Loading...
HomeMy WebLinkAbout1773 BLACKBIRD CIR; ; CB163395; PermitCity of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Plumbing/Mechanical/Electrical (PME) Permit 09-01-2016 Permit No: CB 163395 Building Inspection Request Line (760) 602-2725 Job Address: Permit Type: 1773 BLACKBIRD CR CBAD PME Status: Parcel No: 2156023800 Lot#: 0 Applied: Reference#: PC#: Project Title· Applicant: LINDWALL; ADD AIC PREPLUMBED REPLACE FURNACE THOMPSON HEATING & AIR 1980 PEACOCK BLVD OCEANSIDE CA 92056 760-471-5800 Plumbing Fees Electrical Fees Mechanical Fees Other PME Fees TOTAL PERMIT FEES Entered By: Plan Approved: Issued: Inspect Area: Owner: LINDWALL FAMILY TRUST 07-03-03 1773 BLACKBIRD CIR CARLSBAD CA 92011 ISSUED 09/01/2016 EH 09/01/2016 09/01/2016 $0.00 $0.00 $163.00 $0.00 $163.00 Total Fees: $163.00 Total Payments To Date: $163.00 Balance Due: Inspector: FINAL APPROVAL il•~?J-11 Date: Clearance: $0.00 N011CE: Rease take 1\0-rfCE that awuva of y:ur pqoct irduc:Es tre "lrrp:::sitioo" dfees, OO:::Jicatia-s, resavatjms, cr cthff exa::tia-s hffeafta-cDIEdiv9y referred to as ''feeslexa::tirns." Yoo rave 00 days fran the date this panit v.a5 iSSlX:ld to pn:;tESI: irrp:::sitioo ci these feeslexaJ:ims. If yoo p-ct.est ti"'Em, JUJ rrust fdiON the pd:est pr.:x:::edu"es set forth in G:NarrrJ:rt c::cx:e S::d:im Ero20(a), ard file the put ESt erd arl)l d:l"ff rEQ..ired infoomtim \1\ith the Oty ~ fcr ~ng in a::cadarce Wth Carisba:.i rvllnidpal O:x.E Sedioo 3.32 030_ Fa lure to ti~y fdlo.vthat pu:::Edure \Mil OOr any sul::sEq....ent legal cd:ion to attock, re...-ie..rv, set aside, I,Qd, cr anrU treir tfllXSilion Yru are hereby FLR1l-ER I\011RED that yar nght to pd.est the sp:dfied fres/exad.iOlS IX.ES NOT APPLY tov.ata-en! seAer cx:offiioo fees ard capa]ty ~-ra piEJTlr-.g, za1ng, ga:irg cr ether sirrilar apf:)iartim p-ocesswg cr sa-vice fres in CD'"V""e:,jim Wth ths p-qect f\m CO::S IT .Afft. Y to any feESiexa:tims ofv.hdl \rUL have O"e'v"iM t:een dven a NOTlCE Slrrilar to tlis cr as to v.hdl tre statute of linitatims ras crevicuslv otho.3:\r\.ise exrire:l. THF FOLLOWING APPfWVALS RLQUIRL 0 PRIOR TO PERMIT ISSUANCl PI ANNIN(; LNG IN[ l RING BUILDING (City of Carlsbad Building Permit Application 1635 Faraday Ave. Carlsbad, CA 92008 Ph 760-602-2719 Fax 760-602-8558 ema1l build1ng@carlsbadca.gov www.carlsbadca.gov Plan Check N()·C6 \ v3'Yi s JOB ADDRESS DESCRIPTION OF WORK: 1773 BLACKBIRD CIR I""" _______________ r I'"''''' r·"'·""-- lnclude Square Feet of Affected Area(s) SUITE#/ SPACE II/ UNIT# Est. Value Plan Ck. Deposit D;t~0\ I I u' ADD AJC, PREPLUMBED, REPLACE FURANCE SWPPP EXISTING USE PROPOSED USE FIR[e>Lt<:E AlP CONDITimJING FIR~ SPRINKLeRS Yss[}t "oD YCS0No0 YESDNoD APPLICANT NAME THOMPSON HEATIN(3_f\NI)f\IR CONDITIONINSi JOHN AND DEANNE LINDWALL Pf!nary __ C()_Il!<J!:t .--:ITY OCEANSIDE 92056 f'AX 7608427630 -~-- CONTACT@THACC.NET 177~T~LACKBIRD ~,;,}R~_ CA -+=~-CARLSBAD PIIClNE 92011 Fr-.1.!\.IL 7605180753 JLINDWALL@YAHOO.COM I DESIGN PROFESSIONAL CONTRACTOR BUS. NAME Thomp_son Heatina and Air Gonditionina 1980 Peacock Blvd. Ste. C :O.U'JRESS I CITV STATF Z.P ?le> Oceanside CA 92056 PH:J~E FA.\ PHONE FAx 760-842-7630 U/AII I ~/;\II contact@thacc.net Worker<;' Comp~nsat1on Declaration I lmteUI ,J!/..-.rlli [ii-'<il'r i'r'i!.!i!·,·, :/ !'f-'l,iiiiJ' ,_,,~,,. 11/ l.lil' h•i1, 'i\i!h' ,_~,., i.l.r.· .. r" ,,,", D I have and will m~1111ain a certifrcatr of cono.t'nl to self-insure 'l•l work~r< crw1penc-a112~ as pr~v ded t,y ·.r-ct1011 3/JO ~;I lw~ I c~u::r (.:.•rJe fe-r the pertcr1nance o' th0 ·NU'k for w~1ch 1h1c peTI 1 i·; is·,>ued [{] I have and will marntaln work0rs· compen'>ation. as 'eq.;rred bv :;e;;tiorr J~80 8t :~e I ?.h~r C::cae 'or :··e peri:JII'lJnce 0t ·.~e WfJ'k fur w'11ch lh·s perrnr1 1~ .:,s11ed My workers COfllp€nsa:.on rn~IHrli'CP cw·rer and po rcy eu·nber are rnc"rrce c~· NORGUARD INSURNACE COMPANY ::culq \~ _ THWC700341 =x_prra:orr Da:e _ 4/712017 Tho s;;ctl~'". "eed n~t 0e cc-:npiPtec f t1c pUll' I: IS 'or one hundred rJ8:1nrs ·:S' OO:r or l»ss tJ Certificate of Exernpuon: I (c;ct1h1 tr,it 1° the f'PrormrcP. ot ·110 wcr~ for whr,~h th1.o; perfllr1 rs :ssuerJ -"a'l --ut e·nplc.y any per:;r:-n 111 cr--y rra--ner so as to neccne subJec: tu t1u ·,·V·Akus Cornper'satron L<1ws o' Calrfornra WARNING: Failure 10 secure workers' compensation l.ovel ag~ is unlawful, and o.h~ll o.Ubject an employer to crrmrnal penaltie'> ~nd civil fines up to one hundred thousand dollars (& 100,000), in addition to lhu cost of compensation. damages as provid~d fur in Section 3705 of the Labor code, inlere\t and attorney''> fee~. Ji5 CONTRACTOR SIGNATURE D 0 D I as owner o' the vopery Dr ·ny employees w1th wage.s as therr ,,~le cumpensatron wrll rh Hw w:; ~and the struclure rs flOt r~tended or oliered for sale (Sec , 044 ~us rrbs and Prcfessrons Code The Contracwr's Lrce"·se I aw doe,, "Ot aDp y I~· a~ owner of property who ~mid" or rrnproves thereon. ;1rrd who docs ~Wi' wor~ hrfllsel' Gr th-c-uglr hrs own efllployees. provided l~ra' such rfll~rovements ~re rmt rrl'endcc or Jf'ereo for ,;cw f however the b"1 drnJ or rmprovement rs sJrd wr:"rll c-ee year ot ~n1rp Ptrcn llle owner burloe• 'll·i·l "il'-IP the; ~uroerr oi vovrnq that _.,e erG no: Cuild Jr rmprov·e tor the pr..rpr,se of sdle) I as ow~er o+ lire pruperty am cxciUSI'Jely c:cn~ractr···g wr::1 trcense-j 2ontr:;c:orc. ·n :;ow;trrU tile pru;ect ·:Sec -~A~ lirdneso nnd Profess ons r:ode T "e :-:ontrdr:'sr s Lrcense Law does ··nt ;r;~p y tu c111 owner Jf plpH!y wl•o bu,lds or rn·pro1·es ._,·wecrr cmd c:~ntrac:_s 'or such IYOiecto wrt·r u:rr:r~uc-n.si lrcenstd r·ur~:,,-;·:· 1:: :·H~ CJntractor s L:::.ense La~,-, arr eter:-rpt ,;nc::u :ie~l10n Business 2n:J ;:role:.SI')nS ~:ode foe th c; WilSOn 1 pHsonally ~I an lc po-.'rd8 tl1e llldl0' ld00' ?.rd rrra:enals tor r:on'," .ctr::rr c)' thr PIDJOSCd voper:, r·nr::•er·rent DY rs o~:; 2 , r.ha-.-c have no'.j s gne:f arr ap~l cat1011 fer a br,rid1ng permrt for the voposcd ·1\·crk 3 I ha·J·J co~tracte~ '.'.'IHr tile '•_ll o·.v nq pt·rson ·:Inn~ :r' prov1rJe ·Ire :Hc-pr,sr•d construc!·(J -: rr-IIJ(Jp rr,1flr(· adcre:;s phor1e ~orwan~~,< 1.-:;err~e rrt.rrber) -1. I plan lrJ f•rDVI(]e rortrc-rh r:-1 ti1P ·Nor~ b· .. : I have "rrerJ the fc'lcwrrrr; oc•r;;crr tD coo'drn:tte suowv1SC ~-,,j pr::.v•.je the rrr(,JC'I work -:'rnslude na•ne address · ph::ne co~tr~c:cr:; l1ccn~e nurrher;· j I will prc-1· dP son•c of the wc-rk. t-:111 have contracted !h-rc•j) tile· tcdlowp·g pero;c-ns :u pruwk thv wcrf 1nd1ca1eci ill'(iuce rrarne dddress phone type of wo~K! Ji5 PROPERTY OWNFR SIGNATURE [{]AGENT DATE 8/31/16 ''lereby auth011~e rcpresental1ve of the C1ty of Ca~sb;yJ toe1ner Jpc:-•1 trc at'XJvP '''PI'ti:Y18C I .,J,L q:. N~;f\U:: I U ·?,.1:..