HomeMy WebLinkAbout1712 CATALPA RD; ; CB001839; Permit07/28/2000
Job Address
Permit Type
Parcel No
Valuation
Occupancy Group
# Dwelling Units
Bedrooms
Project Title
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit Permit No;CB001839
Building Inspection Request Line (760) 602-2725
1712 CATALPA RD CBAD
RESDNTL
2155110500
$11,76000
27
0
0
Sub Type
Lot#
Construction Type
Reference #
Structure Type
Bathrooms
RAD
0
VN
RAD 120 SF - OFF MSTR BD RM
Status
Applied
Entered By
Plan Approved
Issued
Inspect Area
Orig PC#
Plan Check#
ISSUED
05/09/2000
JM
07/24/2000
07/28/2000
Applicant
ZINGERMAN JOEL P&KATHLEEN
1712 CATALPA RD
CARLSBAD CA 92009
Owner
ZINGERMAN JOEL P&KATHLEEN
1712 CATALPA RD
CARLSBAD CA 92009
4383 07/28/00 OOOi 01 02
C-PRMT 152-26
Total Fees $237 46 Total Payments To Date $8520 Balance Due $15226
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
Pot Water Con Fee
Meter Size
Add'l Pot Water Con Fee
Reel Water Con Fee
$131 08 Meter Size
$0 00 Add'l Reel Water Con Fee
$85 20 Meter Fee
SO 00 SDCWA Fee
$0 00 CFD Payoff Fee
$1 18 PFF
$000 PFF (CFD Fund)
$0 00 License Tax
$0 00 License Tax (CFD Fund)
$0 00 Traffic Impact Fee
$0 00 Traffic Impact (CFD Fund)
$0 00 LFMZ Transportation Fee
$0 00 Sidewalk Fee
$0 00 PLUMBING TOTAL
$0 00 ELECTRICAL TOTAL
$0 00 MECHANICAL TOTAL
$0 00 Housing Impact Fee
Housing InLieu Fee
$0 00 Master Drainage Fee
$0 00 Sewer Fee
TOTAL PERMIT FEES
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$000
$2000
$000
$000
$000
$000
$000
$237 46
Inspector
FINAL APPROVAL
Date Clearance
NOTICE Please take NOTICE that approval of your project includes the Imposition of fees dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any ofher required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions^DOES NGfl
changes, nor planning, zoning, grading or other similar application processing or service fees in connectior
fees/exactions of which you have previously been given a NOTICE similar to this
SATE
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave , Carlsbad, CA 92008
PROJECT
FOR OFFICE USE ONLY
PLAN CHECK NO C
EST VAL
Plan Ck Deposit
Validated By
Pate
Address (include Bldg/Suit Business Name (A this address)
Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor's Parcel Existing Use Proposed Use
Description of Work
{2!1iliCONTACT^PER^6'Np("lf^ffaVantVdmiap^icant)
FT #of Stones ft of Bedrooms # of Bathrooms
6713 05/09/00 OOOi 01 02
Address
O'Agent [fortContractor '•i|£JOwneri!,rj_J Agent for
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor s License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars IS5001)
Name
State License tt
Address
License Class
City State/Zip
City Business License tt
Telephone tt
Designer Name
State License #
Address City State/Zip Telephone
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit'S issued
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS |$100) OR LESS)
n CERTIFICATE OF EXEMPTION 1 certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California
WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($100 000), in addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees
SIGNATURE DATE
i7 .^OWNER-BUILDER DECLARATION <\_
I hereby affirm that I am exempt from the Contractor s License Law for the following reason
Q I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however the building or improvement is
sold wiihin one year of completion, the owner builder will have the burden of proving that he did not build or improve for the purpose of sale)
fj I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law)
Q I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement |~l YES QNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone number / type
of work)"
BUILDING
Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention
program under Sections 25505 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q YES Q NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES Q NO
IF ANY OF THE ANSWERS ARE YES A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 30970) Civil Code)
LENDER S NAME LENDER S ADDRESS _ _ _
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances antj State laws relating to building construction I hereby authorize representatives of the CitV of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES
JUDGMENTS COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA ftermit is required for excavations over 5 0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work
authorized by such permit is not corrunenced within 180 days from the date of such permit or if the building or work authorized by sjich permit is suspended or abandoned
afJfirJhfijftfork is com\neAtjed torjfe B£«9d of 180/lays (Section 106 4 4 Uniform Building Code)
^ DATEAPPLICANT'S SIGNATURE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad
Building Department
June 7, 2001 Permit Number
Issue Date
CB001839
7/28/2000
ZINGERMAN RESIDENCE
1712 CATALPA RD
CARLSBAD CA 92009
RE: BUILDING PERMIT EXPIRATION
PERMIT TYPE: RESDNTL
ADDRESS: 1712 CATALPA RD
PLEASE CALL FOR AN INSPECTION IF WORK IS
COMPLETE
Our records indicate that your building permit will expire by limitation of time on 7/30/2001
The provisions of UBC, Section 106 4 4 as amended by the Carlsbad Municipal Code state "EXPIRATION
Every permit issued by the Building Official under the provisions of this code shall expire by limitation and
become null and void if the building or work authorized by such permit is not commenced within 180 days
from the date of such permit (unless issued prior to 7/1/99 which is one year from date of permit), or if the
building or work authorized by such permit is stopped at any time after the work is commenced for a period of
180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance
date of permit Work shall be presumed to have commenced if the permittee has obtained a required inspection
approval of work authorized by the permit by the Building Official within 180 days of the date of permit
issuance Work shall be presumed to be stopped if the permittee has not obtained a required inspection
approval of work by the Building Official within each 180 day period upon the initial commencement of work
authorized by such permit
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall
be one-half the amount required for a new permit for such work, and provided that no changes have been made
or will be made in the original plans and specifications for such work, and provided further that such
suspension or abandonment has not exceeded one year In order to renew action on a permit after expiration,
the permittee shall pay a new permit fee
Any person holding an unexpired permit may apply for an extension of the time within which work may
commence under that permit when the permittee is unable to commence work within the time period required
by this section for good and satisfactory reasons The Building Official may extend the time for action by the
permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances
beyond the control of the permittee have prevented action from being taken No permit shall be extended more
than once
Please check below indicating your intentions and return this letter to us
Project abandoned A new permit will be obtained prior to commencing work
