Loading...
HomeMy WebLinkAbout1222 ESMAT WAY; ; CB153979; PermitCity of Carlsbad • 1635 Faraday Av Carlsbad, CA 92008 01-08-2016 Residential Permit Permit No: CB153979 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: 1222 ESMAT WY CBAD RESDNTL Sub Type: SFD Lot#: 1 Constuction Type: 58 Reference#: MS 11-02 Structure Type: SFD Bathrooms: 5.5 Status: ISSUED Applied: 11/17/2015 Entered By: SLE Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 1563512000 $610,295.00 1 5 Orig PC#: PC150036 Plan Approved: 01/08/2016 Issued: 01/08/2016 Inspect Area: Plan Check#: PC150062 Project Title: LANAI: PHASE 1 I PLAN 5 3,842 SF LIVING/ 697 SF GARAGE/ 493 SF PATIO/ 148 SF DECK Applicant: SHEA HOMES 9990 MESA RIM RD SAN DIEGO CA 92121 858-526-6500 Building Permit Add'I Building Permit Fee Plan Check Add'I Plan Check Fee Plan Check Discount Strong Motion Fee Park in Lieu Fee Park Fee LFM Fee Bridge Fee Other Bridge Fee BTD #2 Fee BTD#3 Fee Renewal Fee Add'I Renewal Fee Other Building Fee HMP Fee Pot. Water Con. Fee Meter Size Add'I Pot. Water Con. Fee Reel. Water Con. Fee Green Bldg Stands (SB1473) Fee Green Bldg Stands Plan Chk Fee $2,370.26 $0.00 $1,659.18 ($500.00) $0.00 $79.34 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $5,609.00 FS3/4 $0.00 $0.00 $25.00 $0.00 Owner: Meter Size Add'I Reel. Water Con. Fee Meter Fee SDCWAFee CFD Payoff Fee PFF (3105540) PFF (4305540) License Tax (3104193) License Tax (4304193) Traffic Impact Fee (3105541) Traffic Impact Fee (4305541) Sidewalk Fee PLUMBING TOTAL ELECTRICAL TOTAL MECHANICAL TOTAL Housing Impact Fee Housing lnLieu Fee Housing Credit Fee Master Drainage Fee Sewer Fee Additional Fees Fire Sprinkler Fees TOTAL PERMIT FEES Total Fees: $40,484.24 Total Payments to Date: $40,484.24 Balance Due: Inspector: f1,t. ~S'. FINAL APPROVAL Date oS/t:>6/16 Clearance: FS3/4 $0.00 $356.00 $0.00 $0.00 $11,107.37 $10,252.96 $0.00 $0.00 $3,160.00 $0.00 $0.00 $326.00 $89.00 $106.13 $0.00 $0.00 $0.00 $0.00 $881.00 $4,963.00 $0.00 $40,484.24 $0.00 NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions." You have 90 days from the date this pennit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or seNice fees in connection with this project. NOR DOES IT APPLY to any City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 01-08-2016 Storm Water Pollution Prevention Plan (SWPPP) Permit Permit No:SW150446 Job Address: Permit Type: Parcel No: Reference #: CB#: Project Title: Applicant: SHEA HOMES 1222 ESMAT WY CBAD SWPPP 1563512000 CB153979 LANAI: PHASE 1 I PLAN 5 9990 MESA RIM RD SAN DIEGO CA 92121 858-526-6500 Emergency Contact: xx xx SWPPP Plan Check SWPPP Inspections Additional Fees TOTAL PERMIT FEES Lot#: Owner: Total Fees: $282.00 Total Payments To Date: Status: Applied: Entered By: Issued: Inspect Area: Tier: Priority: ISSUED 11/17/2015 SLE 01/08/2016 1 M $54.00 $228.00 $0.00 $282.00 $282.00 Balance Due: $0.00 FINAL APPROVAL DATEo~fo~ftb CLEARANCE. ___ _ SIGNATUREfv:l· ~~ Inspection List Pennit#: CB153979 Type: RESDNTL SFD Date lnspectio_n _ _l!