\Jr:: ~~~D[M'\Jif-Y ;,JJ[l r<EEP H;\~\r!LESS TW CITY m CARl SBAC ;\G;\J,'ST AJ_ 11."'-Rit iTit:S ,jl)iJCME\JTS. COSTS Arm :::XP::':NSi::S 'N•11CI · ~/.'\Y I~J _q., Y II-. CUI,S:()._.r:::~,C::: :.~:1 -rc_ CJRAWI~,c; 01 THIS :'FRIVIT DS· I;\ '\r USH.:., per,-,.11 IS rcqured h excavat1ons cvw 5'0' dePo ;n:J dernolltlo•·, or cJnslrti•,'IIO' r} .Tr~.:L:rcs over :i ~:tv es 1n 'lc1ght CXPIRA IID~J Fvery perm1t 1~:sued tJy the Ru1ld1ng Offic1JI Jnder he :YOVISinrs of 1~·1:· by ll'"'l'_dllon ::md tcwmo 'lLII a1rd vo1d 1f the 01:1ldng or \Wit a1rthor.zed by :;uclr p2rmi~ IS no! cornf"renced Wlth-n 180 cays f'Dm ·he d;;te o: oL.cn p2rrn1t or rf tnr buildi1rg c-r w::;rk auttlllii?Cd ·'Jy •,1rd· p2WII 1·; a· a'l\' t1rne Jfter lire 1Wrk ~~ GJmme1rce'j fv a perrod nf < 80 da)'S (Scctlr-r· 1 ~JS 4 4 Unrform F:luild1rrg Code} A$ APPLICANT'S SIGNATURE DATE 8/31/16 Inspection List Permit#: CB163395 Type: PME Date Inspection Item 10/21/2016 43 AirCond/Furnace Set 10/21/2016 43 AirCond/Furnace Sel 10/21/2016 49 F1nal Mechan1cal 10/21/2016 49 F1nal Mechanical Monday, October 24, 2016 Inspector JW JW Act Rl AP Rl AP LINDWALL; ADD AIC PREPLUMBED REPLACE FURNACE Comments Page 1 of 1 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 1 of7) Project Name: Lindwall Enforcement Agency: City of Carlsbad Permit Number: on site Dwelling Address: 1773 Blackbird Cir City: Carlsbad Zip Code: A. General Information 01 Dwelling Unit Name Lindwall 02 Climate Zone 03 Dwelling Unit Total Conditioned Floor 1800 04 Number of Space Conditioning Area (ft2) Systems in this Dwelling Unit. 05 Certificate of Compliance Type Prescriptive alterations (CF1R-ALT) 06 Method used to Calculate HVAC Loads 07 Calculated Dwelling Unit Sensible This field or section is not applicable 08 Calculated Dwelling Unit Heating Load Cooling Load (Btuh) (Btu h) 09 Dwelling Unit Number of Bedrooms 4 MCH-Olb Space Conditioning Systems Ducts and Fans-Prescriptive Alterations B. Space Conditioning (SC) System Information 01 02 03 04 SC System SC System CFA served Is the SC Identification or Location or Area by this SC system a dueled Name Served System (ft2) system? System 1 house 1800 Yes Registration Number: 216-A0385180A-M0100002A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance 05 06 07 Installing a Installing new SC Installing more refrigerant system than 40 feet of containing component? components? ducts? Yes Yes No Registration Date/Time: 2016-10-14 071941 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 08 Installing entirely new duct system? No 92011 7 1 No tAp pI i cab I eEq u i p m entCh a ngeout This field or section is not applicable 09 10 Installing entirely new SC Alteration Type system? Altered space No conditioning system HERS Provider: CaiCERTS Report Generated: 2016-10-14 07:18:45 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans C. Space Conditioning (SC) System Alterations Compliance Information 01 02 03 04 OS 06 07 08 09 Heating Cooling System Altered Heating Minimum Altered Cooling Minimum Identification Heating Heating Efficiency Efficiency Cooling Cooling Efficiency Efficiency or Name System Type Component Type Value System Type Components Type Value All new All new System 1 Central gas heating AFUE 78 Central cooling SEER 13 furnace componen split AC components ts - D. Installed Heating Equipment Information 01 02 03 04 OS System Identification or Heating Efficiency Heating Unit Heating Unit Name Heating Efficiency Type Value Manufacturer Model Number System 1 AFUE 78 Trane TUD2B080A9V3V BB Notes: Registration Number: 216-A0385180A-M0100002A-OOOO Registration Date/Time: 2016-10-14 071941 CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MCH-01-E (Page 2 of7) 10 11 12 13 Central Fan Integrated New or (CFI) Required Replaced New Ventilation Thermostat Duct Duct System Type Length R-Value Status Setback LTE40Ft R6 Not a CFI system 06 07 Heating Unit serial Rated Heating Capacity, number Output (BTUH) 16302VEX1G 68000 HERS Provider: CaiCERTS Report Generated: 2016-10-14 07:18:45 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans E. Installed Cooling Equipment information 01 I 02 03 04 OS I 06 Condenser or Package Unit Condenser or Condenser or Condenser or System Identification Cooling Efficiency Cooling Efficiency Package Unit Package Unit Package Unit or Name Type Value System 1 SEER 14 Notes: F. Extension of Existing Duct System, Greater Than 40 Feet G. Installed Duct System information H. Installed Air Filter Device Information I. Air Filter Device Requirements Registration Number: 216-A0385180A-M0100002A-OOOO CA Building Energy Efficiency Standards-2013 Residential Compliance Manufacturer Model Number Serial Number Trane 4TIR7048A100 16115RXW2F OBA This section does not apply to this project. This section does not apply to this project. This section does not apply to this project. This section does not apply to this project. Registration Date/Time: 2016-10-14 07:19:41 Report Version: 2013 Rev L008 Schema Version: 2013.1.008 CFZR-MCH-01-E (Page 3 of7) 07 I 08 System Rated Cooling Condenser Rated Capacity at Design Nominal Capacity Conditions (BTUH) (ton) 48000 4 HERS Provider: CalCERTS Report Generated: 2016-10-14 07:18:45 CERTIFICATE OF INSTALLATION Space Conditioning Systems, Ducts, and Fans J. HERS Verification Requirements 01 02 03 04 MCH20 Exemption System SC System From Duct Duct Identification or Location or Area Leakage Leakage Name Served Requirements Test System 1 house No Yes exemptions Notes: Registration Number: 216-A0385180A-M0100002A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance 05 06 07 MCH21 MCH22 Exemption from Minimum R-Value for Ducts In Ducts Located AHU Fan Conditioned In Cond Space Efficacy Space Verification (W/cfm) No No No Exemption Registration Date/Time: 2016-10-14 071941 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 CF2R-MCH-01-E (Page4of7) 08 09 10 MCH23 MCH25 MCH28 AHU Airflow Rate Refrigerant Return Duct Design (elm/ton) Charge Table 150.0-C or D No No No HERS Provider: CalCERTS Report Generated: 2016-10-14 07:18:45 CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 5 of7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Heating Equipment 01 Equipment Efficiency: All heating equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency Regulations. 02 Controls: All unitary heating systems, including heat pumps, must be controlled by a setback thermostat. These thermostats must be capable of allowing the occupant to program the temperature set points for at least four different periods in 24 hours. See Sections 1SO.O(i), 110.2(b). 03 Sizing: Heating load calculations must be done on portions of the building served by new heating systems to prevent inadvertent undersizing or oversizing. See sections 1 150.0(h)1 and 2). 04 Furnace Temperature Rise: Central forced-air heating furnace installations must be configured to operate at or below the furnace manufacturer's maximum inlet-to-outlet temperature rise specification. See Section 1SO.O(h)4. OS Standby Losses and Pilot Lights: Fan-type central furnaces may not have a continuously burning pilot light. Section 110.5 and Section 110.2(d). Cooling Equipment Equipment Efficiency: All cooling equipment must meet the minimum efficiency requirements of Section 110.1 and Section 110.2(a) and the Appliance Efficiency 06 Regulations. 07 Refrigerant Line Insulation: All refrigerant line insulation in split system air conditioners and heat pumps must meet the R-value and protection requirements of Section 150.0(j)2 and 3, and Section 150.0(m)9. 08 Condensing Unit Location: Condensing units shall not be placed within five (5) feet of a dryer vent outlet. See Section 150.0(h)3A. 09 Sizing: Cooling load calculations must be done on portions of the building served by new cooling systems to prevent inadvertent undersizing or oversizing. See Section 150.0(h)1 and 2. Air Distribution System Ducts, Plenums and Fans 10 Insulation: In all cases, unless ducts are enclosed entirely in directly conditioned space, the minimum duct insulation value is R-6. Note that higher values may be required by the prescriptive or performance requirements. See Section 150.0(m)l. -- Registration Number: 216-A0385180A-M0100002A-OOOO CA Building Energy Efficiency Standards-· 2013 Residential Compliance ------ Registration Date/Time: 2016-10-14 0719:41 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-10-14 07:18:45 . ' • CERTIFICATE OF INSTALLATION CF2R-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 6 of7) K. Space Conditioning Systems, Ducts and Fans Mandatory Requirements and Additional Measures Note: Additional mandatory requirements from Section 150.0 that are not listed here may be applicable to some systems. These requirements may be applicable to only newly installed equipment or portions of the system that are altered. Existing equipment may be exempt from these requirements. Connections and Closures: All installed air-distribution system ducts and plenums must be, sealed and insulated to meet the requirements of CMC Sections 601.0, 11 602.0, 603.0, 604.0, 60S.O and ANSI/SMACNA-006-2006: Supply-air and return-air ducts and plenums must be insulated to a minimum installed level of R-6.0 or enclosed entirely in directly conditioned space as confirmed through field verification and diagnostic testing in accordance with the requirements of Reference Residential Appendix RA3.1.4.3.8. Heat Pump Thermostat 12 A thermostat shall be installed that meets the requirements of Section l10.2(b) and Section 110.2(c). 13 The thermostat shall be installed in accordance with the manufacturers published installation specifications 14 First stage of heating shall be assigned to heat pump heating. 15 Second stage back up heating shall be set to come on only when the indoor set temperature cannot be met. The responsible person signature on this compliance document affirms that all applicable requirements in this table have been met. Registration Number: 216-A0385180A-M0100002A-0000 CA Building Energy Efficiency Standards-2013 Residential Compliance Registration Date/Time: 2016·10-14 07:1941 Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 HERS Provider: CaiCERTS Report Generated: 2016-10-14 07:18:45 i CERTIFICATE OF INSTALLATION CFZR-MCH-01-E Space Conditioning Systems, Ducts, and Fans (Page 7 of 7) Documentation Author's Declaration Statement 1. I certify that this Certificate of Installation documentation is accurate and complete. Documentation Author Name: Documentation Author Signature: /}cwdt {]Jm;ui Garett Baird Company: Signature Date: THOMPSON HEATING AND AIR CONDITIONING 2016-10-14 07:19:41 Address: CEA/ HERS Certification Identification (if applicable): 2531 BRADLEY STREET City/State/Zip: Phone: OCEANSIDE CA 92056 760-4 71-5800 - Responsible Person's Declaration statement I certify the following under penalty of perjury, under the laws of the State of California: L The information provided on this Certificate of Installation is true and correct. 2 1 am eligible under Division 3 of the Business and Professions Code in the applicable classification to accept responsibility for the system design, construction, or installation of features, materials, components, or manufactured devices for the scope of work identified on this Certificate of Installation, and attest to the declarations in this statement {responsible builder/installer), otherwise I am an authorized representative of the responsible builder/installer. 3 The constructed or installed features, materials, components or manufactured devices (the installation) identified on this Certificate of Installation conforms to all applicable codes and regulations, and the installation conforms to the requirements given on the plans and specifications approved by the enforcement agency. 4. 1 reviewed a copy of the Certificate of Compliance approved by the enforcement agency that identifies the specific requirements for the scope of construction or installation identified on this Certificate of Installation, and I have ensured that the requirements that apply to the construction or installation have been met. 5. I will ensure that a registered copy of this Certificate of Installation shall be posted, or made available with the building permit(s) issued for the building, and made available to the enforcement agency for all applicable inspections. I understand that a registered copy of this Certificate of Installation is required to be included with the documentation the builder provides to the building owner at occupancy. Responsible Builder/Installer Name: Responsible Builder/Installer Signature: r--fjcwdf; (.Jjm;ui Garett Baird Company Name: (Installing Subcontractor or General Contractor or Builder/Owner) Position With Company (Title): THOMPSON HEATING AND AIR CONDITIONING owner Address: CSLB License: 2531 BRADLEY STREET 974400 City/State/Zip: Phone: I Date Signed: - OCEANSIDE CA 92056 760-471-5800 2016-10-14 07:19:41 Digitally signed by Ca/CERTS. This digital signature is provided in order to secure the content of this registered document, and in no way implies Registration Provider responsibility for the accuracy of the information Registration Number: 216-A0385180A-M0100002A-OOOO Registration Date/Time: 2016-10-14 07:19:41 HERS Provider: CalCERTS CA Building Energy Efficiency Standards-2013 Residential Compliance Report Version: 2013 Rev 1.008 Schema Version: 2013.1.008 Report Generated: 2016-10-14 07:18:45