Loading...
HomeMy WebLinkAbout1749 CHESTNUT AVE; ; CB920525; Permit<• m BUILDING PERMIT 06^/17/92 13:35 Page 1 of 1 Job Address: 1749 CHESTNUT AV Suite: Permit Type: RESIDENTAL ADD/ALT Parcel No: 205-230-01-00 Lot#: Valuation: 7,007 Construction Type: VN Occupancy Group: R3 Reference*: Description: 100 SF BATHROOM REMODEL/ADD. Permit No Project No Development No CB920525 A9201358 8112 06/17/92 0001 01 C-PRMT 02 144-00 Appl/Ownr : GATES,STEVEN 5248 ROBINWOOD DRIVE OCEANSIDE CA 92056 *** Fees Required *** s Status: ISSUED Applied: 05/28/92 Apr/Issue: 06/17/92 Validated By: MDP 619 758-3372 Fees Collected & Credits *** Fees: 208.00 Adjustments: .00 Total Fees: , 208.00 Fee description Building Permit Plan Check Strong Motion Fee * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Building Sewer > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Enter "Y" for Remodel > * ELECTRICAL TOTAL Total Credits: Total Payments: Balance Due ; Units - Fee/Unit - 0 :• . ' o - . 0 ' ' 0 0 4 2. SO 1 6 ,50 0 0 0 0 '54. 144. Ext f e 99. 64. 1. 164. 7 . 10. 6. 24 , 10 . 10 . 20. 00 00 00 e 00 00 00 00 50 00 50 00 00 00 00 Data Y Y Y CITY OF CARLSBAD 2075 Las Palmas Dr., Carlsbad, CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr., Carlsbad. CA 92009 (619) 438-1161 T7TERM11 A - U Commercial U New Building U Tenant Improvement B - D Industrial D New Building D Tenant Improvement C vB&esidential D Apartment DCondo D Single Family Dwelling ^[Addition/Alteration D Duplex D Demolition D Relocation D Mobile Home D Electrical D Plumbing D Mechanical D Pool D Spa D Retaining Wall D Solar D Other 2. PROJECT INFORMATION PLAN CHECK NO. oooi 01 C-PRMT 64-00 FOR OFFICE USE ONLY Building or Suite No.Address Nearest Cross Street LEGAL DESCRIPTION Lot No. Subdivision Name/Number Unit N Phase No. CHECK BELOW IF tSUBMlTl'tlD: D 2 Energy Calcs C3 2 Structural Calcs Q 2 Soils Report D1 Addressed Envelope ASSESSOR'S PARCEL EXISTING USE PROPOSED USE DESCRIPTION OF WORK SQ.FT.# OF STORIES / 3. UJNIAC,! NAME CITY Js3JO (it ditterent rrom applicant; STATE ADDRESS ZIP CODE DAY TELEPHONE 4.NTHA(JTUK NAME CITY UACihNl rUK CUN1RAL.IOK ADDRESS LJUWNhR UAOtNi rOK UWNhK STATE'ZIP CODE DAY TELEPHONE 5. NAME CITY OWNJilJ C.0TWU STATE ADDRESS ZIP DAY TELEPHONE 6. GONTRAC IORNAME CITY At -V <£. ADDRESS STATE ZIP CODE STATE LIC. # 3ST}009 LICENSE CLASS . UEMONhH NAMfc CITY STATE ZIP CODE DAY TELEPHONE CITY BUSINESS LIC. # DAY TELEPHONE STATE LIC. # COMPENSATION Workers Compensation Declaration: I hereby affirm that I have a certificate or consent to self-insure issued by the Director or Industrial Relations, or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800, Lab. C). INSURANCE COMPANY ^TUTjfr'••Cufc/P POLICY NO. i^tV^QZ.-^ I EXPIRATION DATE £t/& «? 2. Certificate ot Exemption: l certify that in the performance of the work tor which this permit is issued, l shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California. SIGNATURE DATE 8. OWNER-BUILDER DECLARATION Owner-Builder Declaration: I hereby affirm that f am exempt from the Contractors License Law tor the following reason: D I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale.). D I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law). D I am exempt under Section Business and Professions Code for this reason: (Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish, or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and Professions Code) or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars [$500]). SIGNATURE DATE COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? D YES D NO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? D YES D NO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? D YES D NO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED AFTER JULY 1. 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. 9. CUNSTKUCJIION LliNDING AGKNCJY 1 Hereby affirm that there is a construction lending agency tor the performance ot the work tor whicn this permit is issued (Sec 30V"/ uj Civil (JodeJ. LENDER'S NAME LENDER'S ADDRESS 10. APPL1CAN1 1 certify tnat 1 nave read tne application ana state tnat the above information is correct. I agree to comply with all (Jity ordinances and State laws relating to building construction. I hereby authorize representatives of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SATO CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT. OSHA: An OSHA permit is required for excavations over S'O" deep and demolition or construction of structures over 3 stories in height. Expiration. Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 365 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code). APPLICANTS SIGNATURE DATE: WHITE: FOe YELLOW: Applicant PINK: Finance.^ I ' .] I • / g.- CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB920525 FOR 03/09/93 DESCRIPTION: 100 SF BATHROOM REMODEL/ADD. TYPE: RAD JOB ADDRESS: 1749 CHESTNUT AV APPLICANT: GATES,STEVEN CONTRACTOR: OWNER: REMARKS: MH/STEVEN/758-3372 SPECIAL INSTRUCT: PHONE: PHONE: PHONE: INSPECTOR AREA MP PLANCKtf CB920525 OCC GRP R3 CONSTR. TYPE VN STE: LOT: 619 758-3372 INSPECTOR TOTAL TIME: CD LVL DESCRIPTION 19 29 39 49 ACT COMMENTS ST Final PL Final EL Final ME Final Structural & Plumbing Electrical i Mechanical Y ***** INSPECTION HISTORY ***** DATE DESCRIPTION 102992 Interior Lath/Drywall 100592 Insulation 092292 Roof/Reroof 092292 Frame/Steel/Bolting/Welding 092292 Rough/Topout 092292 Rough Electric 082492 Frame/Steel/Bolting/Welding 081392 Footing 081192 Footing 080692 Ftg/Foundation/Piers ACT AP AP AP AP AP AP PA AP NR AP INSP MP MP PY PY PY PY MP PK PK MP COMMENTS ND A 35 @ BLOCKS TO TOP PLT UTL/NO ADDRESS ON HOUSE ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619)560-1468 DATE:QAPPJJjC • JURISDICTION: PLAN CHECK NO:SET: PROJECT ADDRESS; PROJECT NAME: JPLAN CHECKER [jFILE COPY QUPS PIDESIGNER D The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified ""Sv^L-oo) are resolved and D D D checked by building department staff. IThe plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. i The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. [~"| The applicant's copy of the check list has been sent to; Esgil staff did not advise the applicant contact person that plan check has been completed. Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: REMARKS; Telephone f Enclosures ESGIL CORPORATION DGA DCM x: ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 560-1468 DATE: CARLSBADJURISDICTION: PLAN CHECK NO: PROJECT ADDRESS: PROJECT NAME: "5Wm SET: QT l APPLICANT R r[PLAN CHECKER QFILE COPY QUPS HDESIGNER The plans transmitted herewith have been'Corrected where necessary and substantially comply with the jurisdiction's building codes.i The plans transmitted herewith will substantially comply with the jurisdiction's-building codes when minor deficien- cies identified are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. | The applicant's copy of the check list has been sent to: j^H Esgil staff did not advise the applicant contact person that ^ plan check has been completed^ QTVVtgg. TPrR-NJ. mrt >i_>(4<W I1 Esgil staff did advise applicant that the plan check has been completed. Person contacted: Date contacted: REMARKS: Telephone #_ & HiArO ESGIL CORPORATION Enclosures DGA DCM PLAN CHECK NO:FOREWORD: PLEASE REAP JURISDICTION: CITY OF CARLSBAD ENCLOSURES: PROJECT ADDRESS: FLOOR AREA: STORIES: HEIGHT: REMARKS: ' PLAN CORRECTION SHEET CITY OF CARLSBAD SINGLE FAMILY AND DUPLEX DWELLINGS Date plans received by jurisdiction: Date plans ireceived by Esgil Corporation: Date initial plan check completed: BV= Applicant contact person: :£v=Fn=Sreleohone; 1 5ft ' Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances by the Planning Department, Engineering Department or other departments. Present California law mandates that residential construction comply with Title 24 and the following model codes: 1988 UBC (eff. 1/1/90) 1988 UPC (eff. 1/1/90) 1990 NEC (eff. 7/1/91) 1988 UMC (eff. 1/1/90) The above regulations construction, regardless adopted by ordinance. apply to residential of the code editions The circled items listed need clarification, modification or change. All items have to be satisfied before the plans will be in conformance with the cited codes and regulations. Per Sec. 303(c), 1988 Uniform Building Code, the approval of the plans does not permit the violation of any state, county or city law. o speed up the recheck process. note on this lis for a coovl where each correction item has been specification when vou submit NOTE: (PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. List No. 12, Carlsbad Single Family Dwelling and Duplex With All Supplements. (1988 UBC) PLANS Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, California 92123, (619) 560-1468. Please nake all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The-jurisdiction's building department. Indicate on the Title Sheet of the plans, the namo—e£—tho lagal—owner—asd- name of person responsible for the preparation of the plans. 'Section 302(a)7. All sheets of plans must be signed by the person 'responsible for their preparation. (California Business and Professions Code). Plans, specifications and calculations shall be signed by the California state licensed engineer or architect responsible for their preparation, for plans deviating from conventional wood frame construction. Specify expiration date of license. (California Business and Professions Code). Specify on the Title Sheet of the plans the gross floor area of each element of this project including dwelling, garage, carport, patio, deck and balcony. Section 302(d). Provide a stateraent on the Title Sheet of the plans that this project shall comply with Title 24 and 1988 UBC, UMC and UPC and 1990 NEC. Submit fully dimensioned plot plan drawn to scale showing location, size, and use of all existing and proposed structures on the lot. Identify property lines and show lot dimensions and all easements. Show location of all cut or fill slopes. Show finish floor elevations and show elevations of adjacent finish grade. Show drainage patterns with minimum slopes. Section 302(d). -..-.' Indicate distance from property proposed building. Section 302(d). lines to Show on the title sheet all structures, pools, vails, etc. included under this application. Any portion of the project shown on the site plan that is not included with the building permit application filed should be clearly identified as "not included." Clearly show if the lower level is a basement or a story, based on the definitions in Sections 403 and 420. Plot the finish grade (as defined) on the elevations and dimension the distance to the floor above, for story determination. On the cover sheet of the plans, specify any items requiring special inspection, in a format similar to that shown below or sticky back. REQUIRED SPECIAL INSPECTIONS In addition to the regular inspections, the following checked items will also require Special Inspection in accordance with Sec. 306 of the Uniform Building Code. ITEM REQ. IF CHECKED REMARKS SOILS COMPLIANCE PRIOR TO FOUNDATION INSP. STRUCTURAL CONCRETE OVER 2500 PSI PRESTRESSED STEEL FIELD WELDING HIGH STRENGTH BOLTS EXPANSION ANCHORS SPECIAL MASONRY SPRAYED ON FIRE PROOFING