Loading...
HomeMy WebLinkAbout1723 CATALPA RD; ; CB163098; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit 08-12-2016 Permit No: CB163098 Building Inspection Request Line (760) 602-2725 Job Address:1723 CATALPA RD CBAD Permit Type:PME Status:ISSUED Parcel No:2155120800 Lot*0 Applied:08/12/2016 Entered By:JMA Reference #:Plan Approved:08/12/2016 PC #:Issued:08/12/2016 Inspect Area: Project Title:DEZONIA: REPLACE FAU/ ADD AC W/ ELECTRIC Applicant:Owner: SHERLOCK HEATING & AIR CONDITIONING INC DEZONIA FAMILY TRUST 02-21-12 STE 104 2880 SCOTT ST 1723 CATALPA RD VISTA CA 92081 -8560 CARLSBAD CA 92011 760-295-5014 Plumbing Fees $0.00 Electrical Fees $38.00 Mechanical Fees $163.00 Other PME Fees $0.00 TOTAL PERMIT FEES $201.00 Total Fees:$201.00 Total Payments To Date:$201.00 Balance Due:$0.00 FINAL APPROVAL_ Inspector:i)A1 Date:-Clearance: NOTICE Reese take CE that approval d your project indudes the "Irrpcsition" of fees, decications, reservations, or other exactions hereafter collectively referred to as lees/exactions."You have 93 days from the date this permit was issued to protest imposition of these fees/emotions.If you protest them you must fdlcw the protest procedures set forth in Government Code Section 66020(a), and file the protest and ayother required information with the QtyManager for processing in accordance with Carlsbad Muridpal rnri.Sedion 3.32.030.Failtle to timely fdlcw that procedure will bar any subsequent legal action to attack, review, set aside, void, or acrd their irrposition. You are tr.. eby RRTHERNOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, gracing or othersirrilxapplication processing or service fees in comedion with this dried.NOR DOES ITAPPLYto any feeslexactions of Mich vcu have previously been civen a NOTICE sirrila-to this, or as to which the statute of lirritations has previously otherwise expired. ,THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE:OPLANNING DENGINEERING 0 BUILDING EIFIRE EJHEALTH El HAZMATIAPCD Building Permit Application Plan Check No.C13((0 3061 (6 (1_City of 1635 Faraday Ave., Carlsbad, CA 92008 Est. Value Ph: 760-602-2719 Fax: 760-602-8558Carlsbademail: building@carlsbadca.gov Plan Ck. Deposit •www.carlsbadca.gov Date yli 21 6 SWPPP JOB ADDRESS 1 1 41.1 C Ce*O3A7Ck•% SUITEVSPACEVUNIT•APN -- CT/PROJECT #LOT #PHASE ##OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE 'OCC. GROUP DESCRIPTION OF WORK:Include Square Feet of Affected Area(s). Nek...J (CG eacktAcki.t.../K-9A.mk-t .de.0-ccol cl.AL V-etV)-(e.cnoZ 3 40 n° EXISTING USE PROPOSED USE GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE 'AIR CONDITIONING FIRE SPRINKLERS YESO#___ NOEI YES ONO 0 YESD NOE „,,APPLICANT NAME ti.... i PROPERTY OWNER R f I k Primary Contact VI 1-i LA."..GI,til.PA.0.-r\bb a..evi .('t 3 -t-‘azor.:.15 ADDRESS ,,,.,1 ....ss i.....„„ sozo...vc *.2..„‘3......),...-ADDRESS (Clik7nC6Ortaf201,,C*• CITY Lie.kkoAce (P Heqe.> TE GA ZIP CITY 1 13G2 SATE 01/4 ZIP ett....( ( PHONE ._-7Tm s -/c6-1(/ONE FAX PH .-1(00 "522-''(lel 3 FAX EMAIL EMAIL I DESIGN PROFESSIONAL CONTRACTOR BUS. NAMECT73t 0C(tkeik-k- .\„.\4\&An,fi,),k;,'ADDRESS ADDRESS 2....7.6. eis- -0 scfm S47.51.tviLk 10'4 CITY STATE ZIP CITY STATE A ZIP VI'S Fd --Cr‘ciot1 PHONE FAX PHONE FAX%0 -2C15-5M EMAIL EMAIL STATE LIC. #STATE LIC1 ......°I S. ' CLASS CITY BUS. LIC.# .CI'20 (Sec.7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish.or repair any structure, prior to its issuance, also requires theapplicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of theBusiness and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to acivil penalty of not more than five hundred dollars ($500)). WORKERS'COMPENSATION Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations: lZhave and will maintain a certificate of consent to self•insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. LffI have and will maintain workep:' compinsation,as required by Sec'3700 of the Labor Code, for the performance of the work.fgr which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Co.p6'p%Vlitle-Ci Cirk"--...1.t6.C...:Policy No.taJcc 11810 1 -2-v7 Expiration Date ‘S../I./ 11 This section need not be completed if the permit is for one hundred dollars ($100) or less.0 Certificate of Exemption:I certify that in the performance of the work for which this permit is issued,I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Califomia.WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damagesa •rovided ..in S.'on 3706 of the Labor code, interest and attorney's fees... /I ,Ar .AGENTSCONTRACTOR SIGNATURE /".."'GENT DATElf 1 2-1(0,.