HomeMy WebLinkAbout1720 BRUCE RD; ; CB154106; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
01-12-2016 Residential Permit Permit No: CB154106
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
1720 BRUCE RD CBAD
RESDNTL Sub Type: RAD
Lot#: 0
Valuation:
Occupancy Group:
# Dwelling Units:
2073603900
$116,767.00 Constuction Type: 58
Reference #:
Status: ISSUED
Applied: 11/25/2015
Entered By: RMA
Plan Approved: 01/12/2016
Issued: 01/12/2016
Inspect Area:
Structure Type:
Bedrooms:
0
0 Bathrooms: 0
Orig PC#: Plan Check #:
Project Title: MITCHELL RES-ADD 700 SF MASTER
BEDROOM & BATH @ 1ST FLOOR, CONVERT THE ENTIRE 78 SF OF
PREVIOUS MASTER CLOSET TO A LAUNDRY ROOM @ 2ND FLOOR
Applicant:
QUINN MCCARRON
STE D
2091 LAS PALMAS DR
CARLSBAD CA 92011
760 438-2963
Building Permit
Add'l Building Permit Fee
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park in Lieu Fee
Park Fee
LFM Fee
Bridge Fee
Other Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee
HMP Fee
Pot. Water Con. Fee
Meter Size
Add'l Pot. Water Con. Fee
Reel. Water Con. Fee
Green Bldg Stands (SB1473) Fee
Green Bldg Stands Plan Chk Fee
$686.41
$0.00
$480.49
$0.00
$0.00
$15.18
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$5.00
$0.00
Total Fees: $1,372.91 Total Payments to Date:
FINAL
Inspector: Date:
Owner:
MITCHELL DON W&SUSAN N TRS
1720 BRUCE RD
CARLSBAD CA 92008
Meter Size
Add'l Reel. Water Con. Fee
Meter Fee
SDCWA Fee
CFD Payoff Fee
PFF (31 05540)
PFF (4305540)
License Tax (3104193)
License Tax (4304193)
Traffic Impact Fee (3105541)
Traffic Impact Fee (4305541)
Sidewalk Fee
PLUMBING TOTAL
ELECTRICAL TOTAL
MECHANICAL TOTAL
Housing Impact Fee
Housing lnLieu Fee
Housing Credit Fee
Master Drainage Fee
Sewer Fee
Additional Fees
Fire Sprinkler Fees
TOTAL PERMIT FEES
$1,372.91 Balance Due:
Clearance:
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$88.00
$46.00
$51.83
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$1,372.91
$0.00
NOTICE: Please take NOTICE that approval of your prqect includes the "lrrpooition'' a fees, dedications, reservations, or other exactions hereafter <Xllledively
referred to as "fees/exactions." You have 00 days fran the date this perrrit was issued to protest irrpooitim of these fees/exactions. If you protest them, you rrust
folloothe protest proca:lures set forth in C:OVemrrent COOe Sectim 60020(a), ard file the protest and any other requira:l inforrratim v.Ath the Oty r-.Aanager for
ptJCESSing in acrordancev.Ath Carlsbad M.Jnidpal COOe Sectim 3.32.030. Failure to tirrelyfolloothat proca:lurev.AII tar any sutrequent legal actimtoattack,
revievv, set aside, void, or annul their irrpooition.
You are hereby FURTI-£R NOTIRED that your right to protest the specified fees/exactions OOES NOT JIPA.. Y to water and seNSr oonnedim fees and capacity
dlanges, nor planning, zoning, grading or other sinilar application pu;essing or service fees in oonnedim v.Ath this rrojed. NOR DOES IT JIPA.. Y to any
feesle ions of \1\hich have · ousi been iven a NOTICE sinilar to this or o 'Ahich the statute of linitations has ·ousl otherv.Ase ·ra:l.
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
01-12-2016
Storm Water Pollution Prevention Plan {SWPPP) Permit
Permit No:SW150452
Job Address:
Permit Type:
1720 BRUCE RD CBAD
SWPPP Status:
Parcel No: 2073603900 Lot#: 0 Applied:
Reference #:
CB#: CB154106
Project Title: MITCHELL RES-ADDITION @ 1ST FL
Applicant:
QUINN MCCARRON
760 438-2963
Emergency Contact:
QUINN MCCARRON
760 438-2963
SWPPP Plan Check
SWPPP Inspections
Additional Fees
TOTAL PERMIT FEES
Entered By:
Issued:
Inspect Area:
Tier:
Priority:
Owner:
MITCHELL DON W&SUSAN N TRS
1720 BRUCE RD
CARLSBAD CA 92008
ISSUED
11/25/2015
RMA
01/12/2016
1
M
$54.00
$228.00
$0.00
$282.00
Total Fees: $282.00 Total Payments To Date: $282.00 Balance Due:
FINAL APPR VAL
DATE~ CLEARANCE -----SIGNATURE~
$0.00
,,
EHE •vLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0PLANNING 0 ENGINEERING BUILDING OFIRE 0HEALTH 0HAZMATIAPCD
Plan Check No. C/3/~ Lj / ~ ,£
City of Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008 Est.Value //~ 7/7'
Ph: 760-602-2719 Fax: 760-602-8558 Plan Ck. J?eposit Carlsbad email: building@carlsbadca.gov fiA-www.carlsbadca.gov Date 1//;tf//:..r--lswPPP ii5D452l
JOB ADDRESS SUITE#/SPACE#/UNIT# IAPN 1720 BRUCE ROAD CARLSBAD, CA 92008 207 -360 -39 -00
CT/PROJECT # I LOT,-I PHASE# I # OF ~NITS I# BEDROOMS #BATHROOMS I TENANT BUSINESS NAME I CONSTR. 1YPE I occ. GROUP
DESCRIPTION OF WORK:-/iiCiude Square Feet of Affected Area(s)
THE PROJECT IS TO CREATE A 700 S.F. +/·MASTER SUITE ONE STORY ADDITION ON THE MAIN FLOOR & REMODEL
THE EXISTING MASTER CLOSET INTO AN UPSTAIRS LAUNDRY ROOM {78.0 S.F.). THE EXTERIOR STYLE AND FINISHES
SHALL BE SIMILAR TO THE EXISTING RESIDENCE.
EXISTING USE I PROPOSED USE I GARAGE (SF) PATIOS (SF) I DECKS (SF) FIREPLACE I AIR CONDITIONING I FIRE SPRINKLERS
RESIDENTIAL RESIDENTIAL 597 98 YES0ft NoD YEs[!]NoO YEsONoO
APPLICANT NAME QUINN McCARRON PROPERTY OWNER NAME DON & SUE MITCHELL Prlnarv Contact
ADDRESS ADDRESS
2091 LAS PALMAS DRIVE SUITED 1720 BRUCE ROAD
CITY STATE ZIP CITY STATE ZIP
CARLSBAD CA 92011 CARLSBAD CA 92008
PHONE I FAX PHONE I FAX 760 438 2963 760 729 6445
EMAIL EMAIL
QUINN@BGIARCHITECT.COM DWSNMTC@PACBELL.NET
DESIGN PROFESSIONAL SAME AS ABOVE CONTRACTOR BUS. NAME
ADDRESS ADDRESS
CITY STATE ZIP CITY STATE ZIP
PHONE I FAX PHONE I FAX
EMAIL EMAIL
[STATE LIC. # STATE LIC.# I CLASS I CI1Y BUS. LIC.#
(Sec. 7031.5 Busmess and Profess1ons Code: Any C1ty or County wh1ch requ1res a permit to construct, alter, 1mprove, demolish or repair any structure, pnor to 1ts issuance, also requires the
applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the
Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a
civil penalty of not more than five hundred dollars {$500}).
Workers' Compensation Declaration: I hereby affirm under penalty of peryury one of the following declarations:
0 I have and will maintain a certificate of consent to self·insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. 0 I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. Policy No. Expiration Date ________ _
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars {&100,000), in
addition to the cost of compensation, damages as provided for in Section 3706 of the Labor code, interest and attorney's fees .
.2$ CONTRACTOR SIGNATURE 0AGENT DATE
I hereby affirm that I am exempt from Contractor's License Law for the following reason: 0 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
/sale. If, however, the building or improvement is sold within one year of completion, the owner·builder will have the burden of proving that he did not build or improve for the purpose of sale).
[2] I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. DYes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
/ ~ENT DATE .2$ PROPERTY OWNER SIGNATURE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? 0 Yes 0 No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 Yes 0 No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 Yes 0 No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permH is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the date of such permit or if the building or work by such permit is suspended or abandoned at any time after the work is commenced a period of 180 days (Section 106.4.4 Uniform Building Code).
Ji5 APPLICANT'S SIGNATURE DATE
Inspection List
Permit#: CB154106 Type: RESDNTL RAD
Date __ _ lnsp~-t!~J:lltem lnl;lpector
06/22/2016 89 Final Combo AEK
06/22/2016 89 Final Combo
06/20/2016 89 Final Combo
06/20/2016 89 Final Combo AEK
05/10/2016 17 Interior Lath/Drywall AEK
05/1 0/2016 27 Shower Pan/Roman Tubs AEK
04/20/2016 18 Exterior Lath/Drywall AEK
04/18/2016 17 Interior Lath/Drywall AEK
04/15/2016 17 Interior Lath/Drywall AEK
04/11/2016 16 Insulation AEK
04/04/2016 23 Gas/T esURepairs AEK
04/04/2016 84 Rough Combo AEK
03/25/2016 15 Roof/Reroof AEK
03/10/2016 66 Grout AEK
03/04/2016 11 Ftg/Foundation/Piers AEK
03/02/2016 21 Underground/Under Floor AEK
03/02/2016 31 Underground/Conduit-Wirin AEK
Thursday, June 23, 2016
Act
Fl
Rl
Rl
co
AP
AP
AP
AP
PA
AP
AP
AP
AP
AP
AP
AP
AP
MITCHELL RES-ADD 700 SF MASTER
BEDROOM & BATH@ 1ST FLOOR, CONV
Comments
AM PLEASE
AM PLEASE
SEE NOTICE/lAC/ EXT DOOR LIGHT
SHOWER LATH
BATHROOM//CLOSET//ENTRYWAY
2/SD1
Page 1 of 1
(City of
Carlsbad
SPECIAL INSPECTION
AGREEMENT
B-45
Develq2_ment Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
In accordance with Chapter 17 of the California Building Code the following must be completed when work being performed
requires special inspection, structural observation and construction material testing.
Project Address:
A. THIS SECTION MUST BE COMPLETED BY THE PROPERTY OWNER/AUTHORIZED AGENT. Please check if you are Owner-Builder
D. (If you checked as owner-builder you must also complete Section 8 of this agreement.) ;'\ s
• Name: (Please pnnt) tdQi-J._QQ.., , . \)£ f"\JJJ 1-lf:k_L ____ ~··········
(f,rst) (M.I.l (Las~)
, Mailing Address: ____ L220 B£.ul..£_KoP\Q __ (._AJ?-LS.Bl.01 C£J.._92.DQS_ __
Email:_ _____ .D W 5 1'-J ()J_ LC@ P~cBE L L~_j __ U_S
I am: ,..'rroperty Owner DProperty Owner's Agent of Record DArchitect of Record DEngineer of Record
State of California Registration Numbec______ ··-----------Expiration Date: _____ _
AGREEMENT: I, the undersigned, declare under penalty of perjury under the laws of the State of California, that I have read,
understand, acknowledge and promise to comply with the City of Carlsbad requirements for special inspections, structural
observatio , construction ·a rials testing and off-site fabrication of building com onents, as prescribed in the statement of
special insp ctions noted on proved plans and, as required by the Califor ·a ilding Code.
, Signatu · { 2, 1 ~ ~Jfo
B. CONTRACTOR'S STATEMENT OF RESPONSIBILITY (07 CBC, Ch 17, Section 1706). This section must be completed by the
contractor I builder I owner-builder.
Contractor's Company Name: ______ _ _ ___ .. _______ Please check if you are Owner-BuildE!r .'J
Name: (Please print) ·----·
{First) (MI) (Lasq
Mailing Address: _
Email: ______ _ .. ~--------Phone: ___
State of California Contractor's License Number: ______ .. . .. _________ Expiration Date:
• I acknowledge and, am aware, of special requirements contained in the statement of special inspections noted on
the approved plans;
• I acknowledge that control will be exercised to obtain conformance with the construction documents approved by the
building official;
• I will have in-place procedures for exercising control within our (the contractor's) organization, for the method and
frequency of reporting and the distribution of the reports; and
• I certify that I will have a qualified person within our (the contractor's} organization to exercise such control.
• I will provide a final report I letter in compliance with CBC Section 1704.1.2 prior to requesting final
inspection.
Signature: ---~-~------__________ Date: ____ ...
8-45 Page 1 of 1 Rev. 0811'1
Structural Inspections LLC
*SPECIAL INSPECTION SERVICES*
P.O. Box 2415 El Cajon, CA 92021
Cell: (619) 770-9559 • Fax (619) 588-5955
Inspection Report
l " (,} l Page: ____ , of Report#:'-------
Permit #:__,I'--' '-=-~-~-~·==IIJI"----4-'-.,L/_{_J l_· __ _
File#:------------------
~ ~ I Engineer: __ -'~'-: ----"----l-1-.. rf:-r _1·"_·' _i_l_w-'-· l_· --:;------------!{ ~
DSA#: ___________________________ __
Contractor:_,.T_>·_:A._ •. _''----"$'_1 •_~_. ___ ;_. _<::_'' ,_.,~· __ >_ ... _ ... _./_':*_.:··-----------Other:'-------------------
INSPECTION MATERIAL SAMPLING QTY MATERIAL DESCRIPTION INSPECTION CHECKLIST
--Structural Steel --H.S.Bolts ---H.S. Bolts ,~' Plans/Specs
--Masonry --Prisms --Cone. PSI --Clearances
Concrete Mortar/Grout Grout PSI Positions --------
Fireproofing Cone. Cylinders Mortar PSI "' ---- --
__ Sizes
"'""""' Epoxy Fireproof ~"""Steel Laps ------
Other: Other: Elect./Wire Consolidation --------
--Other: --Other: --Fireproof --Torque Ft. Lbs:
Other: Other: ,,.~,.,.. Other: "X·)# /'7 .,.. •.. Othe"t lf''OJ" ----1':~~ _ ... _
/.r~.~rt' ~--· ~ "
Other: Other: ..... ;'"""''' Other: ''/11\·•"1 Other: ------
CERTIFICATION OF COMPLIANCE: All reported work, unless otherwise noted, complies with approved plans, specifications and applicable sections
of the building codes. This report covers the locations of the work inspected and does not constitute opinion or project control.
I hereby certify that I have observed to the best of my knowledge all of the above reported work unless otherwise noted. I have found this work to
,
' \
comply with the approved plans, specifications, and applicable sections of the governing building lawt~·-··"''":: ..... ;.,.""?~·;,;,,~.~p !'"' ~ r
Inspector: MARIO BATTAGLIA Cert: 350 / ,, · .3 ;~1 (1
Signature Date
Approved By: ____________________ _
Project Superintendent
.
I
EsGil Corporation
In (}!artnersfzip witfz government for c.BuiCtfing Safety
DATE: DEC.08,2015
JURISDICTION: CARLSBAD
PLAN CHECK NO.: 15-4106 SET: I
PROJECT ADDRESS: 1720 BRUCE ROAD
PROJECT NAME: SFR-One-Story Addition & Remodel for Mitchell
D
D
D
D
D
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewi·th is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil Corporation staff did not advise the applicant that the plan check has been completed.
EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:_ ~ Telephone#:
Date contacted: ~ ( ) Email:
Mail Te~ep oni\A-.J/x In rson L}~
REMARKS: : Rtnfb"ve"NbT FOR CONSTRUCTION" stamp on . A-9, M2 & CG-1 of plans; ~On Sht. E-1,
show a W gas ine from the meter to instantaneous water he:~plete the Special Inspection Agreement
From for Epoxy anchors, per detail 8/801. c:J ..
By: ALI SADRE, S.E. Comments: Due to oversized footings, no soils report was deemed necessary.
EsGil Corporation
D GA D EJ D MB D PC 11/30
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
[DO NOT PAY-THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: CARLSBAD
PREPARED BY: ALI SADRE, S.E.
BUILDING ADDRESS: 1720 BRUCE ROAD
BUILDING OCCUPANCY: R3/U; V-B
BUILDING AREA Valuation
PORTION (Sq. Ft.) Multiplier
LIVING ADD 684
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code CB By Ordinance
Bldg. Permit Fee by Ordinance
Plan Check Fee by_O_rd_ina_nc_e __ ... __,j
Type of Review: Complete Review
D Repetitive Fee ---~ Repeats
D Other
0 Hourly
EsGil Fee
PLAN CHECK NO.: 15-4106
DATE: DEC.08,2015
Reg. VALUE ($)
Mod.
116,767
$686.411
$446.171
D Structural Only
1------11 Hr @ • $384.391
Comments: In addition to the above fee, an additionalfee of $43 is due (l/2 hour@ $86/hr,~forthe
CaiGreen review.
Sheet 1 of 1
macvalue.doc +
DATE:
PLAN CHECK
REVIEW
TRANSMITTAL
PROJECT NAME: MITCHEl
Community & Economic
Development Department
1635 Faraday Avenue
Carlsbad CA 92008
www.carlsbadca.gov
PROJECT ID:CB154106
PLAN CHECK NO: 1 SET#: 1 ADDRESS: APN:
VALUATION: SCOPE OF WORK: 700SF ADD AND
D
Remarks:
This plan check review is complete and has been APPROVED by:
LAND DEVELOPMENT ENGINEERING DIVISION
Final Inspection by Construction Management & Inspection Division is required: Yes No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to:
Linda Ontiveros
760-602-2773
VaiRay Nelson
760-602-27 41
VaiRay.Marshall@carlsbadca.gov
MITCHEl PlAN CHECK NO# 1
conform permit
or have intentionally left
1. SITE PLAN
Provide a fully dimensioned site plan drawn to scale. Show:
North arrow
Existing & proposed structures
Existing street improvements
Property lines (show all dimensions)
Easements
Right-of-way width & adjacent streets
Driveway widths
Existing or proposed sewer lateral
Existing or proposed water service
Submit on signed approved plans:
DWG No.
Show on site plan:
Drainage patterns and proposed site elevations. Show all high points.
Building pad surface drainage must maintain a minimum slope of one percent towards an adjoining
street or an approved drainage course.
ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive drainage of 2% to swale
5' away from building".
• Existing & proposed slopes and topography
·I Size, location, alignment of existing or proposed sewer and water service(s) that serves the project.
Each unit requires a separate service; however, second dwelling units and apartment complexes are an
exception.
Sewer and water laterals should not be located within proposed driveways, per standards.
Include on title sheet:
Site address
Assessor's parcel number
Legal description/lot number
For commercial/industrial buildings and tenant improvement projects, include: total building
square footage with the square footage for each different use, existing sewer permits
showing square footage of different uses (manufacturing, warehouse, office, etc.) previously
approved.
Show all existing use of SF and new proposed use of SF.
Example:
Tenant improvement for 3500 SF of warehouse to 3500 SF of office.
Lot/Map No.: MAP 10870 LOT 2
Subdivision/Tract: CT 82-21
Reference No(s):
E-36 Page 2 of 6 REV 6/01/12
MITCHEL
E-36
ADDITION PLAN CHECK NO# 1
2. DISCRETIONARY APPROVAL COMPLIANCE
Project does not comply with the following engineering conditions of approval for project no.:
3. DEDICATION REQUIREMENTS
Dedication for all street rights-of-way adjacent to the building site and any storm drain or
utility easements on the building site is required for all new buildings and for remodels with a
value at or exceeding $ 24 000 00 , pursuant to Carlsbad Municipal Code Section 18.40.030.
Dedication required as follows:
4. IMPROVEMENT REQUIREMENTS
All needed public improvements upon and adjacent to the building site must be constructed
at time of building construction whenever the value of the construction exceeds
$120.000.00, pursuant to Carlsbad Municipal Code Section 18.40.040.
Public improvements required as follows:
Construction of the public improvements must be deferred pursuant to Carlsbad
Municipal Code Section 18.40. Please submit a recent property title report or current grant
deed on the property and processing fee, so we may prepare the necessary Neighborhood
Improvement Agreement. This agreement must be signed, notarized and
approved by the city prior to issuance of a building permit.
1 Future public improvements required as follows:
Page 3 of 6 REV 6/01112
MITCHEl
E-36
ADDiTION PlAN CHECK NO# 1
5. GRADING PERMIT REQUIREMENTS
The conditions that require a grading permit are found in Section 15.16 of the Municipal
Code.
r ·~!Inadequate information available on site plan to make a determination on grading "',<<W"'~J requirements. Include accurate grading quantities in cubic yards (cut, fill, import, export and
remedial). This information must be included on the plans. If no grading is proposed
write: "NO GRADING"
Grading Permit required. NOTE: The grading permit must be issued and rough grading
approval obtained prior to issuance of a building permit.
Graded Pad Certification required. (Note: Pad certification may be required even if a grading
permit is not required.) All required documentation must be provided to your Engineering
Construction Inspector The inspector will then
provide the engineering counter with a release for the building permit.
No grading permit required.
Minor Grading Permit required. See additional comments for project-specific requirements.
6. MISCELLANEOUS PERMITS
:RIGHT -OF-WAY PERMIT is required to do work in city right-of-way and/or private work
adjacent to the public right-of-way. Types of work include, but are not limited to: street
improvements, tree trimming, driveway construction, tying into public storm drain, sewer and
water utilities.
Right-of-way permit required for:
Page 4 of6 REV 6/01112
MITCHEl
E-36
ADDITiON PLAN CHECK NO#
7. STORM WATER
Construction Compliance
Project Threat Assessment Form complete.
Enclosed Project Threat Assessment Form incomplete.
Requires Tier 1 Storm Water Pollution Prevention Plan (E-29). Please complete attached form
and return (SW15~452 )
Requires Tier 2 Storm Water Pollution Prevention Plan. Requires submittal of Tier 2
SWPPP, payment of processing fee and review by city.
Post-Development {SUSMP) Compliance
Storm Water Standards Questionnaire.
1 Project is subject to Standard Storm Water Requirements. See city Standard Urban
Storm Water Management Plan (SUSMP) for reference.
Indicate areas of impervious surfaces (patios, walkway, etc. ) and pervious areas (landscaping).
Project needs to incorporate low impact development strategies throughout in one or
more of the following ways:
Rainwater harvesting (rain barrels or cistern)
Vegetated Roof
Bio-retentions cell/rain garden
Pervious pavemenUpavers
Flow-through planter/vegetated or rock drip line
Vegetated swales or rock infiltration swales
Downspouts disconnect and discharge over landscape
; Other:
Page 5 of 6 REV 6/01112
MITCHEL
Attachments:
E-36
ADDITION PLAN CHECK NO# 1
8. WATER METER REVIEW
Domestic (potable) Use
What size meter is required?
Where a residential unit is required to have an automatic fire
extinguishing system, the minimum meter size shall be a 1" meter.
NOTE: the connection fee, SDCWA system capacity charge and the
water treatment capacity charge will be based on the size of the meter
necessary to meet the water use requirements.
For residential units the 'minimum size meter shall be 5/8", except where
9. FEES
the residential unit is larger than 3,500 square feet or on a lot larger than
one quarter (1/4) acre where the meter size shall be%".
Required fees have been entered in building permit.
Drainage fee applicable
Added square feet
Added square footage in last two years?
Permit No.
Permit No.
Project built after 1980
Impervious surface> 50%
Impact unconstructed facility
yes
yes
yes
yes
no
no
no
Fire sprinklers required
Upgrade
No fees required
yes
no (is addition over 150' from center line)
~]no
10. ADDITIONAL COMMENTS
Engineering Application Storm Water Form Right-of-Way Application/Info. Reference Documents
Page 6 of 6 REV 6/01112
Fee Calculation Worksheet
ENGINEERING DIVISION
Prepared by: Date: GEO DATA: LFMZ: I B&T:
Address: Bldg. Permit#:
Fees Update by: Date: Fees Update by: Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq.Ft./Units EDU's:
Types of Use:
Types of Use:
Types of Use:
Sq.Ft./Units
Sq.Ft./Units
Sq.Ft./Units
ADT CALCULATIONS: List types and square footages for all uses.
EDU's:
EDU's:
EDU's:
Types of Use: Sq.Ft./Units ADT's:
Types of Use:
Types of Use:
Types of Use:
FEES REQUIRED:
Sq.Ft.!Units
Sq.Ft./Units
Sq.Ft./Units
ADT's:
ADT's:
ADT's:
Within CFD: []YES (no bridge & thoroughfare fee in District #1, reduces Traffic Impact Fee) NO
1. PARK-IN-LIEU FEE:;"JNW QUADRANT NE QUADRANT []SE QUADRANT !]W QUADRANT
ADT'S/UNITS: I X FEE/ADT: I =$
2.TRAFFIC IMPACT FEE:
ADT'S/UNITS: I X
3. BRIDGE & THOROUGHFARE FEE:
(USE SANDAG)ADT'S/UNITS I X
4. FACILITIES MANAGEMENT FEE
FEE/ADT:
DIST. #1
FEE/ADT:
ZONE:
ADT'S/UNITS: I X FEE/SQ.FT./UNIT:
5. SEWER FEE
EDU's
BENEFIT AREA:
EDU's
6. DRAINAGE FEES:
ACRES:
7. POTABLE WATER FEES:
I X FEE/EDU:
IX
PLDA:
IX
FEE/EDU:
L~.~]HIGH
FEE/AC:
I=$
DIST.#2
I=$
I=$
I=$
I=$
MEDIUM
I=$
UNITS CODE CONN. FEE METER FEE SDCWA FEE
DIST.#3
TOTAL
~---------------------------------------------------------------------,
«~#t'\
~ CITY OF
CARLSBAD
STORM WATER
COMPLIANCE
ASSESSMENT
B-24
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
I am applying t~the City of Carlsbad for the following type(s) of construction permit:
[I Building Permit 0 Right-of-Way Permit
0 My project is categorically EXEMPT from
the requirement to prepare a storm water
pollution prevention plan (SWPPP) because it
only requires issuance of one or more of the
following permit types:
Electrical
Fire Additional
Fire Alarm
Fixed Systems
Mechanical
Mobile Home
Plumbing
Project Storm Water Threat Assessment Criteria*
Patio/Deck
Photo Voltaic
Re-Roofing
Sign
Spa-Factory
Sprinkler
Water Discharge
No Threat Assessment Criteria
0 My project qualifies as NO THREAT and is exempt from the requirement to prepare a storm water pollution prevention plan (SWPPP) because
it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Construction SWPPP Tier
Level. My project does not meet any of the High, Moderate or Low Threat criteria described below.
Tier 1 • Low Threat Assessment Criteria
-· )6 My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt permit type (See list above) and the project
./" meets one or more of the following criteria:
• Results in some soil disturbance; and/or
• Includes outdoor construction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling).
Tier 2 • Moderate Threat Assessment Criteria
0 My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria:
• Project requires a grading plan pursuant to the Carlsbad Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code); or,
• Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria:
• Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or
• Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or
• Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or
• Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30).
Tier 3 • Significant Threat Assessment Criteria
0 My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or
0 My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, refueling and maintenance areas: or,
0 My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant
potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s).
I certify to the best of my knowledge that the above
checked statements are true and correct. I understand
and acknowledge that even though this project does
not require preparation of a construction SWPP, I must
still adhere to, and at all times during construction
activities for the permit type(s) check above comply
with the storm water best management practices
pursuant to Title 15 of the Carlsbad Municipal Code
and to City Standards.
*The City Engineer may authorize minor variances from the Storm
Water Threat Assessment Criteria in special circumstances where it
can be shown that a lesser or higher Construction SWPPP Tier Level is
warranted.
B-24
Project Address:
17 2-0 &oct RD C4 ~sBAD CA
Assessor Parcel No.
Title:
City Concurrence:
,,YES IJ NO 0
Page 1 of 1 Rev.03/09
£ ~~' ~ CITY OF
CARLSBAD
CONSTRUCTION THREAT
ASSESSMENT WORKSHEET FOR
DETERMINATION OF PROJECT'S
PERCEIVED THREAT TO
STORM WATER QUALITY
E-33
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
Construction Perceived
Threat to SWPPPTier Construction Threat Assessment Criteria* Storm Water Level Quality
Tier 3-High Construction Threat Assessment Criteria
D Project site is 50 acres or more and grading will occur during the rainy season
D Project site is 1 acre or more in size and is located within the Buena Vista or Agua Hedionda
Lagoon watershed, inside or within 200 feet of an environmentally sensitive area (ESA) or
discharges directly to an ESA High D Soil at site is moderately to highly erosive (defined as having a predominance of soils with
Tier3 USDA-NRCS Erosion factors kt greater than or equal to 0.4)
D Site slope is 5 to 1 or steeper
D Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1
D
through April 30).
Owner/contractor received a Storm Water Notice of Violation within past two years
Tier 3 -Medium Construction Threat Assessment Criteria Medium D All projects not meeting Tier 3 High Construction Threat Assessment Criteria
Tier 2 High Construction Threat Assessment Criteria
D Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, inside or
within 200 feet of an environmentally sensitive area (ESA) or discharges directly to an ESA
D Soil at site is moderately to highly erosive (defined as having a predominance of soils with
USDA-NRCS Erosion factors kt greater than or equal to 0.4) High
D Site slope is 5 to 1 or steeper Tier2 D Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1
through April 30).
D Owner/contractor received a Storm Water Notice of Violation within past two years
D Site results in one half acre or more of soil disturbance
Tier 2 -Medium Construction Threat Assessment Criteria Medium D All projects not meeting Tier 2 High Construction Threat Assessment Criteria
Tier 1 -Medium lnsQection Threat Assessment Criteria
0 Project is located within the Buena Vista or Agua Hedionda Lagoon watershed, within or
directly adjacent to an environmentally sensitive area (ESA) or discharges directly to an ESA
D Soil at site is moderately to highly erosive (defined as having a predominance of soils with /
USDA-NRCS Erosion factors kt greater than or equal to 0.4)
' Medium
Tier 1 ~ Site slope is !? to 1 or steeper
Construction is initiated during the rainy season or will extend into the rainy season (Oct. 1
' through April 30). ··
D Owner/contractor received a Storm Water Notice of Violation within past two years
D Site results in one half acre or more of soil disturbance
Tier 1 -Low lnsQection Threat Assessment Criteria Low D All projects not meeting Tier 1 Medium Construction Threat Assessment Criteria
Exempt -Not Applicable -Exempt
*The c1ty engmeer may authonze mmor vanances from the construction threat assessment cntena 1n spec1al circumstances
where it can be shown that a lesser or higher amount of storm water compliance inspection is warranted in the opinion of
the city engineer
E-33 Page 1 of 1 REV 4/30/10
-· '
W CITY OF
CARLSBAD
STORM WATER
STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
To address post-development pollutants that may be generated from development projects, the City requires that new development and
significant redevelopment priority projects incorporate Permanent Storm Water Best Management Practices (BMP's) into the project
design per the City's Standard Urban Stormwater Management Plan (SUSMP). To view the SUSMP, refer to the Engineering Standards
(Volume 4, Chapter 2) at www.carlsbadca.gov/standards.
Initially this questionnaire must be completed by the applicant in advance of submitting for a development application (subdivision,
discretionary permits and/or construction permits). The results of the questionnaire determine the level of storm water standards that
must be applied to a proposed development or redevelopment project. Depending on the outcome, your project will either be subject to
'Standard Stormwater Requirements' or be subject to additional criteria called 'Priority Development Project Requirements'. Many
aspects of project site design are dependent upon the storm water standards applied to a project.
Your responses to the questionnaire represent an initial assessment of the proposed project conditions and impacts. City staff has
responsibility for making the final assessment after submission of the development application. If staff determines that the questionnaire
was incorrectly filled out and is subject to more stringent storm water standards than initially assessed by you, this will result in the return
of the development application as incomplete. In this case, please make the changes to the questionnaire and resubmit to the City.
If you are unsure about the meaning of a question or need help in determining how to respond to one or more of the questions, please
seek assistance from Land Development Engineering staff.
A separate completed and signed questionnaire must be submitted for each new development application submission. Only one
completed and signed questionnaire is required when multiple development applications for the same project are submitted concurrently.
In addition to this questionnaire, you must also complete, sign and submit a Project Threat Assessment Form with construction permits
for the project.
Please start by completing Step 1 and follow the instructions. When completed, sign the form at the end and submit this with your
application to the city.
To determine if your project is a priority development project, please answer the following questions:
1. Is your project LIMITED TO constructing new or retrofitting paved sidewalks, bicycle lanes or trails that meet
the following criteria: (1) Designed and constructed to direct storm water runoff to adjacent vegetated areas, or
other non-erodible permeable areas; OR (2) designed and constructed to be hydraulically disconnected from
paved streets or roads; OR (3) designed and constructed with permeable pavements or surfaces in
accordance with USEPA Green Streets
2. Is your project LIMITED TO retrofitting or redeveloping existing paved al , or roads that are
designed and constructed in accordance with the USEPA Green
YES NO
I
/
If you answered "yes" to one or more of the above questions, then your project is NOT a priority development project and therefore is
NOT subject to the storm water criteria required for priority development projects. Go to step 4, mark the last box stating "my
project does not meet PDP requirements" and complete applicant information.
answered "no" to both 2.
E-34 Page 1 of 3 Effective 6/27113
~
~~ W CITY OF
CARLSBAD
STORM WATER
STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
To determine if your project is a priority development project, please answer the following questions:
1. Is your project a new development that creates 10,000 square feet or more of impervious surfaces collectively
over the entire project site? This includes commercial, industrial, residential, mixed-use, and public
develo ment ro 'ects on ublic or rivate land.
2. Is your project creating or replacing 5,000 square feet or more of impervious surface collectively over the entire
project site on an existing site of 10,000 square feet or more of impervious surface? This includes commercial,
industrial, residential, mixed-use, and ublic develo ment ro ·ects on ublic or rivate land.
3. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a restaurant? A restaurant is a facility that sells prepared
foods and drinks for consumption, including stationary lunch counters and refreshment stands selling prepared
foods and drinks for immediate con sum tion.
4. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a hillside development project? A hillside development
project includes development on any natural slope that is twenty-five percent or greater.
5. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a parking lot. A parking lot is a land area or facility for the
tern ora parkin or storage of motor vehicles used personal/ for business or for commerce.