_em Inspector 09/06/2016 19 Final Structural 09/06/2016 89 Final Combo MC 08126/2016 89 Final Combo PD 08126/2016 89 Final Combo 06/0612016 33 Service Change/Upgrade PD 04114/2016 23 GasfT esVRepairs MC 04113/2016 17 Interior Lath/Drywall MC 04/13/2016 18 Exterior Lath/Drywall MC 04/13/2016 23 GasfTesVRepairs MC 04/11/2016 16 Insulation MC 0410712016 27 Shower Pan/Roman Tubs MC 04/07/2016 84 Rough Combo MC 03129/2016 13 Shear Panels/HD's MC 03121/2016 22 SewerNvater Service MC 03115/2016 15 Roof/Reroof MC 0210112016 11 Ftg/Foundation/Piers MC 02/0112016 31 Underground/Conduit-Wlrin MC 01122/2016 21 Underground/Under Floor MC Wednesday, September 07, 2016 Act RI Fl co RI AP AP AP AP co AP AP AP AP AP AP AP AP AP LANAI: PHASE 1 I PLAN 5 3,842 SF LIVING/ 697 SF GARAGE I 493 S Comments COF LEAK WALLS ONLY, NEED CEILING CERT. BUILDING WASTE TO SEWER P.0.C, WATER TO METER. UFER. WASTE ONLY TO BLDG. LINE, NEED P.0.C. Page 1 of 1 Building Division INSPECTION RECORD 'NSPECTION RECORD CARD WITH APPROVED ',vPLANS MUST BE KEPT ON THE JOB CB153979 1222 ESMAT WY LANAI: PHASE 1 / PLAN 5 3,842 SF LIVING/ 697 SF GARAGE/ 493 SF PATIO/ 148 SF DECK RESDNTL Lot#: 1 SFD SHEA HOMES 621 CALL BEFORE 3:30 pm FOR NEXT WORK DAY INSPECTION 621 FOR BUILDING INSPECTION CALL: 760-602-2725 l 0 ~ ·~ECORD COPY OR GO TO: www,Carlsbadse gov/Building AND CUCK ON "Request Inspection· DATE: I 8' /I • IF ·YFS" IS CHf':ci-.;co BELOW rH/\T DIVl'::.ION·s APPROVAL 15 REQUIRED PRIOR TO REqt1F5_TING J\ FJNAL BUILDING INSPECTION. IF YOU fl,\VC ,\NY QUESTIONS PLEASE CALI THE APPL.IC/\BLE DIVISIONS AT THE PHONE NUMBERS PROVIDED BEL.OW. AFTER ALL RE:QUIREn Al-'PROVALS /-\h'.l,: SIGNED OFr-F/1.X TO /60-602-3560. EMAIL TO BL!JGINSPECTJ()NS cc,\RLS8ApC,\.GOV OR BRING IN·\ COPY OF THI':.'; C,\J,'O To· 1635 F~'\F?/\01\Y AVE. C .• \RLSl::1/\D, CA. 92008. BUILDING INSPECTORS C/1,N BE RE.ACHFD AT 7GO-GQ?-2700 BET'NEEN 7:30 AM -8:00 i\M 'THE D,\Y OF YOUR INSPECTION. Required Prior to Requesting Building Final If Checked YES Planning/Landscape CM&( (Engineering Inspections) Fire Prevention #12 REINFORCED SIEEL #66 MASONRY PRE GROUT OGROUT D WALL DRAINS -~.v!O TILTPANEIS #11 POUR STRIPS #11 COLUMN FOOTINGS #14 SUBFRAME D FLOOR D CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANEIS #16 INSUIATION #18 EXTERIOR IATH #17 INTERIOR IATH & DRYWALL #51 POOLEXCA/SIEEf./BONO/FENCE PREPI.ASlB!