HomeMy WebLinkAbout1774 COTTONWOOD AVE; ; CB082291; Permit12-30-2008
City of Carlsbad
1635 Faraday Av Carlsbad, CA 92008
Plumbing Permit Permit No: CB082291
Building Inspection Request Line (760) 602-2725
Job Address:
Permit Type:
Parcel No:
Reference #:
PC#:
Project Title:
Applicant:
ACG PLUMBING
3568 9TH ST 92078
760 295-3346
1774 COTTONWOOD AV CBAD
PLUM
2155033721 Lot#:
Construction Type:
SEAPORT HOA- REPLACE EXPOSED
GAS LINE FROM P/L TO HOUSE
0
NEW
Status:
Applied:
Entered By:
Plan Approved:
Issued:
Inspect Area:
ISSUED
12/30/2008
LSM
12/30/2008
12/30/2008
Owner:
COURTNEY CHRISTINA TRUST 04-07-05
1774 COTTONWOOD AVE
CARLSBAD CA 92011
Plumbing Issue Fee
Fixture or Trap
Building Sewer
Roof Drain
Install/Repair Water Line
Water Heater and/or Vent
Gas Piping System
Vacuum Breaker
Other Plumbing Fees
Master Drainage Fee
Sewer Fee
Additional Fees
0
0
0
0
0
1
0
$20.00
$0.00
$0.00
$0.00
$0.00
$0.00
$7.00
$0.00
$0.00
$0.00
$0.00
$0.00
TOTAL PERMIT FEES $27.00
Total Fees:$27.00 Total Payments To Date:$27.00 Balance Due:$0.00
ssssr
I
Inspector:
FINAL APPROVAL
Date:Clearance:
NOTICE: Please take NOTICE that approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this permit was issued to protest imposition of these fees/'exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired.
City of Carlsbad ^^
1635 Faraday Ave., Carlsbad, CA 92008 W[^^^
760-602-2717/2718/2719 ^^O^
Fax:760-602-8558 ^JfrS^
www.carlsbadca.gov ^VJ^ES^
Building Permit Application
JOB ADDRESS f\ \\ ^
CT/PROJECT* LOT* PHASE # # OF UNITS # BEDROOMS
g^ Plan Check No. Q& Ofr&S-Q )
ff Est. Value
r Plan Ck. Deposit
Date '^/3OJO& i^^r^
SUITE#/SPACE#/UNIT# APN
# BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
DESCRIPTION OF WORK: Include Square Feet of Affected Areafs)
EXISTING USE PROPOSED USE GARAGE (SF)
CONTACT NAME (If Different Font Applicant)
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
PROPERTY OWNER NAME «=:Co •Or»Y?~$' % \ /•N /\ / R 1 Q~> *
ADDRESS
CITY STATE ZIP
PHONE FAX
PATIOS (SF) DECKS (SF) FIREPLACE AIR CONDITIONING FIRE SPRINKLERS
YES D # NO D YES D NO D YES D NO D
APPLICANT NAME
ADDRESS
CITY STATE ZIP
PHONE FAX
EMAIL
CONTRACTOR BUS. NAME J\ f\ /• p>/ . . ISACe? HUMOtNV?
ADDRESS , » ^
3&L& <&• "Sf-
CSivxi 1^N2^^ SWE C* . Z'P^0 7^
PMONE FAX
EMAIL j EMAIL
ARCH/DESIGNER NAME & ADDRESS STATE LIC. # STATE LIC.# CUSS CITY BUS. LIC.#
(Sec. 7031.5 Business and Professions Code: An/ City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement that he islicensed pursuant to the provisions of the Contractor's License law {Chapter 9. commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt there from, and the basis for the alleged exemption. Any violation ofSection 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars {$500}j.
WORKERS' COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations:
C3 I have and will maintain a certificate of consent to sen-insure lor workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
[D I have and will maintain workers' compensation, as required by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co. Policy No. Expiration Date
> section need not be completed if the permit is for one hundred dollars ($100) or less.
Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
'California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensatlotfaamages as provided for in Section 3706 orthe Labor code, interest and attorney's fees.
DATE
OWNER-BUILDER DECLARATION
/ hereby affirm that I am exempt from Contractor's License Law for the following reason:
rj I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
Q I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractors) licensed pursuant to the Contractor's License Law).
D I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement, a Yes d No
2.1 (have / have not) signed an application for a building permit for the proposed work.
3.1 have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name / address / phone / contractors' license number):
5.1 will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work):
^PROPERTY OWNER SIGNATURE DATE
COMPLETE THIS SECTION FOR N O N - R E S I D E N T 1 A L BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Act? D Yes d No
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district? Q Yes Q No
Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? a Yes a No
IF ANY OF THE ANSWERS ARE YES, /
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec. 3097 (i) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the application and state that the above information is correct and that the information on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Carlsbad to enter upon the above mentioned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CfTY OF CARLSBAD
OSHA: An OSHA permit is required for excavations over 5'0' deep and demolition or construction of structures over 3 stories in height.
EXPIRATION: Every permit issued by tha-Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within
180 days from the date of such permit o/jr tne building or worir^uthorized tjysuch permit is puspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106.4.4 Uniform Building Code).
^APPLICANTS SIGNATURE
City of Carlsbad
December 10, 2009
CHRISTINA COURTNEY TRUST
1774 COTTONWOOD AV
CARLSBAD CA 92011
RE: BUILDING PERMIT EXPIRATION
PERMIT TYPE: GAS LINE
Building Department
Permit Number: CB082291
Issue Date: 12/30/2008
ADDRESS: 1774 COTTONWOOD AV
PLEASE CALL FOR AN INSPECTION IF WORK IS
COMPLETE
Our records indicate that your building permit will expire by limitation of time on 12/28/2009.
The provisions of UBC, Section 106.4.4 as amended by the Carlsbad Municipal Code state: "EXPIRATION.
Every permit issued by the Building Official under the provisions of this code shall expire by limitation and
become null and void if the building or work authorized by such permit is not commenced within 180 days from
the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work
is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three
calendar years from the issuance date of permit. Work shall be presumed to have commenced if the permittee has
obtained a required inspection approval of work authorized by the permit by the Building Official within 180
days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a
required inspection approval of work by the Building Official within each 180 day period upon the initial
commencement of work authorized by such permit.
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be
one-half the amount required for a new permit for such work, and provided that no changes have been made or
will be made in the original plans and specifications for such work, and provided further that such suspension or
abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall
pay a new permit fee.
Any person holding an unexpired permit may apply for an extension of the time within which work may
commence under that permit when the permittee is unable to commence work within the time period required by
this section for good and satisfactory reasons. The Building Official may extend the time for action by the
permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances
beyond the control of the permittee have prevented action from being taken. No permit shall be extended more
than once.
Please check below indicating your intentions and return this letter to us.
Project abandoned. A new permit will be obtained prior to commencing work.
No fee extension requested for 180 days, (attach a letter of explanation)
Renewal permit requested.
If the project has been completed and only a final inspection is needed, please call the inspection request line at
(760) 602-2725.
If you have any questions, please contact the Building Inspection Department at (760) 602-2700.
Christine Wauschek
Office Specialist
1635 Faraday Avenue • Carlsbad, CA 92OO8-7314 • (76O) 6O2-27OO • FAX (76O) 6O2-856O
City of Carlsbad
December 10,
ACG PLUMBING
3568 9TH ST
SAN MARCOS CA 92078
RE: BUILDING PERMIT EXPIRATION
PERMIT TYPE: GAS LINE
Building Department
Permit Number: CB082291
Issue Date: 12/30/2008
ADDRESS: 1774 COTTONWOOD AV
PLEASE CALL FOR AN INSPECTION IF WORK IS
COMPLETE
Our records indicate that your building permit will expire by limitation of time on 12/28/2009.
The provisions of UBC, Section 106.4.4 as amended by the Carlsbad Municipal Code state: "EXPIRATION.
