HomeMy WebLinkAbout1741 Bruce Rd; ; CBR2017-0085; PermitPrint Date: 08/22/2017
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
1741 Bruce Rd
BLDG-Residential
2073604200
$35,533.64
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Residential Permit
www.carlsbadca.gov
Work Class: Alteration Status:
Lot#: Applied:
Reference#: Issued:
Construction Type: Finaled:
Bathrooms: Inspector:
Orig. Plan Check#:
Plan Check#:
Description: PERRY: REMODEL 764 SF BATH AND ADD CLOSET TO EXISTING BEDROOM// DOOR REPLACEMENT
Owner: Contractor:
Permit No: CBR2017-0085
Closed -Finaled
01/12/2017
02/15/2017
MColl
COOWNER PERRY ROBERT C&ROBIN B
1741 Bruce Rd
JACKSON DESIGN AND REMODELING
BUILDING PERMIT FEE $2000+
BUILDING PLAN CHECK FEE (BLDG)
CARLSBAD, CA 92008
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
SB1473 BUILDING STANDARDS FEE
STRONG MOTION-RESIDENTIAL
Total Fees: $647.50 Total Payments To Date: $647.50
4797 Mercury St, B
San Diego, CA 92111-2122
619-442-6125
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
$0.00
$316.40
$221.48
$41.00
$62.00
$2.00
$4.62
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: 0 PLANNING ENGINEERING
City of
Carlsbad
JOB ADDRESS
CT/PROJECT# LOT#
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITE#/SPACE#/UNIT#
# OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s) \ ,
CONSTR. TYPE OCC. GROUP
TV\-tU\Of ~ode,, '=}-(o4 lµ
'Bathroom, Add tloS-Q:..,t -\-o E:-X,S"t\V\C, \)QcA,oom, t~\o\o.l.Q._ dee,
EXISTING USE PROPOSED USE GARAGE (SF)
APPLICANT NAME -r !\. ,1 J_ i t
Primary Contact .. 1 ~ V If l'"'tO n,..e/ l 0
CITY(" .. '1"',,._ , STATE ~o,n ui e i) l
FAX
EMAIL
DESIGN PROFESSIONA
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
STATE UC.#
PATIOS (SF) DECKS (SF)
PROPERTY OWNER
EMAIL
CONTRACTOR BUS. NAME
ADDRES~:;.-q-::,.
CITY(""_ CY't#1
STATE u75 CAr-, ct. ,;z c1· V L.>-1 I' u -
FIREPLACE
YESO
AIR CONDITIONING
NoD YES0No0
FAX
FIRE SPRINKLERS
YES0N00
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)).
Workers' Compensation Declaration: I hereby affirm under penalty of perjury one of the following declarations:
Qi have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the pertormance of the work for which this permit is issued.
l:21,1 have and will maintain workers' co'tensatiJ?n: ~s required by Sect1~n 37_op of_the ~abor Code, for the pertormance~9Jthe w~k for which this permit 1s issued. My workers' compensation ~nsurance c mer and policy
numberare:lnsuranceCo.S;-\:ot t, wmpmSCtnDV\ PolicyNo. "'ID r2C12-=1 ExpirationDate 10 ' Ir
This section need not be completed if the permit is for one hundred dollars ($100) or less. 0 Certificate of Exemption: I certify that in the pertormance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as provi for in Se~706 of the Labor code, interest and attorney's fees.
_g CONTRACTOR SIGNATURE I~~ AGENT
I hereby affirm that I am exempt from Contractor's License Law for the following reason:
D
D
D
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. 0Yes 0No
2. I (have I have not) signed an application for a building permit for the proposed work.
3. I have contracted with the following person (firm) to provide the proposed construction (include name address I phone I contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone I contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
_g PROPERTY OWNER SIGNATURE 0AGENT DATE
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? D Yes D No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D Yes D No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D Yes D No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
I certify that I have read the application and state that the above infonnation is correct and that the infonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANYWAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permitissued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or 'Mlrk authorized by such permit is not commenced l'lithin
180 days from the date of such permit or if the building or'Mlrk orized by ch it is suspende r abandoned at any time after the 'Mlrk is commenc,ed for a period of 180 days (Section 106.4.4 Uniform Building Code).
