Description: DICENSO: REMOVE EXISTING 2ND STORY DECK AND REPLACE WITH CITY STANDARD 200 SF DECK, REPLACE 2 SLIDING
DOORS (NO FRAME WORK, SAME LOC)
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
S81473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $121.56
Owner:
ROBERT DICENSO
1735 Geranium St
CARLSBAD, CA 92011
Total Payments To Date:
Contractor:
BERNARD KING CONSTRUCTION
3941 El Canto Dr
Spring Valley, CA 91977-1715
$121.S6 Balance Due: $0.00
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
$70.61
$49.43
$1.00
$0.52
Ccicyof
Carlsbad
RESIDENTIAL
BUILDING PERMIT
APPLICATION
B-1
Plan Check IBRi<J19 -o?DI
Est. Value ~ IJ, CXJ{g • @
PC Deposit --~---1-·----
D ate -=aµ( '6.L/-/...J_j 9_,______
Job Address __ \_1----'3'-"'S:---=4:t:<'::"-'""'. =0rv...._1...,•u""'=--C--,..__M-=."iw$-LQ,.~,.4--D...,,,.____~ite: ____ APN: __________ _
CT/Project#: __________ Lot#:, ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no
BRIEF DESCRIPTION OF WORK: _13u..:1 :.::.,,;' l::.;1:>><-----'M½i"""",,.,_----'J:,,...,""'="'k::=-,/<......,f'...,..,;9~_.,"=-'C0....__'2..-__t;.o::.,,(,..,.,,ubo..._L.._.~..._ __ _
~ Addition/New: _____ Living SF, ~~~~D~e~ck~S~F~~='.=-Patio SF, ___ Garage SF
Is this to create an Accessory Dwelling Unit? Yes o New Fireplace? Yes/ No, if yes how many? __
D Remodel: _____ SF of affected area Is the area a conversion or change of use? Yes/ No
□ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _
□ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No
Panel Upgrade: Yes/ No
D Reroof: ___________________________________ _
D Plumbing/Mechanical/Electrical Only: ________________________ _
D Other:-----------------------------------
APPLICANT {PRIMARY CONTACT) PROPERTY OWNER
Name: -:e,~ .......... ......,..,, lu \c.. • ~'i ---Name: 'll.. a,....,._K D I ( 12 !hi'-o
Address: 3"1 '-<, E.t.. < kryro :t)ft-.-Address: 11 ;!,£ G: 41'1 "='' _. ....
City: S/'fl1,'"1 v,,,J1.., State: CA Zip: '11i'"17 City: Ca+lhM:i> State:~ Zip: &j l-o1\
Phone: let 'l -'-fl S::: -?. S" .S\ Phone: 7 <, O • '-l 7 } · I O 7 2-
Email:~""-b CL ~Ml k,,~c•s:ni.uJ • .,. Cqnmail: ____________________ _
DESIGN PROFESSIONAL
Name: _________________ _
CONTRACTOR BUSINESS
Name: "3..ui.w4fi'i> \<-., -" C..,....,,-au,_4, •&
Address: ________________ _
City: ________ State: ___ .Zip: ____ _
Phone: _________________ _
Address: Z l:?.'f \/, Pr Q<LA:r,.,;,s, C..•6f ~ 107
City: sr,i,, ":5 y,Jl'7 State: C+\ Zip: "'h "17 '6
Phone: /,t'{ -"i 15"-35" 3 f
Email: _________________ _ Email: MJ>. 1£,
Architect State License: ___________ _ State License: 'a16<l..,_ ~~ Bus. License:__,1~11,.1111-LJl.21.--
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its
issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law
{Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged
exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}).
1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov
B-1 Page 1 of 2 Rev. 06/18
( OPTION A): WORKERS'COMPENSATION DECLARATION:
I hearby affirm under penalty of perjury one of the following declarations:
□ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the
work which this permit is issued.
9,J..have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
My workers' compensation insurance carrier and policy number are: Insurance Company Name: 2'!:\! ( I e ?T fC1..t.r1'» e k ~ rvk Co ......
Policy No. 7 I, o O <l I~ 3 8 11 8 \ Expiration Date: 1 <-[ 1 [ tq
□ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come
subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to
criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code,
Interest and attorney's fees.
CONTRACTOR SIGNATURE: _'"'Z.._..::::.-e:::A::....ll==,.::!L-----------□AGENT DATE: _,.2-~---'"'---'-'\,___
( OPTION B ): OWNER-BUILDER DECLARATION:
I hereby affirm that I am exempt from Contractor's license Low for the following reason:
□ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec.
7044, Business and Professions Code: The Contractor's license law does not apply to an owner of property who builds or improves thereon, and who does such work
himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within
one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
□ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The
Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed
pursuant to the Contractor's license Law).
