HomeMy WebLinkAbout1730 Yada Pl; ; CBRA2018-0056; PermitPermit
Print Date: 10/30/2019
Job Address:
{city of
Carlsbad
Permit No: CBRA2018-0056
Permit Type:
Parcel No:
1730 Vada Pl
BLDG-Associated Permit Resi
1562206000
Work Class:
Lot#:
Single Family Detached
7
Status:
Applied:
Closed -Finaled
03/13/2018
04/17/2019 Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
$571,865.52
1
4.00
VADA FARM
Reference #: DEV02058
Construction Type: VB
Bathrooms: 3.50
Orig. Plan Check#: PC2017-0048
Plan Check#:
Issued:
Permit
Fina led:
Inspector: MColl
Final
Inspection: 10/30/2019 10:00:00A
Description: VADA FARM: PHASE 1 // LOT 7 // PLAN 3BR // 3,527 SF// 175 SF PATIO// 689 SF GARAGE// 128 SF PORCH
Applicant:
MARY NETTLES
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-2829
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
Owner:
TRUSTY ADA FAMILY TRUST 03-12-90
1835 Buena Vista Way
CARLSBAD,CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PARK IN-LIEU FEES SF DETACHED & DUPLEX: NW
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFO
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 3/4" Displacement
SEWER CONNECTION FEE {General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
TRAFFIC IMPACT Residential Single Fam. Outside CFO
WATER METER FEE 1" Displacement (P)
WATER SERVICE CONNECTION FEE 3/4" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 3/4" Displacement
Total Fees: $48,523.56 Total Payments To Date: $48,523.56
Contractor:
CALIFORNIA WEST CONSTRUCTION INC
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-6768
Balance Due: $0.00
$2,253.00
$1,450.93
$96.00
$170.00
$110.00
$7,649.00
$224.00
$20,015.29
$23.00
$5,267.00
$960.00
$74.34
$246.00
$56.00
$3,390.00
$282.00
$6,111.00
$146.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0056)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 04/27/2020 Address:
IVR Number: 10092
Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector
October 30, 2019
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Electrical Final
BLDG-Fire Final 107962-2019
Checklist Item
FIRE-Building Final
COMMENTS
No superintendent on site. Job office
locked.
See card for pick up
AFCI, GFCI, T-24 ok. CO and Smoke
detectors ok.
Scheduled
COMMENTS
Felix Salcedo
TRUST YADA FAMILY TRUST
03-12-90
1730 Yada Pl
Carlsbad, CA 92008
Re inspection Complete
Passed
No
Yes
No
Yes
Yes
Yes
Incomplete
Passed
No
Page 4 of 4
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0056)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 04/27/2020 Address:
IVR Number: 10092
Scheduled Actual Date Start Date Inspection Type Inspection No, Inspection Status Primary Inspector
Checklist Item
BLDG-Building Deficiency
10107/2019 10/0712019 BLDG-Electric Meter 106638-2019
Release
Checklist Item
BLDG-Building Deficiency
10/17/2019 10/17/2019 BLDG-Gas Meter
Release
107857-2019
1012512019 10/2512019 BLDG-Final
Inspection
10/28/2019 10128/2019 BLDG-Final
Inspection
Checklist Item
BLDG-Building Deficiency
108728-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
108914-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
10/29/2019 10/29/2019 BLDG-16 lnsulatlon 109096-2019
Checklist Item
BLDG-Final
Inspection
10/30/2019 10/30/2019 BLDG-Final
Inspection
October 30, 2019
BLDG-Building Deficiency
109097-2019
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
109455-2019
COMMENTS
No superintendent on site. Job office
locked.
Passed Michael Collins
COMMENTS
EMR emailed to SDGE
Passed Peter Dreibelbis
COMMENTS
Failed Michael Collins
COMMENTS
See card for pick up
No superintendent on site. Job office
locked.
Partial Pass Michael Collins
COMMENTS
See card for pick up
No superintendent on site. Job office
locked.
Cancelled Michael Collins
COMMENTS
Partial Pass Michael Collins
COMMENTS
No superintendent on site. Job office
locked.
