Loading...
HomeMy WebLinkAbout1724 Geranium St; ; CBR2018-2821; Permit('city of Carlsbad Residential Permit Print Date: 12/18/2018 Permit No: CBR2018-2821 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 1724 Geranium St BLOG-Residential 2155500300 $10,850.40 Work Class: Lot#: Reference #: Construction Type: Bathrooms: Orig. Plan Check#: Patio Status: Applied: Issued: Permit Finaled: Inspector: Closed -Finaled 10/16/2018 10/16/2018 Plan Check#: Final Inspection: 12/18/2018 10:01:31AM Project Title: Description: BERTOZZI: 264 SF ATTACHED CITY STANDARD PATIO COVER BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $212.92 Owner: TRUST BERTOZZI FAMILY TRUST05-15-06 1724 Geranium St CARLSBAD, CA 92011 Total Payments To Date: $212.92 Co-Applicant: STONEBROOK LANDSCAPES Po Box 462413 Escondido, CA 92046-2413 760-445-4242 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020{a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition, You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 I I www.carlsbadca.gov $123.83 $86.68 $1.00 $1.41 (city of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 JobAddress l7Z-4 ~IYM 4Srr Suite: ____ APN: ZIS-SSD-03,-O0 CT /Project#: __________ Lot#: ____ Fire Sprinklers: yes / no Air Conditioning: yes / no BRIEF DESCRIPTION OF WORK: _____ C=r~\.y=,-....,.S~\--_c..~11=d,Pl~rJ~-~--ac,1,u, __ J __ u_1_,,__.¢'~_ ~ Addition/New: _____ Living SF,----,~ Deck SF, Zc, t{ Patio S , ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes@ New Fireplace? es/ No, if yes how many? __ D Remodel: _____ SF of affected area Is the area a conversion or change of use ? Yes/ No 0 Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ D Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ____________________________________ _ D Plumbing/Mechanical/Electrical Only: _________________________ _ D Other: ___________________________________ _ APPLICANT (PRIMARY) Name: #>re,11 ~ Address: 'Po Et,.,._ LlbZ,'-/1 !;;, City:e':=Co}.,IPl/>O State:_gA__Zip: q-t,01./0 PROPERTY OWNER Name: )\)...~. :As'-'t:, ~S -hPc!P-"''2-( Address:l"'\'21.\ GE:?JIN,1'-',,--<;.-r City:~"'~ State:~Zip: <.\Zo I\ Phone: ::7fe0-'27:7--Q(,a:;J-, Phone: ___________________ _ Email:~ Email: ___________________ _ ~~o~l::>b.Glci'a::. ~ '1'11rl1l-,Cc.l,I,,\. DESIGN PROFESSIONAL CONTRACTOR BUSINESS Name: _________________ Name: ?!?)~IL ~~=s, Address:_______________ Address: >'D "&:>..c, Ltlo.?4\:!, City: _______ State: __ Zip: ____ City: ~i-n::,i= State: C.,.. Zip: q 'l-0 Li Co Phone: Phone: 7l"DO • 2-17 -0 ~ 'l ::J Email: Email:S,,4'6-!g;:Ol..:.1~ c ~ @~L, Cil!'l'- Architect State License: State License: (p-:32, I~ Bus, License: a.oE.•'L~~ (Sec. 7031.S Bus·1ness and Profess·1ons Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500)). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: •\have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the labor Code, forthe performance of the work which this permit is issued. t/N-have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: lnsurancelCo~any Name:OHfD ?E4/2QY /IJ$U~l:--t C. 0, Policy No. ><~(,q)5'2, '-l,'i?:,57 * I Expiration Date: ~D~-Z.c,_~O.,lf-''--"''1----- • Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, :::::;::•:;~::TURE:~ ~GENT DATE: /0/(J!~ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License law for the following reason: DI, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). D I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. D Yes D No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person {firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. l will provide some of the work, but! have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: _________________ •AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ _ Lender's Address: _____________________ _ ONLY COMPLETE.THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25S05, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D Yes D No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes D No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR 15 MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CllY OF CARLSBAD AGAINST All LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINSTSAIDCllY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced with\ 80 a f the date of such permit or if the building or work authorized by such permit is suspended or abandoned at anytime after the work is commeoced foca days S ctioo 106.4.4 Uoiform Buildiog Code). / /7 , 2 I !,# APPLICANT SIGNATURE: '"-1-,.Jt.A'-,t-L...'-=--------------DATE: _Lt--'.....=v?::..wLb=--- 1635 Faraday Ave Carlsbad, CA 92008 B-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBR2018-2821) Permit Type: BLDG-Residential Application Date: 1011612018 Owner: Work Class: Patio Issue Date: 1011612018 Subdivision: Status: Closed -Finaled Expiration Date: 04129/2019 Address: IVR Number: 14639 Scheduled Date Actual Start Date Inspection Type Inspection No. Inspection Status Primary Inspector 10/31/2018 10/31/2018 12/18/2018 12/18/2018 December 18, 2018 BLDG-11 Foundatlon/Ftg/Pler s (Rebar) 074654-2018 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 079267-2018 Checklist Item BLDG-Building Deficiency BLOG-Plumbing Final BLOG-Mechanical Final BLDG-Structural Final BLDG-Electrical Final Passed Michael Collins COMMENTS Column footings Passed Paul Burnette COMMENTS TRUST BERTOZZI FAMILY TRUST 05-15-06 CARLSBAD TCT#79-04 1724 Geranium St Carlsbad, CA 92011-5117 Re inspection Complete Complete Passed Yes Complete Passed No No No No No Page 1 of 1 ( Cicyof Carlsbad RESIDENTIAL PATIO B-8 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www .carlsbadca.gov Patio covers are one story, roofed structures not more than 12 feet above grade and used for outdoor recreational purposes. A building permit is required for all attached residential patio covers. Detached residential patio covers that are 120 square feet of roof area or less, do not require a permit. All patio covers, of any size, need to comply with the Zoning Ordinance, including building setbacks, structure separation requirements and lot coverage. This hand out describes what plans are necessary to secure a patio cover permit. To assist you, there is a sample of a plot plan, span tables for joists, and beams, and a footing schedule for foundation requirements. There are also connection details to use for typical connections. You may use this handout in lieu of a separate design when the patio cover is attached to the house on one complete side. If you design the patio cover yourself, or your patio cover is either free-standing or outside the span table limits in this handout, please provide a foundation plan, framing details, and other details and elevations to show the extent of the proposed work. A lateral analysis may be required for free-standing patio covers. If you use the attached tables and plans, please submit the following: 1. Two Identical Site Plans showing: a) Property lines with dimensions. b) Proposed roof area of the patio cover. c) Distances from posts to property lines. d) All existing structures on the property. e) Indicate the dimensions of the patio cover and the total roofed area. f) Any easements on the property. g) Show slopes or topography of the lot. h) Indicate percentage of lot coverage. 2. A Building Permit Application with the following: a) Name of the property owner. b) Home Phone Number c) Site address, assessor's parcel number, lot number, subdivision name or number. d) Contractor's name, State License Number and City Business License Number; or an Owner-Builder Declaration Form (Available at the Building Division Counter). e) Copy of Worker's Compensation Certificate I) Signature of Applicant If you are applying for a building permit in the Coastal Zone, you may need a Coastal Development Permit or an exemption. Contact the Planning Division for details. A Coastal Zone map is part of this handout. If you are applying for a building permit in a subdivision with a homeowner's association, you should secure architectural review prior to proceeding with the project. The City does not enforce or specifically review provisions of homeowners' association CC&R's. HOA requirements may be different than City requirements. If your home is part of a Planned Unit Development or a condominium, please see text of this handout. B-2 Page 1 of 8 Rev. 05/12 TYPICAL R-1 PLOT PLAN DIIMWAY PR0PSITY ._.. Ctl I I : . ------~-·----·······"- I I "7:=:i ·_ 71 20% of LOT ( REAR YARD WDTH TOA MAX.