HomeMy WebLinkAbout1732 CEREUS CT; ; CB940734; Permit08/12/94 13:04
Page 1 of i
Job Address: 1732 CEREUS CT
Permit Type: RESIDENTAL ADD/ALT
Parcel No: 215-502-21-00
Valuation: 16,229
Construction Type: VN
Occupancy Group: R3
Description: 182 SF RES ADD
BUILDING ~p~E R M I T
Suite
Lot#:
Permit No: CB940734
Project No: A9401027
Development No:
Reference*:
Appl/Ownr DAVIDOVICH, PAUL
1732 CEREUS CT
CARLSBAD, CA 920081
8200 08/12/94 0001 01 02
C-PRMT 202.00Status: ISSUED
Applied: 06/16/94
Apr/Issue: 08/12/94
Entered By: DC
619 438^7328
*** Fees Required
** ****
Fees: 319.00Adjustments: 00 '
Total Fees: 319ioo
Fee description
Building Permit
Plan Check
Strong Motion Fee
* BUILDING TOTAL
Inter "Y" ^°r *lectric ^sue Fee' >tnter Y for Remodel s
* ELECTRICAL TOTAL
rees collected & c
Total Credits:
Total Payments:
: Balance Due:
- Units Fee/Unit
rredits ***
.00
. 117.00 !
202. 00
Ext fee Data
180. 00
117. 00
2. 00
299. 00
10 . 00 Y
10.00 Y
20. 00
ffp
CLEARAMC
AL APPROVAL, ,
^, HATF MM
F
°F907, T2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
PERMIT APPLICATION
City of Carlsbad Building Department
2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161
1. PERMIT TYPE
A - U Commercial U New Building U Tenant Improvement
B - D Industrial D New Building D Tenant Improvement
C-^Residential D Apartment DCondo D Single Family Dwelling ETAddition/Alteration
D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing
O Mechanical DPool D Spa Q Retaining Wall D Solar D Other
2. PROJECT INFORMATION
PLAN CHECK NO.
EST. VAL //£ , ^ % ^
PLANCK DEPOSIT'r f ' 1 fl
VALID. BY /?<^- ' '
DATE £?//&Z4 (S
C-PRMT 117.00
FOR OFFICE USE ONLY
Building or Suite No.
LEGAL DESCRIPTION Phase No.
CHECK BtUJW IF SUBMIT1ED:
D 2 Energy Calcs D 2 Structural Calcs D 2 Soils Report D 1 Addressed Envelope
ASSESSOR'S PARCEL EXISTING USE PROPOSED USE_
SQ.FT.STORIES
a. CONTACl PJ N lit ditterent rrom applicant.)
CITY STATE
ADDRESS
ZIP CODE
t/~t=. V
DAY TELEP:
DffAGE
HONE
4. APPLICANT
NAME
CITY
U CONTRACTOR U AGENT FOR CON IKAUIOR
ADDRESS
ZIP CODE
U OWNER STAGENT FOR OWNER
STATE DAY TELEPHONE
57PROPER1T OWNER
NAME
CITY STATE
ADDRESS /
ZIP CODE DAY TELEPHONE
6. GONTRACIUR
NAME
CITY STATE
STATE LIC. #
ADDRESS
ZIP CODE
LICENSE CLASS
DAY TELEPHONE
CITY BUSINESS LIC. #
STATE LIC. #
7. WOKKliKl> UUMFliNSA'nON
Workers' Compensation Declaration: I hereby ailirm that I have a certificate of consent to self-insure issued by the Director ot Industrial
Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified
by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C).
INSURANCE COMPANY POLICY NO.EXPIRATION DATE
Certificate ot Exemption: I certify that in the performance ot tne work tor which this permit is issued, 1 shall not employ any person in any manner
so as to become subject to the Workers' Compensation Laws of California.
SIGNATURE DATE
8. OWNER-BUILDER DECLARATION
Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractors License Law For the following reason:
D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or
offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds
or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended
or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden
of proving that he did not build or improve for the purpose of sale.).
D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions
Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects
with contractor^) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair
any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the
provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code)
or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit
subjects the applicant to a civil penalty of not more than five hundred dollars [$500]).
SIGNATURE DATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and
prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act?
D YES D NO
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district?
D YES O NO
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site?
D YES D NO
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT
HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
. UUNSrHiOlON LENDING AGENCY
l hereDy attirm that there is a construction lending agency tor the performance ot the work tor which tnis permit is issued (Sec 3097(i) Civil CJode).
LENDER'S NAME LENDER'S ADDRESS
10. APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct. I agree to comply with all City ordinances and State laws
relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection
purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS
AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SATO CTTY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over S'O" deep and demolition or construction of structures over 3 stories in height.
Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the
building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by
such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Codel
APPLICANT'S SIGNATURE DATE:,
WHITE: ^FUe YELLOW: Applicant PINK: Finance
— f k
PERMIT* CB940734
DESCRIPTION: 182 SF RES ADD
CITY OF CARLSBAD
INSPECTION REQUEST
FOR 10/13/94
TYPE: RAD
JOB ADDRESS:
APPLICANT:
CONTRACTOR:
OWNER:
1732 CEREUS
DAVIDOVICH, PAUL
CT
PHONE:
PHONE:
PHONE:
INSPECTOR AREA PY
PLANCK* CB940734
OCC GRP R3
CONSTR. TYPE VN
STE: LOT:
619 438-7328
REMARKS: MW/RES
SPECIAL INSTRUCT:
INSPECTOR
TOTAL TIME:
CD LVL DESCRIPTION
19
29
39
49
ACT COMMENTS
ST Final Structural
PL Final Plumbing 71
EL Final Electrical T
ME Final Mechanical J?
f )
Y
\\\
\
***** INSPECTION HISTORY *****
DATE DESCRIPTION
101294 Final Combo
092294 Interior Lath/Drywall
092194 Interior Lath/Drywall
092194 Exterior Lath/Drywall
092094 Insulation
092094 Frame/Steel/Bolting/Welding
092094 Rough Electric
091494 Roof/Reroof
091494 Shear Panels/HD's
090194 Ftg/Foundation/Piers
ACT INSP-
CA PY
AP PY
AP
AP
AP
AP
AP
AP
AP
AP
PY
PY
PY
PY
PY
PY
PY
PY
COMMENTS
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619)560-1468
DATE:
JURISDICTION:
PLAN CHECK NO:
7/ff/fV
yy-737
PROJECT ADDRESS: /?32-
PROJECT NAME; DAVIbOVHLH-
SET:
_J ft III * r "^m ^ -
_, JURISDICTION^
^JPLAN CHECKER
JFILE COPY
jUPS
^DESIGNER
D
D
D
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
cies identified &e.LOu are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
{| The applicant's copy of the check list has been sent to:
j^| Esgil staff did not advise the applicant contact person that
plan check has been completed.
I1 Esgil staff did advise applicant that the plan check has
— been completed. Person contacted:
Telephone #Date contacted:
REMARKS ctTY 7& PLACf, TH€l/^ SOILS WdT>C£o*J 77/g-
By:ESGIL CORPORATION
DGA DCM DPC
Enclosures:
UXr-
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619) 56O-14-68
DATE:
JURISDICTION: (VlAL3g/lP *" t3^LAN CHECKERQFILE COPY
PLAN CHECK NO: fV~ 73V SET: ~ZT DUPS
QDESIGNER
PROJECT ADDRESS; /732- C£,fc£,i>5 CT
PROJECT NAME:
D The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction's building codes when minor deficien-
' cies identified are resolved and
checked by building department staff.
D The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
rag-; The check list transmitted herewith is for your information.
^ The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
3SS PIKE. A(SE~ "£" CAALS&AO C4
[ ] Esgil staff did not advise the applicant contact person that
plan check has been completed.
||£j Esgil staff did advise applicant that the plan check has
been completed. Person contacted;
Date contacted: _ 7 /#/? y _ Telephone
REMARKS ;
By: p£~T£. f^/SCtt&z^ Enclosures:
ESGIL CORPORATION 7/;/
DGA DCM 0pc
JURISDICTION:_Date plans received by plan checker; 7 /(//*? V
PLAN CHECK NO.:
PROJECT ADDRESS:
TO: I
/— "73V -""Date plan recheck completed; "7//3/7V By;
1111- C^LEUS CT _
RECHECK PLAN CORRECTION SHEET
Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform
Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conservation, noise attenuation and disabled access. The plan check is based on regulations enforced
by the Building Inspection Department. You may have other corrections based on laws and ordinances
enforced by the Planning Department, Engineering Department or other departments.
The items shown below need clarification, modification or change. All items have to be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), of
the Uniform Building Code, the approval of the plans does not permit the violation of any state,
county or city law.
