Loading...
HomeMy WebLinkAbout135 REDWOOD AVE; ; CB142379; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 03-09-2016 Patio/Deck Permit Permit No: CB142379 Building Inspection Request Line (760) 602-2725 Job Address: 135 REDWOOD AV CBAD Permit Type: PATIO Status: ISSUED Parcel No: 2042531500 Lot #: 0 Applied: 09/17/2014 Valuation: $4,273.00 Construction Type: 513 Entered By: RMA Reference #: Plan Approved: 03/09/2016 Issued: 03/09/2016 Inspect Area: Plan Check#: Project Title: HOROWITZ RES-ADD 229 SF DECK TO EXISTING DECK @ FAMILY ROOM, ADD 3 SLIDING DOORS, ADD LIGHTS & SWITCH, MOVE GAS LINE FOR BBQ & ELECT FOR SPACE HEATERS Applicant: Owner: B B ARCHITECTS INC HORWITZ BRAD CALIFORNIA PROPERTY TRUST 07-28-11 STE 18 PMB 486 1590 SOUTH COAST HIGHWAY 3020 ISSAQUAH PINE LAKE SE LAGUNA BEACH CA 92651 SAMMAMISH WA 98075 425 584-0514 Building Permit - $70.09 Addi Building Permit Fee $0.00 Plan Check $49.06 AddI Plan Check Fee $21.18 Strong Motion Fee $1.00 Green Bldg Standards (5B1473) Fee $1.00 Renewal Fee $0.00 AddI Renewal Fee $0.00 Other Building Fee $200.00 Additional Fees $0.00 I TOTAL PERMIT FEES $342.33 Total Fees: $342.33 Total Payments To Date: $342.33 Balance Due: $0.00 sn rtnr ___________ FINAL.tPPROVAL In _____________ Date: 21 11 Clearance: NOTICE Flease take NOTICE M appud dxir pqed irdudes the '1rrtith dfees, dedcabce resenrdons, or d1weicT5 hereaft& collectively rdèrmd toes feei You have 90 days the date this pemites issued to ptest irrtim of these feeslezticns. lfi pntest then ai rrt fdIaN tie protest pxakres set fath in G,amErd Code Sedion 66020(a), ard file tie peteet and aiy ether red h fon , onWththeatykbnagerfor- puessing in amdate Wth Calsberi Minidpel Code Section 3.32 030. Faãkte totirrdyfdlowtiet pecethewll arf sitseqad lI action toattaic rL*Aew, set aside, void, or a-ni their intian. You are hereby RR RND11REDttet yox nt to protest the speofied fees/aredkxe DOES NOTAPRYtometwax1 seer crn,edicn fees and capacity dwiges ru planing, wing gacng or ether smiler application pmessing or serce fees in wnectim wth this pqed. NCR DOES ITAPR_Ytoany ITHE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: DPLAHNIUO LJENSIUEERIUO DRUILDING Drin€ DHEALTH IJHAZMAT/APcD Building Permit Application Plan Check No. C~4 z .gon> 1635 Faraday Ave., Carlsbad, CA 92008 CITY OF Est. Value Plan Ck. Deposit 760602-2717/2718/2719 CI\RLSBAD Fax: 760-602-8558 www.carlsbadca.gov 1j- DateT )--::—) Is` JOB ADDRESS j NAfE/SI'ACEA/UUflE if vJ1° ESJ1 /5ó'c .yPIo)Wre DESCRIPTION OF WORK; nctuiiito FctOfi OCICtJAVOO(s OJi2D/r/O,1J .' Al 0/0 'ç7: Z42 4t 1 /J' rn liZi A J\A4A4J 4'&1 1Qt L ISE PROPOSED USE PATIOS(5F) IlONINO WPEOAN?O*nte-tpnmj,ar IQJIIad IPFCKS(SF)f AIRCONDI YES I FIRE SPRINISPRINKLERS 1FIRFPLACr; 0 #__NOD YES 0 NO U YES 0 NO U - APPLICANT NAME iSeconhla,, Contact) ADDRESS AAQ oLJflL City STAlE - ZIP FAX P11011E IFAX FMAIL PROPERTY CONTRACTOR BUS. NAME ADDRESS J1DflESS CITY srAlF: ZIP cliv Jw Hot EA L~L I PHONE FAX 4zz7Ti 11i7V&1. eMAIl. :e .a0t 'ESlGULIt IIAMO A ICIAS (Sec. 70315 Business and PO!CSSIOIIS code: Any City or County which requiter; a permit to conowucl otter. Improve, demolIsh or meal; unGL(uCIUtO. 0liar 101W ISSUanCe. also requires we appltcrsnt(01 SUCh permit to (do a slJ31Od statement that he Is licensed pursuant to the iuovislona of tho COntraC(oe's Uccnso Low (Cheptcr . commondinjvi1th Section 7000 of DivIsion 3 Of the Business and Vsofesslons Code) 0? mat no Is axcmet therotiOm, and the basis for (ho olegOd exemption. Any V1011111011, Of SectIon 10315 Ityony applIc4ill .or o poenit subjects (ho applicant (On eMI rnnnlw inn net mere then Ann hundred drillers IRSOOD. All- i&Gi I1kn,1J - Workers' Compensation Declaration: I hero byefllmi widarpenafyo(pewyono of the (oiImn*rg derjarntians: - C] I have and will maintain a certificate of consent to sell-Insure lorwodrers compensatIon on provided by Section 310001 the alas Cede, for the pedermanco 01 the vvdc iorvhith this permit Is Issued. Ci