HomeMy WebLinkAbout1808 ASTON AVE; 185; CB142661; Permit11-14-2014
City of Carlsbad
1635 Faraday Av Carlsbad.CA 92008
Commercial/Industrial Permit Permit No:
Building Inspection Request Line (760) 602-2725
CB142661
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
Project Title:
1808 ASTON AV CBADSt: 185
Tl Sub Type: INDUST
2121200700 Lot#: 0
$173,280.00 Construction Type: 5A
Reference #
N-TENT, 4000 SF OFFICE TO
OFFICE
Status: ISSUED
Applied: 10/14/2014
Entered By: RMA
Plan Approved: 11/14/2014
Issued: 11/14/2014
Inspect Area
Plan Check #:
Applicant:
PACIFIC BUILDING GROUP
STE 150
9752 ASPEN CREEK CT
SAN DIEGO, CA 92126
858-552-0600
Owner:
MCR ASTON LLC
1808 ASTON AVE #180
CARLSBAD CA 92008
Building Permit $887.28 Meter Size
Add'l Building Permit Fee $0.00 Add'l Red. Water Con. Fee $0.00
Plan Check $621.10 Meter Fee $0.00
Add'l Building Permit Fee $0.00 SDCWA Fee $0.00
Plan Check Discount $0.00 CFD Payoff Fee $0.00
strong Motion Fee $48.52 PFF (3105540) $0.00
Park Fee $0.00 PFF (4305540) $0.00
LFM Fee $0.00 License Tax (3104193) $0.00
Bridge Fee $0.00 License Tax (4304193) $0.00
BTD #2 Fee $0.00 Traffic Impact Fee (3105541) $0.00
BTD #3 Fee $0.00 Traffic Impact Fee (4305541) $0.00
Renewal Fee $0.00 PLUMBING TOTAL $49.00
Add'l Renewal Fee $0.00 ELECTRICAL TOTAL $74.75
Other Building Fee $0.00 MECHANICAL TOTAL $44.59
Pot. Water Con. Fee $0.00 Master Drainage Fee $0.00
Meter Size Sewer Fee $0.00
Add'l Pot. Water Con. Fee $0.00 Redev Parking Fee $0.00
Reel. Water Con. Fee $0.00 Additional Fees $0.00
Green BIdg Stands (SBI473) Fee $4.00 HMP Fee ??
Fire Expedidted Plan Review $475.00 Green BIdg Standards Plan Chk ??
TOTAL PERMIT FEES $2,204.24
Total Fees: $2,204.24 ayments To Date: $2,204.24 Balance Due: $0.00
Inspector:
FINAL APPROVAL
Date: //A^A^X Clearance:
NOTICE: Please take NOTICE fnat approval of your project includes the "Imposition" of fees, dedications, resen/ations, or other exactions hereafter collectively
referred to as "fees/exactions." You have 90 days from the date this pemit vi(as issued to protest Imposition of these fees/exactions. If you protest them, you must
follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for
processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity
changes, nor pianning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any
fees/exactions of which vou have previouslv been given a NOTICE similar to this, or as to which the statute of limitations has previousiv otherwise expired.
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: nPLANNING IZIENGINEERING • BUILDING •FIRE •HEALTH •HAZMAT/APCD
T
^ CITY OF
CARLSBAD
Building Permit Appiication
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carisbadca.gov
CT/PROJECT « L0T# PHASE* # OF UNITS tt BEDROOMS # BATHROOMS TENANT BUSINESS NAME CONSTR. TYPE occ. GROUP
69 1 N-TENT V-A B
JOB ADDRESS 1808 Aston Ave, Carlsbad, CA 92008
SUITE</SPACE*/UNIT*
DESCRIPTION OF WORK: /nclude Square Feet of Affected Areafs)
Tenant improvement to Include new partitions, electrical, mechanical (ductwork only), and plumbing. Area of improvement
is 4,000 square feet.
EXISTING USE
Office
PROPOSED USE
Office
GARAGE (SF)
0
PATIOS (SF)
0
DECKS (SF)
0
FIREPLACE
YESfn* NOfn
AIR CONDITIONING
YES [7] NO •
FIRESPRINKLERS
YESITINOI I
APPLICANTNAME (Primary Contact) Tara Norton APPLICANTNAME (Secondary Contact) Chris Brandley
ADDRESS 5090 Shoream Place, Suite 100 ADDRESS 5090 Shoream Place, Suite 100
CITY San Dieao STATE
CA
ZIP
92122
CITY San Dieqo CA 92122
PHONE
619-297-1011 yiA
FAX PHONE
619-297-1011
EMAIL tnorton@rbn-desiqn.com EMAIL
cbrandley@rbn-desiqn.com
PROPERTY OWNER NAME MCR Aston LLC CONTRACTOR BUS. NAME Pacific Buildina Group
ADDRESS
1808 Aston Ave, Suite 180
ADDRESS 9752 Aspen Creek Court
CITY
Carlsbad
STATE
CA 92008 San Dieao
STATE
CA
ZIP
92126
PHONE
760-929-5020
FAX
858-334-4103
FAX
EMAIL quy@mcrlaw.com EMAIL
ARCH/DESIGNER NAME & ADDRESS
RBN Desian 502376 B
CITY BUS. LIC.«
1207435
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to Its issuance, also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commending with Section 7000 of Division 3 of the Business and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subjects the applicant to a civil penalty of not more than five hundred dollars ($500)).
WORKERS- COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one ofthe foltowing declarations:
• I have and will maintain a certificate of consent to selMnsure for workers' compensation as provided by Section 3700 cf the Labor Code, for the performance of the work for which this pennit is issued.
i Iiave and will maintain woriters' compensation, as reauired bv Section 3700 of the Labor Code, for the perfomiance of the wori( for which this pemit is issued. My workers' compensation insurance carrier and policy
number are: Insurance Co,_ Lockton Insurance Brokers, LLC Policy No.. A1CG36841307 Expiration Date _
Thjs section need not be completed if the permit is for one hundred dollars ($100) or less.
I I Certificate of Exemption: I certify that in the performance of the work for which this pemiit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
Califomia WARNiNG: Failure to sepure woriters' compensation coverage is unlawful, and shaii subject an employer to criminal penalties and civil fines up to one hundred thousand doiiars (&100,000), in
addition to the cost of compensaticir, damages as provided for in Section 3706iof the Labor code. Interest and attomey's fees.
JS^ CONTRACTOR SIGNATURE S* / I/} ^'^3'ifV T '^'^ [TJAGENT DATE
OWNER-BUILDER OECLARATION
/ hereby alfinn that I am exempt from Contractor's Ucense Law for the following reason:
[ I I, as owner of the property or my employees witti wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements ate not intended or offered for
, sale. If, however, the building or improvement is sold within one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
1^3 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
/ property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I I I am exempt under Section Business and Professions Code for this reason:
1.1 personally plan to provide the major labor and materials for construction of the proposed property improvement. QVes I INO
2,1 (have / have not) signed an application for a building perniit for the proposed work.
