Loading...
HomeMy WebLinkAbout1734 BONITA LN; ; CB900466; PermitBUILDING PERMIT Permit No: CB900466 05/18/90 10: 41 Project No: A9000566 Page 1 of 1 Development No: Permit Type: RESIDENTAL ADDITION/ALTERATION Parcel No: 205-080-14-00 Valuation: 21,556 Occupancy Group: Class Code: Status: ISSUED Description: RES ADD 317 Applied : 03/21/90 Apr/Issue : 05/18/90 Validated By: JPY Ste: *- I Job Address: 1734 BONITA LN Str : F1: 5 ,'Zy 'T . : :2 ..? - i -. Construction Type: NEW CWW? OWNER : DENTINO, WILLIAM Lic. 720-7810 1734 BONITA LN CARLSBAD,CA *** *** Fees Required *A* *** cted & Credits -_----------------_--------- Fees : 410.00 Adjustments: .ou .oo Total Fees: 410 e 00 146.00 264.00 Fee description Ext fee Data __------------------------------------------------- Building Permit 225.00 Plan Check 146.00 * BUILDING TOTAL 373.00 Other > 10.00 REMODEL k ELECTRICAL TOTAL ($10 Minimum) 15.00 Enter 'Y' for Mechanical Issue Fee> 15.00 Y Each Hood/Fireplace > 6.50 Strong Motion Fee 2.00 Enter "Y" for Electric Issue Fee > 5.00 Y * MECHANICAL TOTAL 22.00 CrrY OF CARISBAD 2075 Las Palmas Dr., Carlsbad CA 92009 (619) 438-1161 - -- :ERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad, CA 92009 (1x9) 438-1161 1. PERMIT TYPE A - OCOMMERCIAL NEW OTENANT IMPROVEMENT B - 0 INDUSTRIAL ONEU UTENANT IMPROVEMENT C - ORESIDENTIAL UAPARTMENT UCONDO OSINGLE FAMILY DWELLING ~ADDITION/ALTERATION /*I I' 0 DUPLEX 0 DEMOLITION 0 RELOCAT ION OMOBI LE HOME 0 ELECTRICAL 0 PLUMBING r'- rgh? FOR OFFICF USF ON1 Y UMECHANICAL OPOOL OSPA nRETAlNlNG WALL OSOLAR 2. ~ROJECT INFORMATION PLAN CHECK No. LEGAL DESCRIPTIOW Lot NO. Subdivision Name/Number Unit NO. Phase No. CHECK BELOU IF SUBIIITTED: n2 Energy Calcs 02 Structural calcs 02 Soils Report,. 01 Addressed Envelope * PROPOSED USE 4 m7 r(4 EXISTING USE W Rps b, BLDG. SO. FTC. /7 # OF STORIES 3. CONTACT PERSON NAME ADDRESS CITY 5wr STATE ZIP COO€ DAY TELEPHONE SIGUATIIRF _._ - - CONTRACTOR 0 AGENT FOR CONTRACTOR OOWNER UAGENT FOR OWNER NAME ADDRESS CI JY STATE ZIP CODE DAY TELEPHONE OLESSEE OTENANT ADDRESS CITY ZIP COGE ?LoD E DAY TELEPHONE ADDRESS 6. CONTRACTOR NAME CITY STATE ZIP COOE DAY TELEPHONE STATE LIC. # LICENSE CLASS CITY BUSINESS LIC. # SIGNATURE TITLE DATE OESIGNER NAME ADDRESS CITY STATE ZIP CODE DAY TELEPHONE . STATE LIC. # 7. WORKERS' COMPENSATION Workers' Compensation Declaration: I hereby affirm that I have a certificate of consent to self-insure issued by the Director of Industrial Relations, or a certificate of Workers' Compensation Insurance by an ahitred insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY POLICY NO. EXPIRATION DATE Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE 8. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that I am exempt from the Contractor's License Law for the following reason: I as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon,, and uho does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however. the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044. Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). 0 I am exempt under Section (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, cmencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not mre than five hundred dollars [S5001). Business and Professions Code for this reason: SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUlLOlNG PERMITS ONLY: Is the awlicant or future building occupant required to submit a krsiness plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act7 Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? 0 YES NO OYES 0 NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site7 0 YES 0 NO IF ANY Of THE ANSUERS ARE YES. A FINAL CERTIFICATE OF OCCUPANCY MY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS )(ET OR IS MEETING THE REWIUEREYTS Of THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTIOW COllTROL DISTRICT. 9. CONSTRUCTION LENilING AGENCY I hereby affirm that there is a construction Lending agency for the performance of the work for which this permit is issued (Sec 3097Ci) Civil Code). LENDER'S NAME LENDER'S ADDRESS 10. APPLICANT'S SIGNATURE I certifv that I have read the application and state that the above information is correct. 1 agree to comply with ali City ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBMI AGAINST ALL LIABILITIES. JWJGMENTS, CMTS AND EXPENSES WHICH MY IN ANY WAY ACCRUE AGAINST SAID CITY IN COWSEOUENCE OF THE GRANTING OF THIS PERMIT. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not cmnced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is comnenced for a ueriod of 180 days (Section 3G3(d) Unifora Building Code). APPROVED BY: DATE: 1- -. I- , . I.' - W HITrFmELLOW: Applicant PI 04/ 19/ 9 1 INSPECTION HISTORY LISTING FOR PERMIT# CB900466 DATE INSPECTION TYPE INSP ACT COMMENTS 07/16/90 Interior Lath/Drywall RI RI Tl/MH/720-7180 07/16/90 Interior Lath/Drywall PD AP BY TONY MATA 05/02/90 Electric/Conduit/Wiring PD AP HIT <RETURN> TO CONTINUE.. . PERMIT# CB900466 DESCRIPTION: RES ADD TYPE: RAD JOB ADDRESS: 1734 APPLICANT: DENTINO, CONTRACTOR : OWNER: DENTINO, CITY OF CARLSBAD INSPECTION REQUEST FOR 07/16/90 317 BONITA WILLIAM WILLIAM REMARKS: Tl/MH/720-7180 SPECIAL INSTRUCT: WOULD TOTAL TIME: CD LVL DESCRIPTION LIKE 17 ST Interior Lath/Drywall LN TONY MATA TO INSPECTOR AREA PD PLANCK# CB900466 OCC GRP CONSTR. TYPE NEW STR: FL: STE : PHONE: 720-7810 PHONE : PHONE: 720-77&1 , INSPECTOR INSPECT IT ACT COMMENTS ' FOR ME ***** INSPECTION HISTORY ***** DATE DESCRIPTION 050290 Electric/Conduit/Wiring ACT INSP AP PD COMMENTS ESGIL CORPOFWTION 8320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92 123 (619) 56014438 DATE : A y / 9. /?Po JURISDICTION: LI7Y OF PARLsBt3;p PLAN CHECK NO: 9O-Vdb SET : PROJECT ADDRESS: /734 &Alf* LAP& PROJECT NAME: LMi.mL)n R trn4l?&L 4 &JJflf V- J 0 0 c3 El 0 0 0 FILE COPY OUPS DDESIGNER The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff - did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # REMARKS : By : 2 Enclosures: A)oI)d ESGIL CORPORATION ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92 123 (619) 5601468 DATE : A/DL 2~~993 JURISDICTION: 4.l7-Y OF PARLS&M nFILE COPY PLAN CHECK NO: 9Ll4bL SET: 7 UUPS Ti DESIGNER '4 PROJECT ADDRESS: J73 c/ hi T& LAM- 0 0 ci El !3 m The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies idenfified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: WLK tu3 133Y (B 0h)Kl) Lf~h)c (~AWBAO, PA ~JOOP Esgil staff did not advise the applicant contact person that plan check has been completed. 0 Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # u REMARKS: Enclosures: /G, cm. I13r ESGIL CORPORATION OGA UAA Ovw DM +/q- fa --_. ._.. .__..,. -. -., ._._.. .. - - .... .. . .... ~ . .. . - . . ... . . . .. . .. -. .-.. -- !: . ...e Citp of Carlsbab Datey-d&c 90 PROJECT ADDRESS: TO : kr M, oEL)TlJ.)?l 1739 &bdt TA LPIJF t73q AOl3lrn uR)e cAQL#&l.. tu 91oof PLAN CORRECTION SHEET / \ Plan Check NO. 9/c, d qb~,G Date plans received by the jurisdiction Date plans received by plan checker fY7-B Date,/& plan check completed 4/-;7LC%d - .A By g/m @).g& &JOR7-# .I FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. regulations enforced by the Building Inspection Department. based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. The plan check is based on You may have other corrections The items circled below need clarification, modification or change. to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303 (c), of the Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. All circled items have A. PLANS n- Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: ESA/[- OP JU&~D/~ /oc/ To facilitate rechecking, please identify, next to each circled item, the sheet of the plans upon which each correction on this sheet has been made and return this check sheet with the revised plans. I ~ I PUNS - Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite 1208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. Indicate bn 'the.Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1987 NEC. Submit fully dimensioned plot plan dram to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). Indicate distance from property lines to proposed building. Section 302(d). Section 302(d). Show on the title sheet all structures, pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included .I' Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. On the cover sheet of the plans, specify any items requiring special inspection, by way of the following: In addition to the regular inspections, the following checked items will also require Special Inspection inaccordance with Sec 306 of the Uniform Building Code. REOUIFSD SPECIAL INSTRUCTIONS . Im REQ. IF REMARKS CHECKED SOILS COMPLIANCE r PRIOR TO FOUNDATION Ih'SP. STp.UCTURAL CONCPm OVER 2500 PSI PRESTRESSED STEEL FIELD h'ELDING HIGH STFENGTH BOLTS XPANSION ANCHORS SPECIAL NhSOhXY SPRAYED ON FIRE P23C)FING PILES/ CAISSONS DESIGNER-SPECIFIED Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 12/ 111 89 2 Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor am per floor exceeds 1,000 square feet. Section 1709. Projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 504. Plastic skylights shall not be installed within that portion of a roof located within a distance to property line where openings in exterior walls are'prohibited or required to be protected. Section 5207 (a) .7. , Projections, including eaves, shall be one-, hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1710. Section 1710. Show location of permanently wired smoke detector: a. Centrally located in corridor or area b. On each story. c. In the basement. d. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. e. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in - all sleeping areas of the unit. giving access to sleeping rooms. Section 1210 . men the valuation of a room addition or repair exceeds $1,000, or when sleeping rooms are created, smoke detectors shall be provided zt existing bedrooms per item 19 above. Section 1210. 2/!. Habitable rooms, "other than kitchens, shall contain at least 70 square feet of floor area. At least one room shall have not less than 120 square feet of flocr area. Section 1207 (b). Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). . Appears to be deficient in 2( Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. Section 1205 (a). 21. At least 112 of the common wall must be open and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if light and ventilation is being supplied from an adjacent room. Section 1205 (a). #i. Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of providing five air -changes per hour in -, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. Show discharge point for exhaust air to be at least 5 feet from any mechanical ventilating ,- intake. Section 1205(c). Ductless fans cannot be used in bathrooms if a tub or shover is present. No habitable room, other than a kitchen, shall 9 be less than 7'0'' in any dimension. Section 1207 (c). 4. Show that ceiling height for habitable rooms is a minh of 7'6". 3{. Shov ceiling height for laundry rooms, hallways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). 34 Dinension on the plzns t!ie 30" clear width for l"' wzter closet compartments and 24" clearance in front of water closet. @ Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to doors and glazing adjacent to walking surfaces. Section 5406. Glzzing, in the sane wali plans cs a door, szst be safety gkzing If within 12" of the door and less than 60" above the walking surface, unless the glazing is leaded or faceted glass. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor). Section 1205 (c). Section 1205(c). . Section 1207 (a). Section 511 (a). Section 5406 (d) 6. Section 5406 (d) 5. 21 121 90 3 . provide spiral stairway details, per Section a. Minimum run is 7 112 inches measured at a inches from where the treads are f 3306 (f): point 12 the narrowest. b. Maximum rise is 9 112 inches. MaxirmuP clear opening between risers is 6 inches. c. Minimum headroom is 6 feet 6 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. . Spiral stairways may not .be used for required 5(1 exits when the area served is. greater than 400 sq. ft. Section 3306 (f). 54. Provide I.C.B.O. Research Report and number for metal staiway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior staimays shall not project into the 3 foot setback from the property lines. Section 3306 (n). $. The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m) . Within units, show that corridors have a . si'. minimum width of 36 inches. Section 3305 (b) . ROOPMG 5Q. Specify roof slope. $. Roof slope is not adequate for roof type 4. Specify roof material zid application. Chapter d. Specify I.C.B.O. or U.L. approval number for ' roof materials not ccrered in U.9.C., e.&., tile, etc. Section 157. $ Specify minimum 114 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). z. Show roof drains and overflows. Section 3207. specified. Table 32-BJC,D and E. 32. Provide skylight details -to show compliance 81.C.B.0. with Sections approval 3401 number. and 5207 or provide Plastic skylights must be separated from each other by at least 4 feet. Section 5207 (a) 6. Show attic ventilation. Minimum vent area is 11150 of attic area or 11300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 ( C). "w $. Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. . Show anchored veneer-support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a>. Show ties and 89 wire in horizontal joints. Show height and construction details of all masonry walls. . Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. r Chapter 24. GU%S &LOCK 9. Show a minimum 2" air space and flzshing between planter and building walls. Section 2516 (c) 7. P 7$ Garage requires one-hour fire protection on the garage side of valls md ceiling comcn to the dwelling. . All elements supporting floor above garage, including walls supporting floor joists , must have one-hour fire-resistive protection on the ' garage side. Section 503 (b) #. Show 1 3/8" solid core self-closing door for Section Table 5-B, Section 503 (d). cpsr.;ngs between gzrag.- ax? &*elling. 503 (d). used for sleeping purposes. . Garages are not permitted to open into a room Section 1104. 12/11/89 5 15. All structures require a Class B roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), #en the above exception doesn't 6. City Ordinance 9792 requires two parking i.e. no apply. spaceslunit with char area of 2O'x20' washing machines, etc. Show compliance. 187. All chimneys attached to any appliance or fireplace that bums solid fuel shall be equipped with an approved spark arrester. The net free area of the spark arrester shall be not less than four times the net free ara of the outlet of the chimney. The spark arrester screen shall have heat and corrosion resistance . equivalent to 12 gauge wire, 19 gauge galvanized wire or 24 gauge stainless steel. Openings shall not permit the passage of spheres having a diameter larger than 112-inch and shall not block the passage of spheres having a diameter of less than 318-inch. 0 8. Please see additional corrections, or remarks, on the following page. 189. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 190. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please cheek. 6 0 Yes No The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number 6191560-1468, to perform the plan check for your project. If you have my questions regarding these plan check items, please contact at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 6191438-1161. Thank you. Enclosures : 1. 3. 2/14/90 11 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 02123 (619) 560-1468 PLAN CHECK NO: 90 - qb& SET :T ZDESIGNER PROJECT ADDRESS: /7&3(/ Aou, ?A XAUP 0 0 0 U I The plans transmitted herewith have been~corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially conply with the jurisdiction's building codes when minor deficien- - - cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is €or your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. The applicant's copy of the check list has been sent to: Esgil staff did not advise the applicant contact person that plan check has been completed. 0 Esgil staff - did advise applicant that the plan check has been completed. Person contacted: Date contacted: Telephone # c] REMARKS: By : Enclosures: .,(JDLJF ESGIL CORPORATION 3 -2 a-m OCA .Om UVW ODM c PLUl cBKc31 No: b JuRISDIcrIrn: CITXOFCMZLSBAD Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws 'and ordinances by the Planning Department, Engineering Department or other departments. Present California law maridate5 that residential construction comply with Title 24 and the following model codes: 1988 UBC (eff. 1/1/90) P 1988 UPC (eff. 1/1/90) 1987 NEC (eff. 10/28/87) 1988 UMC (eff. 1/1/90) The above regulations apply to residential construction, regardless of the code editions adopted by ordinance. The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process. note on this list (or a copy) where each correction item has been addressed i.e.. ~lan sheet. specification, etc. Be sure to -close the marked :.ID list when you submit the revised plans. Date plans received by jurisdiction: 3 'A/ - 90 Date plans received by Esgil Corporation: 322- 93 3'.?de93 By: F@&$SWm 7H Applicant contact person: ut PEL)Fioa Telephone: 7a3- 7810 HCYJ2f: PAGEFRMBERS AREKIT IH SXpXCEAS PAGFSIiAVIFGlK) ITEtB mI!G UXREQXRS WEXEDELgl%D. List No. 12, Carlsbad Single Family Dwelling 'and Duplex With All Supplements. Date initial plan check completed: (1988 UBC) TUNS - please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department. f. Indicate on the' Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(a)7. All sheets of plans must be signed by the person responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, €or plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). . Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Provide a statement on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1987 NEC. Submit fully dimensioned plot plan draw to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minh slopes. Section 302(d). Indicate distance from property lines to 7. Section 302(d). f. !* proposed building. Section 302(d). lp! Show on the title sheet all structures? pools, walls, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included .'I . Clearly show if the lower level is a basement '# or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. . On the cover sheet of the plans, specify any by way of items requiring special inspection, the following: REOUIRED SPECIAL INSTRUCTIONS In addition to the reeular insDections. the following checked items- will ilso reqiire Special Inspection of the Uniform Building Code. in-accordance with Sec 306 . ITPI. REQ. IF REMARKS CHECKED SOILS COMPLIANCE r PRIOR TO FOUNDATION INSP. STRUCTURAL CONCPm OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASOhXY SPRAYED ON FIRE PROOFING PILEs/cAIssoxs DESIGNER-SPECIFIED ms pFKmcrI OH Exterior walls closer than 3 feet to property lines shall be one-hour rated construction and have no openings. Table 5-A. 12/ 111 89 2 Exterior walls closer than 3 feet to a property line shall have 30 inch parapets when the floor per floor exceeds 1,000 square feet. Section 1709. projections, including eaves, may not extend more than 12 inches into the 3 foot setback from the property line. Eaves over required windows shall be not less than 30 inches from the side and rear property lines. Section 504. Plastic skylights shall not be. installed within that portion of a roof located- within a distance to property line where openings in exterior walls are prohibited or required to be protected. Section 5207 (a) 7. Projections, including eaves, shall be one- hour fire-resistive construction, heavy timber or of noncombustible material if they project into the 3' setback area from the property line. Section 1710. Show location of pennanently wired smoke detector: a. Centrally located in corridor or area b. On each story. c. In the basement. d. When sleeping rooms are upstairs, at the upper level in close proximity to the stair. e. In rooms adjacent to hallways serving bedrooms, when such rooms have a ceiling height 24 inches or more above the ceiling height in the hallway. NOTE: Detectors shall sound an alarm audible in - all sleeping areas of the unit. When the valuation of a room addition or repair exceeds 81,000, or when sleeping rooms are created, smoke detectors shall be provided at existing bedrooms per item 19 above. Section 1210. Section 1710. giving access to sleeping rooms. Section 1210 CaPrwIII. mZDEHITIAL Habitable rooms, other than kitchens, shall contain at least 70 square feet of floor area. At least one room shall have not less than 120 square feet of floor area. Section 1207 (b). b Window area must be at least 1/10 of the floor area and a minimum of 10 square feet per Section 1205 (a). Appears to be deficient in 2{ Openable window area in habitable rooms must be 1/20 of the floor area and a minimum of 5 square feet. In bathrooms, laundry rooms and similar rooms 1/20 of area is required and minimum is 1.5 sq. ft. Section 1205 (a). 2(. At least 112 of the couunon wall must be open and have an opening not less than 25 sq. ft. nor one tenth of the floor area of the interior room if lid& and ventilation is being supplied from an-adjacent room. 1205 (a). Section (5. Required windows shall not open into a roofed porch unless the ceiling height is at least 7 feet, the longer side is at least 65% open, and the porch abuts a street, yard or court. Section 1205 (a). Provide mechanical ventilation capable of providing five air .changes per hour in -, water closet compartments, laundry rooms and similar rooms if required openable windows are not provided. @- Show discharge point for exhaust air to be at least 5 feet from any mechanical ventilating intake. Section 1205(c). Ductless fans cannot be used in bathrooms if a tub or shower is present. No habitable room, other than a kitchen, shall be less than 7'0" in any dimension. Section 1207 (c). 4. Show that ceiling height for habitable rooms is a minimum of 7'6". Show ceiling height for laundry rooms, 3{' hallways, corridors, and bathrooms is a minimum of 7'0". Section 1207 (a). $. Dimension on the plans the 30" clear width for water closet compartments and 24" clearance in front of water closet. @ Specify safety glazing for glazing in hazardous locations such as glass doors, glazing adjacent to doors and glazing adjacent to walking surfaces. Section 5406. Glazing, in the same wall plane as a door, mast be safety glazing if within 12" of the door and less than 60" above the walking surface, unless the glazing is leaded or faceted glass. Glazing in shower and tub enclosures shall be tempered, laminated or approved plastic (including windows within 5 feet of tub or shower floor). Section 1205 (c). Section 1205(c). . Section 1207 (a). Section 511 (a). Section 5406 (d) 6. Section 5406 (d) 5. 2/12/90 3 Sleeping rooms shall have a window or exterior door for emergency exit. Sill height shall not exceed 44" above the floor. The window must have an openable area of at least 5.7 s we feet with the minimum openable width 20' and the minimum openable height 24". Section 1204. Basements in dwelling units shall comly with the above (even if not designated as sleeping rooms). Section 1204. Walls and floors separating units in a duplex shall be of one-hour fire-resistive construction. Section 1202(b). A mezzanine is an intermediate floor and may not have a floor area exceeding 33 113 percent of the total floor area in the room below. The mezzanine floor must have a clear height of 7 feet, above and below, and must have the long side open to the room below except for posts and protective walls or railings not exceeding 42" in height. Section 1716. The loft you show does not comply as a mezzanine floor and is, by Uniform Building Code definition, a story. 9 Section 1716. Floors above the second story shall have not less than 2 exits. Exceptions: 1. Occupied roofs may have one exit if such occupied areas are less than 500 square feet and located no higher than immediately above the second story. 2. When the third floor within a unit does not exceed 500 sq. ft., only one exit need be provided. Section 3303 (a). Required exit doorways shall be not less than 36' in width and not less than 6'8" in height, and shall be capable of opening at least 90 degrees. Section 3304 (f). Provide 36" high protective railing for porches, balconies, and open sides of stair landings. Openings between railings shall be less than $". Section 1711. Show how guardrail connection details are adequate to support 20 pounds per lineal foot at a right angle to the top rail. Table 23-B. . Provide stairway and landing details. Section a. Maximum rise is 7" and minimum run is 11". When the stairs serves less than 10 occupants, or semes an unoccupied roof, rise may be 8" maximum and run 9'l minimum. b. Minimum headroom is 6'-6". (per Title 24) c. Minimum width is 36". 4p 3306 (b), (c) and (p). handrails per Section 3306 (j), shall satisfy the following: a. Provide handrail for stairways with 4 or more risers. Handrail shall be 34" above the nosing of treads. (per Title 24) The handgrip portion of handrail shall be not less than 1 1/P, nor more than 2" in Every stairway landing shall have a dimension, measured in the direction of travel, at least equal to the stairway width. Such dimension need not exceed 36 inches. Section 3306 (g), 3304 (j). An interior door may open inward at the top step of a stairway provided the top step is not more than 7 112" lower than the floor level. Section 3304 (i). Provide details of winding stairway complying with Section 3306 (d): a. Minimum tread is 6 inches at any point and minimum 9 inches at a point 12 inches from where the treads are narrowest. b. c. . cross-sectional dimens ion. b. Maximum rise is 8 inches. c. Minimum width is 36 inches. . provide spiral stairway details, per Section a. Minimum run is 7 1J2 inches measured at a inches from where the treads are f 3306 (f): point 12 the narrowest. b. Maximum rise is 9 112 inches. Maximum c. Minimum headroom is 4 feet 6 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. . Spiral stairways may not be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). 54. Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior staimays shall not project into the 3 foot setback from the property lines. Section 3306 (n). f+. The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). Within units, show that corridors have a clear opening between risers is 6 inches. . ?* minimum width of 36 inches. Section 3305 (b). ROOPMG 5Q. Specify roof slope. $7. Roof slope is not adequate for roof type 56. Specify roof material and application. Chapter +. Specify I.C.B.O. or U.L. approval number for roof materials not cnvered in U.B.C., e.g., tile, etc. Section 167. $ speciry minimum 114 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). #. Show roof drains and overflows. Section 3207. specified. Table 32-B,C,D and E. 32. Provide skylight details So show compliance with Sections 3401 and 5207 or provide I. C . B. 0. approval number. Plastic skylights must be separated from each other by at least 4 feet. Section 5207 (a) 6. Show attic ventilation. Minh vent area is 11150 of attic area or 11300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). "Kp 6p. Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. Show anchored veneer support and connections p. attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a>. Show ties and #9 wire in horizontal joints. Show height and construction details of all masonry walls. Chapter 24. Gu%sGLDcK . Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. r 9. Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. P 7{ Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). . All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the ' garage side. Section 503 (b) #. Show 1 318'' solid core self-closing door for Section cp;;,ings between gzage and dwellL!g. 503 (d). used for sleeping purposes. . Garages are not permitted to open into a room Section 1104. 12 J il f a9 5 occupancy separation is not required between carport and residence, provided the carport is open on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. Show garage framing sections, size of header Over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: Maximum shear panel height-to-width ratio is 3 112 to 1 for plywood. Table 25-1. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). Provide an 18" raised platform for any FAU, water heater, or other device in the garage which may generate a flame or spark. UMC Section 508, UPC Section 1310 (a). Per soils report, note on the plan the soils classification, whether or not the soil is expansive and note the allowable bearing value. Section 2905 (c). The foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance : Provide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation. Provide a letter from the soils engineer confirming that the foundation plan! grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). The soils engineer recobended that hefshe review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: f- 1. The building pad was prepared in accordance with the soils report, backfilled and compacted, and the intent of the soils report". 2. The utility trenches have been properly 3. The foundation excavations comply with . Show height of all foundation walls. Chapter . Show height of retained earth on all . Jf cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. &. Note on plans that wood shall be 6" minimum above finish grade. Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Dimension foundation per U.B.C. Table 29A: ' 23. f foundation walls. Chapter 23. r P Section 2907 (a). Section 2905 (f). 8/. Floors Footinq Suvporteda Stemwall Width Depth Thickness 1 6" 12" 12" 6" 2 8" 15" 18" 7 'I 3 10" 18" 24" 8" RFoundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. $. Show foundation sills to be pressure treated, Section 2516 (c) 3. or equal. . S~QW foundation bolt size and spacing. Specify size, I.C.B.O. number and manufacturer of power driven pins. Shou edge and end distances and spacing. * Sec:-,ion 2907 (f). . Section 302 (a). 2/13/90 6 . If required, show size, imbedment and location ' of hold down anchors on foundation plan. Section 302 (a). If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 1. Show adequate footings under all bearing walls and shear walls. Section 2907 (b). Show on the plans stepped footings for slopes steeper than 1:lO: Show minimum 18" clearance from grade to bottom of floor joists and minimum 12" clearance to bottom of girders. Show pier size, spacing and depth into undisturbed soil. Table 29-A. Show minimum underfloor access of 18" x 24". Section 2516 (c). Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c) 6. Section 2907 (c). Section 2516 (c) 2. .. 100. Show wall bracing. Every exterior wood stud wall and main cross-stud partition shall be braced at each end at least even 25 feet of 0 length with 1 x 4 diagonal let-& braces or equivalent. Section 2517 (g) 3, Table 25-V. In 2-story buildings, shear panels at the first story (at least 48 inches in width) shall be located at each end or as near thereto as possible and comprise at least 25 percent of the linear length of the wall, or provide design. Section 2517(g)3, Table 25-V. Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held inline. Sec. 2506 (h), 7517 (d) 6. Show blocking at ends and at joists, rafters and trusses Section 2517 (d) 3, 2517 (h) 6. supports of floor at extericr walls. Bearing partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. I&. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 6. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. . Show double top plate with minimum 48" lap 1. splice. Section 2517 (g) 2. . Show nailing will be in compliance with Table '' 25-4. 19. Show or note fire stops at the following locations per Section 2516 (f): P $. C. d. In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals along the length of the wall; At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs are unfinished; and In openings around vents? pipes, ducts, chimneys, fireplaces and smilar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. . In duplexes, draft stops shall be provided in floor-ceiling assemblies and attics in line with walls separating units and separating units from common areas. Maximum allowable stud heights: Bearing wall: 2 x4 and 2 X 6 max. 10'; x 4 max. 14', 2 x 6 max. 20'. Table 25-R-3. 122. Studs supporting two floors, a roof and 1 ceiling mdst be 3 x 4 or 2 x 6 at 16" O.C. 3. Note on A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. 1 1. Show stud size and spacing. Non-bearing: 2 1 I Table 25-R-3. . Detail all post-to-beam and post-to-footing connections and reference the detail to the plan. Section 2516 (m). 115. Detail shear transfer connections, including roof and floor diaphragms, to shear walls. 116. Specify Mil size and spacing for all shear walls, floor and roof diaphragms. Indicate required blocking. Maintain maximum diaphragm dimension ratios. [Tables 25 I, J, K and Section 4714 (d)]. 117. Provide truss details and truss calculations for this project. Specify truss identification 0 Section 2513. 0 0 numbers on the plans; Show 1/2" minimum clearance between top plate of interior partitions and bottom chord of trusses. (To ensure loading will be as designed). Provide roof framing plan and floor framing plan. Section 302 (d). Provide framing sections through Section 302 (d). Specify all header sizes for opening over 4' wide. Section 2517 (g) 5. Provide calculations for main vertical and horizontal framing members and post footings. Section 302 (b). Provide calculations for lateral loads, shear panels, shear transfer and related. Section 302 (b) . In Seismic Zones 3 and 4, the allowable shear wall values for drywall in Table 47-1 must be reduced 50 percent when considering earthquake loads. This does not apply to wind loads. Footnote 1. Show on the plans all structural requirements developed in the structural calculatioris. Section 302 (d). (See comments below GY at end.) . Columns and posts located on concrete or masonry floors or decks exposed to the weather or to water splash or in basements and which support permanent structures shall be supported by concrete piers or metal pedestals projecting above floors unless approved wood of natural resistance to decay or treated wood is used. . Individual concrete or masonry piers shall project at least 8 inches above exposed ground unless the columns or posts which they support are of approved wood of natural resistance to decay or treated wood is used. Section 2516 (c) 4. size 22Il x 30". Section 3205. Section 2516 (c) 4. . Show location of attic access with minimum 19. Show draft separation for attic areas between units in a duplex. lb. Specify plywood and/or particle board thickness, grade and panel identification index. Table 25-S. 1$. When roof pitch is less than 3:12, design ridge as a beam. 1 2. If foundation cripple wall studs are less than / 14" high, framing shall be solid blocking, or sheathed with plywood. shall be 3 inch by 4 inch or 2 inches by 6 inches when sup orting 2 stories. Section 2517 (gp 4. . Show plywood sheathing over exposed eaves, or other weather exposed areas, is "bonded with exterior glue." Plywood used for exterior wall covering shall be the exterior type. Section 2516 (i), 2516(g)3. ld. Detail truss layout for 30" x 30" attic access, if required for equipment in the attic. Section 2516 (f). ,- Section 2517 (h). Section 2517 (g) 4. 3. Cripple wall studs exceeding 4 feet in height Ridges, hips, and valleys shall be at least one size larger than supported rafters. Section 2517 (h) 3. 1 7. In opa beam construction, previde strap ties across the beams at the ridge support. Section 2501 (b). f All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. show the size, location and type of all heating and cooling appliances or systems. SOW source of combustion air to furnace, per Chapter 6, UnC. Every dwelling unit shall be provided with heating facilities capable of maintaining a room temperature of 70 degrees F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. 1. show minimum 30" deep unobstructed working space in front of furnace. not be installed in any bedroom, bathroom or in a closet or access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UHC. fireplace. Show height of chimney above roof per I.C.B.O. approval or Table 37-B. . show access to the attic containing equipment to be minh 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 708 WC. Section 505, UMC. confined space with. . wce shall . show I.C.B.O. approval number for prefab 14. Where equipment is installed in the attic, the distance from the attic access to such equipment shall not exceed 20 feet. #. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 2h inches wide. Section 708 UHC. 1 7. Show permanent electrical outlet and lighting ' fixture controlled by a switch for the attic furnace. Section 708 LMC. l+. Show details to comply with Section 709 for furnace under the floor, or Section 710 for roof or outside furnace. 149. Note on plan: Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (a) 6. . Provide dryer vent to outside. UMC, Section llfo 1903. - ELEclRIchG (RATIONAL mchG CODEL All wiring shall comply with the National Electrical Code. . Show on the plan the amperage of the electrical service, the location of the service panel and the location of any sub- panels. If service is over 200 amps, submit single line diagram, peel schedule and load calculations. 1J1 $2. sow location of all electrical receptacles. '38 is not adequate in . Electrical receptacle locations and/or spacing 151f: Show at least one convenience outlet other than outlets for laundry, etc., outdoors, in garages and basements. hTC, Art. 210-52. counter top(s) within 6 feet of the kitchen sink, outdoors, and in garages and basements (other thn for laundry and similar equipment) shall be GFI protected. h'EC, Art. 210-8. 1 6. Note electrical system ground to be provided mm ul" mRlBlRG CODIS) Ef. Show water heater size, type and location on plans. UPC, Section 1301. 1 8. Show source for providing combustion air to fuel burning water heater. If wall openings in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one-half within the lower twelve inches. UPC, Section 1307. Note convenience outlets in bathrooms, kitchen 7 per hTC, Art. 250-81. 3 9. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. UPC, Section 1309. . Provide adequate barrier to protect water heater from vehicle damage. An 18" platform for the water heater does not satisfy this requirement. UPC, Section 1310. . Show T and P valve on water heater and show route of discharge line to exterior. P 'f UPC, Section 1007 (e). 1/19/90 9 n Show that water heater is adequately braced to resist seismic forces, when not connected by rigid pipe. UMC Section 504(d). Show shower stall can accommodate a 30" circle and has a minimum floor area of 1,024 sq. in. UPC 909 (d). Provide clothes washer hook-up for each unit. Title 24, Part 3. Show details of duplex cornon (party) walls and f loor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibels and an Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibels. Title 24. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 24. Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident. Title 24. ENERGY C(HISWVATJ0N rovide plans, calculations and worksheets to show compliance with current energy standards. 0 e regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. items shown on the plans must be in agreement with the information shown on the properly completed Form CF-1R. 11. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, Wandatow fierrty Conservation Requirements". 170. All energy 0 il Show the make, model and efficiency of the space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr. For room additions, show that the glazing area of the addition does not exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition. 14. Provide fluorescent general lighting in f kitchen(s) per CAC, Title 24, 2-5352(J). 0 S.P.D. & DUPLEX SWPUWWI n 175. Energy conservation design should be for Zone 16. Floor drains must have auto-prime (city v 7. I policy). , Note exhaust fans cannot be ductless type (city policy). be pre-plumbed for future solar water heating.. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). 1 9. Note "two 314" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). . New residential units must f 0. All piping for present or future solar water heating must be insulated when in areas that are not heated or cooled by mechanical means (city policy). . Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry wall ( s ) . Show on the Title Sheet on the plans, the information required by the attached Developmental Services Sheet 112383. additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City to place their soils notice stamp on the All new residential buildings, including plans. 4. Heavy timber framing, minimum 6" x 10" beams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). 2/26/90 10 $5. $6- All structures require a Class B roof covering, except room additions. If a room addition covers all of the existing building (2nd story addition), then the above exception doesn't apply. City Ordinance 9792 requires two parking spacesfunit with clear area of 20'x20' i.e. no washing machines, etc. Show compliance. 187. All chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. The net free area of the spark arrester shall be not less than four times the net free ara of the outlet of the chimney. .The spark arrester screen shall have heat and corrosion resistance equivalent to 12 gauge wire, 19 gauge galvanized wire or 24 gauge stainless steel. Openings shall not permit the passage of spheres having a diameter larger than 112-inch and shall not block the passage of spheres having a diameter of less than 3/8-inch. 0 HISZUMEQUS 8. Please see additional corrections, or remarks, on the following page. 189. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. 190. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. 6 0 Yes No The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact &/LFf?d FA&.klKL30&%G at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 6191438-1161. Thank you. Enclosures: 1. 2. Dated:qa-m Jurisdiction - BUILDING PORTION EurLmc AREA r DVh ADD17 IO 3 3179 - VALUATION AND PUN CHECK FEE VALUATION VALUE MU LT T P LI ER bf; OD 2 L55LJ. I r Bldg. Dept, 0 Esgil \ 1 I I Air Conditioninn Commercial . Residentizl @ @ -I Res. or Corn. -. Fire Sprinklers @ Total Value I w 2/5-..6. BUILDING OCCUPANCY 4-3 DESIGNER PHONE TYPE OF CONSTRUCTION Vd CONTRACTOR PHONE .. Buildin'g Permit Fee. $ s AAS*oa $. 