Loading...
HomeMy WebLinkAbout1756 Blackbird Cir; ; CBR2018-3504; Permit(City of Carlsbad Residential Permit Print Date: 02/06/2019 Permit No: CBR2018-3504 Job Address: Permit Type: Parcel No: Valuation: Occupancy Group: # Dwelling Units: Bedrooms: 1756 Blackbird Cir BLDG-Residential 2156020100 $8,400.00 Work Class: Lot#: Reference#: Construction Type: Bathrooms: Orig. Plan Check#: Cogen Status: Applied: Issued: Permit Finaled: Inspector: Closed . Finaled 12/24/2018 12/24/2018 MColl Plan Check#: Final Inspection: 2/6/2019 2:49:SlPM Project Title: Description: MORSE: 21 ROOF MOUNT PV, 7.56KW W/ BATTERY BUILDING PERMIT FEE ($2000+) BUILDING PLAN CHECK FEE (BLOG) SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL Total Fees: $182.44 Owner: COOWNER MORSE SILAS & COTNER DANIELLE 17S6 Blackbird Cir CARLSBAD, CA 92011 Total Payments To Date: $182.44 Contractor: N B BAKER ELECTRIC INC 1298 Pacific Oaks Pl Escondido, CA 92029-2900 760-745-2001 Balance Due: Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. $0.00 1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov $106.09 $74.26 $1.00 $1.09 {ci~of Carlsbad RESIDENTIAL BUILDING PERMIT APPLICATION B-1 Plan Check~~QD04 Est.Value~ PC Deposit --------- Date \2.-2..\...\-~ Job Address 1756 Blackbird Circle Suite: APN: 215 602 01 00 ----- CT/Project#:. __________ Lot#:. ____ Fire Sprinklers: yes/ no Air Conditioning: yes/ no BRIEF DESCRIPTION OF WORK: PV System -Energy Storage 1 LG Battery 5kW 0 Addition/New: _____ .Living SF, ____ Deck SF, ____ Patio SF, ____ Garage SF Is this to create an Accessory Dwelling Unit? Yes/ No New Fireplace? Yes/ No, if yes how many? __ D Remodel: ____ SF of affected area Is the area a conversion or change of use ? Yes/ No □ Pool/Spa: ____ SF Additional Gas or Electrical Features? ____________ _ {21 Solar: 7.56 KW, 21 Modules, Mounte~ Ground, Tilt: Ye~RMA: Yes~atte~ No Panel Upgrade: YeslciJ D Reroof: ___________________________________ _ D Plumbing/Mechanical/Electrical Only: ________________________ _ D Other: ____________________________________ _ APPLICANT (PRIMARY) Name: Ramon Lopez Address: 2140 Enterprise St City: Escondido Phone: 760-546-6023 State:_Cc..a_--'Zip: 92029 Email: etanner@bakerhomeenergy.com DESIGN PROFESSIONAL Name: _________________ _ Address: _______________ _ PROPERTY OWNER Name: Silas Morse Address: 1756 Blackbird Circle City: Carlsbad State: CA Zip: 92011 Phone: 760-8407959 Email: silasmorse@hotmail.com CONTRACTOR BUSINESS Name: Baker Electric Home Energy Address: 2140 Enterprise St City: ________ State: ___ ,Zip: ____ _ City: Escondido Phone: 760-546-6000 State:_C_a __ .Zip: 92029 Phone: _________________ _ Email: _________________ _ Architect State License: ___________ _ Email: etanner@bakerhomeenergy.com State License: 858088 Bus. License: 8l II.( I l. '2-I I (J 'L {Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he/she is licensed pursuant to the provisions of the Contractor's License Law {Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he/she is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.S by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}). 1635 Faraday Ave Carlsbad, CA 92008 Ph: 760-602-2719 Fax: 760-602-8558 Email: Building@carlsbadca.gov B-1 Page 1 of 2 Rev. 06/18 ( OPTION A): WORKERS'COMPENSATION DECLARATION: I hearby affirm under penalty of perjury one of the following declarations: □ I have and will maintain a certificate of consent to self-insure for workers' compensation provided by Section 3700 of the Labor Code, for the performance of the work which this permit is issued. 