3.1 have contracted with the following person (fimi) to provide the proposed constaiction (include name address / phone / contractors' license number):
4.1 plan to provide portions of the work, but I have hired the following person to coordinate, supen/ise and provide the major work (indude name / address / phone / contractors' license number):
5,1 will provide some of the work, but I have contracted (hire(Mie following persons to provide the work indicated (include name / address / phone / type of work):
AGENT DATE
COMPLETE THiS SECTION FOR N O N-R E S I D E N Tl A L BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business plan, xutely hazardous materials registration form or risk management and prevention program under Sections 25505,25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Acr? Yes / No
Is the applicant or future building oaupant required to obtain a pemiit from the air pollution control district or air quality management district? Yes / No
Is the fxility to be constructed within 1,000 feet of the outer boundary of a school site? Yes /No
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCV
I hereby affinn ttiat there is a construction lending agency for the performance of the work this pemiit is issued (Sec. 3097 (!) Civil Code).
Lender's Name Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the applteatton and state that ttie atxwe infomfiation is conectand that the infbimation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building constnictnn.
I hereby authorize nepresentative of the City of Carisbad to enter upon the above mentbned property for inspeclion purposes, I ALSO AGREE TO SAVE, INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL UABILmES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: An OSHA pemiit is required Ibr excavations over 5'0' deep and demolition or constniction of structures over 3 stories in height.
EXPIRATION: Every pennit issued by the Building Official under the provisions ofthis Code shall expire by limitation and become null and void if the buikJing or vrark authorized by such pennit is not commenced within
180 days from the date of such pemnitor if the building or viort< authorized by such pemiit is suspended or abandoned at any time after the •mk is oommenced for a period of 180 days (Section 106.4.4 Unifomi Building Code).
APPLICANT'S SIGNATURE
ort< authorized by such pemiit is suspended c
DATE
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY If a Certificate of Occupancy will be requested at fmal inspection.
Fax (760) 602-8560, Email buildinq(S>carlsbadca.qov or Mall the completed forni to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, Califomia 92008.
C0#: (Office Use Only)
CONTACT NAME OCCUPANT NAIVIE
ADDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE
Carlsbad CA
PHONE
OCCUPANT S BUS. LIC. No.
DELIVERY OPTIONS
PICK UP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
MAILTO: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
MAIL / FAX TO OTHER:
ASSOCIATED CB#-
NO CHANGE IN USE / NO CONSTRUCTION
CHANGE OF USE / NO CONSTRUCTION
>ef APPLICANT'S SIGNATURE DATE
Inspection List
Permit#: CB142661 Type: Tl INDUST N-TENT, 4000 SF OFFICE TO
OFFICE
Date Inspection Item Inspector Act Comments
12/23/2014 89 Final Combo -Rl COF
12/23/2014 89 Final Combo PY AP
12/12/2014 85 T-Bar -Rl AFTER 9:00 PLEASE
12/12/2014 85 T-Bar PB AP
11/24/2014 17 Interior Lath/Drywall PY AP
11/19/2014 14 Frame/Steel/BoltingA/Veldin PY AP
11/19/2014 21 Underground/Under Floor PY AP
11/19/2014 34 Rough Electric PY AP
Wednesday, December 24, 2014 Page 1 of 1
<^':'
c I 1 V or
iCARLSBAD INSPECTION RECORD
Building Division
(Zl INSPECTION RECOnO CARO WITH APPROVED
PLANS MUST BE KEPT ON THE JOB
i3 CALL BEFORE 3;30 pm FOR NEXT WORK DAY INSPECTION
0 FOR BUiLDING INSPECTION CALL: 760-602-2725
OR GO TO: WAyw.Carlibadca.qov/Buildinq AND CLICK ON
"Request inspection"
DATE: lijiK/f/iJ
CB142661 1808 ASTON AV 185
N-TENT, 4000 SF OFFICE TO
OFFICE
Tl INDUST
Lot#- PACIFIC BUILDING GROUP
IF "YES" FS CHECKED BELOV
IF YOU HAVE ANY QUESTIONS
DIVISION'S APPROVAL ts REQUI
E CALL THE APPLICABLE OIVI
IEO OFF- FAX TO 760-602-8
BIDING IN A COPY OF THIS CA
AT 760-602-2700 SETvifEEN '
HONE NUMBERS PROVIDEO BELOW. AFTER
BLO GIN S P ECT I OM S FS CAR LS B A DCA .GOV OF?
. BUILDING INSPECTORS CAN BE REACHED
8:O0 AM THE DAY OF YOUR INSPECTION.
1 NJU Required Prior to Requesting Building Final If Checked YES Date Inspector Notes
Planning/Landscape 760-944-8463 Allow 48 hours
CM&I (Engineering Inspections) 760-438-389T Call before 2 pm fl
y Fire Prevention 760-602-4660 Allow 48 hourj
i I
Type of Inspection
FOUNDATSOS
coDE« BUILDING
#11
Date
#12
#66
REINFORCtD STill
MASONRY PRE GROUT
• GROUT • WAU DRAINS
Inspector
Type of Inspection
CODE n ELECTRICAL
n\ O EIECTRIC UNDERGROUND O IFER
Oate
<>34 ROUGH EIECTRIC
#33 • EUCIRIC SERVICE • TEMPORARV
«3S PHOTOVOLTAIC
•A f f i lv-'--
inspector
#10 TILT PANELS
#11 POURSTRIPS
#11 COLUMN rOOIINCS
«39 FINAL
CODE a MECHANICAL
(^41 UNDERGROUND OUCTS & PIPING
#14 SUBFRAME 0 FIOOR • CEILING • OUCT & PLENUM DREF. PIPING
#15 ROOFSHEATHING #43 HEAT AIR COND SYSTEMS
#13 EXT, SHEAR PANELS
#16 INSULATION
#18 EXTERIOR UIM
#17 INTERIOR LATH t, ORVWAI.I.
#51 POOLEXCA/SUEL/BONO/FEtlCt
'——
S49 FINAL
Coot tt COM BO I NSPECTION
#81 UNDERGROUNDill,12.21,311
n%2 DRYWALl^EX! LATH, CASTESjJMS.:31
1)83 ROOF SHEATING, EXTSHEAR (13.]5»
#55 PREPUSTEft/FfNAl lg4 FRAME ROUGH COMBO 114.24.34.44}
#19 FINAL
COOEV PLUIVIBING
• SEWER & BL/CO
fSS T-BaitH.24,31,4«|
Date Inspector #89 FINAL OCCUPANCV (19,29,39,49)
SEE BACK FOR SPECIAL NOTES
EsGil Corporation
In PartnersHip witH government for (BuiCifing Safety
DATE: 11/12/2014 • APPLICANT
• JURIS.
JURISDICTION; Carlsbad • PLANREVIEWER
• FILE
PLANCHECKNO.: CB14-2661 SET: II
PROJECTADDRESS: 1808 Aston Suite 185
PROJECT NAME: NTENT TI
Xl The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
I I The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
I I The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant
contact person.
