HomeMy WebLinkAbout1760 Yada Pl; ; CBRA2018-0055; PermitPermit
Print Date: 01/30/2020
Job Address:
{City of
Carlsbad
Permit No: CBRA2018-0055
Permit Type:
Parcel No:
1760 Vada Pl
BLDG-Associated Permit Resi
1562205900
Work Class:
Lot#:
Single Family Detached
6
Status:
Applied:
Closed -Finaled
03/13/2018
06/27/2019 Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
$614,492.64
1
5.00
VADA FARM
Reference #: DEV02058
Construction Type: VB
Bathrooms: 4.50
Orig. Plan Check#: PC2017-0048
Plan Check#:
Issued:
Permit
Finaled:
Inspector: MColl
Final
Inspection: 1/30/2020 9:48:15AM
Description: VADA FARM: PHASE 2 // LOT 6 // PLAN 3CR // 3,809 SF// 175 SF PATIO// 689 SF GARAGE// 128 SF PORCH
Applicant: Owner:
MARY NETTLES
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-2829
TRUST VADA FAMILY TRUST 03-12-90
1835 Buena Vista Way
CARLSBAD,CA 92008
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION
MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PARK IN-LIEU FEES SF DETACHED & DUPLEX: NW
PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL
PUBLIC FACILITIES FEES -outside CFD
SB1473 GREEN BUILDING STATE STANDARDS FEE
SDCWA SYSTEM CAPACITY CHARGE 3/4" Displacement
SEWER CONNECTION FEE (General Capacity all areas)
STRONG MOTION-RESIDENTIAL
SWPPP INSPECTION FEE TIER 1-Medium BLDG
SWPPP PLAN REVIEW FEE TIER 1-MEDIUM
TRAFFIC IMPACT Residential Single Fam. Outside CFD
WATER METER FEE 1" Displacement (P)
WATER SERVICE CONNECTION FEE 3/4" DISPLACEMENT (P)
WATER TREATMENT CAPACITY CHARGE 3/4" Displacement
Total Fees: $50,235.13 Total Payments To Date: $50,235.13
Contractor:
CALIFORNIA WEST CONSTRUCTION INC
5927 Priestly Dr, 110
Carlsbad, CA 92008-8800
760-918-6768
Balance Due: $0.00
$2,382.00
$1,534.01
$96.00
$170.00
$110.00
$7,649.00
$224.00
$21,507.24
$25.00
$5,267.00
$960.00
$79.88
$246.00
$56.00
$3,390.00
$282.00
$6,111.00
$146.00
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0055)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 06/30/2020 Address:
IVR Number: 10091
Scheduled
Date
Actual Start Date Inspection Type Inspection No.
BLDG-18 Exterior 110328-2019
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-23
Gas/Test/Repairs
110329-2019
Checklist Item
BLDG-Building Deficiency
12/16/2019 12/16/2019 BLDG-18 Exterior 113825-2019
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
01/02/2020 01/02/2020 BLDG-18 Exterior 115150-2019
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
01/03/2020 01/03/2020 BLDG-Electric
Meter Release
115253-2020
Checklist Item
BLDG-Building Deficiency
BLDG-Gas Meter
Release
115254-2020
01/30/2020 01/30/2020 BLDG-Final
Inspection
January 30, 2020
Checklist Item
BLDG-Building Deficiency
117831-2020
Checklist Item
BLDG-Building Deficiency
BLDG-Plumbing Final
BLDG-Mechanical Final
BLDG-Structural Final
BLDG-Electrical Final
Inspection Status Primary Inspector
Passed Michael Collins
COMMENTS
Passed Michael Collins
COMMENTS
Cancelled Michael Collins
COMMENTS
Cancelled per contractor
Passed Michael Collins
COMMENTS
Rear slider
Cancelled per contractor.
Passed Michael Collins
COMMENTS
EMR emailed to SDGE
Passed Michael Collins
COMMENTS
GMR emailed to SDGE
Passed Michael Collins
COMMENTS
TRUST VADA FAMILY TRUST
03-12-90
1760 Vada Pl
Carlsbad, CA 92008
Reinspection Complete
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Complete
Passed
No
Complete
Passed
Yes
No
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Yes
Yes
Yes
Yes
Page 3 of 3
---·· ·····-·--------
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0055)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner: TRUST YADA FAMILY TRUST
03-12-90
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 06/30/2020 Address: 1760 Yada Pl
IVR Number: 10091 Carlsbad, CA 92008
Scheduled Actual Inspection Type Inspection No. Inspection Status Primary Inspector Reinspection Complete
Date Start Date
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Prelim insulation/shear at exterior siding Yes
locations
10/28/2019 10/28/2019 BLDG-24 109087-2019 Passed Michael Collins Complete
Rough/To pout
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-27 Shower 109160-2019 Passed Michael Collins Complete
Pan/Tubs
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
10/29/2019 10/2912019 BLDG-84 Rough 109091-2019 Passed Michael Collins Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-24 Rough-Topout Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
11101/2019 11/01/2019 BLDG-16 Insulation 109534-2019 Passed LukeStomo Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency No
11/07/2019 11/07/2019 BLDG-82 Drywall, 110178-2019 Failed Michael Collins Reinspection Complete
Exterior Lath, Gas
Test, Hot Mop
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Not ready No
BLDG-17 Interior Lath-Drywall No
BLDG-18 Exterior Lath and No
Drywall
BLDG-23 Gas-Test-Repairs No
11/08/2019 11/0812019 BLOG-17 Interior 110330-2019 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Yes
January 30, 2020 Page 2 of 3
-·------·~·
PERMIT INSPECTION HISTORY REPORT (CBRA2018-0055)
Permit Type: BLDG-Associated Permit Residential Application Date: 03/13/2018 Owner:
Work Class: Single Family Detached Issue Date: 06/27/2019 Subdivision:
Status: Closed -Finaled Expiration Date: 06/30/2020 Address:
IVR Number: 10091
Scheduled
Date
Actual
Start Date Inspection Type Inspection No.
07/03/2019 07/03/2019 BLDG-SW-Pre-Con 096537-2019
Checklist Item
BLDG-Building Deficiency
07/18/2019 07/18/2019 BLDG-21
Underground/Unde
rfloor Plumbing
098015-2019
Checklist Item
BLDG-Building Deficiency
BLDG-22
Sewer/Water
Service
098014-2019
Checklist Item
BLDG-Building Deficiency
07/30/2019 07/30/2019 BLDG-11
Foundation/Ftg/Pier
s (Rebar)
099082-2019
Checklist Item
BLDG-Building Deficiency
08/23/2019 08/23/2019 BLDG-14
Frame/Steel/Boltin
g/Welding (Decks)
101817-2019
Checklist Item
BLDG-Building Deficiency
09/19/2019 09/19/2019 BLDG-15 104618-2019
Roof/ReRoof (Patio)
Checklist Item
BLDG-Building Deficiency
10/01/2019 10/01/2019 BLDG-13 Shear
Panels/HD (ok to
wrap)
106076-2019
Checklist Item
BLDG-Building Deficiency
10/17/2019 10/17/2019 BLDG-13 Shear
Panels/HO (ok to
wrap)
January 30, 2020
107858-2019
Inspection Status Primary Inspector
Passed Michael Collins
COMMENTS
Passed Michael Collins
COMMENTS
Waste to POC
Passed Michael Collins
COMMENTS
Waste to POC
Passed Michael Collins
COMMENTS
Ufer in place
Partial Pass Paul York
COMMENTS
Passed Michael Collins
COMMENTS
Partial Pass Michael Collins
COMMENTS
Prelim insulation/shear at exterior siding
locations
Passed Peter Dreibelbis
TRUST YADA FAMILY TRUST
03-12-90
1760 Yada Pl
Carlsbad, CA 92008
Reinspection Complete
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Passed
Yes
Reinspection Incomplete
Passed
Yes
Complete
Page 1 of 3
RECORD COPY A ~ CITY OJ
CARLSBAD
Building Division INSPECTION RECORD
CBRA2018-0055
1760YADA PL YADA FARM: PHASE 211 LOT 61/ PLAN 3CR II 3,809 SF II
175 SF PATIO 11689 SF GARAGE I/ 128 SF PORCH
0 INSPECTION RECORD CARD WITH APPROVED
ANS MUST BE KEPT ON THE JOB
lifCALL BEFORE 3:00 pm FOR NEXT WORK DAY INSPECTION
0 FOR BUILDING INSPECTION CALL: 760-602-2725
DEV02058
PC2017-0048
1562205900
4/18/2018
OR GO TO: www.Carfsbadca.gov/Bulldlnq AND CLICK ON
"Request Inspection" -. CBRA2018-0055
DATE: (.Q -;;i. 'l-~ I
If "YES'' is checked below that Division's approval is required rior to rg~_e?ti_rig a Final Building Inspection. If you have any questions
please call the applicable divisions at the phone numbers provided below. After all required approvals are signed off-fax to
760-602-8560. email to .IJl_(l_g{11s1-!_e_ct_i_9.ryS<r~~.ll?.-lli1~d_£~_,g_9y or bring in a COPY of this card to: 1635 Faraday Ave., Carlsbad.
IF MARKED "YES", IT IS REQUIRED PRIOR TO ANY CONSTRUCTION
STORM WATER PRECON MEETING REQUIRED 760-602-2725 Allow 24 hours
IF MARKED "YES", APPROVAL REQUIRED PRIOR TO REQUESTING BUILDING
Fire Prevention 760-602-4660 Allow 48 hours
Planning/Landscape 760-944-8463 Allow 48 hours
CM&I (Engineering Jm:pc-ctionsJ 76~38-3891 cau before 2 pm
CODE; lt BUILDING CODE# ELECTRICAL
#31 □ ELECTRIC UNDERGROUND
#12 REINFORCED STEEL #34 ROUGH ELECTRIC/ EV CHARGER
#66 MASONRY PRE GROUT #33 LEC SERVICE #32OTEMPORARY
□ GROUT □ WALL DRAINS #35 PHOTO VOLTAIC
\, TILT PANELS #38 SIGNS
#11 POUR STRIPS -----------1-----+-----l BLDG-FINAL
#11 COLUMN FOOTINGS CODE :tt MECHANICAL
#14 SUBFRAME □ FLOOR □ CEILING #41 UNDERGROUND DUCTS & PIPING
#15 ROOF SHEATHING #44 0 DUCT & PLENUM □ REF. PIPING
#13 EXT. SHEAR PANELS #43 HEAT-AIR COND. SYSTEMS
#16 INSULATION BLDG-FINAL
#18 EXIERIOR LATH
#17 INTERIOR LATH & DRYWALL
#82 DRYWALL,EXTLATH, GAS TES 117,18,23)
#83 ROOF SHEATING, EXT SHEAR (13,15)
#84 FRAME ROUGH COMBO (14,24,34,44)
#27
#23 A/S UNDERGROUND VISUAL
#25 WATER HEATER A/S UNDERGROUND HYDRO
#28 SOLAR WATER A/S UNDERGROUND FWSH
BLDG-FINAL A/S OVERHEAD VISUAL
CODE! 1f POOLS Date Ins ector A/S OVERHEAD HYDROSTATIC
#51 POOL EXCAV / STEEL A/S FINAL
#52 PLUMBING F/AROUGH·IN
#53 ELEC /CONDUIT/WIRING F/AFINAL
EQUIPOTENTIAL BONO FIXED EXllNGUISHING SYSTEM ROUGH-IN
;-,< PREPLASTER/ FENCE/ ALARMS FIXED EXTING SYSTEM HYDROSTATIC TEST
#57 GUNITE FIXED EXTINGUISHING SYSTEM FINAL
BLDG-FINAL MEDICAL GAS PRESSURE TEST
MEDICAL GAS FINAL
REV9!17
Date
Date
Date
COPY OF CARO
REQUIRED
Ins actor
Ins ector
Ins
SEE BACK FOR SPECIAL NOTES
r
GEOSOILS, INC. W.O.: 73TT-C-SC ------------Geotechnical-Coastal-G~ -Environmental DATE: 07/09/19 -------------NAME: TODD ------------HOURS: 2 ------------
FOOTING TRENCH OBSERVATION SUMMARY
CLIENT NAME: CAL-WEST PROJECT NAME: _____ Y:.;_A_;;;D:...A_;_ ___ _
LOCATIONfTRACT: __________ _;:B:.::U:.::E::_:N;_;Ac.:V.:.:IS::_:Tc..A:...A.::.Nc:D:...V:.:.A.=L=L=EY:.c,c.:C::.A.::.R:=L.::.SB:cA_;;;D:..:,_:Cc.A:=Llc.F.:... _________ _
UNIT/PHASE/LOTS: _____________ _:_PHc::A..::S:.:E::_:2:_L:.:O:_T:..:S:..:3:..:.4.:.:•:::5,:::6,:...10:..:•_:&:...1c.:1 ____________ _
REFERENCED GEOTECHNICAL REPORT:
OBSERVATION SUMMARY
TG INITIALS
07109119 DATE
TG INITIALS
07/09119 DATE
TG INITIALS
07109/19 DATE
TG INITIALS
07/09/19 DATE
A representative of GeoSolls, Inc. observed on site soil and footing conditions. Soil conditions in the trench
are generally tree of loose soil and debris, non-yielding and uniform, and plumb; and are In general
conformance with those indicated in the geotechnical report.
A representative of GeoSoils, Inc. observed and reviewed footing excavation depth/width. Footing
excavations generally extend to proper depth and bearing strata, and are In general conformance with
recommendations of the geotechnical report.
A representative of GeoSoils, Inc. reviewed footing setbacks from slope face (if appllcable). The setback was
in general accordance with the recommendations of the geotechnical report.
FOLLOW NOTES BELOW
NOTES TO SUPERINTENDENT/FOREMAN
1. Footing excavations should be deaned of loose debris and thoroughly moistened just prior to placing concrete.
2. Based on expansion potential of underlying soils, presoaking of soil below slabs may be recommended. Consult the
geotechnical report for presoaklng recommendations. We note that clayey soils may take an extended period time for
such, and the contractor should schedule accordingly.
3. In the event of a site change subsequent to our footing obseivation and prior to concrete placement (i.e. heavy rain, etc.),
we should be contacted to perform additional site observations and/or testing.
4. This memo does not confirm the minimum footing dimension as required by the project structural engineer's design, if
different from the geotechnical report.
NOTES TO BUILDING INSPECTOR
Soll compaction test results, as well as depth of fill, relative compaction, bearing values, corrosivity, and soil expansion index test results are
contained In the As-Graded Geotechnical or Final Compaction Report provided at the completion of grading.
DIGITAL DELIVERY -JIM HALL
Representative of Geo8oils, Inc.
·--·-------·~···------
Construction Testing & Engineering, Inc.
Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying
FINAL REPORT FOR SPECIAL INSPECTION & MATERIALS TESTING
December 11, 20 I 9
City Of Carlsbad
Building Inspection Department
1635 Faraday Avenue
Carlsbad, CA 92009
CTE Project No. I0-15086T
SUBJECT: SATISFACTORY COMPLETION OF WORK REQUIRING SPECIAL
INSPECTION PERFORMED UNDER PERMIT NUMBER:
Lot 3 · 1765 Yada Pl,
Lot 4 · 1795 Yada Pl
Lot 5 · 1790 Yada Pl
Lot 6 • 1760 Yada Pl
Lot 10-I 737 Buena Vista Wy
Lot I J. 1745 Buena Vista Wy
Permit# CBRA2018-0052
Permit# CBRA2018-0053
Permit# CBRA2018-0054
Permit# CBRA2018-0055
Permit# CBRA2018-0058
Permit# CBRA2018-0059
PROJECT ADDRESS: 1835 Buena Vista Way, Carlsbad, California (Phase 2)
I declare under penalty of perjury that, to the best of my knowledge, all of the work
requiring special inspection and materials testing of post-tension reinforcing, post-tension
concrete, reinforcing steel, shear panel framing inspection, concrete, and post stressing
operations has been completed. The inspected work for the structure constructed under
the subject permit is in conformance with the approved plans, the inspection and
observation program and other construction documents, and the applicable workmanship
provisions of the applicable building code. Executed on this eleventh day of December
2019.
TESTING LABORATORY OR SPECIAL INSPECTION AGENCY:
CONSTRUCTION TESTING & ENGINEERING, INC.
1441 MONTIEL ROAD SUITE 115
ESCONDIDO, CA 92026
RESPONSIBLE MANAGING ENGINEER OF THE TESTING LABORATORY OR
SPECIAL INSPECTION AGENCY:
Daniel T. Math
State of California Registration Number: 61013
Expiration Date: 12/31/20
SIGNATURE: __ ~--·~~=/~-----
1441 Montiel Road, Suite 115 Escondido, CA 92026 I Ph (760) 7464955 I Fax (760) 746-9806 I www.cte-inc.net
Construction Testing & Engineering, Inc.
Inspection I Tesling I Geolechnical I Environmental & Construction Engineenng I Civil Engineenng I Surveying
INSPECTION REPORT PAGE _1 __ OF _1 _
GTE JOB NO. 10-14654 ------
REPORTNO.
PROJECT NAME Had a Family Farm subdivision INSPECTION MATERIAL IDENTIFICATION
ADDRESS 121835 Buena Vista Way
Carlsbad. ca
ARCHITECT
ENGINEER
CONTRACTOR
OTHER
JD
California West
INSPECTION DATE 29July2019 ------------
PLAN FILE/OTHER
BLDG. PERMIT/OTHER See below ----------
□
li1'I
□
~
□
□
□
□
□
CONCRETE CONG. MIX NO. & lb/in2
REINF. STEEL GROUT MIX NO. & lb/in2
MASONRY MORT AR TYPE & lb/in2
P.T. CONCRETE REINF. STEEL GR/SIZE
FIELD WELDING STRUCTURAL STEEL
SHOP WELDING HIGH-STRENGTH BOLT
BATCH PLANT MASONRY BLOCK
EXP.ANCHOR OTHER
OTHER
MATERIAL SAMPLING
0 CONCRETE O MORTAR O GROUT 0 FIREPROOFING O MASONRY BLOCK
0 REINFORCING STEEL O STRUCTURAL STEEL 0 BOLTS O OTHER
INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS
PLEASE NOTE ANY RE-INSPECTION, TESTING OR OTHER PROJECT ISSUES.
Performed final rebar and PT inspection for lots #3. 4. 5 and 6. All rebar checked for size, grade, lap, placement, clearance and coverage.
All PT tendons checked for count, placement and drape. All hold downs placed per plans. All work complies with page PT1 of the
approved plans. All trash and non structural material to be removed from the pour area prior to concrete placement.
Lot. Address
Lot 3 -1765 Vada Pl, Cartsbad, ca.
Lot 4 -1795 Yada Pl, Carlsbad, ca.
Lot 5 -1790 Yada Pl, Carlsbad, ca.
Lot 6 -1760 Vada Pl, Carlsbad, Ca.
Permit#
CBRA2018-0052
CBRA2018-0053
CBRA2018-0054
CBRA2018-0055
Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications.
PRINTED NAME M.G.Sulham
CERTIFICATION NO. 5281716 / 5D1026 -------------SIGNATURE~
1441 Montiel Road. Suite 115 I Escondido. CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net
b~A,lnc.
land planning, civil engineering, surveying
July 29, 2019
W.O, 944-1289-600
Mr. Tim Frazee
CITY OF CARLSBAD,
Building Inspection Division
1635 Faraday Avenue
Carlsbad, CA 92008
ROD BRADLEY, Urban Planner
RONALD L. HOLLOWAY, Civil Engineer
RE: BUILDING FORM VERIFICATION FOR LOTS 3, 4, S, 6, 10 & 11 OF THE
YADA FAMILY FARM SUBDMSION, CT 15-11
Dear Mr. Frazee:
This letter is to attest that BHA, Inc. has staked the locations for the house construction on the
above-mentioned lots. We have checked the locations of the building forms of the proposed
houses and found the horizontal and vertical locations to conform to the grading plans
prepared by our office.
If you have any questions regarding this matter, please contact our office.
Sincerely,
~'W
Ronald L. Holloway
Senior Vice President
RCE29271
cc: Jim Hall-California West Communities
K:\Civil 3D\1289\PROD\Survey\Pad-Fonn Certs\forms\CT 15-1 l_Lots 3,4,5,6,10,11 bldg-form-vcrification.wpd
5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-7780
~~~~ W.0 .# 7377-C-SC
~~?~!~· MEMO DATE: 07/29/19
NAME: TODD
ChlA~I•...__. • ~ • eu.:. ... • Ea,i,,i,,_.-~ HOURS: 3.5
CLIENT CAL-WEST TRACT YADA LOCATION CARLSBAD
SUPER JIM CONTRACTOR GB
GSI ON SITE AT CLIENT'S REQUEST TO OBSERVE FOOTING EXCAVATIONS ON LOTS 3,4,5,6,10. AND 11.
FOOTINGS ARE EXCAVATED INTO SUITABLE BEARING SOIL.
WE OBSERVED SEWER CONNECTION TRENCHES WHERE THEY CROSS THE FOOTING EXCAVATION IN A LOOSE
AND UNCOMPACTED STATE. CONTRACTOR MAY RECTIFY BY:
1. COMPACTING THE SOIL
2. REMOVING LOOSE SOIL AND PLACING ADDITIONAL CONCRETE [ WRAP PIPE TO PREVENT DIRECT CONTACT]
3. IF UNABLE TO PERFORM# 1OR 2
ADD ADDITIONAL REBAR TEN FEET TO
EACH SIDE OF SEWER PIPE.
AREA OF UNCOMPACTED SOIL IN FOOTING EXCAVATION
ON ALL LOTS.
GeoSoils, Inc.
BY: ___ TBG_7/29/20 __ _
PAGE: 1 OF 1