Loading...
HomeMy WebLinkAbout1221 BELLEFLOWER RD; ; CB971196; PermitPermit No: CB971196 05/21/97 11:47 Project No: A9701559 Page l-of 1 Development No,: DEV92002 Joh Address: 1221 BELLEFLOWER RD Suite : Permit Type: SINGLE FAMILY DWLNG - DETACHED Parcel No: 214-542-08-00 Lot#: 44 Occupancy Group: Reference#: CT 92-02 Status: ISSUED D$scP5ption: PLAN 3,PHS 1,3206+665 GAR+SSSF Applied: 04/07/97 : PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN Apr/Issue: 05/21/97 i Valuation: 266,422 Construction Type: VN I Entered By: RMA Appl/Ownr : KAUFMAN & BROAD 619 259-6000 12626 HIGH BLUFF STE 400 SAN DIEGO CA 92130 Plan Check Numbers > ORIG 970369 PCK 970792 *** Fees Required *** *** Fees Collect8&2&@%%&%!.~~ 01 %* -__--__---__--__--_-------_- _______-___-___-,_---_---_--_----~~L_--16(4~~~ Fees: 16,404.80 A Adjustments: Total Fees: Fee description -_______------_---_--- Number of Bedrooms Number of Bathrooms Building Permit Plan Check Strong Motion Fee or Enter Park-in-I Enter "Y" to Autocz Enter "Y" to Autocz CFD Fees Waived(W)I Payoff Fee for CFD * BUILDING TOTAL Enter #IJnits & Code-E Enter "Y" for Plumbind Each Plumbing Fixture 03 Each Building Sewer Each Install/Repair Water Ll Each Water Heater and/or Vent- Gas Piping System. .oo 350.00 16,054.80 Ext fee Data 5.00 3.00 1224.00 796.00 27.00 1575.00 3 4849.00 Y 540.00 Y N 4670.80 13681.80 2400.00 D5/8 20.00 Y 112.00 15.00 7.00 7.00 7.00 2 7.00 14.00 Each Vacucm Breaker > * PLUMBING TOTAL 182.00 Enter "Y" for Electric Issue Fee > 10.00 Y Single Phase Per AMP > 200 .25 50.00 * ELECTRICAL TOTAL 60.00 Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts/Heat Pumps > 2 9.00 18.00 Each Exhaust Fan 26.00 9.00 81.00 Each Install/Reloc Vent x MECHANICAL TOTAL I 1 I 15.00 Y Each Install Fireplace > 2 6.50 13.00 UTYOFCMLSBD 2075 Las palmaf Dr., carfs\#d, CA 9209 (619) 438-1161 i FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971196 PERMIT#: CB971196 PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+55SF PORCH+123 DECK,SAMBI SEASIDE-KAUF" DATE: 10/14/97 PERMIT TYPE: SFD ADDRESS: 1221 BELLEFLOWER RD Lot# 44 CONTACT PERSON/PHONE# : C/HAROLD/9 2 9-1008 SEWER DIST: CA WATER DIST: CA DATE INSPECTED: is!--!qT APPROVED DISAPPROVE- INSPECTED DATE BY : INSPECTED: -I . APPROVED - - - DISAPPROVED - I . FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971196 DATE: 10/14/97 PERMIT#: CB971196 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+55SF PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN I- ADDRESS: 1221 BELLEFLOWER RD Lot# 44 INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION CDEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971196 DATE: 10/14/97 PERMIT#: CB971196 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+55SF PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN ADDRESS: 1221 BELLEFLOWER RD Lot# 44 CONTACT PERSON/PHONE# : C/HAROLD/929-1008 SEWER DIST: CA WATER DIST: CA APPROVED 1( DISAPPROVED - DATE CD INSPECTED : INSPECTED BY: INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - L FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD WATER PLAN CHECK#: CB971196 PERMIT#: CB971196 DATE: 10/14/97 PERMIT TYPE: SFD PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+55SF PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN ADDRESS: 1221 BELLEFLOWER RD Lot# 44 OCT SEWER DIST: CA WATER DIST: CA CONTACT PERSON/PHONE# : C/HAROLD/929-1008 I51997 INSPECTED DATE BY: INSPECTED: I. APPROVED - DISAPPROVED - INSPECTED DATE BY: INSPECTED: APPROVED - DISAPPROVED - FINAL BUILDING INSPECTION DEPT: BUILDING ENGINEERING FIRE PLANNING CMWD mmm PLAN CHECK#: CB971196 PERMIT#: CB971196 PROJECT NAME: PLAN 3,PHS 1,3206+665 GAR+55SF PORCH+123 DECK, SAMBI SEASIDE-KAUFMA6 DATE: 10/14/97 PERMIT TYPE: SFD ADDRESS: 1221 BELLEFLOWER RD Lot# 44 INSPECTED DATE BY: INSPECTED : APPROVED - DISAPPROVED - CITY OF CARLSBAD INSPECTION REQUEST PERMIT# CB971196 FOR 10/23/97 INSPECTOR AREA PD DESCRIPTION: PLAN 3,PHS 1,3206+665 GAR+55SF PLANCK# ORIG 970 PORCH+123 DECK,SAMBI SEASIDE-KAUFMAN OCC GRP TYPE: SFD CONSTR. TYPE VN JOB ADDRESS: 1221 BELLEFLOWER RD STE : LOT: 44 CONTRACTOR: OWNER: REMARKS: C/HAROLD/929-1008 INSPECT APPLICANT: KAUF" & BROAD PHONE: 619 259-6000 SPECIAL INSTRUCT: TOTAL TIME: CD LVL DESCRIPTION ACT COMMENTS 19 ST Final Structural 29 PL Final Plumbing 39 EL Final Electrical 49 ME Final Mechanical 4 ***** INSPECTION HISTORY ***** DATE 102197 102097 100897 100797 091697 090297 090297 082797 082597 082597 082297 082297 082297 072897 072597 072597 072597 072597 062397 061397 061397 060297 DESCRIPTION Final Combo Final Combo Final Electrical Final Electrical Ftg/Foundation/Piers Interior Lath/Drywall Gas/Tes t/Repa i rs Insulation Exterior Lath/Drywall Rough Combo Rough Combo Exterior Lath/Drywall Rough Combo Roof Sheathing/Ext Shear Shear Panels/HD's Roof/Reroof Shear Panels/HD's Roof/Reroof Ftg/Foundation/Piers Underground/Under Floor Sewer/Water Service Underground/Under Floor DECK ACT INSP COMMENTS NR PD CA PD AP PD NR PD AP PD AP PD AP PD AP NF AP PD AP PD NR PD NR PD NR PD AP PD NR PD NR PD AP PD AP PD AP PY AP PD AP PD AP PD SOUTHERN CALIFORNIA SOIL AND TESTING, INC. 6280 RIVERDALE STREET, P. 0. Box 600627, SAN DIEGO, CA 92 160 (61 9) 280-432 1 Concrete Compressive Strength Test Report File Number: 9712187 Project Title: Collections Project Location: 1221 Belleflower Road Architect: Kaufman & Broad Permit No: 971 196 €ngineer: J LD Plan File No: Con tractor: Kaufman & Broad Location In Structure: Material Supplier: Superior Ready Mix Admixture(s): Time In Mixer (Minutes): 80 Slump, Inches: 4 CC Temp: 0 Truck Number: 391 Ticket Number: 216593 Air Temp: 0 Samples Fabricated By: KE Samples Tested By: JWB Air Content: Lot #44 - Slab-on-Grade Mix Design a tion: 35P K Laboratory Number: Mark: 4 Date Made: Date Received Date Tested Diameter, inches Area, Square Inches Maximum Load, psi Compressive Strength, psi Age Tested, Days Required 28 Day Strength, psi Unit Weight, pcf 8421 I 8422 06-24-97 06-25-97 07-05-97 6.00 28.27 72,000 2,550 11 2,500 07-22-97 94,500 3,340 28 .I Specimen sampling, transportation and compressive strength testing were performed by this agency in accordance with the applicable ASTM standards. This agency makes no other warranties express or implied. Distribution: (3) Kaufman & Broad (1) Superior Ready Mix Reviewed By: George Gah, RCE #56564 06-24d 7/22/97 i SOUTHERN CALIFORNIA SOIL 8z TESTING, INC. 6280 RIvERDAwe STREET, P.O. BOX 6OW7 SAN DIEGO, CI. 92160, Plume (619) 2&0021 c r _L DAILY FIELD ENGINEERING REPORT PACIFIC SOILS ENGINEERING, INC. Clients Representative: . 1 Tract No.: Date: b/a3 ! q7 Project Location: sijFlp Weather Conditions: .s ir >L_lcr Client: Project Name: Day: Contractor: Approximate Fill Yardage : > Type and Number of Rigs in Operation: k;r F3 Work Order: & wtr~ - bL i Description of Project Activities: Site Visitors / Firm: . L Page -of - dafldrpt.sam For Pacific Soils Engineering, Inc. Received bv: