Loading...
HomeMy WebLinkAbout1710 Yada Pl; ; CBRA2018-0057; PermitPrint Date: 11/05/2019 Job Address: 1710 Yada Pl Permit (City of Carlsbad Permit No: CBRA2018-0057 Permit Type: BLDG-Associated Permit Resi Work Class: Parcel No: 1562206100 Lot#: Single Family Detached 8 Status: Applied: Closed -Finaled 03/13/2018 04/17/2019 Valuation: Occupancy Group: # Dwelling Units: Bedrooms: Project Title: $484,362.26 Reference#: DEV02058 1 4.00 YADA FARM Construction Type: VB Bathrooms: 3.50 Orig. Plan Check#: PC2017-0048 Plan Check#: Issued: Permit Fina led: Inspector: MColl Final Inspection: 11/5/2019 1:34:23PM Description: YADA FARM: PHASE 1 // LOT 8 // PLAN 2C // 3,004 SF// 174 SF PATIO// 507 SF GARAGE// 49 SF PORCH Applicant: MARY NETTLES 5927 Priestly Dr, 110 Carlsbad, CA 92008-8800 760-918-2829 BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) Owner: TRUST VADA FAMILY TRUST 03-12-90 1835 Buena Vista Way CARLSBAD,CA 92008 ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PARK IN-LIEU FEES SF DETACHED & DUPLEX: NW PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD 581473 GREEN BUILDING STATE STANDARDS FEE SDCWA SYSTEM CAPACITY CHARGE 5/8" Displacement SEWER CONNECTION FEE (General Capacity all areas) STRONG MOTION-RESIDENTIAL SWPPP INSPECTION FEE TIER 1-Medium BLDG SWPPP PLAN REVIEW FEE TIER 1-MEDIUM TRAFFIC IMPACT Residential Single Fam. Outside CFD WATER METER FEE 1" Displacement (P) WATER SERVICE CONNECTION FEE 5/8" DISPLACEMENT (P) WATER TREATMENT CAPACITY CHARGE 5/8" Displacement Total Fees: $43,103.73 Total Payments To Date: $43,103.73 Contractor: CALIFORNIA WEST CONSTRUCTION INC 5927 Priestly Dr, 110 Carlsbad, CA 92008-8800 760-918-6768 Balance Due: $0.00 $1,992.75 $1,283.33 $66.00 $170.00 $92.00 $7,649.00 $182.00 $16,952.68 $20.00 $5,267.00 $960.00 $62.97 $246.00 $56.00 $3,390.00 $282.00 $4,286.00 $146.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov \. PERMIT INSPECTION HISTORY REPORT (CBRA2018-0057) ' '> ,' Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision: Status: Closed -Finaled Expiration Date: 04/13/2020 Address: IVR Number: 10093 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 1110512019 1110512019 BLDG-Final Inspection 109799-2019 Checklist Item BLDG-Building Deficiency BLDG-Plumbing Final BLDG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final BLDG-Fire Final 107959-2019 Checklist Item FIRE-Building Final November 05, 2019 Passed COMMENTS Scheduled COMMENTS Michael Collins Felix Salcedo TRUST YADA FAMILY TRUST 03-12-90 1710 Yada Pl Carlsbad, CA 92008 Reinspection Complete Complete Passed Yes Yes Yes Yes Yes Incomplete Passed No Page 3 of 3 PERMIT INSPECTION HISTORY REPORT (CBRA2018-0057) Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision: Status: Closed -Finaled Expiration Date: 04/13/2020 Address: IVR Number: 10093 Scheduled Date Actual Start Date Inspection Type Inspection No. BLDG-34 Rough Electrical 099838-2019 Checklist Item BLDG-Building Deficiency BLDG-44 Rough/Oucts/Dampe rs 099839-2019 Checklist Item BLDG-Building Deficiency 0810712019 0810712019 BLDG-16 Insulation 099978-2019 Checklist Item BLDG-Building Deficiency 08/0812019 0810812019 BLDG-16 Insulation 100333-2019 Checklist Item BLDG-Building Deficiency BLDG-18 Exterior 100210-2019 Lath/Drywall Checklist Item BLDG-Building Deficiency 08116/2019 0811612019 BLDG-17 