Loading...
HomeMy WebLinkAbout1735 Geranium St; ; CBR2019-0301; Permit(city of Carlsbad Residential Permit Print Date: 04/25/2019 Permit No: CBR2019-0301 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 1735 Geranium St BLDG-Residential 2155503000 $4,006.00 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Deck Status: Applied: Issued: Permit Finaled; Inspector: Closed -Finaled 02/08/2019 02/27/2019 PBurn Plan Check#: Final Inspection: 4/25/2019 10:13:25AM Project Title: Description: DICENSO: REMOVE EXISTING 2ND STORY DECK AND REPLACE WITH CITY STANDARD 200 SF DECK, REPLACE 2 SLIDING DOORS (NO FRAME WORK, SAME LOC) BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLDG) S81473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $121.56 Owner: ROBERT DICENSO 1735 Geranium St CARLSBAD, CA 92011 Total Payments To Date: Contractor: BERNARD KING CONSTRUCTION 3941 El Canto Dr Spring Valley, CA 91977-1715 $121.S6 Balance Due: $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $70.61 $49.43 $1.00 $0.52 Ccicyof Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check IBRi<J19 -o?DI Est. Value ~ IJ, CXJ{g • @ PC Deposit --~---1-·---- D ate -=aµ( '6.L/-/...J_j 9_,______ Job Address __ \_1----'3'-"'S:---=4:t:<'::"-'""'. =0rv...._1...,•u""'=--C--,..__M-=."iw$-LQ,.~,.4--D...,,,.____~ite: ____ APN: __________ _ CT/Project#: __________ Lot#:, ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no BRIEF DESCRIPTION OF WORK: _13u..:1 :.::.,,;' l::.;1:>><-----'M½i"""",,.,_----'J:,,...,""'="'k::=-,/<......,f'...,..,;9~_.,"=-'C0....__'2..-__t;.o::.,,(,..,.,,ubo..._L.._.~..._ __ _ ~ Addition/New: _____ Living SF, ~~~~D~e~ck~S~F~~='.=-Patio SF, ___ Garage SF Is this to create an Accessory Dwelling Unit? Yes o New Fireplace? Yes/ No, if yes how many? __ D Remodel: _____ SF of affected area Is the area a conversion or change of use? Yes/ No □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ □ Solar: ___ KW, ___ Modules, Mounted: Roof/ Ground, Tilt: Yes/ No, RMA: Yes/ No, Battery: Yes/ No Panel Upgrade: Yes/ No D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ D Other:----------------------------------- APPLICANT {PRIMARY CONTACT) PROPERTY OWNER Name: -:e,~ .......... ......,..,, lu \c.. • ~'i ---Name: 'll.. a,....,._K D I ( 12 !hi'-o Address: 3"1 '-<, E.t.. < kryro :t)ft-.-Address: 11 ;!,£ G: 41'1 "='' _. .... City: S/'fl1,'"1 v,,,J1.., State: CA Zip: '11i'"17 City: Ca+lhM:i> State:~ Zip: &j l-o1\ Phone: let 'l -'-fl S::: -?. S" .S\ Phone: 7 <, O • '-l 7 } · I O 7 2- Email:~""-b CL ~Ml k,,~c•s:ni.uJ • .,. Cqnmail: ____________________ _ DESIGN PROFESSIONAL Name: _________________ _ CONTRACTOR BUSINESS Name: "3..ui.w4fi'i> \<-., -" C..,....,,-au,_4, •& Address: ________________ _ City: ________ State: ___ .Zip: ____ _ Phone: _________________ _ Address: Z l:?.'f \/, Pr Q<LA:r,.,;,s, C..•6f ~ 107 City: sr,i,, ":5 y,Jl'7 State: C+\ Zip: "'h "17 '6 Phone: /,t'{ -"i 15"-35" 3 f Email: _________________ _ Email: MJ>. 1£, Architect State License: ___________ _ State License: 'a16<l..,_ ~~ Bus. License:__,1~11,.1111-LJl.21.-- (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. 9,J..have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: 2'!:\! ( I e ?T fC1..t.r1'» e k ~ rvk Co ...... Policy No. 7 I, o O <l I~ 3 8 11 8 \ Expiration Date: 1 <-[ 1 [ tq □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation Laws of California. WARNING: Failure to secure workers compensation coverage Is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100,000.00, in addition the to the cost of compensation, damages as provided for in Section 3706 of the Labor Code, Interest and attorney's fees. CONTRACTOR SIGNATURE: _'"'Z.._..::::.-e:::A::....ll==,.::!L-----------□AGENT DATE: _,.2-~---'"'---'-'\,___ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's license Low for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's license law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's license Law). □ I am exempt under Section ________ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. r have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. l plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: □AGENT DATE: _____ _ ---------------------- CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code). Lender's Name: _____________________ _ Lender's Address: _____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: rs the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPAN(.Y MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of carlsbad to enter upon the above mentioned property for inspection purposes. I Al50 AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARISBADAGAINST ALL LIABILITIES, JUDGMENTS, COS'TS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code). APPLICANT SIGNATURE: ~ A :--cit 1635 Faraday Ave Carlsbad, CA 92008 8-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 o/2 DATE: ~z_~--~_-_1~"---- Email: Building@carlsbadca.gov Rev. 06/18 PERMIT INSPECTION HISTORY REPORT (CBR2019-0301) Permit Type: BLDG-Residential Application Date: 02/08/2019 Owner: ROBERT DICENSO Work Class: Deck Issue Date: 02/27/2019 Subdivision: CARLSBAD TCT#79-04 Status: Closed -Finaled Expiration Date: 10/21/2019 Address: 1735 Geranium St Carlsbad, CA 92011-5118 IVR Number: 16944 Scheduled Actual Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete 03/01/2019 03/01/2019 BLDG-11 085019-2019 Passed Tlm Frazee Complete Foundatlon/Ftg/Pler s (Rebar) Checklist Item COMMENTS Passed BLOG-Building Deficiency 3-#4 each way OK to pour Yes 04/0112019 04(01/2019 BLDG-14 087560-2019 Failed Paul Burnette Reinspectlon Complete Frame/SteelfBoltlng/ Welding (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-17 Interior 087559-2019 Failed Paul Burnette Reinspection Complete Lath/Drywall Checklist Item COMMENTS Passed BLOG-Building Deficiency No 04/02/2019 04/02/2019 BLDG-14 087695-2019 Passed Paul Burnette Complete Frame/Steel/Bolting/ Welding (Decks) Checklist Item COMMENTS Passed BLOG-Building Deficiency No BLDG-18 Exterior 087767-2019 Passed Paul Burnette Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency No 04/22/2019 04/22/2019 BLDG-Flnal 089570-2019 Failed Paul Burnette Reinspection Complete Inspection Checklist Item COMMENTS Passed BLOG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLOG-Electrical Final No 04/25/2019 04/25/2019 BLDG-Final 089937-2019 Passed Paul Burnette Complete Inspection Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No April 25, 2019 Page 1 of 1 ( City of Carlsbad RESIDENTIAL DECKS B-4 Development Services Building Division 1635 Faraday Avenue 760-602-2719 www .carlsbadca.gov 8-4 A Building Permit is required for residential decks more than 30" above grade and must comply with the Zoning Ordinance, including building setbacks, structure separation requirements and lot coverage. This hand out describes what plans are necessary to secure a deck permit. To assist you, there is a sample of a plot plan, span tables for joists, girders, and beams, and there is a footing schedule for foundation requirements. There are also connection details to use for typical connections. If you design the deck yourself, or if your deck is free-standing or outside the table limits in this handout, please provide a foundation plan, framing details, and other details and elevations to show the extent of the proposed work. A complete structural analysis may be required for decks outside the scope of this handout. If you use the attached tables and plans please submit: 1. Two Identical Site Plans showing: a. Property lines with dimensions. b. Proposed deck and stairway (if applicable). c. Distances from posts to property lines. d. All existing structures on the property. e. Indicate the dimensions of the deck and the total deck square footage. f. Any easements on the property. g. Percentage of lot coverage. 2. A Building Permit Application with the following: a. Name of the property owner. b. Home Phone Number c. Site address, assessor's parcel number, lot number, subdivision name or number. d. Contractor's name, State License Number and City Business License Number; or an Owner-Builder Declaration Form (Available at the Building Division Counter). e. Signature of Applicant If you are applying for a building permit in a subdivision with a homeowner's association, you should secure architectural review prior to proceeding with the project. The City does not enforce or specifically review provisions of homeowners' association CC&R's. HOA requirements may be different than City requirements. If you are applying for a building permit in the Coastal Zone, you may need a Coastal Development Permit or an exemption. Contact the Planning Division for details. A Coastal Zone map is