No fee extension requested for 180 days (attach a letter of explanation)
Renewal permit requested
If the project has been completed and only a final inspection is needed, please call the inspection request line at
(760) 602-2725
If you have any questions, please contact the Building Inspection Department at (760) 602-2700
PAT KELLEY
Principal Building Inspector
1635 Faraday Avenue • Carlsbad, CA 92008-7314
Building Counter • (76O) 6O2-2719
(760) 602-27OO • FAX (76O) 602-8560
FAX (76O) 6O2-8558
City of Carlsbad
Building Department
December 13, 2000
ZINGERMAN RESIDENCE
1712CATALPARD
CARLSBAD CA 92009
RE: BUILDING PERMIT EXPIRATION
PERMIT TYPE: RESDNTL
Permit Number
Issue Date
CB001839
7/28/2000
ADDRESS: 1712 CATALPA RD
PLEASE CALL FOR AN INSPECTION IF WORK IS
COMPLETE
Our records indicate that your building permit will expire by limitation of time on 1/30/2001
The provisions of UBC, Section 106 4 4 as amended by the Carlsbad Municipal Code state "EXPIRATION
Every permit issued by the Building Official under the provisions of this code shall expire by limitation and
become null and void if the building or work authorized by such permit is not commenced within 180 days
from the date of such permit (unless issued prior to 7/1/99 which is one year from date of permit), or if the
building or work authorized by such permit is stopped at any time after the work is commenced for a period of
180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance
date of permit Work shall be presumed to have commenced if the permittee has obtained a required inspection
approval of work authorized by the permit by the Building Official within 180 days of the date of permit
issuance Work shall be presumed to be stopped if the permittee has not obtained a required inspection
approval of work by the Building Official within each 180 day period upon the initial commencement of work
authorized by such permit
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall
be one-half the amount required for a new permit for such work, and provided that no changes have been made
or will be made m the original plans and specifications for such work, and provided further that such
suspension or abandonment has not exceeded one year In order to renew action on a permit after expiration,
the permittee shall pay a new permit fee
Any person holding an unexpired permit may apply for an extension of the time within which work may
commence under that permit when the permittee is unable to commence work within the time period required
by this section for good and satisfactory reasons The Building Official may extend the time for action by the
permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances
beyond the control of the permittee have prevented action from being taken No permit shall be extended more
than once
Please check below indicating your intentions and return this letter to us
Project abandoned A new permit will be obtained prior to commencing work
No fee extension requested for 180 days (attach a letter of explanation)
Renewal permit requested
If the project has been completed and only a final inspection is needed, please call the inspection request line at
(760) 602-2725
If you have any questions, please contact the Building Inspection Department at (760) 602-2700
PAT KELLEY
Principal Building Inspector
1635 Faraday Avenue • Carlsbad, CA 92OO8-7314 • (76O) 6O2-27OO • FAX (760) 6O2-8560
January 18, 2001
1712CatalpaRoad
Carlsbad, CA 92009
City of Carlsbad Building Department
1635 Faraday Ave
Carlsbad, CA
92008-7314
Re Permit Number CBOO1839 Request for no-fee extension
Dear Sir or Madam
I am requesting a 180 day no-fee extension of the subject permit due to finamcal
difficulties in completing the construction
Thank you
'sV'A^Regards, ^ \
•*iYs°\Joel Zingerman U
City of Carlsbad
Building Department
December 13, 2000
ZINGERMAN RESIDENCE
1712CATALPARD
CARLSBAD CA 92009
RE: BUILDING PERMIT EXPIRATION
PERMIT TYPE: RESDNTL
Permit Number
Issue Date
CB001839
7/28/2000
ADDRESS: 1712 CATALPA RD
PLEASE CALL FOR AN INSPECTION IF WORK IS
COMPLETE
Our records indicate that your buildmg'permit will expire by limitation of time on 1/30/2001
The provisions of UBC, Section 106 4 4 as amended by the Carlsbad Municipal Code state "EXPIRATION
Every permit issued by the Building Official under the provisions of this code shall expire by limitation and
become null and void if the building or worlc'authorized by~sucn permit is not commenced witnm 180 davs
from the date of such permit (unless issued prior to 7/1/99 which is one year from date of permit), or if the
building or work authorized by such permit is stopped at any time after the work is commenced for a period of
180 days or if the building or work authorized by such permit exceeds three calendar years from the issuance
date of permit Work shall be presumed to have commenced if the permittee has obtained a required inspection
approval of work authorized by the permit by the Building Official within 180 days of the date of permit
issuance Work shall be presumed to be stopped it the permittee has not obtained a required inspection
approval of work by the Building Official within each 180 day period upon the initial commencement of work
authorized by such permit
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall
be one-half the amount required for a new permit for such work, and provided that no changes have been made
or will be made in the original plans and specifications for such work, and provided further that such
suspension or abandonment has not exceeded one year In order to renew action on a permit after expiration,
the permittee shall pay a new permit fee
Any person holding an unexpired permit may apply for an extension of the time within which work may
commence under that permit when the permittee is unable to commence work within the time period required
by this section for good and satisfactory reasons The Building Official may extend the time for action by the
permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances
beyond the control of the permittee have prevented action from being taken No permit shall be extended more
than once
Please check below indicating your intentions and return this letter to us
^—-Project abandoned A new permit will be obtained prior to commencing work
No fee extension requested for 180 days (attach a letter of explanation)
Renewal permit requested
If the project has been completed and only a final inspection is needed, please call the inspection request line at
(760) 602-2725
If you have any questions, please contact the Building Inspection Department at (760) 602-2700
PAT KELLEV
Principal Building Inspector
1635 Faraday Avenue • Carlsbad, CA 92OO8-7314 - (760) 602-270O * FAX (760) 602-856O
EsGil Corporation
In Partnership with Government for Building Safety
DATE 7/20/00
JURISDICTION City of Carlsbad
Q APPLICANT
a PLAN REVIEWER
a FILE
PLAN CHECK NO OO-1839
PROJECT ADDRESS 1712 Catalpa Rd.
PROJECT NAME Room Addition
SET III
XI The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The item in the remarks transmitted herewith is for your information The plans are being held at
Esgil Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted
Date contacted
Mail Telephone
REMARKS.
(by )
Fax In Person
Telephone #
Fax #
By Doug Moody
Esgil Corporation
D GA D MB D EJ D PC
Enclosures
LOG trnsmtl dot
9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 4 (858)560-1468 4 Fax (858) 560-1576
EsGiJ^Corporation
In Partnership with Government for Building Safety
DATE- 6/9/00 Q APEUANT
JURISDICTION City of Carlsbad a PLAN REVIEWER
Q FILE
PLAN CHECK NO : 00-1839 SET II
PROJECT ADDRESS 1712 Catalpa Rd
PROJECT NAME Room Addition
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
X) The remarks below are transmitted herewith for your information The plans are being held at
Esgil Corporation until corrected plans are submitted for recheck Bring one corrected set of plans and
calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123,
(858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
X] The applicant's copy of the check list has been sent to
Joel Zmgerman
1712 Catalpa Rd Carlsbad, Ca 92009
Esgil Corporation staff did not advise the applicant that the plan check has been completed
XI Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Matt Cornforth Telephone # 760-727-1422
Date contacted 0 /9/00 (by i^ ) Fax # (^Go^M ;<-/2Z-
Telephone^ Fax w In Person
X REMARKS Item # 18 Please show lateral force resisting design for all exterior wall lines
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 6/2/00 trnsmtl dot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858)560-1468 + Fax (858) 560-1576
J UN- 09-80
FAX TO:
NAME:,
FAX;
PHONE:
NO. OF PACES;.
DATE
City of Carlsbad
JPlumbing - Electrical - Mechanical Worksheet
4-Ovi
Permit
Questions below refer to work being done for this permit only.
Plumbine
* Number of new or relocated fixtures, traps, or floor drains? _ ~ W^*e
* New building sewer line?
* Number of roof drains?
* install/alter water line?
* Number of water heaters9
* Number of hose bibs?
» Gas piping system - Wo^
« Number of new or relocated gas outlets
» New water meter -
Electrical
» Number of new panels or subpanels9
Size of New Service
» Single Phase D Size Number of amperes
* Three Phase D Number of amperes
* Three Phase - 480 Number of amperes
* Remodel (relocate existing outlets/switches or add outlets/switches Y« \S No
* Number of furnaces, A/C, or heal pumps7
* Number of fireplaces? '
* Number of exhaust fans'*
» Number of exhaust hoods9
» Number of boilers or compressors9 ^ _^^_
* New or relocated duct work**
BEFORE THE PERMIT CAN BE FEE'D OUT THIS FORM NEEDS TO BE RETURNED TO THE
BUILDING DEPARTMENT - FAX NUMBER (760) 602-8558
EsGil Corporation
In Partnership with Government for Building Safety
DATE 5/16/00
JURISDICTION Carlsbad Q PLAN REVIEWER
Q FILE
PLAN CHECK NO OO-1839 SET I
PROJECT ADDRESS 1712 Catalpa Rd
PROJECT NAME Room Addition
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
XI The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
XI The applicant's copy of the check list has been sent to
Joel Zmgerman
1712 Catalpa Rd Carlsbad, Ca 92009
Esgil Corporation staff did not advise the applicant that the plan check has been completed
X| Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted. Matt Cornforth ^M Telephone # 760-727-1422
Date contacted *^lr\ (byT~5>) Fax #
Mail ^Telephone— Fax In Person
REMARKS
By Doug Moody Enclosures
Esgil Corporation
D GA D MB D EJ D PC 5/11/00 tmsmUdot
9320 Chesapeake Drive, Suite 208 4- San Diego, California 92123 4 (858)560-1468 4- Fax (858) 560-1576
Carlsbad OO-1839
5/16/00
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO 00-1839 JURISDICTION Carlsbad
PROJECT ADDRESS 1712 Catalpa Rd
FLOOR AREA 120 STORIES 1
HEIGHT
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 5/9/00
DATE INITIAL PLAN REVIEW
COMPLETED- 5/16/00
DATE PLANS RECEIVED BY
ESGIL CORPORATION 5/11/00
PLAN REVIEWER Doug Moody
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled This plan review
is based on regulations enforced by the Building Department You may have other corrections
based on laws and ordinance by the Planning Department, Engineering Department, Fire
Department or other departments Clearance from those departments may be required prior to
the issuance of a building permit
Present California law mandates that residential construction comply with the 1998 edition of
the California Building Code (Title 24), which adopts the following model codes 1997 UBC,
1997 UPC, 1997 UMC and 1996 NEC (all effective 7/1/99)
The above regulations apply to residential construction, regardless of the code editions adopted
by ordinance
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
T_p speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when vou submit the revised plans.
Carlsbad 00-1839
5/16/OO
Please make all corrections on the original tracings, as requested in the correction
list Submit three sets of plans for commercial/industrial projects (two sets of plans
for residential projects) For expeditious processing, corrected sets can be
submitted in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760)
602-2700 The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engmeenng and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
1 Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 1998 edition of the California Building Code (Title 24), which
adopts the 1997 UBC, UMC and UPC and the 1996 NEC
2 Ail sheets of plans must be signed by the person responsible for their
preparation (California Business and Professions Code)
3 Specify on the plans the following information for the roof materials, per Section
10633
a) Manufacturer's name
b) Product name/number
ICBO approval number, or equal
4 Specify roof slope Please show the existing roof line and provide a detail
snowing the attachment of the new roof to the existing roof
5 Please revise roof sheeting to 7* minimum or specify blocking at edges
6 Provide skylight details to show compliance with Sections 2409 and 2603, or
specify on the plans the following information for the skylight(s), per Section
10633
a) Manufacturer's name
b) Model name/number
c) ICBO approval number, or equal
Carlsbad 00-1839
5/16/OO
7 Please provide a detail showing the attachment of the new foundation to the
existing foundation
8 Glazing in the following locations should be of safety glazing material in
accordance with Section 2406 4 Fixed or operable panels adjacent to a door
where the nearest exposed edge of the glazing is within a 24-inch arc of either
vertical edge of the door in a closed position and where the bottom exposed
edge of the glazing is less than 60 inches above the walking surface
9 Detail the framing between the existing and new construction Is there an
existing header over the opening between the new and existing
10 Show blocking at ends and at supports of rafters and at exterior walls Section
2320 8 3
11 Ridge must be designed as a beam The 2x8 will not comply with the code
12 In open beam construction, provide strap ties across the beams at the ridge
support Section 2303 8
13 Note on the plans that "all weather-exposed surfaces shall have a
weather-resistive barrier to protect the interior wall covering and that exterior
openings shall be flashed in such a manner as to make them weatherproof
Section 1402 Please note on the plans the type of exterior wall finish
14 Note on the plans that receptacle outlet locations will comply with NEC Art
210-52(a)
15 Show at least one wall switch-controlled lighting outlet to be installed at the
exterior side of outdoor entrances or exits NEC Art 210(a)
16 Please show a landing at the exterior door not less than the width of the door
and extending not less than 36"m the direction of travel
17 It appears on the plot plan that there are wall extension that do not appear on the
foundation plan, the framing, or the roof plan Please clarify
18 How do you intend to provide lateral support for the addition The plans do not
show braced wall panels as required by the code for conventional construction
19 Please provide complete energy design documents Please attach to the plans a
signed copy of the energy form CF-1R
Carlsbad 00-1839
5/16/OO
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, t e , plan sheet, note or detail number,
calculation page, etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly
describe them and where they are located in the plans
• Have changes been made to the plans not resulting from this correction list?