13 I have and will maintain worker's compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy number are: Insurance Company Name: 00:::'c:.'.:_"c:•c.P":::b:::lic:.c.cln--'s-'C'-'o--------------- Policy No. MWC3155500 Expiration Date: -='--1'---1:.:9 _______ _ □ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to be come subject to the workers' compensation laws of California. WARNING: Failure to secure workers compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to $100~000.00, in a ition the to the cost of compensation, damages as provided for in Section 3706 of the labor Code, interest and attorney's fees. CONTRACTOR SIGNATURE: (2. C k i,LIAGENT DATE: /2-. LY· ( ~ ( OPTION B ): OWNER-BUILDER DECLARATION: I hereby affirm that I am exempt from Contractor's License Law for the following reason: □ I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's License law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale). □ 1, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's license law does not apply to an owner of property who builds or improves thereon, and contracts for such projects with contractor{s) licensed pursuant to the Contractor's License law). □ I am exempt under Section _______ Business and Professions Code for this reason: 1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. □ Yes □ No 2. I (have/ have not) signed an application for a building permit for the proposed work. 3. I have contracted with the following person (firm) to provide the proposed construction (include name address/ phone/ contractors' license number): 4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name/ address/ phone/ contractors' license number): 5. I will provide some of the work, but I have contracted {hired) the following persons to provide the work indicated (include name/ address/ phone/ type of work): OWNER SIGNATURE: __________________ □AGENT DATE: _____ _ CONSTRUCTION LENDING AGENCY, IF ANY: I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (l) Civil Code). Lender's Name: ____________________ _ Lender's Address: ____________________ _ ONLY COMPLETE THE FOLLOWING SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY: ls the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the Presley-Tanner Hazardous Substance Account Act? □ Yes □ No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? □ Yes □ No Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? □ Yes □ No IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT. APPLICANT CERTIFICATION: I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction. I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height. EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time afterthe wo,k is commenced to, a pedod of 180-:?°6.4.4 Unifmm B,ilding Codel. APPLICANT SIGNATURE: __f::::::_::_ =2:-::= DATE: /2.-Z-'1-{ r 1635 Faraday Ave Carlsbad, CA 92008 8-1 Ph: 760-602-2719 Fax: 760-602-8558 Page 2 of 2 Email: Building@carlsbadca.gov Rev. 06/18 )' / •' ,' ': ' I " ' z . . PERMIT INSPECTION HISTORY REPORT (CBR2018-3504) Porinit Type: BLDG-Residential Application Date: 12/24/2018 Wo1k Class: Cogen Issue Date: 12/24/2018 Status: Closed -Finaled Expiration Date: 08/05/2019 Scheduled Date Actual Start Date Inspection Type IVR Number: 16179 Inspection No. Inspection Status ·-·-··-·--------··---·------------------- 01/24/2019 01/24/2019 01130/2019 01/30/2019 02/06/2019 02/06/2019 BLDG-35 Solar Panel 082123-2019 BLDG-Final Inspection Checklist Item BLDG-Building Deficiency 082124-2019 Checklist Item BLDG-Building Deficiency BLDG-Electrical Final BLDG-35 Solar Panel 082628-2019 BLOG-Final Inspection Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency Checklist Item BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Electrical Final BLDG-Electrical Final BLOG-35 Solar Panel 083196-2019 BLDG-Final Inspection Checklist !torn BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency 083197-2019 Checklist Item Failed COMMENTS Not ready Failed COMMENTS Not ready Partial Pass COMMENTS Partial Not ready Partial Pass COMMENTS Not ready Partial, see card Passed COMMENTS Partial Not ready Passed COMMENTS Owner: Subdivision: Addross: Primary Inspector Michael Colllns Michael Colllns Michael Collins Michael Collins Michael Collins Mlchael Collins BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Building Deficiency BLDG-Electrical Final BLDG-Electrical Final BLDG-Electrical Final Release emailed to SDGE Not ready Partial, see card February 06, 2019 COOWNER MORSE SILAS & COTNER DANIELLE CARLSBAD TCT#85-35 PHASE I UNIT#C 1756 Blackbird Cir Carlsbad, CA 92011-5008 Reinspection Complete Re inspection Complete Passed No Reinspection Complete Passed No No Reinspection Incomplete Passed Yes No Reinspection Incomplete Passed No Yes No Yes Complete Passed Yes Yes No Complete Passed Yes No Yes Yes No Yes Page 1 of 1 (2x)AWG #10 (PV WIRE) PER STRING & (1x)#8 BARE COPPER GROUND - SEE NOTE#5 LG MODULES LG 360-Q1C-A5 MODULE(s) (11x) MODULES IN SERIES 3/4" EMT (4x) #10 AWG (THWN-2) & 1 #8 GROUND - (SEE NOTE #4) (FOR GROUNDING SEE NOTE #6) POWER OPTIMIZER P370 SOLAR EDGE i (11x) POVVER OPTIMIZERS LG MODULES LG 360-Q1C-A5 MODULE(s) (1 Ox) MODULES IN SERIES PROVIDE ARRAY JUNCTION BOX (FOR GROUNDING SEE NOTE #6) ON ROOF (AS REQUIRED) POWER OPTIMIZER P370 SOLAR EDGE l(10x} POWER OPTIMIZERS 3/4" EMT (2x) AWG #10 THWN-2 WIRE (1x) AWG #8 GROUND (1x) CATS 600V CONTROL (2x) AWG #16 600V THERMAL V ill FACTORY INTERNAL CONNECTIONS CLARIFIED FOR THESTOREDGEINVERTER INVERTER 3/4"EMT (3x) AWG #8 THWN-2 WIRE (1 x) AWG #8 GROUND ELECTRICAL NOTES· 1. THE PHOTOVOLTAIC CONNECTION IN THE PANEL BOARD SHALL BE POSITIONED AT THE OPPOSITE (LOAD) END FROM THE INPUT FEEDER LOCATION OR MAIN CIRCUIT LOCATION PER CEC ART. 690.64 WHEN USING THE 120% OF RATING ALLOWANCE FOR DETERMINING THE TOTAL RATING OF OVER CURRENT DEVICE AS PER 705.12(0)(2)(3)(b). A CONNECTION AT flIHFR FNP B\JT NOT BOTH ~NPS OF A CENTER-Ff P PANEL BOA RP IN PWELUNG SHALL RE PERMITTED ½/HERE THE SLIM OE 125 PERCENT OF THE POWER SOURCE(§) OUTPUT CIRCUIT CURRENT AND RATING QF THE OYERC\JRRENT DEVICE PROJECTING THE BlJ§BAR DOES NOT EXCEED 120 PERCENT OF THE CURRENT RATING Of THE BUSBAR· SEE ATTACHED TENTATIVE INTERIM AMENDMENT [NEC 2014 70512(0}(2)(3\(e)) 2. SOLAR CIRCUIT BREAKERS SHALL BE SUITABLE FOR BACKFEED. {CIRCUIT BREAKERS THAT ARE MARKED "LINE" AND "LOAD" ARE NOT SUITABLE FOR BACKFEED.) 3. LABELS ARE REQUIRED ON ALL INTERIOR AND EXTERIOR PHOTOVOLTAIC DC CONDUIT, RACEWAYS, ENCLOSURES AND CABLE ASSEMBLIES. LABEL SHALL READ "WARNING: PHOTOVOLTAIC POWER SOURCE" Vv'ITH A RED BACKGROUND, WHITE LETTERING, MINIMUM 3/8" LETTER HEIGHT, ALL CAPITAL LETTERS, ARIAL OR SIMILAR FONT, NON-BOLD, AND ON A RED BACKGROUND. THE MATERIALS USED SHALL BE REFLECTIVE, \NEATHER RESISTANT AND SUITABLE FOR THE ENVIRONMENT. LABEL SHALL BE LOCATED AT EVERY 10 FEET OF CONDUIT, Vv'ITHIN 1' OF TURNS OR BENDS, WITHIN 1' ABOVE AND BELOW PENETRATIONS OF ROOF/CEILING ASSEMBLIES, WALLS, OR BARRIERS AND AT ALL PV COMBINER AND JUNCTION BOXES. U>- ~U I-Ck:'. uw wz ..... wW ~w w2 ~ ... <(~ ~ ~ ;:! 0 0 S!o QO z'l' O<O o;i; ffLs ._~~ .,-w W .,z -o I<:,: il! .. I!! z w 4. IDENTIFICATION FOR UNGROUNDED CONDUCTORS OF BRANCH CIRCUITS SUPPLIED FROM DIRECT-CURRENT SYSTEMS SHALL COMPLY ca I ~ N \JVITH 210.5(C)(2)(a) AND (b). IDENTIFICATION AND GROUPING OF PHOTOVOLTAIC DC CIRCUITS SHALL COMPLY WITH NEC 690.31 (B) AND LICENSED PROFESSIONAL SHALL BE SEPARATED FROM OTHER NON PV SYSTEM CONDUCTORS. PHOTOVOLTAIC SYSTEM GROUNDING COMPLIES 'v'\/ITH 690.41 & ~A-/4_--- SB0.35. TED BAKER 5. AUXILIARY GROUNDING IS PROVIDED FOR THE MOUNTING RAILS AT EACH ROW UTILIZING THE BURNDY WEES-LUG 8.0 (UL 2703) AS PER CEC 690.47(0). PHOTOVOLTAIC SYSTEM GROUNDING COMPLIES 'v'\/ITH 690.41 & 690.35. EXPOSED NON-CURRENT CARRYING METAL PARTS OF PHOTOVOLTAIC RACKING, EQUIPMENT, AND CONDUCTOR ENCLOSURES SHALL BE GROUNDED IN ACCORDANCE TO NEC 690.47 (C)(3), 250.64(C), 250.66, & 250.134 OR 250.136(A), AND SIZED PER 250.166 REGARDLESS OF VOLTAGE. THE GEC / EGC SHALL BE CONTINUOUS, OR WHEN SPLICED, THE SPLICE SHALL BE MADE BY IRREVERSIBLE CRIMP PER NEC 250.64 (C) 6. EACH MODULE SHALL BE GROUNDED PER THE MANUFACTURER'S INSTRUCTIONS USING THE INTEGRATED BONDING MIDCLAMP / COMPONANTS (SEE SOLAR MOUNT SPEC SHEET), AND AT EACH ROW UTILIZING BURNDY WEES-LUG 8.0 (UL 2703). SEE GROUNDING LUG SPEC SHEET. 7. IF THE EXISTING GROUNDING ELECTRODE SYSTEM CAN NOT BE VERIFIED, OR IS ONLY METALLIC WATER PIPING, OR IT HASA RESISTANCE GREATER THAN 25 OHMS, IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSTALL A SUPPLEMENTAL GROUNDING ELECTRODE AT LEAST 6' FROM THE EXISTING GROUNDING ELECTRODE. 8. ELECTRICAL EQUIPMENT INSTALLED SHALL BE LISTED, LABELED, OR CERTIFIED FOR ITS USE BY A NATIONALLY RECOGNIZED TESTING lABORATORY (NRTL). C10 & C46 LIC#858088 EXP. 4130/19 Li.j t:,! CJ) ::;; w (.) tii C G 3: s! .II:: ~ co 5"? >t--0 6 I a. Li.j N cii w ~ 3: O,.ll:: tii It) >-~ w z w 9. INVERTER IS NEC 690.12 RAPID SHUTDOWN COMPLIANT; SEE SPECS. UPON TURNING OFF THE INTEGRATED DC DISCONNECT, AND/OR 1-----------.1 THE INVERTER OCPD AT THE MSP, THE PV CONDUCTORS SHUTDOVVN Vv1THIN 30 SECONDS AS PER NEC 690.12(2) 10. ,. LG CHEM BATTERY INCLUDES AN ON BOARD SWITCH FOR DISCONNECTING MEANS TO COMLY 'v'\/ITH 690.71 (H)(1). THE ENERGY STORAGE DISCONNECTING MEANS IS THE EXTERNAL SAFETY S\MTCH AT THE INVERTER AS PER 690.7(H)(4). THIS RAPID SHUTDOvVN SWITCH DISCONNECTS THE CONDUCTORS OF THE PV AND BATTERY. h RECORD COPY RECEIVED 60 A LOCKABLE ""C co ..c "' Q) .:::: CJ co C C: () C Q) ai ..-.... C 'C (.)..-N ·-,.._ 0 "' ·-N C Q) () a, co ~~~ '-. / lsm';,_R EDGE ;TOREDGEl Bl-DIRECTIONAL INVERTER AC DISCONNECT --l-----.l-------1---1----1 ADJACENT TO 1--+--+----------, FEB O 4 2019 CITY OF l@rU/Ln,~,~ARLsaAo 7!X13'1'1~~/)#; a::: E<C It) :.c () .... N 40A 2P INVERTER DISCONN>C~T+----1---, (INTEGRATED AC AND DISCON CTS W/ TYPe.4+-AA<C ~ PROTECTION '-----+------" INTEGRATED INTO WIONBOARD $WITCH FOR DISCONNECTING MEAf,/S_ LG CHEM BATTERY RESU10H INVERTER {NEC 690.11 COMPLIANT) OUTSIDE WALL (9 RAPID SHUTDOVVN SWITCH (SEE N('.)TE # 9) V 5-,,:,/1/. 9.8-,,:,/1/h NEMA3R ''-----..___3/4"EMT ,--S-O_lA_R_E_D,1,G_E_AU_T_O __ --. (3x) AWG #8 THWN-2 WIRrl!J 3/4" EMT (3x) AWG #10 THWN-2 WIRE (1x) AWG #8 GROUND NEW 125A PROTECTED LOADS SUB PANEL (OUTSIDE WALL) I ,__ n ''--.. I "I--25A 2/P BREAKER PANEL & ME'tEIPN / (NOT CENTER FED) EXISTING 200A /j MAIN BREAKER Q) ~ "' (.) ... co z 0 iii c.. ::!: (0 <( LO r---..- REVISIONS: AL 01/25/2019 DRAWN BY: 01 • 40APVBREAKER DATE 12/11/2018 LOCATED ADJACENT TO STOREDGEINVERTER TRANSFORMER (1 x) AWG #8 GROUND (2x) AWG #24 TEMP SENSOR SEAUTO TX-5000 RELOCATED EXISTING I ~~ JOBNO, S13989 ~----tt-' (SEE NOTE #1 FOR LOCATION) SINGLE LINE DIAGRAM /J/, ..,,.....+-(7x) 20A / 120V \\'"' I (2x)15A/120V CIRCUITS FER IDENTIFIED____,/© ~~ ~ PEi~1~61~~C~ION 250.52(A)(3) C6Q. 20\'c}-3-..JVT (SEE ELECTRICAL NOTE #7) SHEET: