Loading...
HomeMy WebLinkAbout1721 BRUCE RD; ; CB010316; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Pool Permit Permit No:CB010316 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: POOL Status: ISSUED Parcel No: 2071006300 Lot #: 0 Applied: 01/25/2001 Valuation: $24,575.00 Construction Type: NEW Entered By: MDP Reference #: Plan Approved: 04/06/2001 Issued: 04/06/2001 Project Title: MASON RESIDENCE-FIREPLACE IN Inspect Area: AR 1721 BRUCE RD CBAD REAR YARD & 650 SF POOL AND SPA Applicant: PERMIT MASTERS P 0 834 SAN JUAN CAPISTRANO CA 888 708-8686 Owner: PROCTOR GARY N&BETH 431 1 SEA BRIGHT DR 3279 06/27/01 NO2 91 $2 CARLSBAD CA 92008 CGP 3s 4: Total Fees: $404.52 Total Payments To Date: $366.1 0 Balance Due: $38.42 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Electrical Fee Plumbing Fee Strong Motion Fee Renewal Fee Add'l Renewal Fee Other Building Fee Additional Fees TOTAL PERMIT FEES $215.19 $0.00 $1 39.87 $0.00 $20.00 $27.00 $2.46 $0.00 $0.00 $0.00 $0.00 $404.52 FINAL APPROVAL Inspector: & Date: ~-, Clearance: NOTICE: Please take NOTICE that approval of your project includes the 'Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "feedexactions." You have 90 days from the date this permit was issued to protest imposition of these feeslexactions. If you protest them, you must follow the protest procedures set forb in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your tight to protest the specified feeslexactions DOES NOT APPLY to water and sewer connection fees and capactiy changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any feedexactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired. 04/06/200 1 Job Address: Permit Type: Parcel No: Start Date: Insurance Expire: Liability Insurance: Reference#: Location: Project Title: Description: City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Right of Way Permit Permit No: RW010049 1721 BRUCE RD CBAD ROW Subtype: MINOR Status: ISSUED 2071006300 Lot #: 0 Applied: 02/06/2001 Est Complete Date: Issued: 04/06/2001 0 I /02/2002 Traffic Control Plan: Y Expired: 10/06/2001 Y GOP: Entered By: JJ CB010316 1721 BRUCE RD PROCTOR RESIDENCE POOL/FIREPLACE/BBQ Applicant: OCEAN RIDGE LANDSCAPE INC STE D 201 1 S. EL CAMINO REAL SAN CLEMENTE CA 92672 949-369-931 8 Total Fees: $230.00 Total Payments To Date: $0.00 Balance Due: $230.00 Permit Fee Additional Permit Fee Other Additional Fees TOTAL PERMIT FEES $230.00 $0.00 $0.00 $0.00 $230.00 This permit may be revoked by the City Engineer if it is deemed that inadequate progress is being made towards the completion of the work or if the work does not meet City Standards. The applicant may be billed for the cost of any corrective work that the City must perform. Permit Release Date Released YOU MUST CALL UNDERGROUND SERVICE ALERT (1-800-422-4133) TWO WORKING DAYS PRIOR TO WORK. UNDERGROUND SERVICE ALERT NO. IF ANY EXCAVATION OR BORING IS DONE. . THIS PERMIT IS INVALID WITHOUT THIS NUMBER I PERMIT APPLICATION CITY 'OF CARLSBAD BUILDING DEPARTMENT 1635 Faraday Ave., Carlsbad, CA 92008 FOR OFFICE USE ONLY PLAN CHECK NO. a\ '3 \b - EST. VAL. Plan Ck. Deposit Validated By Date /%7di - (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance. also reouires the anolicant for such oermit to file a sioned statement that he is licensed oursuant to the orovisions of the Contractor's License Law - - -. - - . __ --_ - - - r- -- -- ._ .._ . .. .. [Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code1 or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$5001). State License # Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: 0 of the work for which this permit is issued. 0 issued. My worker's compensation insurance carrier and policy number are: Insurance Company Policy No. Expiration Date (THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [$I001 OR LESS) I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance I have and will maintain workers' compensation. as required by Section 3700 of the Labor Code, for the performance of the work for which this permit IS at in the performance of the work for which this permit is issued, 1 shall not employ any person in any manner so as n Laws of California. er to criminal penalties and civil fines up to one hundred 3706 of the Labor code, interest and attorney's fees. DATE "/--&- b/ tractor's License Law for the following reason: 0 I, as owner o e property 6f6y employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). 0 I, as owner of the property. am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractorls) licensed pursuant to the Contractor's License Law). (Sec. 7044, Busi P ess and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does 0 1. 2. 3. 4. am exempt under Section personally plan to provide the major labor and materials for construction of the proposed property improvement. 0 YES (have I have not) signed an application for a building permit for the proposed work. have contracted with the following person (firm) to provide the proposed construction (include name I address I phone number I contractors license number): Business and Professions Code for this reason: UNO plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone number I contractors license number): 5. of work): PROPERTY OWNER SIGNATURE DATE I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone number I type ardous materials registration form or risk managemen program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? 0 YES 0 NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? 0 YES 0 NO IF ANY OF THE ANSWERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 8 I LENDER'S NAME LENDER'S ADDRESS 0 YES 0 NO e work for which this permit is issued (Sec. 3097(i) C~vil Code). I certify that I have read the application and state that the above information is correct and that the information on the plans IS accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representatives of the Citv of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is permit or if the building or work authorized by s ch per t IS suspended or abandoned at any time after the work IS Uniform Building Code) APPLICANT'S SIGNATURE DATE !bTb! Applicant PINK: Finance City of Carlsbad Bldg Inspection Request For: 09/24/200 1 Permi# CB010316 Inspector Assignment: GG Title: MASON RESIDENCE-FIREPLACE IN Description: REAR YARD & 650 SF POOL AND SPA Type: POOL Sub Type: Job Address: 1721 BRUCE RD Suite: Lot 0 Location : APPLICANT PERMIT MASTERS Owner: PROCTOR GARY N&BETH Remarks: Total Time: CD Description 59 Final Pool Phone: 7607291 767 Inspector: Requested By: BETH MASON Entered By: KAREN Associated PCRs InsDection Historv Date Description Act lnsp Comments 07/30/2001 51 Excav/Steel/Bonding/Fence WC GG 07/30/2001 55 FencelPre-Plaster AP GG 06/29/2001 I I Ftg/Foundation/Piers AP GG @FIREPLACE 06/29/2001 12 SteeVBond Beam AP GG 05/29/2001 62 Steel/Bond Beam AP AR 05/18/2001 61 Footing AP AR 04/19/2001 23 GasResVRepairs AP AR 04/19/2001 51 Excav/Steel/Bonding/Fence AP AR fencing ok 04/19/2001 52 Underground Plumbing AP AR 0411 9/2001 53 ElectriclConduitMliring AP AR BUILDING PLANCHECK CHECKLIST POOLS BUILDING PLANCHECK NUMBER: CB BUILDING ADDRESS: ce/ PROJECT DESCRIPTION: Pool ASSESSORS PARCEL NUMBER: a7 -/m 63 ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore, any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in wspension of permit to build. ,r ATTACHMENTS Grading Permit Application Grading Permit Checklist ' Rig h t-of-Way Permit Application Right-of-way Permit Submittal Checklist and Information Sheet ENIAL of deficiencies corrections to plans or specifications for compliance with applicable Submit corrected plans this office for review. By: Date: By: Date: By: Date: ENGINEERING DEPT. CONTACT PERSON NAME: Kathleen M. Farmer City of Carlsbad ADDRESS: 1635 Faraday Avenue Carlsbad. CA 92009 PHONE: (760) 602-2741 1635 Faraday Avenue Carlsbad, CA 92008-7314 (760) 602-2720 FAX (760) 602-8562 @ BUILDING PLANCHECK CHECKLIST - POOLS SITE PLAN @ { Provide a fully dimensioned site plan drawn to scale. Show: Structures asements 0 2. Show on site plan: ndicate what will happen with soil excavated from pool area Retaining Walls (location and height) Drainage Patterns Existing & Proposed Slopes Note: If excavated soil is not to be removed from property but regraded on site, show proposed elevations and slopes. If any portion of retaining walls are over 4’ in height, a separate permit is required. Retaining Wall Permit CB Applied for Approved 3. Include on title sheet: A. Site Address B. Assessor’s Parcel Number C. Legal Description D. Grading Quantities Cut Fill ImpoNExport P 0 CI 4. Project does not comply with the following Engineering Conditions of approval for Project NO. Conditions were complied with by: Date: GRADING PERMIT REQUIREMENTS The conditions that invoke the need for grading permit are found in Section 11.06.030 of the Municipal code. 0 P Cl 5a. Inadequate information available on Site Plan to make a determination on grading Fequirements. Include accurate grading quantities (cut, fill, import, export). cl Q 0 5b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted together with the completed application form attached. Note: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit Page 1 of 2 .. c 1STJ 2NDJ 3RDJ CI. CI CI 5c. A Grading Permit has been applied for: PE2 DWG Grading Inspector sign off by: Date: 0 5d. No Grading Permit required. MISCELLANEOUS PERMITS 6. D A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way and/or private work adjacent tot he public Right-of-way. A separate Right-of-way issued by the Engineering Department is required for the following: Please complete attached Right-of-way application form and return to the Engineering Department together with the requirements on the attached Right- of-Way checklist, at the time of resubmittal. Right-of-way Permit and Pool Building Permit will be issued simultaneously. 0 D D 7. Remarks Page 2 of 2 LEGAL DESCRIPTION A. P. N. 20 7-1 00-54 PARCEL A OF PARCEL MAP NO. I2243 FILED IN DE60 COUNTY, JULY 16,1982 A. P. N. 20 7-1 00-55 THE QFFKE OF THE COUNTY RECOR~R OF SAN P.&#?CEL B OF PARCEL MAP NO. 12243 FILED IN THE OFFICE OF TM COUNTY RECORD~R OF SAN DKGo COUNTY, JULY 16,1982 A.P.N. 207-100-56 PARCEL C OF PARCEL MAP NO. 12243, FILED IN TtE OFFIE OF THE COUNTY REC0I;IDER OF SAN DEGO COUNTY, JULY 16, E982 A.P.N. 207-360-43 LOT 6 OF MAP NO. 10870 FILE0 N ThE OFFICE OF TNE COUUTY RECORdR OF SAN DIEGO COUN - TY FiZMU4RY 29, 1984 &LL IN THE CITY OF CARLSBAD, CbUNTY OF SAN OEGQ STATE OF CALIFORNIA. US48 Of ~hR##@S THE BASES OF BEARINGS FOR THIS MAP IS THE tV#?Ttl€hSTERLY SlDELlNE OF PARK DRIVE PER PARCEL MAP NO. 12243, LE., N 46'08'27' W. LEGEND a FOW lf2' STEEL PIN WITH CAP LA 4088 P.M 12293, UNLESS OTMERWSE NOTED. FQWM 2' IRW PIPE WITH TAG L.S. 4088 PER P.M E2E43. SURVEYORS STATEMENT THIS ADJUSTMENT PLAT WAS PREPARED BY ME Oh UNDER MY DIRECTION ON APRIL 23, /9%7. EXPIRES JUNE 30, 1988 W8AW RICHARD 8. HI1 L L.S. 4088 R.B.HILL 8 ASSOC., INC. 514 E. VISTA WAY VISTA, CA. 92084 16191 941 -22 71 3774 SKYLINE ROAD CARLSBAD, CA. 92008 (61 9) 93 -3224 725 GRAND AVE. CARLSBAD, CA. 92008 (619) 434-1013 dZ'1-C GILBERT RA Y FILES SI8 BRIGH TON COURT (619) 727- 760J VISTA, CA. 920a3 0 SET 1/2' X 18' STEEL PIW WITH CAP L.S. 4088 INDICA TES NEW LOT LINE INDICATES OLD LOT LINE INDICA TES OPEN SPACE EASEMENT BOUNDARY -- ---- LIIILILLI ACCESS RIGHTS TO BE RELINQUISHED NOTE8 THE FOLLQWG EASEMENTS ARE GENERAL EASE- BE PLOTTED ON PLA T. 73 WTW NO LOCATION SET FORTH AND CANNOT t. TO W. G. KRCKHOFF CO. FOR UTILITIES, REC. 4!3#4& BK. 1484. PG. 147, O.R. 2. fOT$Sk- TELE. 60. FOR COUM. STRUCTURES, eC, 5j@2$& AS FILE NO. 81-146825, OJ?. 3. r0 MC DiDWW FOR UTILITES, REC. 4/5/84 AS -r FILE NO. 614-l24@29. O.R. I, 2, 8 3 AFFECTS LOT 6 OF MAP 10870 SHEET - I OF - 2 SHEETS ccc mmm hhh 000 PLANNING DEPARTMENT BUILDING PLAN CHECK REVIEW CHECKLIST Plan Check No. CB Planner Greg Fisher APN: a07 -100 - b 3 Type of Project & Use:bo\ /Sp A- Zoning: E\ - \!OO General Plan: El ~ CFD finlnirt) # Date of participation: Remaining net dev acres: 0 \ -A \I 9 Address 17 2\ .35YLk e d* Phone (760) 602-4629 Net Project Density: DU/AC Facilities Management Zone: Circle One - (For non-residential development: Type of land used created by this permit: 1 Legend: Item Complete 0 Item Incomplete - Needs your action TYPE Environmental Review Required: YES NO - DATE OF COMPLETION: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval: Discretionary Action Required: YES NO TYPE APPROVAL/RESO. NO. DATE PROJECT NO. OTHER RELATED CASES: Compliance with conditions or approval? If not, state conditions which require action. Conditions of Approval: Coastal Zone Assessment/Compliance Project site located in Coastal Zone? YES >c NO- If California Coastal Commission Authority: Contact them at - 31 11 Camino Del Rio North, Suite 200, San Diego CA 92108-1725; (619) 521-8036 Determine status (Coastal Permit Required or Exempt): Coastal Permit Determination Form already completed? YES NO If NO, complete Coastal Permit Determination Form now. Coastal Permit Determination Log #: Follow-Up Actions: 1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum Floor Plans). 2) Complete Coastal Permit Determination Log as needed. CA Coastal Commission Authority? YES NO- H:\ADMIN\COUNTER\BldgPlnchkRevChklst 0 000 UDU OOU 000 000 NO lnclusionary Housing Fee required: YES - (Effective date of lnclusionary Housing Ordinance - May 21, 1993.) Data Entry Completed? YES NO IA/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct Housing Y/N, Enter Fee, UPDATE!) Site Plan: 1. Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width, dimensional setbacks and existing topographical lines. 2. Provide legal description of property and assessor’s parcel number. 9 Zoning: 1. 2. 3. 4. 5. Setbacks : Front: Required Interior Side: Required Street Side: Required Rear: Required Accessory structure setbacks: Front: Required Interior Side: Required Street Side: Required Rear: Required Structure separation: Required Lot Coverage: Required Height: Required Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Shown Parking: Spaces Required Guest Spaces Required Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER ($F DATE \-X’-O \ H:\ADMIN\COUNTER\BldgPlnchkRevChklst woo(1 frame Combustible material Above roof BOTTOM REINF. EACH WAY FREE STANDING SQUARE HEIGHT-FI'. FOOTING "W" (min.) 11' 4'4" I Anchorage ~ ZLer Fasten to Bolts Embedment into chimney 1 3' 1 5' 17' Footing Thickness Width Outside air intake 4'4" 4154 5'4" 544 5'4" 544 6" (152 mm) min. to fireplace opening. 12" (305 mm) from opening when material projecting more than I/B for each 1" (25 mm). S I i/g6" X l"(4.8 mm by 25 mm) 12" (305 mm) hooked around outer bar w/6" (152 mm) ext. 2" x 4" (51 mm by 102 mm) ties crossing a min. of 4 joists Two '/I" (13 mm) diameter 12" (305 mm) min. VERTICAL FL NOTE: *See Figure 5 for letter references. Steel reinforcement shown is required in Seismic Zones 2, 3 and 4. See "Chimneys, Fireplaces arid Barbecues" for additional information. lyu~ of iidmx OT me on udr side of firebox. +whsn outride air intake vcn(~ am required, pi& either om in GABLE END OPEN I ALTERNATE FOUNDATION SCHEDULE FOR A ONE STORY FREE STANDING FIREPLACE (Soil Bearing lo00 psf max.) ANCHOR TIE CONNECTIONREQUIREI The above dnforcement requirement v (2.54 m) above anchor tie. (Check local building cc Chimneys of excessive height, weight, i should be designed in accordance with sound engi imposed by wind or earthquake. Many times, when a chimney extend! intermediate lateral support or tie may be placed chimney and tied back to the roof HEIGHT OF SMAU CHIMNEY APPROX. 22" x 30" CHIMNEY Nail 2" x 4"ru~a Bolttieto 2"x4"nnum to rrftas or 'oids 244 " bolts 2-H " bolts 10-16d Mih thissheet except no anchor tie connections at roof or ceiling are req& but are recommended in seismic areas.