Loading...
HomeMy WebLinkAbout1744 CEREUS CT; ; CB140266; Permit02-03-2014 City of Carlsbad 1635 Faraday Av Carlsbad, OA 92008 Plumbing/Mechanical/Electrical (PME) Permit Permit No:CB140266 Building Inspection Request Line (760) 602-2725 Job Address Permit Type Parcel No Reference # PC# Project Title 1744 CEREUS CT CBAD PME 2155170400 Lot# POYRESS UPGRADE SERVICE TO 125AMPS Status Applied Entered By Plan Approved Issued Inspect Area ISSUED 02/03/2014 JMA 02/03/2014 02/03/2014 Applicant RACEWAY ELECRIC Owner POYTRESS PO BOX 710885 92072 619-596-1918 92024 Plumbing Fees Electrical Fees Mechanical Fees Other PME Fees $0 00 $158 00 $0 00 $0 00 TOTAL PERMIT FEES $158 00 Total Fees $158 00 Total Payments To Date $158 00 Balance Due: $0.00 Inspector INALAPPROVAL Date l'U3i Clearance NOTICE Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the Crty Manager for processing in accordance wrth Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your nght to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees m connection with this project NOR DOES IT APPLY to any fees/exactions of which vou have previously been given a NOTICE similar to this, or as to which the statute of limitations has oreviouslv otherwise expired ; THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE. OPLANNING OENGINEERING nBUILDING ORRE •HEALTH QHAZMAT/APCO ^ CITY OF CARLSBAD Building Permit Application 1635 Faraday Ave , Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 email building@Garlsbadca gov www.carlsbadca.gov Plan Check No. Est. Value Plan Ck. Deposit Date k. pepjpsit JOB ADDRESS 7k SUITE#/SPACE#/UNIT# PHASE # # OF UNITS # BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR TYPE OCC GROUP DESCRIPTION OF WORK' /nc/ude Square Feet of Affected Area(s) ^6^t^ye/if^^ ^^^c^/c?^ c7^(^y/^<dP^ 72> /9'^^y ^^a^f^ /i7<^/7-'^^ EXISTING USE PROPOSED USE GARAGE (SF) PATIOS (SF) DECKS (SF) FIREPLACE YESQ# Noj I AIR CONDITIONING YES I INO I I FIRE SPRINKLERS YES I |NO| I APPLICANT NAIVIE (Pf7/nary Co()tact; y APPLICANT NAME (Secondary Contact) ADDRESS ADDRESS CITY STATE ZIP CITY STATE ZIP PHONE FAX PHONE FAX P^<^^y/73<£. (7%/ .x/-^ EMAIL PROPERTY OWNER NAME A7/77r /"^ :ONTRACTgaSUS. NAME ADDRESS )S ' STATE ZIP CITY -^^^^g'^ <3/^ STATE ZIP PHONE_ FAX PHONE ,^ FAX ^7^^ iS?Pi^ -79/^ EMAIL EMAIL ^ CTATC I 3 I m ACC I f\T\J Dl It ARCH/DESIGNER NAME & ADDRESS CITY BUS LIC# V.-7^ V (7rt>p{7^<^ (Sec 70315 Business and Professions Code Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, pnor to its issuanqfe, sflso requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section •?00D of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption Any violation of Section 70315 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500}) Workers' Compensation Declaration / herefcy affirm under penalty ofpeijury one of the following declarations C 1 have and will maintain a certificate of consent to self-Insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this perniit is issued \3 I have and will maintain workers' compensation, as required tiy Section 3700 of the Labor Code, for the performance of the work for which this permit is issued My workers' compensation insurance carrier and policy numberare InsuranceCo Policy No Expiration Date yhiytectinn need not be completed if the permit is for one hundred dollars ($100) or less l/Sf ertificate of Exemption. I certify that in the performanceof the work for which this pemiit is issued, 1 shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of Caiifomia WARNING' Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to cnminal penalties and civil fines up to one hundred thousand dollars (SIOO.OOO), in addition to the cost of compensation, damages as prwFBSittpr in Section 3706 of ti^fl&bor code, interest and attomey's fees. JS^ CONTRACTOR SIGNATURE • AGENT DATE ..