Please indicate
Yes Q No a
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of
858/560-1468, to perform the plan review for your project If you have any
questions regarding these plan review items, please contact Doug Moody at
Esgil Corporation Thank you
Carlsbad 00-1839
5/16/00
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad PLAN CHECK NO OO-1839
PREPARED BY Doug Moody DATE 5/16/00
BUILDING ADDRESS 1712 Catalpa Rd
BUILDING OCCUPANCY R3 TYPE OF CONSTRUCTION VN
BUILDING
PORTION
addition
Air Conditioning
Fire Sprinklers
TOTAL VALUE
BUILDING AREA
( Sq Ft )
120
VALUATION
MULTIPLIER
9800
VALUE ($)
11,760
11,760
D 1994 UBC Building Permit Fee
D 1994 UBC Plan Check Fee
Bldg Permit Fee by ordinance $ 13107
Plan Check Fee by ordinance $ 85 19
Type of Review n Complete Review Q Structural Only
Repetitive Fee Applicable
Comments
D Other.
Esgil Plan Review Fee
D Hourly
$ 6815
Sheet 1 of 1
macvalue doc 5100
City of Carlsbad
Public Works — Engineering
DATE T^\n)
BUILDING ADDRESS
PROJECT DESCRIPTION
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO
llii "
CB 1*39
ASSESSOR'S PARCEL NUMBER $\-
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal, therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build
[A Right-of-Way permit is required prior to
construction of the following improvements
EST VALUE
DENIAL
Please see the attached report of deficiencies
marked with D Make necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
By
By
By
Date
Date
Date
By
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT
Date
ATTACHMENTS
D Dedication Application
Q Dedication Checklist
U Improvement Application
D Improvement Checklist
D Future Improvement Agreement
D Grading Permit Application
Q Grading Submittal Checklist
D Right-of-Way Permit Application
Q Right-of-Way Permit Submittal Checklist
and Information Sheet
Q Sewer Fee Information Sheet
ENGINEERING DEPT CONTACT PERSON
Name KATHLEEN M FARMER
City of Carlsbad
Address 1635 Faraday Avenue
Phone (760) 602-2741
CFD INFORMATION
Parcel Map No
Lots
Recordation
Carlsbad Tract
A-4
1635 Faraday Avenue - Carlsbad, CA 92OO8-7314 • (76O) 6O2-272O • FAX (76O) 602-8562
iSTV
a 3RD/
a
Q
BUILDING PLANCHECK CHECKLIST
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
North Arrow
B^Existmg & Proposed Structures
Street Improvements
/
13
•B" Property Lines
•€"" Easements
Right-of-Way Width & Adjacent Streets
Driveway widths
2 Show on site plan
Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
Existing & Proposed Slopes and Topography
3 Include on title sheet
A Site address
B Assessor's Parcel Number
C Legal Description
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc ) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
4a Project does not comply with the following Engineering Conditions of approval for
Project No
Q Q 4b All conditions are in compliance Date
H WVORD\FARMER\KATHY\HASTERS\Buikiing Plancfieck CMst BP0001 Form KF Hoc
BUILDING PLANCHECK CHECKLIST
DEDICATION REQUIREMENTS
5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
dram or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ , pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 Yz" x 11" plat map
and submit with a title report All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist for the dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
Q
Q
IMPROVEMENT REQUIREMENTS
6a All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ , pursuant to Carlsbad Municipal Code
Section 18 40 040
Public improvements required as follows __„„
Attached please find an application form and submittal checklist for the public
improvement requirements A registered Civil Engineer must prepare the
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process The completed application form and the requirements on the
checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by Date
6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $ so
we may prepare the necessary Future Improvement Agreement This agreement
must be signed, notarized and approved by the City prior to issuance of a
Building permit
Future public improvements required as follows
H 1WORD\FARMEFfiKATHY\M\STER3\BulklinQ Plancheck CKlsl BP0001 Form KF doc
V BUILDING PLANCHECK CHECKLIST
-ist/
Q
2nd/ ordOa Q
a Q
6c Enclosed please find your Future Improvement Agreement
agreement signed and notarized to the Engineering Department
Future Improvement Agreement completed by
Date
Please return
6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
Q
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11 06 030 of the Municipal Code
Q 7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities (cut, fill import, export)
Q 7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
Grading Inspector sign off by Date
a a Q 7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required }
Q Q Q 7d No Grading Permit required
Q Q Q 7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
Q Q Q 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tiemg
into public storm drain, sewer and water utilities
Right-of-Way permit required for
H \WORD\FARMER\KATHYWASTERS\Building PlancHecK Cklst BPOOOt Form KF doc
BUILDING PLANCHECK CHECKLIST
a
3rd'a
a
a a
a
a
a a
a a
a a
A SEWER PERMIT is required concurrent with the building permit issuance
fee is noted in the fees section on the following page
The
10 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 153, for
assistance
Industrial Waste permit accepted by
Date
11 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
12 Q Required fees are attached
£j No fees required
13 Local Facilities Management Zone Transportation Fee Agmt Signed
14 Additional Comments:
H \WORD\FARMER\KATHY\MASTERS\Building Plandlech Chlsl BPOOO! Form KF doc
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB 00-
Planner
APN:
'Address /7/q
Greg Fisher Phone (760) 602-4629
Type of Project & Use:
Zoning-.