~,20' PRCroSEO .-ooTION ~ 10% It- EXISTNO RESIDENCE ~ I ~ DRAW.GE 2% MIN. --------1 - 20' I , \ 10 LO UP It.-IC. II MA [/ %OF TWTH TOA X.OF 10' J/ --- / _,,LO Tv,()TH WEASURED 20' OM 20' BACK OF FR F RONT PROPERTY LINE ~ OPERTY~E L--__ ._ __ ~ -~~c!?.. ___ ._ ' '" - STREET Setbacks shown are for R-1 parce ls. Front Yard = 20' from the front property line. Interior side yard = 10% of lot w idth up to a maximum of 10'. (Min. 5'). Street side yard = 10'. Rear yard -20% of lot width up to a maximum of 20' (Min. 10'). Maximum lot coverage = 40%. Include solid roof patios, attached or detached in the calculation. Contact t he Planning Division (760-602-4610) for information on corner lots, lots with unusual configurations, lots within Planned Communities, accessory structures and building heights. Solid Roof Patios -If roofing to be applied is TILE use the next, larger span/spacing on the following tables. Minimum Square Footing Sizes (inches)1•2 Post Rafter Span (in feet) Soacln« 6 8 ' 1.0 12 1A 1.6 18 20 4 12 12 12 12 12 12 12 12 6 12 12 12 12 12 12 12 14 8 12 12 12 12 12 14 14 14 1.0 12 12 12 14 14 14 J.G... 16 12 12 12 14 14 16 16 ( 18) 18 1A 12 12 14 16 16 18 18 20 1.6 12 14 14 16 18 18 20 20 18 12 14 16 18 18 20 20 22 20 14 14 16 18 20 20 22 24 1. Assumes 1,000 psi soil bearing capacity 2. The minimum depth for all footings is 12 inches into natural grade B-2 Page 2 of 8 Rev. 5/12 Minimum Rafter Sizes Rafter Rafter Spacing -Center to Center (in inches) 12" (5/16" ply-18" (1/2" ply-24" (1/2" ply-32" (5/8" ply- Span wood sheathinq) wood sheathinq) wood sheathinq) wood sheathina\ 8 2x4 2x4 2x4 2x4 7 2x4 2x4 2x4 2x4 8 2x4 2x4 2x6 (2x6"\ 9 2x4 2x6 2x6 2x6 1.0 2x6 2x6 2x6 2x6 11 2x6 2x6 2x6 2x8 12 2x6 2x6 2x6 2x8 13 2x6 2x6 2x8 2x8 14 2x6 2x6 2x8 2x8 1.5 2x6 2x8 2x8 2 X 10 18 2x8 2x8 2x8 2 X 10 17 2x8 2x8 2 X 10 2 X 10 18 2x8 2x8 2 X 10 2 X 10 19 2x8 2 X 10 2 X 10 2 X 12 20 2x8 2 X 10 2 X 10 2 X 12 Minimum Beam Sizes Post Rafter Span (in feet) Spacing 4 8 8 1.0 12 14 18 18 20 4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4 x 4 4x4 8 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x4 4x6 8 4x4 4x4 4x6 4x6 4x6 4x6 4x6 4x6 4x6 10 4x4 4x6 4 x6 4x6 4x6 4x6 4x8 4x8 4 x8 12 4x6 4x6 4x8 4x8 4x8 4x8 4x8 4x8 4 X 10 6x8 6x8 6x8 6x8 14 4x6 4x8 4x8 4x8 4x8 4 X 10 4 X 10 4 X 10 4 X 10 6x8 6x8 6 X 10 6 X 10 6 X 10 18 4x8 4x8 4x8 4 X 10 4 X 10 4 X 10 4 X 12 4 X 12 4 x 14 6x8 6x8 6x8 6 X 10 6 X 10 6 X 10 1--S X 10) 18 4x8 4x8 4 X 10 4 X 10 4 X 10 4 X 12 4 X 12 4 X 14 4 X 14 6x8 6x8 6x8 6 X 10 6 X 10 6 X 10 6 X 12 6 X 12 20 4x8 4 X 10 4 X 10 4 X 12 4 X 12 4 X 14 4 X 14 6x8 6x8 6 X 10 6 X 10 6 X 10 6 X 12 6 X 12 6 X 12 6 X 14 B-2 Page 3 of 8 Rev. 05/12 Figure 2 / Typical Patio 12· Min. Post spacing Main beam spacing Continuous solid blocking at beam between rafters Figure 3 / Post-to-Girder Connection Case 1 / Connection, Interior Condition r Approved post cap 7 gauge steel 'L' straps, 1/2' wide each side with (4) 518" diameter bolts, a• along beam, 12' along post. Provide 4X4 knee brace for top-to-bottom brace on the ln~or side of all post-to-beam connactions when post height exceeds 4'-0". Two 112• diameter lag bolts top & bottom (typical) see figure 5 for footing details Case 2 / Interior Condition APProved post cap or 7 gauge steel 'L' straps, 112" wide each side with (4) 5/8" diameter bolts, a• along beam, 12• along post. 18" Min. I B-2 Page 4 of 8 Rev. 05/12