PLANS
Please make all corrections on the original
tracings and submit two new sets of prints,
and any original plan sets that may have been
returned to you by the jurisdiction, to:
0
&LJ)C-
To facilitate rechecking, please identify,
next to each item, the sheet of the plans
upon which each correction on this sheet has
been made and return this check sheet with
the revised plans.
The following items have not been resolved
from previous plan reviews. The original
correction number has been given for your
reference. In case you did not koop—a oopy
ef—the—prior—correction liat,—we—have
onolocod—those—pages—containing the atill
outstanding corrections. Please contact me
if you have any questions regarding these
items.
Please indicate here if any changes have
been made to the plans that are not a result
of corrections from this list. If there are
other changes, please briefly describe them
and where they are located on the plans.
Have changes been made to the plans not
resulting from this correction list? Please
check.
Yes No
S/
PS
(O)
SSTB AT
of
/A/
ALL
Ctrr TO PLAc^ T7/Tf//g sroi(A STTfri^P CW 77^
Form No. RPCS.41290
..Certificate of Compliance: Residential (Page 1 of 2) CF-1R
ProjaclTUlo
Project Addrew
Documentation Author
Compliance Method (Package,
Telephono
Data
Building Permit *
Plan Check/ Dale
Field Check / Dale
Point System or Computer) CllmatoZona Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area: ft2
Building Type: Single Family Addition
(check one or more) Multi-Family Existing-Plus-Addition
Front Orientation: North / East / South / West / All Orientations
(Input orientation in degrees and cirde one.)
Number of Dwelling Un'rts:
Floor Construction Type: Slab / Raised Floor (circle one or both)
BUILDING SHELL INSULATION
Construction
Component Insulation Assembly Location/Comments
Type R-Value U-Value (atlic, to garage^typical. etc.)
Wall
Wall
Roof :
Roof •-
Floor '..
Floor
Slab Edge....
FENESTRAT10N Shading Devices
Fenestratfon Area Fenestration Interior Exterior Overhang .. Framing Type' •
Orientation (sf) U-Value (roller blind, etc.) (shadascreen. etc.) (yes/no) (metal/wood/viriyl)
Front ( ) ______
Front ( ) • '
Left ( ) ~ ; • ' IZZZZZ- ' ZZZZILett. ( .) • ; ' • ZZZZZZI ZZZI ZZZZZ
Rear ( ) ZZZZ
Rear ( }
Right ( ) ; . ~~~ ~~~~L "
Right..,.. ( ) , ~ - ZZZI ZZZZISkylight
Skylight ; ~ —' ZZZZ ~
THERMAL MASS
Type/Covering Area Thickness
(slab/exposed, tila. etc.) (sf) (inches) Location/Description (kitchen, bath, etc.)
Riv[»*dJinuiry 19K
-Certificate of Compliance: Residential (Page 2 of 2)CF-1R
Project TUIe Date
HVAC SYSTEMS
Note: Input hydronic or combined hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat
(AFUE/HSPF) (ducls/anic. etc.) R-Value Type
Cooling Equipment
Type (air conditioner,
heat pump. evap. cooling)
Minimum
Efficiency
(SEER)
Duct
Location
(attic, etc.)
Duct Thermostat Configuration
R-Value Type (split or package)
WATER HEATING SYSTEMS
Water Heater Distribution
Type Type
Energy1 External
Rated1 Tank Factor or Tank
Number Input (kW Capacity Recovery Standby1 Insulation
in System or Btu/hr) (gallons) Efficiency Loss (%) R-Value
1. For small gas storage (rated input S 75.000 Btu/hr). electric resistance and heat pump water heaters, list Energy Factor.
For large gas storage water heaters (rated input 2 75.000 Btu/hr). list Rated Input. Recovery Efficiency and Standby Loss.
For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of
the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the
individual with overall design responsibility: Wh^n this certificate of compliance is submitted for a single building plan to be built in multiple
orientations, any shading feature that is varied is indicated in the Special Features/Remarks section.
Designer Or Owner (per Business & Professions Code)
Name:
Title/Firm: ___
Address:
Telephone:
Lie. *:
Documentation Author
Name:
Ti tie/Firm:
Address:
Telephone:
(signature)
Enforcement Agency
(date)
Name:
Title: [
Agency:
Telephone:
(signature)(date)
(signature/stamp)
RivltxJ Janutry 1992
(date)
Mandatory Measures Checklist: Residential MF-1R
NOTE: Lowrisa residential buildings subject to the Standards must contain these measures regardless ol the compliance
approach used. Items marked with an asterisk (•) may be superseded by more stringent compliance requirements
listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features
noted shall be considered by all parties as binding minimum component performance specifications for the
mandatory measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION DESIGNER ENFORCEMENT
Building Envelope Measures
* §150(a): Minimum l^W ceiling insulation. •
§150(b): Loose fill insulation manufacturer's labeled R-Va!ue.
* §150(c): Minimum R-13 wail insulation in framed walls (does not apply to exterior mass walls).
* §150(d): Minimum R-13 raised floor insulation in framed Roofs; minimum R-8 in concrete raised doors.
§150(1): Slab edge insulation • water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§113: Insulation specified or installed meets California Energy Commission quality standards.
Indicate type and form.
§115-17: Fenestration Products. Exterior Doors and Infiltratioa'Exfiltration Controls
a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
b. Manufactured fenestration products have label with certified U-vaiue. and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§ 150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(0: Special infiltration barrier installed to comply with §151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory-built fireplaces have:
a. Clcseable metal or glass door
b. Outside air intake with damper and control
c. Rue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(i): Setback thermostat on all applicable heating systems.
§150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater).
2. First 5 feet of pipes closest to water heater tank, non-recircutating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating sections of hot water system.
4. Cooling system piping below 55°F insulated.
5. Piping insulated between heating source and indirect hot water tank.
•§150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value ol R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
manually operated dampers..
§114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,
no electric resistance heating and no pilot HghL
2. System is installed with:
a. At least 36* pipe between filter and heater for future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no
continuously buring pilot light (Exception: Non-electrical cooking appliance with pilot < 150 Btu/hr.)
Lighting Measures
§150(k): 40 lumensAvatt or greater for general lighting in kitchens and rooms with water dosets; and
recessed ceiling fixtures 1C (insulation cover) approved.
vC • •
Revised Januiry 1992
I/"
ESGIL CORPORATION
9320 CHESAPEAKE DR., SUITE 208
SAN DIEGO, CA 92123
(619)560-14-68
DATF. 6/ Z.V/?L/ |J APPLICANT
BJURISDICTION
iPLAN CHECKER
QFILE COPY
PLAN CHECK NO: fV~73V SET: IT Qups
QDESIGNER
PROJECT ADDRESS: /73Z- C E f^B \J^ CT
PROJECT NAME: _ &A (/' OOWC H
The plans transmitted herewith have been corrected where
necessary and substantially comply with the jurisdiction's
building codes.
The plans transmitted herewith will substantially comply
with the jurisdiction1 s -building codes when minor deficien-
cies identified _ are resolved and
checked by building department staff.
The plans transmitted herewith have significant deficiencies
identified on the enclosed check list and should be corrected
and resubmitted for a complete recheck.
The check list transmitted herewith is for your information.
The plans are being held at Esgil Corp. until corrected
plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the
jurisdiction to return to the applicant contact person.
The applicant's copy of the check list has been sent to:
355 P/n(L A\/E- "e" CA^-LSBAQ CA-
Esgil staff did not advise the applicant contact person that
plan check has been completed.
Esgil staff did advise applicant that the plan check has
been comoleted. Person contacted:
Date contacted: Telephone £
REMARKS:
By: PtTt. FfSCtfoZ _ Enclosures:
ESGIL CORPORATION
DGA D CM
PLAN CHECK NO: <?<-/~ ~73 V FOREWORD; PLEASE READ
JURISDICTION: CITY OF CARLSBAD
TO:
ENCLOSURES:
PROJECT ADDRESS; /73>2-C7~
FLOOR AREA; + \bt~ C<t/ +_
STORIES : £-
HEIGHT:
REMARKS:
PLAN CORRECTION SHEET
CITY OF CARLSBAD
SINGLE FAMILY AND DUPLEX DWELLINGS
Date plans received by jurisdiction:
Date plans received by Esgil Corporation:
Date initial plan check completed:
By .
Applicant contact person-.
-7 to
_ Telephone : _
Plan check is limited to technical
requirements contained in the Uniform
Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National
Electrical Code and state laws regulating
energy conservation, noise attenuation
and access for the handicapped. The plan
check is based on regulations enforced by
the Building Inspection Department. You
may have other corrections based on laws
and ordinances by the Planning
Department, Engineering Department or
other' departments.