PILES/CAISSONS DESIGNER-SPECIFIED OTHER FIRE PROTECTION Exterior walls closer than 3 feet to property lines shall be one-hour rated.construction and have no openings. Table 5-A. C "SHcXX-D Q=~ 7/9/91 Provide spiral 3306 (f): stairway details, per Section b. Minimum run is 7 1/2 inches measured at a point 12 inches from where the treads are the narrowest. Maximum rise is 9 1/2 inches. Maximum clear opening between risers is 6 inches. c. Minimum headroom is 6 feet 8 inches d. The tread must provide a clear walking area measuring at least 26 inches from the outer edge of the supporting column to the inner edge of the handrail. Spiral stairways' may not .be used for required exits when the area served is greater than 400 sq. ft. Section 3306 (f). Provide I.C.B.O. Research Report and number for metal stairway, or submit plans and calculations and approved fabricator registered with the building department or note that the stairway fabrication plans shall be submitted to and approved by the building official prior to installation. Exterior stairways shall not project into the 3 foot setback from the property lines. Section 3306 (n). The walls and soffits of the enclosed usable space under interior stairs shall be protected on the enclosed side as required for one-hour fire-resistive construction. Section 3306 (m). Within units, show that minimum width of 36 inches. ROOFCTG corridors have a Section 3305 (b) . Specify roof slope. Roof slope is not adequate for roof type specified. Table 32-B,C,D and E. Specify roof material and application. Chapter 32. Specify I.C.B.O. or U.L. approval number for roof materials not covered in U.B.C., e.g., tile, etc.' Section 107. Specify minimum 1/4 inch per foot roof slope for drainage or design to support accumulated water. Section 3207 (a) and Section 2305 (f). Show roof drains and overflows. Section 3207. Provide skylight details to show compliance with Sections 3401 and 5207 or provide I.C.B.O. approval number. v ->—^—- Plastic skylights must be separated from each other by at least 4 feet. Section 5207 (a) 6. Show attic ventilation. Minimum vent area is 1/150 of attic area or 1/300 of attic area if at least 50% of the required vent is at least 3 feet above eave vents or cornice vents. Show required area and area provided. Section 3205 (c). MASONRY Provide fireplace construction details or note construction to be per attached fireplace standard drawing. Chapter 37. Show anchored veneer support and connections attached to wood in Seismic Zones 3 and 4, comply with Section 3006 (d)l and Section 2515 (a). Show ties and #9 wire in horizontal joints. Show height and construction details of all masonry walls. Chapter 24. Show floor and roof connections to masonry walls. Connection shall resist 200 pounds per lineal foot or the actual design load, whichever is greater. Cross grain tension or bending in wood ledgers is not permitted. Section 2310. Show a minimum 2" air space and flashing between planter and building walls. Section 2516 (c) 7. GARAGE AND CARPORTS Garage requires one-hour fire protection on the garage side of walls and ceiling common to the dwelling. Table 5-B, Section 503 (d). All elements supporting floor above garage, including walls supporting floor joists, must have one-hour fire-resistive protection on the garage side. Section 503 (b) Show 1 3/8" solid core self-closing door for openings between garage and dwelling. Section 503 (d). Garages are not permitted to open into a room used for sleeping purposes. Section 1104. 12/18/90 7 X 78. 79. 80. An occupancy separation is not required between carport and residence, provided the carport is open ,on two or more sides and has no enclosed uses above. Section 503 (a) Exception 3. Show- garage framing sections, size of header over garage opening, lateral cross bracing at plate line, method bracing garage front and holddowns if required. Chapter 23. NOTE: Maximum shear panel height-to-width ratio is 3 1/2 to 1 for plywood. Table 25-1. Doors may open into the garage only if the floor or landing in the garage is not more than one inch lower than the door threshold. Section 3304 (i). Provide an 18" raised platform for any FAU, water heater, or other device in the garage which may generate a flame or spark. UMC Section 508, UPC Section 1310 (a). FOONDATIOK REOUIREMEKTS Per poils report, note on the plan the soils classification, whether or not the soil is expahsive and note the allowable bearing value. Section 2905 (c). The ; foundation plan does not comply with the soils report recommendations for this project. Please review the report and modify design, notes and details as required to show compliance: Proyide notes on the foundation plan listing the soils report recommendation for foundations, slab and building pad preparation. 81. Proyide a letter from the soils engineer confirming that the foundation plan, grading plan and specifications have been reviewed and that it has been determined that the recommendations in the soils report are properly incorporated into the construction documents (when required by the soil report). 82. The soils engineer recommended that he/she review the foundation excavations. Note on the foundation plan that "Prior to the contractor requesting a Building Department foundation inspection, the soils engineer shall advise the building official in writing that: 1. The building pad was prepared in accordance with the soils report, 2. The utility trenches have been properly backfilled and compacted, and 3. The foundation excavations comply with the intent of the soils report". Show height of all foundation walls. Chapter 23. Show height of foundation walls. retained earth Chapter 23. on all 85. If cut or fill slopes exist, show distance of foundation to edge of cut or fill slopes and show steepness and heights of cuts and fills. Chapter 29. 86. Note on plans that wood shall be 6" minimum above finish grade. Section 2907 (a). 87. Note on plans that surface water will drain away from building and show drainage pattern and key elevations. Section 2905 (f). Dimension foundation per U.B.C. Table 29A: '"'Foundations may support a roof in addition to the floors. Where only a roof is supported, use foundation for one floor. Show foundation sills to be pressure treated, or equal. Section 2516 (c) 3. Show foundation bolt size and spacing. Section 2907 (f). Specify size, I.C.B.O. number and manufacturer of power driven pins. Show edge and end distances and spacing. Section 302 (d). 2/13/90 If required, show size, embedment and location of hold • down anchors on foundation plan. Section 302 (d). If hold downs are required, note on plan that hold down anchors must be tied in place prior to foundation inspection. Section 305 (e) 1. Show adequate footings under all bearing walls and shear1 vails. Section 2907 (b). Show on the plans stepped footings for slopes steeper than 1:10. Section 2907 (c). Show minimum 18" clearance from grade to bottom of ..floor joists and minimum 12" clearance to bottom of girders. Section 2516 (c) 2. Show pier size, spacing undisturbed soil. Table 29 ng an-A-rd depth into Show minimum underfloor access of 18" x 24". Section 2516 (c). Show minimum underfloor ventilation equal to 1 sq. ft. for each 150 sq. ft. of underfloor area. Openings shall be as close to corners as practicable and shall provide cross ventilation on at least two approximately opposite sides. Section 2516 (c) 6.i FRAMING Show wall bracing. Every exterior wood stud wall and main cross-stud partition shall be braced at each end at least every 25 feet of length with 1x4 diagonal let-in braces or equivalent. Section 2517 (g) 3, Table 25-V. In 2-story buildings, shear panels at the first story (at least 48 inches in width) shall be located ; at each end or as near thereto as possible; and comprise at least 25 percent of the linear length of the wall, or provide design. ' Section 2517(g)3, Table 25-V. Note cross bridging or blocking. Floor joists and rafters 12" or more in depth shall be supported laterally by bridging at intervals not exceeding 8 feet, unless both edges are held inline. Sec. 2506 (h), 2517 (d) 6. , Show blocking at ends and at supports of floor joists, rafters and trusses at exterior walls. Section 2517 (d) 3, 2517 (h) 6. . Bearing > partitions, perpendicular to joists, shall not be offset from supporting girders, beams, walls or partitions, more than the depth of the joist. Section 2517 (d) 5. Show rafter ties. Rafter ties shall be spaced not more than 4 feet on center and be just above the ceiling joists, where rafters and ceiling joists are not parallel. Section 2517 (h) 4. Show rafter purlin braces to be not less than 45 degrees to the horizontal. Section 2517 (h) 5. Show double top plate with minimum 48" lap splice. Section 2517 (g) 2. Show nailing 25-Q. will be in compliance with Table \<yf. Show or note fire stops at the following / locations per Section 2516 (f):/ a. In concealed spaces of stud walls and partitions, including furred spaces, at the ceiling and floor levels and at 10 foot intervals along the length of the wall; b. At all interconnections between concealed vertical and horizontal spaces such as occur at soffits, drop ceilings and cove ceilings; c. In concealed spaces between stair stringers at the top and bottom of the run and between studs along and inline with the run of stairs if the walls under the stairs are unfinished; and d. In openings around vents, pipes, ducts, chimneys, fireplaces and similar openings which afford a passage for fire at ceiling and floor levels, with noncombustible materials. l]Jo. In duplexes, draft stops shall be provided in / floor-ceiling assemblies and attics in line with walls separating units and separating units from common areas. Show stud size and spacing. Maximum allowable stud heights: Bearing wall: 2 x4 and 2x6 max. 10'; Non-bearing: 2x4 max. 14' max. 20'. Table 25-R-3. 2x6 Studs supporting two ceiling must be 3 x 4 Table 25-R-3. floors, a roof and or 2 x 6 at 16" o.c. t3. Note on A.I.T.C. Certificate of Compliance for glued laminated wood members shall be given to the building inspector prior to installation. Section 2505. 7/6/91 0. Note on the plans that "all weather-exposed surfaces shall have a weather-resistive barrier to protect the interior wall covering and that exterior openings shall be flashed in such a manner as to make then weatherproof". Section 1707. ] MECHANICAL (UNIFORM MECHANICAL CODE) All heating, ventilating, and cooling systems and appliances shall comply with the Uniform Mechanical Code. Show the size, location and type of all heating and cooling appliances or systems. Every dwelling unit, shall be provided with heating^ facilities capable, of maintaining a room temperature of 70 degree's F. at 3 feet above the floor in all habitable rooms. Show basis for compliance. UBC, Sec. 1212. Note on the plans that the FAU closet or alcove must be 12 inches wider than the furnace or furnaces being installed. UMC Section 704. Show minimum 30" deep... unobstructed working space in front of furnace. Section 505, UMC. Furnace shall not be installed in any bedroom, bathroom or in a closet or confined space with access only through such room unless specified as direct vent appliance, enclosed furnace or electric heating appliance. Section 704 UMC. 1. 1X2. Show source of combustion Chapter 6, UMC. air to furnace, per 14/. Show access to the attic containing equipment to be minimum 30 inches by 30 inches. The opening may be 22 inches by 30 inches if the equipment can be removed through such opening. Section 708 UMC. Note that passageway to the attic furnace shall be unobstructed and have continuous solid flooring not less than 24 inches wide, not more than 20 feet in length" through the attic. Section 708 UMC. . " 7. Show permanent electrical outlet and lighting fixture controlled by a switch for furnace located in attic or underfloor space. Section 708 & 709 UMC. Show details to comply furnace under the floor, roof or outside furnace. with Section 709 for or Section 710 for Show I.C.B.O. approval number for prefab fireplace. Show height of chimney above roof per I.C.B.O. approval or Table 37-B. Note on the plans that approved spark arresters shall be installed on all chimneys. Section 3704(h), Title 24. Note on plan: Gas vents and non-combustible piping, in walls, passing through three floors or less shall be effectively draft stopped at each floor or ceiling. UBC, Section 1706 (a) 6. 2. Provide dryer vent to 1903. outside. UMC, Section ELECTRICAL (KAPONAL ELECTRICAL CODE) All wiring shall Electrical Code. comply with the National Show on the plan electrical service, service panel and the the amperage of the the location of the location of any sub- panels. If service is over 200 amps, submit single line diagram, panel calculations. schedule and load 1/4. Note on the plans: "Electrical outlets shall / be installed in accordance with NEC Article ( 210-52". 156. Note on the plans: "Lighting outlets / controlled by a wall switch shall be provided in accordance with NEC Article 210-70". Note on the plans: "Light fixtures installed in clothes closets will comply with NEC Article 410-8". Note on the plans: "Convenience outlets in bathrooms, kitchen counter top(s) within 6 feet of the kitchen sink, outdoors, and in garages and basements (other than for laundry and similar equipment) shall be GFI protected." NEC, Art. 210-8. . Note electrical system ground to be provided per NEC, Art. 250-80(a), 81(c). PUMBIHG (UNIFORM PUMBIWG CODE) Show water heater size, type and location on plans. UPC, Section 1301. 10/2/91 y65. Show source for providing combustion air to fuel burning water heater. If wall openings in an enclosure are used, at least one-half of the required opening area shall extend into the upper twelve inches of the enclosure and one- half ;within the lower twelve inches. UPC, Section 1307. Fuel combustion water heater shall not be installed in bath or bedroom or in a closet opening into bath or bedroom. UPC, Section 1309. Provide adequate barrier to protect water heater from vehicle damage. An 18" platform for the water heater does not satisfy this requirement. UPC, Section 1310. Show I and P valve on water heater and show route of discharge line to exterior. UPC, Section 1007 (e). Show that water heater is adequately braced to resist seismic forces, when not connected by rigid! pipe. UMC Section 504(d). Show shower stall can accommodate a 30" circle and has a minimum floor area of 1,024 sq. in. UPC 909 (d). Provide clothes washer hook-up for each unit. Title 24, Part 3. New water closets and associated flushometer valves, if any, shall use no more than 1.6 gallons per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2, and urinals and associated flushometer valves, if any, .shall use no more than one gallon per flush and shall meet performance standards established by the American National Standards Institute Standard A112.19.2. H & S Code, Section 17921.3(b). NOISE IHSULATIOW (DOPLEXES)i Show details of duplex common (party) walls and floor/ceiling assemblies to achieve a Sound Transmission Class (STC) rating in walls of 50 decibels and an Impact Insulation Class (IIC) rating on floor/ceiling of 50 decibels. Title 24. Show how penetrations of assemblies for piping, electrical devices, recessed cabinets, bathtubs, soffits, or heating ventilating, or exhaust ducts shall be sealed, lined, or insulated to maintain required sound transmission rating. Title 24. Provide insulation in walls and ceiling to achieve STC of 50 between garage and living area if garage use is not controlled by resident. Title 24. ENERGY CONSERVATIQH Provide plans, calculations and worksheets to show compliance with current energy standards. The regulations require a properly completed and properly signed Form CF-1R to be either imprinted on the plans, taped to the plans or "sticky backed" on the plans, to allow the building inspector to readily compare the actual construction with the requirements of the approved energy design. All energy items shown on the plans must be in agreement with the information shown on the properly completed Form CF-1R. Specify on the building plans all of the mandatory energy conservation requirements as listed on the enclosure titled, "Mandatory Energy Conservation Requirements". Show the make, model and efficiency of the space heating (or cooling) system and provide heat loss calculations if the output exceeds 45,000 BTU/Hr. l>b. For room additions, show that the glazing area / of the addition does not exceed 16% of the newly-conditioned floor area, plus glazing removed or relocated due to the addition. 177. Provide fluorescent general lighting in / kitchen(s) per CAC, Title 24, 2-5352(J). CARLSBAD S.F.D. & DUPLEX SUPPLEMENT 1>8. Energy conservation design should be for Zone 7 7. 