Loading...
HomeMy WebLinkAbout1251 BASSWOOD AVE; ; CB070610; Permit03-20-2007 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Electrical Permit Permit No CB070610 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Reference # Project Title 1251 BASSWOOD AV CBAD ELEC 2051122600 Lot# ORTH RES- ROOF MOUNTED PV Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 03/05/2007 LSM 03/20/2007 03/20/2007 Applicant CLEAN POWER SYSTEMS INC STE 205 9948 HIBERT ST SAN DIEGO 92131 Owner ORTH GREGORY FAMILY TRUST 04-26-05 1251 BASSWOOD AVEI CARLSBAD CA 92008 Electric Issue Fee Single Phase per AMP Three Phase per AMP Three Phase 480 Per AMP Remodel/Alteration per AMP Remodel Fee Temporary Service Fee Test Meter Fee Other Electrical Fees Additional Fees 0 0 0 0 $1000 $000 $000 $000 $000 $000 $000 $000 $11000 $000 TOTAL PERMIT FEES $12000 Total Fees $120 00 Total Payments To Date $12000 Balance Due $000 BUILDING PLANS IN STORAGE ATTACHED Inspector FINAL Date /PRO^AL Clearance NOTICE Please take NOTTCE thaf'approval of your project includes the "Imposition" offees, dedications reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside void or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of Imitations has previously otherwise expired PERMIT APPLICATION CITY OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave , Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO (L&O7 EST VAL Plan Ck Deposit Validated By Date Address (include Bldg/Suite #)Business Name (at this address) Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units Assessor's Parcel #Existing Use Proposed Use escription of Work >o£ -yv CONTACi PERSON (itrtifferent from applicant) SQ FT #of Stories # of Bedrooms # of Bathrooms Name Address ) City 3 APPLICANTS^ Q Contractor D'Agent for Contractor D Owner [3 Agent for Owner gve*iw C State/Zip Telephone # Fax #..... r Name Add'ess City State/Zip Telephone # Add.'ess City State/Zip Telephone # (Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code] or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$50011 Name State License # — ^ I VJ \ 5tfl Designer Name " State License # Address License Class C^, \ O Address ' Deny State/Zip City Business License *_>{ r? 12 City State/Zip Telephone tt •*•»-«» ^v\YI? B -13*73. Telephone 6 WORKERS'COMPENSATION ;;, " ' ..,iffi4:::' ' ::...1?:."V' -,.,.!:,;,•:-,• . ,.:tfA, '• Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations n I have and will maintain a certificate of consent to self insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My worker's compensation insurance carrier and pqhcy number are ir ja,,^_,^._ _ ^"Expiration Date L? " I ~ 0 /Insurance Company Policy No (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$100] OR LESS) n CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California WARNING Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars ($100,OJlOte"ln additiontf&the cost of compensation, damages as provided for in Section 3706 of the Labor code /interest and attorney's fees SIGNATURE •^^^z^^^\/ £<^-^£ -- __ DATE "^f/S'/O ~7 7 OWNlRgUjl^RDECLARifnON : i , ,-, ' T I hereby affirm That I am exempt from the Contractor's License Law for the following reason l~l I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale) l~l I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) l~l I am exempt under Section _ Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement l~l YES QNO 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone number / contractors license number) ___ 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type of work) _ _ _ _ _ _ PROPERTY OWNER SIGNATURE DATE COMPLETE THIS SECTION FOR /VO/V-fl£SW5£W7Mi BUILDING PERMITS ONLY sIB ** 7 x Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? d YES d NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? [~| YES O NO Is the facility to be constructed within 1 ,000 feet ol the outer boundary of a school site? O YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code) LENDER'S NAME __ LENDER'S ADDRESS I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes I ALSO AGRI.E TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 1 80 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced Jg^er period of 1£JJ days (^ect;on^}06 4 4 Uniform Building Codei 'PLICANT'S SIGNATURE DATE rHITE File YELLOW Applicant PINK Finance Inspection List Permit# CB070610 Type ELEC ORTH RES-ROOF MOUNTED PV Date Inspection Item Jnspector Act Comments 10/17/200839 Final Electrical PY Fl OK TO FINAL 04/05/2007 34 Rough Electric PY NR Friday, October 17, 2008 Page 1 of 1 EsGil Corporation In (Partnership -with government for <BuiCding Safety DATE March 16, 2OO7 J3-APPUCANT UBIS^ JURISDICTION Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 07-61O SET I PROJECT ADDRESS 1251 Basswood Avenue PROJECT NAME Orth Solar Photovoltaic IXJ The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes I | The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff I | The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to "... XI Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Eric Jensen Enclosures Esgil Corporation D GA D MB D EJ ID PC 3/8 trnsmtldot 9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 f~ DATE (ttrj!/DD/YYn) 05/15/2006 PRODUCER AD Insurance Service*! FO Box 3646 Omaha, HE 68103-0646 (877)236-4420 INSUREDClean Power Systems, Inc. aba Clean Power Systems 9948 Hibert St Ste 205 San Diego, C& 92131-.L034 _L CTI. 1273 323163 THIS CERTIFICATE IS ISSUED AS A MATTER OF INFORMATION ONLY AND CONFERS MO RIGHTS UPON THE CERTIFICATE HOLDER THIS CERTIFICArE DOES NOT AMEND, EXTEND Ofl ALTER THE COVERAGE AFFORDED BY THE POLICIES BELOW INSURERS AFFORPiNG COVERAGE INSURER A- California Insurance Company INSURER B INSURER C INSURER D INSURER E NAK: COVERAGES THE POUCIES OF INSURANCE LISTED BELOW HAVE BEEN ISSUED TO THE INSURED NAMED ABOVE FOR THE POLICY PERIOD INDICATED NOTWITHSTANDING ANY REQUIREMENT. TERM OR CONDITION OF ANY CONTRACT OR OTHER DOCUMENT WITH RESPECT TO WHICH THIS CERTIFICATE MAY BE ISSUED OR MAY PERTAIN, THE INSURANCE AFFORDED BY THE POUCIES DESCRIBED HEREIN IS SUBJECT TO ALL THE TERMS EXCLUSIONS AND CONDITIONS OF SUCH POLICIES AGGREGATE LIMITS SHOWN MAY HAVE BEEN REDUCED BY PAID CLAIMS OSKI.TR & amiSNSRD TYPE OF INSURANCE GENERAL LWBttJTY COJ8MERCIAL GENERAL LIABILITY _j CLAIMS MADE | | OCCUR GEN1 AGGREGATE LIMIT APPLIES PER 1 POUCY 1 IJECT | JLOC AUTOMOBILE LIABILITY — - - GAF ANY AUTO ALL OWNED AUTOS SCHEDULED AUTOS HIMkD AUTOS NON-OWNED AUTOS ASE LIABILITY ANY AUTO EXCESSflJMSRELLA LIABILITY | OCCUR | ] CLAIMS WADE DEDUCTIBLE RETENTION S WORKERS COMPENSATION AND EMPLOYERS LIABILITY ANY PROPniETOR/PARTNER/EXECUTiVE OFFICER/MEMBER EXCLUDED? If yes. bescrtne under SPECIAL PROVISIONS below OTHER POUCY NUUSER 46-006727-01-02 POLICY EFFKTWfDATE MNUDO/m 06/01/06 POLICY EXPIRATION DATE ftMMfflrYYI 06/01/07 UHOTS EACH OCCURRENCE DAMAGE 1O RENTED PREMISES (Ea occurasnco) l.iED 6XP (Any one parson) PERSONAL & ADV INJURY GENERAL AGGREGATE PRODUCTS COMP/OPAGG COMBINED SINGLE LIM11 (Es accident) BODILY INJURY [Pot peiion) BODILY INJURY (Per Bcodcfli) PROPERTY DAMAGE(Pet accident) AU1OOMLY EA ACCIDENT OTHER THAN AUTO ONLY EAftCG AGC EACH OCCURRENCE AGGREGATE ... __ Si | VW STATU-' pWJ E-L EACH ACCIDENT EJ- DISEASE EA EMPLOYEE EJ_ DISEASE POUCY LIMIT S $ $ S i1 s i s £ s s $ 6 S ^ S s 5 S ! ci,o~bo,doo~ | .1,000, 000a s i, ooo, ooo DESCRIPTION OP OPERATIONS / LOCATIONS / VEHICLES / EXCLUSIONS ADDED BY ENDORSEMENT / SPECIAL PROVISIONS CERTIFICATE HOLDER CANCELLATION Clean Power Systems 9948 Bibert St Ste 205 San Diego, CA 92131-1034 Attns .Project Manager SHOULD ANY OF THE ABOVE DESCRIBED POLICIES BE CANCELLED BEFORE THE EXPIRATION DATE THEREOF, THE ISSUING INSURER WILL ENDEAVOR TO MAIL 30 DAYS WRITTEN NOTICE TO THE CERTIFICATE HOLDER NAMED TO THE LEFT, BUT FAILURE TO ISO SO SHALL IMPOSE NO OBLIGATION OR LIABILITY OF ANY KIND L'PON THE INSURER ITS AGENTS OR REPRESENTATIVES. AUTHORIZED REPRESENTATIVE .f .#.