□ I am exempt under Section ________ Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No
2. I (have/ have not) signed an application for a building permit for the proposed work.
3. r have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number):
4. l plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/
contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work):
OWNER SIGNATURE: □AGENT DATE: _____ _ ----------------------
CONSTRUCTION LENDING AGENCY, IF ANY:
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name: _____________________ _ Lender's Address: _____________________ _
ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY:
rs the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention
program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPAN(.Y MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
APPLICANT CERTIFICATION:
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all
City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of carlsbad to enter upon the above mentioned property for inspection purposes. I Al50 AGREE TO SAVE, INDEMNIFY AND KEEP
HARMLESS THE CITY OF CARISBADAGAINST ALL LIABILITIES, JUDGMENTS, COS'TS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF
THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized
by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time
after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
APPLICANT SIGNATURE: ~ A :--cit
1635 Faraday Ave Carlsbad, CA 92008
8-1
Ph: 760-602-2719 Fax: 760-602-8558
Page 2 o/2
DATE: ~z_~--~_-_1~"----
Email: Building@carlsbadca.gov
Rev. 06/18
PERMIT INSPECTION HISTORY REPORT (CBR2019-0301)
Permit Type: BLDG-Residential Application Date: 02/08/2019 Owner: ROBERT DICENSO
Work Class: Deck Issue Date: 02/27/2019 Subdivision: CARLSBAD TCT#79-04
Status: Closed -Finaled Expiration Date: 10/21/2019 Address: 1735 Geranium St
Carlsbad, CA 92011-5118
IVR Number: 16944
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
03/01/2019 03/01/2019 BLDG-11 085019-2019 Passed Tlm Frazee Complete
Foundatlon/Ftg/Pler
s (Rebar)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency 3-#4 each way OK to pour Yes
04/0112019 04(01/2019 BLDG-14 087560-2019 Failed Paul Burnette Reinspectlon Complete
Frame/SteelfBoltlng/
Welding (Decks)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-17 Interior 087559-2019 Failed Paul Burnette Reinspection Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLOG-Building Deficiency No
04/02/2019 04/02/2019 BLDG-14 087695-2019 Passed Paul Burnette Complete
Frame/Steel/Bolting/
Welding (Decks)
Checklist Item COMMENTS Passed
BLOG-Building Deficiency No
BLDG-18 Exterior 087767-2019 Passed Paul Burnette Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
04/22/2019 04/22/2019 BLDG-Flnal 089570-2019 Failed Paul Burnette Reinspection Complete
Inspection
Checklist Item COMMENTS Passed
BLOG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLOG-Electrical Final No
04/25/2019 04/25/2019 BLDG-Final 089937-2019 Passed Paul Burnette Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
BLDG-Plumbing Final No
BLDG-Mechanical Final No
BLDG-Structural Final No
BLDG-Electrical Final No
April 25, 2019 Page 1 of 1
( City of
Carlsbad
RESIDENTIAL
DECKS
B-4
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www .carlsbadca.gov
8-4
A Building Permit is required for residential decks more than 30" above grade and must comply with
the Zoning Ordinance, including building setbacks, structure separation requirements and lot coverage.
This hand out describes what plans are necessary to secure a deck permit. To assist you, there is a
sample of a plot plan, span tables for joists, girders, and beams, and there is a footing schedule for
foundation requirements. There are also connection details to use for typical connections. If you design
the deck yourself, or if your deck is free-standing or outside the table limits in this handout, please
provide a foundation plan, framing details, and other details and elevations to show the extent of the
proposed work. A complete structural analysis may be required for decks outside the scope of this
handout.
If you use the attached tables and plans please submit:
1. Two Identical Site Plans showing:
a. Property lines with dimensions.
b. Proposed deck and stairway (if applicable).
c. Distances from posts to property lines.
d. All existing structures on the property.
e. Indicate the dimensions of the deck and the total deck square footage.
f. Any easements on the property.
g. Percentage of lot coverage.
2. A Building Permit Application with the following:
a. Name of the property owner.
b. Home Phone Number
c. Site address, assessor's parcel number, lot number, subdivision name or number.
d. Contractor's name, State License Number and City Business License Number; or an
Owner-Builder Declaration Form (Available at the Building Division Counter).
e. Signature of Applicant
If you are applying for a building permit in a subdivision with a homeowner's association, you
should secure architectural review prior to proceeding with the project. The City does not enforce or
specifically review provisions of homeowners' association CC&R's. HOA requirements may be different
than City requirements.
If you are applying for a building permit in the Coastal Zone, you may need a Coastal Development
Permit or an exemption. Contact the Planning Division for details. A Coastal Zone map is part of this
handout. If you are applying for a building permit in a subdivision with a homeowner's association, you
should secure architectural review prior to proceeding with the project. The City does not enforce or
specifically review provisions of homeowners' association CC&R's. HOA requirements may be different
than City requirements. If your home is part of a Planned Unit Development or a condominium, please
see text of this handout.
Page 1 of 6 Rev. 03/09
SETBACKS FOR R-1 PARCELS
FRONT V JIRO -20' from front
property line
INTERIOR SIDE V ARO -1 Oo/o of
lot width,_.., to a maxa,un of
1 O'
STREET SIDE V ARO -1 O'
REAR V NW -20% of lot wlclh
up to maximtMn of 20 feet
MAX. LOT COVERAGE -40%
Contact the Planning Oepartmenl
for lnfOl'l1\lltion on corner lots or
lots with t.nUsual configurations
and for lntormetlOn on Plenned
Communlies, accesso,y
structu-es, and building
heights.
Thetelephoneno..imi-torthe Pl...,,.,.,. o..ru.rtrnent Is
602-4610.
1
20% of LOT
( REARYARO WOTHTOA
MAX.~ 20'
PROPOSED
AOOmON
-, 10% ~
EXISTNO RESOENCE
~ I
~ DRANAOE 2% MIii. ---------1-
20'
I , l
J
STREET
\
10
LO
%OF
TVlllOTH
TOA u>
L-A:::. v MAX.OF 10'
j/
--
£
_..LOT
F
'IM)TH MEASURED 20'
ROM 20' BAO< OF
F RONT PROPERTY LINE
~ PROPERTY LN: L----
Minimum Square Footing Sizes (inches)1•2
Post Joist Span (in feet) Spacing ~
4 6 ~J 10 · 12 ' 14 16 1B
4 12 14 16 18 20 20 22 24
6 14 16 20 22 24 24 28 30
~ ~.,.......,_
( s') M 20 22 04) 26 28 30 32
--
10 18 22 24 28 30 32 34 36
12 20 24 28 32 32 36 36 38
1. Assumes 1,000 psf soil bearing capacity
2. The minimum depth for all footings is 12 inches into natural grade
B-4 Page 2 of 6 Rev. 03/09
I
f
B-4
Post
Spacing
4
6
(13
10
12
Allowable Joist Sizes
~sts~
Joist Span Joist Spacing Size of
glas Redwood Joist
6'3" 6'3" 12"
5'6" 5'6" 16" 2x4
5'0" 5'0" 24"
9'9" 9'9" 12"
8'9" 8'9" 16" 2x6
7'9" 7'9 24" en 12'9" d9 '11 '9"
. 2x8 11 '9"
10'2' 10'2"
16'5" 16'5" 12"
15'0" 15'0" 16" 2 X 10
13'0" 13'0" 24"
20'0" 20'0" 12"
18'0" 18'0" 16" 2 X 12
15'10" 15'10" 24"
22'9" 22'6" 12"
19'9" 21 '0" 16" 2 X 14
16'0" 17'0" 24"
1. Assumes a live load of 40 psf and a dead load of 8 psf.
2. If joists are within 18" of grade, use pressure treated Douglas Fir-Larch or Foundation Grade Redwood
3. Assume F(b)=825 psi, F9v)=90 psi, and E=1,200,000 psi for D.F. #2
4. Assume F(b)=925 psi, F9v)=80 psi, and E=1 ,200,000 psi for Redwood
Allowable Beam Sizes
' Joist Span (in feet)
4 6 8 10 12 1.4 16
4x4 4 x6 4 x6 4x8 4 X 10 4 X 10 4 X 14
4x6 4x8 4x8 4 X 10 4 X 10 4 X 14 4 X 14
6x8 6x8 6 X 10 6 X 12
4 X 10 4 X 10 4 X 12 4 X 14 4 X 14 4 X 14 4 X 16
6x8 6x8 6 X 10 0,X I I,!)___. 6 X 10 6 X 12 6 X 12
4 X 10 4 X 14 4 X 14 4 X 16 4 X 16 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6 X 14 6 X 14 6 X 14
4x 10 4 X 14 4 X 14 4 X 16 4 X 16 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6 x14 6 X 14 6 X 14
Page 3 of 6 Rev. 03/09
B-4
Figure 4/Typical deck elevation looking parallel to rear of dwelling
T
Greater than 4'-0"
l
For ledger-to-house
comection use two
3/8"0xs• lag bolts at 16" on
center maximum for joist
spans up to 22'-0" and 32"
on center maximum for
joists spans up to 11·-0•.
Distance from edge of 2x6
minimum ledger to center
of bolt 10 be 1112•
minimum.
Figure 5/Typical pad footing
8" to natural grade from top of
footing for isolated pier footings
Simpson CB or
equivalent
Figure &/Typical deck elevation facing rear of dwelling
Decking
Girder
T If greater than
4 •-0• provide
braces at
post-to-beam
connections
_i_
~ 3·-0· maximum ~
Page 4 of 6
42"
minimum
Use two 112·0xs· bolts
through 2x6 joists
minimum at 3'-0"
maximum on center.
Distance from edge of
member 10 center of bolt
to be 11/i minimum.
Rev. 03/09
' I
B-4
Typical deck
Min. 18ga.
U-type hanger
Post-to-girder connection
ea .. 1/End a>ndition
Post cap
inataled per
manufac1Ll'er's
installation
inatnlctions
~24; maxmum,-.i i,,.E1a-minimum Provide 4x4
knee brace or
~to-botmm brac:eonlhe inlllrior side of all post-to-beam
oonneetions when post
height exceeds 4·-0·
ea .. 2/lnterior condition
Post cap
installed per
manufacturer's instalalion
instructions
18* minimum)li,j
~~~~
Two 1/2 "0 lag ~--I...--bolts top and ---1...----"!IIJI
bottom fypical