17/9. ' / . Floor drains must have auto-prime (city policy). For gas piping under slabs that serve kitchen island cooktops, see the attached Policy 91-46 for special sleeve and clean-out requirements. . Note exhaust fans cannot be ductless type (city policy). New residential units must be pre-plumbed for future solar water heating. Note "two roof jacks must be installed" where the water heater is in the one story garage and directly below the most south facing roof (City Ordinance No. 8093). To 8V Ror s- A" 1/17/92 (M \vv)u Note ''two 3/4" copper pipes must be installed to the most convenient future solar panel location when the water heater is not in a one story garage and is not directly below the most south facing roof. (City Ordinance No. 8093). 18/*." All piping for present or future solar water / heating must be insulated when in areas that are hot heated or cooled by mechanical means (city policy). 1/5. Incorporate the waterproofing details, on the attached Policy 80-8, where interior living space occurs below grade at the masonry wall(is). 186-. Show on the Title Sheet on the plans, the information required by the attached Developmental Services Sheet 112383. All , new residential buildings, including additions, require a soils report. Please submit two copies. Exception: If a room addition is limited to one story and 1000 sq. ft. in area, then a soils report is not required. Esgil Corporation will advise the City :to place their soils notice stamp on the plans. Heavy timber framing, minimum 6" x 10" beams and minimum 8" x 8" post, for the structural beam and column supporting the fire separation between the garage and living area above, is acceptable if shown on the plans. (city policy). All structures require a Class B roof covering, excep't room additions. If a room addition cover's all of the existing building (2nd story addition), then the above exception doesn't apply. City Ordinance 9792 requires two parking spaces/unit with clear area of 20'x20' i.e. no washing machines, etc. Show compliance. 1. All ^chimneys attached to any appliance or fireplace that burns solid fuel shall be equipped with an approved spark arrester. The net free area of the spark arrester shall be not less than four times the net free ara of the outlet of the chimney. The spark arrester screen shall have heat and corrosion resistance equivalent to 12 gauge wire, 19 gauge galvanized wire or 24 gauge stainless steel. Openings shall not permit the passage of spheres having a diameter larger than 1/2-inch and ;shall not block the passage of spheres having a diameter of less than 3/8-inch. Only tank-type water closets that use an average of 1.6 gallons of water per flush or less, and urinals and associated flushometer valves, that use an average of 1 gallon of water per flusn or less shall be installed in new construction. These provisions shall apply to existing buildings only when toilets are being replaced in existing bathrooms or installed in new bathrooms. MISCELLANEODS Please see additional corrections, or remarks, on the following page. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i.e., plan sheet, note or detail number, calculation page, etc. Please indicate here if any changes have been made to the plans that are not a result of corrections from this list. If there are other changes, please briefly describe them and where they are located in the plans. Have changes been made to the plans not resulting from this correction list? Please check. Yes No The City of Carlsbad has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number 619/560-1468, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact at Esgil Corporation. If you have any questions regarding City Building permit procedures, please contact Carter Darnell at the City of Carlsbad, 2075 Las Palmas Dr., telephone 619/438-1161. Thank you. Enclosures: 2. 3. 1/17/92 11 THE FOLLOWING NOTES SFECXFYIHG MANDATORY REQUIREMENTS SHOULD BE INCORPORATED ON PLAH SHEETS, OR CONIAIHED WITHIH JOB SFEdFICAXIOM DOOXEHIS. MAKDATOEY ENERGY CONSERVATION REOPIREHEHTS OF THE STATE OF CALTFORTOA (1) .All heating, ventilating, air conditioning, and water heating equipnent shall meet all of the requirements of the Appliance Efficiency Standards and shall be certified by the California Energy [Commission. (2) !A two stage thernostat, which controls the supplementary heat on its second stage, shall be provided for-heat punps. (3) Thermostats shall be equipped with an autonatic setback, which the building occupant can program to automatically set back the thermostat twice in 2k hours. (4) iEquipment which requires preventive maintenance to maintain efficient operation shall be furnished with complete necessary maintenance information. (5) All gas-fired fan type central furnaces, gas-fired fan type wall furnaces, and cooking appliances • shall be equipped with an intermittent ignition device. (6) 'All fan systems exhausting air to the outside shall be provided with backdraft dampers. (7) ! All transverse duct, plenum, and fitting joints shall be sealed with pressure sensitive tape or ! mastic to prevent air loss and shall~be insulated to conform to the provisions of Section 1005 of the UMC, 1982 Edition. (8) [ A vapor barrier is required in clinate zone 1, Ik, and 16. (9) All manufactured windows and sliding glass doors shall meet the 1972 ANSI air infiltration standards and shall be certified and labeled. (10) All swinging doors and windows leading to unconditioned areas shall be fully weather-stripped. (11) 'Storage type water heaters and storage and backup tanks for solar systems shall be externally wrapped with R-12 insulation or greater. (12) The five feet of pipe closest to the water heater, if- outside conditioned space, shall be insulated with a minimum of R-3. Steam and steam condensation, return piping and recirculating hot water piping outside the building envelope shall be insulated in accordance with T20-1406(d). (13) Lamps used in luminaries for general lighting in kitchens and bathrooms shall have an efficiency of not less than 25 lumens per watt. (14) Showerheads and faucets shall be equipped with flow restrictors as outlined in the appliance efficiency standards and shall be certified to the Energy Commission. (15) Masonry and factory-built fireplaces on exterior walls, shall be equipped with tight-fitting closeable metal or glass doors covering' the entire opening of the firebox; a combustion air intake equipped with a readily accessible, operable, and tight fitting damper to draw air from the outside of the building; and a. tight fitting flue damper with a readily accessible control. (16) ! Insulation used shall comply with California Quality Standards. (17) The insulatioa installer shall post, a signed certificate. .'.Section. 276.. Insulation Certificate (All Occupancies). After installing insulation, the installer shall post in a conspicuous location in the building a certificate signed by the installer and the builder stating that the installation conforms the requirements of Title- 2k, Part 2, Chapter 2-53, and that the materials installed conform with the requirements of Title 20, Chapter 2, Subchapter k, Article 3. The certificate 1 shall state the manufacturer's name and material identification, the installed "R" value, and (in applications of loose fill insulation) the minimum installed weight per square foot consistent with ' the manufacturer's labeled density for the desired "R" value. (18)' For infiltration control all openings and penetrations must be caulked and sealed, such as around windows, at sole plates, and openings for utility pipes and wires. Fora ECH 3/5/86 Date:Jurisdiction CART.SRAD Prepared byivTi'Wi PLAN CHECK N0._ VALUATION AND PLAN CHECK FEE Q Bldg. Dept. D Esgil BUILDING ADDRESS J 14-9 APPLICANT/CONTACT<7^Q(5)0 BUILDING OCCUPANCY l^-^ PHONE NO . 'I 58 -33 7 2^ DESIGNER PHONE (l TYPE OF CONSTRUCTION CONTRACTOR PHONE BUILDING PORTION fVotf ,ii;in^/V Air Conditioning: Commercial Residential Res. or Conun. Fire Snrinklers Total Value BUILDING AREA °^G 0>, VALUATION MULTIPLIER H6.00 '@ @ @ • • VALUE -' ^008i n,oo& Building Permit Fee. $ Plan Check Fee $ COMMENTS: SHEET OF 12/87 City of Carlsbad DATE: Engineering Department BUILDING PLANCHECK CHECKLIST PLANCHECK NO. CJg> BUILDING ADDRESS: PROJECT DESCRIPTION: ASSESSOR'S PARCEL NUMBER:EST. VALUE ENGINEERING DEPARTMENT APPROVAL The item you have submitted for review has been approved. The approval is based on plans, information and/or specifications provided in your submittal; therefore any changes to these items after this date, including field modifications, must be reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. 1st CHECK By:_Date: 2nd CHECK By:.Date: 3rd CHECK By:_Date: DENIAL Please see the attached report of deficiencies marked with S. Make necessary corrections to plans or specifications for compliance with applicable codes and standards. Submit corrected plans and/or specifications to this office for review. By:.Date: By:.Date: By:.Date: FOtt OFFICAL USE ONLY ENGINEERING! AUTHORIZATION TO ISSUE BUILDING PERMIT; BY: ATTACHMENTS EH Dedication Application D Dedication Checklist D Improvement Application D Improvement Checklist D Future Improvement Agreement LJ Grading Permit Application D Right of Way Permit Application D Sewer Fee Information Sheet CONTACT PERSON NAME:. ADDRESS:. PHONE: P:\docs\chklst\bp0001 .frm REV 5/18/92 2075 Las Palmas Dr. • Carlsbad, CA 92OO9-1576 • (619) 438-1161 • FAX (619) 438-O894 BUILDING PLANCHECK CHECKLIST SITE PLAN 2ncV 3rd/ D D D 1. Provide a fully dimensioned site plan drawn to scale. Show: A. North Arrow D. Property Lines Easements 8. Existing & Proposed Structures E. Easements C. Existing Street Improvements F. Right-of-Way Width & Adjacent Streets D D D 2. Show on site plan: A. Drainage Patterns C. Existing Topography B. Existing & Proposed Slopes D D D 3. Show on a section drawing or include a note stating that there is a minimum of 6" difference between the finished floor and the finished grade elevation adjacent to the structure. D D D 4. Include note: "Surface water to be directed away from the building foundation at a 2% gradient for no less than 5' or 2/3 the distance to the property line (whichever is less)." [Per 1985 UBC 2907(d)5]. On graded sites, the top of any exterior foundation shall extend above the elevation of the street gutter at point of discharge or the inlet of an approved drainage device a minimum of 12 inches plus two percent" (per 1990 UBC 2907(d)5.). D D CD 5. Include on title sheet A. Site address B. Assessor's Parcel Number C. Legal Description For commercial/industrial buildings and tenant improvement projects, include: Total building square footage with the square footage for each different use, existing sewer permits showing square footage of different uses (manufacturing, warehouse, office, etc.) previously approved. EXISTING PERMIT NUMBER DESCRIPTION P:\docs\chklst\bp0001.frm Page 1 of 4 REV 5/18/92 BUILDING PLANCHECK CHECKLIST DISCRETIONARY APPROVAL COMPLIANCE 6. Project does not comply with the following Engineering Conditions of approval for Project No. _ Conditions were complied with by: _ Date: _ DEDICATION REQUIREMENTS D D D 7. Dedication for all street Rights-of-Way adjacent to the building site and any storm drain or utility easements on the building site is required for all new buildings and for remodels with a value at or exceeding $ -pursuant to Code Section 18.40.030. o Dedication required as follows: Attached please find an application form and submittal checklist for the dedication process. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Dedication completed by Date: IMPROVEMENT REQUIREMENTS D 8a. All needed public improvements upon and adjacent to the building site must be constructed at time of building construction whenever the value of the construction exceeds $ -pursuant to Code Section 18.40.040. Public improvements required as follows: Please have a registered Civil Engineer prepare appropriate improvement plans and submit them together with the requirements on the attached checklist for a separate plancheck process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. Attached please find an application form and submittal checklist for the public improvements requirements. Provide the completed application form and the requirements on the checklist at the time of resubmittal. Improvement Plans signed by: Date: P:\doc«\chkl»t\bp0001.frm Page 2 Of 4 REV 5/18/92 BUILDING PLANCHECK CHECKLIST 1stv/ 2ndV 3rcV D E3 CH 8b. Construction of the public improvements may be deferred pursuant to code Section 18.40. Please submit a letter addressed to the City Engineer, requesting deferral of required improvements together with a recent property title report on the property and processing fee of $ so we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a Building Permit. Future public improvements required as follows: Improvement Plans signed by: Date:. D D D 8c. Enclosed please find your Future Improvement Agreement. Please return signed and notarized Agreement to the Engineering Department. Future Improvement Agreement completed by: Date: D D D 8d. No Public Improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City Inspector prior to occupancy. GRADING PERMIT REQUIREMENTS The conditions that invoke the need for a grading permit are found in Section 11.06.030 of the Municipal Code. D D D 9a. Inadequate information available on Site Plan to make a determination on grading requirements. Include accurate grading quantities (cut, fill import, export). D D D 9b. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be Submitted together with the completed application form attached. NOTE: The Grading Permit must be issued and rough grading approval obtained prior to issuance of a Building Permit. Grading Inspector sign off by: Date: P:\doc»\chkl«t\bp0001.frm Page 3 of 4 REV 5/18/92 BUILDING PLANCHECK CHECKLIST MISCELLANEOUS PERMITS 1stv/ 2ndv/ 3rdv/ D D D 10. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-Way and/or private work adjacent to the public Right-of-Way. Types of work include, but are not limited to: street improvements, trees, driveways. A separate Right-of-Way permit issued by the Engineering Department is required for the following: - Please complete attached Rightof-Way application form and return to the Engineering Department together with the requirements on the attached Right-of-Way checklist, at the time of resubmittal. D D D 11. A SEWER PERMIT is required concurrent with the building permit issuance. The fee is noted in the fees section on the following page. D D D 12. INDUSTRIAL WASTE PERMIT is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of a Permit. Industrial waste permit accepted by: Date: P:\docs\chktst\bp0001.frm Page 4 Of 4 REV 5/18/92 CALCULATIONS WORKSHEET EDU CALCULATIONS: EDU's: FEES REQUIRED: D 1. PARK-IN-LIEU FEE EDU's: FEE/EDU: D 2.TRAFFIC IMPACT FEE ADT's: FEE/ADT: D 3. BRIDGE AND THOROUGHFARE FEE ADT's: FEE/ADT: D 4. FACILITIES MANAGEMENT FEE ZONE: FEE/EDU: D 5. SEWER FEES PERMIT No. . EDU's: FEE/EDU:. BENEFIT AREA: FEE: D 6. SEWER LATERAL REQUIRED (2,500 DEPOSIT) REMARKS: APT CALCULATIONS: ADT's: P:\doc8\chkl8t\bp0001.frm REVS/18/92 PLANNING CHECKLIST Plan Check No. _22l^bTAddress I 7V? Planner VAN LYNCH Phone 438-1161 ext. 4325 (Name) APN: - /^"j^b/TXf^ 0) 10Q Q IDO Type of Project and Use Zone j^f _ Facilities Management Zone / _ Legend * SI I I al a. em § a. Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck numfier where deficiency was identified O Environmental Review Required: YES DATE OF COMPLETION: TYPE oraa Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval ; Discretionary Action Required: YES NQ^X TYPE DATE:APPROVAL/RESO. NO. PROJECT NO. OTHER RELATED CASES: Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval : G^DI:D California Coastal Commission Permit Required: YES NO &( DATE OF APPROVAL: ' San Diego Coast District, 3111 Camino Del Rio North, Suite 200, San Diego, CA. 92108-1725 (619) 521-8036 Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval teraD D Landscape Plan Required: YES NO See attached submittal requirements for landscape plans Site Plan: an Zoning: 1. Provide a fully dimensioned site plan drawn to scale. Show: North arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. 2. Show on Site Plan: Finish floor elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes and driveway. 3. Provide legal description of property. 4. Provide assessor's parcel number. 1. Setbacks: LTna (zma HT] D nan Front: Int. Side: Street Side: Rear: 2. Lot coverage: 3. Height: 4. Parking: Additional Comments Required Required Required Required Required Required Spaces Required Guest Spaces Required *€> Shown "27* 6 A^" Shown SO " • — Shown • — y^' Shown >*fe>'" <^<rwf Shown £$&% O*> Shown <OV9^ 2 — Shown -3 Shown OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER DATE PLNCK.FRM