£_ *i~ OD78336 ACORO 25 (2001W8) © ACORD CORPORATION 1988 PLANNING/ENGINEERING APPROVALS PERMIT NUMBER C.13 Q^7 -U, I Q DATE ADDRESS 'SIS I RESIDENTIAL TENANT IMPROVEMENT RESIDENTIAL ADDITION MINOR PLAZA CAMINO REAL (<$10,000.00) CARLSBAD COMPANY STORES POOL / SPA VILLAGE FAIRE RETAINING WALL COMPLETE OFFICE BUILDING OTHER 5V>(ar gieclrrc. PLANNER DATE 3-~7-Cn ENGINEER DATE SYSTEMS Solar Electric Solution Permit Package Greg Orth Mailing Address 1251 Basswood Ave Carlsbad, CA 92008 Installation Address 1251 Basswood Ave Carlsbad, CA 92008 APPROVED ^rsL^ MAR 2 Q2007 City of CARLSBAD BUILDING DEPT Phone Number Cell Number Fax Numer Email 760 729 2284 760 685 5028 0 gorth@roadrunner com System Designed and Installed by: Clean Power Systems, Inc 13230 Evening Creek Dr South Suite 203 San Diego, Ca 92128 Lie #C10-827138 (858) 748-3636 While reviewing the contents of this package, if you have any questions please contact our permitting department at 858-748-3636 SYSTEMS Table of Contents Page I Solar Electric Solution Permit Package Cover Sheet Page 2 Table of Contents Page 3 Plaques & Signage Page 4 Site Plan / Roof Layout Page 5 Single Line Diagram Page 6-7 Solar Panel Spec Sheet Page 8-9 Stnng Sizing Chart Page 10-11 Inverter Spec Sheet Page 12 Rack Engineering Certification Page 13 Mounting Hardware Attachment Detail Page 14 Racking Detail Page 15 Racking Detail Page 16 Roof load calculations Page 17 Roof framing details Page 18-19 SMA Combi-Switch Cut Sheet ; 'F7 il/P""3 j£ S Y S-T E M S Plaques All plaques shall be installed as required by utility and NEC Examples of our plaques are PV SYSTEM DISCONNECT FOFq At alternate power source AC Disconnect UTILITY OPERATION |DC DISCONNECT J At DC Dicsonnects [DC JUNCTION BOX | At DC Junction Boxes WARNING THIS SERVICE SUPPLIED BY ALTERNATE POWER SOURCE(S) WITH DISCONNECT(S) LOCATED AS SHOWN At utility meter (will include map locating solar and disconnect) Basswood Ave. 03 O 2 > oo oo ;f ^JcrQS *i ^§ ™ gnffl "" o nO RF — oa= o "*) l~~l C^ c/')J h ^ ^ >__iJ t ^^ 1 — s 1 j^ <~r\ <D 2., T1 »—i—i ^"s • 'a W O t"1 i, p a m•^ co » 1 ^5 taHBlJ^^H ^ J^ O '^/'i n ° 3^ O • "•J [J ^ <! ^O « J^tD r" ~^_~ ? Y^ 2 Hpl ^>. • • ! ° - U I) 63 Oijs I W rt iff ? : S o O Qrf £ O£• c B. B. 1 1 ' -T^r"L--^> S O it it-o h~^ 3 t^> hoF^S r^ TO P jC r/13 JiT fo 2 HC tn i£j ^ Q. cn *2. to 3 ^^^ ^ & ^ * i^m ° 3 § 3 reS H o < § <r2 d b- <? § asH tf § 3 CL=; ^5 — .T3 SS. » o g 200 ^ 3 ^ S (5 at S — g S H ia. H 3 ^a i » 2u 2Cu C 1 G3 Cu \ \ ? 3 ln OJ P^ at 0 H 3Q. H TO 0c3Q.or structure 10 me ursi reaunyaccessible disconnectingmeansThe disconnect means shall corn piwith 690 14(A) through 690 14(D)n n -^+"J + -i ^~-• -i • -i -i i -i — i1 n ' n_i_ j + j1 -i • -i.( i -| — i 1 n ' n_i i -\ — i 1 n ' n_i_ j _)_ j1 n ' i + J + J1 -i ' . -\ + J + Ji i ^^sV 1 1 ^ 1 1 1 \ ^ 1 U'> 11 ^^^. T^ 1 G ur output circuits 01 autility-interactive inverterfrom building-integratedor other photovoltaic systemare run inside a buildingor structure, they shallbe contained in metalicraceways or enclosuresfrom the point of penetrationof the surface of the buildingKJ — 1 -2J 2 *"3 C/3 en JQ O i>-+} tO — ® <s> \^n £J*-! O o ^en ^-goo. C/l ISg W ""* i> Os ~j rS n • — :o ° V <">o 2 -^1 3 ?r~-J 65 — D oo re0 T3 oo 1 i 1<T> i_ i~ 3 3C < 3 f~^•J CD n OJo K> g 1 vP J y| <T> 1 U) 5! "~~-T3<. bOOq to P 3 O ,>• 0. > CO S, A 2 g-S \ "^ SN O S g. > / £1_^x w sr CDH-t C/!5a n^} to ^ 1-5 CD Per NEC 690 31 (E)Where direct currentPhotovoltaics source„ ± __^. __ ^ ir3to n rn> O m 73 7T C/3 ^J (JO o I ii 3 OJ o o °^^K) O Woo £/) fill SQ» O — • CD Sj Zi^ £L = m00 f° D oo C/3c K)O c/5 St- a CO 00*.UJ I^O^..^ K> 3 "— 'a PZ ^ "V-4 ^> CD 2,r ^CfQ rs^ ,_. ^ y» DO O ^ 3- P3 3. W"** CO CL t/5 M 1 — <^ ^ 5"fc* o ^J> O ^Co S wvi °* L-i> 2^ <! ^x^ o 5i^1^ 2 "n ^• * *!* irl ^ ^* A 5§«° 3ft e 'In2§« *go B ov= i 3IS? if 8 o '1 1 =, Q. 1 llM r-T>1 \^ 1 3 g ** R-S w«^>3 a H f-1 (JQ C 2C C/55 ^ e g a:mw M 5. ™ z; K> -P^ ^^ ^— sT /*\ -n t^5 §?3fS — i O < c f"^nl x 8 § sHi 2 3 CL^ Z cr'g S c7 o § 5oj K) § X ro 3 ^g o. 5T ^ o" * « 1 § o H 5 Q. -1 3 "°= -c s^ ac z1 2! ^N•^ O5B 3 Q. C-^ 3 ^ °-H O -tQ a. \ X \ ;^\ 3 <T>UJ SO 3: * 0" o§3a. a s- z: CL ^fcCVl H OQ 0 3D- ^ ^3 g = i« S S 2s&s I so| siH- 2 » s ^§ &S >r? S S•*• o-= B iii «SB B 3- S" S 1 2 ON B- ^ •«S » gOS | ll * <5" 1 rI r--.l^ \\\ r-i- r-V- o » •»leeways or enclosuresom the point of penetration'the surface of the buildingf i + h ' - f J +- -i ' - f J + - -i ' - f J + - -i ' - f J + - n ' ~ f J + --i • - f J + - -i • - f J + - n ' ~ f j + _ i ->|^\ ^^/ <^J 1 1 i i i x \ 1>l f"^1 f xs o- o » o 5 om building-integrated• other photovoltaic system•e run inside a building• structure, they shall; contained in metalicK> — 1 r/i °° -""1 — ?J <-J 2 * 3 C/3IOQ -0 « *2,^ l «£ J 3 ' <*> K1 o t^2 2J n S<t/> ^ 1 3oJ Q.c ! rrTc» 1 J £ -£• on<L O a*i ;=; > €o JT > J >§T3 £>§§ o "" V ^-1 H\j PS sr U) g 5d Q6 o § nor* ^1 S^ i,<^ 0o U)<_/) 0 §a ^ 3 3 ! 