/RNAL #28 SOLAR WATER #29 RNAL #600 PRE-CONSTRUCTION MEETING #603 FOLLOW UP INSPECTION :OS NOTICETOCLEAN · •'lf607 WRITTEN WARNING #609 NOTICEOFVIOIATION #610 VERBAL WARNING REV 10/2012 7 6().944-8463 7604311-3891 760-602-4660 Allow 48 hOurs cau before 2 pm Allow 48 hours #41 UNDERGROUND DUCTS & PIPING #44 D DUCT & PLEIIUM O REF. Pf PIN& #43 HEAT·AIR COND. SYSIEMS #49 RNAL Cam, -COMBO INSPECTION #81 UNDERGROUND (11,12,21,31) #82 DRYWALL,EXTIATH, GASTES(17,18,23) #83 ROOF SH EATING, EXT SHEAR (13,15) #84 FRAME ROUGH COMBO (14,24,34,44) Q #85 T-Bar(14,24,34,44) #89 ANAL OCCUPANCY (19,29,39,49) A/S UNOERGROUNDVISUAL A/SUNDERGROUNDHYDRO A/S UNDERGROUND FLUSH A/5 OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/SRNAL F/AROUGH·IN F/ARNAL FIXED EXTINGUISHING SYSTEM ROUGH·IN FIXED EXTING SYS1EM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURE TEST MEDICAL GAS RNAL Date Ins ector SEE BACK FOR SPECIAL NOTES ot- Ccityof Carlsbad CIRCUIT CARD B-36 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AVAILABLE ATTHESERVICEEf tnPMENT FOR THE ROUGH INSPECTION Address: J1. 1.~ ~ ... -.L I I • Pem1it Number: I [;5C, 7<; <;t_ . , . -i,l;one: ( '-1'1. \ ~'13 · 7812. Owner: Area In Sq. Ft. 3, B</2-Contractor: Phone: PANEL:r -• -r 7.,V:. A.LC. VOLTS fl) WIRE LOCATION CKT BKR WIRE MISC REC REC LTG MISC WIRE BKR CKT LOCATION SIZE SIZE TYPE SIZE TYPE SIZE J'.·M.J 1 to J"L Cl4 I y. 2 DV/,¥1 3 ...... 10 (,I,! \ 4 A 1c.. 5 Jo to I 6 Sv.l? 7 Ion 'I• Ci.l t 8 DvV 9 . 1, 1\.f l'vo \ 10 ,_n 11 15 14 c ... 12 (,-,.~nr•t, 13 1r IY c .. A I 14 Ki~ ?Al 15 1.o ri Ci-. Li 16 1-\ ,c.,V' r1 17 '2,D I" C.IA I 18 v+ c,-i::1 19 -z_o t 1.. r" 't 20 Hnrvl 21 1.,o 11,. N, l 22 b.lr 23 ~ IC (u l 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 ! 40 41 42 MAIN: IS Z'l.'i. AMP BRK/FUSE O MLO Computed Load AMPS BUS: AMP See Calculation Worksheet on back Service entrance or feeder conductors: Branch circuits required: A)Slze: No. B)Type: D CU DAL A) Lighting Circuits 220 -3(b), 4(d) B) Two Small Appliance Circuits 210-11(e) C) Insulation: D) Conduit Size: ___ C) Laundry Circuit 220-16(b) Service ~round/bond4 [Jku DAL D) Central Heating Equipment 422-12 A) Size: No. B) Type: E) Bathroom 210 -52(d) Jil Clamp locatlon(s): UFER 250-50(c) Remarks: D Water Pipe 250-104 D Ground Rod 250-52 D GFCI locations 210 -8, 680-70: ~Kitchen I cerlify that all terminations have been torqued In accordance with manufacturer's 0 Bathroom(s) instructions and that the work shown on this circuit card represents the full extent of li!I Garage(s) DH(dromassage Tub the work performed under this permit. 15 Outdoors Iii """""r :j &-Downer AFCI Protected Clrc. 210-12 D Contractor ' 00-Bedroom(s)/ '-i"i"j s~ D Signed I Date --1-1 ,,,,, 7T I B-36 Page 1 of2 Rev. 03/09 Ccityof Carlsbad CIRCUIT CARD B-36 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov THIS CARD MUST BE FILLED OUT AND AV AJLABLE AT THE SERVICE Bf UIPMENT FOR THE ROUGH INSPECTION Address: J 1. z. 7 c;_ f ..I 1 _ -Permit Number. IS-3'?7<:; . owner: (' I " • Pt-.6ne:(, I c.j\ R'f 3-Jl'i{2. 7 :{801 ~ Area in Sq. Ft. Contractor: Phone: PANEL,:Cu 0 , ri< A.LC. VOLTS , 0 WIRE LOCATION CKT BKR WIRE MISC REC LTG MISC WIRE BKR CKT LOCATION SIZE SIZE TYPE REC SIZE TYPE SIZE L"'f'I' 1 IS' I' r,, s /o 2 i:;,~~ 3 I'> , I, .,, 4 ' 1Shl 'j,. 