-- OWNER -BUILDER DECLARATION I hereby affirm that/ am exempt from Contractor's License Law for the following reason: 1:3 I,as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). I,as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). ElI am exempt under Section Business and Professions Code for this reason: 1.I personally plan to provide the major labor and materials for construction of the proposed property improvement.laes Ohio 2.I (have / have not) signed an application for a building permit for the proposed work. 3.I have contracted with the following person (firm) to provide the proposed construction (include name address / phone I contractors' license number): 4.I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address/phone / contractors' license number): 5.I will provide some of the work, butI have contracted (hired) the following persons to provide the work indicated (include name I address / phone I type of work): RSPROPERTYOWNER SIGNATURE ['AGENT DATE CT IOW—'Po*P.IVO ICY I At_BUIL 01 NG PERMITS ONLY-"•wr;'vs:.„lima..'313k:-.C4401:;tii. Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?0 Yes 0 No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?0 Yes 0 No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?0 Yes 0 No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. miO.NSTRUCTI.ON LENDIFFiG A.ONCY I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name Lender's Address APPLICANT CERTIFICATION Icertify thatI have read the application and state that the aboveintonationis correct and that the information on the plans is accurate.Iagree to comply with all City ordinances and State lava relating to building consbeclion. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes.IALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY INANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or consttuction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void tithe building or work authorized by such permitis not commenced within 180 days from the date of such permit or if the building o rk authoriz su rmit is suspended or abandoned at any time after the work is commenced fora period of 180 days (Section 106.4.4 Uniform Building Code). RSAPPLICANT'S SIGNATURE DATE 71 te) C TOP" STOP:THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. Fax (760) 602-8560, Email building@carlsbadca.govor Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008. CO#:(Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX EMAIL OCCUPANT'S BUS. LIC. No. DELIVERY OPTIONS PICK UP:o CONTACT (Listed above)o OCCUPANT (Listed above) o CONTRACTOR (On P.1) o ASSOCIATED CB#MAIL TO:o CONTACT (Listed above)o OCCUPANT (Listed above) o CONTRACTOR (On Pg 1)o NO CHANGE IN USE /NO CONSTRUCTION MAIL /FAX TO OTHER:o CHANGE OF USE /NO CONSTRUCTION „teAPPLICANT'S SIGNATURE DATE Inspection List Permit#:CB163098 Type:PME DEZONIA: REPLACE FAU/ ADD AC W/ ELECTRIC Date Inspection Item Inspector Act Comments 09/20/2016 43 AirCond/Furnace Set RI 09/20/2016 43 AirCond/Furnace Set JW AP 09/20/2016 49 Final Mechanical RI 09/20/2016 49 Final Mechanical JW AP Wednesday, September 21, 2016 Page 1 of 1 1 CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)(Page 1 of 3 ) Project Name:ROB &KRISTI DEZONIA Date Prepared:2016-08-12 , 1 A. General Information I CF1R-ALT-02 is applicable to multiple space conditioning systems contained within a single dwelling unit. When multiple dwelling units must be documented, use one CF1R-ALT-02 document for each dwelling unit. - 01 Project Name ROB &KRISTI DEZONIA 02 Date Prepared 2016-08-12 03 Project Location 1723 CATALPA ROAD 04 Building Type Single family 05 CA City Carlsbad 06 Dwelling Unit Name ROB &KRISTI DEZONIA Dwelling Unit Conditioned07Zip Code 92011 08 1600Floor Area (ft2) Number of space conditioning 09 Climate Zone 7 10 (SC)systems in this dwelling 1 unit. B. Space Conditioning (SC) System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing a SC System SC System CFA served system a refrigerant Installing new SC Installing Installing Installing Identification or Location or Area by this SC ducted containing system more than 40 entirely new entirely new Name Served System (ft2)system?component?components?feet of ducts?duct system?SC system?Alteration Type System 1 Location 1 1600 Yes Yes Yes No No No Altered space conditioning system C.Extension of Existing Duct System, Greater Than 40 Feet (Section150.2(b)1Diib) This section does not apply to this project. Registration Number: 216-A0300625A-000000000-0000 Registration Date/Time:2016-08-12 08:25:36 HERS Provider:CaICERTS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-08-12 08:26:05 Schema Version: 0.5S5SDD i CERTIFICATE OF