I I The applicant's copy of the check list has been sent to:
EsGil Corporation staff did not advise the applicant that the plan check has been completed.
I I EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone*:
Date contacted: (by: ) Email
Mail Telephone Fax In Person
n REMARKS:
By: John Le Vey Enclosures:
EsGil Corporation
• GA • EJ • MB • PC 11/05/2014
9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576
EsGil Corporation
In PartnersHip witH government for (BuiCcfing Safety
DATE: 10/24/2014 •^PPLICANT
JURIS.
JURISDICTION: Carlsbad • PLANREVIEWER
• FILE
PLANCHECKNO.: CB14-2661 SET: I
PROJECTADDRESS: 1808 Aston Suite 185
PROJECT NAME: NTENT TI
I I The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
I I The plans transmitted herewith will substantially comply with the jurisdiction's
codes when minor deficiencies identified below are resolved and checked by building
department staff.
I I The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
I I The applicant's copy of the check list is enclosed for the jurisdiction to fonward to the applicant
contact person.
I I The applicant's copy of the check list has been sent to:
I I EsGil Corporation staff did not advise the applicant that the plan check has been completed.
EsGil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Tara Norton Telephone #: 619-297-1011
Date contacted: (by. AA ) Email: tnorton(grbn-design.com Fax #:
Mail ^J«lephone Fax In Person
• REMARKS^
By: John Le Vey Enclosures:
EsGil Corporation
• GA • EJ • MB • PC 10/16/2014
9320 Chesapeake Drive, Suite 208 • San Diego, Califomia 92123 • (858) 560-1468 • Fax (858) 560-1576
Carlsbad CB 14-2661
10/24/2014
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLANCHECKNO.: CB14-2661 JURISDICTION: Carlsbad
OCCUPANCY: B USE: Office
TYPE OF CONSTRUCTION: VA ACTUAL AREA: 4034
ALLOWABLE FLOOR AREA: STORIES: 2
HEIGHT: unknown
SPRINKLERS?: Yes OCCUPANT LOAD: 40
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION: 10/14/2014
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 10/16/2014
DATE INITIAL PLAN REVIEW
COMPLETED: 10/24/2014
PLAN REVIEWER: John Le Vey
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2013 CBC, which adopts the 2012 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2012 International Building Code, the approval ofthe plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet number, specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
Carlsbad CBI4-2661
10/24/2014
Please make all corrections, as requested in the correction list. Submit FOUR new
complete sets of plans for commercial/industrial projects (THREE sets of plans for
residential projects). For expeditious processing, corrected sets can be submitted
in one of two ways:
1. Deliver all corrected sets of plans and calculations/reports directly to the City of
Carlsbad Building Department, 1635 Faraday Ave., Carlsbad, CA 92008, (760)
602-2700. The City will route the plans to EsGil Corporation and the Carlsbad
Planning, Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468.
Deliver all remaining sets of plans and calculations/reports directly to the City of
Carlsbad Building Department for routing to their Planning, Engineering and Fire
Departments.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
reviewed bythe City Planning, Engineering and Fire Departments until review by
EsGil Corporation is complete.
1. Please correct the suite # on sheet Tl-3 it states suite 170 correct to match
2. Please explain the removal of the header beam in the open office to be removed
as stated on sheet TI-4, clarify on the plans what this entails, is it bearing,
supporting etc.
3. Please clarify why there is not a return air in office 105
4. Please show the exit signs on the power plan sheet E-1.0
5. Please provide a plumbing plan for the new break room sink.
6. Please show the location of the transformer on the electrical power plan , provide
the support ofthe transformer if required and compliance with 450.13.B , also
show compliance with 240.21 (3) tap rule
Advisory Note : When alterations, structural repairs or additions are made to an
existing building, that building, or portion ofthe building affected, is required to
comply with all of the following requirements, per Section 11 B-202.4:
• The area of specific alteration, repair or addition must comply as "new"
construction.
• A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
• The path of travel shall include the existing parking.
• Existing toilet and bathing facilities that serve the remodeled area must be
shown to comply with all accessibility features.
• Please address the following comments that are the result of the alterations.
7. Show on the site plan the complying disabled accessible path of travel from the
disabled accessible parking spaces to the primary entrance of the tenant space.
Please provide detailed plans ofthe path of travel, indicate slope and width, any
Carlsbad CBI4-2661
10/24/2014
pedestrian ramps, curb ramps, walks, handrails, provide dimensioned parkinq
stall details etc.
8. It is unclear from the plans if the restrooms servicing the tenant improvement are
disabled accessible, please provide a dimensioned restroom plans showing the
restroom to be accessible compliant.
To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please brieflv
describe them and where they are located in the plans.
Have changes been made to the pfans not resulting from this correction
list? Please indicate: • Yes • No
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. Ifyou have any
questions regarding these plan review items, please contact John Le Vey at
Esgil Corporation. Thank you.
Carlsbad CBI4-2661
10/24/2014
[DO NOT PAY- THIS IS NOTAN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad PLANCHECKNO.: CB14-2661
PREPARED BY: John Le Vey DATE: 10/24/2014
BUILDING ADDRESS: 1808 Aston Suite 185
BUILDING OCCUPANCY: B
BUILDING
PORTION
AREA
(Sq. Ft.)
Valuation
Multiplier
Reg.
Mod.
VALUE ($)
Tl Per City 173,280
Air Conditioning
Fire Sprinklers
TOTAL VALUE 173,280
Jurisdiction Code cb By Ordinance
BIdg. Permit Fee by Ordinance
Plan Check Fee by Ordinance
Type of Review: 0
r~l Repetitive Fee
1 Repeats
Complete Review
• Other
|—j Hourly
EsGil Fee
• Structural Only
Hr. @ *
$888.76
$577.69
$497.71
Comnnents: Sheet of
PLAN CHECK PLAN CHECK Community & Economic
^ CITY OF REVIEW Development Department
1635 Faraday Avenue
CARLSBAD TRANSMITTAL Carlsbad CA 92008
www.carisbadca.gov
DATE: 10/24/14 PROJECTNAME: N-TENT-Tenant Improvement PROJECTID:
PLAN CHECK NO: CB142661 SET#:1 ADDRESS: l^OS Aston Ave, Unit 185 APN: 212-120-07
VALUATION: $173,280 APPLICANT CONTACT: Tara Norton/tnorton@rbn-clesign.com
X Ths plan check review transmittal is to notify you of clearance by:
LAND DEVELOPMENT ENGINEERING DIVISION
Final Inspection by the Construction & Inspection Division is required: Yes No X
'/X^ For status from a division not marked below, please call 760-602- 2719
This plan check review is NQTCOMPLETBItems missing or incorrect are listed
on the attached checklist. Please resubmit amended plans as required.
LAND DEVELOPMENT ENG.