1 §•-t OJo > M g ^-1 -f ^ Z(0 PS U) * 15=\ K>OQ to 53 0 > 0.— \ ~ ff "1") i I? / w C/ o s -— ^ S?^ "ffCD O ^^1 CO ^^ s-g = 2. 2 ^ ^ sr o o g" •«^-li 2i "a i ** WB s 2. a- n-»• *+• .~ s l J illli5* C <« ri OJ^ - O S i-» 2 f 5 33i 2,8 S" n » 1 0) 3to o rn> O rn J> po I OJ -t^-j OJ 00 C/3 — O(a U> — >tro oo 5i">o ^ M OCA _z; C/3n K) O >r wa CO Tl -0P sr 00 —t^> vooo~ — •v — ' oo•^ *•J^. U)=?°^OJ -J vO <|w — -O SUNPOWER' SPR-220 HIGH EFFICIENCY PV MODULE The SunPower SPR 220 module is designed for use in on grid residential and commercial systems where the highest module efficiency and energy delivery are critical Utilizing 72 series- connected A-300 solar cells, the SPR 220 delivers extremely high power density with total module efficiency approaching 18% Reduced voltage-temperature coefficient, exceptional low-light performance and high sensitivity to light across the entire solar spectrum mean maximum yearly energy harvest SunPower modules—innovative design, proven materials, outstanding performance FEATURES & BENEFITS Unique all-back contact solar cells with conversion efficiency up to 21 5% Low voltage temperature coefficient enhances high-temperature operation Exceptional low light performance and high sensivity to light across the entire solar spectrum maximize yearly energy delivery 1 Highest quality, high-transmission tempered glass provides enhanced stiffness and impact resistance Superior aesthetics back contact cells with no front side gndlmes and a black anodized frame 1 Aerospace style cell interconnects with in plane strain relief provide extremely high reliability 1 Advanced EVA encapsulation system with multi layer backsheet meets the most stringent safety requirements for high-voltage operation 1 A sturdy, black anodized aluminium frame allows modules to be easily roof mounted with a variety of standard mounting systems © August 2006 SunPower Corporation All rights reserved Specifications included in tfiis datasheet are subject to change without notice SPR 220 HIGH EFFICIENCY PV MODULE Unprecedented power density and exceptional energy production per peak kW LISTED UL 1703, Class C Fire Rating IEC 61215' Safety Class " Certlfied Document* 001-06637 Rev B SunPower Corporation® 18777860123 Email sales@sunpowercorp com www sunpowercorp com Engineered in California SUN POWER SPR-220 HIGH EFFICIENCY PV MODULE ELECTRICAL CHARACTERISTICS AT STANDARD TEST CONDITIONS (STC) STC is defined as irradiance of 1 OOOW/m2, spectrum AM 1 .5g and cell temperature of 25°C Peak Power' 2 Pmax 220W Rated Voltage Vmp 398V Rated Current lmp 5 53A Open Circuit Voltage V,,,. 48 3V Short Circuit Current \x 5 95A Series Fuse Rating 1 5A Maximum System Voltage 600V (UL) lOOOV(IEC) Temperature Co efficients Power -0 38%/°C Voltage -1368mV/°C Current 2 3mA/°C Module Efficiency 1 7 7% PTC Rating 203 2W j fV CURVE ! 60 — - - — \ 1 000 Watts/m2 25°C, AA 50 | i ! ";: ! ! 4oj; ; , i -I - »jr--i i- -i ! i53 3 0 ' i !e v - - r<25i- ! - , 20 i _ . i .. L _. i 1 10: j 0 5 l i I 00 ! . ij..;j : : j i ; , . j i; , : ., 0 5 10 15 20 2 • ~^<A 1 5g X : \ i >[ 1 :. . .' 1 . J J • !. j :.. :.: J J '.I. 5 30 35 40 45 50 i/olts 1 Peak Power Tolerance +/ 8% •' Power guaranteed (or 25 years See SunPower Limited Warranty for details MECHANICAL SPECIFICATIONS Length (mm) x Width (mm) 1 559 x 798 Thickness, including junction box (mm) 46 Weight (kg) 15 DIMENSIONS 2X042- 31 42 [798] -61 39- [1559] 1 81 [1200] 707 [180] 2969 [754] 2X042-4X066- © August 2006 SunPower Corporation All rights reserved Specifications included in this datasheet ore sub|ecl to change without notice Document* 001-06637 Rev B SunPower Corporation® 18777860123 Email sales@sunpowercorp com www sunpowercorp com Engineered in California PV Powered ~ Sunsational Page 1 of 3 PVPowerea Sunsational OSE OUR SOLAR INSTALLATIONS | SOLAR CAS£ STUDIES Menu Installation Support Technical Support Admin Loom String Sizing The String Calculator is for informational purposes only All calculations should be verfied by the installer Step 1 Select Module Values Module Manufacturer SunPower [ j Model [SPR-220 ri Module Summary STC Rating (Pmp) 220 Watts DC PTC Rating 203 2 Watts DC Celsius or Fahrenheit Fahrenheit! ; Mounting Type: Roof [ I. Lowest Ambient Temperature! 25 f !i j Highest Ambient Temperature 120 I I Max Power Voltage (Vmp) 40 Volts Open Circuit Voltage (Voc) 47 8 Volts Max Power Current (Imp) S 5 Amps Voltage Temp Coefficient (Voc) 0 1368 Volts/ Manual data submission [ Update Fields | Quick Glance Min String Max String Min PVP 2800 240V XV PVP 2000-120V PVP 2900-20SV PVP 3200-240V PVP 4600-203 PVP 5200-240 PVP 2500-240V PVP 3500-240V PVP 4800-240V 6 5 7 7 7 8 5 6 6 9 8 9 9 9 9 9 9 9 PTC Watts 1219 Watls 1016 Watls 1422 Watls 1422 Watls 1422 Watls 1625 Watls 1016 Watls 1219 Watts 1219 Watts Max PTC Watts Max Total Modules 3251 Watts 2438 Watts 3251 Watts 3251 Watts 5689 Watts 6502 Watts 3048 Watts 4267 Watts 5689 Watts 16 12 16 16 28 32 15 21 28 Step 2 Inverter Selection Select your PV Powered Inverter ! PVP Step 3 View String 1 String STC Watts 6 1 )20 Watts 7 l'>40 Watts 8 1/60 Watts 9 1980 Watts 2 String STC Watts 6 2640 Watts 7 3080 Watts 8 35 20 Watts 9 3960 Watts 3500-240V ul Calculation* PTC Watts 1219 Watts 1422 Watts 1625 Watts 1828 Watts PTC Watts 2438 Watts 2844 Watts 3251 Watts 3657 Watts CEC Watts 1164 Watts 1358 Watts 1552 Watts 1746 Watts CEC Watts 2328 Watts 2716 Watts 3104 Watts 3493 Watts MaxVoe 311 Volts 363 Volts 415 Volts 466 Volts Max Voc 311 Vclts 363 Vclts 415 Vclts 466 Vclts Max Vmp Min Vmp 240 Volts 200 Volts 280 Volts 233 Volts 320 Volts 266 Volts 360 Volts 300 Volts Max Vmp Hln Vmp 240 Volts 200 Volts 280 Volts 233 Volts 320 Volts 266 Volts 360 Volts 300 Volts Max Imp 5 5 Amps 5 5 Amps 5 5 Amps 5 5 Amps Max Imp 11 Amps 11 Amps 11 Amps 11 Amps http //www pvpowered com/string sizing php 2/27/2007 PV Powered ~ Sunsational Page 2 of 3 3 String STC Watts 6 3960 Watts 7 4620 Watts PTC Watts CEC Watts Max Voc Max Vmp Min Vmp Max Imp 3657 Watts 3493 Watts 311 VDlts 240 Volts 200 Volts 16 5 Amps 4267 Watts 4075 Watts 363 VDlts 280 Volts 233 Volts 16 5 Amps PJIersu Installation Support Technical Support Admin Login To the best of PV Powered Inc s knowledge the California Energy Commission (CEC) rebate size is based on the total install Solar Array Wattage up to the Maximum Continuous Power of the Inverter The Maximum Continuous Power is the wattage as shown on the name plate of PV Powered Inverters It is PV Powered Inc s understanding that the rebate will not exceed the Maximum Continuous Power or wattage as shown on the name plate of the Inverter Please be aware that the String Sizing Tool may calculate wattage over the Maximum Continuous Power of the converter Thus the amount of wattage indicated by the String Sizing Tool does not reflect eligibility for or the amount of any applicable CEC rebate and the String Sizing Tool may not be used for purposes of calculating a CEC rebate PV Powered Inc has no connection with the California Energy Commission and disclaims any responsibility for CEC rebates 01 calculation thereof If you have any questions regarding the CEC rebate program you should contact the California I nergy Commission Review Inverter Specifications DC Input AC Output Max Power (Watts DC) 4375 Max Power (Watts) 3500 Max VOC (Volts DC) 500 Nominal Voltage (Volts AC) 240 Operating Voltage Range (DC) 200 - 450 Utility Voltage Range (AC) 214 - 261 Max Input Current (Amps) 18 Max Output Current (Amps) 17 Overcurrent Protection (Amps) 20 Nominal Frequency (Hertz) 60 General Data CEC Efficiency Rating 95 5% Enclosure Aluminum - NEMA 3R UL 50 Standards Dimensions (WxDxH) 15\ \ x 7 5\ \ x 21 75\ \ Weight 85 Ibs Cooling Natural Convection Warranty 10 Years Complies UL Listed UL 1741, IEEE 519, IEEE 929, NEC 690 Standards Home Products Installation Support MyPVP Account About Us © 2006 PV Powered Inc Legal http //www pvpowered com/string sizing php 2/27/2007 PVP3500 & PVP2500 PVP Starinverter EXPANDED DC OPERATING RANGE Introducing the PVF2500 and PVP3500 the exciting new additions to the family of PVP inverters Based on PV Powered s second generation inverter technology demonstrated in the PVP5200, these inverters offer field-proven reliability and are now compatible with lower voltage modules Among the many exciting innovations in this new series the availability of the Starlmk™ web-based performance monitoring system will allow the installer and the homeownei to remotely track the output of their inverter to ensure maximum performance Coupled with PV Powered s comprehensive 10-year warranty these advancements allow the Starinverter series to deliver on reliability, efficiency, and lowest cost of ownership FEATURES • Expanded DC voltage operating range • Now compatible with lower voltage modules • Proprietary magnetics for increased efficiency • No power de-rating - requires no fan • Highest CEC weighted efficiency in power class • Field-proven reliability- 10-year warranty • Easy-to-read vacuum fluorescent display • UL 50, aluminum enclosure (NEMA 3R) • Aesthetically pleasing design blends well with any exterior 150SWScalehouse Loop Bend OR 97702 1-541-312-3832 WWWPVPOWEREDCOM • ©2006 PV Powered DIMENSIONS TOP FRONT i • \\ \ MOUNTING I •--'- W--4-« BRACKET ;', vf t '. t ! t POWER CHARACTERISTICS MODEL Continuous Output Power Weighted Efficiency Maximum System Voltage DC Input Range DC Operating Voltage Range Nominal AC Voltage Normal Output hequency Operating AC Voltage Range Operating Frequency Range Maximum DC Operating Current Maximum Continuous Output AC Current Maximum Output Fault Current (AC) Output Overcurrfnt Protection FCC Class B Compliant* DC ISC Input 'Pending test results PVP3500 3500W 95 5% 500V 200V 500V 200V 450V 240V 60Hz 214V -261V 593Hz 605Hz ISA 17A 18A 20A Yes 26A PVP2500 •^nKw^^BH^^n^^^B^M^^HV^BKi 2500W 94 5% 500V 140V - 500V 140V 450V 240V GOHz 214V - 261V 593Hz-605Hz 20A 12A 14A 20A Yes 26A CONSTRUCTION, ENVIRONMENT & CERTIFICATIONS LISTED MODEL I Enclosure Dimensions (W x D x H) Weight Cooling Relative Humidity Safety PVP3500 Aluminum 15" x 7 5" x 21 75" 85 Pounds Natural Convection 0% to 100% Condensing UL 1741, IEEE 519 IEEE929, NEC 690 PVP2500 Aluminum 15" x 7 5" x 21 75" 70 Pounds Natural Convection 0% to 100% Condensing UL 1741, IEEE 519 IEEE929, NEC 690 : ©2006 PV Powered : Installation Manual 214 SolarMount Code-Compliant Planning and Assembly T E C T O N I "MFfAII I F TA.I I CORK *>. SA&0& 3 r j 1 4 TLL F'.0~740 24 C C ^ "'X 510 7iO 24C5 vvww tecicmc IP ron- 29 March, 2004 Mr John Liebendorier UmRac, Inc 3201 University Blvd SE, Suite 110 Albuquerque, NM 87106-5635 Subject Engineering Certific ation tor UiuRac's SolarMount™ Universal PV Module Mounting System Dear Mr Liebendorfer, Attached is the UmRac Calculation worksheet and Installation Manual #2]4, Pub 040316-lu, Copyngnted by UmRac, Inc, March 2004,20 pages I have reviewed these calculations, and certify their results are accurate The calculations determine the design level forces for wind, as prescribed in the California Building Code The adequacy of the UNIRAC structure is demonstrated by the calculations The calculations also correaly- determine the anchorage requirements for the installation, and this requirement is properly represented in Installation Manual #214 The calculations are based upon 1 "The 2001 California Building Code, California Code of Regulations", based on the 1997 "Uniform Building Code, Volume 2 Structural Engineering Design Provisions", by International Conference of Building Officials, Whittier. Ca, 1997, and California Building Standards Commission, Sacramento, California, 2001 2 'Manual of Steel Construction Load Resistance Factor De sign", 3rd Ed, American Institute of Steel Construction, Chicago, IL, 2001 3 L Aluminum Design Manual Specifications and Guidelines for Aluminum Structures' , The Aluminum Association, Washington D C, 2000 4 Mechanical Properties of UNIRAC extruded rails and related components based on data . pbtamed from Walter Gerstle, PE, Department of Civil Engineering, University of New Mexico, Albuquerque, NM With this letter, I certify that UmRac SolarMount products v^ill be structurally adequate arid will satisfy the building codes listed above when they are installed per the "SolarMount Code- Compliant Planning, and Assembly", Installation Manual #214 Pub 040316-lu, Copyrighted by UmRac, Inc . March 2004 Please call me Sincerely questions^or concerns Brian TECTONICS Architects / Planners / p.g 2 AI i.h i reL Pl-iiintc. FRANCIKCO EMERYVILLE -8.00 Solid Aluminum Block CO Galvanized (Clear or Black) x— 1.63 3/8" threads Stainless Steel #304 "A1 Marin Solar we pride ourselves on qual- ity, aesthetics and performance Using TTI Flat Jacks and Flush Mount pioducts gives us that edge The biggest advantage is peace of mind from roof leads with the TTI Flat Jack flashing system " Roy Phillips President Marln Solar, Inc Assembly is quick and easy For more information on Thompson Technology Tel: 415.446.0103 Jhis product and other incijsines, Inc. Fax: 415,456.2834 available products, 81 Paul Dru/e Email: please contact us ai San Rafael. CA 94903 info@ir.ompsof.sec cori www.thompsoritec.corr! Installation Manual 214 SolarMount Code Compliant Planning and Assembly 4b . Or verify Maximum Foot Spacing and Determine Minimum Design Dead and Live Loads To minimize roof penetrations, consul! Table 3 (p 7) to deter mine Maximum Foot Spacing allowable for the Design Wind Pressure that you determined in Step 3 Find the make and model of the PV module you plan to install, then read or extrapolate Foot Design Live Loads and Dead Loads at the maximum spacing To meet code, you must verify that foot spacing is at or below the dimension listed and that the roof rafter assembly at your installation site has the capacity to withstand the sum of the Design Dead Load and Design Live Load for the speci fied spacing If they do not, try smaller footer spacing If the result is still not acceptable reloc ate the array to a stronger area of the roof or strengthen the inadequate framing elements For assistance, consult a local pi ofessional engineer 5 Verify acceptable Rail End Overhang Rail End Overhang (Fig 2) must equal 50 percent or less of foot spacing Thus, if foot spacing is 72 inches, the Rail End Overhang can be up to 36 inches In this case, two feet can support a rail of as much as 144 inches (72 inches between the feet and 36 mch( s of overhang at each end) 6 Ensure that Live Loads do not exceed Pull-Out Capacities Based on the characteristics of your roof rafter or truss lumber and the lag screws, consult Table 4 to determine the lag pull out capacity per 1 inch thread depth Compare that value to the minimum design live load per footing determined in Step 4a or 4b Based on these values, determine the length of the lag screw thread depth you require to resist the design live load To ensure code compliance, the lag pull out capacity per footing must be greater than the footing design live load If your SolarMount requires standoffs, always use at least two lag screws to secure the standoff to the rafter Figure 2 SolarMount foot spacing refers to the distance between feet on the same rail Over hang, the distance from end of the rail to the first foot, may be no more than half the foot spacing Table 4 Lag pull-out (withdrawal) capacities (Ibs) in typical roof truss lumber Douglas Fir Larch Douglas Fir South Engelmann Spruce, Lodgepole Pine (MSR I650f & higher) Hem Fir Hem Fir (North) Southern Pine Spruce Pine, Fir Spruce, Pine, Fir (E of 2 million psi and higher grades of MSR and MEL) Specific gravity 050 046 046 043 046 055 042 050 s/t shaft* 2/2 "thread depth 665 588 588 530 588 768 513 665 Lag screw specifications s/,6" shaft,* per 1 thread depth 266 235 235 212 235 307 205 266 3/s shaft* per 1 thread depth I [[: 304 269 269 243 269 352 235 304 rThread depth / , •; . .'(' '. (. .££•;.^! •=3:'t£.-=?.,:-==: L:=' 1 V Sources Uniform Building Code American Wood Council Notes (I) Thread must be embedded in a rafter or other structural roof member (2) Pull-out values incorporate a I 6 safety factor recommended by the American Wood Council (3) See UBC for required edge distances *Use fiat washers with lag screws 8 Installation Manual 214 SolarMount Code-Compliant Planning and Assembly Part III. Installing SolarMount with top mounting clamps This section covers SolarMount assembly where the installer has elected to use top mount ing clamps to secure modules to the rails It details the procedure for flush mounting SolarMount to a pitched roof Contents Laying out the installation area Laying out L feet Installing L-feet Laying out standoffs Installing standoffs Installing SolarMount rails Installing the modules Figure 3 Exploded view of a low profile installation mounted flush to the roof with L feet Table 5 Part quantities SMR Series SolarMount Rail Sets (model no = rail length in inches) Rails L-feet footing bolts 3/s flange nuts Table 6 Wrenches and torque Wrench Recommended size torque (ft-lbs) SMR48thru 106 SMR 120 thru 180 SMR 192 thru 216 4 6 8 'A" hardware 3/e" hardware 15 30 CT Series Clamp Sets (model no = modules accommodated) CT2 CT3 CT4 CT5 CT6 CT7 CT8 End damps 4 4 4 4 4 4 4 Mid damps 2 4 6 8 10 12 14 'A " module damp bolts 6 8 10 12 14 16 18 'A x % safety bolts 2 2 2 2 2 2 2 'A flange nuts 8 10 12 14 16 18 20 Caution Stainless steel hardware can seize up a process called galling To significantly reduce the likelihood of galling SAP T-EZE anti-seize lubricant has been included with your hardware Apply a very snull drop to the threads of all bolts before in stallation If more anti seize is needed substitute any lubricant. Clean Power Systems, Iric 13230 Evening Creek Di South Suite 203 San Diego, Ca 92128 (858) 748-3636 (858) 748-3939 Fax Lic#Cl 0-827138 Solar Panel Dead Weight for 4 SunPower SPR-220 Panels on Solar Mount Racking 1 Panel weight calculation Solar Module Weight = 35 2 Ibs Mounting System Weight = 15 4 Ibs Total Panel Weight = (4x 35 2) •+ 15 4 = 156 2 Ibs 2 Point Load Calculation Point Load 3 Distributed Load Calculation Solar Module Area Total Solar Module Area Total Spacing Area Total Area Distributed Load Total Panel Weight/Number of Feet 156 2/6 Feet = 26 0 Ibs 314x614 = 13 34 sq ft 4x1334 = 53 36 sq ft 3 x ( 25) x 62 8 - 3 sq ft 53 36 + 3 = 53 66 sq ft 1526/5366 - 281bs/sqft Timothy L Bosworth VP/RMO Clean Power Systems, Inc SYSTEMS Roof Framing Greg Orth Mailing Address 1251 Basswood Ave Carlsbad, CA 92008 Installation Address 1251 Basswood Ave Carlsbad, CA 92008 Roof Type 3 tab Shingle Roof Framing 2x6 Trusses @ 24" o c Type Flat Jack & Flashin§ Att?d Wlth 2ea 5/16"x3 1/2" Lag Bolts @ Framing Members Attachement Spacing 48" to IT max spacing (two rows / row of panels) Combi-Switch Disconneeti and P¥ Asray $0% Introducing SMA America's new Combi Switch specifically designed for use with the Sunny Boy 6000U inverter The Cornbi Switch conveniently combines both an external DC disconnect switch and PV string fusing all in one compact enclosure Simply mount the Combi Switch next to the inverter connect the field wiring and you re done The rugged NEMA 3R enclosure allows for outdoor installation Designed with installers in mind, we know you'll find the new Combi Switch a wel come addition to our great line of Sunny products PV Array Utility Grid 240/208 VAC WYE The new Combi Switch was specially designed with installers in mind It provides the c ode required external DC disconnect and protection for the SB6000U inverter all in one small enclosure The Combi Switch allows for up to four PV strings to be landed on individual Touch Safe™ fuse holders 10 Amp fuses are provided for PV string over current protection The fuse outputs are then combined and routed through the disconnect switch One pair of wires conveniently connects the entire PV array to the SB6000U s DC inputs The familiar enclosure is NEMA 3R rated for outdoor installation Numerous knockout rings are provied for simplified conduit installation The Combi Switch is also ETL listed to UL 1741 Please contact your distributor for additional information and availability Specifications Number of Inputs Pos Input Wire Size Pos Input Terminal Torque Neg Input Wire Size Neg Input Terminal Torque Output Wire Size Output Terminal Torque Max Input Fuse Rating Max Output Current Max Voltage Max Cont Output Current Max Number of Outputs Enclosure Type Weight Dimensions (with handle) HxWxD (inches) 10to8AWG 14 mlb 10to8AWG 35 mlb 6 to 2 AWG 40 mlb 10 A 600 VDC Midget 40 ADC 600 VDC 32 ADC 1 Positive 1 Negative NEMA3R Steel 10 Ibs (approx) 150x775 x 5 75 Combi Switch Interior SMA America Inc Grass Valley CA USA mfo@sma amenca com www sma amenca com Solar Today Energy Tomorrow cx> 3 i! J* aou 00 o o m m;o O) ms CO zo mCO en !i i i i ii Ii >H ? 1 4 $5TOss 1 1of3mm U X2?mTj(D