Loading...
HomeMy WebLinkAbout1365 FOREST AVE; ; 86-506; Permit0 a)' 0• 'e) C USE BALL POINT. PEN ONLY & PRESS HARD - APPLICANT TO FILL IN INFORMATION WITHIN SHADED AREA AND DECLARATIONS. cc p.-'.i hereby affirm that I am licensed under . àvislàne of Chapter 9 (commencing with Section 7000) of• DivisIon 3 of the Business arId Professions Code, and my license is in Z L 'full force and effect. - I. hereby affirm that I am exempt from the Contrac- - 'tar's License 'Law' for the following reason (Sec. 7031.5 Business and Professions Code: Any city or county wfliclt re I ,quires a permit to construct, alter, improve, demolish, or repair any strociure. prior to its issuance also requires the ap- plicant for-such permit to tile a signed statement that he is -I licensed pursuant to the provisions of the contractors License Lam (Chapter 9 commencing with Section 7000 of - Divisiun 3 018e Business and Professions Code) or that is eu-empt therefrom and the basis for the alleged exemption.' Any violation of Section 7031.5 by an applicant bra permit sub-' ects the applicant to a civil penally ot, noi'mnre than live hun I' dred dollars ($500). Ii I. as,owner Of_the property, or my employees with wages 19 I - - as their sole compensation; will do the work, and the struc- . tore is not intended or offered for sale (Sec. 7044. Business - and Professions Code: the Contractor's License Law does I - not apply to an owner 01 property who builds or improves $ - thereon and who does such work himself or through his awn - employees, provided that such improvements are not Intend- Ulf - ed or offered for sale, it, however, the building or improve- Z ment is sold within one year of completion,- the ownnr'b'uiider will have the burden of proving that he 'did not build or im- prone for the purpose of sale(. - I,- as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, I Business and Professions Code: The Contractor's License Law dues not apply to an, Owner of property who builds or im- prnves thereon, and who contracts for each projects with a I CO contractor(s) license pursuant Is the Contractor's License Z Law).J. 0. As a homeowner I am improving my home, and the inflow- - bog conditions' exist: . ',, . '- I Cc The work is being performed prior to sate. - I have lived in my home for twelve months , prior to completion of this work. - Ui ' - - 3. have not claimed this exemption dUring the 'last last three years. . 'I 0 lam exempt under Sec. '••'''' . B & P.C. for this reason D.thereby affirm that I have a certiticate of Consent to - sell'insure. or a certificate of Worker's' Compensation In. su'rance. or certified copy thereof (Sec. 3800. Labor Code) I POLICY NO' COMPANY.'0. , "Copy is filed with the city 0 Certified copy is hereby tuirrisfied. Mi CERTIFICATE OF EXEMPTION FROM O WORKERS' COMPENSATION INSURANCE 0 t ;"iThin section need not be completed if the permit is for one hundred dollars iS100i,vr tenni Ui' 0 I certify that in the performance of the work for which -. this permit is issued. I shall not employ any person in any 'manner so auto become subject to the Workers' Compen' I sation Laws of California. - NOTICE TO APPLICANT: If. after rakiog this Certificate lbt of Euemptioe. you should become subject to the Workers' Com pen Oation provisions of the Labor Code, you must forthwith cèrpIy with such provisinosor this permit shall I rbe deemed revoked. -:': 45 , {' D1 t hereby aefirm that tfrore is a construction Ecinstruction lendingcc I agoncy for the performance of the work for which this per. I ol mil is issued (Sec. 3097; Civil Code( ZI WI Lender's Name ' L Lender's Address__________________________________ - C - CARLSBAD BUILDING DEPARTMENT - APPLICATION & PERMIT * 2075Las Palmas Dr., Carlsbad, CA 92009-4859(619) 438-1161 JOB ADDRESS % '' ' ' AV, ST. 3. NEARESTCROST. DATE OF APPLICATION BUSINESS LICENSE # VALUATION PERMIT NUMBER • ZONE -- , - -. -'I •' LOT I BLOCK SUBDIVISION ASSESSOR PARCEL NO. A ' CONTRACTOR I h$W0aJ CINTRACORS PHONE a OWNE'S NAME N - I PHONE OWNER'S - CONTRACTOR'S ADDRESS - '1 f" STATE LICENSE NO. BUILDING SO. FOOTAGE n A '7 -1'-- 4iu. L—- ,4Ø CAp 0 • 0 7) 00 OWNER'S M IL I, AD. ESS A ta - DESIGNER . DESIGN BA'S PHONE ¼6 tq) .• . ' z:A c , ? L( Al Al DESCRIPTION OF WORK DESIGNER'S ADDRESS STATE LICENSE NO. _ , --''- —% — - F/P FLR ELEV. NO GP ECU 1- OT A- EJ74-L- &A} , STORIES YO ND . . PARKING SPACE RES UNITS GRADING PERMIT ISSUED REDEVELOPMENT TYPE 0CC LOAD FIRE SPR AREA CONST -, Y O N 0' — Y O ND - Y O NO Not Valid Unless Machine Certified — QTY. , PLUMBING PERMIT - ISSUE SO QTY. MECHAN(CAL PERMIT- ISSUE 3 O' , SUMMARY/ACCOUNT NUMBER EACH FIXTURE TRAP ' . -' 1121 INSTALL FURN. DUCTS UP TO 100.000 BTU - - BUILDING PERMIT 001-810-00-00-8220 - / EACH BUlLDING.SEWER . . ' OVER 100,000 BTU - SIGN PERMIT 001-810-00-00'8221 / EACH WATERrHEATER AND/OR VENT BOILER/COMPRESSOR UP TO 3 HP PLAN CHECK 001-810-00-00-8821 EACH GAS SYSTEM'i 104 OUTLETS BOILER/COMPRESSOR 3.15 HP - TOTAL PLUMBING 001-810-00-00-8222 - EACH GAS SYSTEMS OR MORE '.' / -- , — METAL FIREPLACE . t - - ELECTRICAL - - 001-810-00-00-8223 EACH INSTAL.. ALTER, REPAIR WATER PIPE . , VENT FAN SINGLE DUCT- - MECHANICAL 001-810-00-00-8224 "7 EACH VACUUM BREAKER ' , MECH EXHAUST -HOOD/DUCTS . - 'MOBILEHOME- 001-810'00-00-8225 WATER SOFTNER - - - , - RELOCATION OF EA FURNACE/HEATER - - - -. - SOLAR - -'°- " 001-810-00-00-8226 - - EACH ROOF DRAIN IlTISlOEl - , , - DRYER VENT ' • . -STRONG MOTION 880-519-92-33 I .,. TOTAL MECHANICAL - - . ' 7 - FIRE SPRINKLERS 001_810-00-00-8227 — TOTAL PLUMBING I. 1A. PUBLIC FACILITIES FEE. 320-810-00-00-8740 - - BRIDGE FEE 360-810-00-00-8740 QTY. . ELECTRICAL PERMIT - ISSUE ' QTY: MOBILE HOME SETUP - - - - PARK-IN-LIEU (AREA NEW CONST.EA,AMPISWT/BKR - ' • - - . • • CAR PORT - - - - , ' ' . . ' •, T(F - 134-810-00-00-8835 - I PH - - '.. - - 3 PH , , AWNING ' . . LA COSTA TIF , 133-810-00-00-8835 EXIST BLDG EA AMP/SWT BKR , - " GARAGE I ' FMF - 3'P H A LICENSE TAX - 001-810-00-00-8162 REO0EL.'ALTER1 P,ER,1 CIRCU(T --' . ' . MFF - 880-519-92-57 - TEMP POLE' 200 AMPS OVER200AMPS TEMP OCCUPANCY' 130 DAYS) -. ... - -. ,- I , • . . , , ' . - . . - CREDIT DEPOSIT - TOTALEIELTRICAL - — ---:' TOTAL. TOTAL FEES PAYABLE --• I HAVE CAREFULLY EXAMINED THE COMPLETED "APPLICATION AND PERMIT" AND DO HEREBY Expiration. Every permit Issued by the Building Official under the provisions of this IJI *AAN OSHA PERMIT IS REQUIRED FOR EXCAVATIONS OVER CERTIFY UNDER PENALTY OF PERJURY THAT ALL INFORMATION HEREON INCLUDING THE Code shall expire by limitation and become null and void If the building or work • 50" DEEP AND DEMOLITION OR CONSTRUCTION OF DECLARATIONS ARE TRUE AND CORRECT AND I FURTHER CERTIFY AND AGREE IF A PERMIT IS authorized by such permit is not commenced within 180 days from the date of such permit, or if the building or work authorized by such permit is suspended r iuSTRUCTURES OVER 3 STORIES IN HEIGHT erIod ISSUED: TO COMPLY WITH ALL CITY, COUNTY AND STATE LAWS GOVERNING BUILDING CON- abandoned at any time after the work is commenced fas,n STRUCTION. of 180 dayo. 1 WHETHER SPECIFIED HEREIN OR NOT. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE Crry OF CARLSBAD AGAINST ALL LIABILITIES. JUDGMENTS, COSTS APPLICANT'S SIGNATURE ,ANE CONTRACTOR 0 VIED BY - ' - * D7L' EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT BY PHONE 0 L,& -3.__A_.--'---Q-.__._. I TYPE DATE INSPECTOR BUILDING FOUNDATION REINFORCED STEEL MASONRY - - GUNITEOR GROUT SUB FRAME LI FLOOR 'LI CEIJNG SHEATHING - LI ROOF LI SHEAR FRAME . EXTERIOR LATH / INSULATION • , INTERIOR LATH & DRYWALL (or PLUMBING LI SEWER AND BL/CO Li FL/CO UNDERGROUND LI WASTE q WATER TOP OUT WASTE a-WATER TUB AND SHOWER PAN GAS TEST I LI WATER HEATER LI SOLAR WATER. ELECTRICAL . LI ELECTRIC UNDERGROUND .-t(UFFER ROUGH ELECTRIC ELECTRIC /3( L...- LI ELECTRIC SERVICE. 0TEMPRA1RY LI BONDING . LI- POOL MECHANICAL LI DUCT & PLEM., El REF. PIPING V ... 'Y- -• HEAT - AIR COND. SYSTEMS VENTILATING SYSTEMS CALL FOR FINAL INSPECTION WHEN ALL APPROPRIATE ITEMS AR)VF HAVF RFFNAPPRflVFfl'- r FINAL' PLUMBING , y ELECTRICAL - - I '- MECHANICAL GAS BUILDING' /AL SPECIAL CONDITIONS I .\ \ . . FIELD INSPECTION RECORD REQUIRED SPECIAL INSPECTIONS , INSPECTOR'S NOTES - I INSPECTION REQ. IF INSPECTOR'S DATE CHECKED APPROVAL SOILS COMPLIANCE PRIOR TO - FOUNDATION INSP - ,STRUCTURA.CONCRETE y,ER 2000 RS(-- RESTRESSED POST TENSIONED - - CONCRETE FIELD WELDING HIGH STRENGTH BOLTS - - SPECIAL MASONRY PILES CAISSONS - . *'t't• .1 '- --- s flflT iT Tfl\9! 2 : -•' : - — — ) t - •. -- '7 -' . c - ' (,c.. Li r- I - -- ---- - .4 • ! --_________ ___________ ESGJLCOPORATION 9320 CHESAI'LAKE DR! SUITE 208 ., SAN DIEGO CA 92123 (619) 56() 1468 RJ - DATE +c6e..c 8e— [)APPLICANT , JURISDICTION:' CrId.' :- GPLAN CHECKER FILE COPY PLAN CHECK NO DUPS - D DESIGNER PROJECT. ADDRESS: /3,5 - - . - PROJECT NAME:.' The plans'ransmitted herewith have' been corrctedwle±e - U ' necessary and4substantiall comply with the .jurisdition's building codes * The.plans transmitted' herewith will substantially comply T with ,,the jurisdiction's building codes when minor deficien- '.. cies identified '-I&,-. , . are resolved and checked by building department staff.',' . Theplains -transmitted herewith have significant deficiencies LI identified on the -enclosed check list and should be corrected and resubmitted for acomple'te recheck. The' check list 'transmitted herewith is for your; information. The p-lans are 'being, held at Egil Corp. "until 'corrected plans are submitted for recheck The applicant's copy. of' the check list is' enclosed for the jurisdiction to return to the applicant contact person The applicant's copy of the check list has been sent to — :.•- * 4' . - F -. "V Esil staff did not advise the applicant contact person that plan check has been completed. , Esgil staff did advise applicant that the plan, check has beencompleted. Person-contacted: &j-i Kouc Date contacted: , - .Telephone #/ REMARK S,:.'(i)(',,4 -cr,i,r1c. ,. AüMj vi I r iLe rc sifr P 'rOt,r/y' Ir/et a-, -pcb'/i Cir a,d . -* I . By: Enclosures: - . ESGIL CORPORATION ' - - ESGIL CORPORATION 9320 CHESAI'EAKE DR.. SUITE 208 SAN flIEGO.CA92123 (619)5601468 4' DATE T13iJ z1 ii =URISDICTiot JURISDICTION: /1L5 OF) D ' NHECKEF U FILE COPY PLAN CHECK NO: - J DUPS U DESIGNER PROJECT ADDRESS \"3(,'' E~cpT fflJ ,PROJECT NAME 1ti2WoE / "Br91 cftit The plans tran'smitted herewith have. been corrected where necessary and substantially comply with the jurisdiction's building codes Y j The plans transmitted herewith will' substantially comply with the jurisdiction's building codes when minor deficien- cies identified - are resolved and checked by building department staff. The plans 'transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a 'complete recheck., r The check list transmitted herewith is for ,our:inform'ation. The plans are being held at Egil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person The applicant'spy of the check list has been sent to: co 8J fr 0A13 /3 Esgil'staff.'did not advise the applicant contact person that plan cheek has been completed. ' Esgil -staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone #j9- 4303 REMARKS:' JI,5CI )J,) 0FL1 AS R-3 Du)aiií ü4i/r Pr-,,e 'crmi Jw (Pre i 'r) By: '4W' ESGIL CORPORATI(9c1 L.SLLL. •J_ ,JO A•i. ' - - - - - - •. 'V V I 4 - - V - - - '' Date initial plan check completed JURISDICrION CITY OF CARLSBAD - Z - By (iciL1 MXOL - : - .•• Applicant contact person: - - - D i3i &IJ øOtV Telephone:- 13&6IgD-( FOREWORD PLEASE READ (j'IW)PJPIt) (1)F 12COE3 Plan check is limited to technical requirements contained in the Uniform Building Code, Unifoiin- 'Plumbing Code, Uniform Mechanical Code, nummE -it--4 3o National Electrical Code and state laws . - '. regulating energy conservation, noise - attenuation and access for the handicapped. o:.OsUR:' The plan check is based on 'regulations enforced - . - by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, - Engineering Departmentor other departments. Present California law mandates that residential construction comply with Title 24 PRDJ ADDRESS: and the following model codes: ' 1982 UBC (effl 7/1/85) - 1982 UPC (eff 10/1/ 85) L. 1984 NEC (eff. 10/1/85)' . •' - -. 1982 UMCJeff. 3/1/85) -. . The above regulations apply to residential V V ____________________________________________ construction, regardless of the code editions. . ' adopted b ordinance PLAN RRION SRE The circled items need clarification, ST1JiE FAMILY AND DUPLEX mJELLThGS modification or change. All items have to be satisfied before the plans will be in - -'- Date plans received by jurisdiction: conformance with the cited codes and regulations'. Per Sec. 303 (c), 1982 Uniform . V V . Building Code,' the approval of the plans does - - . • Date plans received by Esgil Corporation: - not permit the violation of any state, county • - V , orcity law. , - • To speed up the recheck proces,note on this • V V• list (or a copy) where each correction item has V V V • been addressed 'i.e., plan-sheet, specification. V V etc. Be sure to enclose the marked up list - ' V ,• V -: when you submit the revised plans. - V PACE NUGOM ARE NOT DI S34CE AS PAGES HAVIM NO IT 1DIG IONS WERE V V Carlsbad List 10, Single Family Dwelling - •V - r ::, V and Duplex With All Supplements V 1 3/25/86 V . • - •i •• V V _ V - - - - • V V • V V • - V A. PLANS $. . Indicate distance from center line of street - /or alley to property line and distance from Please make all corrections,on the original Qracings property lines to proposed building. and submit two new sets of prints, and Section 302 (c). any original plan sets that may have been returned to you by the jurisdiction, to: B. FflE PEEION Esgil Corporation, 9320 Chesapeake Drive, Walls closer than 3 feet to property lines Suite #208, San Diego, California 92123, 'shall be one-hour rated construction, have no (619) 5601468. • openings, and shall have 30 inch parapets when - the building floor area exceedi 1,000 square /1. Please make all corrections on the original feet on any floor. tracings and submit two new sets of prints, and (Table 5. A. Section .1709 (a)). any original plan sets that may have been returned to you by the jurisdiction, to: 10. Projections, iricluding eaves, may not extend more than 12 inches into the 3 foot The jurisdiction's building department. setback from the propertj line. Eaves over required windows shall be not less than 30 Indicate on the Title Sheet of the plans, - Qe inches from the side and rear property lines. name of the legal owner and name of PQIL Section 1710 and Section 504 (a) and (b). responsible fr the preparation of thp1ans_ . Section 302 (a) 7. . 14. Plastic'skylights shall not be installed - ,-.- 6tiifl 8' of an exterior wall located where fl. Plans, specifications and calculations shall openings in such exterior wall are prohibited or be signed by a California state licensed required to be protected. engineer or architect.' (California Business and Section 5207 (a) 7. Professions Code). - • 12. Projections, including eaves, shall be Specify on the Title Sheet of the plans the o e-hour fire-resistive construction, heavy gross floor area of each element of this project timber or of noncombustible material if they including dwelling, gaiage, carport, .patio, deck ' project into the 3' setback area from the and balcony. Section 302 (c). , property line. Section 1710. 6. Provide a statement on the Title Sheet of Show location of permanently wired smoke 9etector, e'plans that this project shall comply with centrally located in corridor leading Title 24 and 1982 TJBC, TJMC, and UPC and 1984 ., * to sleeping rooms or above stair if sleeping NEC. - - rooms are on upper level. Section 1210. - ,i. Submit fully dimensioned plot plan drawn to ]4. A smoke detector shall be installed in the scale showing location,' size, and use of all basement of dwelling units having a stairway existing and proposed structures on the lot, which opens from the basement fito the dwelling. Identify property lines and show lot dimensions Such detector shall be connected to a sounding and all easements. Show location of all cut or • device or other detector to provide an alarm fill slopes and approximate finish floor which will be audible in the sleeping area. elevations for all structures and show Section 1210. elevations at all lot corners. Section 302 (c). • :4 - . . - - C. ROOM SIZ, LI, VThTILAflON AND - 27L. Dimension on the plans, the 30" clear width Eor water closet compartments and 24" clearance Habitable rooms, other than kitchens,'shall in front of water closet. /contain at least 70 square feet of floor area. - Section 511 (a). Section 1207 (b). . Specify safety glazing for glazing in Window area must be at least 1/10 of the toor ' iazardous locations such as glass doors, glazing area and-a minimum of 10 square feetper' adjacent to such dcors and glazing adjacent to Section 1205 (a). Appears to be deficient in walking surfaces. Section 5406. • 2,. Glazing, in the sane wall plane as a door, djust be safety glazing if within 12" of the 'door • - and less than 6011 above the walking surface, ])J. Openable window area in habitable rooms unless the glazing is leaded on faceted glass. iust be 1/20 of the floor area and a minimum of Sec€iôn 5406 (d) 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and . ee Glazing in shower and tub enclosures shall minimum is 1.5-sq. ft. (Section 1205 (a)). tempered, laminated' or approved plastic (including windows'within 5 feet of tub or At least 1/2 of the common wall must be shower floor). Section 5406 (d) 5. 'open and have an opening not less than 25 sq. ft. if light and.ventilation is being supplied Sleeping rooms' shall have'a windowor ' Lrior from anadjacent room. Section 1205 (a). ' ' door for emergency exit. Sill height Required windows shall not open into a shall not exceed 44" above the floor. The window must have an openable area of at least Ioofed porch unless the ceiling is at least 7 -• ' 5.7 square feet with the minimum openable width, feet and the longer side is at least 65% open.' 20" and the minimum openable height 24". Section 1205 (a).- . - Section 1204. •' V 36. Provide mechanical ventilation capable of ' 2)). A mezzanine is an intermediate floor and providing five air changes per hour in /ny not have a floor area exceeding 33 1/3 bathrooms, water closet compartments, laundry V percent of the total floor area in the room rooms and similar rooms if required openable below. The mezzanine floor must have a clear windows are not provided. Section 1205 (a). height of 7 feet, above and below, and must have V V 'the long side open to the room below except for 2/i.. No habitable room, other than a kitchen, ' posts and protective walls or railings not shall be less than 7!0" in any dimension. V exceeding 42" in height. Section 1716. Section 1207 (c). 'V • - - - • Z. Show that ceiling height for habitable V /0. The loft j,rou show does not comply as a - , /nezzañine floor and is,,by Uniform Building Code - ooms is a minimum of 71 6". Section 1207 (a). definition, a story. Section 1716. - 2. Show ceiling height for laundry rooms, - V 1allways, corridors, and bathrooms is a minimum V ' • - .' V V of 710". Section 1207 (a). V • - - " •,. V -. - • - • V•, V V - '. - ' • V' 4' -. , - S. . .- • - .- C C D. 1TS, STAIRWAYS, AND RAILINGS . Every stairway landing shall have a terision, measured in the direction of travel, Floors above the second story shall.have at least equal to the stairway width. ,not less than 2 exits. Section 3303 (a).- - 2Setion 3.306 (g). • - a 34... Required exit doorways shall be not less - . - A door may open over a stairway landing 36" in width and not less than 6'S" in tvided the door, in any position, does not height, and shall be capable of opening at least , reduce the clear area of the landing in the 90 degrees. Section 3304 (e). • '.' direction of stairway travel, to:less than one-half the required width of the stairway. 33 Provide 36" high protective railing for Section 3306 (g). ' p rc . hes, balconies, and open sides of stair - - . landings. Openings 3etween railings shall be 3ft. A door may. open inward at the top-step of a less than.6". Section 1711. 40 Uldc-MSICW6 stairway provided .the topstep is not more than 7 1/2" lower than the flor level. Show how guardrail connection details are Section 3304 (h). - . • equate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. - Lk). Provide details of winding stairway éomplying with Section 3306 (d): Provide stairway and landing details. - ection 3306 (b) & (c)XI, a. Minimum tread is 6 inches,at any point and minimum 9 inches at a point 12 a: Maximum rise 8" and minimum run is -inches fiom where the treads are 9. - . . narrowest. - ,b. Minimum headroom is 61 6". - b. Maximum rise is 8 inches. Minimum width is 30". c.. Minimum width is30 inches. Q36. fl handrails per Section 3306 (j), shall sa isfy the following: Provide spiral stairway details,' per -• tection . 3306 (f): . Provide handrail for stairways with 4 a. Minimum run is 7 1/2 inches measured or more risers. . -- at a point 12 inches from where the treads are the narrowest. Handrail shall be 30" to 34" above the - nosing of treads. .- b. Maximum rise is 1/2 inches. C. The handgrip portion of handrail shall C. Minimum headroom is 6 feet 6 inches. - be not less than 1 1/4" nor more than • 2" in-cross-sectional dimension. - 42. Spiral stairways may not be used for (See attached). • required exits when the area served is greater than 400 sq. ft. Section 3306 (f). .1 - - - . I' -. '•'.'I - t3. Spiral stairways must have a clear walking 11 1 , 2.4.The maximum' slope for a fire retardant pace of 26 inches between the column and •, built-up roof, with rock o gravel surfacing, is handrail, show dimension Section 3306'(f)..,.3 inches in 12 inches, Section 3203'(e) 2 ,L. Provide I.C.B.0. Research Report and Number' 0. The minimum slope for a fire retardant Eor metal stairway, or submit plans and - built-up. roof, with cap sheet surfacing, is 1/2, calculations and approved fabricator registered inch in 12 inches. Section 3203(e) 3. with the building department or note-that the stairway fabrication shall be done under special"'.. 4. Specify minimum: 1/4 inch per foot roof inspection per the approved fabrication plans. ' slope for drainage or design to support Section 306 (a) 4B and Section 306(f). accümu1ated wter. Seótion 3207 (a), Section i'.. 2305 (f) and Section25l1'(d) 6. 4. ' In buildings over 2 stories in height, rovide 3/4 hour fire-rated assemblies for all '' /s. Show roof drain' ardvef lows. openings in the exterior wall below or within 10 Section 3207 -' feet horizontally of an exterior stairway. An. ,- 47 exit balcony with 2 separated stairways' is , , Provide skylight detai1.tó sho.' compliance exempt. Section 3306 (1). . 4i th Sections 3401 and 5207 or provide I.C.B.0. ' •- ' ' ' approval number. L • Exterior stairways shall not project into . ;I_ 3 foot setback from the property lines . Plastic skylight must be separated from Section 3306 (n). , tch other by at least 4 feet. - Section 5207 (a) 6. - -• The walls and soffits of the enclosed 4 -(isable space under interior stairs shall be "7'8. Show attic ventilation. Minimum vent area protected on the enclosed side as required for is 1/150'of attic area or 1/300 of attic area if one-flour tire-resistive construction. - at least 50%of the required vent is at least 3 Section 3306 (m). feet above eave vents or cornice vents. Show required area and area provided. ' B. ))OFI!E . Section 3205 ,(c). , Specify roof slope F MASONRY - Roof slope is not adequate for roof type Provide fireplace construction details oi specified. Table 32-B; Section 3203 (h). - note construction to be per attached fireplace 'standard drawing. apter'37.- -. Show veneer support-and connections in 50. Specify roof material and application. Qpter Seismic Zones 3 and 4, comply with Section 3002, 32.J -L- 4, 5, 6, and Section 2515(a) regarding ties and - - /1. Specify I.C.B.0. or U.L. approval number #9 wire in horizontal joints or show '- construction to be per 'attached sheets' - or roof materials not covered in U.B.C., e.g., .30-1-6r 30-2. title, etc., Section 107 - 4 " 4 - '. -. • , r ' Show height and construction details of all 7/6. Openings 'between carport and residence masonry walls. Chapter 24. require self-closing doors and stationary windows. Section 1214. Note that cleanout openings shall be lro-vid~edat the bottom of all cells to be grout -: Show garage framing section, size of header filled ~Ver garage opening, lateral cross bracing at over 4' ina single pour. Cleanout shall be sealed before groutin, after inspection, plate line, method of bracing garage front, and Section 2414 (a) 8. holddowns if required. Chater 23. 6 Show floor and roof connections to masonry NOTE: Maximum shear panel ratio of height to jails. Connection shall resist 200 pounds per width is 3 1/2 to 1. Table 25-I.' iineal-foot or the actual design load, whichever .• ,• is greater. Cross grain tension or bending in 7/L Doors may open into,,the garage only if the 'wood 1eders is not permitted. floor or landing in the garage is not more than Section 2312 (j) 3. A. 1/2" lower than the door threshold. - Section 3304 (h). • Provide details for damp proofing the , - • roLdation walls, below--finish grade, where Provide an l8"-iaisd platform for any FAU, Qer useable space Sexists on the interior side of the . heater, 'or other device in the garage, walls. Section 1707 -(d). which may generate a flame or spark, UMC Section '. 508, UPC Section 1310 (a). 5. Show a minimum 2" air space and flashing - fbetween planter and building,walls. H. FOUNDATION cvwIc1S. Section 2516 (c)7. . . - . . 74. Per soils report,noteon the plan the G. GARAGE AND CARPORTS us classification, whether or not thesoil is - expansive, and note the allowable bearing value. t. Garage requires one-hour fire protection on Section 2905 (c).1rs3 - e garage-side of walls and ceiling common to . . the dwelling. Table 5. B. Section 503 (d). 7,15. The fOundation plan does not comply with /the soil report recommendation for this project. All elements supporting floor above garage, . Qluding Please review the report and modify design, walls supportinj floor joists, to have notes and details as required to show- • c one-hour fire-resistive protection on the garage compliance. - - - • - side. Section 503 (a).C.(o. MOOr - - -. 76. Provide notes on the foundation piaii Show 1 3/8" solid core self-closing door ,sting the soils report recommendations for for openings.between garage and dwelling, foundations, slab and building pad preparation. - Section 503 (d). •. - • . Garages are not permitted to open into a room used for sleeping purposes Section 1104 - - •. - • - ' . . . - - • cc • c c 6' 3/25/86 • • -, . -.-- - - . . , , 1. The soils report recommends excavations be 71g.. Show foundation sills' to be pressure /reviewed by soils engineer. Note on the treated, or equal. SectionV2516 (c) 3 foundation plan that "Prior to the Contractor V V requesting a Building Department Foundation . . Show foundation bolt size and "spacing. tec'tion Inspection, the soils engineer shall adviseth •. 2907 (e). building official in writing that: . V . Specify size, I.C.B.0 number and i. the building pad was prepared in manufacturer of power drivenpiis. Show edge accordance with the soils report; and end distance and spacing.. V V Section 306(f). 2 the utility trenches have been V properly backfil led and compacted, 77. If required by stucturl calculations,*..- and; show size, imbedrnent and location of hold down V anchors on foundation plan: Section 2312 (f). 3 the foundation excavations, forinings 71 VV and reinforcements comply with the V Qte If holddowns are required by calculations, soils report andapproved plan". on plan that hold down anchors must be tied V V V V V V V Sho, height of all foundation walls. V V in place prior to foundation inspection. V 'Section 305 V(e) 2. V V V V Chapter 23 V V V V 8,. Show adequate footings under all bearing. V Show height of retained earth on all walls and shear walls. Section 2907 (b). - Eoundation walls. Chapter 23. .. V 710. Show onthe elevations, stepped footings V 80. If cut or fill slopes exist, show distahce V for slopes steeper .than 1:10. o foundation to edge of cut or fill slopes and V V Section 2907 (c). show steepness and heights of cuts and fills. V V Chapter 29. V V ll. Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" 1. Note on plans that wood shall be 6" 4inimum clearance to bottom of girders. above finish grade. Section 2516 (c).V V V V V Section 2516 (c)V7. V V V V V V on plans that surface water will drain Show pier size, spacing and depth into Note V soil. Table 29-A. V tdlistu'rbed away from building and show drainage pattern and . V V V V V V key elevations. Section 2905 (f). oh, . Show minimum underfloor access of 18" x V V Section 2516 (c): V V V 7 . Dimension foundation per U.B.C. Table 29A: V V 4. Show minimumunderfloor ventilation equal- Floors V (to 1 sq. ft. for each 150 sq. ft. of underfloor Supported* Stemwall Width Depth • area. Openings shall be as close to corners as V 1 6" 12" V 12" V practicable and shall provide cross ventilation 2 8" 15" 18" - V on at least two approximately opposite sides. ' 1011 18" 2411 . V Section 2516 (c). V •VV *Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. V - - V • V V. V V• - V V - .7 V. V V 3/25/86 V V V V 'V - VV •&•VS - - Specify that posts embedded ii concrete 14. Show 1/2" minimum clearance between top /s1al1 be pressure treated per UBC Std. No.. 25- plate of interior partitions and bottom chord of 12. Section 2516 (c). * trusses. (To ensure loading will be as - ' designed). FRAI4I* . • Show wall bracing. Every exterior wood Show double top plate with mininium48" ~96 u ) Fap)splice. Section 2517 (g) 2. d will and main cross partition shall be ' braced.at each endat least every 25 feet.of . 106 Show nailing will be-in compliance with length with 1.x 4 diagonal let-in braces or a le 25-Q. • .,P.' 't . equivalent. Section 2517 (g) 3. 2o - .•- 'H .. • 1I7. Show or note fir topsat the following o ecross bri or oc Floor gi.ng ..ng. locations per Section 2516 (f): ists to, and rafters 12" or more in depth shallbe,, • supported laterally by bridging at intervals not '• - a. in concealdspces of stud walls and exceeding 8 feet, unless both edges are held in . partitions,inciuding furred spaces, line., Sec.2506 (g). at the ceiling and floor levels and at - . 10 foot intezvals along the length of 9A.- Show blocking at ends and at supports of • the wall. • floor joists, and for rafters at exterior walls. Section 2517 (d)3. ' b. at all interconnections between concealed vertical and horizontal Show solid blocking at ridge line and at terior walls on trussed roofs. ' - ..' spaces such asoccur at soffits, drop .-ce'ilings and cove ceilings; : Section 2506 (g), Section 2517. (h). - • ,-• - ' • ' . c. in concealed spaces between stair ]Ø0. Show double joists. Floor joists shall be - stiingers at the top and bottom of the doubled under,bearing partitions running run and between.studs along and in parallel with the joists. Section 2517 (d) 5. . line with the run of stairs if the . walls under the stairs ar unfinished; Bearing partitions, perpendicular to and joists, shall not be offset from supporting , • girders, beams, walls or partitions, more than d. in openings' around vents, pipes, the depth of the joist. Section 2517 (d) 5.. - - ..ducts, chimneys, fireplaces and • - similar openings which afford a iIz. Show rafter ties. Rafter ties shall be passage for fire at ceiling and floor . spaced not more than 4 feet on center and be ' .' ,levels, with noncombustible • just above the ceiling joists, where rafters and materials. •• •• '-• A ' - ceiling joists are not parallel. Section 2517 (h) 4. , 19'8. Show stud size and spacing. Maximum - aüowable stud heights; Bearing wall: 2 x 4 and iO3.1 Show rafter purlin braces to be not less 2 x 6 max. 101; Non-bearing: 2 x 4 max. 141 , 2 than 45 degrees to the-horizontal. - - x 6 max. 20'. Table 25-R-3. Section 2517 (h) 5. • . • Studs supporting two floors,'a roof and ' 'eiling must be 3 x 4 or 2 x 6at 1611,o.c. - ' - ' .• * Table 25-R-3. . • • • •• • -' 8 • aa • - - -• - - 3/25/86 4' . : • • : -' -. i0. Note an A.I.T.C.4 Certificate of'Compliance iii. Show on the plans all structural fóor glued laminated wood members shall be given requirements developed in the structural to the building inspector prior to erection. calculations. V • Section 306 (f). V V V ]2. Columns and posts located on concrete or - Detail all post to beam and post .to masonry flàors or decks exposed to'the weather footing connections and reference the detail to or to water splash or in baseneñts and which the plan. Section 2516 .(m). : support permanent structures shall be supported by concrete piers or metal pedestals projecting V 42. Detail shear transfer connections, above floors unless approved wood of natural V 'including roof and floor diaphragms, to shear resistance to decay or treated wood is used.- walls. Section 2513. V V Section 2516(c) 4. '- V S V V • V VV V• 113 Specify nail size and spacing for all VS V 1,13: Individual concrete or masonry piers shall ear walls, floor-and roof diaphragms. project at least 8 inches above ekposed ground Indicate required blocking. Maintain maxim, 4 unless the columns or posts which they suport diaphragm dimension ratios. (Tables 25 I, J, K) are of approved wood of natural resistance to and Section 4713 (d). 2I @. 5.W /_ decay or treated wood is used. V V @2 Ixt — I}J( DJIOD V Section 2516 (c) 4. 14. Show 3" x 4" or 2" x 6" studs in first story of three story building. Table 25R-3. '. - 4. Show location of attic ccess with minimum V Yize V V 1,i5. Provide truss details and truss V 22" x 30". Section 3205. V V calculations for this project. V - V V ifS. Show draft separation for attic areas V V V between units in a duplex.. Section 2516 (f). if 6. Provide roof framing plan and floor V V framing plan. Section 302 (a).7. V V 16. Wood stud bearing walls, with studs at 24" V d.c., require 3 ea. 2x40r2 ea. 2x6or2 7. Provide framing sections through ' ea. 3 4 top plates if supporting either floor V .. members or roof trusses thAt are spaced more than 16" o.c. and:do not bear within 5" of the 5 supporting stud. Section 2517 (g) 2. V iy7t Specify plywood gradeand panel V• V Section 320 (a) 7. , V identification index. Table 25-N. V i8. Specify all header sizes for opening over V When roof pitch is less thafl V3:12, design V 4' wide. Section 2517 (g) 5. . V ridge as beam. Section2517 (h). . V 1)9. Provide calculations for main vertical d , •• V If foundation cripple wall studs are less V horizontal framing members and post footings. than 14" framing shall be solid blocking. Section 302 (a) 7. Section 2517 (g) 4 - 120 Provide calculations for lateral load, V , V . ' V sear panels,, shear transfer and related. V V 'Section 302 (9) 7.eec it till V • V 9 V V -. '•V V. V 3/25/86 " -- • - . .. - p e0. Cripple wall studs exceeding 4 feet in i,Lo. Show minimum 30" deep unobstructed working eight shallbe 3 inch by 4 inch or 2 inches by space in front of furnace. Section 505, UMC. 6 inches when supporting 2 stories. Section .2517 (g)4. . - . . 1 4. .911. Note on plans, clearances tobe per '.manufacturer's listing. Section 504, UMC. 411. Show plwood sheathing over exposed eaves, dr other weather exposed areas, is exterior ' : 1312. Furnace shall not be installed under any - grade. Section 2516(g) 3. . . , dtairway. Section 70bUMC. ..-'• '-• " U •rN'.,. . - I 912. Show a weep screed at the foundation plate . . (,9- Furnace shall not be installed in any - line on all exterior and stud walls to be bedroom, bathroom or inla closet or confined stuccoed. Section 4706 (e). - space with access only-through such room, unless specified as direct vent appliance, enclosed 13. Show corridor width to be minimum 36".' furnace or electric heating appliance. Section 3305 (b). . Section 704, UMC. tS'1 goOrh itD P CJNk1 til\) Y PL CflOf- ? cril ]4. Specify truss layout for 30" x 30" attic Show I.C.B.O. approval number for prefab access. . . . fireplace. - . . .. - 15. Ridges, hips, and valleys shall be at 1/5. Show access to the attic or underfloor least one size larger than supported rafters. : - furnace to be minimum 30 inches by 30 inches. Section 2517 (h) 3. . ' Section 708 & 709 UMC. 1,6. In open beam construction, provide strap 1L/6. Note that passageway to the attic furnace ties across the beams at the ridge support. . siall be unobstructed 'and have continuous solid Section 2501 (b). flooring not less than 24 inches wide. ' U Section 708, UMC. '". . . • J. MICAL - ' . . ]/7. Show permanent electrical outlet and All heating, ventilating, and cooling systems . lighting fixture controlled by a ss,itch for the and appliances shall comply with the Uniform attic 'furnace. Section 708, UMC. Mechanical Code. • . • ' 18. Show details to comply with Section 709' Show the size, location and type of all for furnace under the floor, or Section. 710 for 1{eating and cooling appliances or systems. roof or outside furnace. - 1p8. Show source of combustion air to furnace, 919. Note on plan: Gas vents and per Chapter 6, UMC. .- - - - noncombustible piping passing -through three floors or less shall be effectively draft . 49. Every dwelling unit shall be provided with - stopped at each' floor or ceiling. -' heating facilities capable of maintaining a room UBC, Section 1706 (a) 6. temperature of of 70 degrees F. at 3 feet above the' . - . . - • • floor in all habitable rooms. Show basis for compliance. UBC, Section 1211. - . - . • • ---a . • • -, . - . - - .' ... . ,- •__•p_- • . - 10 • - ' - .-- • - • S - • -. 3/25/86 • - -,- - -• . - • r - K. ELICAL (NATIONAL KURCTRICAL -()DE) 1%8. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet All wiring shall comply with the National - opening into bath or bedroom. Electrical Code UPC, Section 1309 -. 150 Show on the plan the amperage of the - B Provide adequate barrier to protect water e ectrical service, the location of the service - heater from vehicle damage. UPC, Section 1310. panel and the location of any sub-panels. 1,1. . Show location of all electrical - ., • Show I and P Valve on water heater and ?SOW receptacles. . route of discharge line to exterior. UPC,'Section 1007 (e). - ]2. Electrical receptacle locations and/or :1 - spacing is not adequate in 1]. Provide dryer vent to outside UMC, Section 1903 12. Note on the plan that hose bibbs and lawn sprinkler systems shall have approved backf low •, prevention devices. UPC, Section 1003. 153 Show at least one convenienceoutlet other outlets for laundry, etc., outdoors, in 13. Shower stall shall accommodate a 30" garages and basements.. NEC, Art. 210-52. circle and have a minimum floor area of • 1,024 sq. in. UPC, 909 (d). 154 Note convenience outlets in bathrooms, -o doors, and in garages and basements (other , M. NOISE INSULATION. (DUPLEX) . than for laundry and similar equipment) shall be . . . . GFI protected, NEC, Art. 210-8. 11 4. Show details of duplex common (party) Ialls and floor/ceiling assemblies to achieve a 155 Note electrical system ground to be Sound Transmission Class (STC) rating in walls p ovided per NEC, Art. 250-81. of 50decibles and on ImpaCt Insulation Class . S (IIC) rating on floor/ceiling of 50 decibles. L. PIJMBINO (UN.tYO14 PI.UMBINO (x)OE) , Title 25. 16. Show water heater size, type and location - 15. Show how penetrations of assemblies for * on plans. UPC, Section 1310. piping, electrical devices, recessed cabinets, . • . bathtubs, soffits, or heating ventilating, or 17. Show source for providing combustionair exhaust ducts shall be sealed, lined, or o fuel burning water heater. If wall opening - insulated to maintain required sound in an enclosure are used, at least one-half of transmission rating. Title 25. • the required opening area shall extend into the . . . . •••& • - upper twelve inches of the enclosure and, 1(/6. Provide insulation in walls and ceiling to one-half within the lower twelve inches. a/thieve STC of 50 between garage and living area UPC, Section 1307. • If garage use is not controlled by resident. - • - . • • Title 25. • . -, • - - . 11 . . . . S. • - - ,- 5-- . 3/25/86 1 N. ENERGY ()NSERVXrION: PLEASE READ State regulations (California Admin. Code) require that-the designsatisy on of the attached alternative energy packages or submit calculations. The law also requires that many mandatory conservationitems be satisfied. ( Show on the Title Sheet of the plans, the Eq),ired elements of the alternative energy package that was selected, and next to each element show how you are complying with each element; If calculations were used, provide similar data on the plans. (j) The plan sheet showing the required e ements of the selected energy package, and listing the design elements showing compliance with that selected package, must be signedby either the 'owner or a licensed professional i.e., architect, engineer or contractor. A design professional must note his/her state license 'number. Section 1403 of Title 20. (j) Show on the plans the III value for the w is,floors, ceiling and related areas. 'bo. Show double glazing as per Energy Design, 6n Glazing Schedule. It R'D () Show on the klan how shading requirements are satisfied. ii 17/2. The plans are not in compliance with the energy conservation compliance package selected or design'calculations provided. Show on plaits conformance as follows: 12'. 3/25/86 173 Specify on the building plans all of the -mandatory energy conservation requirements as listed 'on the enclosure titled, "Mandatory Energy Conservation Requirements". 1/4.' Show the sue, type, make, model and location of the spac heating (or"cooling) , system and provide heat loss calculations if the output BTU/Hr. exceeds 45,000. - 0. CARLSBAD S.P.D. & DUPLEX SOPPLENER! (179 Energy conservatioi design should be for Zone a 7 . 'See attached energy packages. 1,f6. Floor drains must have auto-prime (city policy). 7. Note exhaustfs cannot be ductlesstype (city policy). 1/8. New residential units must be pre-plumbed f'or future solar water heating. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). 179 Note "two 3/4" copper pipeimust be installed to the'most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). All piping for present or future solar water heating must be insulated when .in areas that are not heated or cooled by mechanical means (city policy). 1'1. Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry .. wall(s). . . Ro Show on the Title Sheet on the plans, the rmation required by the attached . Developmental Services Sheet 102683. Q183 All new residential buildings, including — aitions- require a soils report Please submit two copies * 'YL4 Heavy timber framing, minimum 6" x 10" ams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans (city policy). -. F • . . - . - 15. Please see additioial corrections, or remarks, on the following page. The City of Carlsbad has contracted with Esgil Corporation located at 9320 ,Chesapeake Drive, Suite 208, San Diego, California 92123; - . . . . ... . telephone number of 619/560-1468, to,perform the plan check for your project. If you have any questions regarding these plan check,items, please contact -°— -' . .• • . at Esgil Corporation. If you have any questions •. - - regarding-City Building permit procedures"' please contact Carter Darnell at the City of. Carlsbad, 1200 Elm Avenue, telephone 619/438-5525. . .. . .- Thank you. Enclosures: .- . . - . F •' - -F - . I 13 l' • . . - . - - . • - . -, 3/25/86 V. -V 4,. I - - - E FOLLOWING N= SPEcIF'Lfl MANBAIOR'l RUIR1ENTS SHOULD BE INCORPORAlED ON PLAN SUKErS,. OR COYLUXED WIfl JOB SPEcIYICAIION DOQJMENTS MANDATORY ENERGY CONSTRVAIION RFXUIRThENTS OF THES= OF CALIFORNIA All heating, ventilating, air conditioning,V a1d water heating equijment shall meet all of the - - requirements of the Appliance Efficiency Standards and shall be certified by the California Energy V Corrnnission. - V A two stage thermostat, which controls the supplementary heaton its second stage, shall be V provided for heat pumps.-- Thermostats shall be equipped with an automatic setback, which the building occupant can program to automatically set back the thermostat twice in 24 hours Equipment which requires preventive maintenance to maintain efficient operation shall be furnished with complete necessary maintenance information. - V (5) All gas-fired fan type central furnaces, gas-fired fan type wall furnaces and cooking appliances V shall be equipped with an intermittent ignition device. V V V (6) All fan systems exhausting air to the outside shall- be provided with bakdaft dampers. V All transverse duct, plenum, and fitting joints shall be sealed with pressure'sensitive tape or. -. mastic to prevent air loss and shall be insulated to conform to the provisions .of Section 1005 of V -, the IJMC, 1982 Edition. V V V A vapor barrier is required in climate zone 1, 14,-and 16. All manufactured windows and sliding glass doorsshall meet the 1972 ANSI airinfiltration V standards and shall be certified and labeled. All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped. V V (U) Storage type water heaters and storage and backup tanks for solar systems shall be externally V V - - wrapped with R-12 insulation or greater. (12) The five feet of pipe closest to the water heater, if outside conditioned space, shall be insulated with a minimum of R-3. 'Steam and steam condensation return piping and recirculating hot water V piping outside the building envelope shall be insulated in accordance with 120-1406(d). V V (13) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of V V V y not less than 25 lumens per watt. (14) Showerheads and faucets shall be equipped with flowrestrictors as outlined .-in the appliance V V efficiency standards and shall be certified to the-Energy Commission.' V (15) Masonry and factory-builtfireplaces ori exterior walls, shall be equipped with tight-fitting V V - closeable metal or glass doors covering the entire opening of the firebox; a combustion air intake - V - equipped-with a readily accessible, operable, and tight fitting damper to draw air from the outside V V of the building; and a tight fitting flue damper, with a readily accessible cottrol. V V (16) Insulation used shall comply with California Quality Standards. - (17) The insulation installer shall post.a signed certificate ... Section. 276.. Insulation Certificate V (All Occupancies). After installing insulation, the installer shall post in a conspicuous.locatiän V in the building a certificate signed by the installer and the builder stating that the installation - V V - V conforms the requirements of Title 24, Part z; Chapter 2-53, and that the materials installed V conformwith the requirements of Title 20, Chapter 2, Subchapter 4, Article 3.-'The certificate - V V shall state the manufacturer's name an&material identification, the installed-"R"value,-and (in c. V applications of loose fill insulation) the minimum installed weight per square foot consistent with the manufacturer's labeled density for the desired "R" value. (18) For infiltration control all openings and penetrations must be caulked and sealed, such as around V windows, at sole plates, and openings for utility pipes and wires Form EH 3/5/86 4" brick Concrete block 90 pcf Concrete block 140 pcf Climate Zone Slab Floor Z exposed one side block density, grouted - block density, solid grouted - 4" 6" 4" 6" 15 21 18 17 14 • 13 20 28 - 24 22 18 . 18 7 25 35 30 - 28- -, 23 22 - E - -I -- - I I Table 17 Notes for Tables 'l through 16 LEGEND NR - Not required, N/A -.Not- applicable, REQ - Required, 'MIN - Minimum efficiencies required by Section 25306. of the + - regulation. NO " Heating system type not allowed, YES - Heating system type allowed.. - 3. Whenever an attic is required, it mustcover at-,least three-quarters (3/4) of the ceiling area over conditioned apace ad be vented. -- Inalternative component packages which require thermal man (other than-Package A), the specified percentage of mass must be directly exposed to the conditioned space. To determine the floor area-directly exposed to the conditioned space. To determine the floor area, count only théfirst floor in conditioned areas. Uncar-peted first floor areas, such as linoleum or tiled entry ways, kitchens, bathrooms, and' utility closets may all be counted towards this requirement. - Thermal mass required for Packages E,1,2,3 and 4 must be- either - equivalent to a slab floor covering one-fourth (25 percent) of the floor area with a thickness of at least 2 inches anda volumetric heat capacity of 28 Btu/ft3 °F (see below for surface area of materials examples) or provide the minimum total mass capacity listed-in Table 17 of Appendix A (use the Point System to calculate the mass for other materials). Date1jp7 CITY OF CARLSBAD ' Prepared by •r BldDépt MiI ArEu VALUATION AND PtAN CHECK FEE 0 Esgil PLAN CHECK .NO._- BUILDING ADDRESS -_Ij i ie r AuE APPLICANT/CONTACT 5PJ VwKY. PHONE NO.________________ BUILDING OCCUPANCY - (-3 /h'-I DESIGNER PHONE___________ TYPE OF CONSTRUCTION V—M CONTRACTOR PHONE___________ BUILDING PORTION BUILDING AREA 'VALUATION MULTIPLIER VALUE 4 f Low(, Ae ' 44 - 4Lh)th Air ConditioninE Commercial '@ ' Residential Res. or, Comm. Fire Sprinklers ' Total Value Fee Adjusted To Reflect 0 Energy Regulations (Fee x 1.1) 0 Handicapped Regulations,.-.(Fee x 1.065) ,1 Building Permit Fee $ S 2ii.L7) Plan Check Fee $. ' S ) 34 2_ COMMENTSL 4 8/4/82 ENVIRONMEN ADDITIONAL OK TO ISSUE:' DATE: PLAN CHECK ADDRESS 13/ DATE PLANNING s ZONE: TYPE OF PROJECT AND USE:____ SCHOOL DISTRICT: SAN DIEGUITO ENCINITAS - CARLSBAD SAN MARCOS po -- SETBACKS: FRONT 6en YCp# REAR DISCRETIONARY ACTIONS:_____________________________________________________________ REDEVELOPMENT PERMIT REQUIRED:J LANDSCAPE PLAN COMMENTS:___________________________________________________________ ENGINEERING LEGAL DESCRIPTION VERIFIED?_1. APN CHECKED?_,. PARK-IN-LIEU QUADRANT: , FEE PER UNIT:r TOTAL FEE: — P.F.F.:JJ/_-_ TRAFFIC IMPACT FEE PER UNIT: TOTAL FEE:.------- FACILITIES MGMT. FEE: BRIDGE & THOROUGHFARE 4 j-A- IMPROVEMENTS:__________________________ FIELD CHECK DATE & INITIALS: -- RIGHT-OF-WAY:. DRIVEWAY: IJ 'EASEMENTS: E.D.U.: SEWER: LATERAL:_________ INDUSTRIAL WASTE PERMIT: DRAINAGE: A) GRADING PERMIT:_/- ____GRADING COMPLETION CERTIFIED:________ ADDITIONAL COMMENTS:____________________________________ OK TO ISSUE: __ DPD2:DPD6:07/17/86