1% .25 Plan Check Fee $ .. COMMENTS: . SHEET f OF 1 12/87 P 1 S T BUILDING PLANCHECK ENGINEERING CHECKLIST DATE : 3-26 -?o ITEM COMPLETE PLANCHECK NO. 90 -&66 ! 0 ITEM INCOMPLETE - NEEDS YOUR ACTION 2 3 /7&& 174 4J X ITEM SELECTED 1 NR DD C C C PROJECT ID: D%n* 14);lao 1.77044 HHH E E E LEGAL REQUIREMENTS ccc K K K Site Plan 1. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and ro osed structures, streets, existing street improvements,&+f- Show on site plan: 6h floo elevations of finish grade ad g, existing topographical 1 i nes, exi sting and proposed slopes, driveway with percent (%) grade and@raimjx! 0 do 'wayTiZjGTXlT'J2ind dimensioned setbacks. 2. el evat i Gi$? 3. Provide legal description and Assessors Parel Number. Discretionary ADDrOVal ComDliance 4. 5. Project complies with all Engineering Conditions of Approval No Discretionary approvals were required. for Project No. 6. Project does not comply with the following Engineering Conditions of Approval for Project No. Conditions complied with by: Date: Field Review 7. Field review completed. No issues raised. 8. Field Review completed. The following issues or discrepancies with the site plan were found: A. Site lacks adequate public improvements. B. Existing drainage improvements not shown or in conflict with site plan. C. Site is served by overhead power lines. FRM0010.DH D. Grading is required to access site, create pad or provide for ultimate street improvement. 08/29/89 Q E. Site access visibility problems exist. Provide onsite turnaround'or engineered solution to problem. F. Other: Dedication Reauirements )(. 9. No dedication required. 10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate 1 egal descri pt i on together with an 8k" x 11" plat map and submit with a title report and the required processing fee. A1 1 easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as fol 1 owsf Dedication completed, Date: By: ImDrovement Reauirements . No public improvements required. SPECIAL NOTE: Damaqed or defective imorovements found ad.iacent to buildinq site must be reDaired to the satisfaction of the City insoector Drior to OccuDancY. 12. Pub1 ic improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit. for separate pl ancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: Improvement plans signed, Date: By : FRMOO 10. DH 08/29/89 13. Improvements are required. Construction of the pub1 ic improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a letter requesting deferral - of the required improvements together with a recent title report on the property and the appropriate processing fee so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date By : Gradincl Reauirements 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, f i 11 , import, export). No grading required as determined by the information provided on the site plan. 14. 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Gradinq Permit must be issued and qradinq substantially comDlete and found acceDtable to the City InsDector Drior to issuance of Building Permits. Grading Inspector sign off. Date: By: Mi scel 1 aneous Permits > 16. Right-of-way Permit not required. 17. Right-of-way Permit required. A separate Right-of-way Permit issued by the Engineering Department is required for the fol1 owing: y. 18. Sewer Permit is not required. concurrent with Bui 1 ding Permit i ssuance. is noted below in the fees section. Industrial Waste Permit is not required. 19. Sewer Permit is required. A Sewer Permit is required The fee required )(. 20. FRMOO 10. DH 00/ 2 9/09 21. Industrial Waste Permit is required. Applicant must complete Industri a1 Waste Permit Appl i cant i on Form and submit for City - approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industri a1 Waste Permit accepted - Date: By: Fees Reau i red +22. qh 23. 24. $kl 25. &!!A 26. +27. .Mj9 20. Park-in-Lieu Fee Quadrant: - Fee per Unit: Total Fee: Traffic Impact Fee Fee Per Unit: L Total Fee: ml& I_ Bridge and Fee per Un Pub1 ic Fac Facilities Sewer Fees Thoroughfare Fee t: lities Fee required. Total Fee: - Management Fee Zone: Fee: f Fee: Amit No. - EDU's 9awz~- Fee: m ENGINEERING AUTHORIZATION TO ISSUE PERMIT - Date: %4/Zo FRMOOlO . DH 08/29/09 du 0 n do 0 PLANNINb CHECKLIST Plan Check No. '%% Address APN : P1 anner Phone 438- 1161 Type of Project and Use SP (Name) Zone A+/ Faci 1 i ties Management Zone / a Item Complete @ Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified Environmental Review Required: YES NO - TYPE DATE OF COMPLETION: Compl'iance with conditions of approval? If not, state conditions which require action. Conditions of Approval Discretionary Action Requited: YES NO - TYPE APPROVAL/RESO. NO. DATE: PROJECT NO. * OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Condi tiont of Approval Coast a1 : YES NO - DATE OF APPROVAL: Compliance with conditions of approval? If not, state conditions which require action. Condi ti ons of Approval 8'0 * 00 0 uo n nu 0 Landscape PI an Required: YES NO See attached submittal requirements for 1 andscape pl anr Site Plan: 1. 2. 3. 4. . Zoning: 1. 2. 3. 4. Additional Provide a fully dimensioned site plan drawn to scale. Snow: North arrow, property lines, easements, existing and proposer, structures, streets, existing street improvements, right-of -waj width and dimensioned setbacks. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical 1 ines, existins and proposed slopes and driveway. Provide legal description of property. i' Provide assessor's parcel number. Setbacks : Front: Requ i red Shown Int. Side: Requ i red Shown Street Side: Requ i red Shown Rear: Requ i red Shown Lot coverage: Requ 5 red Shown Height : Requ i red Shown Parking: Spaces Required Shown Guest Spaces Required Shown corents and remarks have been made on the buildinq ~lans. These marked-up plans may be picked up at the Building Depart#nt.- These marked- up plans must be ksubaitted with the revised plans for this project. Have plans been marked up? YES NO Additional Comnents - OK TO ISSUE DATE