CFD fin/nnti #
Circle One
General Plan:
Net Project Density
Facilities Management Zone
DU/AC
Date of participation:Remaining net dev acres
{For non-residential development Type of land used created by
this permit )
Legend: /\ Item Complete
Environmental Review Required:
DATE OF COMPLETION: -
YES
Item Incomplete - Needs your action
NO TYPE
Compliance with conditions of approval7 If not, state conditions which require action
Conditions of Approval'
Discretionary Action Required:
APPROVAL/RESO NO
PROJECT NO
YES NO TYPE
DATE
OTHER RELATED CASES:
Compliance with conditions or approval7 If not, state conditions which require action
Conditions of Approval
NO Y
Coastal Zone Assessment/Compliance ,.
Project site located in Coastal Zone7 YES_^ NO
CA Coastal Commission Authority7 YES
If California Coastal Commission Authority Contact them at -"3111 Cammo Del Rio North, Suite
200, San Diego CA 92108-1725, (619) 521-8036
Determine status (Coastal Permit Required or Exempt)
Coastal Permit Determination Form already completed7
If NO, complete Coastal Permit Determination Form now
Coastal Permit Determination Log #. uA^~"
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed
H \ADMIN\COUNTER\BldgPlnchkRevChklst
Inclusionary Housing Fee required. YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993 }
Data Entry Completed? YES NO ,
(A/P/Ds Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee UPDATE')
Site Plan.
1 Provide a fully dimensional site plan drawn to scale. Show* North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number
BTV
Zoning:
1. Setbacks:
Front:
Interior Side
Street Side:
Rear:
Required ^ C2
Required
Required
Required
2 Accessory structure setbacks
Front: Required
Interior Side: Required
Street Side: Required
Rear: Required
Structure separation: Required
3. Lot Coverage-
Height.
Required
Required
5. Parking: Spaces Required
Guest Spaces Required
Additional Comments
L~<M
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
s -)
3
7
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER // i
H \ADMIN\COUNTER\Bldgp|nchkRevChklst
DATE
\>
•*•——
*iD
*** m^ ^
fJ?
^Jb /-
4
k
V
I \
h
i >
'p
•?
Ix
3r
£
tOf
E»
^P
«^
*
LL
X
£
• Is* \\
G4
^^•^^
NAILING. All nailing shall comply with Table 23-l-Q below
UBC TABLE 23-l-Q - NAILING SCHEDULE
CONNECTION
1 Joist to Sill or girder, Toenail
2 Bndg ng to joist, toenail each end
..3 1"XO" subfloor or Icoo to «dUi luiot. foco nod — —
-5r-£" subfloor to joiot or girder, blind diiu fauj iidil —
6 Sole plate to joist or blocking, typical face nail
Sole plate to joist or blocking, at braced wall panel
7 Top plate to stud, end nail
8 Stud to sole plate
9 Double studs, face nail
10 Doubled top plates, typical face nail
Double top plates, lap splice
1 1 Blocking between joist or rafters to top plate, toenail
12 Rimjoist to top plate, toenail
13 Top plates, laps and intersections, face nail
14 Continuous header, two pieces
15 Ceiling joists to plate, toenail
16 Continuous header to stud, toenail
17 Ceiling joists, laps over partitions, face nail
16 Ceiling joists parallel to rafters, face nail
19 Rafter to plate, toenail
20 1" brace to each stud and plate, face nail
21 1" x 8" sheathing or less to each beanng, face nail
22 Wider than 1" x 8" sheathing to each bearing, face nail
23 Built-up comer studs
24 Built up girder and beams
25 2 x planks
26 Wood structural panels and partjcleboard 2
Subfloor, roof and wall sheathing {to framing)
Va" and less
19/32"-3/4"
7/8" - 1"
1 1/8 " - 1 '//
Combination subfloor underiayment (to framing)
*/i" and less
7/8" -1"
1 1/8' - 1 '//
27 Panel siding (to framing)
Yi" or less
5/8"
28 Fiberboard sheathing 7
y/
25/32"
29 Interior paneling
y/
3/8"
NAILING,
3-8d
2-8d• — — -2=ett*
16d at 16"o c
3-16dper16"
2-16d
4-8d, toenail or 2-16d, end nail
1 6d @ 24" o c
16d@16"oc
8-16d
3-8d
8d @ 6" o c
2-1 6d
16d @ 16" o c along each edge
3-8d
4-8d
3-16d
3-16d
3-8d
2-8d
3-8d
3-8d
16d@24"oc
20d @ 32" o c at top and bottom and staggered 2-20d at
ends and at each splice
2-16d at each beanng
6d3
8d4 or 6d5
8d3
10d«or8d5
6d5
8d5
1 0d4 or 8d5
6de
8da
No, 1 1 ga s
6d4
No 16 ga6
No 1 1 ga a
&d*
No 16gaB
4d10
6d11
1 Common or box nails may be used except where otherwise stated
2 Nails spaced 6" o c at edges, 12" o c at intermediate supports except 6" at all supports where spans are 48° or more
For nailing of wood structural panel and particle board diaphragms and shear walls, refer to Section 2314 3 Nails for wall
sheathing may be common, box, or casing
3 Common or deformed shank4 Common
5 Deformed shank6 Corrosion resistant siding or casing nails conforming to the requirements of Section 2304 3
'Fasteners spaced 3" o c at extenor edges and 6" o c at intermediate supports8 Corrosion resistant roofing nails with 7/16" diameter head and 1 V4" length for !£" sheathrng and 1 3xi" length for 25/32"
sheathing conforming to the requirements of Section 2304 39 Corrosion resistant staples with 7/16" crown and 1 1/8" length for V," sheathing and 1 Yi" length for 25/32" sheathing
conforming to the requirements of Section 2304 310 Panel supports at 16"o c [ 20" if strength axis in the long direction of the panel, unless otherwise marked] Casing or
finish nails spaced 6" on panel edges, 12" at intermediate supports11 Panel supports at 24" Casing or finish nails spaced 6" on panel edges, 12" at intermediate supports
iV. GENERAL REQUIREMENTS
DEFINITION
Habitable Space (Room) is space in a structure for living, sleeping, eating, or cooking Bathrooms, toilet
compartments, closets, hails, storage or utility space, and similar areas are not considered habitable space
ROOM DIMENSIONS
Floor Area Dwelling units shall have at least one room which shall have at not less than 120 s f of floor area
Other habitable rooms except kitchens shall have an area of not less than 70 s f
Width Habitable rooms other than a kitchen shall be not less than 7 feet in any dimension
Ceiling Heights Habitable space shall have a ceiling height of not less than 7'6" measured to the bottom of the
finished ceiling Kitchens, halls, bathrooms and toilet compartments may have a finished ceiling height of not less
than 7'
LIGHT AND VENTILATION
General For the purpose of determining the light and ventilation required by this section, any room may be
considered as a portion of an adjoining room when '/a of the area of the common wall is open and unobstructed and
provides an opening of not less than 1/10 the floor area of the interior room or 25 s f, whichever is greater
Natural light All habitable rooms shall be provided with natural light by means of exterior glazed openings with an
area not less than 1/10 the floor area of such rooms with a minimum of 10 s f
Natural Ventilation
Habitable Rooms Natural ventilation by means of openable exterior openings with an area not less than
1/20 the floor area of the room with a minimum of 5s f
Other Rooms Bathrooms, water closet compartments, laundry rooms and similar rooms (except laundry
rooms) shall be provided with natural ventilation by means of openable exterior openings with an area not
less than 1/20 the floor area of the room with a minimum openable area of 1 % s f
Mechanical Ventilation (In lieu of required exterior openings for natural ventilation)
Habitable Rooms A mechanical ventilating system capable of providing two air changes per hour may
be provided 1/5 of the air supply shall be taken from the outside
Other Rooms In bathrooms containing a bathtub or shower or combination thereof, laundry rooms and
similar rooms, a mechanical ventilation system connected directly to the outside capable of providing 5
air changes per hour may be provided The point of discharge of exhaust air shall be at least 3 feet from
any opening into the building
Attic Attic areas shall be ventilated with openings having net area of not less than 1 square foot per 150 s f of attic
area The openings shall be covered with %" (max) galvanized wire mesh
SANITATION
Toilet Facilities New water closets shall have a maximum flush capacity of 1 6 gallons, and shall be located in a
clear space not less than 30" wide There shall be a clear space in front of the water closet of not less than 24"
Shower Areas Showers shall have floors and walls finished with smooth, hard, non-absorbent surfaces such as
Portland cement, ceramic tile, or other approved matenal to a height of not less than 70" above the dram inlet
Matenals used in walls, other than structural elements, shall be of a type that is not adversely affected by moisture
Showers shall have a minimum area of 1024 square inches (net), and shall be capable of encompassing a 30"
circle
Glazing for Shower and Bathtub Enclosures Glazing used in doors and panel of shower and bathtub enclosures
shall be fully tempered 1/8" thick glass or %" laminated safety glass Hinged shower doors shall open outward
EMERGENCY ESCAPES
Emergency Egress Every sleeping room shall have at least one operable window or exterior door approved for
emergency escape These emergency escape doors or windows must provide a full clear opening and shall be
operable from the inside without the use of special tools All egress windows shall have a net opening of 5 7 s f (821
square mches)with a minimum net clear height of 24" and width of 20" The finish sill height of egress windows shall
not be more than 44" above the floor
SMOKE DETECTORS
General Smoke detectors are required for new construction of sleeping rooms and corridors or areas giving access
to sleeping rooms
Location The required smoke detector(s) shall be mounted on the wall of the sleeping room, and at a point
centrally located on the wall or ceiling of the corridor or area giving access to the sleeping room, and on each level
of the dwelling unit Detectors shall be installed according to the manufacturer's installation instructions, with no part
of the detector more than 12" from the finished surface of the ceiling
Power Required smoke detectors installed in the areas of new construction or of the addition shall receive their
pnmary power from the building wiring and shall be equipped with a battery backup Detectors may be battery
operated when installed in buildings which undergo alterations, repairs, or additions
Additions When the valuation of additions, alterations, or repairs to residential occupancies exceeds $1000,
smoke detectors shall be installed in all areas as noted above
MISCELLANEOUS
Doors Doors in all dwellings shall have a minimum width of 32"
Water Heater Location No water heater which depends on the combustion of a fuel for heat shall be installed in
any room used or designated for sleeping purposes, a bathroom, a clothes closet, or rn any confined space opening
into a bathroom or sleeping room
Water Heater Anchorage All water heaters shall be anchored to resist horizontal displacement Strapping shall be
at points within the upper 1/3 and lower 1/3 of the tank's vertical dimensions The lower strap shall be a minimum of
4" above the controls
Separation of Private Garages Every wall and ceiling separating a dwelling from a garage shall be protected on
the garage side with materials approved for one-hour fire-resistive construction, and a self-closing, tight fitting, solid
wood door a minimum 1 3/8" thick, or a listed fire resistive assembly with a rating of not less than 20 minutes Under
no circumstances shall a private garage have any openings tnto a room used for sleeping purposes Air ducts
passing through the occupancy separation wall, floor, or ceiling shall be not less than 0 019" thickness steel (No 26
gauge galvanized sheet)
Separation of Private Carports An occupancy separation need not be provided between a dwelling and a carport
having no enclosed uses above, provided the carport is entirety open on two or more sides
Attic Access An attic access opening shall be provided for attics with a vertical height greater than 30" The
opening shall be located in a hallway or other readily accessible location The opening to be a minimum of 22" by
30"
Safety Glazing Approved tempered glass shall be used in the following locations
1 Glazing in ingress and egress doors
2 Glazing in doors and enclosures for hot tubs, whirlpools, saunas, showers, and bathtubs Glazing in
any portion of a building wall enclosing these compartments where the bottom edge of the glazing is less
than 60" above the standing surface and dram inlet
3 Glazing within 24" of the swing arc of either vertical edge of a closed door when the glazing is within
60" of the walking surface
4 Glazing that meets all of the following cntena
a Individual pane >9 square feet
b Bottom edge < 18" above the floor
c Top edge > 36" above the floor
d Walking surface within 36" of glass
5 Glazing in guardrails
6 Glazing in stair enclosures and landings or within 5' of the bottom and top of stairways where the
bottom edge of the glazing is within 60" of the walking surface
Stairways All residential stairways with more than three risers shall conform to this section
1 Stairways shall be a minimum of 36" wide
2 The maximum nse is 8", and the minimum run is 9" Maximum deviation between steps is 3/8
3 Stairways shall have handrails on one side Open stairways shall have handrails on both sides
4 Open stair railings shall have intermediate rails with openings such that a 4" sphere cannot pass
through the opening
5 Handrails shall be mounted between 34" and 38" above the tread nosing The hand grip shall be
between 1 Yf and 2" in cross section dimension The must be 1Va" between the handrail and the wall
Guardrails All unenclosed floor and roof openings, open and glazed sides of stairways, landings, and ramps,
balconies or porches more than 30" above grade or the floor below must be protected by a minimum 36" guardrail
Openings in guardrails shall have intermediate rails with openings such that a 4" sphere cannot pass through the
opening
ELECTRICAL NOTES
Separate electncal plans are not required for residential construction The field inspector may require you or your
electrician to provide a "San Diego Area Circuit Card" at the time of the rough wmng inspection This will assist in the
inspection of the wmng The floor plan should show the proposed location of all new receptacles, lights, switches, and other
permanently wired electncal appliances
RECEPTACLE regulations are generally
WALLS Receptacle spacing should be at 12 feet maximum measured along the wall surface
COUNTER TOPS At every separate kitchen counter top space 4 feet on center maximum (Minimum 20 amp)
BATHROOMS One receptacle at each basin location (GFCI Protected)
OUTSIDE One receptacle at grade level at the front and back of the dwelling unit (GFCI Protected)
LAUNDRY One receptacle at for the laundry
BASEMENTS AND GARAGES One receptacle for the garage and/or basement (GFCI Protected)
HALLWAYS Hallways 10 feet or more in length shall have at least one receptacle
LIGHTING OUTLETS are also required for certain locations in dwelling units They are required at
1 One switch controlled light or receptacle in every habitable room, bathroom, hallway, stairway, attached
garage, and at outdoor entrances or exits Lighting switches for stairs shall be located at each floor level
where there are six or more steps
2 One switch controlled light at entrances to the attic, underfloor space, utility room, and basement
3 One switch controlled light near equipment requinng service in attics or under floor spaces The switch shall be
located at the point of entry
GROUND-FAULT CIRCUIT-INTERUPTION (GFCI) PROTECTION FOR PERSONNEL
The following receptacles shall be protected by GFCI receptacles or circuit breakers
1 All receptacles in bathrooms
2 All garage receptacles except appliance circuits
3 All outdoor receptacles within 6 feet of grade
4 All counter top receptacles within six feet of any sink except dedicated appliance circuits
MECHANICAL NOTES
The heating system shall be capable of maintaining a room temperature of 70°F at a point 3 feet above the floor in
all habitable rooms (Approximately 25 BTUs per square foot)
Solid fuel burning appliances or wood burning stoves will be an acceptable source of heat for a family room, den, or
living room addition only
Warm air furnaces shall not be installed in bedrooms, bathrooms or closets, or in any enclosed space with access
only through such rooms or spaces
Alcoves or closets for warm air furnaces shall be at least 12" wider than the furnace and shall provide 3" clearance
for the top, back, and sides of the furnace 6" clearance is required along the combustion chamber opening side
Clothes dryers require a minimum 4" smooth metal exhaust duct to the outside The connector may be flexible duct
Cook tops and ranges shall have 30" clearance to combustibles over the cooking surface If protected by a
ventilating hood, the clearance may be 24" All range hood ducts shall be smooth metal
B
sa-?1!
?
4
\ \\
/
/
nr^z&
er
r
£
£
6
r-c
c
f
I
_\!_ VA
4.
V J
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Page i of 2) CF-1R
Project Title
Project Address />
Documentation Author Telephone
Compliance Method (Package or Computer) Climate Zone
Date / f
Building Permii »
Plan Check / Date
Field ChtcV / Date
Enforcement Agcnc\ Use OnK
GENERAL INFORMATION
Total Conditioned Floor Area ft"Average Ceiling Height
Conditioned Slab Floor Area {'2j£» ft2
Building Type b£^ Single Family E*L Addition
(check one or more) Multi-Family Existmg-Plus-Addmon
Front Orientation
4-—Number of Stones
Number of Dwelling Units
Floor Construction Type (""Sla
North / South^East^West / All Orientations
(input front onentation in degrees from True North and circle one)
aised Floor (circle one or both)
BUILDING SHELL INSULATION
Component
Type
Wall
Wall
Roof
Roof
Floor
Floor
Slab Edee
Frame Type
wd = wood
stl = steel
UJP
\»>P
^L^P
£u&
GLe&
Cc-ti-*
Cavity
Insulation
R-Value
£-1*
(t'l>
^-3a
(Z.-^o
- —
• —
•
Sheathing
Insulation
R-Value
Total R-
Vaiue1
Assembly
U-Value1
Location/Comments
(attic, garage, typical, etc )
l^A^-S
<lflp*^'C<e&f-
<te*3{=?