Every permit issued by the Building Official under the provisions of this code shall expire by limitation and
become null and void if the building or work authorized by such permit is not commenced within 180 days from
the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work
is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three
calendar years from the issuance date of permit. Work shall be presumed to have commenced if the permittee has
obtained a required inspection approval of work authorized by the permit by the Building Official within 180
days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a
required inspection approval of work by the Building Official within each 180 day period upon the initial
commencement of work authorized by such permit.
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be
one-half the amount required for a new permit for such work, and provided that no changes have been made or
will be made in the original plans and specifications for such work, and provided further that such suspension or
abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall
pay a new permit fee.
Any person holding an unexpired permit may apply for an extension of the time within which work may
commence under that permit when the permittee is unable to commence work within the time period required by
this section for good and satisfactory reasons. The Building Official may extend the time for action by the
permittee for a period not exceeding 180 days on written request by the permittee showing that circumstances
beyond the control of the permittee have prevented action from being taken. No permit shall be extended more
than once.
Please check below indicating your intentions and return this letter to us.
Project abandoned. A new permit will be obtained prior to commencing work.
No fee extension requested for 180 days, (attach a letter of explanation)
Renewal permit requested.
If the project has been completed and only a final inspection is needed, please call the inspection request line at
(760) 602-2725.
If you have any questions, please contact the Building Inspection Department at (760) 602-2700.
Christine Wauschek
Office Specialist
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (76O) 6O2-27OO • FAX (76O) 602-856O
City of Carlsbad
May 19, 2009
CHRISTINA COURTNEY TRUST 4-7-05
1 774 COTTON WOOD AV
CARLSBAD CA 92011
RE: BUILDING PERMIT EXPIRATION
Building Department
Permit Number: CB082291
Issue Date: 12/30/2008
ADDRESS: 1774 COTTONWOOD AV
PLEASE CALL FOR AN INSPECTION IF WORK IS
COMPLETE
Our records indicate that your building permit will expire by limitation of time on 06/28/2009.
The provisions of UBC, Section 106.4.4 as amended by the Carlsbad Municipal Code state: "EXPIRATION.
Every permit issued by the Building Official under the provisions of this code shall expire by limitation and
become null and void if the building or work authorized by such permit is not commenced within 180 days from
the date of such permit, or if the building or work authorized by such permit is stopped at any time after the work
is commenced for a period of 180 days or if the building or work authorized by such permit exceeds three
calendar years from the issuance date of permit. Work shall be presumed to have commenced if the permittee has
obtained a required inspection approval of work authorized by the permit by the Building Official within 180
days of the date of permit issuance. Work shall be presumed to be stopped if the permittee has not obtained a
required inspection approval of work by the Building Official within each 180 day period upon the initial
commencement of work authorized by such permit.
Before such work can be recommenced, a new permit shall be obtained to do so, and the fee, therefore, shall be
one-half the amount required for a new permit for such work, and provided that no changes have been made or
will be made in the original plans and specifications for such work, and provided further that such suspension or
abandonment has not exceeded one year. In order to renew action on a permit after expiration, the permittee shall
pay a new permit fee.
Any person holding an unexpired permit may apply for an extension of the time within which work may
commence under that permit when the permittee is unable to commence work within the time period required by
this section for good and satisfactory reasons. The Building Official may extend the time for action by the
permittee for a period not exceeding 1 80 days on written request by the permittee showing that circumstances
beyond the control of the permittee have prevented action from being taken. No permit shall be extended more
than once.
Please check below indicating your intentions and return this letter to us.
_ Project abandoned. A new permit will be obtained prior to commencing work.., 4 . i i
t^ No fee extension requested for 180 days, (attach a letter of explanation) FVJvM«v/cj. iM. p/iptxe**i
_ Renewal permit requested.
If the project has been completed and only a final inspection is needed, please call the inspection request line at
1/60)602-^725.
If you have any questions, please contact the Building Inspection Department at (760) 602-2700.
Christine Wauschek
Office Specialist
1635 Faraday Avenue • Carlsbad, CA 92008-7314 • (760) 602-2700 • FAX (760) 602-8560
City of Carlsbad Bldg Inspection Request
For. 01/05/2009
Permit* CB082291
Title: SEAPORT HOA- REPLACE EXPOSED
Description: GAS LINE FROM P/L TO HOUSE
Inspector Assignment: JM
1774 COTTONWOOD AV
Lot: 0
Type: PLUM Sub Type:
Job Address:
Suite:
Location:
OWNER COURTNEY CHRISTINA TRUST 04-07-05
Owner: COURTNEY CHRISTINA TRUST 04-07-05
Remarks:
Phone: 7606855475
Inspector:
Total Time:
CD Description
21 Underground/Under Floor
Act Comments
A\ (
Requested By: A.C.G. PLUMBING
Entered By: CHRISTINE
Comments/Notices/Holds
Associated PCRs/CVs Original PC#
Inspection History
Date Description Act Insp Comments
12/31/2008 23 Gas/Test/Repairs CO JM MIN10LBS
ENGINEER
CORIA CORIA
SITE PLAN SCALE: l/32"=r
TAMARACK AVE
TABLE OF CONTENTS
PAGE*
PV-01
PV-02
PV-03
DESCRIPTION
SITE PLAN
STRUCTURAL DETAIL
ELECTRICAL DETAIL
AR-01
-130' CONDUIT RUN
18"UNDERGROUND
INVERTER
LOCATION
DC DISCONNECT
AC DISCONNECT
SERVICE
ENTRANCE
STORM WATER
NOTE 9
SYSTEM INFORMATION
ARRAY
AR-01
PITCH
30°
MAGNETIC
ORIENTATION
170°
TRUE
ORIENTATION
183°
EXISTING
POOL
g
ff ' \, •> ••• ;
PROPERTY
LINE
VICINITY MAP
EXISTING
RESIDENCE
NOTES:
1) 6.3 KW SOLAR SYSTEM INSTALLED BY REC SOLAR CL # 750184
2) SOLAR MODULES MOUNTED ON GROUND TO GALVANIZED PIPE SUBSTRUCTURE USIN
SOLAR RACKING ALUMINUM RACKING SYSTEM.
3) EARTH IS COMPACT SLOPED HARD DIRT.
4) INVERTER LOCATED BY MAIN PANEL.
5) CONNECT SYSTEM TO MAIN PANEL VIA PV BREAKER.
6) RUN CONDUIT THROUGH TRENCH ~130' TO MAIN PANEL.
7) THIS PROJECT WILL COMPLY WITH 2007CBC, 2007 CEC.
8) PV SYSTEM INSTALLATION SHALL COMPLY WITH THE REQUIREMENTS OF ARTICLE 69$\
CEC.
9) CONSTRUCTION STORM WATER BPM EROSION AND SEDIMENT CONTROL METHOD MULCH,
WOOD CHIPS AROUND FOOTINGS AND TRENCH. STRAW WADDLE AT BASE OF SLOPE.
REC SOLAR, INC.
CA CL# 750184 77S Flero Lane, Suite 200
San Luis Obispo, CA 93401 USA
Phone (888)657-6527 Fax (805)528-9701
CUSTOMER APPROVAL
PROJECT FOREMAN
PLANS REVIEWED:
BOM REVIEWED:
HACKETT RESIDENCE
3820 CROWNPOINT CT
CARLSBAD, CA 92010
: \l mukmentibon VPrvJerli WiTltel 1,4R-e20HACK_OS09\Engln«rin«\Working Design DocunwritiVHidM!
PV-01 REV: A
7/2/2009
n
7sm
ENGINEER
CORIA CORIA
DESCRIPTION
PHOTOVOLTAIC SYSTEM
NOTES:
SANYO HIP-210NKHA5
21OW MODULES
62.2" X 31.4" X 1.8"
STRUCTURAL DETAIL
TYPICAL GROUND MOUNT
INSTALLATION WITH
KEE KLAMP HARDWARE:
1-1/2 " SINGLE SOCKET T (172-05310)
1-1/2 " SWIVEL SOCKET (172-05410)
1-1/2 " 3-SOCKET "T (172-05330)
1-1/2 " PLASTIC PLUG (172-05510)
GROUND ARRAY
MOUNTING
DETAIL
5/16 x 2-1/2" S.S. BOLT
SILVER (162-01073)
BLACK (015-11773)
5/16 S.S. SPLIT
LOCK WASHER
SILVER (165-02200)
BLACK (165-02201)
MODULE END CLAMP
VARIOUS SIZES
(232-020**)
CHANNEL NUT
(232-02005)
DETAIL: "A" PIPE TO
RAIL CONNECTION
5/16 S.S. SPLIT
LOCK WASHER
(165-02200)
5/16 x 1"
S.S. BOLT
(162-01060)
GROUND MOUNT
RAIL (232-02170)
RAIL SPLICE INSERT
(232-01032)
1.5" GALVANIZED
STEEL PIPE (172-01060)
PROPERTY LINE
1.5" GALVANIZED
STEEL PIPE
SCALE: 1/4" = I1
MODULE LAYOUT SCALE: 3/16" = 1'PROPERTY LINE
Ol
REC SOLAR, INC.
CA CL# 750184 775 Rero Lane, Suite 200
San Luis Oblspo, CA 93401 USA
Phone (888)657-6527 Fax (805)528-9701
CUSTOMER APPROVAL
PROJECT FOREMAN
PLANS REVIEWED:
BOM REVIEWED:
HACKETT RESIDENCE
3820 CROWNPOINT CT
CARLSBAD, CA 92010
PV-02 REV: A
7/2/2009
n
rn
ENGINEER
ELECTRICAL DETAIL
120/240 VAC
SINGLE PHASE SERVICE
200 AMP BUSSING
200 AMP MAIN
3/4" EMT OR EQUIVALENT:
(2) 8 AWG THHN/THWN-2 CONDUCTORS
-(1) 8 AWG THHN/THWN-2 NEUTRAL
\(l) 8 AWG THHN/THWN-2 GROUND
1" EMT OR EQUIVALENT:
(6) 8 AWG THHN/THWN-2 CONDUCTORS
(1) 8 AWG THHN/THWN-2 GROUND
CONDUCTORS EXPOSED TO FREE AIR:
(6) 8 AWG RHW/USE-2 CONDUCTORS
(1)8 AWG BARE COPPER GROUND
40 AMP
PV
BREAKER
ELECTRICAL NOTES:
1. GROUNDING WIRE WILL BE BONDED DIRECTLY TO FACILITY GROUND
2. ELECTRICAL SYSTEM GROUNDING WILL COMPLY WITH 2005 NEC 250
3. MODULE INTERCONNECTIONS WILL BE MADE WITH 10 AWG RHW/USE-2 WIRE.
4. ARRAY CONDUCTORS ARE SIZED FOR DERATED CURRENT PER STRING
5.57 AMPS SHORT CIRCUIT CURRENT
125% DERATING FOR EXTREME IRRADIANCE CONDITIONS
(NEC 690-8 (a))
125% DERATING, CONTINUOUS PHOTOVOLTAIC SOURCE CURRENT
(NEC 690-8 (b))
156% TOTAL DERATING (COMBINATION OF ABOVE)
8.68 AMPS TOTAL CAPACITY
(AMPS TOTAL CAPACITY = STRING SHORT CIRCUIT CURRENT MULTIPLIED BY
TWO ABOVE DERATES, 1.25 X 1.25 X SHORT CIRCUIT CURRENT)
5. INVERTER PROVIDES NECESSARY GROUND FAULT PROTECTION AS REQUIRED
BY 2005 NEC 690.5 GROUND FAULT PROTECTION.
6. PHOTOVOLTAIC SYSTEM HAS CONDUCTOR BONDED TO GROUND IN INVERTER
AS REQUIRED BY 2005 NEC 690.41 SYSTEM GROUNDING, AND 690.42 POINT OF
SYSTEM GROUNDING CONNECTION.