Present California law mandates that
residential construction comply with
Title 24 and the following model codes:
1991 UBC (eff. 8/14/92)
1991 UPC (eff. 8/14/92)
1990 NEC (eff. 7/1/91)
1991 UMC (eff. 8/14/92)
The above regulations apply to
residential construction, regardless of
the code editions adopted by ordinance.
The circled items listed need
clarification, modification or change.
All items have to be satisfied before the
plans will be in conformance with the
cited codes and regulations. Per Sec.
303 (c), 1991 Uniform Building Code, the
approval of the plans does not permit the
violation of any state, county or city
law.
To speed up the recheck process, note on
this list (or a copy) where each
correction item has been addressed i.e.,
plan sheet, specification, etc. Be sure
to enclose the marked up list when you
submit the revised plans.
NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED.
List No. 2, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1991 UBC)
PLANS
1.) Please make all corrections on the
V"""^ original tracings and submit two new
( sets of prints, to:
Esgil Corporation, 9320 Chesapeake
Drive, Suite #208, San Diego,
California 92123,
\ (619) 560-1468.
2 A Please make all corrections on the
V s original tracings and submit two new
sets of prints, to:
The jurisdiction's building
department.
Indicate on the Title Sheet of the
plans the name of the legal owner and
name of the person responsible for the
preparation of the plans.
Section 302 (a)7.
4.JA11 sheets of plans must be signed by
V ' the person responsible for their
preparation. (California Business and
Professions Code).
s*—x
( 5 .J Plans, specif ications and calculations
^yS shall be signed and sealed by the
/ California state licensed engineer or
/ architect responsible for their
/ preparation, for plans deviating from
/ conventional wood frame construction.
I Specify expiration date of license.
\ (California Business and Professions
V Code).•^
Specify on the Title Sheet of the
plans the gross floor area of each
element of this project, including
dwelling, garage, carport/ patio, deck
and balcony. Section 302(d).
Provide a statement on the Title Sheet
of the plans that this project shall
comply with Title 24 and the 1991 UBC,
UMC and UPC and 1990 NEC.
Submit fully dimensioned plot plan,
drawn to scale, showing location,
size, and uses of all existing and
proposed structures on the lot.
Identify property lines and show lot
dimensions and all easements. Section
302(d).
Indicate distance from property lines
to the proposed building. Section
302(d).
. On the cover sheet of the plans,
specify any items requiring special
inspection, in a format similar to
.that shown below. Section 302(c).
REQUIRED SPECIAL INSPECTIONS
In addition to the regular
inspections, the following checked
items will also require Special
Inspection in accordance with Sec.
306 of the Uniform Building Code.
ITEM REQ. IF
CHECKED
REMWKS
SOILS COMPLIANCE
PRIOR TO
FOUNDATION INSP.
STRUCTURAL CONCRETE
OVER 2500 PSI
PRESTRESSED STEEL
FIELD WELDING
HIGH STRENGTH BOLTS
EXPANSION ANCHORS
SPECIAL MASONRY
SPRAYED-ON FIRE
PROOFING
PILES/CAISSNS
DESIGNER-SPECIFIED
OTHER
11/18/93
12!.
i-
4
i-
Show on the title sheet all
structures, pools, walls, etc.
included under this application.
Any portion of the project shown on
the site plan that is not included
with the building permit application
filed should be clearly identified
as "not included."
Clearly show if the lower level is
a basement or a story, based on the
definitions in Sections 403 and 420.
Plot the finish grade (as defined)
on the elevations and dimension the
distance to the floor above, for
story determination.
FIRE PROTECTION
Exterior walls closer than 3 feet to
property lines shall be one-hour
rated construction and have no
openings. Table 5-A.
Exterior walls closer than 3 feet to
a property line shall have 30 inch
parapets when the floor area per
floor exceeds 1,000 square feet. See
Section 1710 for possible exception.
Projections, including eaves, may
not extend more than 12 inches into
the 3 foot setback from the property
line. Section 504(b).
Eaves over required windows shall be
not less than 30 inches from the
side and rear property lines.
Section 504(a).
Projections, including eaves, shall
be one-hour fire-resistive
construction, heavy timber or of
noncombustible material if they
project into the 3' setback area
from the property line. Section
1711.
Plastic skylights shall not be
installed within that portion of a
roof located within a distance to
property line where openings in
exterior walls are prohibited or
required to be protected. Section
5207 (a) 7.
Show locations of permanently wired
smoke detectors with battery backup:
ALL 3 /sr
a J Inside each bedroom.'"" pt/e &£OtiOG
Centrally located in corridor or
area giving access to sleeping
, rooms.
c. On each story.
$. In the basement, if part of the
dwelling unit.
e7. When sleeping rooms are upstairs,
at the upper level in close
proximity to the stair.
In rooms adjacent to hallways
serving bedrooms, when such rooms
have a ceiling height 24 inches
or more above the ceiling height
in the hallway.
NOTE: Detectors shall sound an alarm
audible in all sleeping areas of the
unit. Section 1210
When the valuation of a room
addition or repair exceeds $1,000,
or when sleeping rooms are created,
smoke detectors shall be provided
per item 19 above, except that smoke
detectors added at existing
construction need only be battery
powered. Section 1210.
GENERAL RESIDENTIAL REQUIREMENTS
Habitable rooms, other than
kitchens, shall contain at least 70
square feet of floor area. At least
one room shall have not less than
120 square feet of floor area.
Section 1207 (b).
"22. No habitable room, other than a
kitchen, shall be less than 7'0" in
any dimension. Section 1207 (c) .
Sleeping rooms shall have a window
or exterior door for emergency exit.
Sill height shall not exceed 44"
above the floor. The window must
have an openable area of at least
5.7 square feet with the minimum
openable width 20" and the minimum
openable height 24". Section 1204.
Basements in dwelling units shall
comly with the above (even if riot
designated as sleeping rooms).
Section 1204.
11/16/93
An occupancy separation is not
required between carport and
residence, provided the carport is
open on two or more sides and has no
enclosed uses above. Section 503
(a) Exception 3.
Show garage framing sections, size
of header over garage opening,
lateral cross bracing at plate line,
method bracing garage front and
holddowns if required. Chapter 23.
NOTE: Maximum shear panel height-to-
width ratio is 3-1/2 to 1 for
plywood. Table 25-1.
Doors may open into the garage only
if the floor or landing in the
garage is not more than one inch
lower than the door threshold.
Section 3304 (i) .
Provide an 18" raised platform for
any FAU, water heater, or other
device in the garage which may
generate a flame or spark. UMC
Section 508, UPC Section 1310 (a).
FOUNDATION REQUIREMENTS
Per soils report, note on the plan
the soils classification, whether or
not the soil is expansive and note
86COUJ t'"'e allowable bearing value.
Section 2905 (c).
7/. The foundation plan does not comply
with the soils report
recommendations for this project.
Please review the report and modify
design, notes and details as
• required to show compliance:
77.
'/•The soils engineer recommended that
he/she review the foundation
excavations. Note on the foundation
plan that "Prior to the contractor
requesting a Building Department
foundation inspection, the soils
engineer shall advise the building
official in writing that:
1. The building pad was prepared in
accordance with the soils report,
¥•
s/.
2. The utility trenches have been
properly backfilled and
compacted, and
3. The foundation excavations, the
soils expansive characteristics
and bearing capacity conform to
the soils report."
Provide a letter from the soils
engineer confirming that the
foundation plan, grading plan and
specifications have been reviewed
and that it has been determined that
the recommendations in the soils
report are properly incorporated
into the construction documents
(when required by the soil report).
Show height of all foundation walls.
Chapter 23.
Show height of retained earth on all
foundation walls. Chapter 23.
If cut or fill slopes exist, show
distance from foundation to edge of
cut or fill slopes and show
steepness and heights of cuts and
fills. Chapter 29.
Note on plans that wood shall be 6"
minimum above finish grade. Section
2907 (a).
Note on plans that surface water
will drain away from building and
show drainage pattern a«4—feey
Section 2905 (f).
Dimension foundation
Table 29A:
per U.B.C.
Floors Footing
Supported* Stemval1 Width Depth piickness
6"
8"
10"
12" 12"
15" 18"
18" Zk"
6"
T>
8"
•Foundations may support a roof in
addition to the floors. Where only a
roof is supported, use foundation for one
floor.
Show foundation sills to be pressure
treated, or equal. Section 2516 (c)
3.
IS A-JO/l. £f/»o/e.r. Oi^ iF
APT
copy /ve.QJOL7-/e.f/»o/er
11/17/93
s/.Show foundation bolt size
spacing. Section 2907 (f).
and
3.
¥•
Specify size, I.C.B.O. number and
manufacturer of power driven pins
and expansion anchors. Show edge
and end distances and spacing.
Section 302 (d) .
If required, show size, embedment
and looJt'ioTT'of hold down anchors on
foundation clan. Section 302 (d) .
If hold downs are required, note on
plan that hold down anchors must be
tied in place prior to foundation
inspection. Section 305 (e) 1.
Show adequate footings under all
bearing walls and shear walls.
Section 2907 (b) .
Show on the plans details for
stepped footings steeper than 1:10.
Section 2907 (c) .
Show minimum 18" clearance from
grade to bottom of floor joists and
minimum 12" clearance to bottom of
girders. Section 2516 (c) 2.
Show pier size, spacing and depth
into undisturbed soil. Table 29-A.
Show minimum underfloor access of
18" x 24". Section 2516 (c)2.
Show minimum underfloor ventilation
equal to 1 sq. ft. for each 150 sq.
ft. of underfloor area. Openings
shall be as close to corners as
practical and shall provide cross
ventilation on at least two
approximately opposite sides.
Section 2516 (c) 6.
FRAMING
Show wall bracing. Every exterior
wood stud wall and main cross-stud
partition shall be braced at each
end at least every 25 feet of length
with 1x4 diagonal let-in braces or
equivalent. Section 2517 (g) 3,
Table 25-V.
3SS. In 2-story buildings, shear panels
' at the first story (at least 48
inches in width) shall be located at
each end or as near thereto as
possible and comprise at least 25
percent of the linear length of the
wall, or provide design. Section
2517(g)3, Table 25-V.
11/6. Note cross bridging or blocking.
' Floor joists and rafters 12" or
more in depth shall be supported
laterally by bridging at intervals
not exceeding 8 feet, unless both
edges are held inline. Sec. 2506
(h) .
10d
r
. Show blocking at ends and at
supports of floor joists, rafters
and trusses at exterior walls.
Section 2517 (d) 3, 2517 (h) 7.
102. Bearing partitions, perpendicular
' to joists, shall not be offset from
supporting girders, beams, walls or
partitions, more than the depth of
the joist. Section 2517 (d) 5.
10/3.
f
Show rafter ties. Rafter ties
shall be spaced not more than 4
feet on center and be just above
the ceiling joists, where rafters
and ceiling joists are not
parallel. Section 2517 (h) 5.
10/4. Show rafter purlin braces to be not
less than 45 degrees to the
horizontal. Section 2517 (h) 6.
1 Gf 5. Show double top plate with minimum
' 48" lap splice. Section 2517 (g)
2.
106- Show nailing will be in compliance
' with Table 25-Q.
[IOTA Show or note fire stops at the
—-^ following locations per Section
2516 (f):
a. In concealed spaces of stud
walls and partitions, including
furred spaces, at the ceiling
and floor levels and at 10 foot
intervals both vertical and
horizontal;
11/17/93
b. At all interconnections between
concealed vertical and
horizontal spaces such as occur
at soffits, drop ceilings and
cove ceilings;
c. In concealed spaces between
stair stringers at the top and
bottom of the run and between
studs along and inline with the
run of stairs if the walls
under the stairs are
unfinished;
d. In openings around vents,
pipes, ducts, chimneys,
fireplaces and similar openings
which afford a passage for fire
at ceiling and floor levels,
with noncombustible materials.
e. At openings between attic
spaces and chimney chases for
factory-built chimneys.
In duplexes, draft stops shall be
provided in floor-cei1 ing
assemblies and attics in line with
walls separating units and
separating units from common areas.
Section 2516(f)4.
Show stud size and spacing.
Maximum allowable stud heights:
Bearing wall: 2 x4 and 2x6 max.
10'; Non-bearing: 2x4 max. 14' , 2
x 6 max. 20'. Table 25-R-3.
Studs supporting two floors, a roof
and ceiling must be 3 x 4 or 2 x 6
at 16" o.c. Table 25-R-3.
Note on the plans that an A.I.T.C.
Certificate of Compliance for glued
laminated wood members shall be
given to the building inspector
prior to installation. Section
2505.
Detail all post-to-beam and post-
to-footing connections and
reference the detail to the plan.
Section 2516 (m).
113.) Detail shear transfer connections,
including roof and floor
diaphragms, to shear walls.
Section 2513.se n.
IpS.
Specify nail size and spacing for
all shear walls, floor and roof
Indicate required
Maintain maximum
dimension ratios.
J, K and Section 4714
diaphragms.
blocking.
diaphragm
[Tables 25 I,
(d)].
Provide truss details and truss
calculations for this project.
Specify truss identification
numbers on the plans.
Show clearance between top plate of
interior partitions and bottom
chord of trusses. (To ensure non-
bearing condition between supports
as designed).
Provide roof framing plan and floor
framing plan. Section 302 (d).
Provide framing sections through
Section 302 (d) .
Specify all header sizes for
openings over 4' wide. Section
2517 (g) 5.
Provide calculations for main
vertical and horizontal framing
members and footings. Section 302
(b) .
Provide calculations for lateral
loads, shear panels, shear transfer
and related. Section 302 (b).
122. In Seismic Zones 3 and 4, the
' allowable shear wall values for
drywall in Table 47-1 must be
reduced 50 percent when considering
earthquake loads. This does not
apply to wind loads. Footnote 1.
Show on the plans all structural
requirements developed in the
structural calculations. Section
302 (d). (See comments below or at
end.)
/.$ TAAJ Ce TH-e
OF o/C
11/17/93
176
Columns and posts located on
concrete or masonry floors or decks
exposed to the weather or to water
splash or in basements and which
support permanent structures shall
be supported by concrete piers or
metal pedestals projecting 1"
minimum above floors unless
approved wood of natural resistance
to decay or treated wood is used.
Section 2516 (c) 4.
Individual concrete or masonry
piers shall project at least 8
inches above exposed ground unless
the columns or posts which they
support are of approved wood of
natural resistance to decay or
treated wood is used.
Section 2516 (c) 4.
Show location of attic access with
a minimum size of 22"x30", unless
the maximum vertical headroom
height in the attic is less than
30". Access must be provided to
each separated attic area, shall be
located in a hallway or other
readily accessible location and 30"
headroom clearance is required
above the opening. Section
3205(a).
Detail truss layout for 30" x 30"
attic access, if required for
equipment in the attic and detail
30" x 30" clearance through truss
webs.
Specify plywood and/or particle
board thickness, grade and panel
span rating. Table 25-S.
When roof pitch is less than 3:12,
design ridge as a beam. Section
2517 (h).
Ridges, hips, and valleys shall be
at least one size larger than
supported rafters. Section 2517
(h) 3.
In open beam construction, provide
strap ties across the beams at the
ridge support. Section 2501 (b).
13/2. If foundation cripple wall studs
are less than 14" high, framing
shall be solid blocking, or
sheathed with plywood. Section
2517 (g) 4.
lj?3. Cripple wall studs exceeding 4 feet
in height shall be 3 inch by 4 inch
or 2 inches by 6 inches when
supporting 2 stories. Section 2517
(g) 4.
Note on the plans that "all
weather-exposed surfaces shall have
.a weather-resistive barrier to
protect the interior wall covering
and that exterior openings shall be
flashed in such a manner as to make
them weatherproof". Section 1708.
MECHANICAL (UNIFORM MECHANICAL CODE)
All heating, ventilating, and cooling
systems and appliances shall comply with
the Uniform Mechanical Code.
13/5. Show the size, location and type of
' all heating and cooling appliances
or systems.
L3/6. Every dwelling unit shall be
provided with heating facilities
capable of maintaining a room
temperature of 70 degrees F. at 3
feet above the floor in all
habitable rooms. Show basis for
compliance. UBC, Sec. 1212.
Note on the plans that the FAU
closet or alcove must be 12 inches
wider than the furnace or furnaces
being installed. UMC Section 704.
1/8. Show minimum 30" deep unobstructed
working space in front of furnace.
Section 505, UMC.
Furnace shall not be installed in
any bedroom, bathroom or in a
closet or confined space with
access only through such room
unless specified as direct vent
appliance, enclosed furnace or
electric heating appliance. Section
704, UMC.
U6. Show source of combustion air to
furnace, per Chapter 6, UMC.
14
11/17/93 10
Show on the plan that ground-fault
circuit-interrupter protection
complies with 1990 NEC Art. 210-8,
which reads as follows:
All 125-volt, single-phase, 15- and
20- ampere receptacles installed in
bat-brooms, garages, basements,
outdoors—aad within 6—feet—of a
sink.
PLUMBING (UNIFORM PLUMBING CODE)
1S4. Show water heater size, type and
' location on plans. UPC, Section
1301.
15/5. Note on the plans that "combustion
air for fuel burning water heaters
will be provided in accordance with
the Uniform Plumbing Code".
Fuel combustion water heater shall
not be installed in clothes
closets, in a bathroom or bedroom,
or in a closet opening into
bathroom or bedroom. UPC, Section
1309.
Provide adequate barrier to protect
water heater from vehicle damage.
An 18" platform for the water
heater does not satisfy this
requirement. UPC, Section 1310.
Show T and P valve on water heater
and show route of discharge line to
exterior. UPC, Section 1007 (e).
15
i&A,
Show that water heater is
adequately braced to resist seismic
forces. UPC, Section 1310.
Show shower stall can accommodate a
30" circle and has a minimum floor
area of 1,024 sq. in. UPC 909 (d).
New water closets and associated
flushometer valves, if any, shall
use no more than 1.6 gallons per
flush and shall meet performance
standards established by the
American National Standards
Institute Standard A112.19.2, and
urinals and associated flushometer
valves, if any, shall use no more
than one gallon per flush and shall
meet performance standards
established by the American
162:.
/
National Standards Institute
Standard A112.19.2. H & S Code,
Section 17921.3 (b) .
NOISE INSULATION (DUPLEXES)
Show details of duplex common
(party) walls and floor/ceiling
assemblies to achieve a Sound
Transmission Class (STC) rating in
walls of 50 decibels and an Impact
Insulation Class (IIC) rating on
floor/ceiling of 50 decibels.
Title 24.
Show how penetrations of assemblies
for piping, electrical devices,
recessed cabinets, bathtubs,
soffits, or heating ventilating, or
exhaust ducts shall be sealed,
lined, or insulated to maintain
required sound transmission rating.
Title 24.
Provide insulation in walls and
ceiling to achieve STC of 50
between garage and living area if
garage use is not controlled by
resident. Title 24.
ENERGY CONSERVATION
NOTE: Plans submitted after January 1,
1993 must comply with the new energy
standards .
Provide plans, calculations and
worksheets to show compliance with
current energy standards.
COMPLY i^>TH /7O
The regulations require a properly
completed and properly signed Form
CF-1R to be either imprinted on the
plans, taped to the plans or
"sticky backed" on the plans, to
allow the building inspector to
readily compare the actual
construction with the requirements
of the approved energy design.
All energy items shown on the plans
must be in agreement with the
information shown on the properly
completed Form CF-1R.
11/17/93 12
168]Specify on the building plans all
of the mandatory energy
conservation requirements as
listed on the enclosure titled,
"Mandatory Measures Checklist."
Show the make, model and
efficiency of the space heating
(or cooling) system.
For room additions, show
compliance with the energy
standards. See attached.
Provide fluorescent general
lighting (40 lumens per watt) in
kitchen(s) and bathrooms.
Provide a note on the plans
stating "All new glazing
(fenestrations) will be installed
with a certifying label attached,
showing the U-value."
CARLSBAD S.F.D. & DUPLEX SUPPLEMENT
Energy conservation design should
be for Zone 7.
For gas piping under slabs that
serve kitchen island cooktops, see
the attached Policy 91-46 for
special sleeve and clean-out
requirements.
New residential units must be pre-
plumbed for future solar water
heating. Note that two roof jacks
must be installed where the water
heater is in the one story garage
and directly below the most south
facing roof (City Ordinance No.
8093).
Note that two 3/4" copper pipes
must be installed to the most
convenient future solar panel
location when the water heater is
not in a one story garage and is
not directly below the most south
facing roof. (City Ordinance No.
8093) .
All piping for present or future
solar water heating must be
insulated when in areas that are
not heated or cooled by mechanical
means (city policy).
Incorporate the waterproofing
details, on the attached Policy
80-8, where interior living space
occurs below grade at the masonry
wall(s) .
Show on the Title Sheet on the
plans, the information required by
the attached - Developmental
Services Sheet 112383.
aew—rcoidcntial—buildings,
additii-OTTS-; ryqniie—a
-Pl oao G— oubmi't—fewo
•s—IHrrrrrt-et}—LLT-UHK—s Cory
q ff *n ?T-°-a-) fc^oja—=>
soils—~jsep»e-fc-—is——e»fc—*e€{a*i?e«K
Esgil Corporation will advise the
City to place their soils notice
stamp on the plans.
All structures require a Class B
roof covering, except room
additions. If a room addition
covers all of the existing
building (2nd story addition),
then the above exception doesn't
apply.
City Ordinance 9792 requires two
parking spaces/unit with clear
area of 20'x20' i.e. no washing
machines, etc. Show compliance.
Overflow roof drains shall
terminate in an area where they
will be readily visible and will
not cause damage to the building.
If the roof drain terminates
through a wall, the overflow drain
shall terminate 12" minimum above
the roof drain. Policy 84-35.
MISCELLANEOUS
Please see additional corrections,
or remarks, on the following page.
To speed up the recheck process,
note on this list (or a copy)
where each correction item has
been addressed, i.e., plan sheet,
note or detail number, calculation
page, etc.
Please indicate here if any
changes have been made to the
plans that are not a result of
corrections from this list. If
there are other changes, please
briefly describe them and where
they are located in the plans.
Have changes been made to the
plans not resulting from this
correction list? Please indicate:
Yes No
11/30/93 13
The City of Carlsbad has contracted with
Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego,
California 92123; telephone number of
619/560-1468, to perform the plan check
for your project. If you have any
questions regarding these plan check
items, please contact
_ PETE r?sc
at Esgil Corporation.
Thank you .
TO
DC)(J0L£_ TOP
A
0 f-
f=o£L
11/19/93 14
COMPONENT
INSULATION
Ceiling
Wall
Floor
ENERGY REQUIREMENTS FOR RESIDENTIAL ROOM ADDITIONS - CLIMATE ZONE 7
Floor Area
7 ^\
500-999 ft2<100 ft2
R-19
R-13
R-13
GLAZING (FENESTRATION)
U-Value1 0.75
% of added floor area <.50 sq. ft
0.75
.20% + Removed2
SHADING
THERMAL MASS
n/a
n/a
Note 4sSPACE HEATING
(no electric allowed)
If Gas, efficiency^
If Heat Pump:
Split System, efficiency^
Single Package System, eff.=
SPACE COOLING Note5
If Split System, eff.=
If Single Package, eff.=
78%AFUE5
WATER HEATING Note
0.75
20% + Removed2
6.8HSPF5
6.6HSPF5
10.0SEER5
9.7SEER5
Note6
>1000 ft2
R-30
R-13
R-19
0.75
20%
Req.'
78%AFUE5
6.5HSPF5
6.6HSPF5
lO.OSEER^
9.7SEER5
Note6
1. Please note that some metal-frame windows may not satisfy the U-value requirement of
0.75. For additions and alterations only, dual glazed "greenhouse" windows and
skylights may be assumed to meet this requirement.
2. 20% of added floor area plus the area of any glazing removed because of the addition.
3. A coefficient of.0.66 will be assumed to be provided when dual glazing is used.
4. If. the addition will be on top of existing construction, and:
(a)If the addition has conditioned area below all portions, then no thermal mass is
required.
(b) If the addition will be over non-conditioned area (partially or wholly) in a building
mostly of raised-floor construction (after the addition), then thermal mass is required
in the addition (equal to 5% of the area of the addition that is over non-conditioned
space). This may be provided by showing a 2" concrete slab at hearths, countertops,
etc.
(c)If the addition will be over non-conditioned area in a building mostly of slab-on-
grade construction (after the addition), then no thermal mass is required.
If the addition will be at the ground floor, and:
(a) If the addition will be in a building mostly of raised-floor construction (after the
addition) , then thermal mass is required in the addition (equal to 5% of the added
conditioned footprint area) . This may be provided by showing a 2" concrete slab at
hearths, countertops, etc.
(b)If the addition will be in a building mostly of slab-on-grade construction (after
the addition), then thermal mass is required in the addition (equal to 20% of the added
conditioned slab-on-grade floor area). This may be provided by covering a portion of
the slab-on-grade with tile, wood, etc.
5. If the existing system will be utilized (if no additional systems are needed to provide
UBC heating requirements), there are no special requirents, other than mandatory
insulation for any extended ducts, etc.
6. If the total number of water heaters increases in the residence, then calculations must
be submitted to show that the entire existing-plus-addition system meets the water
heating energy budget.
9-93 ER-RA7
Certificate of Compliance: Residential (Page 1 of 2)CF-1R
•
Project Title
Project Address
Documentation Author
Compliance Method (Package,
Telephone
Data
Building Permit *
Plan Check /Date
Field Check /Data
Point System or Computer) Cllm»te Zone Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area:
Building Type: _
(check one or more)
Front Orientation:
Number of Dwelling Units:
Floor Construction Type:
ft"
Single Family
Mutti- Family
Addition
Existing-Plus-Addition
North / East / South / West / All Orientations
(Input orientation in degrees and cJrde one.)
Slab / Raised Floor (circle one or both)
BUILDING SHELL INSULATION
Component Insulation
R-Value
Construction
Assembly
U-Value
Location/Comments
(anic, to garage, typical, etc.)
Wall
Wall
Roof
Roof
Floor
Floor
Slab Edge....
FENESTRAT10N
Fenestratbn Area
Orientation (sQ
Shading Devices
Front ( )
Front ( )
Lett ( )
Left. ( )
Rear ( )
Rear ( )
Right ( )
Right ( )
Skylight
Skylight
Fenestration
U-Va!ue
Interior
(roller blind, etc.)
Exterior
(shadescreen. etc.)
Overhang .. Framing Type'•
(yes/noj (metal/wood/Viriyl)
THERMAL MASS
Type/Covering Area Thickness
(slab/exposed, tile, etc.) (sf) (inches)Location/Description (kitchen, bath, etc.)
R»vl»*d January 19 J2
Certificate of Compliance: Residential (Page 2 of 2)CF-1R
Project Title Data
HVAC SYSTEMS
Note: Input hydronic or combined hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat
pump, etc.) (AFUE/HSPF) (duds/attic, etc.) R-Value Type
Cooling Equipment Minimum
Type (air conditioner. Efficiency
heat pump, evap. cooling) (SEER)
Duct
Location
(attic, etc.)
Duct
R-Value
Thermostat Configuration
Type (split or package)
WATER HEATING SYSTEMS
Water Heater Distribution
Type Type
Rated1
Number Input (kW
in System or Btu/hr)
Tank
Capacity
(gallons)
Energy
Factor or
Recovery Standby
Efficiency Loss (%)
External
Tank
Insulation
R-Value
1. For small gas storage (rated input £ 75.000 Btu/hr), electric resistance and heal pump water heaters, list Energy Factor.
For large gas storage water heaters (rated inputs 75.000 Btu/nr), list Rated Input, Recovery Efficiency and Standby Loss.
For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6, of
the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the
individual with overall design responsibility: Wh$n this certificale of compliance is submitted for a single building plan to be built in multiple
orientations, any shading feature that is varied is indicated in the Special Features/Remarks section.
Designer Or Owner (per Business & Professions Code)
Name:
Title/Finn:
Address:
Documentation Author
Telephone:
Lie.*:
Name:
Title/Firm:
Address:
Telephone:
(signature)
Enforcement Agency
(date)
Name:
Title:
Agency:
Telephone:
(signature)(date)
(signature/stamp)
R«vlt*d Janutry 1992
(date)
Mandatory Measures Checklist: Residential MF-1R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance
approach used. Items marked with an asterisk (") may be superseded by more stringent compliance requirements
listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features
noted shall be considered by all parties as binding minimum component performance specifications for Ihe
mandatory measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION DESIGNER ENFORCEMENT
Building Envelope Measures
• §150(a): Minimum R-19 ceiling insulation. •
§150(b): Loose fill insulation manufacturer's labeled R-Va!ue.
• §150{c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls).
• §150(d): Minimum R-13 raised floor insulation in framed floors; minimum R-8 in concrete raised floors.
§150(1): Slab edge insulation • water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/inch.
§118'. Insulation specified or installed meets California Energy Commission quality standards.
Indicate type and form.
§11S-17: Fenestration Products, Exterior Doors and Infiltration'Exfiltration Controls
a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
b. Manufactured fenestration products have label with certified U-vaiue, and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§150(g): Vapor barriers mandatory in Climate Zones 14 and 16 only.
§150(0: Special infiltration barrier installed to comply wi!h §151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory-built fireplaces have:
a. Closeable metal or glass door '
b. Outside air intake with damper and control
c. Rue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(i): Setback thermostat on all applicable heating systems.
§1500"): Pipe and Tank Insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater).
2. First 5 feet of pipes closest to water heater tank, non-rea'rculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in redrculafing sections of hot water system.
4. Cooling system piping below 55°F insulated.
5. Piping insulated between heating source and indirect hot water tank.
" §150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers
3. Gravity ventilating systems serving conditioned space have either automatic or readily accessible,
manually operated dampers..
§114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,
no electric resistance heating and no pilot light
2. System is installed with:
a. At least 36" pipe between filler and heater for future solar heating.
b. Cover for outdoor pools or outdoor spa.
3. Pool system has directional inlets and a circulation pump time switch.
§115: Gas-fired central furnace, pool heater, spa heater or household cooking appliance have no
continuously buring pilot light (Exception: Non-electrical cooking appliance with pilot < 150 Btu/hr.)
Lighting Measures
§150(k): 40 lumens/watt or greater for general lighting in kitchens and rooms with water dosets; and
recessed ceiling fixtures 1C (insulation cover) approved.
-tC' • •
Revised January 1992
Datei.
Prepared byi
Jurisdiction rART.SRAD
VALUATION AND PLAN CHECK FEE
Q Bldg. Dept,
D Esgil
PLAN CHECK NO.
BUILDING ADDRESS / 7 3 £ C.e^tUS CT
APPLICANT/CONTACT PHONE NO.
BUILDING OCCUPANCY K3 /f*\ DESIGNER PHONE
TYPE 0? CONSTRUCTION 3Z~/V
BUILDING PORTION
£3 A&D
Air Conditioning
Commercial
Residential
Res. or Comm.
Fire Snrinklers
Total Value
BUILDING AREA
l//icu£ P£^ ^'r'
—
CONTRACTOR PHONE
VALUATION
MULTIPLIER
r Arruowa*'
'@
§'
§ • •
i
VALUE
/£ 2"2-f
/^ ^Z9'
Building Permit Fee $
Plan Check Fee $
COMMENTS:
/SO
$ /?°°
SHEET / OF /12/87
City of Carlsbad
Engineering Department
DATE:
BUILDING AODR
PROJECT DESCRIPTION:
ASSESSOR'S PARCEL NUMBER:
BUILDING PLANCHECK CHECKLIST
Y PLANCHECK NO. CB
ESS: 1733 O
crrv>o<
CT.
5O5L -EST. VALUE /lo
APPROVAL
The item you have submitted for review has been
approved. The approval is based on plans, information
and/or specifications provided in your submittal; therefore
any changes to these items after this date, including field
modifications, must be reviewed by this office to insure
continued conformance with applicable codes. Please
review carefully all comments attached, as failure to
comply with instructions in this report can result in
suspension of permit to build.
ENGINEERING DEPARTMENT
DENIAL
Please see the attached report of deficiencies marked
with O Make necessary corrections to plans or
specifications for compliance with applicable codes and
standards. Submit corrected plans and/or specifications
to this office for review.
DA Right-of-Way permit is required prior to construction
of the following improvements:
By:.Date:
By:.Date:
By:.Date:
FOR OFFICIAL USE ONLY
!)N<3 AUTHOHIZAT10N TO ISSUE
ENGINEERING DEPT. CONTACT PERSON
I—I Dedication Application
LJ Dedication Checklist
I—I Improvement Application
I I Improvement Checklist
I—I Future Improvement Agreement
I—I Grading Permit Application
I I Grading Submittal Checklist
I I Right of Way Permit Application
LJ Right of Way Permit Submittal Checklist
and Information Sheet
I—I Sewer Fee Information Sheet
P:\DOCS\CHKLST\BP0001.FRM
NAME:
City of Carlsbad
ADDRESS: 2075 Las Palmas Dr.. Carlsbad. CA 92009
PHONE : (619)438-1161. Ext. •
A-4
REV 05/11/94
2O75 Las Palmas Dr. • Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-0894
BUILDING PLANCHECK CHECKLIST
SITE PLAN
Srdv'
0 D D 1 . Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow
B. Existing & Proposed Structures
C. Existing Street Improvements
2. Show on site plan:
A. Drainage Patterns
B. Existing & Proposed Slopes
D. Property Lines Easements
E. Easements
F. Right-of-Way Width & Adjacent Streets
C. Existing Topography
U Dr
ET D
LJ 3. Include note: "Surface water to be directed away from the building foundation at a 2%
gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)."
[Perl 985 UBC 2907(d)5].
On graded sites, the top of any exterior foundation shall extend above the elevation
of the street gutter at point of discharge or the inlet of an approved drainage device
a minimum of 12 inches plus two percent1 (per 1990 UBC 2907(d)5.).
D 4. Include on title sheet
A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commercial/industrial buildings and tenant improvement projects, include: Total
building square footage with the square footage for each different use, existing sewer
permits showing square footage of different uses (manufacturing, warehouse, office,
etc.) previously approved.
EXISTING PERMIT NUMBER DESCRIPTION
P:\DOCS\CHKLST\BP0001 .FRM Page 1 of 4 REV 05/11/94
V
/
2njtV 3rd/
BUILDING PLAN CHECK CHECKLIST
DISCRETIONARY APPROVAL COMPLIANCE
5. Project does not comply with the following Engineering Conditions of approval for
Project No. *
Conditions were complied with by: Date:
DEDICATION REQUIREMENTS
6. Dedication for all street Rights-of-Way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and for
remodels with a value at or exceeding $ -pursuant to Code Section
18.40.030.
Dedication required as follows:
Attached please find an application form and submittal checklist for the dedication
process. Provide the completed application form and the requirements on the
checklist at the time of resubmittal.
Dedication completed by ' Date:
IMPROVEMENT REQUIREMENTS
D D D 7a. All needed public improvements upon and adjacent to the building site must be
constructed at time of building construction whenever the value of the construction
exceeds $ -pursuant to Code Section 18.40.040.
Public improvements required as follows:
Please have a registered Civil Engineer prepare appropriate improvement plans and
submit them together with the requirements on the attached checklist for a separate
plancheck process through the Engineering Department. Improvement plans must be
approved, appropriate securities posted and fees paid prior to issuance of permit.
Attached please find an application form and submittal checklist for the public
improvements requirements. Provide the completed application form and the
requirements on the checklist at the time of resubmittal.
Improvement Plans signed by:' Date:
P:\DOCS\CHKLST\BP0001.FRM Page 2 Of 4 REV 05/11/94
]
V
1stv/ 2ndv/
D ~
BUILDING PLANCHECK CHECKLIST
7b. Construction of the public improvements may be deferred pursuant to code Section
18.40. Please submit a recent property title report or current grant deed on the
property and processing fee of $ so we may prepare the
necessary Future Improvement Agreement. This agreement must be signed, notarized
and approved by the City prior to issuance of a Building Permit.
Future public improvements required as follows:
Improvement Plans signed by:.Date:
D
7c. Enclosed please find your Future Improvement Agreement. Please return signed and
notarized Agreement to the Engineering Department.
Future Improvement Agreement completed by:
Date:
7d. No Public Improvements required. SPECIAL NOTE: Damaged or defective
improvements found adjacent to building site must be repaired to the satisfaction of
the City Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section 11.06.030
of the Municipal Code.
8a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
8b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be Submitted together with the completed application form attached.
NOTE: The Grading Permit must be issued and rough grading approval obtained prior
to issuance of a Building Permit.
Grading Inspector sign off by: • Date: '
8c. No Grading Permit required.
P:\DOCS\CHKLST\BP0001 .FRM Page 3 of 4 REV 05/11 /94
BUILDING PLANCHECK CHECKLIST
MISCELLANEOUS PERMITS
D |)P//|P 9. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or
private work adjacent to the public Right-of-Way. Types of work include, but are not
limited to: street improvements, trees, driveways, tieing into public storm drain, sewer
, and water utilities.
Right-of-Way permit required for ;
A separate Right-of-Way permit issued by the Engineering Department is required for
the following: \
10. A SEWER PERMIT is required concurrent with the building permit issuance. The fee
is noted in the fees section on the following page.
11. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial
Waste Permit Application Form and submit for City approval prior to issuance of a
Permit. ^
Industrial waste permit accepted by: Date:
P:\DOCS\CHKLST\BP0001.FRM Page 4 Of 4 REV 05/11/94
ENGINEERING DEPARTMENT ENGINEERING REVIEW SECTION
FEE CALCULATION WORKSHEET
D Estimate based on unconfirmed information from applicant.
D Calculation based on building plancheck plan submittal.
Address:Bldg. Permit No..
Prepared by:_Date:Checked by:_Date:
EDU CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq. Ft.: 'EDU's:
Total EDU's:
APT CALCULATIONS: List types and square footages for all uses.
Types of Use: Sq. Ft.: ADTs:_
Total ADTs:
FEES REQUIRED:
PUBLIC FACILITIES FEE REQUIRED D YES D NO (See Building Department for amount)
WITHIN CFD: D YES (no bridge & thoroughfare fee, D NO
reduced Traffic Impact Fee)
D 1.PARK-IN-LIEU FEE
FEE/UNIT:
2.TRAFFIC IMPACT FEE
ADTs:
3. BRIDGE AND THOROI
ADTs:
PARK AREA:
X NO.O. IflNITS:
FEE ADT:
:IF#RE FEE
X FEE^ADT:
D 4. FACILITIES MANAGEMENT FEE ZOr>
SQ.FT.: X FEE
D 5. SEWER FEE
=$_
=$_
=$_
SQ.FT.:
PERMIT No.
EDU's:FEE/EDU:
BENEFIT AREA:
EDU's:
DRAINAGE BASIN:.
X FEE/EDU:
=$_
=$_
=$_
U 6. SEWER LATERAL ($2,500 DEPOSIT)
D 7. WATER FEE
EDU's: . X FEE/EDU:
=$_
=$
TOTAL OF ABOVE FEES*: $
*NOTE: This calculation sheet Is NOT a complete list of all fees which mav be due.
P:\DOCS\MISFORMS\BP0002.FRM REV 04/12/94
PLANNING CHECKLIST
Plan Check No.9»- ~73/ Address /?3^L C£feJ3Qi£
Planner VAN LYNCH Phone 438-1161 ext. 4325
(K
(Name)
APN:
Type of Project and Use
Zone /^'"A ^^Facilities Management Zone
CFD(in/^5) #
"Efr*
«l Vw +*a aa a
Legend
U U
i i
a. &
IU
i D
____
(It property in, complete SPECIAL TAX CALCULATION
WORKSHEET provided by Building Department.)
Item Complete
Item Incomplete - Needs your action
1, 2, 3 Number in circle indicates plancheck number where deficiency was
identified
Environmental Review Required: YES NOP£_ TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
D D Discretionary Action Required: YES NO X. TYPE
APPROVAL/RESO. NO.
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
California Coastal Commission Permit Required: YES /A NO
DATE OF APPROVAL:
San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725
(619) 521-8036
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval
D D Inclusionary Housing Fee required: YES NO
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
n
n
CM
nn
Site Plan:
Zoning:
2.
3.
4.
Provide a fully dimensioned site plan drawn to scale. Show: North
arrow, property lines, easements, existing and proposed structures,
streets, existing street improvements, right-of-way width, dimensioned
setbacks and existing topographical lines.
Provide legal description of property, and assessor's parcel number.
1. Setbacks:
Front:
Int. Side:
Street Side:
Rear:
Lot coverage:
Height:
Parking:
Required
Required
Required
Required
Required
Required
Spaces Required
Guest Spaces Required
'2Or Shown
JTf' Shown
shown
Shown
Shown
Shown If
^— Shown
Shown
D Additional Comments <<tisc>•*/
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER // Lj/ntrJl/DATE
PLNCK.FRM
STATE OF CALIFORNIA—THE RESOURCES AGENCY PETE WILSON, Governor
CALIFORNIA COASTAL COMMISSION
SAN DIEGO COAST AREA
3111 CAMINO DEL RIO NORTH, SUITE 200
- EXEMPTION LETTER
DATE: —T—
v AWNAME:
LOCATION:
PROJECT:
This is to certify that this location and/or proposed project has been
reviewed by the staff of the Coastal Commission. A coastal development permit
is not necessary for the reasons checked below.
The site is not located within the coastal zone as established by the
California Coastal Act of 1976, as amended.
The proposed development is included in Categorical Exclusion No.
adopted by the California Coastal Commission.
The proposed development is judged to be repair or maintenance activity
not resulting in an addition to or enlargement or expansion of the object
such activities (Section 30610(d) of Coastal Act).
The proposed development is an improvement to an existing single family
residence (Section 30610(c) of the Coastal Act) and not located in the
area between the sea and the first public road or within 300 feet of the
inland extent of any beach (whichever is greater) (Section 13250(b)(4) of
14 Cal. Admin. Code.
The proposed development is an improvement to an existing single family
residence and is located in the area between the sea and the first public
road or within 300 feet of the inland extent of any beach (whichever is
greater) but is not a) an increase of 10% or more of internal floor area,
b) an increase in height over 10%, or c) a significant non-attached
structure (Sections 30610(a) of Coastal Act and Section 13250(b)(4) of
Administrative Regulations). .
(OVER)
Page 2
The proposed development is an interior modification to an existing, use
with no change in the density or intensity of use (Section 30106 of
Coastal Act). --
The proposed development involves the installation, testing and placement
in service of a necessary utility connection between an existing, service
facility and development approved in accordance with coastal development-
permit requirements, pursuant to Coastal Act Section 30610(f).
\ ; ..
The proposed development is an improvement to a structure other than a
single family residence or .public',works .facility and is-^not subject to a
permit requirement (Section 13253 of Administrative Regulations).
The proposed'development is the rebuilding of a structure, other than a
public works facility, destroyed by natural disaster. The replacement
conforms to all of the requirements of Coastal Act:Section 30510(g).
"••*."' * ' • . *i.' - •*'"••*
Other: '
Please be advised that only the project described above is exempt from the
permit requirements of the Coastal Act. Any change in the project may cause
it to lose its exempt status. This certification is based on information
provided by the recipient of this letter. If, at a later date, this
information is found to be incorrect or incomplete, this letter will become
invalid, and any development occurring at that time must cease until a coastal
development permit is obtained.
Truly yours,
By:
Title:
6630A
^Certificate of Compliance: Residential (Page 1 of 2)CF-1R
Project Tltla
Project Address
Documentation Author Telephone
Compliance Method (Package, Point System or Computer)Cllmats Zona
Dale
Building Permit *
Plan Check / Dale
Field Check / Dale
Enforcement Agency Use Only
GENERAL INFORMATION
Total Conditioned Floor Area:
Building Type:
(check one or more)
Front Orientation:
Number of Dwelling Units:
Floor Construction Type:
Single Family
Mufti-Family
X Addition
Existing-Plus-Addilion
North / East / South / West / All Orientations
(Input orientation in degrees and cirde one.)
SlabJ/ Raised Floor (circle one or both)
BUILDING SHELL INSULATION
Component
Type
Insulation
R-Value
Construction
Assembly
U-Value
Location/Comments
(attic, to garage, typical, etc.)
Wall
Walt
Roof
Roof
Floor '..
Floor
Slab Edge....
FENESTRATION
Fenestratfon Area
Orientation (sf)
Shading Devices
Fenestration Interior Exterior Overhang .. Framing Type'••
U-Value (roller blind, etc.) (shadescreen, etc.) (yes/no) (rnetalAvood/viriyl)
Front ( )
Front ( )
Left ( )
Lett". ( )
Rear (V)
Rear ( )
Right ( )
Right ( )
Skylight
Skylight
THERMAL MASS
Type/Covering
(slab/exposed, tile, etc.)
Area Thickness
(sf) (inches) Location/Description (k'rtchsn. bath, etc.)
R*vl»>d January 1892
Certificate of Compliance: Residential (Page 2 of 2)CF-1R
Project Tllla Data
HVAC SYSTEMS
Note: Input hydronic of combined hydronic data under Water Heating Systems, except Design Heating Load.
Distribution
Heating Equipment Minimum Type and Duct or
Type (furnace, heat Efficiency Location Piping Thermostat
pump, etc.) (AFUE/HSPF) (ducts/anic, etc.) R-Value Type
^M£>77/(/<2
Cooling Equipment Minimum
Type (air condrtioner. Efficiency
heat pump", evap. coolina) (SEER)
Duct
Location
(attic, etc.)
Duct
R-Value
Thermostat
Type
Configuration
(split or package)
M/A
WATER HEATING SYSTEMS
Water Heater Distribution
Type Type
^/^77X/^
Rated1
Number Input (kW
in System or Btu/hr)
Tank
Capacity
(oal!ons)
Energy1
Factor or
Recovery
Efficiency
External
Tank
Standby Insulation
Loss (%) R-Value
1. For small gas storage (rated input S 75.000 Btu/hr). electric resistance and heat pump water heaters, list Energy Factor.'
For large gas storage water heater* (rated input £ 75.000 Btu/hr). list Rated Input, Recovery Efficiency and Standby Loss.
For Instantaneous gas water heaters, list Rated Input and Recovery Efficiency.
SPECIAL FEATURES/REMARKS (Add extra sheets if necessary)
COMPLIANCE STATEMENT
This certificate of compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6. of
the California Code of Regulations, and the administrative regulations to implement them. This certificate has been signed by the
individual with overall design responsibility: Whqh this certificate of compliance is submitted for a single building plan to be built in multiple
orientations, any shading feature that is varied is indicated in the Special Features/Remarks section.
Designer or Owner (p*r Business & professions code)
Name:
Address:
^ignature)
Enforcement Agency
(date)
Name:
Titfe: '
Agency:
Telephone:
Documentation Author
f
Name:
Title/Firm:
Address:
Telephone:
(signature)(date)
(signatureystamp)
R«vli»d Januiry 1992
(date)
Mandatory Measures Checklist: Residential MF-1R
NOTE: Lowrise residential buildings subject to the Standards must contain these measures regardless of the compliance
approach used. Items marked with an asterisk (') may be superseded by more stringent compliance requirements
listed on the Certificate of Compliance. When this checklist is incorporated into the permit documents, the features
noted shall be considered by all parties as binding minimum component performance specifications for the
mandatory measures whether they are shown elsewhere in the documents or on this checklist only.
DESCRIPTION DESIGNER ENFORCEMENT
Building Envelope Measures
* §150(a): Minimum RW ceiling insulation. •
§150(b): Loose fill insulation manufacturer's labeled R-Va!ua.
* § 150(c): Minimum R-13 wall insulation in framed walls (does not apply to exterior mass walls).
* §150(d): Minimum R-13 raised floor insulation in framed Roots; minimum R-8 in concrete raised floors.
§150(1): Slab edge insulation • water absorption rate no greater than 0.3%, water vapor transmission rate no
greater than 2.0 perm/Inch.
§ 118: Insulation specified or installed meets California Energy Commission quality standards.
Indicate type and form.
§11S-17: Fenestration Products, Exterior Doors and Infiltration'ExSltration Controls
. a. Doors and windows between conditioned and unconditioned spaces designed to limit air leakage.
b. Manufactured fenestration products have label with certified U-vaiue, and infiltration certification.
c. Exterior doors and windows weatherstripped; all joints and penetrations caulked and sealed.
§ \ 50(g): Vapor barriers mandatory in Climate Zones 14 and 15 only.
§150(1): Special infiltration ba/rier installed to comply with §151 meets Commission quality standards.
§150(e): Installation of Fireplaces, Decorative Gas Appliances and Gas Logs
1. Masonry and factory-built fireplaces have:
a. Clcseable metal or glass door
b. Outside air intake with damper and control
c. Flue damper and control
2. No continuous burning gas pilots allowed.
Space Conditioning, Water Heating and Plumbing System Measures
§110-13: HVAC equipment, water heaters, showerheads and faucets certified by the Commission.
§150(f): Setback thermostat on all applicable heating systems.
§150(j): Pipe and Tank Insulation
1. Indirect hot water tanks (e.g., unfired storage tanks or backup solar hot water tanks) have insulation
blanket (R-12 or greater) or combined interior/exterior insulation (R-16 or greater).
2. First 5 feet of pipes closest to water heater tank, non-redrculating systems, insulated (R-4 or greater).
3. All buried or exposed piping insulated in recirculating sections of hot water system.
4. Cooling syslem piping below SS^F insulated.
5. Piping insulated between heating source and indirect hot water tank.
•§150(m): Ducts and Fans
1. Ducts constructed, installed and sealed to comply with UMC Sections 1002 and 1004; ducts insulated
to a minimum installed value of R-4.2 or ducts enclosed entirely within conditioned space.
2. Exhaust fan systems have backdraft or automatic dampers
3. Gravity ventilating systems serving conditioned space have eilher automatic or readily accessible,
manually operated dampers..
§114: Pool and Spa Heating Systems and Equipment
1. System is certified with 78% thermal efficiency, on-off switch, weatherproof operating instructions,
no electric resistance heating and no pilot light.
2. System is installed with:
a. At least 36" pips between filler and heater for future solar heating.
b. Cover for outdoor pods or outdoor spa.
3. Pool system has directional inlets and a circulation pump time switch.
§U5: Gas-fited central furnace, pool heater, spa heater or household cooking appliance have no
continuously buring pilot light (Exception: Non-electrical cooking appliance with pilot < 150 Btu/hr.)
Lighting Measures
§150(k): 40 lumensAvatt or greater for general lighting in kitchens and rooms with water dcsets; and
recessed ceiling fixtures 1C (insulation cover) approved.
«C
Revised January 1992
J//A
<^Wr