6. Is your project a new or redevelopment project that creates 5,000 square feet or more of impervious surface
collectively over the entire project site and supports a street, road, highway freeway or driveway? A street,
road, highway, freeway or driveway is any paved impervious surface used for the transportation of
automobiles, trucks, motorc cles, and other vehicles.
7. Is your project a new or redevelopment project that creates or replaces 2,500 square feet or more of
impervious surface collectively over the entire site, and discharges directly to an Environmentally Sensitive
Area (ESA)? "Discharging Directly to" includes flow that is conveyed overland a distance of 200 feet or less
from the project to the ESA, or conveyed in a pipe or open channel any distance as an isolated flow from the
ro·ect to the ESA i.e. not commin les with flows from ad'acent lands.*
8. Is your project a new development that supports an automotive repair shop? An automotive repair shop is a
facility that is categorized in any one of the following Standard Industrial Classification (SIC) codes: 5013,
5014, 5541, 7532-7534, or 7536-7539.
9. Is your project a new development that supports a retail gasoline outlet (RGO)? This category includes RGO's
that meet the following criteria: (a) 5,000 square feet or more or (b) a project Average Daily Traffic (ADT) of
100 or more vehicles erda .
1 O.ls your project a new or redevelopment project that results in the disturbance of one or more acres of land and
are expected to generate pollutants post construction?
11.1s your project located within 200 feet of the Pacific Ocean and (1) creates 2,500 square feet or more of
impervious surface or {2) increases impervious surface on the property by more than 10%?
YES NO
I
I
I
I
I
.I
I
I
I
If you answered "yes" to one or more of the above questions, you ARE a priority development project and are therefore subject to
implementing structural Best Management Practices (BMP's) in addition to implementing Standard Storm Water Requirements such
as source control and low impact development BMP's. A Storm Water Management Plan (SWMP) must be submitted with your
application(s) for development. Go to step 3 for redevelopment projects. For new projects, go to step 4 at the end of this
questionnaire, check the "my project meets PDP requirements" box and complete applicant information.
If you answered "no" to all of the above questions, you ARE NOT a priority development project and are therefore subject to
implementing only Standard Storm Water Requirements such as source control and low impact development BMP's required for all
development projects. A Storm Water Management Plan (SWMP) is not required with your application(s) for development. Go to step
4 at the end of this questionnaire, check the "my project does not meet PDP requirements" box and complete applicant
information.
E-34 Page 2 of 3 Effective 6/27/13
~ «-¥ CITY OF
CARLSBAD
STORM WATER
STANDARDS
QUESTIONNAIRE
E-34
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
Does the redevelopment project nt of impervious surface in an amount of less than
50% of the surface area of the
If you answered "yes," the structural BMP's required for Priority Development Projects apply only to the creation or replacement of
impervious surface and not the entire development. Go to step 4, check the "my project meets PDP requirements" box and
complete applicant information.
If you answered "no," the structural BMP's required for Priority Development Projects apply to the entire development. Go to step 4,
check the " meets PDP rements" box and icant information.
'
My project meets PRIORITY DEVELOPMENT PROJECT (PDP) requirements and must comply with additional stormwater
criteria per the SUSMP and I understand I must prepare a Storm Water Management Plan for submittal at time of application.
I understand flow control (hydromodification) requirements may apply to my project. Refer to SUSMP for details.
My project does not meet PDP requirements and must only comply with STANDARD STORMWATER REQUIREMENTS per
the SUSMP. As part of these requirements, I will incorporate low impact development strategies throughout my project.
Applicant Information and Signature Box
Accessor's Parcel Number(s): 1o7 :3GO '3CCOO
Applic;ant Title: '""' .ARL+fl "( [ G (
Date: { -i I 2-3/JofS
I I
This Box for City Use Only
City Concurrence: NO
By:
Project ID:
*Environmentally Sensitive Areas include but are not limited to all Clean Water Act Section 303(d) impaired water bodies; areas
designated as Areas of Special Biological Significance by the State Water Resources Control Board (Water Quality Control Plan for the
San Diego Basin (1994) and amendments); water bodies designated with the RARE beneficial use by the State Water Resources
Control Board (Water Quality Control Plan for the San Diego Basin (1994) and amendments); areas designated as preserves or their
quivalent under the Multi Species Conservation Program within the Cities and County of San Diego; and any other equivalent
environmentally sensitive areas which have been identified by the Copermittees.
E-34 Page 3 of 3 Effective 6/27/13
~ CITY OF
CARLSBAD
STORM WATER COMPLIANCE FORM
TIER 1 CONSTRUCTION SWPPP
E-29
STORM WATER COMPLIANCE CERTIFICATE
<~' My project is not in a category of permit types exempt from the Construction
SWPPP requirements
<~' My project is not located inside or within 200 feet of an environmentally
sensitive area with a significant potential for contributing pollutants to nearby
receiving waters by way of storm water runoff or non-storm water
discharge(s).
<~' My project does not require a grading plan pursuant to the Carlsbad
Grading Ordinance (Chapter 15.16 of the Carlsbad Municipal Code)
<~' My project will not result in 2,500 square feet or more of soils disturbance
including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas that meets
one or more of the additional following criteria:
• located within 200 feet of an environmentally sensitive area or the
Pacific Ocean; and/or,
• disturbed area is located on a slope with a grade at or exceeding 5
horizontal to 1 vertical; and/or
• disturbed area is located along or within 30 feet of a storm drain inlet, an
open drainage channel or watercourse; and/or
• construction will be initiated during the rainy season or will extend into
the rainy season (Oct. 1 through April 30).
I CERTIFY TO THE BEST OF MY KNOWLEDGE THAT ALL OF THE ABOVE
CHECKED STATEMENTS ARE TRUE AND CORRECT. I AM SUBMITTING
FOR CITY APPROVAL A TIER 1 CONSTRUCTION SWPPP PREPARED IN
ACCORDANCE WITH THE REQUIREMENTS OF CITY STANDARDS.
I UNDERSTAND AND ACKNOWLEDGE THAT I MUST: (1) IMPLEMENT BEST
MANAGEMENT PRACTICES (BMPS) DURING CONSTRUCTION ACTIVITIES
TO THE MAXIMUM EXTENT PRACTICABLE TO MINIMIZE THE
MOBILIZATION OF POLLUTANTS SUCH AS SEDIMENT AND TO MINIMIZE
THE EXPOSURE OF STORM WATER TO CONSTRUCTION RELATED
POLLUTANTS; AND, (2) ADHERE TO, AND AT ALL TIMES, COMPLY WITH
THIS CITY APPROVED TIER 1 CONSTRUCTION SWPPP THROUGHOUT THE
DURATION OF THE CONSTRUCTION ACTIVITIES UNTIL THE
CONSTRUCTION W. O~K IS COMPLETE AND APPROVED BY THE CITY OF
CARLS)MID\ II
L'
E (SIGNATURE)
Ji L2! .---rirFP
E-29
STORM WATER POLLUTION PREVENTION NOTES
1. ALL NECESSARY EQUIPMENT AND MATERIALS
SHALL BE AVAILABLE ON SITE TO FACILITATE
RAPID INSTALLATION OF EROSION AND
SEDIMENT CONTROL BMPS WHEN RAIN IS
EMINENT.
