HomeMy WebLinkAbout1731 CATALPA RD; ; CB973504; PermitCity of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
05-15-2007 Building Permit Permit No:CB973504
Building Inspection Request Line (760) 602-2725
Job Address 1731 CATALPA RD CHAD
Permit Type RAD Sub Type ^- • —-^
Parcel No 2155120400 Lot # StatusC. EXPIRED^
Valuation $0 00 Const Type VN Applied 11/17/1997
OccGroup Reference # Entered By RMA
Appr/Issued
Project Title 300 SF ADDITION-1 STORY-FAMILY Inspect Area
ROOM
Applicant Owner
CLARK, RUSSEL CLARK G RUSSELL
1731 CATALPA RD
CARLSBAD CA 92011
760 431-2767
Total Fees $181 00 Payments To Date $181 00 Balance Due
$0 00
Description Fee
Other 181 00
FINAL APPROVAL
Inspector Date Clearance _.
NOTICE Please take NOTICE that approval of your prefect includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer t onnection fees and capactiy
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY lo any
Jess/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitationsjias previously otherwise expired
PERMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
2075 Las Palmas Dr, Carlsbad CA 92009
(760)438-1161
FOR OFFICE USE ONLY
PLAN CHECK NO
EST VAL cLfi *
Plan Ck Deposit
Validated By
Date UlAlLSL ^
T-J
Address (include Bldg/Suite #}
-1.S- "ZAO
Business Name (at this address)
Legal Description Lot No Subdivision Name/Number Unit No Phase No Total # of units
Assessor s Parcel ft Existing Use
0001 01—02
C-PRfcdf Bathroomsiei]Description of Work SQ FT #of Stories # of Bedrooms
n<*?> ;>H.->r* i TTS.S,
Name
jAgPUCANT, , !SG3 ^Contractor,
Name Address City
PROPERTY OWNER™
Telephone #
Name Address City State/Zip "telephtfne ft
J5l ^CONTRACTOR-COMPANY, NAME !" "( , 7J' .". .' "/ '„ ., . ' J! <! ' L , ' "",< ""* - 'i! " i ,1 ' , '
(Sec 7031 5 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contiactor's License Law
(Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt thsrefrom, and the basis for the alleged
exemption Any violation of Section 7031 5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500])
Name
State License #
Address
License Class
City State/Zip
City Business License ft
Telephone ft
Designer Name
State License #
Address City State/Zip Telephone
!6. , WORKERS' COMPENSATION!"j1,, 'L T7 . , ". '- T „' t , ,", \'Tj\'' ~ „„'> "l',.'.l I".1."*" ' " r": i .-
Workers' Compensation Declaration I hereby affirm under penalty of perjury one of the following declarations
n I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit is issued
Q I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is
issued My worker's compensation insurance carrier and policy number are
Insurance Company Policy No Expiration Date
(THIS SECTION NEED NOT BE COMPLETED IF THE PERMIT IS FOR ONE HUNDRED DOLLARS [51001 OR LESS)
0 CERTIFICATE OF EXEMPTION I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California
WARNING Failure to secure~workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred
thousand dollars ($1,00,000), in addition to.thft'pist of compensation, damages as provided for in Section 3706 of the Labor <jode-interest and attorney's fees
SIGNATURE V ^-^^L^U^^-^--^; DATE (
[7 " """ ' "*'"" " "
I hereby affirm that I am exempt from the Contractor's License Law for the following reason
[3 I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale
(Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does
such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is
sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale)
d I, as owner of the property, am exclusively contracting with licensed contractors to construct the proiect (Sec 7044 Business and Professions Code The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's License Law) i-
d I am exempt under Section Business and Professions Code for this reason
1 I personally plan to provide the major labor and materials for construction of the proposed property improvement H YES QNO
2 I (have / have not) signed an application for a building permit for the proposed work
3 I have contracted with the following person (firm) to provide the proposed construction (include name / address / phone number / contractors license number)
4 I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone
number / contractors license number)
5 I will provide some of the work, butj-have~contracted (hired) the/following persons to provide the work indicated (include name / address / phone number / type
of work) /"; 1 . S //// j_
PROPERTY OWNER SIGNATURE DATE
R^OW-ffK/W " > '. .
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration foim or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley- Tanner Hazardous Substance Account Act? Q YES Q NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality maneigement district? Q YES C] NO
Is the facility to be constructed within 1 ,000 feet of the outer boundary of a school site7 Q YE§ D N0
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT
I hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097{i) Civil Code)
LENDER'S NAME _ LENDER'S ADDRESS __
'a\' ", APPLICANT^ cERTiFtCATidNT^r; r, T J" r ITi .. 'VJ ___'.. ,.~ „ IJ"J1 ™ v;, "7\'i "" ^j.S'r ',su *w r»1l j",1 "~ *1'-
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all
City ordinances and State laws relating to building construction I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned
property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES,
JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT
OSHA An OSHA permit is required for excavations over 5'0" deep and demolition or construction of structures over 3 stories in height
EXPIRATION Every permit issued by the Building OffTctal under the provisions of this Code shall expire by limitation and become null and void if the building or
work authorized by such permit is not commenced withiry365 days frp^Mne date of such permit or if the building or work authorized by such permit is suspended
or abandoned at any time after the .work is commencerLror a penpd/6/^ 8Udavs (Sfection 106 4 4 Uniform Building Code)
APPLICANT S SIGNATURE DATE
WHITE File YELLOW Applicant PINK Finance
City of Carlsbad
——— —*T ^W^^^VWM^^^^MlHm^^^^^^MMII^^^^MBuilding Department
DATE: 09/30/98
TO: CLARK, RUSSEL
1731 CATALPA
CARLSBAD CA 92009
PLAN CHECK EXPIRATION
PC# CB973504 DATE: 11/17/98
ADDRESS: 1731 CATALPA RD
You have applied to have your plans checked on the date shown
above, and you have not obtained your building permit.