7. ACCESS TO DC WIRING WILL BE RESTRICTED TO QUALIFIED PERSONNEL ONLY.
WHERE DC PHOTOVOLTAIC OUTPUT CIRCUITS ARE RUN INSIDE A BUILDING THEY
SHALL BE CONTAINED IN A METALLIC RACEWAY OR ENCLOSURE (MARKED
"CAUTION DC CIRCUIT" EVERY 5') FROM THE POINT OF PENETRATION TO THE
FIRST READILY ACCESSIBLE DISCONNECTING MEANS - 2005 NEC 690.31 (E).
STRAIN RELIEF CABLE CLAMPS OR CONDUIT USED ON ALL CABLES AND CORDS.
8. USE UL APPROVED BONDING FITTINGS AT ALL CONDUIT/BOX JUNCTIONS.
9. MODULES CONFORM TO AND ARE LISTED UNDER UL 1703
10. INVERTER CONFORMS TO AND IS LISTED UNDER UL 1741
SMA SB6000US(240V)
6000 WATT INVERTER AND
FUSED DISCONNECT ASSMBLYMANUAL
LOCKABLE
DISCONNECT INVERTE
AC OUT
SQUARE D
DU222RB
60A 120/240 VAC
(30) SANYO HIP-210NKHA5 MODULES
IN (3) STRINGS OF (10) MODULESJEACt
509 VDC EXPECTED OPEN GIF
STRING VOLTAGE
15 AMP FUSED, 4-STRING COMBINER
AND LOAD RATED DISCONNECT TO
ISOLATE INVERTER FOR SERVICE.
CAPABLE OF BEING CHANGED
WITHOUT TOUCHING LIVE CONTACTS.
3UNCT1ON BOX LOCATED ON
ROOF UNDER ARRAY TO
TRANSITION FROM RHW/USE-2
TO THHN/THWN-2
MODULE CHARACTERISTICS
SANYO HIP-210IMKHA5
Open Circuit Voltage
Open Circuit Voltage: (NEC 690.7)
Max Power Voltage
Short Circuit Current
Short Circuit Current: (NEC
690.8(A)(1))
210
50.9
57.5
41.3
5.5
6.8
Watts
V
V
V
Amps
Amps
SYSTEM 1&2 CHARACTERISTICS
STICKER
System Size
System Open Circuit Voltage
System Operating Voltage
Max Allowable DC Voltage
System Operating Current
System Short Circuit Current
6.3
509
575.1
600
15.2
20.8
kW
V
V
V
Amps
Amps
- WARNING -
THIS EQUIPMENT IS
POWERED BY A
PHOTOVOLTAIC POWER
SOURCE
- WARNING -
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH LINE AND LOAD
SIDE MAY BE ENERGIZED
LABEL: MAIN SERVICE PANEL,
EXISTING SUBPANELS, AND
EXISTING EQUIPMENT TIED
INTO.
LABEL: REC INSTALLED
SUBPANELS AND FUSE BOXES.
- WARNING -
DO NOT ENTER
THIS EQUIPMENT IS POWERED
BY A PHOTOVOLTAIC POWER
SOURCE
LABEL: DC DISCONNECT OR INVERTER
LABEL: REC INSTALLED,
JUNCTION BOXES, COMBINER
BOXES AND GUTTER BOXES.
PHOTOVOLTAIC
DISCONNECT
- WARNING -
ELECTRIC SHOCK HAZARD
DO NOT TOUCH TERMINALS.
TERMINALS ON BOTH LINE AND LOAD
SIDE MAY BE ENERGIZED
LABEL: AC, DC DISCONNECT OR
OTHER DISCONNECTING MEANS.
01 AR
REC SOLAR, INC.
CA CL# 7S0184 775 Rero Lane, Suite 200
San Luis Oblspo, CA 93401 USA
Phone (888)657-6527 Fax (805)528-9701
CUSTOMER APPROVAL
PROJECT FOREMAN
PLANS REVIEWED:
BOM REVIEWED:
HACKETT RESIDENCE
3820 CROWNPOINT CT
CARLSBAD, CA 92010
PV-03 REV: A
7/2/2009