2. THE OWNER/CONTRACTOR SHALL RESTORE
ALL EROSION CONTROL DEVICES TO
WORKING ORDER TO THE SATISFACTION OF
THE CITY ENGINEER AFTER EACH RUN-OFF
PRODUCING RAINFALL.
3. THE OWNER/CONTRACTOR SHALL INSTALL
ADDITIONAL EROSION CONTROL MEASURES
AS MAY BE REQUIRED BY THE CITY
ENGINEERING OR BUILDING INSPECTOR DUE
TO UNCOMPLETED GRADING OPERATIONS OR
UNFORESEEN CIRCUMSTANCES WHICH MAY
ARISE.
4. ALL REMOVABLE PROTECTIVE DEVICES SHALL
BE IN PLACE AT THE END OF EACH WORKING
DAY WHEN THE FIVE (5) DAY RAIN
PROBABILITY FORECAST EXCEEDS FORTY
PERCENT (40%). SILT AND OTHER DEBRIS
SHALL BE REMOVED AFTER EACH RAINFALL.
5. ALL GRAVEL BAGS SHALL BE BURLAP TYPE
WITH 3/41NCH MINIMUM AGGREGATE.
6. ADEQUATE EROSION AND SEDIMENT
CONTROL AND PERIMETER PROTECTION BEST
MANAGEMENT PRACTICE MEASURES MUST BE
INSTALLED AND MAINTAINED.
SPECIAL NOTES
Page 1 of 3
Development Services
Land Development Engineering
1635 Faraday Avenue
760-602-2750
www.carlsbadca.gov
PROJECT INFORMATION
Site Address: lUCE ROAD CARLSBAD,~)
Assessor's Parcel Number: '2...07 '3G.D Je( DO
Project ID: S:VJ 15' (} '10
Construction Permit No.: CJ/2"4/pt
Estimated Construction Start Date ..5./i-
Project Duration _y Months
Emergency Contact:
Name: Guw/J }1CCiRJ?.o(\)
24 hour Phone: 7 {;;o ~ :3~ '2..CCf:>3 i" IZ '1
Perceived Threat to Storm Water Quality
0 Medium
J(Low
If medium box is checked, must attach a site plan
sheet showing proposed work area and location
of proposed structural BMPs
For City Use Only
Approved By: .,_ •..J~"'="-.... "="'='\. , £ •
Date: •u / c..1~J 1 1 ,
REV 4/30/10
~
... :
~
J
.•
Erosion Control 5 d" t C t 1 BMP T~ac~in~ Non-Storm Water Waste Management and Materials
BMPs e lmen °~ ro s ,.., :~;~ Management BMPs Pollution Control BMPs
' \
\ § 6 § c c
rn -g tl tl c g' ~ ~ -g ~ "t:l -ro 2 2 .Q ·-.g> a. ro (]) ffi (]) co -c ~ E 0> t.... a; ...... -ro -g .!:: ·s ~ Cl u; Q)
8 M P . ~ g' c ~ a. (])" c .5!1 "2 ~ rn ~ ;:: ·t:: 1::: O" (]) ro § ro ii) est anagement ract1ce oes ·-ro. ~ rn ro Ill ·c. t:: -0 $" 0 (]) 0 (]) UJ > ffi ., s ro-
(BMP) Description 7 ~ fi gj (J) .5 ~ E rn OJ al OJ ci:'l -~ (.) 6) (.) ~ "t:l -~ ]! -g 00> ~ ~ :ij 2 rn S ~
·-:::1 .>< (]) ~ ~ c ro -ro 3: .5 Cl .._ § "t:l UJ "t:l >. o rn ffi > ro n ::J (]) > !(! :::1 (]) E x ~ 0 OJ o c (]) 0 fi ~ (J) E ro o :;::; :!! Cis :!! ~ 0 ~ ~) ~-(]) (]) . c ro l ro ·::: !!!. ~ > .g ai a: (1.) "C ca <» <U E ~ a> ...... ::J .o o = C/) = > t.... .::::: _, ::C o ·c .. i:: 't: J:t' a. . > '-"-c o o € .5 a. u. ·-u Qj > (]) :::1 "t:l E (]) :0 (]) :0 "t:l (]) t5 .5 :IT ro ·-ro (]) (]) u -"t:l. '! ro u ct
Q)" 0 ca e ..Q ~ ~ ~ :e ~ ~ ~ ffi .s e s c, .£9 ~ C6 ~ ro .Q 0 -&5 ~ 10 ro .e :a ~ j ~ 6 ~ 0 S UJO (J) (J) (J) (.) u. (.') (J)> (J) (J)Q. (J)E (1)0:: sa. a.Ci a. >U ~ ~ (J) (J) (J)~ I~ (.):::::!
CASQA Designation 7 1'--00 0) ~ /.;:'\ C') "f LO <0 1'--00 0 cr~"·, C\1 ~ C') 1'--00 .~ ..... , C\1 C') r"f-. _./LO· <0 .4 ! U U U ~(.), uJ 1i uJ UJ uJ uJ uJ uJ '7 ·. & ' & rh rh rh rh I ~~ i ~ ··~ (~ \. ( ~ . ~ / ~ .
UJ UJ UJ (j{) (/) (/) (/) (/) (/) (/) UJ I-I-z z z z ' >J > > :'i > \\ > j > > ' Construction Activity UJ J) (J) ... / '<:., > > \:: _) \:'V > > J
LK Grading/Soil Disturbance · Y:: I>< j IX:: Trenching/Excavation 'y !><
s~c~rn~ ,
Drilling/Boring \
Concrete/Asphalt Saw 0
cutting
~< Concrete flatwork ··. ></
Paving
i>, ConduiUPipe Installation ~.>-...:-
. < Stucco/Mortar Work ->-:::...... \
"<. Waste Disposal -l
Staging/Lay Down Area .... ,
Equipment Maintenance
and Fueling
Hazardous Substance
Use/Storage
Dewatering y
X Site Access Across Dirt jx,
Other (list): · ,
Instructions: Begin by reviewing the list of construction activities and checking the box to the left of any activity that will occur during the proposed construction. Add any other activity descriptions in the
blank activity description boxes provided for that purpose and place a check in the box immediately to the left of the added activity description. For each activity descrribed, pick one or more best
management practices (BMPs) from the list located along the top of the form. Then place an X in the box at the place where the activity row int~rsects with the BMP column. Do this for each activity that was
checked off and for each of the selected BMPs selected from the list. For Example-If the project includes site access across dirt, then check the box to the left of "Site Access Across Dirt". Then review
the list for something that applies such as "Stabilized Construction Ingress/Egress" under Tracking Control. Follow along the "Site Access Across Dirt" row until you get to the "Stabilized Construction
Ingress/Egress" column and place an X in the box where the two meet. As another example say the project included a stockpile that you intend to cover with a plastic sheet. Since plastic sheeting is not on
the list of BMPs, then write in "Cover with Plastic" in the blank column under the heading Erosion Control BMPs. Then place an X in the box where the "Stockpiling" row intersects the new "Cover with
Plastic" column.
To learn more about what each BMP description means, you may wish to review the BMP Reference Handout prepared to assist applicants in the selection of appropriate Best Management Practice
measures. The reference also explains the California Stormwater Quality Association (CASQA) designation and how to apply the various selected BMPs to a project.
'·-1. .
E-29 Page 2 of 3 REV 4/30/10
~-~.,!
PLANNING DIVISION
BUILDING PLAN CHECK
APPROVAL
P-29
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.e:ov
DATE: 12/1/15 PROJECT NAME: MASTER BEDROOM, BATH, & CLOSET ADDITION
PROJECT ID:
PLAN CHECK NO: CB154106 SET#: ADDRESS: 1720 BRUCE RD APN:
[gj This plan check review is complete and has been APPROVED by the PLANNING
Division.
By: GINA RUIZ
A Final Inspection by the PLANNING Division is required DYes [gl No
You may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance of a building permit.
Resubmitted plans should include corrections from all divisions.
D This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check APPROVAL has been sent to: QUINN@BGIARCHITECT.COM
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
760-602-4624
Chris.Sexton@carlsbadca.gov
Gina Ruiz
760-602-4675
Gina.Ruiz@carlsbadca.gov
D Veronica Morones
760-602-4619
Veronica.Morones@carlsbadca.gov
VaiRay Marshall
760-602-2741
VaiRay.Marshall@carlsbadca.gov
Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
760-602-4663
Gregory.Ryan@carlsbadca.gov
Cindy Wong
760-602-4662
Cynthia.Wong@carlsbadca.gov
Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
Remarks: CCC EXEMPTION LETTER PROVIDED 6-15-0286-X, HEIGHT=13.5',
SETBACKS: SIDE=10' & 28', FRONT=32', REAR=42', COVERAGE=16.8%
STATE OF CALIFORNIA--THE NATURAL RESOURCES AGENCY EDMUND G. BROWN, JR., Governor
CALIFORNIA COASTAL COMMISSION
SAN DIEGO AREA
7575 METROPOLITAN DRIVE, SUITE 103
SAN DIEGO, CA 92108-4402
Sent via email 9/09/2015 -ES
(619) 767-2370
EXEMPTION LETTER
DATE: September 9, 2015
NAME: Quinn McCarron
2091 Las Palmas Drive
Carlsbad, CA 92011
LOCATION: ------"---17,__,2=0---!oB=ru=c=e"--'R=o=a=d,_, C=ar=ls=b=ad=----
6-15-0286-X
RJECEIVEo
NOV 2 5 2015
CITYOFc
BUILDING ARL.SBAD
DIVISION
PROJECT: Construction of an approximately 700 sg. ft. addition to an existing 2,400
sq. ft. single family residence on a 15,800 sq. ft. lot.
This is to certify that this location and/or proposed project has been reviewed by the staff
of the Coastal Commission. A coastal development permit is not necessary for the
reasons checked below.
D The site is not located within the coastal zone as established by the California Coastal
Act of 1976, as amended.
D The proposed development is included in Categorical Exclusion No. -----adopted by the California Coastal Commission.
D The proposed development is judged to be repair or maintenance activity not resulting
in an addition to or enlargement or expansion of the object of such activities (Section
30610(d) of the Coastal Act).
C8J The proposed development is an improvement to an existing single-family residence
(Section 30610(a) of the Coastal Act) and not located in the area between the sea and
the first public road or within 300 feet of the inland extent of any beach (whichever is
greater) (Section 13250(b)(4) ofthe 14 Cal. Admin. Code.
D The proposed development is an improvement to an existing single-family residence
and is located in the area between the sea and the first public road or within 300 feet
of the inland extent of any beach (whichever is greater) but is not a) an increase of
10% or more of internal floor area, b) an increase in height over 10%, or c) a
significant non-attached structure (Sections 30610(a) of the Coastal Act and Section
13250(b )( 4) of Administrative Regulations).
D The proposed development is an interior modification to an existing use with no
change in the density or intensity of use (Section 30106 of the Coastal Act).
(over)
~
0 0
Q tt
0
0 w
::;.ii!l'
...
Page2
D The proposed development involves the installation, testing and placement in service
of a necessary utility connection between an existing service facility and development
approved in accordance with coastal development permit requirements, pursuant to
Coastal Act Section 30610(±).
D The proposed development is an improvement to a structure other than a single-
family residence or public works facility and is not subject to a permit requirement
(Section 13253 of Administrative Regulations).
D The proposed development is the rebuilding of a structure, other than a public works
facility, destroyed by natural disaster. The replacement conforms to all of the
requirements of Coastal Act Section 30610(g).
D Other:
Please be advised that only the project described above is exempt from the permit
requirements of the Coastal Act. Any change in the above project may cause it to lose its
exempt status. This certification is based on information provided by the recipient of this
letter. If, at a later date, this information is found to be incorrect or incomplete, this letter
will become invalid, and any development occurring at that time must cease until a
coastal development permit is obtained.
Sincerely,
By: Eric Stevens
Title: Coastal Planner
~ « ¥ CITY OF
PLUMBING,
ELECTRICAL,
MECHANICAL
WORKSHEET
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
Building@carlsbadca.gov CARLSBAD 8-18
Project Address: 1720 8rLIX£ RD. CAets'BA D,CA Permit No.: CJ; /5 LJ/ g 6
Information provided below refers to wor~ being done on the above mentioned permit only.
This form must be completed and returned to the Building Division before the permit can be issued.
Building Dept. Fax: (760) 602-8558
Number of new or relocated fixtures, tlraps, or floor drains....................................................... 4
New building sewer line? ......................................................................................... Yes __ No-r
Number of new roof drains? ............................................................................................................... _Q_
Install/alter water line?......................................................................................................................... 'Yt: 5
Number of new water heaters? ......................................................................................................... _I _
Number of new, relocated or replaced gas outlets? .................................................................... _ L
Number of new hose bibs? .................................................................................................................. _Q__
Residential Permits:
New/expanded service: Numi}er of new amps:
Minor Remodel only: Yes_·_v_ No __
Commercial/Industrial:
Tenant Improvement: Number of existing amps involved in this project: _._N:u.A-=----
Number of new amps involved in this project: ___,_N-'-'-'1\,__ __
New Construction: Amps per Panel:
Single Phase ............................................................... Number of new amperes _______ _
Three Phase ................................................................. Number of new amperes _______ _
Three Phase 480 ........................................................ Number of new amperes _______ _
Number of new furnaces, A/C, or heat pumps? ......................................................... 7 ................ _/_
New or relocated duct wor~? .......................................................................... Yes V No __ _
Number of new fireplaces? ................................................................................................................. _Q_
Number of new exhaust fans? ............................................................................................................ _j_
Relocate/install vent?............................................................................................................................ '0
Number of new exhaust hoods? ........................................................................................................ V
Number of new boilers or compressors? ........................................................... Number of HP 0
B-18 Page 1 of 1 Rev. 03/09