Interior Lath/Drywall 101065-2019 Checklist Item BLDG-Building Deficiency BLDG-23 Gas/TesURepairs 101064-2019 Checklist Item BLDG•Building Deficiency 1011612019 10116/2019 BLDG-Electric Meter 107609-2019 Release November 05, 2019 Checklist Item BLDG•Building Deficiency BLDG-Gas Meter Release 107610-2019 Checklist Item BLDG•Building Deficiency Inspection Status Primary Inspector Passed COMMENTS Passed COMMENTS Cancelled COMMENTS Passed COMMENTS Cancelled COMMENTS Wrong code Passed COMMENTS Passed COMMENTS Cancelled COMMENTS Failed COMMENTS Michael Collins Michael Collins Michael Collins Michael Collins Michael Collins Peter Dreibelbis Peter Dreibelbis Peter Dreibelbis Peter Dreibelbis TRUST YADA FAMILY TRUST 03-12-90 1710 Yada Pl Carlsbad, CA 92008 Reinspection Passed Yes Passed Yes Reinspect ion Passed No Passed Yes Reinspection Passed No Passed Yes Passed Yes Reinspection Passed No Reinspection Passed No Complete Complete Complete Complete Complete Complete Complete Complete Complete Complete Page 2 of 3 PERMIT INSPECTION HISTORY REPORT (CBRA2018-0057) Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision: Status: Closed -Finaled Expiration Date: 04/13/2020 Address: IVR Number: 10093 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 05/02/2019 05/02/2019 BLDG-21 Underground/Underf loor Plumbing 090637-2019 Checklist Item BLDG-Building Deficiency 05/10/2019 05/10/2019 BLDG-11 Foundation/Ftg/Pier s (Rebar) 091518-2019 Checklist Item BLDG-Building Deficiency 06/25/2019 06/25/2019 BLDG-15 095618-2019 Roof/ReRoof (Patio) Checklist Item BLDG-Building Deficiency 07/12/2019 07/12/2019 BLDG-13 Shear Panels/HD (ok to wrap) 097211-2019 Checklist Item BLDG-Building Deficiency 07/15/2019 07/15/2019 BLDG-13 Shear Panels/HD (ok to wrap) 097534-2019 Checklist Item BLDG-Building Deficiency 08/01/2019 08/01/2019 BLDG-14 Frame/Steel/Bolting/ Welding (Decks) 099382-2019 Checklist Item BLDG-Building Deficiency 08/02/2019 08102/2019 BLDG-24 Rough/Topout 099718-2019 Checklist Item BLDG-Building Deficiency 08/05/2019 08/05/2019 BLDG-14 099723-2019 November 05, 2019 Frame/Steel/Bolting/ Welding (Decks) Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Passed COMMENTS Passed COMMENTS Passed COMMENTS Passed COMMENTS Failed COMMENTS Not ready Cancelled COMMENTS Cancelled Passed COMMENTS Top out only Passed COMMENTS Cancelled Tim Frazee Tim Frazee Paul Burnette Paul Burnette Michael Collins Michael Collins Michael Collins Michael Collins TRUST YADA FAMILY TRUST 03-12-90 1710 Vada Pl Carlsbad, CA 92008 Reinspection Complete Passed Yes Passed Yes Passed Yes Passed Yes Reinspection Passed No Reinspection Passed No Passed Yes Passed No Yes Complete Complete Complete Complete Complete Complete Complete Complete Page 1 of 3 ,~~-w CIT Y OF CARLSBAD Building Division INSPECTION . RECORD i;il--'!USPECTION RECORD CARD WITH APPROVED ANS MUST BE KEPT ON THE JOB ------- CBRA2018-0057 1710YADA PL YADA FARM: PHASE 1 // LOT 8 // PLAN 2C // 3.004 SF II 174 SF PATIO// 007 SF GARAGE /149 SF PORCH ~ALL BEFORE 3;00 pm FOR NEXT WORK DAY INSPECTION DEV02058 1562206100 4/18/2018 0 FOR BUILDING INSPECTION CALL: 760-602-2725 OR GO TO: www.Carlsbadca.gov/Building AND CLIClf ON,.. "Request Inspection" • DATE: 4--2 -\ PC2017-0048 CBRA2018-0057 If .. YES" is checked below that Division's approval is required rior to re uestin a Final Building Inspection. If you have any questions please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to 760-602-8560, email to !:!_Id ins ections_(§;l~c1_rls!)ad_c;a.g9__v or bring in a COPY of this card to: 1635 Faraday Ave .. Carlsbad. IF MARKED 'YES·, IT IS REQUIRED PRIOR TO ANY CONSTRUCTION STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours IF MARKED 'YES·, APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING Fire Prevention 760-602-4660 Allow 48 hours Planning/landscape 760-944-8463 Allow 48 hours CM&I (Engineering Inspections) 760-438-3891 Call before 2 pm Type of Inspection CODE# BUILDING CODE # ELECTRICAL Ins or Notes Date COPY OF CARD REQUIRED Inspector #31 D ELECTRIC UNDERGROUND DUFER #12 REINFORCED STEEL #66 MASONRY PRE GROUT □ GROUT D WALL DRAINS ~ TILT PANELS #11 POUR STRIPS ---------1-------+------1 #11 COLUMN FOOTINGS #14 SUBFRAME D FLOOR D CEILING #15 ROOF SHEATHING #13 EXT. SHEAR PANELS #16 INSULATION #18 EXTERIOR LATH #17 INTERIOR LATH & DRYWALL BLDG-FINAL #22 D SEWER & BL/CO D PL/CO #21 UNDERGROUND WASTE liQWTR #24 TOP OUT ASTE ~R #27 TUB & SHOWER PAN #23 □GAS TEST □ GAS PIPING #25 WATER HEATER #28 SOLAR WATER Date Ins ector #51 POOL EXCAV / STEEL #52 PLUMBING #53 ELEC /CONDUIT/WIRING EQUIPOTENTIAL BOND ~ PREPLASTER / FENCE/ ALARMS #57 GUNITE BLDG-FINAL REV 9/17 #34 ROUGH ELECTRIC / EV CHARGER #33 0 ELEC SERVICE #32OTEMPORARY #35 PHOTO VOLTAIC #38 SIGNS BLDG-FINAL CODE# MECHANICAL #41 UNDERGROUND DUCTS & PIPING #44 0 DUCT & PLENUM O REF. PIPING #43 HEAT-AIR COND. SYSTEMS A/S UNDERGROUND VISUAL A/S UNDERGROUND HYDRO A/S UNDERGROUND FLUSH A/S OVERHEAD VISUAL A/S OVERHEAD HYDROSTATIC A/S FINAL F/A ROUGH-IN F/A FINAL FIXED EXTINGUISHING SYSTEM ROUGH-IN FIXED EXTING SYSTEM HYDROSTATIC TEST FIXED EXTINGUISHING SYSTEM FINAL MEDICAL GAS PRESSURE TEST MEDICAL GAS FINAL Date Ins ector SEE BACK FOR SPECIAL NOTES Construction Testing & Engineering, Inc. Inspection I Testing I Geolechnical J Environmental & Construction Engineering I Civil Engineering I Surveying INSPECTION REPORT PROJECT NAME _''{~_,,_c:..~-°' _, -~i'-"a"'-~~•-• ___ L_ ADDRESS ARCHITECT ENGINEER I l i \ I CONTRACTOR ( r , l /, r L ------------- O THE R INSPECTION DATE PLAN FILE/OTHER BLDG. PERMIT/OTHER .-/r, I, INSPECTION □ CONCRETE □ REINF. STEEL □ MASONRY □ P.T. CONCRETE □ FIELD WELDING □ SHOP WELDING □ BATCH PLANT □ EXP. ANCHOR □ OTHER f I MATERIAL SAMPLING PAGE OF GTE JOB NO. 'c t.., l-' t.J. ------ REPORT NO. MATERIAL IDENTIFICATION CONC. MIX NO. & lb/in2 GROUT MIX NO. & lb/in2 MORTAR TYPE & lb/in2 REINF. STEEL GR./SIZE STRUCTURAL STEEL HIGH-STRENGTH SOLT MASONRY BLOCK OTHER ..: <-/;( 0 CONCRETE O MORTAR O GROUT 0 FIREPROOFING O MASONRY BLOCK 0 REINFORCING STEEL O STRUCTURAL STEEL 0 BOLTS O OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. 4 I ( ... .. r .j (• ( <.A ,. , -{. T ,.. ' r rl ' _j, I Ii,~" ~· I 4 " ' y rr r 'I ,.{ r I I L r-4 ' -f. f -I ( It 1 " .r c., Certification of Compliance: All work, unless otherwise noted, compiles with applicable codes and the approved plans and specifications. PRINTED NAME _ _.1_1."'--1=c_..._. _,_, __ __,_.-"-r-=··-=-· _':....• .:...:_ __ ( CERTIFICATION NO. •-• ,-/4 --"-------'--------SIGNATURE --------,=----- ( }I 1441 Montiel Road, Suite 115 I Escondido, CA 92026 Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net GEOSOILS, INC. W.O.: 7377-C-SC -------------Geoteehnlcal-Coastal-Geologic -Environmental DATE: 04/22/19 ------------NAME: TODD ------------HOURS: 2.5 ------------ FOOTING TRENCH OBSERVATION SUMMARY CLIENT NAME: CAL-WEST PROJECT NAME: VADA ------------- LOCATION/TRACT: VADA PL, CARLSBAD. CALIF UNIT/PHASE/LOTS: LOTS 1,2, 7 ,8,AND 12 REFERENCED GEOTECHNICAL REPORT: 6927-A-SC DATED AUGUST 3, 2015 OBSERVATION SUMMARY TG INITIALS -------04122/19 DATE TG INITIALS -------04122/19 DATE ------- TG INITIALS -------04122119 DA TE TG INITIALS ------- 04122119 DATE ------- A representative of GeoSoils, Inc. observed on site soil and footing conditions. Son conditions in the trench are generally free of loose soil and debris, non-yielding and uniform, and plumb; and are in general conformance with those indicated in the geotechnical report. A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing excavations generally extend to proper depth and bearing strata, and are in general conformance with recommendations of the geotechnlcal report A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if applicable). The setback was in general accordance with the recommendations of the geotechnical report. CONSULT THE PROJECT STRUCTURAL ENGINEER ABOUT GRAVEL FROM UTILITY LINE ADJACENT NE CORNER OF LOT 12. NOTES TO SUPERINTENDENT/FOREMAN 1. Footing excavations should be cleaned of loose debris and thoroughly moistened just prior to placing concrete. 2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the geotechnical report for presoaking recommendations. We note that clayey soils may take an extended period time for such, aitd the contractor should schedule accordingly. 3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, etc.), we should be contacted to perform additional site observations and/or testing~ 4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's design, If different from the geotechnical report. NOTES TO BUILDING INSPECTOR Soll compaction test results, as well as depth of fill, relative compaction, bearing values, corrosMty, and soil expansion index test results are contained in the As-Graded Geotechnical or Final Compaction Report provided al the completion of grading. DIGITAL DELIVERY: JIM HALL Representative of Geosons. Inc. b~A,lnc. land planning, civil engineering, surveying ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Enoineer March 10, 2019 w.o. 944-1289-600 Mr. Tim Frazee CITY OF CARLSBAD, Building Inspection Division 1635 Faraday Avenue Carlsbad, CA 92008 RE: BUILDING FORM VERIFICATION FOR LOTS 1, 2, 7 AND 8 OF THE YADA FAMILY FARM SUBDMSION, CT 15-11 Dear Mr. Frazee: This letter is to attest that BHA, Inc. has staked the locations for the house construction on the above-mentioned lots. We have checked the locations of the building forms of the proposed houses and found the horizontal and vertical locations to conform to the grading plans prepared by our office. If you have any questions regarding this matter, please contact our office. Sincerely, bl-tA, Inc. -14--~ Ronald L. Holloway Senior Vice President RCE29271 ~~ovEssi~k -«~ .·· . '-1( ·. ,,_,. ~ · f:! · RONALD L. 1',. . fa · HOLLOWAY • -:,,_ · t;J :_ NO. 29271 : f:'l: "' "' . * * "'-" . CJV \\, ;?"' . 4:,,li.' -. -. \l~ . or ct.\.\~ cc: Jim Hall-California West Communities K:\Civil 3D\1289\PROD\Survey\Pad-Form Ccrts\[orms\CT 15-1 l_Lots 1-2-7-8 bldg-form-vcrification.wpd 5115 Avenida Encinas, Suite L Carlsbad, California 92008-4387 (760) 931-8700 FAX (760) 931-7780 (City of Carlsbad CERTIFICATION OF SCHOOL FEES PAID B-34 Development Services Building Department 1635 Faraday Avenue 760-602-2719 www.carlsbadca.gov This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City prior to issuing a building permit. The City will not issue any building permit without a completed school fee form. Project Name _,_Y!CA,,,D"'A'-F'-'A=.,R"'M,__ ____________________ _ Building Permit Plan Check Number PC2017-0048 // CBRA2018-0057-LOT 8 Project Address: .Ll.L.7.,_,J 0LY.!..LlA...,Ou.A:u..PI,._,oA,.C"'E~--------------------- A.P.N _1...,,5.,.6:::.·2 ... 2.,.0=-•6._.1.::,•0,.,,0,_ ___________________ _ Project Applicant CARLSBAD BUENA VISTA 12, LP (Owner Name) Project Description: _1'-=S'-F=D __________________________ _ Building Type Residential: 1 NEW DWELLING UNIT(S) 3,004 Square Feet of Living Area in New Dwelling/s Second Dwelling Unit: Square Feet of Living Area in SDU ' Residential Additions: Net Square Feet New Area Commercial/Industrial: Net Square Feet New Area City Certification of Applicant Information, SYI-Cl3/ Evew Date November 30, 2018 SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD C8J Carlsbad Unified School District 6225 El Camino Real Carlsbad CA 92009 (760-331-5000) LJ Encinitas Union School District- By appointment only 101 South Rancho Santa Fe Rd Encinitas, CA 92024 /760-944-4300 x1166) D Vista Unified School District D San Marcos Unified School District 1234 Arcadia Drive 2 5 5 P i c o A v e S t e . 1 0 0 Vista CA 92083 (760-726-2170) xt San Marcos, CA 92069 (760-290-2649) 2222 Contact: Katherine Marcelja (By Appt. Only) LJ San Dieguito Union High School District-By Appointment Only 684 Requeza Dr. Encinitas, CA 92024 (760-753-6491 X 5514) Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of perjury that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number of dwelling units or square footage after the building permit is issued or if the initial determination of units or square footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or that the person executing this declaration is authorized to sign on behalf of the Owner. Signature: _/i---+-;?..L-1--4-=-=-J__~=----=--=--__ Date: l 7 B-34 Page 1 of 2 Rev. 03/09 SCHOOL DISTRICT SCHOOL FEE CERTIFICATION (To be completed by the school district(s)) *************************************************************************************************** THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE PROJECT HAVE BEEN OR WILL BE SATISFIED. SCHOOL DISTRICT: The undersigned, being duly authorized by the applicable School District, certifies that the developer, builder, or owner has satisfied the obligation for school facilities. This is to certify that the applicant listed on page 1 has paid all amounts or completed other applicable school mitigation determined by the School District. The City may issue building permits for this project. SIGNATURE OF AUTHORIZED SCHOOL DISTRICT OFFICIAL TITLE NAME OF SCHOOL DISTRICT DATE PHONE NUMBER •~ > £, <'.11\(i' ~ C, j i IJ «J. ; J__Q U'--, G'---'-"" -:i, · \,r-r--l1...", ') ,,.:>, 'J? ,; v ,Y\-\-----e::rv ~~ CARLSBAD UNIAED SCHOOL DISTRICT 6225 EL CAMINO BEAi, CARLSBAD, CA 92009 ) \~)5' ~\" B-34 Page 2 of 2 Rev. 03/09