COMPLIANCE CF1R-ALT-02-E Alterations to Space Conditioning Systems (formerly CF-1R-ALT-HVAC)(Page 2 of 3 ) D.Altered Space Conditioning System (Sections 150.2(b)1E and F) 01 02 03 04 05 06 07 08 09 10 11 12 Heating Cooling System Heating Altered Heating Minimum Altered Cooling Minimum Required New or Identification System Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency Thermostat Replaced New Duct or Name Type Components Type Value System Type Components Type Value Type Duct Length R-Value All new All new This field or This field orCentral gas heating AFUE 80 Central splitSystem1 cooling SEER 16 Setback section is not section is notfurnaceACcomponentscomponentsapplicableapplicable Reauired Documentation: CF2R-MCH-01-E -Space Conditioning Systems Ducts and Fans -Duct insulation requirement for new plenums:R6. CF2R-MCH-20-H & CF3R-MCH-20-H —Duct Leakage testing required when heating or cooling components are Installed In ducted systems, or when more than 40ft of duct length is replaced. -Leakage rate compliance: 515%, or 510% leakage to outside, or seal all accessible leaks. CF2R-MCH-25-H &CF3R-MCH-25-H Refrigerant Charge Verification required when refrigerant containing components are Installed or altered (applicable in CZ 2, 8-15). CF2RCF3R-MCH-23 &CF3R-MCH-23 Air Flow i 300 CFM/ton required when MCH-25 Is required. Exceptions: -Duct systems registered with HERS provider as previously sealed are exempt from MCH-20 Duct Leakage Testing requirements. -Heating-only systems and Air Handler/Furnace changes do not require verification of Air Flow MCH-23, or Refrigerant Charge MECH-25. -Existing duct systems constructed, Insulated or sealed with asbestos are exempt from MCH-20 Duct Leakage Testing requirements. E.Entirely New or Complete Replacement Duct System, with or without Equipment Changeout (Sections 150.2(b)1Diia and 150.2(b)1E,F) This section does not apply to this project. F.Entirely New or Complete Replacement Space Conditioning System (Section 150.2(b)1C) This section does not apply to this project. Registration Number: 216-A0300625A-000000000-0000 Registration Date/Time:2016-08-12 08:25:36 HERS Provider:CaICERTS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.007 Report Generated: 2016-08-12 08:26:05 Schema Version: 0.555SDD 1 . ,. CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of 7 ) Project Name:Rob & Kristi Dezonia Enforcement Agency:City of Carlsbad Permit Number:16-3098 I, I Dwelling Address:1723 Catalpa Road [HOUSE]City:Carlsbad Zip Code:92011 i A. General Information 01 Dwelling Unit Name HOUSE 02 Climate Zone 7 1 Dwelling Unit Total Conditioned Floor Number of Space Conditioning03160004 1Area (ft2)Systems in this Dwelling Unit. 05 Certificate of Compliance Type Prescriptive alterations (CF1R-ALT )06 Method used to Calculate HVAC Loads NotApplicableEquipmentChangeout Calculated Dwelling Unit Sensible Calculated Dwelling Unit Heating Load07This field or section is not applicable 08 This field or section is not applicableCooling Load (Btuh)(Btuh) 09 Dwelling Unit Number of Bedrooms 4 MCH-Olb Space Conditioning Systems Ducts and Fans -Prescriptive Alterations B.Space Conditioning (SC)System Information 01 02 03 04 05 06 07 08 09 10 Is the SC Installing aSCSystemSCSystemCFAserved Installing new SC Installing more Installing InstallingsystemarefrigerantIdentification or Location or Area by this SC ducted containing system than 40 feet of entirely new entirely new SC Alteration Type Name Served System (ft2)components?ducts?duct system?system?system?component? .— Altered space SYSTEM 1 WHOLE HOUSE 1600 Yes Yes Yes No No No conditioning system Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008 k 1 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 2 of 7 ) E 1 t C.Space Conditioning (SC)System Alterations Compliance Information 01 02 03 04 05 06 07 08 09 10 11 12 13,' i Central FanIIIntegratedHeatingCoolingNew or (CFI) System Identification Heating Efficiency Efficiency Cooling or Name Heating Altered Heating Minimum System Type Component Type Altered Value System Type Components CoolingTypeValueType Minimum Required Replaced New Ventilation Cooling Efficiency Efficiency Thermostat Duct Duct System Length R-Value Status 1 ' This field Anew or- Central gas heating Central All new N/A nosectio Not a CFISYSTEM 1 AFUE 0.80 cooling SEER 16 Setback ductsfurnacecomponensplitAC n is systemcomponentsreplacedisnot applic able D.Installed Heating Equipment Information 01 02 03 04 05 06 07_— System Identification or Heating Efficiency Heating Unit Heating Unit Heating Unit serial Rated Heating Capacity, Name Heating Efficiency Type Value Manufacturer Model Number number Output (BTUH) SYSTEM 1 AFUE 80.0 GOODMAN GMH80603AXBB 1505022312 60000 Notes: Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 3 of 7 ) E.Installed Cooling Equipment information 01 02 03 04 05 06 07 08 1 Condenser or Package Unit Condenser or Condenser or Condenser or System Rated Cooling Condenser Rated System Identification Cooling Efficiency Cooling Efficiency Package Unit Package Unit Package Unit Capacity at Design Nominal Capacity or Name Type Value Manufacturer Model Number Serial Number Conditions (BTUH)(ton) SYSTEM 1 SEER 16.0 GOODMAN GSX160361FD 1606211092 36000 3.00 Notes: F.Extension of Existing Duct System, Greater Than 40 Feet This section does not apply to this project. G.Installed Duct System information This section does not apply to this project. H.Installed Air Filter Device Information This section does not apply to this project. I.Air Filter Device Requirements This section does not apply to this project. Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008 .• 1 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E I Space Conditioning Systems, Ducts, and Fans (Page 4 of 7 ) ; I J. HERS Verification RequirementsI0102 03 04 05 06 07 08 09 10 i - i MCH2O MCH21 MCH22 MCH23 MCH25 MCH28 1 Exemption from Minimum Exemption R-Value for AHU System SC System From Duct Duct Ducts In Ducts Located AHU Fan Airflow Identification or Location or Area Leakage Leakage Conditioned In Cond Space Efficacy Rate Refrigerant Return Duct Design 1 Name Served Requirements Test Space Verification (W/cfm)(cfm/ton)Charge Table 150.0-C or D This field or I No section is I SYSTEM 1 WHOLE HOUSE Yes No No No No No I exemptions not applicable Notes: Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of 7 ) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours.See Sections 150.0(i), 110.2(b). Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing.See sections03150.0(h)1 and 2). 04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature rise specification.See Section 150.0(h)4. 05 Standby Losses and Pilot Lights:Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment 06 Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet.See Section 150.0(h)3A. 09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing.See Section 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 10 .Insulation:In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements.See Section 150.0(m)1. Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of 7 ) K.Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 602.0, 603.0, 604.0, 605.0 and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or11enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 A thermostat shall be installed that meets the requirements of Section 110.2(b) and Section 110.2(c). 13 The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 First stage of heating shall be assigned to heat pump heating. 15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 7 ) Documentation Author's Declaration Statement 1.I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name:Documentation Author Signature: Rich Johnson iz3vJoh4q4o-tv Company:Signature Date: Sherlock Heating & Air Conditioning, Inc.2016-09-12 Address:CEA/HERS Certification Identification (if applicable): 2880 Scott Street #104 City/State/Zip:Phone: Vista CA 92081 760-295-5014 Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: 1.The information provided on this Certificate of Installation is true and correct. 2.I am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement (responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3.The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4.I reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5.I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections.I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name:Responsible Builder/Installer Signature: Rich Johnson ichjohn4o-vv Company Name: (Installing Subcontractor or General Contractor or Builder/Owner)Position With Company (Title): Sherlock Heating & Air Conditioning, Inc.Contractor/Installer Address:CSLB License: 2880 Scott Street #104 804838 City/State/Zip:Phone:Date Signed: Vista CA 92081 760-295-5014 2016-09-12 Digitally signed by CHEERSTM.This digital signature is provided in orderto secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information. Registration Number: 416-A0004326A-M0100001A-0000 Registration Date/Time: 2016-09-12 01:25:36 HERS Provider:CHEERS CA Building Energy Efficiency Standards -2013 Residential Compliance Report Version: 2013 Rev 1.008 Report Generated: 2016-09-12 13:25:40 Schema Version: 2013.1.008