5 ,r I ,_ <i 6 ~tr\J 7 ., .:) I tJ 8 f }."I I' 9. ) I l 10 f Al.I 'l. 11 '> , .. I 12 -e ... H, f-Li 13 '2D 1"2-1 14 \fJ~ 15 Z.o rz. I 16 91 "'~ 17 'w 1'2-5 18 r---~ 19 I< 11.f fi ~ 20 r1-'1Sot1 21 I'S' '" /4 9 22 ~+ lits 23 It; I'' ' Ir ..'.> 10 24 1>1rl 4 J.W 25 l S' ,~ '5 'f 26 . 27 28 29 30 31 32 33 34 35 36 37 38 39 I 40 41 . 42 MAIN:0 IUO AMP BRK/FUSE O MLO Computed Load AMPS BUS: AMP See Calculation Worksheet on back Service entrance or feeder conductors: Branch circuits required: A) Size: No. I B) Type: 0 CU 151! AL A) Lighting Circuits 220 -3(b), 4(d) B) Two Small Appliance Circuits 210-11(e) C) Insulation: D) Conduit Size: ___ C) Laundry Circuit 220-16(b) Service ground/bond: D) Central Heating Equipment 422-12 A) Size: No. B) Type: D CU DAL E) Bathroom 210 -52(d) ~lamp location(s): FER 250-SO(c) Remarks: D Water Pipe 250-104 D Ground Rod 250-52 D GFWa:tions 210 -8, 680-70: Bathroom(s) )!![ Kitchen I csrtify that all tennlnations have bean torqued in accordance wtth manufacturer's instructions and that the work shown on this circuit card ·represents the full extent of )fJ Garage(s) OHydroma~e T~ the work performed under th;s permit. & Outdoors ~ Ltw 1 D Owner AF~tected Gire. 210-12 D Contractor '"llt"r "'f""' ... I..C..I, edroom(s) l,ivituj Sf""U.S D Signed Date .,,..,... It ' B-36 Page 1 of 2 Rev. 03/09 ' JAAM Electric RESIDENTIAL -COMMERCIAL -TENANT IMPROVEMENT LOAD CALCULATIONS Lanai Plan 5 3842 SQUARE FOOTAGE x 3 WATTS 11526 watts 2 APPLIANCE CIRCUITS 3000 watts 1 LAUNDRY CIRCUIT 1500 watts 1 GARBAGE DISPOSAL 828 watts 1 MICROWAVE 1500 watts 1 DISHWASHER 1200 watts 2 FAU 1800 watts 1 OVEN 8000 watts SUBTOTAL 29354 watts - 1st 10000 watts@ 100% 10000 watts BALANCE @ 40% 7742 watts NC#1 @125% 8880 watts NC#2 5280 watts TOTAL WAITS 31902 watts·· 31902 WATTS-240 VOL TS 133 amps USE 200A MINIMUM 697 Greenfield Dr. El Cajon, CA 92021 -(619)579-6500 -FAX (619)579-3733 CALIFORNIA CONTRACTORS LICENSE NUMBER 1010289 City of Carlsbad Permit No: CB153979 -Plan 5 Address 1222 Esma! Way Type of Work SFD and Duplexes Residential Additions Remodels I Lofts Apartments & Multi-family Ga rages/Sun rooms/So la ri u ms Patio/Porch Enclosed Patio Decks/Balconies/Stairs Retaining Walls, concrete,masonry Pools/Spas-Gunite Tl/Stores, Offices Tl/Medical, restaurant, H occupancies Photovoltaic Systems/# of panels Fire Sprinkler System Air Conditioning -commercial Air Conditioning -residential Fireplace/ concrete, masonry Fireplace/ prefabricated Metal Valuation: Comm/Res (CIR): Building Fee Plan Check Fee Strong Motion Fee Green Bldg. Stand. Fee Green Bldg PC Fee License Tax/PFF License Tax/PFF (in CFO) CFO 1st hour of Plan Check Fire Expedite Plumbing Mechanical Electrical Valuation Worksheet Assessor Parcel No. Date 12/03/2015 Area of Work Multiplier 3,842 $139.52 $166.81 $45.78 $124.35 657 $36.40 493 $1213 $19.71 148 $19.71 $24.26 $51.56 $45.78 $63.70 $400.00 $0.00 $0.00 $0.00 $0.00 4,499 $3.94 $6.37 3,842 $5.31 $4,883.11 1 $3,319.61 TOTAL $610,295 CFO By SLE VALUE $536,035.84 $0.00 $0.00 $0.00 $23,914.80 $5,980.09 $0.00 $2,917.08 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $0.00 $17,726.06 $0.00 $20,401.02 $0.00 $3,319.61 $0.00 $0.00 $610,294.50 Building Division C 0 Yes (PFF=l.82%) 0 No (PFF = 3.5%) $2,370.26 Land Use: $1,659.18 Density: $128.00 Improve. Area: $24.00 Fiscal Vear: $150.00 Annex. Year: Factor: $21,360.31 $11,107.36 CREDITS PFF and/or CFD Explanation: TBO TBO TBO b~A,lnc land planning, civi l engineering, surveying January 27, 2016 w.o. 452-1214-600 Mr. Michael Collins CITY OF CARLSBAD Building Inspection 1635 Faraday Avenue Carlsbad, CA 92008 ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Engineer RE: B ILDING FORM VERIFICATION FOR 1222/1226/1230 ESMAT WAY (PARCELS , , & 3, PARCEL MAP 21225) MS 11-02 Dear Mr. Collins: This letter is to attest that BHA, Inc. has staked the location for the house construction on the above-mentioned lots. We have checked the locations of the building forms of the proposed houses and found the horizontal and vertical location to conform to the Site Plan. If you have any questions regarding this matter, please contact our office. Sincerely, b~A, Inc. <iLl~ Ronald L. Holloway Senior Vice President R.C.E. 29271 RLH:pjh cc: Jason Korszeniewski -Shea Homes building form verification.ltr 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780 Southwest Inspection and Testing, Inc. 441 Commercial Way, La Habra, Ca 90631 (562) 941-2990 • (714) 526-8441 • Fax (562) 946-0026 REGISTERED IN~PECTOR'S DAILY REPORT I SWIT Job No. I D~ ~ I \°~JI r-?~ /'& fr, TYPE OF !'.1.7Reinforced Concrete D Welding D DINEpoxy INSPECTION Post Tensioned Concrete D Fireproofing D Wood Framing REQUIRED D Reinforced Masonry D Asphalt D Other Job Addr~ }U£V+ ( J~. Tract No. Lot No. -Job ~men ~ Cc..1 ~ // Perrz1r-f-u~ Issued B.f '--,~ Typ~ W,ru£ture ~ f 'l, I ._.,.. -Arc'Jjef f i~ ij;~_, Ma~>D,e\°F!BJi~J!~e,~~.',1~o/' ~~ ~;; .:!f: I Engi~L, U "'vi,c r Ct. (_ ---. l · ... ~h .. u~·1-,,,'"1J~ / / ~Jt!OJ,.;t ~/~~- lnspjf<J's N~-, Cu-""e' Su~t~~/.re~/SttKCe,~~, '' -<-- TESTS PERFORMED SAMPLE AIR CONC WATER TIME SET# TRUCK# TICKET# LOCATION SLUMP TEMP TEMP ADDED CAST MIX# REMARKS - , INSPECTION SUMMARY-LOCATIONS OF WORK INSPECTED, TEST SAMPLES TAKEN, WORK REJECTED, JOB t->ROBLEMS, PROGRESS, REMARKS, ETC. INCLUDES INFORMATION ABOUT -AMOUNTS OF MATERIAL PLACED OR WORK PERFORMED, NUMBER, TYPE & IDENT. NO'S OF TEST SAMPLES TAKEN: STRUCT. CONNECTIONS (WELD MADE H.T. BOLTS "[()RQUED\ CHECKED, EJC. , f~h/ / ~--/~ ·• /14~ft:,L/ ~ /;-/ ~ ~/r;~~ C.· 5'f'~ ,<... -~~. , ~/.-4-./1--? 4~ (" : . /v-f-V ~'--4.LI/ ~d <;/f , I' -~ l .. 1..., ,1 L/C-/7 z (_ 1<:( s ;-1-,s;;--'l' J -c--< ......... .. -II c:._r-Y-.Ar.t/_;,,J ., '/,, )~ / . CERTIFICATION OF COMPLIANCE I HEREBY CERTIFY THAT I HAVE OBSERVED TO THE BEST OF MY KNOWLEDGE ALL OF THE ABOVE REPORTED WORK UNLESS OTHERWISE NOTED. I HAVE FOUND THIS WORK TO COMPLY WITH THE APPROVED PLANS, SPECIFICATION, AND APl)'1CABLE SECTIO THE GOVERNING BUILDING LAWS. / -v -,;;:_ -~ t.,_ SIGNATURE OF REGISTERED l~S ECTOR -r-?, I -.~ / I ,;--{ t.ev--/ \ . ..,. I ~ tl'f" SPECIAL TY NO. AGENCY (/ A ,. ;,;L~~4 + ? ~-G(.Jt- / <::; ""( 9 -=kl ( ~/#J.bt-< I 7c; /V::Iji .1/;,-~ r' ( I, ( 7 1 ......,. i I J ,. - 7 l CONTINUED ON NEXT PAGE 0 PAGE ' OF TIME IN4 TIME OUT SAMPLES // Approved By Project Superintendent White -Office Copy • Canary-Accounting Copy • Pink -Inspector's Copy • Goldenrod -Jobsite Copy ,m F-049 ©Southwest Inspection & Testing, Inc. w.o ......... ~-k .......... ~~t~·--'--.-· ...... _. __ _ DATE.~~;~,~'l=·'l~u,:=;....... ____ _ NAME. __ '~£~~---------- HOURS _____ ~------------ Geotechnical • Coastal • Geologic • Environmental FOOTING TRENCH OBSERVATION SUMMARY Client Name: --~'r..:...::;;,:;,J::.._ ____________ Project Name: ---=-":;..:1...:alt_._/Ao..:..&.../ __________ _ Location/Tract: J 7 ... .<JI / /.1 .. !J".. # 11 ,· ,7 /!"-,....._.......;.,._;.;.;.;.~"'""'""""' Unit/Phase/Lot(s): h.~ 'l"L -H-: /,T /1 I--~" t::.-.-, /', ·LH'r,,, I . .,{ Observation Summary ~ Initials .. h ,~& Date ' I L%:' Initials 11/!(e Date ; I --- Initials Date /Initials ---__ ..___ Date I A representative of GeoSoils, Inc. observed onsite soil and footing trench conditions. Soil conditions in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and are in general conformance with those indicated in the geotechnical report. A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing excavations generally extend to proper depth and bearing strata, and are in general conformance with recommendations of Jhe geotechnical report. A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The setback was in general accordance with the recommendations of the geotechnical report. / / I I Notes to Superintendent/Foreman 1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete. 2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnical report for presoaking recommendations. We note that clayey soils may take an extended period of time for such, and the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e., heavy rain, etc.), we should be contacted to perform additional site observations and/or testing. 4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's design, if different from the geotechnical report. Notes to Building Inspector Soil compaction test results, as well as depth of fill , relative compaction, bearing values, corrosivity, and soil expansion index test results are contained in the As-Graded Geotechnical or Final Compaction Report provided at the completion of grading. 57 41 Palmer Way Carlsbad, CA 92008 (760) 438-3155 1446 E. Chestnut Ave. Santa Ana, CA 92701 (714) 647-0277 Representative of GeoSoils,· Inc. 26590 Madison Ave. Murrieta, CA 92562 (951) 677-9651