I have and will maintain workers' compensation, as required by Section 310001 the Labor Cede, for the peafomiance of lhewcdc IoewtM this permit Is Issued. My workers o3mpellsa6on Insurance carrier and poky number are: insurance Co._- - Policy Mn ___________________________ ExpiratIon Dale This molten need not be ccxepieled lithe pernolts for one. hundred dollars ($100) or less. Cl Certificate of Exemption: I certify that In the performance 01 the teeth for which thin permit Is Issued, I thou not employ any person in any mariner so as to become sutcct to the Workers Compensation Less 01 Cofionnia. WARNING: Failure to secure workers' compeneatloti coverage Is unlawful, and shalt subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&I00,000),I4 addition to the cost of compensation, damages as provided for In Section 3100 of the Lebo( coda Interest and attorneys (ean. CONTRACTOR SIGNATURE CIACENT DATE ORAW ItI, s)r1iaJ3]Ild NO. I! hcuoby alOne Ihaliwn examp1 from Conl,ecWsikonso Eawfa-IhoIoier#Anfrreaccn: 0 I, esonnerof the popeily or owl e.upioyees With wayes as thab solo comperlsollon, toll do the work and this slitictuntfs net blended or offered lee solo tSco. 7044, Butrrois and Professions Code: The Contractor's Dowse Lovithes no(eppfy to armoamirol piopai ty wto builds or Improves thereonk and who does sucim ticak h'snself or gwcmujlm his ompiopeec, piwided Oral such batiroveements we net Intended of offered for $00. It h045mo,the Witfirgor improvement lssoyimititincemoyoaroiceenp!eton thooanor.bssderwtlmure the Loden ofprovinythathodi eel LIM Of iMp(011e for Umopurposeof solo). ji I, as caner of the property, ale esduoioelyconlracliny with (canned onlnertofs 10 conskucl the project (Sec. 7014, Business and Piolessloims Code: The Contractor's License law does not apply loon oat-er at property who builds or Improves thereon, and contracts for such pc0ec1s smith contractor(s) (cented pursuant to the Contractor's License tea). O I am exempt under Section ..Bsslness and Professions Code for this reason: 1. 01D.I.I ontraded sly plan to provkfo the mar labor and materials for construction of the proposed property Improvement. 13 Yea no 2.have aol) signed an appcaf-ols for a bta!dng permit for lime proposed wo& 3.wlth thea bthmlflg person (tirmn) to provide the propóOd corisiniction (Include name address 1phofte /contractors' license nomher) 4. !i an to provide portions of the static bull have Itincd (ho jtillowAg phon Lu ceonlinale supervise and preside the major work (include earns! address! phone !coaectors' fc€nsO oumbe(): S. IeWprontde some ol the andc but l have cormtroc the foimg persons Io provide thowodrmndicaIed(inciudencmeIaddressIptSae! type ofo0eIm .,'PROPERTY OWNER bi ClAGENT DATE 'If r.i Ira -1111 S~Su. ..pILpgyu:IJJ • - - Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley.TannerHazardous Substance Account Act? 0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? DYes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 1 DYes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. I. rplrsiu I1I1 . - I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name , Lender's Addreàs 1 - IcerIitythatlhave,ead the application and state thatthe above intbimation is correct and that the information on the plans is accurate. lagise to complywith all Cityordinances and State laws relating to buildingconstnjction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY INCONSEQUENCE OF THE GRANTING OF THIS PERM OSHA An OSHA permit is required for excavations over 69 deep and demolition or construction of structures over 3stories in height EXPIRATION: Every permit issued by the Building Official under the prottutons of this Code shall expire by limitation and become nuD and void fithC building or work authorized by suchpemdt is not commenced within 180 days horn The daleofsuth rif the buildingorworkauthorized ysuch it is su pond or abandoned at any time after the work is commenced bra pe I 180d (Section 106.44 Uniform Building Code). ,gAPPLICANT'S DATE STOP: THIS SECTION NOT REQUIRED FORBUILDING PERMIT ISSUANCE. Complete the following ONLY ifa Certificate of Occupancy will be requested at final inspection. IF,IC ATE .X4II I.I cur I Project si0T1 ITJ Fax (760) 602-8560, Email wwwbuiIdinacarlsbadcapov, or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. colt: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP , CITY - STATE ZIP Carlsbad CA PHONE FAX - EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS 0 PICKUP: o CONTACT (Listed above) o OCCUPANT (Listed above) - - - CONTRACTOR (On Pg. 1) 0 MAIL TO: o CONTACT (Listed above) o OCCUPANT (Listed above) ASSOCIATED CB# CONTRACTOR (On pg. 0 NO CHANGE IN USE / NO CONSTRUCTION 0 MAIL! FAX TO OTHER: CHANGE OF USE/ NO CONSTRUCTION ZAPPLICANT'S SIGNATURE . DATE Permit Type: BLDG-Residential Application Date: 09/17/2014 Owner: TRUST HORWITZ BRAD CALIFORNIA PROPERTY TRUST 07-28-11 U Work Class: Patio Issue Date: 03/09/2016 Subdivision: Status: Closed - Finaled Expiration Date: 03/1512017 Address: 135 Redwood Av Carlsbad, CA IVR Number: 702308 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 0312112017 03121112017 BLDG-Final 017139-2017 Passed Peter Dreibelbis Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes March 21,2017 • Page lofi Inspection List Permit#: CB142379 Type: PATIO HOROWITZ RES-ADD 229 SF DECK TO EXISTING DECK @ FAMILY ROOM, AD Comments Date Inspection Item 09/16/2016 17 Interior Lath/Drywall 09/16/2016 18 Exterior Lath/Drywall 08/31/2016 17 Interior Lath/Drywall 08/03/2016 13 Shear Panels/HD's 08/03/2016 14 Frame/Steel/Bolting/Weldin 08/03/2016 34 Rough Electric 06/06/2016 11 Ftg/Foundation/Piers Inspector Act MC WC MC AP PD AP PD AP PD AP PD AP PD AP Thursday, March 23, 2017 Page 1 of 1 EsGil Corporation In tFartnersfiip wit/i government for Bui(&ng Safety DATE: 05111/2015 U APPLICANT RIS., JURISDICTION: Carlsbad U PLAN REVIEWER i FILE PLAN CHECK NO.: 14-2379 SET: III PROJECT ADDRESS: 135 Redwood Ave. PROJECT NAME: Horowitz Residential Deck Add'n The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. E The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. El The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. LI The applicant's copy of the check list has been sent to: EsGil Corporation staff did not advise the applicant that the plan check has been completed. El EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Email: Fax #: Mail Telephone Fax In Person El REMARKS: By: Chuck Mendenhall (DA) Enclosures: EsGil Corporation l GA 0 EJ 0 MB 0 PC 05/04/2015 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (Partnership with government-for (Building Safety DATE: 01/05/2015 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-2379 SET: II PROJECT ADDRESS: 135 Redwood Ave. PROJECT NAME: Horowitz Residential Deck Add'n O PPLICANT rj URIS. .10 PLAN REVIEWER 0 FILE E The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. LII The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: B B Architects, Inc., Att'n: Donna Ballard 1590 S. Coast Hwy Ste #18, Laguna Beach, CA 92651 EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Donna Ballard Telephone #: (949) 494-2772 Date contacted (by: ) Email: d.olsenbbarchitects.com Fax #: (949) 494-2772 ~(s - M- 'tlMail Telephone Fax In Person REMARKS: By: Chuck Mendenhall (By DA) Enclosures: EsGil Corporation D GA 0 EJ 0 MB 0 Pc 12/26/2014 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Cr1sbd 14-2379 01/05/2015 NOTE: The items listed below are from the previous correction list. These remaining items have not been adequately addressed. The numbers of the items are from the previous check list and may not necessarily be in sequence. The notes in bold font are current. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. 2. Note on the plans that if not already existing provide smoke alarms with battery backup, per Section R314.1: Inside each bedroom. Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each story, including basements. Please note or show on plans compliance. This still applies. 3. Note on the plans that if not already existing provide carbon monoxide alarms with battery backup, per Section R315.2: Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each story, including basements. Please note or show on plans compliance. This still applies. 4. Guards (Section R312): Provide glass guardrail design to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. The design must show compliance with CBC Section 2407.1.2 NOTE: glass ballustrades must be designed for factor of safety of 4, CBC 2407.1.1 Your response appears to indicate that your intention is for this to be a deferred submittal, the note added to the plans calls for a separate permit for the glass rail. Please clarify. Alternatively revise the railing detail on sheet A-7 to include minimum requirements of CBC 2407 and a manufacturer, then annotate that equivalent may be used. Ctr1sbad 14-2379 01/05/2015 ENERGY CONSERVATION (FOR PLANS SUBMITTED AT-E- 7/1/14) For plans submitted for plan check on or after 711114, provide a Prescriptive or Performance energy design, demonstrating compliance with current 2013 energy efficiency standards. Information and Forms are available at: www.energy.ca.qov/tit1e24/2013standards This applies to the new glass doors. Registration is not needed; however energy design is still required. Additions (Prescriptive): Additions under 300 square feet and alternations (such as waterheater or window replacement) that do not require HERS testing do not require energy documentation. Energy design compliance is required however. ES 10-103.(a)1.0 To meet the prescriptive requirements, all that is needed is the U-Factor and SHGC of the new glazing. END OF PLAN REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. EsGil Corporation In cPartnership with government for Bui&(ing Safety DATE: 9/25/14 JURISDICTION: Carlsbad PLAN CHECK NO.: 14-2379 PROJECT ADDRESS: 135 Redwood Ave. SET:I OjAPPLICANT % JURIS. PLAN REVIEWER I FILE PROJECT NAME: Horowitz Residential Deck Add'n The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's codes. E The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: B B Architects, Inc., AWn: Donna Ballard 1590 S. Coast Hwy Ste #18, Laguna Beach, CA 92651 LII EsGil Corporation staff did not advise the applicant that the plan check has been completed. EsGil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Donna Ballard Telephone #: (949) 494-2772 Date contacted:/ (byy Email: d.olsen@bbarchitects.cOm Fa~x# : xs "ail Telephone 4ax In Person III1 REMARKS: By: Chuck Mendenhall Enclosures: EsGil Corporation DGA EJEJMB El PC 9/18/14 9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576 Carlsbad 14-2379 9/25/14 PLAN REVIEW CORRECTION LIST SINGLE FAMILY DWELLINGS AND DUPLEXES PLAN CHECK NO.: 14-2379 JURISDICTION: Carlsbad PROJECT ADDRESS: 135 Redwood Ave. FLOOR AREA: 230 sq ft new deck STORIES: 2 HEIGHT: no change REMARKS: DATE PLANS RECEIVED BY JURISDICTION: DATE INITIAL PLAN REVIEW COMPLETED: 9/25/14 DATE PLANS RECEIVED BY ESGIL CORPORATION: 9/18/14 PLAN REVIEWER: Chuck Mendenhall FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the California version of the International Residential Code, International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinance by the Planning Department, Engineering Department, Fire Department or other departments. Clearance from those departments may be required prior to the issuance of a building permit.. Present California law mandates that construction comply with the 2013 edition of the California Code of Regulations (Title 24), which adopts the following model codes: 2012 lRC, 2012 IBC, 2012 UPC, 2012 UMC and 2011 NEC. The above regulations apply, regardless of the code editions adopted by ordinance. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of the 2012 International Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i.e.. plan sheet number, specification section, etc. Be sure to enclose the marked up list when you submit the revised plans; Carlsbad 14-2379 9/25/14 Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete. Provide a statement on the Title Sheet of the plans stating that this project shall comply with the 2013 California Residential Code, which adopts the 2012 IRC, 2012 UMC, 2012 UPC and the 2011 NEC. Section R106.1. 2. Note on the plans that if not already existing provide smoke alarms with battery backup, per Section R314.1: Inside each bedroom. Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each story, including basements. 3. Note on the plans that if not already existing provide carbon monoxide alarms with battery backup, per Section R315.2: Outside each separate sleeping area in the immediate vicinity of the bedrooms. On each story, including basements. 4. Guards (Section R312): Provide glass guardrail design to show capability to resist a concentrated load of 200 pounds in any direction along the top rail. Table R301.5. The design must show compliance with CBC Section 2407.1.2 NOTE: glass ballustrades must be designed for factor of safety of 4, CBC 2407.1.1 5. Specify on the plans the following information for the water proof deck finish materials, per Section R106.1.1: Manufacturer's name. Product name/number. ICC approval number, or equal. 6. Specify on the plans whether the existing house was built before or after 1994. For additions or improvements to a residence built before 1994, note on the plans that existing "noncompliant" fixtures (toilets that use more than 1.6 gallons of water per flush, urinals that use more than one gallon of water per flush, showerheads that have a flow capacity of more than 2.5 gallons of water per minute, and interior faucets that emit more than 2.2 gallons of water per minute) shall be replaced. Certification of compliance shall be given to the building inspector prior to final permit approval. California S13407. St Carlsbad 14-2379 9/25/14 . RESIDENTIAL GREEN BUILDING STANDARDS The California Building Standards Commission has adopted the Green Building Standards Code which became effective January 1, 2011 and must be enforced by the local building official. The following mandatory requirements for residential construction must be included on your plans. 'CGC Section 101.3. The Standards apply to newly constructed residential buildings, ongwi dditons/alteràtuonsJhatncrease the bidng's conditionedre, volume or size CGC Section 303.1.1. Provide a sheet on the plans labeled "Green Building Code Requirements" and include the following notes as applicable. Recycling. Note on the plans that a minimum of 50% of construction waste is to be recycled. CGC 4.408.1. Pollutant control. Note on the plans that VOC's must comply with the limitations listed in Section 4.504.3 and Tables 4.504.1, 4.504.2, 4.504.3 and 4.504.5 for: Adhesives, Paints and Coatings, Carpet and Composition Wood Products. CGC 4.504.2. Note on the plans that prior to final inspection the licensed contractor, architect or engineer in responsible charge of the overall construction must provide to the building department official written verification that all applicable provisions from the Green Building Standards Code have been implemented as part of the construction. CGC 102.3. . ENERGY CONSERVATION (FOR PLANS SUBMITTED AFTER 711114) For plans submitted for plan check on or after 7/1/14, provide a Prescriptive or Performance energy design, demonstrating compliance with current 2013 energy efficiency standards. Information and Forms are available at: www.energy.ca.qov/tit1e24/2013standards This applies to the new glass doors. Additions (Prescriptive): Additions under 300 square feet and alternations (such as water heater or window replacement) that do not require HERS testing do not require energy documentation. Energy design compliance is required however. ES 10-103.(a)1.0 END OF PLAN REVIEW To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 858/560-1468, to perform the plan review for your project. If you have any questions regarding these plan review items, please contact Chuck Mendenhall at Esgil Corporation. Thank you. Carlsbad 14-2379 9/25/14 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLAN CHECK NO.: 14-2379 PREPARED BY: Chuck Mendenhall DATE: 9/25/14 BUILDING ADDRESS: 135 Redwood Ave. BUILDING OCCUPANCY: R3 BUILDING PORTION AREA (Sq. Ft.) Valuation Multiplier Reg. Mod. VALUE ($) deck 230 City est 4,273 Air Conditioning Fire Sprinklers TOTAL VALUE 4,273 Jurisdiction Code Icb Ordinance Bldg. Permit Fee by Ordinance Plan Check Fee by Ordinance Type of Review. E Complete Review El Other EjRepetituve Fee Repeats 11 Hourly EsGil Fee I $70.241 I $45.661 0 Structural Only Hr. © * Comments: jn addition to thee an additional fi 00 is due (j/2hou $43.00Ihr for the CàlGreen reviE Sheet I of I macvalue.doc + PLANNING DIVISION 401!h> BUILDING PLAN CHECK CITY OF APPROVAL CAR LSBAD Develooment Services Planning Division 1635 Faraday Avenue (760) 602-4610 www.crIsbdcov DATE: 2/9/15 PROJECT NAME: Horwitz Deck Addition PROJECT ID: CDP 14-25 PLAN CHECK NO: CB 14-2379 SET#: ADDRESS: 135 Redwood APN: 204-253-15 This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Garcia A Final Inspection by the Planning Division is required Yes M No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: Donna Ballard For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.Sexton@carIsbadca.gov Kathleen.Lawrence@carlsbadca.gov Grego ry.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carIsbadca.gov Linda.ontiveros@carlsbadca.gov Cynthia.Wong@carlsbadca.gov Chris Garcia [11 Dominic Fieri 760-602-4622 760-602-4664 Chris.Garcia@carIsbadcaov Dominic.Fieri@carIsbadca.gov Remarks: Plans consistent with CDP 14-25. CITY OF CARLSBAD PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division APPROVAL 1635 Faraday Avenue (760) 602-4610 P29 www.carIsbadca.ov DATE: 12/24/14 PROJECT NAME: Horwitz Deck Addition PROJECT ID: CDP 14-25 PLAN CHECK NO: CB 14-2379 SET#: ADDRESS: 135 Redwood APN: 204-253-15 This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Garcia A Final Inspection by the Planning Division is required El Yes Z No You may also have corrections from, one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: Donna Ballard For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.sexton@carlsbadca.gov Kathleeniawrence@carlsbadca.gov Gregorv.Ryan@carlsbadca.gov Gina Ruiz Linda Ontiveros Cindy Wong 760-602-4675 760-602-2773 760-602-4662 Gina.Ruiz@carIsbadca.gov Linda.Ontiveros@carlsbadca.gov Cynthia.WonE@carlsbadca.gov Chris Garcia Dominic Fier! 7 60-602-4622 760-602-4664 Chris•Garcia@carlsbadca.gov Dominic.Fieri@carlsbadca.gov Remarks: Plans consistent with CDP 14-25. Notice of Restriction required to be submitted prior to building permit issuance. NOR mailed to applicant 11/12/14. PLANNING DIVISION Development Services BUILDING PLAN CHECK Planning Division 1635 Faraday Avenue CITY OF REVIEW CHECKLIST (760)602-4610 CARLSBAD P28 DATE: 9/18/14 PROJECT NAME: DECK PROJECT ID: PLAN CHECK NO: CB142379 SET#: ADDRESS: 135 REDWOOD AV APN: O This plan check review is complete and has been APPROVED by the Division. By: A Final Inspection by the PLANNING Division is required J Yes N No You may also have corrections from one or more of the divisions listed below. Approval from these divisions may be required prior to the issuance of a building permit. Resubmitted plans should include corrections from all divisions. This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check Comments have been sent to: D.OLSEN@BBARCHITECTS.COM For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING ENGINEERING FIRE PREVENTION 760-602-4610 760-602-2750 760-602-4665 Chris Sexton Kathleen Lawrence' Greg Ryan 760-602-4624 760-602-2741 760-602-4663 Chris.Sexton@carlsbadca.gov Kathleen.Lawrence@carIsbadca.gov Gregorv.Ryan@carIsbadca.gov Gina Ruiz [J Linda Ontiveros J Cindy Wong 760-602-4675 760-602-2773 760-6024662 Gina.Ruiz@carIsbadca.gov Linda.Ontiveros@carIsbadca.gov gynthia.Wong@carlsbadca.gov Dominic Fier! 760-602-4664 Dominic.Fieri@carIsbadca.gov Remarks: 4 Plan Check No. CB142379 Address 135 REDWOOD AV Date 9/18/14 Review #1 Planner GINA RUIZ Phone (760) 602-4675 Type of Project & Use: DECK Net Project Density: DU/AC Zoning: General Plan: BJ:i Facilities Management Zone: 1 CFD (in/out) #_Date of participation:_____ Remaining net dev acres:_____ (For non-residential development: Type of land use created by this permit: REVIEW #: 1 2 3 Z Item Complete IJ Item Incomplete - Needs your action Z 0 0 Environmental Review Required: YES 0 NO Z TYPE DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: (HOUSE ORIGINALLY BUILT UNDER CDP 01-04) 0 0 Discretionary Action Required: YES 0 NO Z TYPE APPROVAL/RESO. NO. DATE___ PROJECT NO. Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: 0 0 0 Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES NO 0 CA Coastal Commission Authority? YES 0 NO If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive, Suite 103, San Diego, CA 92108-4402; (619) 767-2370 Determine status (Coastal Permit Required or Exempt): COASTAL DEVELOPMENT PERMIT REQUIRED AS THE PROPERTY IS LOCATED WITHIN 300 FEET OF THE INLAND EXTENT OF THE BEACH IZ 0 IJ Habitat Management Plan Data Entry Completed? YES 0 NO Z If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application and assess fees in Permits Plus (A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, HMP Fees, Enter Acres of Habitat Type impacted/taken, UPDATE!) Inclusionary Housing Fee required: YES [] NO (Effective date of Inclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES 0 NO 0 (NP/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Housing Tracking Form (form P-20) completed: YES U NO E] N/A 9 City Council Policy 44— Neighborhood Architectural Design Guidelines Applicability: YES 0 NO Project complies: YES 0 NOD Page 2 of 3 07/11 Zoning: DECK ATTACHED TO HOUSE D 0 0 Setbacks: Front: Required 22 Shown 20. Interior Side: Required F Shown Street Side: -A- Required W/ Shown Rear: Required 107 Shown ED 0 0 Accessory structure setbacks: N/A Front: Required Shown Interior Side: Required Shown Street Side: Required Shown Rear: Required Shown Structure separation: Required Shown 0 0 IJ Lot Coverage: Required 60% max Shown NOT STATED 0 0 0 4. Height: DECK Required Shown NOT STATED. Z 0 0 5. Parking: Spaces Required 20'x20' garage Shown 20x29.5' (breakdown by uses for commercial and industrial projects required) Residential Guest Spaces Required Shown El El El Additional Comments #1. PER SECTION 21.201 - COASTAL DEVELOPMENT PERMIT PROCEDURES, ANY IMPROVEMENTS TO EXISTING SINGLE FAMILY RESIDENCES Lir'i/ ),nri,r,i WHICH ARE LOCATED WITHIN 300 FEET OF THE INLAND EXTENT OF ANY BEACH fllid'(-4(-!I((VIV ARE REQUIRED TO SUBMIT FOR A COASTAL DEVELOPMENT PERMIT (CDP). IF THE ,77Jqc, VALUATION OF THE PROJECT IS UNDER $60.000. THE CDP WILL BE A MINOR. THE APPLICATION & SUBMITTAL REQUIREMENTS HAVE BEEN ATTACHED FOR YOUR REVIEW. PLEASE CONTACT THE PLANNING DIVISION AT 760-602-4610 FOR MORE INFORMATION. THE SIDE YARD SETBACK IS 5 FEET TO THE POSTS OF THE DECK. THE SITE K1j/ccp PLAN IS SHOWING 3 FEET. IF THE 3 FOOT MEASUREMENT IS TO THE OVERHANG. (f7 PLEASE REVISE THE PLANS AND INCLUDE SECTIONS THAT CLEARLY IDENTIFY &V[A9 THE MEASUREMENTS TO THE POSTS AND TO THE OVERHANG BEFORE THE (T'/1 FORMAL SUBMITTAL OF THE CDP. THE REAR YARD SEBACK TO THE STRUCTURE IS 10 FEET. THE SITE PLAN IS MEASUREMENT IS TO THE EAVES, PLEASE REVISE THE PLANS TO CLEARLY STATE THAT INFORMATION ON THE PLANS BEFORE FORMAL SUBMITTAL OF THE GOP. PLEASE STATE THE TOTAL LOT COVERAGE ON THE PLANS BEFORE FORMAL 2_ SUBMITTAL OF THE CDP. 15. PLEASE ADD THE TOTAL HEIGHT OF THE DECK TO THE SECTIONS SHOWN IN fsw THE PLANS. :w, çff( /9S OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE P-28 Page 3 of 3 07/11