The provisions of Section 304(d) of the Uniform Building Code
state:
"Section 304(d) Expiration of Plan Review
Applications for which no permit is issued
within one year following the date of
application shall expire by limitation, and
plans and other data submitted for review
may thereafter be returned to the applicant
or destroyed by the Building Official.
In order to renew action on an application
after expiration, the applicant shall resubmit
plans and pay a new plan review fee."
Please check the appropriate box indicating your choice
and return this letter to the BUILDING DEPARTMENT.
PROJECT ABANDONED. I WILL PICK UP PLANS WITHIN 10 DAYS.
PROJECT ABANDONED. PLANS MAY BE DESTROYED.
If you have any questions, please contact the Building
Department at (619) 438-1161 extension 4331.
RAENETTE ABBEY
Building Department
2O75 Las Palmas Dr • Carlsbad, CA 92OO9-1576 * (76O) 438-1161 - FAX (76O) 438-O894
EsGil Corporation
In ^Partnership With government for Quitting Safety
DATE _ NOVEMBER 30, 1998 _ a APPLICANT
JURISDICTION _ CARLSBAD _ a PLAN REVIEWER
a FILE
PLAN CHECK NO 97-3504 _ SET *
PROJECT ADDRESS 1731 CATALPA ROAD _
PROJECT NAME CLARK ROOM ADDITION
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff
Tne plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
I | The applicant's copy of the check list has been sent to
Esgil Corporation staff did not advise the applicant that the plan check has been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted _ Telephone # _ _
Date contacted _ (by _ ) Fax # __ . _ _
Mail Telephone Fax In Person
REMARKS
PROJECT EXPIRED/ABANDONED. PLANS DESTROYED.
By KR Enclosures
Esgil Corporation
D GA D CM D EJ D PC trnsmHdot
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (619)560-1*68 4- Fax (619) 560-1576
EsGil Corporation
Professional fpfon Review Engineers
DATE 11/26/97
JURISDICTION Carlsbad
PLAN CHECK NO 97-3504 SET I
PROJECT ADDRESS 1731 Catalpa Rd.
PROJECT NAME Clark Room Addition
QI APPLICANTjQRig>
PLAN REVIEWER
a FILE
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes
The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department
staff
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck
The check list transmitted herewith is for your information The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person
The applicant's copy of the check list has been sent to
Peter Martin
1106 2nd St Encinitas, Ca 92024
Esgil Corporation staff did not advise the applicant, except by mail, that the plan check has
been completed
Esgil Corporation staff did advise the applicant that the plan check has been completed
Person contacted Telephone #
Date contacted (by ) Fax #
Mail Telephone Fax In Person
REMARKS
By Mike Puckett
Esgil Corporation
D GA D CM D EJ D PC
Enclosures
11/18/97 trnsmtl dot
9320 Chesapeake Drive, Suite 208 * San Diego, California 92123 4- (619)560-1468 *• Fax (619) 560-1576
Carlsbad 97-35O4
11/26/97
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO 97-35O4 JURISDICTION Carlsbad
PROJECT ADDRESS 1731 Catalpa Rd.
FLOOR AREA SOOsqft STORIES 1
HEIGHT
REMARKS
DATE PLANS RECEIVED BY
JURISDICTION 11/17/97
DATE INITIAL PLAN REVIEW
COMPLETED 11/26/97
DATE PLANS RECEIVED BY
ESGIL CORPORATION 11/18/97
PLAN REVIEWER Mike Puckett
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building
Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state
laws regulating energy conservation, noise attenuation and access for the disabled This plan
review is based on regulations enforced by the Building Department You may have other
corrections based on laws and ordinance by the Planning Department, Engineering
Department, Fire Department or other departments Clearance from those departments may be
required prior to the issuance of a building permit
Present California law mandates that residential construction comply with Title 24 and the
following model codes 1994 UBC (effective 12/28/95), 1994 UPC (effective 12/28/95), 1994
UMC (effective 2/23/96) and 1993 NEC (effective 12/28/95)
The above regulations apply to residential construction, regardless of the code editions
adopted by ordinance
The following items listed need clarification, modification or change All items must be satisfied
before the plans will be in conformance with the cited codes and regulations Per Sec 106 4 3,
1994 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e.. plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
LIST NO 1, GENERAL SINGLE FAMILY DWELLINGS AND DUPLEXES WITHOUT SUPPLEMENTS (1994 UBC) r3forw dot
Carlsbad 97-3504
11/26/97
1 Please make all corrections on the original tracings, as requested in the correction
list
Submit three sets of plans for commercial/industrial projects (two sets of plans for
residential projects) For expeditious processing, corrected sets can be submitted
in one of two ways
1 Deliver all corrected sets of plans and calculations/reports directly to the City
of Carlsbad Building Department, 2075 Las Palmas Drive, Carlsbad, CA 92009,
(619) 438-1161 The City will route the plans to EsGil Corporation and the
Carlsbad Planning, Engineering and Fire Departments
2 Bring one corrected set of plans and calculations/reports, to EsGil
Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (619) 560-
1468 Deliver all remaining sets of plans and calculations/reports directly to the City
of Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments
NOTE Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete
2 Identify the sheets of the plans i e 1,2,3
3 All sheets of plans must be signed by the person responsible lor their preparation
(California Business and Professions Code)
4 Plans, specifications and calculations shall be signed and sealed by the California
state licensed engineer or architect responsible for their preparation, for plans
deviating from conventional wood frame construction Specify expiration date of
license (California Business and Professions Code) See item 21.
5 Specify on the Title Sheet of the plans the gross floor area of the room addition
Section 10633
6 Provide a statement on the Title Sheet of the plans that this project shall comply
with Title 24 and the 1994 UBC, UMC and UPC and the 1993 NEC
7 Note on plans that smoke detectors are to be installed in all existing bedrooms and
hallways leading to the bedrooms
8 Glazing in the following locations should be of safety glazing material in accordance
with Section 2406 4 (see exceptions)
9 Fixed and sliding panels of sliding door assemblies and panels tn swinging doors other
than wardrobe doors
10 Show 3'0" landing at the exterior of each door of the room addition
11 Specify roof slope
Carlsbad 97-3504
11/26/97
12 Specify on the plans the following information for the roof materials, per Section
10633
• Manufacturer's name
• Product name/number
• ICBO approval number, or equal
13 Provide skylight details to show compliance with Sections 2409 and 2603, or specify
on the plans the following information for the skylight(s), per Section 106 3 3
• Manufacturer's name
• Model name/number
• ICBO approval number, or equal
14 Show 6" wood/earth separation at detail 4 sheet ?
15 Note on plans that surface water will drain away from building and show drainage
pattern and key elevations Section 1804 7
16 Show foundation sills to be pressure treated, or equal Section 2317 4
17 Make Minimum Construction Specification sheets part of the plans
18 Show stud size and spacing
19 Note on the plans that an A I T C Certificate of Compliance for glued laminated
wood members shall be given to the building inspector prior to installation Section
2305
20 Show wall bracing Every exterior wood stud wall and main cross-stud partition shall
be braced at each end at least every 25 feet of length Section 2326 113 and Table
23-l-W
21 Provide calculations from a licensed Engineer/Architect for the laminated timber at
addition/new room addition, for 2x8 ridge beam at vaulted ceiling in room addition,
and for 4x16 beam proposed to support ridge beam Show required footing sizes
Have Engineer/Architect stamp seal and sign calculations and all structural sheets
of plans
22 In open beam construction, provide strap ties across the beams at the ridge
support Section 2303 8
23 Show how room addition is to be heated i e extend duct
24 Show existing fireplace is 2'-0" above a point 10'-0" away al new room addition
roof
25 Show on floor plan all receptacle locations and switch controlled light/light
receptacle
Carlsbad 97-35O4
11/26/97
26. ENERGY CONSERVATION
27 Provide plans, calculations and worksheets to show compliance with current energy
standards
28 The regulations require a properly completed and properly signed Form CF-IR to be
either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to
allow the building inspector to readily compare the actual construction with the
requirements of the approved energy design
29 All energy items shown on the plans must be in agreement with the information
shown on the properly completed Form CF-IR
30 Specify on the building plans all of the mandatory energy conservation requirements
as listed on the enclosure titled, "Mandatory Measures Checklist"
31 Show the make, model, type and efficiency of the space heating (or cooling) system
32 For room additions, show compliance with the energy standards See attached
33 Provide fluorescent general lighting (40 lumens per watt minimum) in kitchen(s) and
bathrooms
34 Provide a note on the plans stating "All new glazing (fenestrations) will be installed
with a certifying label attached, showing the U-value "
35 Show on the Title Sheet on the plans, the information required by the attached
Developmental Services Sheet 4797
To speed up the review process, note on this list (or a copy) where each correction
item has been addressed, i e , plan sheet, note or detail number, calculation page,
etc
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list If there are other changes, please briefly describe
them and where they are located in the plans
Have changes been made to the plans not resulting from this correction lisf? Please
indicate
Yes Q No a
Carlsbad 97-35O4
11/26/97
The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake
Drive, Suite 208, San Diego, California 92123, telephone number of 619/560-1468,
to perform the plan review for your project If you have any questions regarding
these plan review items, please contact Mike Puckett at Esgil Corporation
Thank you
'; (" ' ' *•< > ' (Reference: UBC 1994 Edition)"
These'are. fnmTmnfn 'spccificadons established by the Uniform Building Code and shall not supersede any more rcstricth
specificitio"ns shown on the approved plans.
A. Foundation and UrxJcrfioor
1,
2.
3.
Concrete: for footings shall have a minimum
compresswc strength of 2000 psi at 23 days and
gfratt be composed of 1 part cement, 3 parts sand,
4 pans 1" maximum size roclc, and oot more than
1 1/2 gallons of water per sack of cement.
Wood'" and Earth Separation: Foundations
supporting wood *fra11 extend at least 6" above the
adjacent finish grade (Sec. 1806.1) Provide 18"
clearance under wood joists and 12" clearance
under wood girders. (Sec. 2317.3)
Concrete Slabs: Slabs oa grade shall be at least 3
1/2- thick. (Sec. 1924)
4. i reaied Wood: All foundation plates or sills and
sleepers oa concrete slab* in direct contact with
earth, and sills which rest on coDcrete or masonry
foundations, shall be treated wood or approved
wood of nztnral resistance to decay as listed in
Section 2317.4.
5. Anchor Bolts a*vi Footing Sills: Foundation pUies
or sills shall be bolted u> the foundation or
foundation wall with cot less i^?n 1/2" by 10*
steel bolls embedded at least 7" into concrete or
masonry and spaced not more than 6' apart.
There shall be a minimum of two bolts per piece
with one bolt located within 12" of each end of
each piece. (Sec. 1806.6)
6. ' Uaisrflccr Ye^aladon: Undcrfloor areas stall be
Yentilaied by HH approved mechanical means or
by ope"!'"*gs in foundation walls. Vent openings
shall ha\ e a riet area of not less than 1 sq ft for
each 150 sq ft of underfloor area. The openings
shall be arranged to provide cross ventilation and
7.
shall be approximately equally distributed aJor.
at least two sides of the building. At each *a
line containing vents at least one vent should b
located as close as practical to building comer'
Vents shall be covered with corrosioa-rcsisia:
wire mesh with mesl* openings' of 1/4" i
dimension. (Sec. 2317.7)
- ' - - - r - •' . ,
Undcrnoor Ai^ess: Undcrnoor areas shall t
accessible by a crawl hole not less that IS" t
24", unobstructed by pipes, ducts or simil
construcDon. (Sec. 2317.3)
B. Wood Framing
1. Lumber: All Joists, rafters, beams and posts 2" -
4" thick shall be No. 2 grade Douglas Fir-Larc
or bener. All posts and beams 5* and thicker sh:
be No. 1 grade Douglas Fir-Larch or berier. (S
item B.15 for grade requlrcmcnis for studs.)