See card for pick up
Passed Michael Collins
TRUST YADA FAMILY TRUST
03-12-90
1730 Yada Pl
Carlsbad, CA 92008
Reinspection
Passed
No
Passed
Yes
Passed
No
Reinspection
Passed
No
No
Reinspection
Passed
No
No
Reinspection
Passed
No
Reinspection
Passed
No
No
Complete
Complete
Complete
Complete
Incomplete
Complete
Incomplete
Complete
Page 3 014
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0056)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: TRUST YADA FAMILY TRUST
03-12-90
Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 04/27/2020 Address: 1730 Yada Pl
Carlsbad, CA 92008
IVR Number: 10092
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
07/31/2019 07/31/2019 BLDG-16 lnsulatlon 099271-2019 Failed Michael Collins Relnspection Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
08/01/2019 08/01/2019 BLDG-16 Insulation 099373-2019 Passed Michael Collins Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-Building Deficiency Yes
08/07/2019 08/07/2019 BLDG-17 Interior 099977-2019 Failed Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-18 Exterior 099976-2019 Failed Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
08/08/2019 08/08/2019 BLDG-17 Interior 100214-2019 Failed Michael Collins Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready, need scrap out No
08/09/2019 08/09/2019 BLDG-17 Interior 100350-2019 Passed Peter Dreibelbis Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready, need scrap out Yes
BLDG-18 Exterior 100349-2019 Passed Peter Dreibelbis Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/03/2019 10/03/2019 BLDG-Final 106411-2019 Failed Michael Collins Reinspection Complete
Inspection
October 30, 2019 Page 2 of4
--------.
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0056)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: TRUST YADA FAMILY TRUST
03-12-90
Work Class: Single Family Detached Issue Date: 04/17/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 04/27/2020 Address: 1730 Yada Pl
Carlsbad, CA 92008
IVR Number: 10092
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete Date Start Date
04/18/2019 04/18/2019 BLDG-SW-Pre-Con 089252-2019 Passed Paul Burnette Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
05/06/2019 05/06/2019 BLDG-21 090943-2019 Passed Tim Frazee Complete
Underground/Underf
loor Plumbing
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
05/10/2019 05/10/2019 BLDG-11 091519-2019 Passed Tim Frazee Complete
Foundation/Fig/Pier
s (Rebar)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
06/10/2019 06/10/2019 BLDG-14 094214-2019 Partial Pass Michael Collins Reinspection Incomplete
Frame/Steel/Bolling/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 2nd floor, floor sheathing Yes
07/01/2019 07/01/2019 BLDG-15 096159-2019 Failed Michael Collins Reinspection Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Dbl. ck. truss packages No
07/03/2019 07/03/2019 BLDG-15 096548-2019 Passed Michael Collins Complete
Roof/ReRoof (Patio)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Dbl. ck. truss packages No
BLDG-Building Deficiency Sheathing nailing ok. Provide hanger call Yes
out update
07/15/2019 07/15/2019 BLDG-13 Shear 097 453-2019 Passed Michael Collins Complete
Panels/HD (ok to
wrap)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
07/26/2019 07/26/2019 BLDG-84 Rough 098831-2019 Passed Paul Burnette Complete
Combo(14,24,34,44)
October 30, 2019 Page 1 of4
~~--~ CITY O F
CARLSBAD
Building Division INSPECTION 'RECORD
P-H NSPECTION RECORD CARD WITH APPROVED
lcT\
CBRA2018-0056
1730YADA PL
VADA FARM: PHASE 1 // LOT 7 // PLAN 3BR // 3.527 SF//
175 SF PATIO II 689 SF GARAGE// 128 SF PORCH
)NS MUST BE KEPT ON THE JOB
-~LL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION DEV02058 1562206000
0 FOR BUILDING INSPECTION CA.LL: 760-602-2725 PC2017-0048 4/1812018
OR GO TO: www.Carlsbadca.gov/Building AND CLICK-ON ,.
"Request Inspection" • . CBRA2018-0056
DATE: -\2-\
If "YES" is checked below that Division's approval is required rior to re uesti!l~ a Final Building Inspection. If you have any questions
please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to
760-602-8560, email to bid ins ections@carlsbadca. ov or bring In a COPY of this card to: 1635 Faraday Ave., Carlsbad.
IF MARKED "YES#, IT IS REQUIRED PRIOR TO ANY CONSTRUCTION
STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours
IF MARKED "YES#, APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING
Fire Prevention 760-602-4660 ~ Allow 48 hours
Planning/Landscape 760-944-8463 Allow 48 hours
760-438-3891 Call before 2 pm
#12 REINFORCED STEEL #34 ROUGH ELECTRIC/ EV CHARGER
#66 MASONRY PRE GROUT #33 LEC SERVICE #32OTEMPORARY
GROUT D WALL DRAINS #35 PHOTO VOLTAIC
TILT PANELS #38 SIGNS
#11 POUR STRIPS BLDG-FINAL ---------+------+-----#11 COLUMN FOOTINGS CODE# MECHANICAL
#14 #41 UNDERGROUND DUCTS & PIPING
#15 ROOF SHEATHING #44 0 DUCT & PLENUM 0 REF. PIPING
#13 EXT. SHEAR PANELS #43 HEAT-AIR COND. SYSTEMS
#16 INSULATION
#18 EXTERIOR LATH
#17
#82 DRYWALL,EXTLATH, GAS TES (17,18,23)
#83 ROOF SH EATING, EXT SHEAR (13,15)
D SEWER & BL/CO D PL/CO #84 FRAME ROUGH COMBO (14,24,34,44)
UNDERGROUND ASTE [XWTR
#24 TOP OUT D WASTE D WTR
#27 TUB & SHOWER PAN
#23 D GAS TEST D GAS PIPING A/S UNDERGROUND VISUAL
#25 WATER HEATER A/S UNDERGROUND HYDRO
#28 SOLAR WATER A/S UNDERGROUND FLUSH
BLDG-FINAL A/S OVERHEAD VISUAL
CODE# POOLS Date Ins ector A/S OVERHEAD HYDROSTATIC
#51 POOL EXCAV / STEEL A/S FINAL
#52 PLUMBING F / A ROUGH-IN
#53 ELEC /CONDUIT/WIRING F/A FINAL
EQUIPOTENTIAL BOND FIXED EXTINGUISHING SYSTEM ROUGH-IN
PREPLASTER / FENCE/ ALARMS FIXED EXTING SYSTEM HYDROSTATIC TEST
#57 GUNITE FIXED EXTINGUISHING SYSTEM FINAL
BLDG-FINAL MEDICAL GAS PRESSURE TEST
MEDICAL GAS FINAL
REV 9/17
Date
Date
Date
COPYOFCARD
REQUIRED
Inspector
Ins ector
SEE BACK FOR SPECIAL NOTES
GEOSOILS, INC. W.O.: 7377-C-SC
Geotechnlcal-Coastal-Geologic -Ernironmental DATE: _____ 04_/-22/_1_9 ___ _
NAME: TODD ------------HOURS: 2.5 ------------
FOOTING TRENCH OBSERVATION SUMMARY
CLIENT NAME: CAL-WEST PROJECT NAME: VADA -------------
LOCATION/TRACT: VADA PL, CARLSBAD, CALIF
UNIT/PHASE/LOTS: LOTS 1,2,7,8,AND 12 ---------------------':..:..-'-'--------------------
REFERENCED GEOTECHNICAL REPORT: 6927-A-SC DATED AUGUST 3, 2015
OBSERVATION SUMMARY
TG INITIALS -------04/22/19 DATE -------
TG INITIALS -------04/22119 DATE -------
TG INITIALS -------04/22/19 DATE -------
TG INITIALS -------
04/22/19 DATE -------
A representative of GeoSoils, Inc. observed on site soil and footing conditions. son conditions in the trench
are generally free of loose soil and debris, non-yielding and unWorm, and plumb; and are in general
conformance with those indicated in the geotechnical report.
A representative of GeoSolls, Inc. obseived and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bea~ng strata, and are in general conformance with
recommendations of the geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope fece (if applicable). The setback was
in general accordance with the recommendations of the geotechnical report.
CONSULT THE PROJECT STRUCTURAL ENGINEER ABOUT GRAVEL FROM UTILITY LINE
ADJACENT NE CORNER OF LOT 12.
NOTES TO SUPERINTENDENT/FOREMAN
1. Footing excavations should be cleaned of loose debris and thoroughl_y moistened just prior to placing concrete.
2. Based on expansion potential of underlying soils, presoaklng of soil below slabs may be recommended. Consult the
geotechnical report for presoaking recommendations. We note that clayey soils may take an extended period time for
such, and the contractor should schedule accordingly.
3. In the event of a site change subsequent to our footing observation and prior to concrete placement (i.e. heavy rain, etc.),
we should be contacted to perform addltional site observations and/or testing-.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's design, if
different from the geotechnical report.
NOTES TO BUILDING INSPECTOR
Soll compaction test results, as well as depth of fill, relative compaction. bearing values, corrosivlty, and soil expansion index test results are
contained in the As~Graded Geotechnical or Final Compaction Report provided at the completion of grading.
DIGITAL DELIVERY: JIM HALL
Representative of GeoSoils, Inc.
b~A,lnc.
land planning, civil engineering, surveying
March 10, 2019
w.o. 944-1289-600
Mr. Tim Frazee
CITY OF CARLSBAD,
Building Inspection Division
1635 Faraday Avenue
Carlsbad, CA 92008
ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
RE: BUILDING FORM VERIFICATION FOR LOTS 1, 2, 7 AND 8 OF
THE YADA FAMILY FARM SUBDIVISION, CT 15-11
Dear Mr. Frazee:
This Jetter is to attest that BHA, Inc. has staked the locations for the house construction on the
above-mentioned lots. We have checked the locations of the building forms of the proposed
houses and found the horizontal and vertical locations to conform to the grading plans
prepared by our office.
If you have any questions regarding this matter, please contact our office.
Sincerely,
bl-iA, Inc.
-'fL_-~
Ronald L. Holloway
Senior Vice President
RCE29271
cc: Jim Hall-California West Communities
K:\Clvil 3D\1289\PROD\Survey\Pad-Forrn Ccris\[orms\CT 15-1 I_Lots 1-2-7-8 bldg-form•verification.wpd
5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780
I
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying
INSPECTION REPORT PAGE OF
GTE JOB NO. IC I'-/ l · r 4
PROJECT NAME '( ,~-· --tgJ:w I
ADDRESS f ... ~ I l r I r
(' l'
ARCHITECT
, L. INSPECTION
L □ CONCRETE
□ REINF. STEEL
□ MASONRY
REPORT NO.
MATERIAL IDENTIFICATION
CONC. MIX NO. & lb/in2
GROUT MIX NO. & lb/in2
MORT AR TYPE & lb/in2
ENGINEER □ P.T. CONCRETE REINF. STEEL GR./SIZE -, '-/;(/ ---~~-
CONTRACTOR ( r. I L □ FIELD WELDING STRUCTURAL STEEL
OTHER -t \ I '1 □ SHOP WELDING HIGH-STRENGTH BOLT ------
INSPECTION DATE .-L0 Ii □ BATCH PLANT
I I
PLAN FILE/OTHER □ EXP.ANCHOR
MASONRY BLOCK
OTHER
BLDG. PERMIT/OTHER 121 OTHER l I
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT 0 FIREPROOFING O MASONRY BLOCK ·
0 REINFORCING STEEL □ STRUCTURAL STEEL 0 BOLTS O OTHER
l
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER _PROJECT ISSUES.
< • -,, -ti , r -l e r, .\,JC.1 r . r.
,-IJ ., (• (-c.. ,,., ... ' L . I
,-r -I \ (' I -. I ..-,;
.j Ji.' I /.(,4ar'
( -I ti -' 17~ ?' 1 ,-( ( I u, r
l , -l ' -,, ,, f' ,. /7 (
L . -f ,, r (...
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications.
PRINTED NAME --,; \./ C. , r. r r::.. , , , c_
CERTIFICATION NO. • 1_ .¥ r7., --==------''-'--------SIGNATURE --'--_;_--=---c==----=='---
.JI
1441 Montiel Road, Suite 115 I Escondido, CA 92026 Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
bl-tA, Inc.
land planning, civil engineering, surveying
March 10, 2019
w.o. 944-1289-600
Mr. Tim Frazee
CITY OF CARLSBAD,
Building Inspection Division
1635 Faraday Avenue
Carlsbad, CA 92008
ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
RE: BUILDING FORM VERIFICATION FOR LOTS 1, 2, 7 AND 8 OF
THE YADA FAMILY FARM SUBDMSION, CT 15-11
Dear Mr. Frazee:
This letter is to attest that BHA, Inc. has staked the locations for the house construction on the
above-mentioned lots. We have checked the locations of the building forms of the proposed
houses and found the horizontal and vertical locations to conform to the grading plans
prepared by our office.
If you have any questions regarding this matter, please contact our office.
Sincerely,
bl-tA, Inc.
14---~
Ronald L. Holloway
Senior Vice President
RCE29271
cc: Jim Hall-California West Communities
K:\Civil 3D\1289\PROD\Survey\Pad-Form Certs\forms\CT 15-1 l_Lots 1-2-7-8 bldg-form-verification.wpd
5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 ° (760) 931-8700 ° FAX (760) 931-7780
<
(city of
Carlsbad
CERTIFICATION OF
SCHOOL FEES PAID
B-34
Development Services
Building Department
1635 Faraday Avenue
760-602-2719
www.carlsbadca.gov
This form must be completed by the City, the applicant, and the appropriate school districts and returned to the City
prior to issuing a building permit. The City will not issue any building permit without a completed school fee form.
Project Name ___,_Y,:,A,,,Dce:A!...F'-'A=.,R"'M,__ ____________________ _
Building Permit
Plan Check Number PC2017-0048 II CBRA2018-0056 & CBRA2018-0077 -LOT 7
Project Address: 1730 & 1732 YADA PLACE
A.P.N _1 ... s.,.6:::.-2..,2..,0::s-6,,,0c:,-O,.,,O,_ ___________________ _
Project Applicant CARLSBAD BUENA VISTA 12, LP
(Owner Name)
Project Description: _1;...;S.,_F-=D'-+--'1-'A-"D=-U=------------------------
Building Type
Residential: 2 NEW DWELLING UNIT(S)
3,527 Square Feet of Living Area in New Dwelling/s
Second Dwelling Unit: 358 Square Feet of Living Area in SOU
Residential Additions: Net Square Feet New Area
Commercial/Industrial: Net Square Feet New Area
City Certification of
Applicant Information, 51-iay Evew Date November 30, 2018
SCHOOL DISTRICTS WITHIN THE CITY OF CARLSBAD
[81 Carlsbad Unified School District
6225 El Camino Real
D Vista Unified School District D San Marcos Unified School District
Carlsbad CA 92009 (760-331-5000)
LJ Encinitas Union School District-
By appointment only
101 South Rancho Santa Fe Rd
Encinitas, CA 92024
1760-944-4300 x1166l
1234 Arcadia Drive 2 5 5 P i c o A v e S t e . 1 O O
Vista CA 92083 (760-726-2170) xt San Marcos, CA 92069 (760-290-2649)
2222 Contact: Katherine Marcelja (By Appl. Only)
LJ San Dieguito Union High School District-By Appointment Only
684 Requeza Dr.
Encinitas, CA 92024
(760-753-6491 X 5514)
Certification of Applicant/Owners. The person executing this declaration ("Owner") certifies under penalty of pe~ury
that (1) the information provided above is correct and true to the best of the Owner's knowledge, and that the Owner
will file an amended certification of payment and pay the additional fee if Owner requests an increase in the number
of dwelling units or square footage after the building permit is issued or if the initial determination of units or square
footage is found to be incorrect, and that (2) the Owner is the owner/developer of the above described project(s), or
that the person executing this declaration is authorized to sign on behalf of the Owner.
Signature: _i:/---l.--'-0-l---'.'---Q};-=tc..=2-"'-,~V"-----Date:
B-34 Page 1 of 2 Rev. 03/09
SCHOOL DISTRICT SCHOOL FEE CERTIFICATION
(To be completed by the school district( s))
***************************************************************************************************
THIS FORM INDICATES THAT THE SCHOOL DISTRICT REQUIREMENTS FOR THE
PROJECT HAVE BEEN OR WILL BE SATISFIED.
SCHOOL DISTRICT:
The undersigned, being duly authorized by the applicable School District, certifies that
the developer, builder, or owner has satisfied the obligation for school facilities. This is
to certify that the applicant listed on page 1 has paid all amounts or completed other
applicable school mitigation determined by the School District. The City may issue
building permits for this project.
SIGNATURE OF AUTHORIZED SCHOOL
DISTRICT OFFICIAL
TITLE
NAME OF SCHOOL DISTRICT
DATE
PHONE NUMBER
J;) <1 , B, . 10 = •::,c-, C , kw 4 J..O
le, G'-->-.. ""'-~.\ ""''°" ,"2:)
"S, '-P'4'' ,r -, Y\\,+ :v\ck/xd
CARLSBAD UNIFIED SCHOOL DISTRICT
6225 EL CAMINO REAL
CARLSBAD, CA 92009
11-1 <;--:...1 ~
'::1 lo(\ 3 3 I -5;:::0C)U
B-34 Page 2 of 2 Rev. 03/09