760-602-2750
linda Ontiveros
760 -602-2773
Linda.Ontiveros@carlsbadca.gov
V/ Dale Willis
X\ 760-602-2784
Dale.Wiiils@carisbadca.gov
Remarks: No additional Engrg Fees
CITY OF
CARLSBAD
STORM WATER
COMPLIANCE
ASSESSMENT
B-24
Development Services
Building Division
1635 Faraday Avenue
760-602-2719
www.carisbadca.gov
am applying to the City of Carlsbad for the following type(s) of construction permit:
Building Permit • Right-of-Way Permit
^^My project is categorically EXEMPT from
the requirement to prepare a storm water
pollution prevention plan (SWPPP) because it
only requires issuance of one or more of the
following permit types:
Electrical
Fire Additional
Fire Alarm
Fixed Systems
Meclianical
Mobile Home
Plumbing
Patio/Deck
Photo Voltaic
Re-Roofing
Sign
Spa-Factory
Sprinkler
Water Discharge
Project Storm Water Threat Assessment Criteria*
No Threat Assessment Criteria
My project qualifies as NO THREAT and is exempt from the requirement to prepare a stonn water pollution prevention plan (SWPPP) because
it meets the "no threat" assessment criteria on the City's Project Threat Assessment Worksheet for Determination of Constaiction SWPPP Tier
Level. My project does not meet any of the High, Moderate or Low Threat criteria described below.
Tierl • Low Threat Assessment Criteria
• My project does not meet any of the Significant or Moderate Threat criteria, is not an exempt pemnit type (See list above) and the project
meets one or more ofthe following criteria:
• Results in some soil disturbance; and/or
• Includes outdoor constmction activities (such as saw cutting, equipment washing, material stockpiling, vehicle fueling, waste stockpiling).
r/er2 - Moderate Threat Assessment Criteria
• My project does not meet any of the Significant Threat assessment Criteria described below and meets one or more of the following criteria:
• Project requires a grading plan pursuanttothe Carisbad Grading Ordinance (Chapter 15.16 ofthe Carisbad Municipal Code); or,
• Project will result in 2,500 square feet or more of soils disturbance including any associated construction staging, stockpiling, pavement
removal, equipment storage, refueling and maintenance areas and project meets one or more of the additional following criteria:
• Located within 200 feet of an environmentally sensitive area or the Pacific Ocean, and/or
• Disturbed area is located on a slope with a grade at or exceeding 5 horizontal to 1 vertical, and/or
• Disturbed area is located along or within 30 feet of a storm drain inlet, an open drainage channel or watercourse, and/or
• Construction will be initiated during the rainy season or will extend into the rainy season (Oct. 1 through April 30).
Tier 3 • Significant Threat Assessment Criteria
• My project includes clearing, grading or other disturbances to the ground resulting in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, stockpiling, pavement removal, refueling and maintenance areas: and/or
• My project is part of a phased development plan that will cumulatively result in soil disturbance totaling one or more acres including any
associated construction staging, equipment storage, refueling and maintenance areas: or,
• My project is located inside or within 200 feet of an environmentally sensitive area (see City ESA Proximity map) and has a significant
potential for contributing pollutants to nearby receiving waters by way of storm water runoff or non-storm water discharge(s).
/ certify to the best of my knowiedge that the above
checked statements are true and correcL I understand
and acknowledge that even though this project does
not require preparation ofa construction SWPP, I must
still adhere to, and at all times during construction
activities for the permit type(s) check above comply
with ttie storm water best management practices
pursuant to Title 15 of the Carlsbad Municipal Code
and to City Standards.
'The City Engineer may authorize minor variances from the Stonm
Water Threat Assessment Criteria in special circumstances where it
can be shown that a lesser or higher Construction SWPPP Tier Level is
warranted.
Project Address: Assessor Parcel No.
1808 Aston Ave 212-120-07-00
Owner/Owner's Authorized Agent Name:
Tara Norton
Title:
Designer
Date:
City doncurr«nce By: Date:
• YES QNO
Project ID:
B-24 Page 1 of 1 Rev.03/09
C I ! Y C) F
CARLSBAD
PLANNING DIVISION
BUILDING PLAN CHECK
REVIEW CHECKLIST
P-28
Development Services
Planning Division
1635 Faraday Avenue
(760) 602-4610
www.carlsbadca.eov
DATE: 10-15-14 PROJECT NAIVIE: PROJECTID:
PLAN CHECK NO: CB 14-2661 SET#: 1 ADDRESS: 1808 Aston Av APN: 212-120-07-00
This plan check review is complete and has been APPROVED by the Planning
Division.
By: Chris Sexton
A Final Inspection by the Planning Division is required • Yes ^ No
Vou may also have corrections from one or more of the divisions listed below. Approval
from these divisions may be required prior to the issuance ofa building permit.
Resubmitted plans should include corrections from all divisions.
• This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: tnorton@rbn-design.com
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
ENGINEERING
760-602-2750
FIRE PREVENTION
760-602-4665
X Chris Sexton
760-602-4624
Chrls.Sexton@carlsbadca.gov
1 1 Kathleen Lawrence
760-602-2741
Kathleen.Lawrence@carlsbadca.gov
Q Greg Ryan
760-602-4663
Gregorv.Rvan@carlsbadca.gov
Gina Ruiz
760-602-4675
Gma.Ruiz@carlsbadca.gov
1 1 Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
Q Cindy Wong
760-602-4662
Cvnthia.Wong@carlsbadca.gov
• Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
Remarks:
REVIEW #:
Plan Checl< No. CB 14-2661 Address 1808 Aston Av#185 Date 10-15-14 Review #1
Planner Chris Sexton Phone (760) 602-4624
APN: 212-120-07-00
Type of Project & Use: Net Project Density: DU/AC
Zoning: C-M/OS General Plan: PM/OS Facilities Management Zone: 5
CFD (in/out) #_Date of participation: Remaining net dev acres:
(For non-residential development: Type of land use created by this permit: )
2 3 Legend: ^ Item Complete • Item Incomplete - Needs your action
• • Environmental Review Required: YES • NO • TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
• • Discretionary Action Required: YES • NO • TYPE
APPROVAL/RESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
D n Coastal Zone Assessment/Compliance
Project site located in Coastal Zone? YES Q NO •
CA Coastal Commission Authority? YES • NO •
If California Coastal Commission Authority: Contact them at - 7575 Metropolitan Drive,
Suite 103, San Diego, CA 92108-4402; (619) 767-2370
Determine status (Coastal Permit Required or Exempt):
• • Habitat Management Plan
Data Entry Completed? YES • NO •
If property has Habitat Type identified in Table 11 of HMP, complete HMP Permit application
and assess fees in Permits Plus
(A/P/Ds, Activity Maintenance, enter CB#, toolbar. Screens, HMP Fees, Enter Acres of
Habitat Type impacted/taken, UPDATE!)
• • Inclusionary Housing Fee required: YES • NO Q
(Effective date of Inclusionary Housing Ordinance - May 21, 1993.)
Data Entry Completed? YES • NO •
(A/P/Ds, Activity Maintenance, enter CB#, toolbar, Screens, Housing Fees, Construct
Housing Y/N, Enter Fee, UPDATE!)
• • Housing Tracking Form (form P-20) completed: YES • NO • N/A •
p-28 Page 2 of 3 07/11
Site Plan:
Kl • • Provide a fully dimensional site plan drawn to scale. Show: North arrow, property lines,
easements, existing and proposed structures, streets, existing street improvements, right-of-
way width, dimensional setbacks and existing topographical lines (including all side and rear
yard slopes). Provide legal description of property and assessor's parcel number.
City Council Policy 44 - Neighborhood Architectural Design Guidelines
• • 1. Applicability: YES • NO •
• • 2. Project complies: YES • NOn
• •
• •
Zoning:
1. Setbacks:
Front:
Interior Side:
Street Side:
Rear:
Top of slope:
Required
Required
Required.
Required
Required
2. Accessory structure setbacks:
Front: Required
Interior Side: Required
Street Side: Required
Rear; Required
Structure separation: Required
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
Shown
• •
• •
• •
• •
3. Lot Coverage:
4. Height:
Required
Required
Parking:
parkinq
Spaces Required
Shown
Shown
Shown office to office no chanqe in
(breakdown by uses for commercial and industrial projects required)
Residential Guest Spaces Required Shown
Additional Comments new ductwork onlv, no chanqe in parkinq
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUTER Chris Sexton DATE 10-15-14
p-28 Page 3 of 3 07/11
^ CITY OF
CARLSBAD
PLAN CHECK
REVIEW
TRANSMITTAL
BUILOir^G DEF't
Corr^S?^^'Economic
Development Department
1635 FaradayAvenue
Carlsbad CA 92008
www.carisbadca.gov
DATE: 11/12/2014 PROJECT NAIVIE: N-TENT PROJECT ID: CB142661
PLAN CHECK NO: 2 SET#: 1 ADDRESS: 1808 ASTON AV APN:
•
This plan check review Is complete and has been APPROVED by the FIRE Division.
By: GR
A Final Inspection by the FIRE Division is required ^ Yes • No
This plan check review is NOT COMPLETE. Items missing or incorrect are listed on
the attached checklist. Please resubmit amended plans as required.
Plan Check Comments have been sent to: T. Norton / RBN
You may also have corrections from one or more ofthe divisions listed below. Approval
from these divisions may be required prior to the issuance ofa building permit
Resubmitted plans should include corrections from all divisions.
For questions or clarifications on the attached checklist please contact the following reviewer as marked:
PLANNING
760-602-4610
ENGINEERING
760-602-2750
FIRE PREVENTION
760-602-4665
1 1 Chris Sexton
760-602-4624
Chris.Sexton@carlsbadca.^ov
1 Kathleen Lawrence
760-602-2741
Kath leen. Lawrence@carlsbadca.gov
X Greg Ryan
760-602-4663
Gregorv.Rvan@carlsbadca.gov
1 1 Gina Ruiz
760-602-4675
Gina.Ruiz@oarlsbadca.gov
1 1 Linda Ontiveros
760-602-2773
Linda.Ontiveros@carlsbadca.gov
Q Cindy Wong
760-602-4662
Cvnthia.Wong@carlsbadca.gov
• 1 1 Dominic Fieri
760-602-4664
Dominic.Fieri@carlsbadca.gov
Carlsbad Fire Department BUILDING DEP
Plan Review Requirements Category: Tl, INDUST
Date of Report: 11-12-2014 Reviewed by: ^ /^g/f
Name: PACIFIC BUILDING GROUP
Address: 9752 ASPEN CREEK CT
STE 150
SAN DIEGO, CA 92126
Permit #: CB142661
JobName: N-TENT, 4000 SF OFFICE TO
Job Address: 1808 ASTON AV CBAD St: 185
Please review carefully all comments attached.
Conditions:
CITY OF CARLSBAD FIRE DEPARTMENT - APPROVED:
THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUANCE OF BUILDING PERMIT.
THIS APPROVAL IS SUBJECT TO FIELD INSPECTION AND REQUIRED TEST, NOTATIONS HEREON, CONDITIONS IN
CORRESPONDENCE AND CONFORMANCE WITH ALL APPLICABLE REGULATIONS.
THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE THE VIOLATION OF ANY LAW.
At or prior to Final Fire and Buildinp inspection an Emergency lighting facilities test shall be conducted bv CFD
personnel during pre-dawn or dusk hours when ambient light is at 0.00 Lux or 0.0 Foot-candle.
This test shall be conducted to test the initial loss of power reading of illumination that is at least an average of 1
foot condle (11 lux) gnd a minimum of 0.1 foot-candle (1 lux) measured along the pgth of egress at the floor level.
And tested after 60-minutes to 0.6 fc (6 lux). Failure to provide sufficient lighting in egress gisles. corridors, exit
enclosures, exit possggewgys gnd stair enclosures is the AOR's responsibilitv. CFC Ch. 10. Sec. 1006.
Entry: 11/12/2014 By:GR Action: AP
" RECOMMENDED APPROVAL W/CONDITIONS
REFER TO THE TO/0 (2) CONDITIONS BELg^jj^ ^^p^, ^^^^^^
Daryl K. James & Associates, Inc Checked By: Robert Salgado
Back Check Date: 11/08/2014
APPLICANT: Tara Norton, Primary Applicant JURISDICTION: Carlsbad Fire Department
PROJECT NAME: N-TENT T.l. PROJECT ADDRESS: 1808 Aston Ave Suite #185, Carlsbad
PROJECT DESCRIPTION: CB142661 - N-TENT project consists of T.l. work in the following: B
occi'Dancy, Type V-A construction, 2-Story building, with an overall floor area of approximately 82,000
5iQ/FT. The T.l. work includes the construction of new partitions; installation of new doors and windows;
y 'finishes and millwork; and the installation of new mechanical, electrical, and plumbing systems (MEP). Fire
alarm and detection systems, fire sprinkler systems or other types of fire protection systems will be
submitted separately as deferred submittal items.
This plan review has been conducted in order to verify conformance to minimum requirements of codes
adopted by the Carlsbad Fire Department applicable to the scope of work.
The items below require correction, clarification or additional information before this plan check can be
approved for permit issuance.
^FLS COMMENTS (non-structural plan review):
• Please provide a copy of Building Department (EsGil) comments with the revised drawings
at time of 1*' BACK CHECK and input fire revisions onto the Building Department plan
check.
^SHEET A-TS. TITLE SHEET:
(1) ^Revise the "Scope of Work" statement to indicate the exact location of the T.l. work (specify the
suite number and floor/level covered within the scope of Building Permit Application.).
(2) ^Please update the "Project Data" box to show the total square footage of the entire building, and
clarify fire sprinkler substitution for 1-Hour construction or area increase.
(3) The "FIRE PROTECTION NOTES" reference the city of San Diego as the authority having
jurisdiction (AHJ); please delete San Diego and replace with Carlsbad.
(4) ^Does the (E) 82,000 SQ/FT building have a complete fire alarm and detection system? • YES or •
NO
NOTE: This would be in addition to the automatic fire safety functions for elevators and sprinkler
monitoring.
(5) ^If the answer to the question in comment #2 above is yes; then please clarify the following:
Will the T.l. work under the scope of the building application permit [CB142661] trigger fire alarm
work, such as; relocation of existing appliances or devices, or the installation of new fire alarm
appliances/devices? • YES or • NO
CONDITON #1 - Fire Inspector to field verify (E) alarm appliances and possible relocation of any
devices or alarm equipment that may have been moved as a result of the T.l. work.
(6) ^Please list all NFPA and other Consensus Standards applicable to this project and specify on plan
the current editions (Refer to 2013 CFC Chapter 80, Referenced Standards.
1
Example: NFPA STANDARDS: '
• NFPA 13, Standard forthe Installation of Sprinkler Systems as amended, 2013 Editior.
• NFPA 72, National Fire Alarm and Signaling Code as amended, 2013 Edition.
(7) ^Add a separate box onto the Title Sheet; label it: "FIRE DEPARTMENT DEFERRED SUBMITTALS"
and insert the following "TEXT" [verbatim].
^Deferred Submittal Items:
• Fully-Automatic Fire Sprinkler System, designed in accordance with 2013 CFC, Sectiori
903, and NFPA 13, 2013 edition. NOTE: The AOR should consult with the city of Carlsbad
Fire Marshal to obtain specific design criteria for aboveground fire sprinkler requirements
(hazard class/density), and underground piping (hydraulics for water supply and sprinkler \
demand).
• Fire Alarm and Detection System, 2013 CFC, Sections 907.1 through 907.9 (which
includes all other uses and occupancy groups associated with this project), and NFPA 72,
2013 edition. Specify type of system: Manual or automatic, combination automatic/manual
alarm and detection system, and specify sprinkler monitoring requirements in accordance
with 2013 CFC, 903.4 through 903.4.2.
(8) The Sheet Index letter/numbering scheme [Mechanical] does not correspond with the Mechanical
Drawings.
(9) ^Both, the description of work statement on the Building Application Permit and the scope of work
statement on Sheet Tl-1 lists "Plumbing as part of the improvements;" however, the plumbing drawings
are not listed on the Sheet Index and they are not included with the check set.
^SHEET Tl-5. PARTITION PLAN:
(1) ^Which ofthe following "CARD READER" provisions apply?
• Access-Controlled Egress Doors. 2013 CBC, Section 1008.1.9.8
• Delayed Egress Locks. 2013 CBC, Section 1008.1.9.7
NOTE: Refer to 2013 CBC, Section 1014.2, item #2; then add a note onto the plans explaining how the
locking mechanism on the door will release during a power failure or fire emergency.
(3) ^Show the fire extinguisher symbol on plan; one in the break room and the other near the main
entry/exit door.
V^SHEET Tl-6. POWER/DATA PLAN:
(1) ^Which ofthe following "CARD READER" provisions apply?
• Access-Controlled Egress Doors. 2013 CBC, Section 1008.1.9.8
• Delayed Egress Locks. 2013 CBC, Section 1008.1.9.7
^SHEET TI-8. FINISH PLAN:
(1) ^Provide specifications and California State Fire Marshal listings and other acceptance criteria for
fiame
spread and smoke developed index for new carpet, padding and carpet base, 2013 CFC, Section 804.
(2) iProvide specifications and California State Fire Marshal listings and other acceptance criteria for
flame spread and smoke developed index for wall finish material and corner guards, 2013 CBC, Section
803.1.2.
(3) ^Provide specifications and other acceptance criteria for flame spread and smoke developed index for
furniture.
(4) ^Denote all decorative materials and trim, and evidence of compliance in accordance with 2013 CFC
807.2.
(5) ^Denote all furnishings and evidence of compliance with 2013 CFC, Section 808.
^SHEET M1.2. MECHANICAL FLOOR PLAN:
(1) ^Clarify the supervisory (monitoring) requirements for the new 120 volt duct smoke detectors (DSD).
Refer to 2013 CFC, Section 907.3.1, p. 170. The DSD's must be interconnected with the building fire alarm
and detection system?
CONDITON #2 - Fire Inspector to field verify the power and supervisory requirements for the duct smoke
detectors that are connected to the HVAC system.
^SHEET E-1.0. ELECTRICAL COVER SHEET:
(1) ^Which of the following "CARD READER" provisions apply?
• Access-Controlled Egress Doors. 2013 CBC, Section 1008.1.9.8
• Delayed Egress Locks. 2013 CBC, Section 1008.1.9.7
NOTE: Refer to 2013 CBC, Section 1014.2, item #2; then add a note onto the plans explaining how the
locking mechanism on the door will release during a power failure or fire emergency, and include a wiring
schematic that depicts the fire and life safety interconnection requirements.
^SHEET E-2.0. LIGHTING PLAN:
(1) ^Add the following notes on Sheet E-2.0:
• Means of egress illumination level shall be not less than 1-foot candle at the walking surface
and equipped with not less than 90-minute battery backup, 2013 CBC, Section 1006.
• Exit signs shall be illuminated at all times and equipped with not less than 90-minute battery
backup. 2013 CBC, Section 1011.6.3.
NOTE: Provide a lighting matrix, and show the required locations of the fixtures that are equipped with
90-minute battery backup.
(2) ^Provide two separate exit signs, one directly above the main entry/exit door, and one with directional
arrows mounted at the opening of the hallway #103, which leads to the main entry/exit door.
^PLUMBING DRAWINGS: Missing?
END OF COMMENTS
CORRECTION LIST
Page: 1 of 4
BLDG. DEPT COPY
Daryl K. James & Associates, Inc. Checked By: Robert Salgado
Plan Check Date: 10/23/2014
APPLICANT: Tara Norton, Primary Applicant
RBN Design (619) 297-1011; tnorton@rbn-design.com
JURISDICTION: Carlsbad Fire Department, Fire Prevention
PROJECT NAME: N-TENT T.l. PROJECT ADDRESS: 1808 Aston Ave Suite #185, Carlsbad
PROJECT DESCRIPTION: CB142661 - N-TENT project consists of T.l. work in the following: B
occupancy. Type V-A construction, 2-Story building, with an overall floor area of approximately 82,000
SQ/FT. The T.l. work includes the construction of new partitions; installation of new doors and windows;
finishes and millwork; and the installation of new mechanical, electrical, and plumbing systems (MEP). Fire
alarm and detection systems, fire sprinkler systems or other types of fire protection systems will be
submitted separately as deferred submittal items.
This plan review has been conducted in order to verify conformance to minimum requirements of codes
adopted by the Carlsbad Fire Department applicable to the scope of work.
The items below require correction, clarification or additional information before this plan check can be
approved for permit issuance.
RESUBMITTAL INSTRUCTIONS TO AVOID DELAY IN EXPEDITED RECHECK
SERVICES:
• Corrections or modifications to the plans must be clouded and provided with
numbered deltas and revision dates.
• Provide a written response following each comment, On This Correction List,
explaining how and where you've addressed each plan review comment.
• Provide a copy of Building Department (EsGil) comments. Input flre revisions onto
the Building Department plan check.