2. Braced wall Lines: Buildings shall be provjd
with exterior and interior braced wall line
Spacing sh?11 not exceed 25 feet oa center in bo
the longitudinal and transverse directions in es
story. (Sec. 2326.5.1) Bracing sMl comply wi
the requirements of U.B.C. Sec. 2326.1*1.3.
3. Cross Bridging: Floor joists and rafters 12"
more in oepth and spanning more than 3' shall
supported laterally by bridging or full dep
blocking at intervals not exceeding S' unless:
a) Both edges of me- member are held in line t
b) The compression edge of the member
supported throughout Its length to prcv
la'-eral displacement, as by adequate sheaih.
or subilcoring, and the ends and all points
* v- (*
ait- bearing' have,- lateral, support to prevent
"v? rotation! (SecY2306.7) -
4. X» Provide blocking at exxSi'ind allsupports of floor
joists and rafters; (Sec. 2325.8.3)
5. Provide solid blocking at the ridge Hoc and at the
* ctterior walls of truss roofs.
6.^ Double Joists: Floor joists shall be doubled under
bearing partitions running parallel over joists.
(Sec. 2326.8.5)
7. Rafter purlin braces arc to be not less than 45
degrees to the horizontal. The unbraced length of
purlin braces shall not exceed 8'. In no case shall
purlins be smaller than the supported rafters.
(Sec. 2325.12.7)
S. Rafters shall be framed directly opposite each
other at the ridge. Hips, valleys and ridges should
be 2" nominal thickness and not less in depth than
the cut cod of the rafters. (Sec. 2326.12.3)
9. Rafter Ties: Rafter tics shall be placed not more
than 4* on center where rafters and ceiling joists
are not parallel. Rafter tics snail be not more than
24-" on center with tile roofing. Rafter ties shall
be provided as low as possible on each rafter pair.
(Sec. 2325.12.6)
10. Provide 1/2" minimum clearance between top
plates of interior non-bearing partitions and
bonom chords of trusses.
11. Provide double top plates with minimum 4S" lap
splice. (Sec, 2325.11.2)
12. Nailing will be in compliance with Table 23-I-Q
of the U.3.C. (See sheet 5 of this form)
13. Firestopoiag shall be provided in the following
locations": (Sec. 708.2.1)
a) In concealed spaces of stud walls and
partitions including furred spaces at the
ceiling and floor levels and at 10' intervals
both horizontal and \ertical.
EXCEPTION: Fire stops may be omitted at
floor ai>j ceiling levels when approved
Ed ok:-actuated fire dampers arc installed at
these Ie\els.
b) At all iniercannectioris between concealed
•vertical 2-Dd horizontal spaces such as occur
u sorr.'-s, drop ceilings and cove ceilings.
c) In concealed spaces between stair stringers at
. the top and_bouom of the run and between.
,, Ktudi^aJong "and In lino' with the" fun of the : "
- stairs' if, the* walls1 uoder~ the"- stairs *are
unfinished."
d) In openings around vents, pipes, chimneys,
fireplaces and similar openings which afford
a passage for fire al ceiling and floor levels,
with non-combustible materials. " *
e) At openings between attic spaces and cHmrcy
chases for factory-built chimneys.
0 Where wood sleepers arc used for laying
wood flooring on masonry or concrete fire-
resistive floors, the space between the floor
slab and the underside of the wood flooring
shall be filled with noncombustible material
or fire blocked in such a manner that there
will be no open spaces under the flooring
which will exceed 100 sq ft in area and such
space shall be filled solidly under all
permanent partitions so rhat there is no
communication under flooring between
adjoining rooms.
EXCEPTIONS:
1. Fire blocking need not be provided in such
floors when at or below grade level in
gymnasiums.
2. Fire blocking need be provided only at the
Juncture of each alternate lam and at the ends
of each T?"g in a bowling alley.
14. Fire Block Construction: Except as provided in
item d, abo>e, RreblocVing shall consist of 2"
nominal lumber or two thicknesses of 1" nominal
lumber with broken lap joints or one thickness of
23/32 irch wood structural panel with joints
backed by 23/32 inch wood structural panel or
ons thickness of 3/4 inch Type 2-M particlebcard
wiih joints backed by 3/4 inch Type 2-M
particleboard.
Fire blocks may also be of gypsum board, cement
asbestos board, mineral fiber, glass fiber or other
materials securely fastened in place. Loose-fill
insulation maxtrial shall not be used as a fire
block unless specifically fire tested.
Walls having parallel or staggered stnds for
EOJod-transmission comrol shall have fire blocks
of mineral fiber or glass fiber or other approved
d materials. (Sec. 70S.2 2)
15. Studs: In one or two story buildings, scuds for
exterior waJls and interior bearing avails shall be
Dot less than 2"x4" zi Dot inore than 16"^ on
ccn:=r. Scuds for interior Don-bearing partitions
may be 2"x3" si 16" oa center. Sruds not mor:
S 2 ofS
Yvjooe floor and a roof, Suids longer than 8' shall be
. ;'i-jl Noi 2 grade, Douglas Fir-Larch or better.
16." An A.I.T.C. Certificate'of Conformancc for
,-. glued laminated wood members sJiall be given to
the Builfling Inspector prior to framing inspection.
C. General Material Specifications
3. Mortar Mix: Mortar to be used on construction of
masonry, walls, foundation walls, and retaining
walls shall consist of 1 part portland cement, 3
.- 1/2 parts sand, and 1/4 to 1/2 part hydratcd lime.
2. Grout Mix: The mix for grout shall be 1 part
ponland cement, 2 to 3 parts sand, 1/10 part
hydratcd lime, and "2 parts gravel. Grout shall
attain a minimum comprcssivc strength of 2000
psi at 28 days.
3. Masonry: The masonry units shall comply with
A.S.T.M* Spec. C90, Grade N, for hollow unit
concrete blocks.
4. Reinforcing Steel; The reinforcing steel used in
construction of reinforced masonry or concrete
structures shall be deformed and comply with
A.S.T.M. Spec. A615. Grade 40.
