HomeMy WebLinkAbout1760 CAPE MAY PL; ; CB042473; Permit06-21-2004
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Miscellaneous Permit Permit No: CB042473
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Valuation:
Reference #:
Project Title:
1760 CAPE MAY PL CBAD
MISC
2073120900
$4,777.00
Subtype: REROOF
Lot #: 0
COX RES-1700 SF STD WEIGHT
Status: ISSUED
Applied: 06/21/2004
Entered By: RMA
Plan Approved: 06/21/2004
Issued: 06/21/2004
Inspect Area:
Applicant:
COX TIMOTHY L&ROSEMARY H
36 CARIBE ISLE
NOVATOCA 94949
Owner:
COX TIMOTHY L&ROSEMARY H
36 CARIBE ISLE
NOVATO CA 94949
Miscelaneous Fee #1 PERMIT FEE
Miscelaneous Fee #2
Additional Fees
$102.00
$0.00
$0.00
TOTAL PERMIT FEES $102.00
Total Fees: $102.00 Total Payments To Date:$0.00 Balance Due:$102.00
4814 06/21/04 0002 01 02
FINAL APPROVAL
DATE 7" ? -
SIGNATURE
-2004 WED 07:54 AM CITY OF CARSLBAD
.ftMIT APPLICATION
CITY OF CARLSBAD BUILDING DEPARTMENT
1635 Faraday Ave., Carlsbad, CA 92008
FAX NO. 760 602 8558 \P-v02
FOR OFFICE USE ONLY
PLAN CHECK
EST. VAL
«K!3« •
7 7 7
Plan Ck. Deposit
Validated B}
Data
f
.
AA"f
Address (include Bids/Suite *)Business Name (« this eddrBsal
Legal Description uot No.Subdivision Mima/Number Unit No;Phase No.Total * of units
Proposed USB
V
Name State/Zip Telephone *Fax*
3<=> t&nh'z Zsfe A/CVATC
Name Address City State/Zip Telephone #
(Sec. 7031.6 Business end Professions Code: Any Cily or County wWch requires • permft to eOTUVuCI, alter, improve, demo4i«h or repair any structure, prior IB its
issuance, af» requires tha applicant for such permit to tile a signed statement that ha Is licensed pursuant to in* provisions of the Contractor's License Uw
[Chapter 9, commending wKJi Section 7000 of Division 3 of the puajnaM and Profesaons Code] or that ha is exempt ttwrefronvend th« buiB for the alleged
exemption. Any violation of Section 7031 .fi by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($600)}.
Name
State UcartM t
Designer Name
State License *
Address
Ucensa Class
Addresa
City State/Zip
City Business License »
City State/Zip
Telephone *
Telephone
fiMWll^^
Workers' ComDansatlcui Declaration: 1 heieby aftvfrn under penalty of perjury one of the following declarations;
Q I have and will maintain a certificate of consent to self-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance
of the work for which this permit ia issued.
Q I hive and wBI maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permh is
issued. My worker's compensation Insurance carrier end policy number are:
Insurance Company __ Policy Ho. Expiration Date
(THIS SECTION NEED NOT M COMPLETED & THE PERMIT IS FOR ONE HUNDRED DOLLARS [a 1001 Oft LESS)
Q CERTIFICATE OF EXEMPTION: \ certify that in the performance of the wort tor which this permit is issued, 1 shell not employ any person in any manner so as
to become subject to the Workers' Compensation Laws of California,
WARNING; FeOura to Meure workers' eamoenutfen cover*0a ta unlawful and she! subject an empJcyaf to crMnef penaltle* and civil flnea up to one hundred
thousand doUara (4100,000), fei addition to the coat of compensation, damaga* M provided for In Section 3706 of ttw Labor code. Interest and attorney's fees.
SIGNATURE . DATE
hereby affirm that I am exempt from the Contractor's Ucenae Law for the following reason:
Q I, as owner of the property or my employee! with wages aa their sola compensation, will do the work and the structure I* not intended or offered for s«j$
(Sec. 7044, Business and Professions Coda: The Contractor's license Law does not appfy to an owner ot property who builds or improves thereon, and who doe*
auch work hlmaetr or through his own employees, provided that such improvements are not Intended or offered for salt. If, however, the building or improvement is
aokl within one yur of completion, the owner-builder will have the burden of proving that he did not build or Improve for the purpose of sale).
.Q I/ aa owner of the proparty, am exclusively contracting with licensed contractors to conciruct the project (Sec. 7044, Business and Professions Code: The
Contractor's' License Lew doea not epply to an owner of property who builds or Improves thereon, and contracts for auch projects with corrtractorls) licensed
pursuant to the Contractor's License Law).
JE3^ ' «m exempt under Section ___ _ Business end Profaaslona Coda lor tNa reason:
1 . I personalty plan to provide tha major labor and matwiais for construction of ihe proposed properly Improvement.^ YES QNQ
2. I (have / have not] alg/ied an application for e building permit for the proposed work,
3. I have contracted with the following person (firml to provide the propoasd construction (induda rwme / address / phone number / contractors license number):
4. I plan to provide portions of the work, but I have hired the following parson to coordinate, supervise and provide the major wofk (Include name I address / phons
number / comrectora license numberd^ _ ______ _
5. I will provide some of the work. Out I have contracted (hired) the fallowing persons to provide the work indicated (include name / address / phone number / type
Of work): _ ^~^ ~ _ „ __ ,
PATE'PROPERTY OWNER SIGNATURED
« V \7 V V V V
,»jS!»^r£b5«l&D«tiR^^
'« tr,5 apoMCWrt Of future building occupant required to submit A business plan, acutely htlirdoua matwiBls tagistratioft form or riak managmnam and pravantion
pfoflnrrtbrider Swtiona 26605, 25633 or 26634 of tha PrealeyTannar Hazardous Substance Account Act? • Q VES Q NO
is the applicant. cMtewa^MJiWing oeeup«nt required to obtain a permit from the air pollution control district or air quality msnagamant district? Q YES Q NO
Is the facility to be corwtructed within 1,000 feat of the outer boundary of« school rite? Q YES O NO
IF ANY OF THE ANSWERS ARE Y£S, A FINAi CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET Oft IS MEETING THE
REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POIUJTION CONTROL DISTRICT.
1 he*»by Bfllim that there is a construction Innding agancy for the performance of The work for which this parmlt is issued (Sac. 303711) Civil Coda}.
LENDER'S NAME,LENDER'S ADDRESS
certify that I rxvfl raad the application and nata that th« ibova Information la cornet and that thv information on tha plane is •ccuf««, (igtaa to comptv with All
City ordlnancas and Stata Iaw» relating to building construction. ' har«by authorize rapracantativM of th» CitV of Ciriab«d to antar upon tha above mentioned
property for Inspection purpoxn. 1 ALSO AQREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CAflLSBAO AGAINST AU LIABILITIES.
JUDQMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT,
OSHA: An OSHA permit to required for excavations over 5'0" d««p and demolition at construction of atructurfla ov«r 3 stories in height.
EXPIRATION: Every permit issued by the txjildng Official under the provisions of this Coda shall expire by limitation and become null and void if the building or work
authorized by such permit is not commenced within 180 days from the date of euch permit gr if tha building or work authorized by such permit Is suspended or abandoned
at any time ^ertfw work )s comrnerw^ for a period on M days (S^on 106.4.4 Uniform puildlng Code).
APPLICANT'S SIGNATURE ~\~ Js&l&t, <4?~ /X^T ' DATE
WHITE: Rle YELLOW: Applicant PINK: Finance
06/21/2004 13:43 FAI 5105873033 VT Griffin Services |g]002
86/21/2804 00:26 7S37291346 GOLDEN KEY PRDPERTIQ RAGE 02
City Of Carlsbad
SUPPLEMENTAL BUILDING PERMIT APPLICATION FOR REROOFING
1. JOB ADDRESS; _
2. TYPE OP BUILDING: RESIDENTIAL X COMMERCIAL _ ^
3. ROOF SLOPE: RUSE f inches In 12 Inches
4. NUMBBR OF EXISTING ROOF COVERING (circle one) ^T>2 3 |(
5. TYPE OF EXISTING ROOF COVERING Shake- SHEATHING V£-
*6. NEW ROOF MATERIAL ^ CLASS W^ WEIGHT PER SQUARE
7. tiUMBER OF SQUARES / "7
8. TRADE NAME fel\<{ft»g.^ Yg MANUFACTURE
9. ROOF SYSTEM LISTING UL Nf>. ^7^0 ICBO No.
10. IS THE EXISTING STRUCTURAL DESIGN SUFFICIENT TO SUSTAIN THE
WEIGHT OF THE PROPOSED ROOF? /YES) NO
AH roof coverings an> required to b« CLASS A, Combust)bl« roof coverings
of any type or classification are prohibited.
I understand ths following inspections are required: -/;,
1. Tear Ofl/Pra-fnspectlon prior to install new roof covering.
2. Final Inspection
I agree to provide a ladder extending at leaat 2 rungs above the roof for
Inspection.
Pate
Contractor _ Owner _ )C Contractor Name
*6 • Rolled Roofing, Standard/Ute Tlla, Asphalt/Comp Fiberglass, BulH up,
Other.
City of Carlsbad Bldg Inspection Request
For: 07/06/2004
Permit# CB042473
Title: COX RES-1700SFSTD WEIGHT
Description:
Inspector Assignment: RB
1760 CAPE MAY PL
Lot 0
Type:MISC Sub Type: REROOF
Job Address:
Suite:
Location:
APPLICANT COX TIMOTHY L&ROSEMARY H
Owner: COX TIMOTHY L&ROSEMARY H
Remarks:
Phone: 7605193415
Inspector:
Total Time:Requested By: MIKE
Entered By: CHRISTINE
CD Description
15 Roof/Reroof
Act Comment
££_
Associated PCRs/CVs
Inspection History
Date Description Act Insp Comments
07/01/2004 15 Roof/Reroof CO RB SEE NOTICE ATTACHED
06/23/2004 15 Roof/Reroof CA RB NEED TO EXPOSE PORTION OF ROOF. COMPLETED W/OUT INSP.
(1106-H6)
City of Carlsbad Bldg Inspection Request
For: 07/01/2004
Permittf CB042473
Title: COX RES-1700SFSTD WEIGHT
Description:
Inspector Assignment: RB
Sub Type: REROOF
1760 CAPE MAY PL
Lot
Type: MISC
Job Address:
Suite:
Location:
APPLICANT COX TIMOTHY L&ROSEMARY H
Owner: COX TIMOTHY L&ROSEMARY H
Remarks: AM PLEASE
Phone: 7605193450
Inspector:
Total Time:
CD Description
15 Roof/Reroof
Act Comment
Requested By: MIKE
Entered By: CHRISTINE
Associated PCRs/CVs
Inspection History
Date Description Act Insp Comments
06/23/2004 15 Roof/Reroof CA RB NEED TO EXPOSE PORTION OF ROOF. COMPLETED W/OUT INSP.
(1106-H6)
g
CITY OF CARLSBAD
BUILDING DEPARTMENT
NOTICE (760) 602-2700
1635 FARADAY AVENUE
fi TIME
V LOCATION / / 6
v
".PERMIT NO. _
?2. /'& (^(T<r0^*dk44 S& £»^ J ~r ' * ' #£* t/^sLe, ¥ <&?#<
$
<
"ft.*2*^
0£S£^ S*Q VL*
^tjz&L^A-&^^_^__
FOR INSPECTION CALL (760) 602-2725. RE-INSPECTION FEE DUE?
FOR FURTHER INFORMATION, CONTACT
YES
*
BUILDING INSPEC
PHONE
CODE ENFORCEMENT OFFICER
STRUCTURAL CALCULATIONS FOR A REROOFING PROJECT
Location:
Owners:
"TIM
Contractor:
Engineer:
Burton S. Myers
P.O. Box 893219
Temecula, CA 92589 - 3219
(909) 325 - 8507
(619)421-4211
(909) 325 - 8506 Fax
Wiiirw.myorc cnginoGPMig.oein
RCE: 24928 Exp.12-31-05
The work vrjll nnnniflrf of removing the existing wa*4okike roof, down to the spaced
sheeting. Adding plywood sheeting ( or equal ), additional braces, rafters, and gusset
plates, if needed, and a new tile roof per the manufacturers recommendations.
-TILE
T2>P
= II SO
RooF
O -
LWE Roof
4-v i z. - "So
4-: 13. 4 ^
•^^•••'^c'"^'1^'"^^^'^'^^^:^
4- ~
TI-LE
mjji••^^s 7;-O
.,
=^ 5 U>.L>
ex .
THE -
JVLLouu-fvet_£ 5?AN)S
0
1 cr
.I|I
' ~
EOT
o.
10 \\
GENERAL CONDITIONS
1 . THE SOLE PURPOSE OF THESE STRUCTURAL CALCULATIONS IS TO
DETERMINE THE GENERAL CONDITIONS OF THE OVER ALL STRUCTURAL ROOF
SYSTEM AND TO DETERMINE WHETHER THE ROOF SYSTEM CAN STRUCTURALLY
SUPPORT THE INSTALLATION OF THE N^S££fiflBaSBS"ROOF MATERIALS.
2. THE INSPECTION PORTION OF THE CALCULATIONS WfliL UJlUgiBT OF
DETERMINING THE SIZE MEMBERS THAT ARE NEEDED TO SUPPORT THE NEW
ROOF SYSTEM. IN THOSE CASES WHERE THE EXISTING ROOF SYSTEM DOES NOT
MEET THE MINIMUM BUILDING CODE REQUIREMENTS, RECOMMENDATIONS
WILL BE MADE TO ADD ADDITIONAL BRACES. SUPPORTS OR OTHER
STRUCTURAL MEMBERS TO INCREASE THE VALUES OF THE ROOF SYSTEM.
3. THE INSPECTION IS GENERAL IN SCOPE, AND DOES NOT INVOLVE INSPECTING
EACH INDIVIDUAL MEMBER.
4. THE INSPECTION DOES NOT INVOLVE LOOKING FOR DAMAGE CAUSED BY
TERMITES, DRYROT, OR OTHER SOURCES.
5. DURING THE COURSE OF THIS INSPECTION, CERTAIN AREAS U*
•MAY NOT DD ACCEOOIDLE. TIIQOC AREAO OIIOULD DEODOEKVLiD Ai'iiik iilTT
6. PLOT PLAN - THE PURPOSE OF THIS SKETCH IS TO SHOW THE OUTLINE OF
ALL THE STRUCTURES WHICH WERE EVALUATED, AND WHERE THE TYPI
ROOF SECTIONS WERE OBSERVED IN THE STRUCTURE. ALL DIMENSION
APPROXIMATE. IF THE OUTLINE OF THE STRUCTURE IS NOT SHOWN ON THIS
PLAN, THE STRUCTURE WAS NOT EVALUATED.
7. ROOF SHEETING - UNLESS SPECIFIED IN THE CALCULATIONS, THE ROOF
SHEETING WILL BE A MINIMUM 7/16" CDX PLYWOOD. 7/16" OSB (NER - 124) OR
EQUAL. THE PURPOSE OF THE ROOF SHEETING IS TO PROVIDE A NAILING
SURFACE FOR THE NEW TILE ROOF. THE ROOF SHEETING MAY BE APPLIED
DIRECTLY OVER THE EXISTING SPACED SHEETING. THE ROOF SHEETING
SHOULD BE ATTACHED WITH 8 D'S @ 6" O/C ALONG THE EDGES, AND @ 12" O/C
IN THE FIELD. THE CONTRACTOR SHOULD ATTEMPT TO NAIL THE ROOF
SHEETING TO THE EXISTING SPACED SHEETING WHERE POSSIBLE. INSTEAD OF
NAILS, STAPLES MAY BE USED PER TABLE 25-Q FOOTNOTE #9.
8. RAFTER JOISTS/GARAGE CEILING JOISTS - WHEN RAFTER JOISTS OR
GARAGE CEILING JOISTS ARE USED, THEY SHALL BE PLACED ON ALL RAFTERS,
NOT EVERY OTHER RAFTER. MAXIMUM SPACING FOR RAFTER JOISTS IS 24" O/C.
9. PURLINS - IF PURLINS ARE USED AS PART OF THE SUPPORT SYSTEM TO
REDUCE THE SPAN OF THE ROOF RAFTERS, THE FOLLOWING CONDITIONS MUST
BE MET.
A. PURLINS MUST BE EQUAL OR LARGER IN SI^E THAN THE RAFTERS
THEY SUPPORT.
B. THE MAXIMUM SPAN FOR 2x4 PURLINS SHALL BE 4 FEET.
C. THE MAXIMUM SPAN FOR THE 2 x 6 OR LARGER PURLINS SHALL BE 6
FEET.
THE STRUTS WHICH SUPPORT THE PURLINS AND CARRY THE LOADS TO BEARING
WALLS, SHALL BE A MINIMUM SIZE OF 2 x 4, AND THE UNBRACED LENGTH
SHALL NOT EXCEED 8 FEET.
10. THIS HOUSE WAS MEASURED AND INSPECTED UNDER MY DIRECTION TO
DETERMINE THE TYPE AND SIZE OF THE STRUCTURAL MEMBERS (COUNTY OF
SAN DIEGO).
\ 1. THIS ENGINEERING REPORT (INSPECTION AND CALCULATIONS) IS
PRIMARILY CONCERNED WITH THE ROOF SYSTEM. IT HAS TO BE ASSUMED
THAT THE VERTICAL STRUCTURAL SUPPORT MEMBERS AND THE FOUNDATION
SYSTEM WAS ORIGINALLY DESIGNED AND CONSTRUCTED TO THE BUILDING
CODES AND ARE SUFFICIENT TO SUPPORT THE ROOF SYSTEM.
12. WHENEVER THE ROOF SYSTEM HAS BEEN DETERMINED BY RAFTER TAILS
(REFERRED TO IN THE SECTION DRAWINGS), THE CONTRACTOR IS RESPONSIBLE
TO VERIFY THE SIZE AND SPACING OF THESE RAFTERS, AFTER THE ROOF IS
REMOVED.
13. THE CITY OF SAN*DIEGO REQUIRES THAT CODE APPROVED SMOKE
DETECTORS BE INSTALLED WHEN A REPAIR OR ALTERATION IS MADE TO A
RESIDENTIAL UNIT WHICH EXCEED $1,000.00. A CODE APPROVED SMOKE
DETECTOR IS REQUIRED TO BE INSTALLED IN EACH SLEEPING ROOM AND AT A
POINT CENTRALLY LOCATED IN THE CORRIDOR OR AREA GIVING ACCESS TO
EACH SEPARATE SLEEPING AREA (SECTION 1210 - UNIFORM BUILDING CODE