• Please direct any questions regarding this review directly to: Robert Salgado at: (951)
541-4380, or to his email address at: flsreviewJnspection(groadrunner.com
COMMENTS MUST BE SUBMITTED DIRECTLY TO THE FOLLOWING ADDRESS TO AVOID
DELAY:
Attn: Robert Salgado
27425 Blackstone Road
Temecula, CA 92591
FLS COMMENTS (non-structural plan review):
• Please provide a copy of Building Department (EsGil) comments with the revised drawings
at time of 1^' BACK CHECK and input fire revisions onto the Building Department plan
check.
1
SHEET A-TS. TITLE SHEET:
(1) Revise the "Scope of Work" statement to indicate the exact location of the T.l. work (specify the
suite number and floor/level covered within the scope of Building Permit Application.).
(2) Please update the "Project Data" box to show the total square footage of the entire building, and
clarify fire sprinkler substitution for 1-Hour construction or area increase.
(3) The "FIRE PROTECTION NOTES" reference the city of San Diego as the authority having
jurisdiction (AHJ); please delete San Diego and replace with Carlsbad.
(4) Does the (E) 82,000 SQ/FT building have a complete fire alarm and detection system? • YES or • NO
NOTE: This would be in addition to the automatic fire safety functions for elevators and sprinkler
monitoring.
(5) If the answer to the question in comment #2 above is yes; then please clarify the following:
Will the T.l. work underthe scope of the building application permit [CB142661] trigger fire alarm
work, such as; relocation of existing appliances or devices, or the installation of new fire alarm
appliances/devices? • YES or • NO
(6) Please list all NFPA and other Consensus Standards applicable to this project and specify on plan the
current editions (Refer to 2013 CFC Chapter 80, Referenced Standards.
Example: NFPA STANDARDS:
• NFPA 13, Standard for the Installation of Sprinkler Systems as amended, 2013 Edition.
• NFPA 72, National Fire Alarm and Signaling Code as amended, 2013 Edition.
(7) Add a separate box onto the Title Sheet; label it: "FIRE DEPARTMENT DEFERRED SUBMITTALS"
and insert the following "TEXT" [verbatim].
Deferred Submittal Items:
• Fully-Automatic Fire Sprinkler System, designed in accordance with 2013 CFC, Section
903, and NFPA 13, 2013 edition. NOTE: The AOR should consult with the city of Carlsbad
Fire Marshal to obtain specific design criteria for aboveground fire sprinkler requirements
(hazard class/density), and underground piping (hydraulics for water supply and sprinkler
demand).
• Fire Alarm and Detection System, 2013 CFC, Sections 907.1 through 907.9 (which
includes all other uses and occupancy groups associated with this project), and NFPA 72,
2013 edition. Specify type of system: Manual or automatic, combination automatic/manual
alarm and detection system, and specify sprinkler monitoring requirements in accordance
with 2013 CFC, 903.4 through 903.4.2.
(8) The letter/numbering scheme on the Sheet Index does correspond with the Mechanical Drawings.
(9) Both, the description of work statement on the Building Application Permit and the scope of work
statement on Sheet Tl-1 lists "Plumbing as part of the improvements;" however, the plumbing drawings
are not listed on the Sheet Index and they are not included with the check set.
SHEET Tl-5. PARTITION PLAN:
(1) Which ofthe following "CARD READER" provisions apply?
• Access-Controlled Egress Doors. 2013 CBC, Section 1008.1.9.8
• Delayed Egress Locks. 2013 CBC, Section 1008.1.9.7
NOTE: Refer to 2013 CBC, Section 1014.2, item #2; then add a note onto the plans explaining how the
locking mechanism on the door will release during a power failure or fire emergency.
(3) Show the fire extinguisher symbol on plan; one in the break room and the other near the main entry/exit
door.
SHEET Tl-6. POWER/DATA PLAN:
(1) Which ofthe following "CARD READER" provisions apply?
• Access-Controlled Egress Doors. 2013 CBC, Section 1008.1.9.8
• Delayed Egress Locks. 2013 CBC, Section 1008.1.9.7
SHEET TI-8. FINISH PLAN:
(1) Provide specifications and Caiifornia State Fire Marshal listings and other acceptance criteria for flame
spread and smoke developed index for new carpet, padding and carpet base, 2013 CFC, Section 804.
(2) Provide specifications and California State Fire Marshal listings and other acceptance criteria for flame
spread and smoke developed index for wall finish material and corner guards, 2013 CBC, Section
803.1.2.
(3) Provide specifications and other acceptance criteria for flame spread and smoke developed index for
furniture.
(4) Denote all decorative materials and trim, and evidence of compliance in accordance with 2013 CFC
807.2.
(5) Denote all furnishings and evidence of compliance with 2013 CFC, Section 808.
SHEET Ml.2. MECHANICAL FLOOR PLAN:
(1) Clarify the supervisory (monitoring) requirements for the new 120 volt duct smoke detectors (DSD).
Refer to 2013 CFC, Section 907.3.1, p. 170. The DSD's must be interconnected with the building fire alarm
and detection system?
SHEET E-1.0. ELECTRICAL COVER SHEET:
(1) Which ofthe following "CARD READER" provisions apply?
• Access-Controlled Egress Doors. 2013 CBC, Section 1008.1.9.8
• Delayed Egress Locks. 2013 CBC, Section 1008.1.9.7
NOTE: Refer to 2013 CBC, Section 1014.2, item #2; then add a note onto the plans explaining how the
locking mechanism on the door will release during a power failure or fire emergency, and include a wiring
schematic that depicts the fire and life safety interconnection requirements.
SHEET E-2.0. LIGHTING PLAN:
(1) Add the following notes on Sheet E-2.0:
• Means of egress illumination level shall be not less than 1-foot candle at the walking surface
and equipped with not less than 90-minute battery backup, 2013 CBC, Section 1006.
• Exit signs shall be illuminated at all times and equipped with not less than 90-minute battery
backup. 2013 CBC, Section 1011.6.3.
NOTE: Provide a lighting matrix, and show the required locations of the fixtures that are equipped with
90-minute battery backup.
(2) Provide two separate exit signs, one directly above the main entry/exit door, and one with directional
arrows mounted at the opening of the hallway #103, which leads to the main entry/exit door.
PLUMBING DRAWINGS: Missing?
END OF COMMENTS
^ PLUMBING, Develooment Services
<^ »fc> ELECTRICAL, Buildtng Department
^ CITY OF MECHANICAL 1635FaradayAvenue
CARLSBAD ^^'R!??^^^ WWW cansbadca eov B-18
CIS 14I
Prc*!ctAddre$$s/8'cJ^ A-iX/4/t,S<^'U 18PermitNo.:
Information providad btkew rttan to wort) ktelng don« on the abou« mantlorwd parmK on^
This forni mutt iw complefd and returwdl to thd IwildtM Deenrtiiwiit bwfort flu ptinilt am iiimd.
Bufldng Deirt. Faic (760) 602-8SS8
f Number of neu» or relocated fhtturei, trapi, or floor drains ..^..M,......,.......-.,
New building tewer line? Vei No ,2^
Number of new roof draini? o
Imtalt/alter woter line? »
Number of new water heater»?~..-.,~«.„...... O
O Number of new, relocated or repiaced gm outlets?.
Numlser of new Kiose bibi?
Upgrade existing panel? ........ ................. Ves, _X_ No
From K^O Amps to IAmps
Number of new panels or subpanek? j£=r
Single Ph«e Numberof new amperes
Three Pha»e..«.«..««..«.«..««...... Number of new amperes
Three Phase 480 Number of new amperes IP
Remodel (relocate existing outlets/switches or add outlets/switches)?
Ves X No
Number of new furnaces, A/C, or heat pumps? .«M«....««..«„„....«..„«..MM..«.„.««J^,.«..
New or relocated duct worb?..„ Ves X.^ No_
Number of new firepldces? O
Number of new exhaust fans?„,....„.„,M—.M»..«»M..»M...»,....«...,»«.«.,».««M...«.M...«..««.....—...... Q
Relocate/install went?...««..«M..M».....«M..M.M..«....»»M,...«..M-. - „.,„„.,„,.„..„„.,„.„. M)
Number of rtew exhaust hoodJ?....................................................
Number of new boilers or compressors? Number of HP
6-16 Page 1 of 1 Rev. 03/09
10/10'd wv 53:80 f 103-62-100
SAN DIEGO REGIONAL
HAZARDOUS MATERIALS QUESTIONNAIRE
OFFICE USE ONLY
UPFP#
HV#
BP DATE / /
Business Name , Business Contact Telephone #
( )
Project Address , - j State
C/4
Zip Code / APN#
ZiZ'l2o-or~o6 Mailing Address ^ //7^— City" state Zip Code Plan File*
Project Contact Telephone #
The following questions represent the facility's activities, NOT the specific project description.
PART I: FiRE DEPARTIMIENT - HAZARDOUS MATERIALS DIViSION: OCCUPANCY CLASSIFICATION: Indicate by circling the item, whether your business
will use, process, or store any of the following hazardous materials. If any of the items are circled, applicant must contact the Fire Protection Agency with
jurisdiction prior to plan submittal. Facility's Square Footage (including proposed project): Occupancy Rating:
1. Explosive or Blasting Agents 5. Organic Peroxides 9. Water Reactives 13. Corrosives
2. Compressed Gases 6. Oxidizers 10. Cryogenics 14. Other Health Hazards
3. Flammable/Combustible Liquids 7. Pyrophorics 11. Highly Toxic or Toxic Materials 15. None of These.
4. Flammable Solids 8. Unstable Reactives 12. Radioactives
PART II: SAN DiEGO COUNTY DEPARTMENT OF ENVIRONIVIENTAL HEALTH - HAZARDOUS IVIATERIALS DIVISIONS (HiWDl: If the answer to anv of the
questions is yes, applicant must contact the County of San Diego Hazardous Materials Division, 5500 Overland Ave., Suite 110, San Diego, CA 92123.
Call (858) 505-6700 prior to the issuance of a building permit.
FEES ARE REQUIRED. Project Completion Date: / / Expected Date of Occupancy: /
YES NO
1. •
2. •
3. •
4. •
5. • 9 6. • m 7. • m
I • CalARP Exempt
/ Date Initials
• CalARP Required
/ Date Initials
• CalARP Complete
I
Date Initials
(for new construction or remodeling projects)
Is your business listed on the reverse side of this form? (check all that apply).
Will your business dispose of Hazardous Substances or Medical Waste in any amount?
Will your business store or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds,
200 cubic feet, or carcinogens/reproductive toxins in any quantity?
Will your business use an existing or install an underground storage tank?
Will your business store or handle Regulated Substances (CalARP)?
Will your business use or install a Hazardous Waste Tank System (Title 22, Article 10)?
Will your business store petroleum in tanks or containers at your facility with a total storage capacity equal to
or greater than 1,320 gallons? (California's Aboveground Petroleum Storage Act).
PART iil: SAN DIEGO COUNTY AIR POLLUTiON CONTROL DISTRiCT: If the answer to any of the questions below is yes, applicant must contact the Air
Pollution Control District (APCD), 10124 Old Grove Road, San Diego, CA 92131-1649, telephone (858) 586-2600 prior to the issuance of a building or demolition
permit. Note: if the answer to questions 4 or 5 is yes, applicant must also submit an asbestos notification form to the APCD at least 10 working days prior to
commencing demolition or renovation, except demolition or renovation of residential structures of four units or less. Contact the APCD for more information.
Will the subject facility or construction activities include operations or equipment that emit or are capable of emitting an air contaminant? (See the
APCD factsheet at http://www.sdapcd.orq/info/facts/permits.pdf. and the list of typical equipment requiring an APCD permit on the reverse side
ofthis ft-om. Contact APCD if you have any questions).
(ANSWER ONLY IF QUESTION 1 IS YES) Will the subject facility be located within 1,000 feet of the outer boundary of a school (K through 12)?
(Search the California School Directory at http://www.cde.ca.qov/re/sd/ for public and private schools or contact the appropriate school district).
Has a survey been performed to determine the presence of Asbestos Containing Materials?
Will there be renovation that involves handling of any friable asbestos materials, or disturbing any material that contains non-friable asbestos?
Will there be demolition involving the removal of a load supporting structural member?
YES NO
1. •
2. • •
3. •
4. •
5. •
Briefly describe business activities: Briefly describe proposed project:
I declare under penalty of perjury that tq the best of my knowledge and belli
TA^/r HO I^UN •
Name of Owner or Authorized Agent
l^'WUch Im^fKiuv^j (MHI'CWS^ ^leci/<)Mi^ l^lhci^)M >j f^iJi^H
Date
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION:.
BY:
FOR OFFICIAL USE ONLY
DATE:
EXEMPT OR NO FURTHER INFORMATION REQUIRED RELEASED FOR BUILDING PERMIT BUT NOT FOR OCCUPANCY RELEASED FOR OCCUPANCY
COUNTY-HMD* APCD COUNTY-HMD APCD COUNTY-HMD APCD
*A stamp in this box onlv exempts businesses from completing or updating a Hazardous Materials Business Plan. Other permitting requirements may still apply.
HM-9171 (02/11) County of San Diego - DEH - Hazardous Materials Division
CB142661 1808 ASTON AV 185
N-TENT, 4000 SF OFFICE TO
nFFICF
Final Inspection required by:
• Plan • CM&I
Approved Date By
BUILDING
PLANNING io| 1^(1-/
ENGINEERING
FIRE Expedite? 0 N l(/ i^//W
DIGITAL FILES Required? Y N
HazMat
APCD 'If 1 f
Health
Forms/Fees Sent Reed Due? By
sw •ISSUED •cv.
Encina
Fire
HazHealthAPCD
PE&M
School
Sewer
Stormwater
Special Inspection
CFD: Y N
LandUse: Density: ImpArea: FY: Annex: Factor:
PFF: Y
Comments Date Date Date
Building
Planning
Engineering
Fire
Need?
• Done
• Done
• Done
• Done