5. Structural Steel: Steel used as structural shapes
snch as wide flange sections, channels, plates,
angles shall comply with A.S.T.M. Spec. A35.
Pbc columns shall comply with A S.T.M. Spec.
A53. Structural cubes shall comply with
A.S.T.M. Spec A500, Grade B.
D. Roofing sod Weaiherproofing
1. Wood Siding: All wood siding shall be placed
over an approved Wcamel-proofing barrier of 153
felt, m'ni'-rium. (Sec. 1402.2)
2. Flashing Arourxl Openings: Every opening in any
exterior wall shall be flashed with sheet metal or
was±r proof building paper. (Sec. 1402.2)
3. All flashing, counter flashing and coping, when
of meul, sh?11 be of not less than No. 26 U.S.
gauge corrosion-resistant metal. See Sec. 1508 for
roof valley flashing requirements. At the juncture
of rcof and vertical surfaces, flashing and
counirrilashing shall be provided as required in
Sec. 1509.
4. Rcof Co-verirj*: All roof covering shall be
installed per applicable reouircments of Tables
1531, 1532, 15C, 15D1, 15D2, and 15E. Roof
coseriag must inert the requirements for a Class
"A" ranng for residential structures and a Class
"3" rtiirg for commercisJ structures
5. Unless roofs arc islopcd to drain over edges or arc
designed*. to\suppprti accumulaied, water;"} roof-
drains" shall be install ed' at' cleft l6Tw'"polnl of the "
roof.1 Roof drains' shall bo /adequate in size to
convey the water tributary, to tho roof drains.
Where roof drains arc required, overflow drains
having the same size 'as the roof drains shall be
installed with the folct flow line located 2""above
the low point of the roof, or overflow scuppers
having three times the size of the roof drains may
be installed la' adjacent parapet walls with the
inlet flow line located 2" above the low point of
the adjacent roof and having a minimum opening
tcight of 4*. Overflow drains shall be connected
to drain lines independent from the roof drains.
Roof drains and overflow drains, when concealed
within the constructioa of the building, shall be
installed in accordance with the Uniform
Plumbing Code Sec. 306.2. (Sec. 1506)
6. Foundation walls enclosing a basement below
finished grade shall be dampproofed outside by
approved methods and materials. (Sec. 1402.4)
7. Attic ventilating area shall be not less rha.n 1/150
of the area of me space ventilated, except that the
area may be reduced to 1/300 provided a! least 50
percent of ths ventilating area is located a
minimum of 31 above eave or cornice vents with
the balance of the required ventilation provided by
cave and/or cornice venis. The openings shall be
covered with, corrosion-resistant metal mesh with
mesh opcninE,s of 1/4" in dimension. (Sec.
1505.3)
8. Weep Screed: A weep screed with a minimum
vertical pnarhfra flange of 3 1/2" shall be
provided ai or below the foundation plateline for
all exterior sud walls finished on the exterior
•with stucco. The screed shall be placed a
rninvrmirrt of 4" above grade or 2" above paved
areas, (Sec. 2506.5)
E. General
1. Attic Access: Attic areas shall be accessible by ar
opening no less than 22" X 30". (Sec. 1505.1
U.B.C.) With a furnace in the attic, the opening
shall be not less than 22" x 36" or 30" X 30-
(Sec. 319.3 U.M.C.)
2. Shower Enclosures: Shower walls must^ b
finished to 2 height of 70" above the drain inlr
wim Emoom,, hard, Don- absorbent surfaces. (Stc
807. 1 .3) Glazing used in •* alls, ooors and pane
of shower and baihtub cDclosures shall be full
tempered, laminated safer/ glass or
plastic. (Sec. 2406,4)
Electric Meter Enclosure: Coniact S^n Diego G
and Electric Company, Customer E^iensi
Planning Department for cicvcr location. /
•airing rnust comply *iih the currcmly ado?1-
edition of ihc Naiioc^l Electric Code.
4. S&okc Detectors: (Sec. 310.9.1)
a)'1 Dwclling^unils, congregate residences and
-; is. hotel or lodging house guest rooms^ihat arc1 \iucd for'slceping"purposes shall be provided
, with smoke detectors, j Detectors shall be
- installed tnTiccordancc with the approved
manufacturer's instructions*
b) In new construction, required smote oVtcctors
shall receive their primary power from the
building wiring when such wiring is served
- fromc a commercial source and shall be
.. equipped with a banery backup. The detector1 ' shall emit a signal when the banrries arc low.
Wiring shall.be permanent and without a
disco injecting" switch other than those
required for overcurrcnt protection. Smoke
detectors may be solely battery operated when
installed in existing buildings; or in buildings
without commercial power; or in buildings
which undergo alterations, repairs or
additions enumerated below.
c) Wheu the valuation of an addition, alteration
or repair to a Group R Occupancy exceeds
$1000.00 (except repairs to exterior surfaces)
and a permit is required, or when one or
more sleeping rooms are added or created in
existing Group R Occupancies, smoke
detectors shall be installed in accordance with
the folio?.ing:
In dwelling units, a detector shall be installed
in e£c& sleeping room and at a point centrally
located in the corridor or area giving access
to tach separate sleeping area. When the
dialling unit h^s more than one story and in
dwellings wiih basements, a detector shall be
installed on each story and in the basement.
In (jTrelllrjj units where the story or basement
is split into two or more levels, the smoke
detector s*iM1 be installed on the upper level
except that when the lower level contains a
sleeping area, a detector shall be installed on
each level. When sleeping rooms arc on an
up^er level, the detector shall be placed at the
ceiling of the upper level in close proximiry
to the stairway. In dwelling units where the
ceiling height of a room open to the hallway
serving the bedrooms exceeds that of the
hallway by 24 inches or more, smoke
detectors shj-11 be installed in the hallway and
in the adjacent room. Detectors shall sound
an alana audible in all sleeping areas of the
d-s, tiling unit in ?,hich they are located.
