & SimalPlan· l * 01/08/98 0103 00E:109 . Lighting. Power & Sfonal Plan 1 - I 3251 Corte Malpaso, #511 Camarillo, CA 93012-8094 Phone(805)389-6520 FAX (805) 389-6519 Lucci & -Ylssociates, Inc. Consulting Engineers /~ies Date No. Description Revision * 01/08/98 OIQ3 00 EllO Lighting, Power & Signal Plan * 01/08/98 0103 00 Elll Lighting, Power & $ignaJ, Plan. - * 01/08/98 0103 oo Ell2 Lighting, Power & Signal Plan .. * 01/08/98 Oi0300 Ell~ . Lighting, Power & Signal Plan * 01/08/98 0103 00Ell4 Lighting, Power & Signal Plan * 01/08/98 0103 00Ell5 Lighting, Power & Signal Plan , * 01/08/98 . 0103 00 Ell6 Lighting, Power & Signal Plan * 01/08/98 · 0103 00 E117 Lighting, Power & Signal Plan * ,01/08/98, 0103 OOE118 Li.e;htin.e;, Power & Signal Plan * 01 /()~/02 {)')()1 ()() l=/?01 Dn.-L-,na T;,-1,pt T(',,,..,t,. T._;aht1na D,,.,.,o.-Jlr _C,'"'.-.1 'Dinn THESE ARE TRANSMITTED as checked b(!low: [] For approval [ J Approved as submitted [ ] For your use [ ] Approved as noted [x] As requested [ ] Returned for corrections [ ] Resubmit_ copies for approval [ ] Submit_ copies for distribution [ ] Return ___ qorrected prints 1 1 1 1 1 1 1 1 1 1 [] For.review and comment [] -----------------------------------,----- *REMARKS: (1) each reproducible and (5) each bluelh1e$ stamped and signed~ COPY TO Ken Lucci; File 97-960-0 SIGNED_~----------------------- J:\ WPDOCS\TRANSMIT\97-960\0uterpark 2 -- •4 TIES e 12• O.C. VERT. RE INF. FER SCHED. --~0 LIGI-IT FOLE, 6A5E re .t A.-6. 's FER FOLE VENDOR- ON 1112• NON-51-!RINK GROUT --------. .3 -•4 TIES CONC. FTG. 6ASE re .t FTG. . (f\ ~ 5 :ff • I: :c w • & t w Q AUG 1 0 1998 City of CARLSBAD BUILDING DEPT. l "D" l 1 DIAMETER 1 IIOOTINCr. 60Hll0UUI TYF5 'D' ·~· \/ER!. ~!!IF. A I&' 41-61 6 .-115 e 2-4' 6'-(!)' 6 -'6 C 24' ,4'-6i 6 -'6 L.IG+-JT t=OJ..E P:OUNO.ATI ON SCALE: .3/41 = l'-~1 ..... hr&Jz Martin & Dunn, In~. Dak&No. ...... No. Daa ~iena IDz ~Not LEGOJID • Slttll~ P-000 00 1611 08-03-98 lliw-& Hit 06-12-98 Obeia+ C.AlltL.SBAP l"nMII , ... lnldal~O... 10-17-97 S120 ¥-!.,.. z I- cc <:( ~ z I- ~ MARTIN & MARTIN, INC. Structura I & Civil Engineers ~ 7801 Mission Center Ct. #400 San Diegb, CA 92108 Phone (619) 497-2118 Fax (619) 497-0429 STRUCTURAL CALCULATIONS \ \ FOR Legoland Carlsbad (Martin.& Martin Project No. 960240.00) Parkwide Area Development Light Pole Foundations Architect of Record: Hellmuth Obata & Kassabaum For Bu.lletin No. 611 August 3, 1998 MARTIN & MARTIN, INC. Structural & Civil Engineers 7801 Mission Center Court Suite 400 SAN DIEGO, CA 92108, Phone (619) 497-2118 Fax (619) 497-0429 \ ,, lf JOB LS10 lh.J.?A SHEETNO.--~-' ___ OF_7-'-· -~-- CALCULATED BY ~---0 iJ----'--_ --DATE 1 I q ~ CHEQKEDBY....,.. ________ DATE ____ _ · 1'l f Ii \J \ F \~flt Ow ~ I b Ff '89 l£. G-OVeµJ~ FOf2--f:P...OJP Fl'f\\J~ WG-T -=-3, '2. a. U~ ':oat M.LtJlM.vV\ pot.£ '0Gl' = /.11 ~ Pl?OJf.a© w tt'.M ~ ; '>1..! --JL ) Pout = (4/12.) Y..l ~ =-'5, ~ s;, (p Pr 2.. ,A f2 ~'2... l. Fl 'ft"Jv--r-:: 01 (a r-1 V',G 2 Pl' M.l'~ , f:::: C I(fiJJf ::: ,,4 i-/ .O~ , T\ '/. lf-{f ~ r ?'l\t../f .tt: r f .::: . , )( c;o =-\ :> -~ Ff .::. , 1, '1-nt ~ '"=' 1 ~ . 'F,il\Jvli. <::;~vv'''p.,'' \NClv(CS t=,\tTVU 1'1~: Af.:;.1 A7 1 0\,l, 0?,I, O<.o, on,,, 01'2..11 i;,v1,csP-e,t1 C.tJ-D t, ~Nv1 Ci-LI --,,.,..• .......... ;-·-· .... i .. ·~--t: ~--·-.-~ ;:--~ MARTIN & MARTIN, INC. Structural & Civil Engineers 7801 Mission Center Court Suite 400 SAN DIEGO, CA 92108 Phone (619) 497-2118 Fax (619) 497-0429 JOB LE.GO( µJ.JJ SHEET NO. ___ __;_Z_~--OF----,,---- CALCULATED BY --"'-----'[)"-'vJ'---. __ DATE '7 l ~'B:, CHECl'\EDBY _____ '---_DATE ____ _ ,, \I fl 'i°f\Jtf &/ZB.J'f A -lb.~ fl NJ1tt1 ~ot-J ~1,b.,,__fPv-J Pre2-~iJ:bf.;10 N ~ ~ (\+Ji + 4.~h/ A= 1,'>i-\\) 'S.1 b {\ .= t.; 4-~ t<?% - ??O"il?~il, \ 6 = ,2/:Y:1 ( I \- i.. \i ff ff ~ b = Is =-1, c:; ) ~ = ?> ,. ? '1 0, ~°) l ------· --I I 1-+ 4. Yo~ n. ir) =-2,~ .'-~,s ~ ·~1 h \ ll 0~ re: \.~ Q) pifEE rON \N/ D == 4 ·-~ . i JOB LSGO[p,.)Jf) MARTIN & MARTIN, INC. Structural & Civil Engineers 7801 Mission C.enter Court Suite 400 SAN DIEGO, CA 92108 SHEETNO. ____ .,, __ ,__,_ OF ___ ----''-- Phone (619) 497-2118 CALCULATED BY --~O_v-J __ -DATE 1l6'6 Fax (619) 497-0429 CHE<';KEDBV _______ DATE ____ _ r\'1CTIJ(2..f &~f v B \/ C::fWJP t~CLIJ)(.$ Ft1~t Tif?fl.S 05, 0~ ,010 A~O 0/":>, ~ ' . T'l () e . O ~ F\ -1-··pil.{l. v-1 t ru ~ { i"''fJO 5 0+1 ~ 2. r:, ~ Pol£ c;ovrt,; .s. , \ ": * F\ Y.fV{L\fz. \tN,T::.. 50"-3> ~ 1'?0 ~ 1r o ce w (, r = ti'~ ~ ~, 1:; 6 'l z t:> i-t b" f CF .::. \:>4, 2. s H 1-00 144 1)1'2o~f_c:.71u' wrM AU.A : ?~ =-~/12-)X"-'? .::..\ Z.1S S.A--j 14 Pr'- I F W~ · :::. 2, o r:r 7 'I-'2, :=.. b, o Fri.. at ~~lS.U..l(: ff :;; , :, Y.. l~ ~ 4'? ~ Fr';: , "?~ lw ~ ,,~ Ff..:E! ~ = ~?)( 2b,'2.\-+ ??~ l'>,15""=-{\,12,'? Wl\J-D: Ce=-Ll~ p-=w~!rl~lrlr,;:: '2...lPSF ~ f F .=. 2-l "/. Co, c :: 11 (, Fr= '2-l ')l t 4 ~ '2-t'1)4~ µ:= 11 .. to-,Li.6.1.t + '2.:C\.41P.'lf'.c 1~:,0 Pi""~<-- I\ = 2~ °¼-"~ 2-'~0 ~ o ,C,b '2- S ~ "?-.;.. ~,.o A =--, ?62. 'i{ ( l + J I...., 4,%-i-2.I, tr) ~ 4. ,o, < e;,,.o' ~ z I ')6 )-. . A-s ===-, 0:,5-iC (yA i 2.4: 1... "\... \/ 6 :=. .o ., ~ /1'\ 1.. uWz 11 e-1 As~ 1-f y ~ 1 \ ~ t>~ ~4 d> ~ la FPvJ \NL D = ~ .-o ~ o-~ c, v~-flc,k<.. :: -', • -> -~ 0 •. t -.• .. ..... ~ -~ -• .:, • • ,-~ ~. --• ... • V Oo ~ ~ 0 ~ • 0 ~ ._• '-. MARTIN & MARTIN, INC. Structural & Civil Engineers 7801 Mission Center Court Suite 400 SAN DIEGO, CA 9210_8 Phone (619) 497-2118 Fax (619) 497-0429 JOB ~--L~E:'_-G-_O_L_J>._IJ._1/J _________ _ SHEET NO. _____ 4 ___ OF--~-- CALCULATED BY ___ . _o_(N~· __ DATE "7 / ~ If:, CHEC~ED!3Y _ DATE ____ _ lA b-~ rot£ Fovtl0Nrtvrl.S ----~-----'~------- F,)t]\J'te ~v'-' '' c..:\' ~~f 1N<:.Lvv?l.$ Pt-~Y2-IZ 'f'i{-VlS c.L()-P.:>1 1 C..U~-E>2-A~ tl~-Fl II l/ ii~f .C.LP-t:> \ F 1~ oN A Io Pr ~ G-OJtftl.JS.. \ : if ll f 1~,-uu' \vfr.t = 20, r..-., SJ.1 ~-o r~,t,) ?,1.-cr ~ ~ lf" ~Ole. &JGT = ti' 1', it; -l.lloS "/4,;;:> i--(":).011+4,C,i--?>) = '"',l,o ~H lO) f'2 [O "!L!-2.. ~ltO)iert(J w I~ Mft.>-. ~Pol£ =-~,4 s /11..) 'I. /O =-2,.9 SH ~ rr 12- . F l')LTJvtl -=-Lt, s ~ 'l;, A 7,..- FoA S~T Cl\ , f2..fi,Ff'J2.. TO f)'AV'lli. G~ 1'A '-I C -if' <$~<":;,Mil ·. 1 F = , ?'/-. 70 ,:::. {C, Ff::::.-I ?"f-/09-= 3~ I WIN:0: C.e. = (.Ola f= 2c:n'-/,o<,,//.t:,c.: lOi PSF FF :. l °>Y. 3~0 .::. ~ 1~ :!it Fr ::: Lc>i Y-~ •0 ::. l s1r v-11~{) \)-Ovf1.J:J..s t'J\:::. '?1'i-1r,i.r-+ [:,'L.-;<.6,'2--r~ l5~\ f'ir~ ~~,0~ \\,'2..0,~ P~,v:;.. l'?~1/11iir~ \4l~ \{t '7 b -=.-I 1 ') M 6, .:: ~r ', H 5 / :: ",'7C) 'f '?> SJ 'J:, ::;, 4J 8 ' ' MARTIN & MARTIN, INC~ Structural & Civil Engineers 7801 Mission Center Court Suite 400 SAN DIEGO, CA 92108 Phone (619) 497-2118 Fax (619) 497-0429 .. JOB__::L'-"'S:c..-=.tro-=--::..:('AJJ.---'--'=. lLJ::;__ ________ _ 5 SHEET NO.--,-.-~-----OF ____ _ CALCULATED BY ___ t)_vv ___ DATE , 0-S CHEC~ED·BY _______ DATE ____ _ \ F\'it\'-J~ 1 W v-T -:::: t=:; u .ti. TDft{_ 1-,{J N 11...f vr.l\ Pol1 we,r ~ -o--")l ,1.S ¥-~ '(. 11os..,c12,i.r a::;.\~ sh.,.../ 100 16 I 2 l'l.. ' l ~jfCflii,) Wll-0 ~·. ~Ol-f. ~0/Ji) 'i--!-2,?.f =-d.(\ ~Iv( ~Fr2 Fot ~1LP..:;-c8, ~.£ \l ,, -rJ F"W-~ Gf>-0:lP 'A A~ft-= ~,c,.,zci,'S--rC?=-1,1 ~~ '"½Pf2- rt-1tf 11 'Sif-,(S/.A.l C.: Fp-;:: I ?:,~SO =--l? . 4 ff :;:: I '"'?'/-ltJ"J ::_ ?,-i, ~ IN o ·. () = / O'i PsP ~ F'F~ /C)x 3.::: s, 'la\ Ff .: I 0) 'X t) := I? t lN ' tJ() (fvJ f)..,.µ ) M:: '51)( \?,,'?+ 11??..i-7,-se,::. l'S~OfF'.l Ueou,v = l1,'5f1_ '()f£:~1v ~ l~90 /1'),-<;: t4o * 1\2.'i b ~ 1,S f1 I 6.; '3,S?r S1 ::: "!>Soy~, o/?> :::: 40~ ~ ..:: z.. "l, 4 "' 140 _::: d, ?"f -4 ~ 'I, I,~ ,___ ____ ) 1 . I d = .a,~ ( [ -\-. \~ A,;~-icl~/; :::: '3JO < 3,'") oil y-it l , ,~l-1 -r, I \ \0 MARTIN & MARTIN, INC. Structural & Civil Engineers 7801 Mission Center Court Suite 400 SAN DIEGO, CA 92108 Phone (619) 497-2118 Fax (619) 497-0429 SHEET NO. _______ ..,:to'-----'--OF--,----- CALCULATED BY ___ ..::;....-{)..:......vJ~·~-DATE , I~ e:, CHEC~ED BY------'----DATE ____ _ 9!11:1 . LI 6-t-11 PJLl ~~ferlV~J ~12..0.J\O I I'\ ili~S Ft'lT'JJ2~ T'f PiJ Clf-D4 1 c.U>-P4~ M,.{) CL~-~\. I} ,, . "1'\~E. (. l~ -JJA f I~~ V'/ln-\ \ b-\-f1,:? Q~ At-J ~Pr fCU' \./ \\ 1'-1 ()€-CU.~ -0 4 a.. Pl -qu1,{t.. w l T'd z.. \.\ff.M J o~ ~ ~ ff 11..JLf. i'1Pl? 11 Ctf ·1>,.1 1 ' Ft-Y:iV/.k'. v-i t"G\ \ H-£0 o,-::> A Io f3f '{J::x_g.. OJ,µ.{?11J€. W~~T (}.-~S OF All 7 i1f€.S. ,, \I ll '\/ 'B'{ ~\Jl[t.J ~ Fl'iTvtf &P.o/fs· f\-f> ) ¼.JttJ.0 r_;ovlf!uJ.i fl~ t,J GT :: ZS 4 ( A~--Jy.f:{)) ~!20Jfc'UiPVltJ0 Jf'tY;·. pqy ~("'ti) y.. /o,o :=:: t,~ S)1 ~11' ~ ft'ti"'Jll ::. ~:: I, lll-f 9-w ~ ft.2 .. @Pi.Ct\-/~.,. , 7 \t\~ v-ttN{)1 P·==d°>PSF ~ 'd:I ~ · ff =-I 0) 'i--~ -5'? fp.:: /U; 'l 'f::) =-l5 )- 'H / \f1~[f-L~4 eCC 1 Iv\~ '?'1il\,25 +2.5'1-/,S + l'??'i-b,2f ~ 1'0,ufitia \Jl{2F1'/:i'All.. t,,µ~ ice~ lv\f:.7t-t.H,1.r,p ... + 1?2:'f.6,'2-\::. 2-2.;~ft~ --<- . . i\:. l\~,v:;;. l\/2.S Fr P~v/Vc 22~~1,1,tf ~ 10)e:, 71'2.'\ ~ :::-r,S F1 1 d;>~~ n S, = 3S:::r-t.1\h ~4°t A~ 2, ;4-i )o-,s = o., b ,406 ~,,~ <i-= ·7; 1-l I + I+ 4,3~~1, 2\ )-=-~4 c:_, I t,_'!, .s'~ v I 1\ ij li s~ ,~ cb ft~ Ffltl vJ / 0.::: ~rG %-& .... · s vet:(LC):L ( t • MARTIN & MARTIN, INC. Structural & Civil Engineers 7801 Mission Center Court Suite400 SAN DIEGO, CA 92108 Phone (619) 497-2118 Fax (619) 497-0429 l\ \\ f JOB Lfi:~ 0 tJ.J-14 SHEET NO.~---,----,--~---OF _ __.__,..,. __ _ CAl,.CULATED BY _______ ...._>Q_v'J __ DATE 1 { ~g, CHEC~ED-BY -----,------DATE ____ _ G-l2w~ 1 ~ c L1.1til[) Ft xrw.e: ni?e:s c. c. -P~ F .3 , c.t ~--F¼ , c Lf->-F4 \ At¥J C..lf-'f4a.. II \ . \\ -r-l~f CLP ~F4~ ~t 1% z. L-\ £.Ms oN A /4 Fr P'JLE: &wws ~'I ?€\J 1 ii vJ OF Pt ·-r:,v,tf. 6./loJPS ll ~ \\ -'-' P '' J \.tJ IN O G-DJ f/..1J) ll 4 pt2oJ-rl.CTf'""° w I /)71,~ ~ . '$ ' s ~ lo P€t IT. . ' \k-J/t-\ 0 ~ p =-l°>f Sf Ff ::: I~ --f. l';_ '(.. (o '{. 2.. :: \ \ d \} F (-> = . I °> -{-lt '{.. I Lf --I ? ? ';@ . tv\= 114 '1L l?. 21? .+ I'?~ r' i 2f::: '2.~,6 fTAt , u ~ Me:wtv ~ l 5, 'tC, M f~vlv = ~ 36/ 6.1 \:::. l~G * ,i~ ~ ::-I, e;pj " 0 = 4,0 FT s, ~ ~'SO ..J.4,'i> =-46fo A : 2.,-~4-~·t:'°--=-o, 02,- A ~b -t I,\ ~ :._ I l, z_ '/.. ( \ -t / \ + 4,) (;, il/ ~' ~ r ) z.. ,.~"2_ * 712~ 6 =-1-rO Fr 1 . ~ = 3,C,F, \ I =-:,,C:>4 t.. 4ro oft s, :;; :,$0 1 ~,s /3 = 4ve:i MARTIN & MARTIN, INC·. Structural & Civil Engineers 7801 Mission Center Court Suite 400 SAN DIEGO, CA 92108 Phone (619) 497-2118 Fax (619) 497-0429 \ JOB l,€.,C,Ol..~~ SHEET NO. /-,. \ 3 OF _____ _ CALCULATED BY . M . DATE_._..,-·}_°'\_-~~-- CHEC~ED BY _________ DATE-----'---- ~-µ.OJ0TTL) f\'f-rvi2ft ~\){£ S~No, P...Z... ( . L.EGOLA~D CALJFORKTA Pole Mounted Fixtures :,' Type Quantity Cluster \ ; A6. l 2 D A A6,2 4 D A A6.3 6 n l). A6.4 3 D A A6a.4 1 D A A 7.1 l D A A7a.6a 2 L A A7a.6a}: 0 L A. \ , : ()].lf\ ·, 8 B . A 01.lf 3 C A. 01.1 f ZS 1) A 01.lf 2 F A 01.lf 3 J A 01.lf 2 R A 01.ls 11 B A 01.ls 2 D A 01.ls 6 F A OJ.Is 4 I A 03.lf 2 F A 03.ls 4 D A OSa 2 C B-. 06f 6 C A 0.6f 3 F A ()tim 3 C A 06s 21 C A 08 2 C u 08 2 I> D 08a 9 C B , 08a 6 D B 010 1 ... B 010a 2 F ll O10b 2 J<' B 011.lf 3 B A 011.lf 99 C A 011.lf s· . F :\ 011.is 4 B A (.)11.ls I I C A 011.ls 2 R A 012.lf 2 D A ) CAI.Lt:COS Li~htini Design . pas:c 1 ~------)-----0--- ~-Sffetf,¥l)tt ~?Awlt-k-?-QCA) -0o -S-1 i,o "'C'®[~tt@ (BVLL~nt-1 t-,/o, b~; .... .,7 /' ' . ' ~ L.E-GOLAND CALIFORNIA Pole Mounted Fixtures ~ Type Quantity 013 3 013a 2 Pl 9 P~. i!0 <P2a ¼ P4 f ·p4a 65 P5 ' ' I • 20 \ : T3 i \ 24 _T3 13 T3a 28 Vl 26 Vla 12 Vla 6 Vla 2 CLP-Bl 6 CLP-82 2 CSP-Bl 4 CLP-Cl 1 7 CLP-Cla 2 CLP-D2 . 9 CI.P-D3 12 CLP-D4 10 CLP-Fl 49 CLP-FJ 4 CT.P-F3a ., "' CLP-F4 23 .. CLP-F4a 6 e1::;p.f M.t 4 t:::bP-f M-i it 4 C:bP-IM2 · 7 CZ-Ll 6 CI.P•Rl 4 GALLEGOS J.,ighting Design Cluster \ •, C C Q 0 Q. . 0 ··-0 0 D 1 R D C D ·L B B B C C D D D F F F ·F 'F I J l · " I~ R s~~o .. +,.~ R /. ll (Juhu=par::k · Owterpark Q-u.t.e.J:.})3.J:,K-- Oute-rpark OH-t~1'-- Ou ter-pa.i:-k- A A A A A A A ~~ (W ~ \-\04? D ".> l'\-OW ~A:-(~A) ~ ) :a-C. Ct C. g C /¥c.. A· ® ,_·. ' .. 1998 !'X>f l iv CL, LJfJ\it> 0~3 Page_1_of_ INSPECTION REPORT CLIENT l-@.;O c...~ DATE S -\\-ct '5 Architect ):h;;, \t.... Engineer m A-e-:n ,u INSPECTION _OSHPD _OSA 2--Specialty __ Mechanical __ Electrical __ Roofing '>" Concrete __ Masonry __ Struct Steel __ Prestress Cone __ Pile Driving __ Fireproofing __ Waterproofing __ Non-Destructive __ Soils Technician __ Batch Plant __ Bolt Pull-Out REMARKS J 0 V lfh. t9:1 & MAT'LSAMPLING _._Concrete Cylinders __ Cement __ Mortar Samples __ Grout Samples __ Masonry Prisms __ Masonry Block __ Fireproofing __ Units (block or brick) __ . Asphalt Concrete __ Roofing _. __ Reinf. Steel ___ Steel _, _ H.S. Bolts ___ Tendon (PT Strands) , __ Other __ Other __ Other QTY --·- -- -- -- -- -·-- -- -- -- ------ -- PROJECT (Name)_ kffi-2 o <-!"t:&-d:) (Address) C--1"\ a...L.S ~A L) CA • REPORT NO. Os, C\ ·:z Q'l-C)"'t ... -.'1):;L C' Building Permit No,--'--~.i...7_,__~ .Lf ':t ..... , __..ia"-'o=---------- Plan File No,--,---------------- Govt. Contract No.-'--------------- OSA or OSHPD #------------- 'Other ¢un,:n, PtM::IL L-1G;.ttr Po1....{S"·: ed$GS MATERIAL 'DESCRIPTION INSPECTION CHECKLIST .i.c-Rinf.: Rel;lar A '2! s ~ C:2 g, !i2 Q _ Plan & Specs __ Rinf.: W.W.F. _ Clearances __ Rinf.: Tendons _ Positions __ Cone.: Mix #/psi _Sizes ___ Cone.: Mix #/psi _Laps. __ Cone.: Mix #/psi . _ Future Continuity #/psi ___ Grout: Mix #/psi _ Consolidation __ Mortar: Type/psi __ Mortar Batching __ Units: Block _ Electrode Storage ___ Units: Brick _ Torque Applied __ Steel __ H.S. Bolts __ Metal Decking ___ Electrodes __ Fireproofing _._Other _ Corrective action required __ _ Corrections completed WdS eYhPe\:NL CERTIFICATION OF COMPLIANCE: To the best of our knowledge, all of the reported-work, unless otherwise noted, substantially c9mplies with approved plans, specifications and applicable sections of the building codes. This report covers the locations of the-work inspected only and does not constitute engineering opin- ion or project control. INSPECTOR NAME :::::i'2r-n s,-r--,,L p Y ,~c;.;;,:,.;;;, woma-~~ INSPECTOR SIGNATURE µ_j} 1? -~ PSl·B-900-170(2) CERT. NO. ~e O C; 'e, t -'6~ pATE-,,,.,.~-,~-~r1 __ ,\_--~~~------------