Loading...
HomeMy WebLinkAbout1710 CATALPA RD; ; CB140210; Permit03-12-2014 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: Project Title: City of Carlsbad 1635 Faraday Av Carlsbad.CA 92008 Cogeneration Permit Permit No:CB1402lO Building Inspection Request Line (760) 602-2725 1710CATALPARD CBAD COGEN Sub Type: PHOTO Status: ISSUED 2155110400 Lot#: 0 Applied: 01/28/2014 $6,400.00 Constuction Type: NEW Entered By: RMA Reference #: Plan Approved: 03/12/2014 Issued: 03/12/2014 Inspect Area: Plan Check #: BRUNTON RES- PHOTOVOLTAIC SYST 16 ROOF MOUNTED MODULES, REPLACE EXIST 100 AMP PANEL W/ NEW 125 AMP PANEL- SAME LOCATION Applicant: PLUMBLINE DESIGN 4615 WINNEBAGO AV SAN DIEGO CA 92117 858273-5222 Owner: BRUNTON TRUST 05-17-00 1710CATALPA RD CARLSBADCA 92011 Building Permit $97.47 PLUMBING TOTAL $0.00 Add'l Building Permit Fee $0.00 ELECTRICAL TOTAL $0.00 Plan Check $68.23 MECHANICAL TOTAL $0.00 Add'l Plan Check Fee $81.77 Additional Fees $0.00 Plan Check Discount Strong Motion Fee Green Bldg Stands (SB1473) Fee $0.00 $1.00 $1.00 TOTAL PERMIT FEES $249.47 Total Fees: $249.47 Total Payments To Date: $249.47 Balance Due: $0.00 Inspector: CcM^<, FINAL APPROVAL Date: 4 Clearance: NOTICE: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions," You have 90 days from the date this pemiit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required infomiation witti the City Manager for processing in accordance with Carisbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously othenwise expired. THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: nPLANNING OENGINEERING •BUILDING DFIRE nHEALTH ElHAZMAT/APCD Plan Check No (1^/^ / Q ^0p ^ CITY OF CARLSBAD Building Permit Appiication 1635 Faraday Ave., Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 email: building@carlsbadca.gov www. ca risbadca. gov Est. Value Plan Ok. Deposit Date SWPPP JOBADpRpS CT/PRO. I7 n r,^-rA\-PA^ IJECT# ^~ L0T# I PHASE # I # OF UNITS j # BEDROOMS iWTHROOr^Js SUITE*/SPACE«/UNIT* TENANT BUSINESS NAME CONSTR. TYPE OCCGROUP DESCRIPTION OF WORK: /nclude Square Feet of Affected Areafs; EXISTING USE PROPOSED USE ^ GARAGE (SF) PATIOS (SF^-S DECKS (SR^ FIREPLACE AIR CONDITIONING FIRE SPRINKLERS . ^^^^ ^^^.^-'^^ VEINS' NO| 1 YE^PCINO 1 1 YESQN^^J APPLICAHT NAME (Primary Contact) ^^^^^^^^^^^ ^ i^^^^-APPLiCAI(pfiAIVIE (Secondary Cordact) ADDRESS , . ADWfESS • CITY" ' " .STATE* ^ ZIP CITY J / STATE ZIP ^ ^ FAX • ' PHONE FAX PROPERTYOWNERNAME ^^^J^., CONTRACZePyBUS.NAME / / ^-T—> ADDRESS , ' ADDRESS CITY • ' ' 'STATE ZIP y^D AOZ FAX . _ . ElJlAIL " • " ~ ARCH/DESIGNER NAME & ADDREgS STATE LIC. # STATE Ll<.# CLASS CITY BUS. LIC.# j (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permitto file a signed statement that h( " ... - . _ _ ... .. .. Business and Professions Code) or that he is exempt thert civil penalty of not more than five hundred dollars ($500)), applicantfor such permitto file a signed statement that he is licensed pursuant to the provisions ofthe Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 ofthe Business and Professions Code) or that he is exempt therefrom, and the basis forthe alleged exemption. Any violation of Section 7031.5 by any applicantfor a permit subjects the applicantlo a Worl<ers' Compensation Declaration: thereby affinn under penalty of peijury one of the foiiowing deciarations: • I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. ,,)^3'l have and will maintain worjfeijs' copMUBation, as reguijEiLti^ Section 3^of the Labor Code, for the performanre of the work for whch this permit is issued^^My.workers' compensation insurance earrier and policy number are: Insurance Co. L^^^r •jy/'/fc*^ .^'/•^fc^. ' Policy No. C-£_/Expiration Date This section need not be compieted if the permit is for one hundred dollars ($100) or less. I I I Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not empioy any person in any manner so as to become subject to the Workers' Compensation Laws of California. WARNING: Failure to secure worke|»Vy>MpiiinoiitlBn aeMariiflgjs unlawful, and shall subject an employerto criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation,JamjBlw liMluVMlj JS^ CONTRACTOR SIGNATURS I ^hnr ryrii-, If.'"-"-* and attomey's fees. ^ QAGENT DATE OWNER-BUI OER OECIARATI / hereby affinn that i am exempt from Contractor's License Law for the foiiowing reason: I [ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or oflered for sale. If, however, the building or improvement is sold within one year of compietion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I I I, as owner of the properfy, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). I I I am exempt under Section Business and Professions Code for this reason: 1, i personally plan to provide the major labor and materials for construction of the proposed property improvement. QYes 1 iNo 2.1 (have / have not) signed an appiication for a building permit for the proposed work. 3.1 have contracted with the following person (firm) lo provide the proposed constmction (include name address / phone / contractors' license number): 4.1 plan to provide portions of the work, but i have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number): 5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work): ygfpROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or future buikiing occupant required to submit a business plan, acutely hazanjous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Yes No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Yes No Is the fxility to be constructed within 1,000 feet of the outer boundary of a school site? Yes No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm ttiat ttiere is a constmction lending agency for ttie performance of ttie wori< this pemiit is issued (Sec. 3097 (i) Civil Code), Lender's Name Lender's Address PLICANT CERTIFICATION I certify that I have read the applkatkin and state thatthe above infbmiation is conect and that the infonnation on the plans is accuiate. I agree to comply witti all Cify oidinances and State laws relating to buildng construction. I hereby authorize representative ofthe Cify of Carlsbad to enter upon the above mentioned properfy Ibr inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST Aa LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA peimit is required for excavations over 5'0' deep and demolition or constmction of staictures over 3 stories in height. EXPIRATION: Every penmit issued by the Building Oflicial under the provisbns ofthis Code shall expire by limitatbn and become null and void if the building or WDI1< authorized by such pemnit is not commenced within 180 days from the date of such permit or if the building^ r vwk ai*orized by sudiDemiit is suspended or abandoned at any time after the work is commenoed for a period of 180 days (Sectbn 106.4.4 Unifonn BuikJing Code). ^APPLICANT'S SIGNATURE ///I V ^jC^ DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (780) 602-8560, Email buildinq(5)carlsbadca.qov or Mail ttie completed fomi to City of Carisbad, Building Division 1835 Faraday Avenue, Carlsbad, Califomia 92008. C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICKUP: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAILTO: CONTACT (Listed above) OCCUPANT (Listed above) CONTRACTOR (On Pg. 1) MAIL/FAXTOOTHER: ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION ASSOCIATED CB# NO CHANGE IN USE / NO CONSTRUCTION CHANGE OF USE / NO CONSTRUCTION >gf APPLICANT'S SIGNATURE DATE Inspection List Permit*: CB140210 Type: COGEN PHOTO Date Inspection Item 03/19/2014 33 Service Change/Upgrade 03/19/2014 35 Photo Voltaic (PV) 03/19/2014 39 Final Electrical 03/19/2014 39 Final Electrical Inspector Act MC AP MC MC AP Rl Fl BRUNTON RES- PHOTOVOLTAIC SYST 16 ROOF MOUNTED MODULES, REPLAC Comments MAXIMUM 125 AMP MAIN BREAKER REQUIRED AT ALL TIMES. BRUNTON RES CALLED IN TO KIMYA Wednesday, March 19, 2014 Page 1 of 1 EsGil Corporation In (Partnersfiip •witfi government for (BuiCrCing Safety DATE: 02/25/2014 • APPLICANT • JURIS. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLANCHECKNO.: 14-0210 SET: II PROJECTADDRESS: 1710 Catalpa Rd. PROJECT NAME: Burton 4000 Watt Solar Photovoltaic System XI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's codes when minor deficiencies identified below are resolved and checked by building department staff. I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. I I The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. I I The applicant's copy of the check list is enclosed for the jurisdiction to fonA/ard to the applicant contact person. I I The applicant's copy of the check list has been sent to: Esgil Corporation staff did not advise the applicant that the pian check has been completed. I I Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Telephone #: Date contacted: (by: ) Fax #: Mail Telephone Fax In Person E-mail: • REMARKS: By: John Le Vey Enclosures: EsGil Corporation • GA • EJ • PC 02/25/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576 EsGil Corporation In (partnersfiip witfi government for (BuiCcCing Safety DATE: 02/05/2014 • APPLICANT /gf'jURIS. JURISDICTION: Carlsbad • PLANREVIEWER • FILE PLANCHECKNO.: 14-0210 SET: I PROJECTADDRESS: 1710 Catalpa Rd. PROJECT NAME: Burton 4000 Watt Solar Photovoltaic System I I The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. I I The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff. • The plans transmitted herewith have significant deficiencies identified on the enclosed check iist and should be corrected and resubmitted for a complete recheck. XI The check list transmitted herewith is for your information. The plans are being held at Esgil Corporation until corrected plans are submitted for recheck. • The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person. The applicant's copy of the check list has been sent to: I I Esgil Corporation staff did not advise the applicant that the plan check has been completed. IXI Esgil Corporation staff did advise the applicant that the plan check has been completed. Person contacted: Alec J Zier Telephone #: 619-884-9229 patecontacted:7(S (by:^^^ Fax #: v^Mail Telephone Fax In Person E-mail: azier@san.rr.com • REMARKS: By: John Le Vey Enclosures: EsGil Corporation • GA • EJ • PC 01/30/2014 9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858)560-1468 • Fax (858) 560-1576 Carlsbad 14-0210 02/05/2014 GENERAL PLAN CORRECTION LIST JURISDICTION: Carlsbad PLANCHECKNO.: 14-0210 PROJECTADDRESS: 1710 Catalpa Rd. DATE PLAN RECEIVED BY ESGIL CORPORATION: 01/30/2014 DATE REVIEW COMPLETED: 02/05/2014 REVIEWED BY: John Le Vey FOREWORD (PLEASE READ): This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and disabled access. This plan review is based on regulations enforced by the Building Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The following items listed need clarification, modification or change. All items must be satisfied before the plans will be in conformance with the cited codes and regulations. The approval of the plans does not permit the violation of any state, county or city law. • Please make all corrections and submit two new complete sets of prints to: ESGIL CORPORATION. • To facilitate recheclcing, please identify, next to each item, the sheet of the plans upon which each correction on this sheet has been made and return this sheet with the revised plans. • Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located on the plans. Have changes been made not resulting from this list? • Yes • No Carlsbad 14-0210 02/05/2014 ELECTRICAL and ENERGY COMMENTS PLAN REVIEWER: John Le Vey ELECTRICAL (2010 CALIFORNIA ELECTRICAL CODE) Generally the plans are incomplete and a thorough plan check can not be done, the following list is a general list only and corrections may follow. Please make all corrections, as requested in the correction list. Submit FOUR new complete sets of plans for commercial/industrial projects (THREE sets of plans for residential projects). For expeditious processing, corrected sets can be submitted in one of two ways: 1. Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760) 602-2700. The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments. 2. Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments. NOTE: Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1. Please provide a statement on the Title Sheet of the plans to show compliance with the current Codes. The following are the correct current Codes: a) The 2013 edition of the California Building Code (CBC) adopts the 2012 International Building Code (IBC) and the 2012 California Amendments. b) The 2013 edition of the California Electrical Code (CEC) adopts the 2011 National Electrical Code (NEC) and the 2012 California Amendments. 2. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code. 5536.1). 3. Please show compliance for the required (dc) Arc Fault protection per section 690.11. 4. Please provide the manufacture specification sheet for the Inverter 5. Please provide a sample of the required labels and signs per CEC690 on the plans 6. Please provide the listed racking system with the plans 7. Please clarify the application states that a service upgrade will occur, however on the single line it is showing an existing 175 amp service, and on sheet AO.O shows an existing 150 amp service, then the application states a 150 amp upgrade, clarify. Show the correct existing and the proposed. 8. Provide a statement on the plans "The PV connection in the panel board shall be positioned at the opposite (load) end from the input feeder location or main circuit location. CEC 690.64(B)(7)". Carlsbad 14-0210 02/05/2014 9. Please add the following note to the plans: "Roof coverings shall be designed, installed and maintained in accordance with this code and the approved manufacturer's instructions such that the roof covering shall serve to protect the building or structure. CBC 1503." 10. Provide a grounding electrode system per CEC250.50 and grounding electrode conductor sized per Table 250.66, minimum #8 copper, at the structure on which the PV System and/or inverter is installed. See CEC 690.47. The grounding electrode conductor shall be without a splice. CEC 250.64 (C). Please show the GEC at the electrical service. 11. Please clarify that the array will be 3 inches off the roof as stated on sheet m-100. 12. Show the location of all roof mounted equipment including the PV modules, junction box(s), combiner box(s), disconnect(s), and Inverter(s). 13. Show how the conductors will be run from the array to the sub-panel or main panel. Call out the type of conductor/cable to be used and show how the conductors will be protected, i.e. type of conduit to be used. You are calling out conduit only on the plans. Note: If you have any questions regarding this Electrical and Energy plan review list please contact John Le Vey at (858) 560-1468. To speed the review process, note on this list (or a copy) where the corrected items have been addressed on the plans. Carlsbad 14-0210 02/05/2014 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION: Carlsbad PLANCHECKNO.: 14-0210 PREPARED BY: John Le Vey DATE: 02/05/2014 BUILDING ADDRESS: 1710 Catalpa Rd. BUILDING OCCUPANCY: TYPE OF CONSTRUCTION: BUILDING PORTION AREA ( Sq. FL) Valuation Multiplier Reg. Mod. VALUE ($) PV system Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code cb By Ordinance Bldg. Permit Fee by Ordinance • Plan Ciieck l=ee by Ordinance Type of Review. • Complete Review/ • Repetitive Fee Based on fiourly rate • Other [7]—youdy EsGfl Fee $161.25 • Structural Only 1.5 $86.00 Hrs. $129.00 Comments: 1.5 hour plan review. Sheet 1 of 1 macvalue.doc + CITY OF CARLSBAD PLANNING DIVISION BUILDING PLAN CHECK APPROVAL P-29 Development Services Planning Division 1635 Faraday Avenue (760) 602-4610 wwM/.carlsbadca.eov DATE: 1-28-14 PROJECTNAME: PROJECTID: PLAN CHECK NO: CB 14-0210 SET#: 1 ADDRESS: 1710 Catalpa Rd APN: 215-511-04 ^ This plan check review is complete and has been APPROVED by the Planning Division. By: Chris Sexton A Final Inspection by the Planning Division is required • Yes No Vou may also tiave corrections from one or more of ttie divisions listed below. Approval from ttiese divisions may be required prior to the issuance of a buildingpermit Resubmitted plans stiould include corrections from all divisions. • This plan check review is NOT COMPLETE. Items missing or incorrect are listed on the attached checklist. Please resubmit amended plans as required. Plan Check APPROVAL has been sent to: azier@san.rr.com For questions or clarifications on the attached checklist please contact the following reviewer as marked: PLANNING 760-602-4610 ENGINEERING 760-602-2750 FIRE PREVENTION 760-602-4665 X Chris Sexton 760-602-4624 Chrls.Sexton@carlsbadca.fiov 1 1 Kathleen Lawrence 760-602-2741 Kathleen.Lawrence@carlsbadca.gov Greg Ryan 760-602-4663 Grefiorv.Rvan@carlsbadca.fiov 1 1 Gina Ruiz 760-602-4675 Glna.Rulz@carlsbadca.fiov 1 1 Linda Ontiveros 760-602-2773 Llnda.Ontiveros@carlsbadca.fiov Q Cindy Wong 760-602-4662 Cvnthia.Wong@carlsbadca.fiov • • 1 1 Dominic Fieri 760-602-4664 Dominic.Fierl@carlsbadca.gov Remarks: SDGF A (^Sempra Energy mwy" wanteaoaie: On Inspection ELECTRIC UNDERGROUND METER & SERVICE LOCATION Customer Copy Service Type: UG Rewire (no trenching) Projecl No: 452748 Job No: 010 Proiect Title: BRUNTON RESIDENCE (SOT) Projecl Address: 1710 CATALPA RD Projed Clly: CARLSBAD Conlael: KEN LORD Customer Phone t. Contaci Phone #: 760-402-9918 • Traffic Conrol Pertnil Required. Excavalion/Encroachment Pennits Required By Customer Sennce Alachmeni Point and/or Meier Location: Install new 125-amp meter panel at existing location over existing conduit and service conductors. Customer assumes responsibility for existing SIDA condition. If SIDA conductors cannot be reconnected for any reason, customer is advised they will not be reconnected until they can trench and replace the SIDA conductors with 2-inch conduit from the panel to the source. Call SDG&E Service Coordinator Wendy at 760476- 5611 to schedule a morning disconnect with an afternoon reconnect provided that the City/County releases inspection to SDG&E by 2:00 PM on the same day the crew is scheduled. To avoid delays with reconnection, your permit should read (Customer Outage Involved). • SDG&E Appication Required - Calt 1-800-411-7343 Municipal Inspectbn Requited By City of Carisbad Mitar haight - 4V nia (SV mia. fcr imMph melw iratriWon) - max. Fnm finish grade to ctnleiline of mtter base. Meters are required to be Midily acoessitile 24 hows per day. Malara must be localed ii a sale aiea Irae of any potentiaUy hazardous or dangenus condition. Piovide S-lt X 3-tl Minimum dear and level worlgng space in front of meter. Where meter mem is proposed, contact me planner al the nearest SOGtE office. Meier bases and meter senaoe disconnects musl be located at w immediately adjacent lo each other and be identified wth ad(t«ss and unt number i serves. PROCEDURE FOR INSTALLATION 1. PHONE DIG ALERT 1-800-227-2600 AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTLITES. 2. Phone SDG&E al 760-476-5611 for the following: • 3 working days prior to trenching lo anrange pre-meet with inspector and initate trenching process. • Aflerexcavationottiencti.instaHalionofoonduiandsefvlceentanceequipnientalmeterlocatlon. CALL FOR INSPECTION. Do not cover conduit without mspeclor's written approval to backiU. • When trench is backflled and compacted. CALL FOR INSPECTION. • If servkx enfance equipment is installed ater backlll. CAU FOR INSPECTION OF THE EQU IPMENT. 3. Meter cannot be sel untU inspector has approved Installaton, Including service equipment, and receipt of Power Source: 1116-645 Slruclure Number: EXISTING 3312 HANDHOLE Joinl Trench with: Handhob Installed by: Standards Page Ift Handhole Lid Shall Read: Conduit Instated by: Conduit Size: Seivice Panel Raling: 125 NumberfSize of Main Switch: 1/125 Vollage: 120/240 # of Wires: 3 Phase: Single unities Maximum Conribution to Fault Current 10000 Amps Metering: Self-Contained Meter aips: 4 Temp Service Charge Due on Firsl Bill $ TB. 1127-E6 Customer Type: Residential Jale Prepared: 03/11/2014 t N ' XST: MIMOSA Dl SCONNECT/RECONNECT PROJECT# 452748 NEW 12S-AMP Additional informalion: • Rigttt-of-way Required Assessor's Parcel Number: Please call your Service Coordinator Wendy Jensen at 760-476-5611 with questions about application, inspection, construction instaUation and to schedule a crew. City/County inspection will have to be received prior to 2:00 p.m. on the same day as the disconnect to allow SOG&E crew enough time for reconnection of service on the same day. :i SOC^ encoutlfers hazardcus or bxic malenal whi'e pariomiinig construction af >our pro|acl SDC&E witl halt work irnrnettaMty and it wtU ti9 your responsibihty to nmove and'or ctoen up all hazardous or toxic rriatenai pnor lo SOCAE continuing construction SOG&E shalt hava no itabifaty or ctu^aiion whaiSMver to ci«an up iwnova or ranwdMit* any hazaidou« or iomc mxtfiait <tacov««d dunng tha cousa of ovnktrucion unltuti«throuQh m^gnmt oi SOG&E Cuasmw-owned Polities lorecewetecrcal servcearfl sut^ifjct (o all afipticaClfl local and iftteiy Calitsrnia inspection authority rwjmrements Buildmg addrass ancVor malar basa mu&t be posiad prior to mater sal m^rmaiim on ttns shuet is void atar (6) months item dala Kaap INs rtoitca wih t:>uiktnij parmit All insta'laborB parformad under ttts or oer must meet SOG&E staiiijanls ijoieas a wnien oevialiofi has Deen app/o.'>i<l Planner: AMY P MCBROOM Telephone: 760-476-5610