Ovt<5
c^e*_>C-
^t>-^^
FENESTRATION Shading Devices
Fenestration
#/Type/Pos
FrontffSaf
Frontf-^*)
Left
LefteV«H)
Rear
Rear
Right
Right
Skyhgnt
Skvlight
Orien-
tation
) eA^r-
S£-,4fc
S&oTt-^r
K^pTH-
Area
(ft2)
^2- f?-2"
lOilo ^9
<c f<- 2-
^F<-^
Fenestration
U-Value
.50
.^ 1
. -b'l
.^3,
Fenestration
SHGC
.G5f
-7^
.«O
Interior
Shading
Att:
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Standard
Exterior
Shading Art
Overhangs
/Fins
1 For prescriptive compliance. Total R-Value and Assembly U-Value are not required for a wood-framed wall that meets
cavity R-value insulation requirement for the Prescriptive Package
; For prescriptive compliance, there are no credits for any interior shading except the default or" Standard" drapery These
delault interior shading devices (draperies) need not be installed for compliance purposes
July 1,1999
CERTIFICATE OF COMPLIANCE: RESIDENTIAL (Pane 2 of 2 CF-1R
Project Title
HVAC SYSTEMS
Date
Note Input hjdromc or combined hydronic data under Water Heating Systems except Design Heating Load
Distribution
Heating Equipment Minimum Type and Duct or
Type(^tona«^heat Efficiency Location Piping Thermostat
pump eic ) (AFUE or HSPF) (ducts, attic etc ) R- Value Type
Heat Pump
Configuration
(split nr p u.kdsO
£AS -fu£*4AKSt- t-fc^fc-Y iJclt-
. £ty£&-\ C^t££\o*JJ, ArTTl^ O^P^tefWife^iIIC-
Coolmg Equipment
Type (air conditioner
heat pump evap cooling)
Minimum
Efficiency
(SEER)
Duct
Location
(attic, etc )
Duct Thermostat
R-Value Type
Heat Pump
Configuration
(spin or packet)
i^V?£6*A ArT~^""lC-
ffisi^fc " C? T & <&*%*-
WATER HEATING SYSTEMS
_Ho ftu^ ,„
Water Heater
Type
Avpp\TT6>^;
Distribution
Type
Number
in System
Rated1
Input (kw
or Btu/hr)
Tank
Capacity
(gallons)
Energy1
Factor or
Recovery
Efficiency
Standby'
Loss(%)
External
Tank
Insulation
R-Value
G^A^-^fM^-
t"\ £> $$}j3frC^ (s-fiLJ^'fyfy&y.'f
1 For small gas storage water heaters (rated inputs of less than or equal to 75 000 Btu/hr) electric resistance, and heat pump water heaters list Energ\
Factor For large gas storage water heaters (rated input of greater than 75,000 Btu/hr), list Rated Input Recovery Efficiency and Slandbv Loss
For instantaneous gas water heaters, list rated input and recovery efficiencies
SPECIAL FEATURES and MODELING ASSUMPTIONS (Add extra sheets if necessary)
Including Thermal Mass (thermal mass type, covering, thickness, and description)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24 Parts 1 and 6 of
\ the California Code of Regulations, and the administrative regulations to implement them This certificate hai bven signed bv the
individual with overall design responsibility When this certificate of compliance is submitted for a single building, plan to be built in
, multiple orientations, any shading feature that is varied is indicated in the Special Features / Remarks section
Designer or Owner (per Business and Professions Code)
Name |*l-^tV^ c ^
Title/Firm
Address
(flate)
1 Enforcement Agency
I Name
Title
Agency
\ Telephone
Documentation Author
Name
Title/Firm
Address
Telephone
(signature)(date)
(signature/stamp)(date)
July 1,1999
NAILING All nailing shall comply with Table 23-1-Q below
UBC TABLE 23-l-Q - NAILING SCHEDULE
CONNECTION
1 Joist to Sill or girder, Toenail
2 Bridging to joist toenail each end
3 1 X6" subftoor or less to each joist, face nail
4 Wider than 1"x6" subfloor to each joist face nail
5 2" subfloor to joist or girder, blind and face nail
6 Sole plate to joist or blocking, typical face nail
Sole plate to joist or blocking, at braced wall panel
7 Top plate to stud, end nail
8 Stud to sole plate
9 Double studs, face nail
10 Doubled top plates, typical face nail
Double top plates, lap splice
1 1 Blocking between joist or rafters to top plate, toenail
12 Rim joist to top plate, toenail
13 Top plates, laps and intersections , face nail
14 Continuous header, two pieces
15 Ceiling joists to plate, toenail
16 Continuous header to stud, toenail
17 Ceiling joists, laps over partitions, face nail
18 Ceiling joists parallel to rafters, face nail
19 Rafter to plate, toenail
20 1 ' brace to each stud and ptate, face nail
21 1" x 8" sheathing or less to each bearing, face nail
22 Wider than 1" x 8" sheathing to each bearing, face nail
23 Built-up comer studs
24 Built up girder and beams
25 2 x planks
26 Wood structural panels and particleboard 2
Subfloor, roof and wall sheathing (to framing)
Vi" and less
19/32"-3/4"
7/8" - 1"
1 1/8 " - 1 V."
Combination subfloor undertayment (to framing)
%" and less
7/8" -r
1 1/8" - 1 %"
27 Panel siding (to framing)
Ys" or less
5/8"
28 Fiberboard sheathing 7
%"
25/32"
29 Interior paneling
3/8"
NAILING,
3-8d
2-8d
2-8d
3-8d
2-1 6d
16d at 16"oc
3-1 6d per 16"
2-16d
4-8d, toenail or 2-16d, end nail
16d @ 24" o c
16d@ 16" oc
8-16d
3-8d
8d @ 6" o c
2-16d
16d @ 16" o c along each edge
3-8d
4-8d
3-16d
3-16d
3-8d
2-8d
3-8d
3-8d
16d@24"oc
20d @ 32" o c at top and bottom and staggered 2-20d at
ends and at each splice
2-1 6d at each beanng
6d3
8d4or6dB
8d3
10d«or8ds
6d5
8d5
10d, or8d5
6dfl
8d6
No, 1 1 ga a
6d4
No 16gafl
No 1 1 ga fl
8d4
No 16 ga9
4d10
6dn
1 Common or box nails may be used except where otherwise stated2 Nails spaced 6" o c at edges, 12" o c at intermediate supports except 6" at all supports where spans are 48" or more
For nailing of wood struc'—-al p._..c! and particle board diaphragms and snear walls refer to Section 2314 3 Nails for wall
sheathing may be common, box, or casing
3 Common or deformed shank
* Common
5 Deformed shank6 Corrosion resistant siding or casing nails conforming to the requirements of Section 2304 3
7Fasteners spaced 3" o c at extenor edges and 6" o c at intermediate supports
8 Corrosion resistant roofing nails with 7/16" diameter head and 1 YS length for YS sheathing and 1 y/1 length for 25/32"
sheathing conforming to the requirements of Section 2304 3
9 Corrosion resistant staples with 7/16" crown and 1 1/8" length for '/a" sheathing and 1 1/=' length for 25/32" sheathing
conforming to the requirements of Section 2304 310 Panel supports at 16"o c [ 20" if strength axis m the long direction of the panel, unless otherwise marked] Casing or
finish nails spaced 6" on panel edges, 12" at intermediate supports11 Panel supports at 24" Casing or finish nails spaced 6" on panel edges, 12" at intermediate supports