^^^y^^ I tiereby affm that I am exempt from Contractor's Ucense Law for the following reason I I 1, as owner of the property or my employees with wages as their sole compensation, will do the work and the stnicture is not intended or offered for sale (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale If, however, the building or improvement is sold withm one year of completion, the owner-builder will have the burden of proving that he did not build or improve tor Ihe purpose of sale) I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7044, Business and Professions Code The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and conlracts for such projects with contractor(s) licensed pursuant to the Contractor's Ucense Law) • • am exempi under Section _ .Business and Professions Code for this reason 1 I personally plan to provide the major labor and matenals for construction of the proposed property improvement QYes I INO 2 I (have / have not) signed an application for a building pemiit for the proposed work 3 I have contracted with the following person (fimn) to provide the proposed construction (include name address / phone / contractors' license number) 4 I plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the major work (include name / address / phone / contractors' license number) 5 I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) y^TpROPERTY OWNER SIGNATURE •AGENT DATE Is the applicant or future building occupant required to submit a business plan, acutely hazardous matenals registration form or nsk management and prevention program under Sections 25505,25533 or 25534 of the Presley-Tanner Hazardous Substance Account AcP , Yes ' • No is the applicant or future building occupant required to obtain a permit from the air pollution control distnct or air quality management distncr? .' Yes -f- No Is the facility to be constnjcted within 1,000 feet of Ihe outer boundary of a school site'? Yes ' No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a consfruchon lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name ; Lender's Address I certifythati have read the application and state that theaboveinfomiatonis conect and that the infonnation on the plans is accuiate. I agme to comply with all City oidinances and State laws relating to building conshiiction. I hereby authonze representative ofthe City of Cartsbad to enter upon the above mentoned property for inspection purposes I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST Aa LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA pennit is required for excavatons over 5'0' deep and demolition or constmction of stmctures over 3 stones in height EXPIRATION Every pemnit issued by the Building Ofliaal under the provisions of this Code shall expire by limitaton and become null and void t the building or work authorized by such perniit is not commenced within 180 days fom the date of such perniit or if the building^wdiauthonzed by such pemnit is suspended or abandoned at any time after the work is commenced for a penod of 180 days (Section 106 4 4 Unifomi Building Code) APPLICANT'S SIGNATURE DATE STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE. Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection. OCCOPAiyCY ICommerc Fax (760) 602-8560, Email buildinQ(5)carlsbadca gov or Mail the completed form to City of Carisbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008 C0#: (Office Use Only) CONTACT NAME OCCUPANT NAME ADDRESS BUILDING ADDRESS CITY STATE ZIP CITY STATE ZIP Carlsbad CA PHONE FAX OCCUPANT'S BUS LIC No DELIVERY OPTIONS "'PICKUP: - CONTACT (Listed above) S^i OCCUPANT (Listed above) CONTRACTOR (On Pg 1) , MAIL TO: ' CONTACT (Listed above) , * OCCUPANT (Usted above) , CONTRACTOR (On Pg 1) , MAIL / FAX TO OTHER: ASSOCIATED CB#- NO CHANGE IN USE / NO CONSTRUCTION ; CHANGE OF USE / NO CONSTRUCTION ^APPLICANT'S SIGNATURE DATE Inspection List Permit*: CB140266 Type: PME POYRESS: UPGRADE SERVICE TO 125AMPS Date Inspection Item Inspector Act Comments 02/19/2014 33 Service Change/Upgrade - Rl 02/18/2014 33 Service Change/Upgrade PB AP Thursday, February 20, 2014 Page 1 of 1 SDGl A Sempra Energy uiiniy'- WantedDate ON INSPECTION ELECTRIC UNDERGROUND METER & SERVICE LOCATION Customer Copy Service Type UG Rewire (no trenching) Proiect No 451056 Job No 010 Propd Trtle POYTRESS RESIDENCE (SOT) Project Address 1744 CEREUS CT ProieclCily CARLSBAD Contact EDDIE DOMBO Customer Phone # Contact Phone # 619-596-1918 D Traffic Control Permit Required Excavation/Encroachment Permits Required By Customer Service Attachmeni Point and/or Meter Location Install new 125-amp meter panel at existing location over existing conduit and service conductors. Customer assumes responsibility for existing SIDA condition. If SIDA conductors cannot be reconnected for any reason, customer js advised they will not be reconnected until they can trench and replace the SIDA conductors with 2-inch conduit from the panel to the source. Call SDG&E Service Coordinator Wendy at 760-476- 5611 to schedule a morning disconnect with an afternoon reconnect provided that the City/County releases inspection to SDG&E by 2:00 PM on tiie same day the crew is scheduled. To avoid delays with reconnection, your permit should read (Customer Outage Involved). ^ SDG&E Application Required-Call 1-800-411-7343 Municipal Inspection Required By City Of Carlsbad Meter height - W imn (JO" mm for miltple meter installation) - 63' max From finish grade to centeiline of meter base Meters are requited to be readly accessible 24 hours per day Meleis must be located in a safe area tree of any potentially hazardous or dangerous condition Proinde 3-ft X 3-tt Minimum dear and level working space in fronI of meter V^here meter nxim is proposed, contact the planner at Ihe nearest SDG&E office Meter bases and meter service dsconnects must be located at or immediately adjacent to each other and be identified wth address and umtnuntier rt senses ^^^^^ PROCEDURE FOR INSTALLATION 1 PHONE DIG ALERT 1-800-227-2600 AT LEAST TWO DAYS PRIOR TO TRENCHING FOR LOCATION OF UNDERGROUND UTIUTIES 2 Phone SDG&E at 760-476-5611 for the following • 3 working days prior to trenching to anange pre-meet with inspector and initiate trenching process • After excavation of trench, installation of condurt and service entrance equipment al meter location, CALL FOR INSPECTION Do not cover condurt without inspector's written approval to backhll . When trench is backfilled and compacted, CALL FOR INSPECTION If service entrance equipment is installed after backfill, CALL FOR INSPECTION OF THE EQUIPMENT 3 Meter cannot be set until inspector has approved installation, including service equipment, and receipt of citY/county/state inspection clearance Power Source 1116-655 Structure Number EXISTING 3312 HANDHOLE Joint Trench with Handhole Installed by Standards Page Handhole Lid Shall Read Conduit Installed by Condurt Size Service Panel Rating 125 Number/Size of Mam Swrtch 1/125 Voltage 120/240 #o) Wires 3 Phase Single Utilities Maximum Contribution to Fault Current 10000 Amps Metenng Self-Contained Meter Clips 4 Temp Service Charge Due on First Bill $ T.B. 1127-E6 N Customer Type Residential Date Prepared 01/29/2014 DISCOMKECT^ECONNECT PROJECTS 451056 XST- COLUMBINE Additional Information • Right-of-wray Required Assessor's Parcel Number Please call your Service Coordinator Wendy Jensen at 760-476-5611 with questions about application, inspection, construction installation and to schedule a crew. City/County inspection will have to be received prior to 2:00 p.m. on the same day as the disconnect to allow SDG&E crew enough time for reconnection of service on the same day If SDG&E encourters hazanlous or toxic matenal while peribnning construction of your project SDGSE wll halt wortt immediately aid it will be your responsibilrty to remove and/or clean up all haz^ous or toxic matenal pnor to SDG&E continuing construction SDG&E shall have no liability or obligation Vftiatsoeverto dewi up remove or remeciale anjr hazardous a toxic materials discovered dunng the course of construction uriess it is thnjugh negligence ol SDG&E Customer-owned laalrties to recave electncal service are subject to all applicable local and state of California inspection authonty requirernents Building address andlor meter base must be posted pnor to meter set Infonnation on this sheel is void after six (6) months from date Keep this notice with bulding pcimit All installations perfonned under Ihis onler must meet SDG&E standards unless a wntten deviaion has been appioved Planner AMY P MCBROOM Telephone 760-476-5610