In efficiency dwelling units, congregate
rcsiocDcc and twirl sleeping rooms, detectors
- shall bcjocaied on the ceiling or wall of the
main room'or, ctth'Xlwpihg'roorn^WKcn (,
sleeping room* wiuiinaif efficiency dwelling
unit or hotel suite arc oa an upper level, the
detector shall be placed at the ceiling of the
upper- level, in1, dose* proximity to the
stairway. When actuated, the detector shall
sound an alaroi audible within the sleeping
area of the dwelling unit or congregate
residence, hotel suite, or sleeping room in
which it is loc-ated.
Exit Facilities": Basements in dwelling units and
every sleeping room below the fourth story shall
have at least one operable window or exterior
door approved for emergency egress or rescue
which shall open directly into a public street,
public alley, yard or exit court. The emergency
door or window shall be operable from the inside
to provide a full clear opening without the use of
separate tools. All egress or rescue windows shall
have a net clear opening of 5.7 square feet. The
minimum net clear opening height dimension shall
be 24 inches. The net clear opening width
dimension shMI be 20 inches. Where windows are
provided as a means of egress or rescue they sh*11
have a finished sill height of not more rh?n 44"
above the floor. (Sec. 310.4) •
6. Glass ?n4 Glazing: Glass and glazing shall
comply with the provisions of Chapter 24 U.B.C.
Federal specifications may take- precedence. See
your glazing contractor.
7. Compaction reports arc required for all fill soils
over 12" depth. CCounty Grading Ord.)
8. If there are cuts or fills on the lot that are over 5
feet in height or if more than 200 cubic > arc's of
earth is moved, a grading permit is recruired. An
additional $500.00 fee, over and above the
grading permit and plan check fees will be
assessed for grading without a permit, (County
Grading Ord )
9. Natural drainage patterns shall not be altered in
av.b a v, ay as to concentrate or alter the point of
discharge for drainage flows. (County Grading
Ord)
. „ _ A -.r e
S^SaF#^'-~.1«»'rtii>*(A5?i»'^i*f'zfatpscv v* - ~f s~"rar}**;?- v 7 -_.;.-^v^^r *? .^ "-"-"
WffKS*BfiKS^*W<?!®8^5p5l55S^ *^ ?3*i '•Sf&fti&t&f*'*J. - '='i"V^H^W'^^STSK'r?^7^*'TF7Vi?*:'^»'' »- *-f»'» *SMfc !* ^ -• , i»--r- *, *r -^r ' >T . 1,rable2^1"<2gi Nailing Schedule (mtnimumunless otherwise noted) -
Nail Ing JA^V •---•-
Joist lo Jill or ruder, tocniij -
BridEinjtoJotit, tocnii] c*ch end
1" x 6" wbfkor or leu to «ch joist, faco rail
Wider than I* x &" subflcor to each joist, face naj
2' subfloor to Joist or prder, bliod aod face mil
Sole pttte to joist or btcckiBf , typlcil ficc niH
Sole ptiia Q jolxt or Noctin^, il bntcd will puxls
Top ptite to Bud, cud nail
Suid to"sols plua" - -
Double smdi, f^cc oul
Double top pliies, lypicil face mil -
Double top pktr*, lip splice
BlocHng bcMreca joisa or riftrn to tDp ptatt, toenail
Rim joist to top pUts, tocnail
Top pliir i, lips trd iarcncoions, ficc mil
Condnuou* header, two pieces
Ceiling joisa lo plus, toeniil
Condrcioui b&idrr to ttud, toenaH
Ceiling jotsa, lips over pmidoDi, ficc mil
Ceiling jolsa to pinl]=l riftcrs, ftee rail
Rifbr to ptitt, toerail
1 " brace to each sad rnd plus, fete nail
1" x 8" cbcidnng or leti to each bearing, face nail
Wider fcia 1* x 8" chr-artiing to each tciricg, fxcs nail
Built-up carter
Built-up girdir ind ^-^^e
Wood stnKsani partis and pardclebcard: *
S^bflcor, rcof iM wall «^^»T^;-^O (to framing):
1/2." ard !:*s
19/32" to 3/4"
7/S" o 1-
1 1/8" a 1 1/4"
Conbiiiaoa subnoor-u^dcrisj-rasm (to framing):
3/4" z^d I=ss
7/S' to I"
_ 1 1/5- to 1 1/V
Pasil S«lig (o framing):
1/2" or less
5/S-
Fibertcarf Sbiif^ig: 7
1/2"
25/32-
1/4-
3/S"
2-Sd
2-Sd
3-8d
2-1 6dI£ditl6'oc.
3-1 6d per 16'
2-1 6d
-4-Sd, toenail, or 2-16d, end nail
16d«24"o.c.
I6d it 16' o.c.
8-16d
3-Sd
Ed al 6" o.c.
2-1 fid
16d tt 16" o.e. along each edge
3-Sd
4-Sd
3-I6d
3-16d
2-Sd
3-Sd
16dat24"o.c.
2-1 6d u each bearing
2Cd xi 32" o.c. n top and booom lad saggered 2-20d
Sd ' or 6d «
Ed 2
lOd'orSd*
lOd ' or Sd *
Sd*
No. 11 g*. «, 6d ». No. 16 gx. *
No. llga. », Sd', No. 16ga."