~ APPLICANT'S SIGNATURE DATE j
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
CERTIF!CATIE OF OCCUPANCY /Commercial P1·ojects 0 n H l' I
Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
I CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE I FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
D PICKUP: o CONTACT (Listed above) o OCCUPANT (Listed above)
o CONTRACTOR (On Pg. 1)
o ASSOCIATED CB#
D MAIL TO: o CONTACT (Listed above) o OCCUPANT (Listed above)
o CONTRACTOR (On Pg. 1) o NO CHANGE IN USE/ NO CONSTRUCTION
D MAIL/ FAX TO OTHER:
o CHANGE OF USE/ NO CONSTRUCTION
.Ji5 APPLICANT'S SIGNATURE DATE
Scheduled
Date
08/11/2017
08/22/2017
August 22, 2017
Alteration
Closed -Finaled
Actual
Start Date Inspection Type Inspection No.
08/11/2017 BLDG-Final 031422-2017
Inspection
Chee id 1st
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
08/22/2017 BLDG-Final 032451-2017
Inspection
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
02/15/2017
01/24/2018
1416
Inspection Status Primary Inspector
Cancelled Paul Burnette
Passed Paul Burnette
CARLSBAD TCT#82-21
1741 Bruce Rd
Carlsbad, CA 92008-4259
Re inspection
Reinspection
No
No
No
No
No
Yes
Yes
Yes
Yes
Yes
Complete
Complete
Complete
Page 2 of 2
Alteration 02/15/2017 CARLSBAD TCT#82-21
Closed -Finaled 01/24/2018 1741 Bruce Rd
Carlsbad, CA 92008-4259
1416
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
04/19/2017 BLDG-16 Insulation 020655-2017 Passed Peter Dreibelbis Complete
Checkiist Item
BLDG-Building Deficiency Yes
03/16/2017 03/15/2017 BLDG-21 016521-2017 Passed Paul York Complete
Underground/Underf
loor Plumbing
Checklist Item Passed
BLDG-Building Deficiency No
04/11/2017 04/11/2017 BLDG-84 Rough 019624-2017 Passed Michael Collins Complete
Combo(14,24,34,44)
Checklist Item COMMENTS
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
04/19/2017 04/19/2017 BLDG-17 Interior 020443-2017 Failed Peter Dreibelbis Reinspection Complete
Lath/Drywall
Cl1ecklist Item COMMENTS Passed
BLDG-Building Deficiency Wrong code, insulation ok No
04/27/2017 04/27/2017 BLDG-17 Interior 021434-2017 Failed Paul Burnette Reinspection Complete
Lath/Drywall
Checklist Passed
BLDG-Building Deficiency Wrong code, insulation ok No
05/02/2017 05/02/2017 BLDG-17 Interior 021737-2017 Passed Paul Burnette Complete
Lath/Drywall
Checklist Item COMMENTS PasstH:1
BLDG-Building Deficiency Wrong code, insulation ok Yes
06/27/2017 06/27/2017 BLDG-18 Exterior 027205-2017 Passed Michael Collins Complete
Lath/Drywall
BLDG-Building Deficiency Yes
07/28/2017 07/28/2017 BLDG-13 Shear 030051-2017 Cancelled Chris Renfro Reinspection Complete
Panels/HD (ok to
wrap)
Passed
BLDG-Building Deficiency No
August 22, 2017 Page 1 of 2
R2017-0085
EsGil Corporation
In (J?artnersliip witli <;;overnment for CBuift{ing Safety
DATE: Feb 10, 2017
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: R2017-0085
PROJECT ADDRESS: 1741 Bruce Rd.
PROJECT NAME: Remodel for Perry Residence
SET: II
D APPLICANT
LO-,J.lJRIS.
D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
~ The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
D The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
D The applicant's copy of the check list has been sent to:
~ EsGil Corporation staff did not advise the applicant that the plan check has been completed.
D EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:......----Telephone#:
Date contacted: --(((j},6) Email:
Mail Telephone Fax In Person
~ REMARKS: Person responsible for plan preparation to cross out note clouded in red on the
cover sheet of the set of plans held at the city to match the plan set being approved.
By: Rich Moreno
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
Feb 6, 2017
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation
In Partnersnip witn qovernment for <.Bui{i:{ing Safety
DATE: Jan 23, 2017
JURISDICTION: City of Carlsbad
PLAN CHECK NO.: R2017-0085
PROJECT ADDRESS: 1741 Bruce Rd.
PROJECT NAME: Remodel for Perry Residence
SET: I
.
r:;i _Ji.PPLICANT
~JURIS.
D PLAN REVIEWER
D FILE
D The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
D The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
D The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
cgj The check list transmitted herewith is for your information. The plans are being held at EsGil
Corporation until corrected plans are submitted for recheck.
D The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
cgj The applicant's copy of the check list has been sent to:
Terry Montello
D EsGil Corporation staff did not advise the applicant that the plan check has been completed.
cgj EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Terry Montello Telephone#: 619-994-5557
Date contacted: f l'23(byyt:_1, Email: Permits@cox.net ~--..
~Mail ..,/Telephone Fax In Person
D REMARKS:
By: Richard Moreno
EsGil Corporation
D GA D EJ D MB D PC
Enclosures:
Jan 17, 2017
9320 Chesapeake Drive, Suite 208 + San Diego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
PLAN REVIEW CORRECTION LIST
SINGLE FAMILY DWELLINGS AND DUPLEXES
PLAN CHECK NO.: R2017-0085
PROJECT ADDRESS: 1741 Bruce Rd.
FLOOR AREA: Remodel: 764 sq-ft
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: Jan 11, 2017
DATE INITIAL PLAN REVIEW
COMPLETED: Jan 23, 2017
FOREWORD (PLEASE READ):
JURISDICTION: City of Carlsbad
STORIES: n/ a
HEIGHT: no change
DATE PLANS RECEIVED BY
ESGIL CORPORATION: Jan 17, 2017
PLAN REVIEWER: Richard Moreno
This plan review is limited to the technical requirements contained in the California version of
the International Residential Code, International Building Code, Uniform Plumbing Code,
Uniform Mechanical Code, National Electrical Code and state laws regulating energy
conseNation, noise attenuation and access for the disabled. This plan review is based on
regulations enforced by the Building Department. You may have other corrections based on
laws and ordinance by the Planning Department, Engineering Department, Fire Department or
other departments. Clearance from those departments may be required prior to the issuance of
a building permit.
Present California law mandates that construction comply with the 2013 edition of the California
Code of Regulations (Title 24), which adopts the following model codes: 2012 IRC, 2012 IBC,
2012 UPC, 2012 UMC and 2011 NEC.
The above regulations apply, regardless of the code editions adopted by ordinance.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
• PLANS
1. Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring TWO corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed by the City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
2. All sheets of plans must be signed by the person responsible for their
preparation. (California Business and Professions Code).
3. Please submit a complete set of plans. Architectural, electrical, structural, etc.
4. Provide a statement on the Title Sheet of the plans stating that this project shall
comply with the 2016 California Residential Code, which adopts the 2015 IRC,
2015 UMC, 2015 UPC and the 2014 NEC. Section R106.1.
5. Provide a fully dimensioned site plan drawn to scale. Section R106.2. Please
include the following:
a) North arrow.
b) Property lines/easements.
c) Streets/alleys.
d) Existing and proposed buildings and structures.
• FIRE PROTECTION
6. Show locations of permanently wired smoke alarms with battery backup, per
Section R314:
a) Inside each bedroom.
b) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
c) On each story, including basements.
d) Such smoke alarm locations shall comply with the following:
i) They shall be not less than 3' from the door opening of a bathroom.
CONTINUED
ii) They shall be at least 20' from a cooking appliance.
iii) They shall be at least 3' from supply registers of heating/cooling
systems.
iv) They shall be at least 3' from the tip of the blade of a ceiling-
mounted fan.
• NOTE: When more than one smoke alarm is required to be installed, the
alarm devices shall be interconnected in such a manner that the actuation of
one alarm will activate all of the alarms in the unit.
7. In existing buildings, when alterations, repairs or additions requiring a permit
occur (or when one or more sleeping rooms are added), the dwelling unit shall
be provided with smoke alarms located as required for new dwellings; the
smoke alarms shall be interconnected and hard wired. Exception: Smoke alarms
in existing areas need not be interconnected and hard wired where the
alterations or repairs do not result in the removal of interior wall or ceiling finishes
exposing the structure, unless there is an attic, crawl space, or basement
available which could provide access for hard wiring and interconnection without
the removal of interior finishes. Section R314.8.1.
8. In dwelling units within which fuel-burning appliances are installed (and in
dwelling units having attached garages), show the locations of permanently wired
carbon monoxide alarms with battery backup, per Section R315:
a) Outside each separate sleeping area in the immediate vicinity of the
bedrooms.
b) On each story, including basements.
• NOTE: When more than one carbon monoxide alarm is required to be
installed, the alarm devices shall be interconnected in such a manner that the
actuation of one alarm will activate all of the alarms in the unit.
9. When alterations, repairs or additions are proposed for dwelling units within
which fuel-burning appliances are installed (and in dwelling units having attached
garages), the dwelling unit shall be provided with carbon monoxide alarms
located as required for new dwellings; the carbon monoxide alarms shall be
interconnected and hard wired. Exception: Carbon monoxide alarms in existing
areas need not be interconnected and hard wired where the alterations or repairs
do not result in the removal of interior wall or ceiling finishes exposing the
structure, unless there is an attic, crawl space, or basement available which
could provide access for hard wiring and interconnection without the removal of
interior finishes. Section R315.2.
• FRAMING
10. Show stud size, height and spacing on the plans. Maximum allowable stud
heights shall be per Table R602.3(5).
11 . Are all wall portions being removed non-load bearing walls? Please provide a
non-load bearing top connection if so, or a load bearing and blocking detail if
load bearing.
• ELECTRICAL
12. Show on the plans a wall receptacle within 36" of each lavatory in the bathroom.
CEC 210.52(0).
13. Show on the plans that countertop receptacle outlets comply with CEC Article
210.52(C): In kitchens a receptacle outlet shall be installed at each counter
space 12 inches or wider; Receptacles shall be installed so that no point along
the wall line is more than 24 inches; Island and peninsular countertops 12 inches
by 24" long (or greater) shall have at least one receptacle. (Counter top spaces
separated by range tops, refrigerators, or sinks shall be considered as separate
counter top spaces).
14. Per CEC Article 210.11 (C)3, note on the plans that bathroom circuiting shall be
either:
a) A 20 ampere circuit dedicated to each bathroom, or
b) At least one 20 ampere circuit supplying only bathroom receptacle outlets.
• ENERGY CONSERVATION
15. Replacement of existing fenestration up to 75 sq. /ft. only needs to meet the U-
factor of .40 and SHGC of .35 specifications, not the Table 150.1-A specification
values. "Replacement" windows are windows replaced in the same wall with the
same total fenestration area per wall as the existing.
• MISCELLANEOUS
16. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
17. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
• Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes D No D
18. The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Richard Moreno at
EsGil Corporation. Thank you.
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: City of Carlsbad PLAN CHECK NO.: R2017-0085
PREPARED BY: Richard Moreno
BUILDING ADDRESS: 1741 Bruce Rd.
BUILDING OCCUPANCY: R-3/U
BUILDING
PORTION
Remodel
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb
Bldg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review:
D Repetitive Fee
.., Repeats
Comments:
AREA Valuation
( Sq. Ft.) Multiplier
764 citv est.
By Ordinance
Complete Review
D Other
D Hourly
EsGil Fee
DATE: Jan 23, 2017
Reg. VALUE ($)
Mod.
35,534
35,534
$316.891
$205.981
D Structural Only
t-----------11 Hr @ '
$177.461
Sheet 1 of 1
macvalue.doc +