part of this handout. If you are applying for a building permit in a subdivision with a homeowner's association, you should secure architectural review prior to proceeding with the project. The City does not enforce or specifically review provisions of homeowners' association CC&R's. HOA requirements may be different than City requirements. If your home is part of a Planned Unit Development or a condominium, please see text of this handout. Page 1 of 6 Rev. 03/09 SETBACKS FOR R-1 PARCELS FRONT V JIRO -20' from front property line INTERIOR SIDE V ARO -1 Oo/o of lot width,_.., to a maxa,un of 1 O' STREET SIDE V ARO -1 O' REAR V NW -20% of lot wlclh up to maximtMn of 20 feet MAX. LOT COVERAGE -40% Contact the Planning Oepartmenl for lnfOl'l1\lltion on corner lots or lots with t.nUsual configurations and for lntormetlOn on Plenned Communlies, accesso,y structu-es, and building heights. Thetelephoneno..imi-torthe Pl...,,.,.,. o..ru.rtrnent Is 602-4610. 1 20% of LOT ( REARYARO WOTHTOA MAX.~ 20' PROPOSED AOOmON -, 10% ~ EXISTNO RESOENCE ~ I ~ DRANAOE 2% MIii. ---------1- 20' I , l J STREET \ 10 LO %OF TVlllOTH TOA u> L-A:::. v MAX.OF 10' j/ -- £ _..LOT F 'IM)TH MEASURED 20' ROM 20' BAO< OF F RONT PROPERTY LINE ~ PROPERTY LN: L---- Minimum Square Footing Sizes (inches)1•2 Post Joist Span (in feet) Spacing ~ 4 6 ~J 10 · 12 ' 14 16 1B 4 12 14 16 18 20 20 22 24 6 14 16 20 22 24 24 28 30 ~ ~.,.......,_ ( s') M 20 22 04) 26 28 30 32 -- 10 18 22 24 28 30 32 34 36 12 20 24 28 32 32 36 36 38 1. Assumes 1,000 psf soil bearing capacity 2. The minimum depth for all footings is 12 inches into natural grade B-4 Page 2 of 6 Rev. 03/09 I f B-4 Post Spacing 4 6 (13 10 12 Allowable Joist Sizes ~sts~ Joist Span Joist Spacing Size of glas Redwood Joist 6'3" 6'3" 12" 5'6" 5'6" 16" 2x4 5'0" 5'0" 24" 9'9" 9'9" 12" 8'9" 8'9" 16" 2x6 7'9" 7'9 24" en 12'9" d9 '11 '9" . 2x8 11 '9" 10'2' 10'2" 16'5" 16'5" 12" 15'0" 15'0" 16" 2 X 10 13'0" 13'0" 24" 20'0" 20'0" 12" 18'0" 18'0" 16" 2 X 12 15'10" 15'10" 24" 22'9" 22'6" 12" 19'9" 21 '0" 16" 2 X 14 16'0" 17'0" 24" 1. Assumes a live load of 40 psf and a dead load of 8 psf. 2. If joists are within 18" of grade, use pressure treated Douglas Fir-Larch or Foundation Grade Redwood 3. Assume F(b)=825 psi, F9v)=90 psi, and E=1,200,000 psi for D.F. #2 4. Assume F(b)=925 psi, F9v)=80 psi, and E=1 ,200,000 psi for Redwood Allowable Beam Sizes ' Joist Span (in feet) 4 6 8 10 12 1.4 16 4x4 4 x6 4 x6 4x8 4 X 10 4 X 10 4 X 14 4x6 4x8 4x8 4 X 10 4 X 10 4 X 14 4 X 14 6x8 6x8 6 X 10 6 X 12 4 X 10 4 X 10 4 X 12 4 X 14 4 X 14 4 X 14 4 X 16 6x8 6x8 6 X 10 0,X I I,!)___. 6 X 10 6 X 12 6 X 12 4 X 10 4 X 14 4 X 14 4 X 16 4 X 16 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6 X 14 6 X 14 6 X 14 4x 10 4 X 14 4 X 14 4 X 16 4 X 16 4 X 18 6 X 16 6 X 10 6 X 12 6 X 12 6 x14 6 X 14 6 X 14 Page 3 of 6 Rev. 03/09 B-4 Figure 4/Typical deck elevation looking parallel to rear of dwelling T Greater than 4'-0" l For ledger-to-house comection use two 3/8"0xs• lag bolts at 16" on center maximum for joist spans up to 22'-0" and 32" on center maximum for joists spans up to 11·-0•. Distance from edge of 2x6 minimum ledger to center of bolt 10 be 1112• minimum. Figure 5/Typical pad footing 8" to natural grade from top of footing for isolated pier footings Simpson CB or equivalent Figure &/Typical deck elevation facing rear of dwelling Decking Girder T If greater than 4 •-0• provide braces at post-to-beam connections _i_ ~ 3·-0· maximum ~ Page 4 of 6 42" minimum Use two 112·0xs· bolts through 2x6 joists minimum at 3'-0" maximum on center. Distance from edge of member 10 center of bolt to be 11/i minimum. Rev. 03/09 ' I B-4 Typical deck Min. 18ga. U-type hanger Post-to-girder connection ea .. 1/End a>ndition Post cap inataled per manufac1Ll'er's installation inatnlctions ~24; maxmum,-.i i,,.E1a-minimum Provide 4x4 knee brace or ~to-botmm brac:eonlhe inlllrior side of all post-to-beam oonneetions when post height exceeds 4·-0· ea .. 2/lnterior condition Post cap installed per manufacturer's instalalion instructions 18* minimum)li,j ~~~~ Two 1/2 "0 lag ~--I...--bolts top and ---1...----"!IIJI bottom fypical Page 5 of 6 Rev. 03/09 B-4 Coastal Zone Boundary Legend D 'Mthin Coastal Boundary D Outside Coastal Boundary Costal Commision 7575 Metropolitan Drive Suite 103 San Diego, CA 92108-4402 (619) 767-2370 Page 6 of 6 Rev. 03/09