6d1
: ends and at each
Notes:
* Cocinwa or bcx rails mjzy be used except where otherwise. Coa^noa or deforced
suons exceu 6" DQ cncrr H edgos, 12" at ttrm
d »-d particleboajd di*.;^?*^" *^ s* CorrosioD-misstnt siding or ca^'"; nails conforming to tbe rsquircnjeiiis of Seciion 2325.1.
cept 6" at all suorts where spans ir= 4S" or nore. For rgilirg
walls, refer to Sec.2314.3. Nails for wall sheathing miy be coupon,
of woocbox or casing
ng a^)d 1 3/4" kngm for 25/32" she,
and 1 1/2" k=srh for 25/32"
7 Fasi-ners spaced 3" oa eerier al extrnor edges aoJ 6" oa cercer xl inl±nneda.l£ supports.
* Corrosioa-rcsisorj roofing yjilt uidi 7/16 dlameicr bead and 1 1/2" Icngdi for 1/2"
conforming ta lie rtquiremena of Sec. 2325 1.* Corrcoca-resisant scaples widi rominil 7/16" crown »rcl 1 1/S" length for 1/2"
to tne requirements of Seeaan 2325.1. . . ,-• ^ ~<** Pirel s^ppom a: 16" [20" if s^enph axis in tne king direcdoa of the panel, mir-K odserwua naux=dj. C^i=g or ftnisa calls
edges, 12" al in-irmediiis suppons.11 Panel support u 24". C»^ng or finlih r^ils gparj^d 6" oa ptml edges, 12" al Hie
6 ra
NOTICE;of foe xporc^ sd ptzns u-bea SaelM-d wii tbe appnT»Tj of tbe cxcs=rj=ic'a permit. Cor^JJ=a =
im crsrcScaaons a« made i part of the pUns for tia proposed buJdin£(s) U be locaisd it _
or Pcr=jt FJ= N
of.
O*-rcr or Conmior
Carlsbad 97-3504
11/26/97
VALUATION AND PLAN CHECK FEE
JURISDICTION Carlsbad
PREPARED BY Mike Pucfcett
BUILDING ADDRESS 1731 Catalpa Rd.
BUILDING OCCUPANCY R3
PLAN CHECK NO 97-3504
DATE 11/26/97
TYPE OF CONSTRUCTION VN
BUILDING PORTION
Room Addition
Air Conditioning
Fire Sprinklers
TOTAL VALUE
BUILDING AREA
(ft2)
300
VALUATION
MULTIPLIER
94
VALUE
($)
28,200 00
28,200 00
S3 1991 UBC Building Permit Fee D Bldg Permit Fee by ordinance $ 27800
[X] 1991 UBC Plan Check Fee D Plan Check Fee by ordinance $ 18070
Type of Review D Complete Review Q Structural Only Q Hourly
Q Repetitive Fee Applicable D Other
Esgil Plan Review Fee $ 14456
Comments
Sheet 1 of 1
macvaluedoc5196
V
X."
City of Carlsbad
Engineering Department
DATE
BUILDING ADDRESS
PROJECT DESCRIPTION
ASSESSOR'S PARCEL NUMBER
BUILDING PLANCHECK CHECKLIST
PLANCHECK NO
/ Ort~fajjte<^ /W,
EST VALUE &J?
ENGINEERING DEPARTMENT
APPROVAL
The item you have submitted for review has been
approved The approval is based on plans,
information and/or specifications provided in your
submittal, therefore any changes to these items after
this date, including field modifications, must be
reviewed by this office to insure continued
conformance with applicable codes Please review
carefully all comments attached, as failure to comply
with instructions in this report can result in
suspension of permit to build
A Right-of-Way permit is required prior to
construction of the following improvements
DENIAL
Please see. the- attached report of deficiencies
marked withlaCMake necessary corrections to plans
or specifications for compliance with applicable
codes and standards Submit corrected plans and/or
specifications to this office for review
By
By
Date
Date
By
FOR OFFICIAL USE ONLY
ENGINEERING AUTHORIZATION TO ISSUE BUILDING PERMIT
Date
ATTACHMENTS
Dedication Application
Dedication Checklist
Improvement Application
Improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-Way Permit Application
Right-of-Way Permit Submittal Checklist
and Information Sheet
Sewer Fee Information Sheet
ENGINEERING DEPT CONTACT PERSON
Name Michele Masterson
City of Carlsbad
Address 2075 Las Palmas Dr, Carlsbad, CA 92009
Phone (619) 438-1161, ext 4315
CFD INFORMATION
Parcel Map No
Lots
Recordation
Carlsbad Tract
A-4
ULAS PAL^^AS\SVS^LIBRARY\gNG\WORDCOCS\GtJKLST^B^l^dlngP^ancheckC^ilslBPOQ01 F_nmiMM_di>c ^-.
RWOWMP^-,,- Las Pa|mas Dr . Carlsbad, CA 92OO9-1576 - (619) 438-1161 • FAX (619) 438-O894
*
BUILDING PLANCHECK CHECKLIST
Q
SITE PLAN
1 Provide a fully dimensioned site plan drawn to scale Show
A North Arrow
B Existing & Proposed Structures
C Existing Street Improvements ^
2 Show on site plan
D Property Lines
E Easements ^
F Rtght-of-Way Width,& Adjacent Streets
G Driveway widths^
A Drainage Patterns
1 Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course
2 ADD THE FOLLOWING NOTE "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building "
B Existing & Proposed Slopes and Topography
3 Include on title sheet
A Site address
B Assessor's Parcel Number
C Legal Description
For commercial/industrial buildings and tenant improvement projects, include
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc ) previously approved
EXISTING PERMIT NUMBER DESCRIPTION
DISCRETIONARY APPROVAL COMPLIANCE
Q Q 4a Project does not comply with the following Engineering Conditions of approval for
Project No
Q Q Q 4b All conditions are in compliance Date
\\LASPALMAS\SYS\LIBRARYlENG\WORD\DOCS\CUKLSTBuiKHng PlancHecK Cklst BP0001 Form MM doc _
Rev OBJ03J87
BUILDING PLANCHECK CHECKLIST
DEDICATION REQUIREMENTS
4 STV oNDy oRD/\ Z •$
Q Q Q 5 Dedication for all street Rights-of-Way adjacent to the building site and any storm
dram or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ , pursuant to Carlsbad
Municipal Code Section 18 40 030
Dedication required as follows
Dedication required Please have a registered Civil Engineer or Land Surveyor
prepare the appropriate legal description together with an 8 Vz x 11" plat map
and submit with a title report All easement documents must be approved and
signed by owner(s) prior to issuance of Building Permit Attached please find an
application form and submittal checklist for the dedication process Submit the
completed application form with the required checklist items and fees to the
Engineering Department in person Applications will not be accept by mail or fax
Dedication completed by Date
IMPROVEMENT REQUIREMENTS
\
Q 6a All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the
construction exceeds $ , pursuant to Carlsbad Municipal Code
Section 1840040
Public improvements required as follows
a
improvement requirements A registered Civil Engineer must prepare the
Attached please find an application form and submittal checklist for the public
appropriate improvement plans and submit them together with the requirements
on the attached checklist to the Engineering Department through a separate plan
check process The completed application form and the requirements on the
checklist must be submitted in person Applications by mail or fax are not
accepted Improvement plans must be approved, appropriate securities posted
and fees paid prior to issuance of building permit
Improvement Plans signed by Date
Q Q Q 6b Construction of the public improvements may be deferred pursuant to Carlsbad
Municipal Code Section 1840 Please submit a recent property title report or
current grant deed on the property and processing fee of $ so
we may prepare the necessary Future Improvement Agreement This agreement
must be signed, notarized and approved by the Cily prior to issuance of a
Building permit
Future public improvements required as follows
UlJ*SPALMAS\SYS\LIBRAR'AENG\WORD\DOCSOdKLST\Buikling Planchecfc Cfclst BROOCH Form MM doc -
Rev 09/03/97
BUILDING PLANCHECK CHECKLIST
pnd/ ord/
Q Q 6c Enclosed please find your Future Improvement Agreement Please return
agreement signed and notarized to the Engineering Department
Future Improvement Agreement completed by __
Date _
Q Q 6d No Public Improvements required SPECIAL NOTE Damaged or defective
improvements found adiacent to building site must be repaired to the satisfaction
of the City Inspector prior to occupancy
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11 06 030 of the Municipal Code
Q Q 7a Inadequate information available on Site Plan to make a determination on grading
requirements Include accurate grading quantities (cut, fill import, export) Write
"No Grading" on plot plan if none is required
Q Q 7b Grading Permit required A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached NOTE The Grading Permit must be issued and rough grading
approval obtained prior to issuance of a Building Permit
Grading Inspector sign off by Date
Q a 7c Graded Pad Certification required (Note Pad certification may be required even
if a grading permit is not required )
Q Q 7d No Grading Permit required fjCO (% /
Q Q Q 7e If grading is not required, write "No Grading" on plot plan
MISCELLANEOUS PERMITS
Q Q Q 8 A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way Types of work include, but are
not limited to street improvements, tree trimming, driveway construction, tieing
into public storm dram, sewer and water utilities
Right-of-Way permit required for
ttLASPAl_MAS\SYS\LIBRARY\ENG\WORD\DOCSVCUKLS'nBL>ildmD Plancheck Chlst BP0001 Form MM doc _
Rev 09/03/97
BUILDING PLANCHECK CHECKLIST
4&\J pnd^ ord/
Q Q Q 9 A SEWER PERMIT is required concurrent with the building permit issuance The
fee is noted in the fees section on the following page
U Q Q 10 INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Cammo Real, Carlsbad, CA 92008 District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List You may telephone (760) 438-2722, extension 153, for
assistance
Industrial Waste permit accepted by __
Date
Q Q 11 NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to
discharge to sensitive areas Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first
12 Q Re'quired fees are attached
fees required
Q Q a 13 Additional Comments:
\\LASPALMA5\SYSMJBRARY\ENG\WORD\DOCS\CtlKLS'nBuiiaing PlanchecK Cklsl BP0001 Form MM doc _
Rev 09/03/97
O
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST
Plan Check No. CB
Planner
Address /"73/
Van Lvnch Phone (619) 438-1 1 61 , extension 4325
Type of Project and Use:
Zoning: &~( General Plan.
>S*t>t>Project Density • — -~
Facilities Management Zone1
CFD
OrcleJ3ne of participation:Remaining net dev acres
(For non-residential development: Type of land used created by
this permit-
Legend:Item Complete ( I Item Incomplete - Needs your action
Environmental Review Required: YES NO /K TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action
Conditions of Approval'
Discretionary Action Required:
APPROVAL/RESO. NO.
PROJECT NO.
YES NO/C TYPE
DATE
OTHER RELATED CASES'
Compliance with conditions or approval' If not, state conditions which require action
Conditions of Approval:
Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES
CA Coastal Commission Authority? YES
If California Coastal Commission Authority Contact them at - 3111 Cammo Del Rio North, Suite
200, San Diego CA 92108-1725, (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed7
If NO, complete Coastal Permit Determination Form now
Coastal Permit Determination Log #:
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
Floor Plans).
2) Complete Coastal Permit Determination Log as needed.
\
0
Inclusionary Housing Fee required: YES
(Effective date of inclusionary Housing Ordinance - May 21, 1993 )
NO
Data Entry Completed? YES NO
(Enter CB #, UACT, NEXT12, Construct housing Y/N, Enter Fee Amount (See fee schedule for amount), Return)
Site Plan:
1. Provide a fully dimensional site plan drawn to scale Show. North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines
2. Provide legal description of property and assessor's parcel number
Zoning:
Y 1. Setbacks-
f \Front:
Interior Side:
Street Side:
Rear.
Required "L&
Required & '
Required -
Required (2.
Shown 2& '
Shown Sr f
Shown '
Shown Jv
^\ 2 Accessory structure setbacks:
Front.
Interior Side:
Street Side
Rear:
Structure separation.
l/\ 3 Lot Coverage:•
§C 4. Height:
£\ 5 Parking' Spaces
Guest Spaces
- f
JY _] Additional Comments fa
V
Required
Required , /
Required /-///I
Required ' f '
Required
Required ^—-T'C'gj
Required --^3^
Required £- —
Required AJ/A
£/e>fr(/jojx> <Z&TWOL
Shown
Shown , /
Shown /t//A
Shown
Shown
Shown </</O^
f '/ \Shown -£^-' IS (jt'i%>'Wrt\
Shown i —
Shown A^V
^^7 Of^ &XI1 77/JCt 7^u>o£-$@-&h*
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER