11/18/1999 CommercialllndustriaI Permit Permit No: CB993641
Building Inspection Request Line (760) 438-3101
Job Address: 181 2 ASTON AV CBAD
Permit Type: TI
Parcel No: 2121200600 Lot #: 0 Status: ISSUED
Valuation: $75,000.00 Construction Type: VN Applied: 10/01/1999
Occupancy Group:
Project Title: ACUSHNET-3,850 SF OFFICE,
4860 SF NEW TRUCK WELLS,15.920 SF MFG TO WRHSE Issued: 11/18/1999
Plan Approved: 10/22/1999
Sub Type: INDUST
Reference #: Entered By: RMA
Applicant:
PETER BUSSETT
STE 200
12220 EL CAMINO REAL C" 867.58
SAN DlEGO CA 92130 858 793-4777
Inspect Area: Owner:
Building Permit
Plan Check
Add'l Plan Check Fee
Plan Check Discount
Strong Motion Fee
Park Fee
LFM Fee
Bridge Fee
BTD #2 Fee
BTD #3 Fee
Renewal Fee
Add'l Renewal Fee
Other Building Fee Pot. Water Con. Fee $0.00 MECHANICAL TOTAL
Meter Size
Add'l Pot. Water Con. Fee
Red. Water Con. Fee
Master Drainage Fee:
$0.00 Sewer Fee:
$0.00 Redev Parking Fee: TOTAL PERMIT FEES
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$0.00
$125.00
$160.00
$55.00
$0.00
$0.00
$1,200.27
$0.00
Date:
NOTICE Please take NOTICE that approval of your project includes the'lmpasition' of fees, dedications, reservations, or other exadons hereafter wllectively
follow the protest procedures set forth in Government Code Section 66020(a), and filethe protest and any other required information with the City Manager for
referred to as "feeslexadbns." You have 90 days from the date this permid was issued to protest imposition of these feeslexactions. If you protest them, you must
processing in accordance with Cadsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any SubeqUent legal action to attack,
review, set aside, void, or annul their imposition.
You are hereby FURTHER NOTIFIED that your right to prolest the specMed feeslexactions DOES NOT APPLY to water and sewer wnnection fees and apady
changes, nor planning, zoning, grading or other similar application pmeessing or sewia fees in wnnection with this project NOR DOES IT APPLY to any
feeslexactions of which YOU have previously been uiven a NOTICE similar to lhis, cmas to which the statute of limitations has previouslv othewise expired.
CITY OF CARLSBAD
2075 Las Palmas Dr., Carlsbad, CA 92009 (760) 438-1161
Inspection List
Permit# CB993641 Type: TI INDUST ACUSHNET-3,850 SF OFFICE,
4860 SF NEW TRUCK WELLS,15,920 SF M
Date Inspection Item
07/28/2000 34 Rough Electric
07/28/2000 89 Final Combo
05/24/2000 89 Final Combo
02/03/2000 34 Rough Electric
01/12/2000 89 Final Combo
0111 1/2000 89 Final Combo
01/04/2000 84 Rough Combo
01/03/2000 84 Rough Combo
01/03/2000 89 Final Combo
12/28/1999 84 Rough Combo
12/27/1999 84 Rough Combo
11/24/1999 15 Roof/Reroof
11/24/1999 17 Interior LathlDrywall
11/23/1999 14 Frame/SteeVBoltingMIeldin
11/23/1999 34 Rough Electric
Inspector Act Comments
PD AP
PD AP
PD co ON CARD
PD co INCOMPLETE
PD co SEE NOTICE ATTACHED
TP CA RE-SCHD FOR 1/12/00
PD AP ON 1/3/00
PD AP CEILING
PD co
PD co
PD CA
PD wc
PD wc
PD AP
PD AP
Tuesday, April 23, 2002 Page 1 of 1
City of Carlsbad Bldg Inspection Request
For: 7/28/2000
Permit# CB993641 Inspector Assignment: PD
Title: ACUSHNET-3,850 SF OFFICE,
Description: 4860 SF NEW TRUCK WELLS,15,920 SF MFG TO WRHSE
Type:TI Sub Type: INDUST
Job Address: 1812 ASTON AV
Suite: Lot 0
Location:
APPLICANT PETER BUSSEIT
Owner: COBRA-BLACKMORE
Remarks: REQUESTED AN ELECTRIC INSPECTION
Phone:
Total Time: Requested By: LUIS
Entered By: CHRISTINE
CD Description Act Comments
34 Rough Electric
ssociated PCRs
Date DeSdPtiOn
JnsDection History
Act lnsp Comments
y24/2000
2/3/2000
1/12/2000
1/11/2000
1/4/2000
1/3/2000
1/3/2000
12/28/1999
12/27/1999
1 1 /24/1999
11/24/1999
11/23/1959
11/23/1999
89 Final Combo
34 Rough Elect'ic
89 Final Combo
89 Final Combo
84 Rough Combo
84 Rough Combo
89 Final Combo
84 Rough Combo
84 Rough Combo
15 RwWRerwf
14 Frame/SteeliBoltingNelding
17 Interior Latmrywall
34 Rough Elect'ic
CO PD ONCARD
CO PD INCOMPLETE
CO PD SEE NOTICE ATACHED
AP PD ON 1/3/00
CA TP RE-SCHD FOR 1/12/00
AP PD CEILING
CO PD
CO PD
CA PD
WC PD
WC PD
AP PD
AP PD
City of Carlsbad Bldg Inspection Request
For: 1/12/2000
Permit# CB993641 Inspector Assignment: PD
Title: ACUSHNET-3,850 SF OFFICE,
Description: 4860 SF NEW TRUCK WELLS,15,920 SF MFG TO WRHSE
Type: TI Sub Type: INDUST
Job Address: 1812 ASTON AV
Suite: Lot 0
Location:
APPLICANT PETER BUSSETT
Owner: COBRA-BLACKMORE
Remarks: RESET FROM TUES- BRING OUT CITY AP PLANS
Phone: 6192472493
Inspector: &
Total Time: Requested By: JOHN
Entered By: CHRISTINE
CD Description Act Comments
19 Final Structural
29 Final Plumbing
39 Final Electrical
49 Final Mechanical
Associated PCRs
Date Description
InsDection History
Act lnsp Comments
1/11/2000
1/4/2000
1/3/2000
1/3/2000
12/28/1999
12/27/1999
11/24/1999
11/24/1999
11/23/1999
11/23/1999
89 Final Combo CA TP RE-SCHD FOR 1/12/00
84 Rough Combo AP PD ON 1/3/00
84 Rough Combo AP PD CEILING
89 Final Combo CO PD
84 Rough Combo CO PD
84 Rough Combo CA PD
15 RwWRerwf WC PD
17 Interior Lath/Drywall WC PD
14 FramelSteeWBoltingIding AP PD
34 Rough Electric AP PD
SHEATHING
0 FRAME
0 ROUOH PLUMBING
0 SEWER AND WCO.
o TOP OUT PLUMBIAG
I"
INSPECTOR
..
Cerlabad 99-3641 October 15, 1999
SPECIAL INSPECTION PROGRAM
nDDRESS OR LEGAL DESCRIPTION: 1812 Aston Ave. , ~~ ~~
agent of the owner (contractors may not employ the special inspector),
inspector(s) as req rm Building Code (UBC) Section 1701.1 fer the con-struction
'mer of resord, will be responsible for employing the special
project located at above. UBC Section 106.3.5.
I, as the engine&chitect of record. certify that I have prepared :he following special inspection program as required by UBC Section 106.3.5 for the construction project located at
the site listed above.
Signed
1. List of work requiring special inspection:
8
8
Soils Compliant* Prior to Foundation inspection
Structural Concrete Over 2500 PSI 0 Prestressed Concrete
Structural Masonry
Designer Specifled
a FfeM Weld n High Strength Bolting 0 Expansidkpoxy Anchors 0 Sprayedan Fireproofing u Other
2, Name(s) of iadividual(s) or firm&) responsible for the special inspections listed
above:
E.
C.
3. Duties of the special inspectors for the work listed above:
- EsGil Corporation
In Tannerstlip witfi +vernnunt for BuiHing Safety
DATE: October 21, 1999
JURISDICTION: Carlsbad
PLAN CHECK NO.: 99-3641 SET: I1
ANT
0 PLAN REVIEWER
0 FILE
PROJECT ADDRESS: 1812 Aston Ave.
PROJECT NAME: T. I. for Acushnet Company
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
[XI The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
0 The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
0 The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
0 The applicant's copy of the check list has been sent to:
0 Esgil Corporation staff did not advise the applicant that the plan check has been completed.
Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted:
Date contacted: Fax #:
Mail Telephone Fax In Person
REMARKS: 1. Building inspection program. 2. Require
Architect to provide a construction work proposed
under this permit. 3. city. Okd by Mike P.
By: Abe Doliente Enclosures:
Esgil Corporation 0 GA 0 MB EJ 0 PC 10121 199 tmsmtl.dot
9320 Chesapeake Drive, Suite 208 SanDiego, California 92123 (858) 560-1468 + Fax (858) 560-1576
EsGil Corporation 7 -
Zn Tnrtnership with government far !Buil&flSnfety
DATE: October 15, 1999
JURISDICTION: Carlsbad
PLAN CHECK NO.: 99-3641
PROJECT ADDRESS: 1812 Aston Ave
PROJECT NAME: T. I. for Acushnet Company
a PLAN REVIEWER
0 FILE
SET: I
0 The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
0 The plans transmitted herewith will substantially comply with the jurisdiction's building codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
[XI The check list transmitted herewith is for your information. The plans are being held at Esgil
Corporation until corrected plans are submitted for recheck.
0 The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Peter Bussett
12220 El Camino Real, Suite 200, San Diego, CA 92130
Esgil Corporation staff did not advise the applicant that the plan check has been completed.
0 Esgil Corporation staff did advise the applicant that the plan check has been completed.
Person contacted: Telephone #:
Date contacted: (by: 1 Fax #: 793-4787
Mail Telephone Fax In Person 0 REMARKS:
By: Abe Doliente Enclosures:
Esgil Corporation 0 GA MB 0 EJ 0 PC 1015199 tmsrntl.dot
9320 Chesapeake Drive, Suite 208 + SanDiego, California 92123 + (858) 560-1468 + Fax (858) 560-1576
Carlsbad 99-3641
October 15, 1999
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
CCUPANCY: B/S-1 USE: Office, warehouse
TYPE OF CONSTRUCTION: V-N ACTUAL AREA: no change
ALLOWABLE FLOOR AREA: unlimited STORIES: 2
HEIGHT:
SPRINKLERS?: Yes OCCUPANT LOAD: 71
ATE PLANS RECEIVED BY DATE PLANS RECEIVED BY
URISDICTION: ESGlL CORPORATION: 10/5/99
ATE INITIAL PLAN REVIEW PLAN REVIEWER: Abe Doliente
FOREWORD (PLEASE READ):
This plan review is limited to the technical requirements contained in the Uniform Building Code,
Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws
regulating energy conservation, noise attenuation and access for the disabled. This plan review
is based on regulations enforced by the Building Department. You may have other corrections
based on laws and ordinances enforced by the Planning Department, Engineering Department,
Fire Department or other departments. Clearance from those departments may be required
prior to the issuance of a building permit.
Code sections cited are based on the 1997 UBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 106.4.3,
1997 Uniform Building Code, the approval of the plans does not permit the violation of any
state, county or city law.
To sDeed UD the recheck Drocess. Please note on this list for a CODV) where each
correction item has been addressed, Le., Plan sheet number. sPecification section, etc.
Be sure to enclose the marked UP list when YOU submit the revised plans.
TENANT IMPROVEMENTS WITHOUT SPECIFIC ENERGY DATAOR POLICY SUPPLEMENTS (1997UBC) lifonv.dot
Carlsbad 99-3641
October 15, 1999
Please make all corrections on the original tracings, as requested in the correction list.
Submit three sets of plans for commerciaVindustria1 projects. For expeditious processing,
corrected sets can be submitted in one of two ways:
1. Deliver all corrected sets of plans and calculationslreports directly to the City of
Carlsbad Building Department. 2075 Las Palmas Drive, Carlsbad, CA 92009, (760) 438-
1161. The City will route the plans to EsGil Corporation and the Carlsbad Planning,
Engineering and Fire Departments.
2. Bring one corrected set of plans and calculations/reports to EsGil Corporation,
9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468. Deliver all
remaining sets of plans and calculationslreports directly to the City of Carlsbad Building
Department for routing to their Planning, Engineering and Fire Departments.
reviewed by the City Planning, Engineering and Fire Departments until review by EsGil
Corporation is complete.
NOTE: Plans that are submitted directly to EsGil Corporation only will not be
1.
2.
3.
4.
5.
6.
7.
Plans and calculations shall be signed by the California state licensed engineer
or architect where there are structural changes to existing buildings or structural
additions. Please include the California license number, seal, date of license
expiration and date plans are signed. Business and Professions Code.
UBC Section 107.2 requires the Building Official to determine the total value of
all construction work proposed under this permit. The value shall include all finish
work, painting, roofing, electrical, plumbing, heating, air conditioning, elevator,
fire extinguishing systems and any other permanent equipment. Please provide
the designer's or contractor's construction cost estimate of all work proposed.
Note on plan that suspended ceilings shall comply with UBC Tables 25-A, 16-0
and 16-B.
The tenant space and new and/or existing facilities serving the remodeled area
must be accessible to and functional for the physically disabled. See the
attached correction sheet. Title 24.
MISCELLANEOUS
Field welding is shown on the plans. This requires special inspection. When
special inspection is required, the architect or engineer of record shall prepare an
inspection program which shall be submitted to the building official for approval
prior to issuance of the building permit. Please complete the attached form.
The Documentation Author and the Principal Lighting Designer must sign the
LTG-1 form.
Please see the following corrections for electrical.
Carlsbad 99-3641
October 15, 1999
8. To speed up the review process, note on this list (or a copy) where each
correction item has been addressed, i.e., plan sheet, note or detail number,
calculation page, etc.
9. Please indicate here if any changes have been made to the plans that are not a
result of corrections from this list. If there are other changes, please briefly
describe them and where they are located in the plans.
Have changes been made to the plans not resulting from this correction list?
Please indicate:
Yes 0 No 0
The jurisdiction has contracted with Esgil Corporation located at 9320
Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of
858/560-1468, to perform the plan review for your project. If you have any
questions regarding these plan review items, please contact Abe Doliente at
Esgil Corporation. Thank you.
+ ELECTRICAL PLAN REVIEW + 1996 NEC
+ PLAN REVIEWER: MORTEZA BEHESHTI
1. Specify the wire type (AL or CU) and insulation (i.e. THWN). NEC 310.
2. Specify the wiring method you intend to use for this project (i.e., EMT, Metal
Flex, NMC etc.). NEC 110-3(a) and (b)
3. Provide a panel schedule for panel "BPG" shown on sheet E-I to be used for the
emergency lights power.
4. Provide GFI protected receptacle(s) within 25 feet of HVAC equipment. NEC
210-8(b)2 & 210-63
5. Provide a minimum of 1 foot-candle of emergency illumination at the floor level
and specify a second source of power for the emergency illumination (battery or
generator). UBC 1003.2.9 & NEC 700-16.
Note: If you have any questions regarding this electrical plan review list please contact
Morteza Beheshti at (619) 560-1468. To speed the review process, note on this
list (or a copy) where the corrected items have been addressed on the plans.
10. I 1 I
RIGHI FEET
20 0 IO 20 30 40 50 60 70 00
10
FEET DOWN 20 0 10 20-
6V 12W PAR36 (H7553)
20
FEET
LEFT
0
FEET RIGHT 20 DOWN F7!!!!E FEET 20 0 20
12V 18W PAR36 (4414)
Siltron Illumination, Inc.
P.O. Box 280
7915 Center Avenue
Cucamonga, CA 91730
(714) 941-3500 Fax: (714) 983-4476
BUILDING PLANCHECK CHECKLIST
DATE: /$&/% PLANCHECK NO.: CB 79.3'6 L//
BUILDING ADDRESS: 16r2 Ash A"
PROJECT DESCRIPTION: 7-z
ASSESSORS PARCEL NUMBER: 0212 -lao-oL EST. VALUE:
ENGINEERING DEPARTMENT
APPROVAL DENIAL
The item you have submitted for review has been approved. The approval is based on plans, marked with 0. Make necessary corrections to plans
Please see the attached report of deficiencies
information andlor specifications provided in your or specifications for compliance with applicable submittal: therefore any changes to these items after codes and standards. Submit corrected plans andlor this date, including field modifications, must be specifications to this office for review. reviewed by this office to insure continued conformance with applicable codes. Please review carefully all comments attached, as failure to comply with instructions in this report can result in suspension of permit to build. By: Date:
w Right-of-way permit is required prior to
.construction of the following improvements: By: Date:
By: Date:
Dedication Application
Dedication Checklist
Improvement Application
improvement Checklist
Future Improvement Agreement
Grading Permit Application
Grading Submittal Checklist
Right-of-way Permit Application
Right-of-way Permit Submittal Checklist and Information Sheet
Sewer Fee Information Sheet
Name: JOANNE JUCHNIEWICZ
City of Carlsbad
Address: 2075 Las Palmas Dr., Carlsbad. CA 92009
Phone: (619) 438-1161, ext. 4510
CFD INFORMATION
Parcel Map No:
Lots:
Recordation:
Carlsbad Tract:
A-4
BUILDING PLANCHECK CHECKLIST
fr 3RD'
Po
SITE PLAN
0 1. Provide a fully dimensioned site plan drawn to scale. Show:
A. North Arrow D. Property Lines
B. Existing & Proposed Structures E. Easements
C. Existing Street Improvements F. Right-of-way Width & Adjacent Streets
G. Driveway widths
0 2. Show on site plan:
A. Drainage Patterns
1. Building pad surface drainage must maintain a minimum slope of one
percent towards an adjoining street or an approved drainage course.
2. ADD THE FOLLOWING NOTE: "Finish grade will provide a minimum positive
drainage of 2% to swale 5' away from building."
B. Existing & Proposed Slopes and Topography
3. Include on title sheet:
/ A. Site address
B. Assessor's Parcel Number
C. Legal Description
For commerciallindustrial buildings and tenant improvement projects, include:
total building square footage with the square footage for each different use,
existing sewer permits showing square footage of different uses (manufacturing,
warehouse, office, etc.) previously approved.
EXISTING PERMIT NUMBER PeA ex iJJh & CQ
r, d\? kb4SiUds.Q
DESCRIPTION
J
-mmd u4y. ~TRb-CJrJ - P
C.=3b&,S~so&-L
DISCRETIONARY APPROVAL COMPLIANCE
0 0 0 4a. Project does not comply with the following Engineering Conditions of approval for
Project No.
a a 0 4b. All conditions are in compliance. Date:
2
BUILDING PLANCHECK CHECKLIST
,&' ;ND/ 3RD/ DEDICATION REQUIREMENTS
0 5. Dedication for all street Rights-of-way adjacent to the building site and any storm
drain or utility easements on the building site is required for all new buildings and
for remodels with a value at or exceeding $ , pursuant to Carlsbad
Municipal Code Section 18.40.030.
Dedication required as follows:
~~~ ~~ ~ ~
Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8 %" x 11" plat map
and submit with a title report. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. Attached please find an application form and submittal checklist for the dedication process. Submit the completed application form with the required checklist items and fees to the Engineering Department in person. Applications be accept by mail or fax.
Dedication completed by: Date:
IMPROVEMENT REQUIREMENTS
0 6a. All needed public improvements upon and adjacent to the building site must be
constructed at time of buildina construction whenever the value of the
construction exceeds $ Section 18.40.040.
I , pursuant to Carlsbad Municipal Code
Public improvements required as follows:
Attached please find an application form and submittal checklist for the public improvement requirements. A registered Civil Engineer must prepare the appropriate improvement plans and submit them together with the requirements on the attached checklist to the Engineering Department through a separate plan
checklist must be submitted in person. Applications by mail or fax are not
check process. The completed application form and the requirements on the
accepted. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of building permit.
Improvement Plans signed by: Date:
0 0 0 6b. Construction of the public improvements may be deferred pursuant to Carlsbad
current grant deed on the property and processing fee of $
Municipal Code Section 18.40. Please submit a recent property title report or
so
we may prepare the necessary Future Improvement Agreement. This agreement must be signed, notarized and approved by the City prior to issuance of a
Building permit.
Future public improvements required as follows:
3
BUILDING PLANCHECK CHECKLIST
,SI/
0
0
0
0
0
2nd/ 3d‘
0 0
0 0
P 0
0 0
6c. Enclosed please find your Future Improvement Agreement. Please return
agreement signed and notarized to the Engineering Department.
Future Improvement Agreement completed by:
Date:
6d. No Public Improvements required. SPECIAL NOTE: Damaaed or defective
improvements found adiacent to buildina site must be repaired to the satisfaction
of the Citv Inspector prior to occupancy.
GRADING PERMIT REQUIREMENTS
The conditions that invoke the need for a grading permit are found in Section
11.06.030 of the Municipal Code.
7a. Inadequate information available on Site Plan to make a determination on grading
requirements. Include accurate grading quantities (cut, fill import, export).
7b. Grading Permit required. A separate grading plan prepared by a registered Civil
Engineer must be submitted together with the completed application form
attached. NOTE: The Gradina Permit must be issued and rouah aradinq
amroval obtained prior to issuance of a Buildina Permit.
Grading Inspector sign off by: Date:
0
0 0
0 0
0 0
0 0
7c. Graded Pad Certification required. (Note: Pad certification may be required even
if a grading permit is not required.)
7d.No Grading Permit required.
7e.lf grading is not required, write “No Grading” on plot plan.
MISCELLANEOUS PERMITS
8. A RIGHT-OF-WAY PERMIT is required to do work in City Right-of-way andlor
private work adjacent to the public Right-of-way. Types of work include, but are
not limited to: street improvements, tree trimming, driveway construction, tieing
into public storm drain, sewer and water utilities.
Right-of-way permit required for:
2nd" 3d'
0 0 9. A SEWER PERMIT is required concurrent with the building permit issuance. The
0 0 10. INDUSTRIAL WASTE PERMIT If your facility is located in the City of Carlsbad
fee is noted in the fees section on the following page.
sewer service area, you need to contact the Carlsbad Municipal Water District,
located at 5950 El Camino Real, Carlsbad, CA 92008. District personnel can
provide forms and assistance, and will check to see if your business enterprise is
on the EWA Exempt List. You may telephone (760) 438-2722, extension 153, for
assistance.
Industrial Waste permit accepted by:
Date:
0 0 11. NPDES PERMIT
Complies with the City's requirements of the National Pollutant Discharge
Elimination System (NPDES) permit. The applicant shall provide best
management practices to reduce surface pollutants to an acceptable level prior to J-
discharge to sensitive areas. Plans for such improvements shall be approved by
the City Engineer prior to issuance of grading or building permit, whichever
occurs first.
12. 2= quired fees are attached
No fees required
0 0 0 13. Additional Comments:
5
PLANNING DEPARTMENT
BUILDING PLAN CHECK REVIEW CHECKLIST * 3
+dEE & Bp"
Plan Check No. C
Planner Phone (61 9) 438-1 161 , extension-
APN: 12- !7D - QG
Zoning: General Plan: Facilities Management Zone: 5-
CFD hind # "- Date of participation: -- Remaining net dev acres: -
Apk-,
Address /g/ /&dt@l &,
2 2 Type of Project & Use:- Net Project Density: s 7 DU/AC
Circle One -
(For non-residential development: Type of land used created by
this permit: 1
bB 6:
Leaend: a Item Complete (a Item Incomplete - Needs your action
Environmental Review Required: YES - NO - TYPE
DATE OF COMPLETION:
Compliance with conditions of approval? If not, state conditions which require action.
Conditions of Approval:
@no
0 Discretionary Action Required: YES - NO - TYPE
APPROVALIRESO. NO. DATE
PROJECT NO.
OTHER RELATED CASES:
Compliance with conditions or approval? If not, state conditions which require action.
Conditions of Approval:
0 Coastal Zone AssessmentlCompliance
Y Project site located in Coastal Zone? YES - NO-
CA Coastal Commission Authority? YES-
If California Coastal Commission Authority: Contact them at * 3111 Camino Del Rio North, Suite
200. San Diego CA 92108-1725; (619) 521-8036
Determine status (Coastal Permit Required or Exempt):
Coastal Permit Determination Form already completed? YES- NO
If NO, complete Coastal Permit Determination Form now.
Coastal Permit Determination Log #:
NO-
-
Follow-Up Actions:
1) Stamp Building Plans as "Exempt" or "Coastal Permit Required" (at minimum
2) Complete Coastal Permit Determination Log as needed.
Floor Plans).
& 0 0 lnclusionary Housing Fee required: YES - NO -
Data Entry Completed? YES - NO
[Effective date of lnclusionary Housing Ordinance - May 21, 1993.)
IAIPIDs. Activity Maintenance. enter CBX. toolbar. Screens. Housing Fees. Construct Housing YIN, Enter Fee, UPDATE!) -
Site Plan:
1. Provide a fully dimensional site plan drawn to scale. Show: North arrow,
property lines, easements, existing and proposed structures, streets, existing
street improvements, right-of-way width, dimensional setbacks and existing
topographical lines.
2. Provide legal description of property and assessor's parcel number.
Zoning: 8 0 1. Setbacks:
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
0 2. Accessory structure setbacks:
Front: Required Shown
Interior Side: Required Shown
Street Side: Required Shown
Rear: Required Shown
Structure separation: Required Shown
.$n3 c] 3. Lot Coverage:
fin 0 4. Height:
Required Shown
Required Shown
c] 0 5. Parking: Spaces Required Shown
Guest Spaces Required Shown
0 Additional Comments
nn
OK TO ISSUE AND ENTERED APPROVAL INTO COMPUT
Carlsbad Fire Department 990374
2560 Orion Way Fire Prevention
Carlsbad, CA 92008 (760) 931-2121
Plan Review Requirements Category:
Date of Report: 1117/1999
Name: SMITH CONSULT ARCH
Address: 12220 EL CAMINO REAL STE 200
City, State: SAN DlEGO CA 92130
Plan Checker:
Job Name: Acushnet Company Bldg #: CB993641
Job Address: 1812 Aston Av Ste. or Bldg. No.
Job #: 990374
lz Approved The item you have submitted for review has been approved. The approval is
based on plans, information and I or specifications provided in your submittal;
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
0 Approved
Subject to
0 Incomplete
The item you have submitted for review has been approved subject to the
attached conditions. The approval is based on plans, information andlor
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and I or specifications required to indicate
compliance with applicable codes and standards.
The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and I or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and I or specifications to this
office for review and approval.
Review 1st 2nd 3 rd Other Agency ID
FD Job # 990374 FD File #
Garlsbad Fire Department 990374
2560 Orion Way Fire Prevention
Carlsbad, CA 92008 (760) 931-2121
Plan Review Requirements Category: Building Plan
Date of Report: 10’05/1999 Reviewed by: (1, &d-
Name: SMITH CONSULT ARCH
Address: 12220 EL CAMINO REAL STE 200
Plan Checker: Job #: 990374
Job Name: Acushnet Company Bldg #: CB993641
Job Address: 1812 Aston Av Ste. or Bldg. No.
0 Approved The item you have submitted for review has been approved. The approval is
based on plans, information and / or specifications provided in your submittal:
therefore any changes to these items after this date, including field
modifications, must be reviewed by this office to insure continued conformance
with applicable codes and standards. Please review carefully all comments
attached as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements.
0 Approved The item you have submitted for review has been approved subject to the
Subject to attached conditions. The approval is based on plans, information and/or
specifications provided in your submittal. Please review carefully all comments
attached, as failure to comply with instructions in this report can result in
suspension of permit to construct or install improvements. Please resubmit to
this office the necessary plans and / or specifications required to indicate
compliance with applicable codes and standards.
Incomplete The item you have submitted for review is incomplete. At this time, this office
cannot adequately conduct a review to determine compliance with the
applicable codes and / or standards. Please review carefully all comments
attached. Please resubmit the necessary plans and / or specifications to this
office for review and approval.
Review 1 st 2nd 3rd Other Agency ID
FD Job # 990374 FD File #
Rgquirements Category: Building Plan
Requirement: Pending 05.14 Provide Technical Report
To determine the acceptability of technologies, processes, products, facilities, materials and uses
attending the design, operation or use of a building or premises subject to the inspection of the
department, the Chief is authorized to require the owner or the person in possession or control of the
building or premises to provide, without charge to the jurisdiction, a technical opinion and report. The
opinion and report shall be prepared by a qualified engineer, specialist, laboratory or fire-safety
specialty organization acceptable to the Chief and the owner and shall analyze the fire-safety
properties of the design, operation or use of the building or premises and the facilities and
appurtances situated thereon, to recommend necessary changes.
Page 1 10/05/99
.. .
.. .
STRUCTURAL'
CAI CULATIONS
PRIME STRUCTURAL ENGINEERS
16980 Via Tazon. Suite 260
San Diego, California 92127
Tel (619) 487-031 1
.
hl=
I h2=
ap=
Ip=
<-1 st Flr ' Rp=
r
Soil Profile Type =
Near Source Factor Na=
Ca =
Fp =
Fp =
Fp =
Fp =
Total Seismic Load=
Roof Reaction =
Base Reaction =
Maximum Moment =
Maximum Moment occurs =
for Wall Design
20.00 R Seismic source type = 2
3.00 R (A=I, B=2, C=3)
1 .oo
1 .oo
3.00
4
1 .o
0.44
0.15
0.587
0.308
0.653
9.82
6.54
3.28
Closest distance = 10 km
(SA=I, SB=Z,SC=3,SD=4,SE=5)
(When soil properties not known, use Type SD
per section 1629.3. Exception)
(iNa >1.1. check w/section 1629.4.2 for special condition)
'(l+3'hxlhr)Wp 0.7*Ca9lp= 0.308
4'Ca'lp= 1.76
'Wp athx=hr
* Wp for hx=O to hx= 7.2 ft
Wp at top of wall
WP
WP
WP
Where Wp=weight of wall psf
17.67 Wp-ft
10.40 R from base
Q=3m w eq= 8' Max.
hrA2
~.
.. . .
~..
. ._i, ., . ~. 1' s# ~, " i:<rt-r: I ,,ll:, i:;;;:;. ;:.
." ..... .,. . ,.
[<!!!:;::I!: .. PRECAST CONCRETE ...... ~ykci L:Es!+ : ; .. , ............. ........... .. ..... .... .../.,I........... .. ,. Considering P-Delta. Effects ' ' .... .. , 1 .. ...... ..... ........ ...... z i I i23EAOC "Green Book" To iterate P-Delta effects to convergence F, !, j.7, T i i ' : ,:*x ,_ ..
..... ...... . , ?.I. , . I . ...... :l.j..j(. ........... ... ......... .. ......... .. using 1997 UBC Load factors. ..
:I :; .: 1: .
... ......, i/: .i. .... /!!j. . ..
,i.:i;ititi!f!iil!ii .: . ,
........ ........
~ ~~ ~ DESCRIPTION:
,, !:t::itt!i ..
PANEL N-3
PIER B ,....
.I./, .
~ ~~ ~
.... ....
.... DESlGN DATA: ~~
..;..,. .~ ~
................. ........... ~ ."" ~ PC= 3,000 psi Min.Vert. Steel % = 0.0025 Clear Wall Ht = 20 n
Fy= 60,000 psi Min. Horiz. Steel % = 0.0015 Total wall Ht = 23 it
Phi=
Seismic Factor=
Wind Load=
Reveal Depth=
Reveal to Bot=
Wall Thk.=
Rebar Size # =
Rebar Spacing=
Depth to steel=
Rebar @ Reveal=
d @ Reveal=
Steel @ea. face=
0.87 Max Vet. Spacing= 18.00 in HVThk Ratio=
0.353 Max Horiz. Spacing = 16.30 in Eccentric Dead Load =
18.6 psf Beta1 = 0.85 Eccentric Live Load =
0.75 in 0.6 x Rhow Balance = 0.0128 Load Eccentricity =
9 ft Shall LL be used with laterial load combination? Y=l,N=O->
Additional ImRosed Loads:
18 in Axial Unform DL= 4549 plf Point Lateral Load =
6 Axial Uniform LL= 0 plf X-dist. to Bottom =
6 n o.c.Unform Lateral Load = 127 plf Seismic=l. Wind=2->
15.25 in X-dist. to Bottom = 9.5 ft
7.5 O.C. X-dist. to top = 23 ft
5.75 in Seismic=l, Wind=2-> 1
2 (1 for single layer, 2 for double layers) .
13.3
224 plf
280 plf
11 in
0
79.42 #
14.5 ft
1
LATERAL LOADINGS Wl.32D + 0.55L + 1.lE)) for seismic load combination.
U=0.75(1.4D+1.7L+l.NV) for Wind Load Combination.
~~~~ ~~ ~ ~
Wallwt. = 225.0 psf Wind Load x 1.275= 23.7
Seismic Service= 79.4 psf Factored Seismic = 67.4
.,- .. .. .. ... ........ : .~ .:=.; : ~ ............. ._.- ~ ... I,
....... , ./ :. :, .i ..., ..... ..... PRECASTCONCRETEWALUD ... t.$ SIGN: .. : ., : :
*111,, .... r :: , ; :%~i 7 , . ' . Considering P-Delta E+&.. .?.'.:: '. ::/ ':": .... ?>,1ii,,:!'i'.A* . .j:: SEAOC "Green Book" @~ifq@teiF!-belta effects to convergence
.... ... ..
..... .. .... .,. using 1997 UBC Load factors. .... ...
., . .. 1,!,, ...,.... .. ...... ,. ....... DESCRIPTION; .: 5 1 PANEL N-3
"" ... -_ "" ............. ,.. .. ..~~
.. PIER B
VERTICAL
Loading
P axial = 224
P wall = 7,182
Pu-Axial= 296
Pu-Wall= 9,480
Pu-Total= 9,775
PIA= 34.30
ANALYSIS:
As(eft)=[Pu:tot + (As'Fy)YFy =
' a'=(As'Fy+Pu)/(0.85'fc*l2) =
Phi =0.9 - Z'Pul(fc*Ag)=
Mn=As(eR)'ry'(d-aL?)=
Mu= Phi'Mn=
I,,, c=alBeta=
E=57000'(f~)~0.5=
n=29MX)lEc=
Fr=5'(fc)*0.5=
Gross section modulus=
Mcr (cracked Moment Cap.)=
I gross =
I cracked =
..
VERTICAL
@Reveal Loading
224 224
7,699 7249
38.30 34.60
296 235
10,163 761 1
10.458 7847
SNSMIC COMBlNATlQN
Atwed
1.043
2.045
2.406
0.87
751,214
653,428
3.1E+ffi
9.29
273.9
648.0
177,462
5832.0
1661.1
..
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
@Reveal
224 plf
7699 plf I
38.30 psi 0.04*fc= 120.00 psi
235 plf
8084 plf
8319 plf
WIND COMBlNATlON
Atwed
1.011
1.982
2.332
0.88
752.877
659,356
3.1E+06
9.29
273.9
848.0
177.462
5832.0
1624.1
N.A
N.A
N.A
N.A
(47,835)
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
inA2/R
in
in
In#
in#
psi
Psi
inA3
in#
inA4
inA4
... ..
it ii !t ..
... ........ ........ ..... :;... ...
.,',
,,,,.!r:.i:il .~ . ~ . ., ., ~ . ., I ............ ,,,,,,!!,:E*,,: .. ". ... PRECAST CONCRETE.W~L<C;&G~~ 1 . ; !r{f!!!l::i$$i. !:: .~ .................. .. ...., i.l .... i.. .::i/.li .. .~ Considering P-Delta Effekts .,., r. ... .._._. - ~. .... ... :..
.~ ... 1. 3::: :
~, . .: , ., ..... ..__. : : :,;,fSE&OC "Green Book' To iterate P-Delfa.effects to convergence; i i j, j i i : ,>a- . _" 1 : :. .J I ,.
......... ... ....... .... ........... using 1997 UBC Load factors. ,, .
... 3. ..j.i. .. .... !I/ ,..:~::.:~i!lIiit!i: ~
.~ ~ .~ ,)
DESCRIPTION:
,, ,,.,:;l::;ll!: .. ,,, ,
PANEL N-3
DESlGN DATA:
P c=
Fy=
Phi=
Seismic Factor=
Wind Load=
Reveal Depth=
Reveal to Bot=
.......
Wall Thk.=
Rebar Size # =
Rebar Spacing=
PIER C ..
..............
3,000 psi Min. Vert. Steel % = 0.0025 Clear Wall Ht =
60,000 psi Min. Horiz. Steel Yo = 0.0015 Total wall Ht =
0.88 Max Vet. Spacing= 18.00 in Htrrhk Ratio=
0.353 Max Horiz. Spacing = 16.30 in Eccentric Dead Load =
18.6 psf Beta1 = 0.85 Eccentric Live Load =
0.75 in 0.6 x Rhow Balance = 0.0128 Load Eccentricity =
Additional lmaosed Loads:
9 ft Shall LL be used with laterial load combination? Y=l,N=O--> -,.
18 in Axial Unform DL= 3375 plf Point Lateral Load =
6 Axial Uniform LL= 0 plf X-dist. to Bottom =
6 n o.c.Unform Lateral Load = 99.28 plf Seismic=l. Wind=%>
Depth to steel= 15.25 in X-dist. to Bottom = 12 n
Rebar @ Reveal= 6 O.C. X-dist. to top = 23 R
d @Reveal= 15.25 in Seismic=l, Wind=2--> 1
Steel @ ea. face= 2 (1 for single layer, 2 for double layers)
..... ...... ~~.
...
....... 20 n
23 n
13.3
224 plf
280 plf
11 in
0
79.42 #
14.5 n
1
DESIGN SUMMARY;
LATERAL LOADINGS (U=1.32D + 0.55L + 1.1EN for seismic load combination.
. ~~~ ~~
U=0.75(1.4D+1.7L+1.7W) for Wind Load Combination.
Wallwt. = 225.0 psf Wind Loadx 1.275= 23.7
Seismic Service= 79.4 psf Factored Seismic = 87.4
~~ ~ ~~~ ~~
.... .. ... ..iiiiii
VERTICAL
Loading
P axial = 224
P wall = 5,873
PIA= 28.20
Pu-Axial= 296
Pu-Wall= 7,752
Pu-Total= 8,047
ANALYSIS:
As(eff)=[Pu:tot + (As'Fy)YFy =
' a'=(As*Fy+Pu)l(O.85rd12) =
1110 c=alBeta=
Phlz0.9 - 2'PU/(fC*Ag)=
Mn=As(eff)'fy.(d-a/Z)=
Mu= Phi'Mn=
E=57000'(l~)~0.5=
n=29000/Ec=
F1=5'(fc)"0.5=
Gross section modulus=
Mcr (cracked Moment Cap.)=
I gross =
I uacked =
VERTICAL
@Reveal Loading
224 224
6,525 6075
32.60 29.20
296
8,613
8,909 -
AUw&
1.014 N.A
I .988 N.A
2.339 N.A
,0.88 N.A
752,704 N.A
658,738 N.A
3.1€+06 N.A
9.29 N.A
273.9 N.A
648.0 N.A
177,462 N.A
5832.0 N.A
1628.0 N.A
235
6379
6614
@Reveal
224 plf
6525 plf -
32.60 psi O.O4*fc= 120.00 psi
235 plf
6851 plf
7086 plf
0.990
I .942
2.284
0.68
753,941
663,156
3. I E+06
9.29
273.9
646.0
177,462
5832.0
1600.0
AUw&
N.A
N.A
N.A
N.A
(108,068)
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
in"M
in
in
in#
in#
psi
Psi
inA3
in#
inA4
inA4
"
........................................
RETAINING WALL DES16ti """""""""_""""
) DESCRIPTION :RETAINING WALL AT NEW PROPOSED TRUCK WELL
> DESIGN DATA
Soil Bearing Press = 1,000 psf FOOTING :
Passive Pressure = 150 ptf f'c - Concrete
Active Fluid Press = 35 ptf FtglSoil Friction = 0.35
= 2,500 psi
Soil Density = 110 pcf Fy - Reinforcement = 60,000 psi
> WALL LOADING CONDITIONS """""""""""-
Slope of Backfill = 0 :I Design Fluid Prwure 35.0 ptf
(horiz:vert,O=Level) (Corrected for Slope)
Surcharge over Toe = 0 psf Surcharge over Heel = 70 psf
Shall Surcharge be used in Resisting Koment? Y.1, N=O --> 0 <--
Soil Ht over Toe = 10 in Axial Load on SteR = 0 plf
Wall Kt above Soil = 0.5 ft Load e Uall Above Soil= 0 psf
ADJACENT FOOTING LOAD : Uidth of Footing = 0 It
Footing Load = 0 plf Ftg. Dist. frot Wall = 0 ft
Spread Footing ? Depth of Bearing Belou
Yz1 , NzO : --> 0 Soil @ Rear F.O.U. = 0 ft
UNIFORA LOAD (Added); 0 plf Bottom Above T.O.F. = 0.00 it
WALL tr FOOTING SEOtlETRY
Top Above T.O.F. 0.00 ft
> RETAINED HEIGHT = 4.833 It > Footing Thickness = 12 in
6 in
Stea Uidth = 0.67 It > Toe I Key Dist.
8 in
= 1.33 ft
"""""""""""-
(above T.O.F.) -
> Toe Hidth
> Key Depth
= 2 It > Key Uidth
> Heel Width = I?,?? !t
-
I SOIL PRESSURE @ TOE.
I SOIL PRESSURE @ HEEL
I FACTOR OF SAFETY : Sliding = I FACTOR OF SAFETY : Overturning =
I ONE-HAY SHEAR AT TOE SIDE OF STEM
I ONE-HAY SHEAR AT HEEL SIDE OF STEH
- - - 965 psf : 1,000 = Allou I
149 psf
2.21 ) 1.5, --> OK
1.46 > 1.5, --> OK
=( 1 ) OK
=( 1 > OK
"__""""""""""""""""""""""""""""""""""""""
STABILITY CHECK
) NOTE: Should 113 of Active Pressure be used as Vertical _"
Pressure at rear face of stee? Y=1 , H = 0 ---)> 1 "_
OVERTURNING MMENT = 1,537 ft-i
RESISTING HOHENT = 3,392 ft-# NAX. LATERAL FORCE ~725.33 #
FACTOR Of SAFETY : Overturning --) 2.21
SLIDING CHECK
Hax. Lateral Force = 725 # > Ht. of Soi! to Neglect = 0.00 in
Hax. Resis. Force = 1,057 # Passive Pressure = 469 t
F.S. : S!iding = 1.46 Friction Pressure = 588 #
SOIL PRESSURE
Eccentricity froe CL = 0.36 ft Kern Distance = 0.49 ft
UN-FACTORED FACTORED """""_ - "_ _" -
) SOIL PRESSURE C TOE = 965 psf 1,641 psf
> SOIL PRESSURE @ HEEL = !49 psf 0 psf
TOE DESIGN
Ku"= Upvard = 2435.58 ft-1 HU : DESIGN I?OIIENT = 1772.9 ft-l
Nul = Dounurrd = 662.656 ft-#
Rebar Cover
) Z Steel fiininur = 0.0012
3 in
d lht-Cover 9.00 in
As : Required 9.044 in*Z/ft =
As : Provided 0.130 inA21ft X-u
= 25.24
= 24.3 psi
- -
One Way Shear: Try: t4 @ 18.5 t7 @ 55.5 '
Fv = 2*(f'c".5) = 100.00 psi 15 @ 28.5 * t8 @ 73.5 '
Actual Shear I Phi= 11.17 psi 16 @ 40.5 ' P9 @ 92.5 '
HEEL DESIEN
) Neglect Upward Soil Pressure? Y=l,N=O --) 1
"""""_ "_
"_
Mut1= Downward = 60.8330 ft-# nu : DESIGN MOMENT 60.833 ft-#
Mu, = Upward = . 0 ft-$
Rebar Cover
) X Steel Mininul = 0.0012 d = Tht-Cover = 9.00 in
= 0.8 psi
- 3
As : Required = 0.002.inA2/ft '1' =
As : Provided = 0.130 inA2/ft R-u
= 28.24
One Uay Shear: Try: 14 @ 18.50 ' X7 E 53.50 '
fv = 2i(f'cA.51 = 100.00 p5i 15 @ 28.50 ' 18 @ 73.50 '
Actual Shear I Phi= 0.00 psi $6 @ 40.50 ' 1.9 @ 92.50 '
........................................
TOP STEH SECTION DESIGN """""""""""- "_
) WALL MATERIAL : CONCRETE = 1, KASONRY = 2 : --)f 2 <<-- "_ > f'a Masonry
f Fs : for liasonry = 24,000 psi Loaded Section Height = 5-33 tt
= 1,500 psi ) Eottos Ht. above IOF = 0 ft
> fy : for Concrete = 60,000 psi Total Lateral Pres;. = 516.40 I
) ffc Concrete = 3,000 psi
f Load factor = 1.00 Mariaurn Hs:Service 918.63 ft-1
) 6routing? Y=l H=O f 1
f Inspected ? V=1 N=O> 0 f UALL THICKNESS
f Center.1 , Edge.2 -) 2
Masonry : Actual Allow. REQ'U SPACING = 32.09 in
fa = 20,400 24,000 psi 'dl for design
Eond Length Req'd = 31.9 in Allowable Unit Shear = 25.0 psi
= 5.25 in
Actual Unit Shear = 5.7 psi
- - 8 in
f REBAR SIZE # 5
f',q E 236 250 psi Rebar kea Supplied = 0.12 in?
I-
I
- !
". .
... .
~ ..... . .. ..... - ~
.~
OF STRUCULBES.
(SEC. 1632 OF 1997 U.B.C.)
Fp= ap Ca IP (1+3'hxlhr)Wp
RP
hl= 19.50 R Seismic source type = 2
h2= 9.50 R (A=l , B=2. C=3)
ap= 1.00
Ip= 1.00 -~
Rp= 3.00
Closest distance = 5 km
Soil Profile Type =
Near Source Factor Na=
Ca =
Fp =
Fp =
Fp =
Fp =
Total Seismic Load=
Roof Reaction =
Base Reaction =
4
1 .o
0.44
0.15
0.587
0.308
0.801
14.54
13.04
1.50
(SA=l, SB=2,SC=3,SD=4,SE=5)
(When soil properties not known, use Type SD
per section 1629.3. Exception)
(if Na 4.1, check w/ section 1629.4.2 for special condition)
'(1+3*hxlhr)Wp 0.7'Caglp= 0.308
4'Ca'lp= 1.76
'Wp athx=hr
Wp for hx=O to hx= 7.02 R
* Wp at top of wall
WP
* WP - WP
Where Wpweight of wall psf
Maximum Moment = 3.79 * Wp-R
Maximum Moment occurs = 4.88 R from base
.. PrnW
weq= 8'Max.
hrA2
for Wall Design
Force at roof= l624Q ap= 1.5
PRECAST CONCRETE WALL DESIGN
Considering P-Delta Effects
SEAOC "Green Book" To iterate P-Delta effects to convergence
using 1997 UBC Load factors.
DESCRIPTION: CHECK EXIST. PIER A
DFSlGN DATA:
ACUSHNET 1812 Ashton
PC= 3,000 psi Min. Vert. Steel % = 0.0025 Clear Wall Ht =
Fy= 80,000 psi Min. Horiz. Steel % = 0.0015 Total wall Ht =
Phi= 0.87 Max Vet. Spacing= 18.00 in HVThk Ratio=
Seismic Factor= 0.308 Max Horiz. Spacing = 18.00 in Eccentric Dead Load =
Wind Load= 18.6 psf Beta1 = 0.85 Eccentric Live Load =
Reveal Depth= 0.75 in 0.8 x Rhow Balance = 0,0128 Load Eccentricity =
Reveal to Bot= 9 R Shall LL be used with laterial load combination? Y=l,N=O--S-
Add/bona/ / maosed Loads: ..
Wall Thk.= 7.5 in Axial Unform DL= 1156 plf Point Lateral Load =
Rebar Size # = 5 Axial Uniform LL= 246.4 plf X-dist. to Bottom =
Rebar Spacing= 10 in o.c.Unform Lateral Load = 16.94 plf Seismic=l, Wind=2-->
Depth to steel= 4.94 in X-dist. to Bottom = IO n
Rebar @ Reveal= 10 in O.C. X-dist. to top = 29 ft
d @ Reveal= 4.94 in Seismic=l, Wind=2-> 1
Steel @ ea. face= 2 (1 for single layer, 2 for double layers)
DESIGN SUMMARY:
19.5 ft
29 fl
31.2
154 plf
280 plf
7.5 in
0
87.4 #
16 ft
1
LATERAL LOADINGS W1.32D + 0.55L + 1.IE)) for seismic load combination.
U=0.75(1.4D+1.7L+l.N\I)forWind Load Combination.
Wall wt. = 93.8 psf Wind Loadx 1.275= 23.7
Seismic Service= 28.9 psf Factored Seismic = 31.8
PRECAST CONCRETE WALL DESIGN
Considering P-Delta Effects
SEAOC "Green Book" To iterate P-Delta effects to convergence
using 1997 UBC Load factors.
DESCRIPTION: CHECK EXIST. PIER A
ACUSHNET 1812 Ashton
VERTICAL
Loading
P axial = 154
P wall = 3,107
PIA= 36.20
Pu-Axial= 203
Pu-Wall= 4,101
Pu-Total= 4,304
As(eff)=[Pu:tot + (As*Fy)YFy =
' a'=(As*Fy+Pu)/(0.85'fc*l2) =
I*, I c=a/Beta=
Phi =0.9 - Z*Pu/(fc*Ag)=
Mn=As(ev.fyqd-a/Z)=
Mu= Phi'Mn=
E=570M)'(fc)"0.5=
n=29000/Ec=
Fr=5'(fc)"O.5=
Gross section modulus=
Mu (cracked Moment Cap.)=
I gross =
I cracked =
VERTICAL
@Reveal Loading @Reveal
154
3,031
39.30
203
4,001
4,204 -
At Reveal
0.444 N.A
0.870 N.A
1.024 N.A
0.87 N.A
100,551 N.A
87,290 N.A
3.1 E+06 N.A
9.29 N.A
273.9 N.A
112.5 N.A
30.809 N.A
421.9 N.A
67.5 N.A
154 154 plf
3107 3031 plf -
36.20 39.30 psi 0.04'fc= 120.00 psi
162 162 plf
3262 3183 plf
3424 3344 Dlf
0.429
0.841
0.990
0.87
100,872
88.226
3.1E+06
9.29
273.9
112.5
30,809
421.9
66.1
-1
N.A
N.A
N.A
N.A
(16,521)
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A
inWR
in
in
in#
in#
psi
psi
in"3
in#
inA4
inA4
PRECAST CONCRETE WALL DESIGN
Considering P-Delta Effects
SEAOC "Green Book' To iterate P-Delta effects to convergence
using 1997 UBC Load factors.
DESCRIPTION: CHECK EXIST. PIER B
DFslGN DATA:
ACUSHNET 1812Ashton
fc= 3,000 psi Min. Vert. Steel% = 0.0025 Clear Wall Ht =
Fy= 60,000 psi Min. Horiz. Steel % = 0.0015 Total wall Ht =
Phi=
Seismic Factor=
Nnd Load=
Reveal Depth=
Reveal to Bot=
Wall Thk.=
Rebar Size # =
Rebar Spacing=
Depth to steel=
Rebar @ Reveal=
d @ Reveal=
Steel @ ea. face=
0.87 Max Vet. Spacing= 18.00 in Htrrhk Ratio=
0.308 Max Horiz. Spacing = 18.00 in Eccentric Dead Load =
18.6 psf Beta1 = 0.85 Eccentric Live Load =
0.75 in 0.6 x Rhow Balance = 0.0128 Load Eccentricity =
9 fl Shall LL be used with laterial load combination?Y=l,N=O-F
Additional lmoosed I oads;
7.5 in Axial Unform DL= 1266.5 plf Point Lateral Load =
5 Axial Uniform LL= 270 plf X-dist. to Bottom =
19.5 ft
29 ft
31.2
154 plf
280 plf
7.5 in
0
191 #
16 ft
10 in o.c.Unform Lateral Load = 18.57 plf Seismic=l. Nnd=2-> 1
4.94 in X-dist. to Bottom = 10 fl
10 in O.C. X-dist. to top = 29 ft
4.94 in Seismic=l. Wind=%" 1
2 (1 for single layer, 2 for double layers)
LATERAL LOADINGS (U=1.32D + 0.55L + 1.lEN for seismic load combination.
U=O.75(1.4D+1.7L+1.7W) for Nnd Load Combination.
Wall wt. = 93.8 psf Wind Loadx 1.275= 23.7
Seismic Setvice= 28.9 psf Factored Seismic = 31.8
PRECAST CONCRETE WALL DESIGN
Considering P-Delta Effects
SEAOC "Green Bwk" To iterate P-Delta effects to convergence
using 1997 UBC Load factors.
DESCRIPTION: CHECK EXIST. PIER B
ACUSHNET 1812 Ashton
VERTICAL
Loading
P axial = 154
P watt'= 3,163
PIA= 36.90
Pu-Axial= . 203
Pu-Wall= 4,175
Pu-Total= 4.378
As(eff)=[Pu:tot + (As'Fy)]/Fy =
' a'=(As*Fy+Pu)/(O.65*fc*l2) =
I, I, c= a /Beta =
Phi =0.9 - 2*Pu/(fc*Ag)=
Mn=As(evy(d-aD)=
Mu= Phi'Mn=
E=57000'(fc)"0.5=
n=29000/Ec=
Fr=5*(fc)"0.5=
Gross section modulus=
Mcr (cracked Moment Cap.)=
I gross =
I cracked =
VERTICAL
@Reveal Loading @Reveal
154
3.142
40.70
203
4,147
4.350 -
At Reveal
0.445 N.A
0.872 N.A
1.026 N.A
0.87 N.A
100,524 , N.A
67,212 N.A
3.1E+06 N.A
9.29 N.A
273.9 N.A
112.5 N.A
30.809 N.A
421.9 N.A
67.6 N.A
154 154 plf
3217 3142 plf -.
37.50 40.70 psi O.O4'fc= 120.00 psi
162 182 plf
3378 3299 plf
3540 3460 plf
0.431
0.845
0.994
0.87
100,630
88.103
3.1E+06
9.29
273.9
112.5
30,809
421.9
66.3
A.t&Y%d
N.A
N.A
N.A
N.A
(17.094)
N.A
N.A
N.A
N.A
N.A
N.A
N.A
N.A .
inWR
in
in
in#
in#
psi
psi
in"3
in#
inA4
in"4
538 CHECK EXIST. PURLlN """""""""- 99-340
s0809/30/99 ENGlNEERS SHT :
slp12vlsOb4148TBEAH ANALYSIS PR06RAHslp9vlaOb4148T ~6.60~~0p10.00h12vOsOb31
SPAN LENGTH = 27.50 It
(Silple Span)
UNlFORll LOADS Wft & ft)
ud
0.Ofifi 0.128
ul
0.C0 27.50
X1 - 12
0.178 0.000 5.00 8.00
REACTIONS (k)
LOAD
Dead
LEFT RIGHT
1.618 1.336
Total
Live 1.760 1.760
3.378 3.096
tlAXI8Ufl FORCES
V @ax = 3.38 k @ 0.00 ft
H rax = 22.19 kft @ 13.17 It
DEFLECTIONS (El kinA2)
LOAD
Total
Defl (in) X fft)
3041115/EI 13.61
Live 164711WEI 13.75
Dead 13936411EI midspan
Brace Spacing = 1.00 ft
Pos. Homent Lu = 1-00 It
ReQUired El = 1658790 tin*2
60v. Deflection : Total = LIMO
538
6LB 2.5 X 16.5 24F-V4~0B
Design per 1991 NDS
Douglas Fir-Larch
STRESSES (psi 1
Shear @ 'dl :
Fv = 206 fv = 112 54 X
fb' = 2956 fb = 2347 79 2
V = 3.08 k @ 1.38 ft
Live LDF = 1.25, Cv = 1.00, C1 z 0.99
DEFLECTIONS (in) (E = 1800 ksi)
Live = 0.98 = L I 337 71 1
Total = 1.81 = L I 183 98 I
Dead = 0.83
SINGLE SHEAR CONNECTION PERP. TO GRAIN K/ A36 SIDE PLATES """""""""""""-
(per sect. 8.2.2 Of 1991 NDS)
BOLT DIANETER
Fyb (ksi) =
0.75
45
LOAD FACTOR = 1.25
ta (in) = 6.75 depth = 31.5 inch Fes = 58000 psi
ts (in) = 0.375 depth = 6 inch (Bearing Capacity)
fiAIN HENBER DOYEL BEARIN6 STRENGTH
feu PERPEND TO GRAIN = 2500 osi Ea = 1600 tsi
SIDE IENBER DOWEL BEARING STRENGTH AB = 212.625 sq.inch
Fes A36 Bearing Cap. = 58006 psi Es = 29000 ksi
Noainal Bolt Design Value
As 2.25 sq.inch
I = D€ta€Fea/(4Ko) = 2531.25
Z = DA2/(3.2tKo) €!2*fe~€Fyb/(3*(liRe)~~0.5= 1192.42
I = k3rD€ts€Fe1/(3.2(2tRe)€Ko) = 955.21
I = k2€D*ta€Fer/(3.2(1+Re)*Ko)
Z = kl*DitsfFes/(3.6€Ko)
= 1507.29
=3152.346
2 ein = 955.21 Pound
TOTAL t BOLTS = 3 BOLTS (BOLTSIROUS) n = 3 ROU Of BOLTS =
BOLT SPACING = 1 ROUS Group Action Cg = 0.989
3 INCH
CONNECTION GOOD FOR = 3.54 KIPS
! A
N I
<-Roof
z
<-lst Flr
(SEC. 1632 OF 1997 U.B.C.)
Fp= ap Ca IP (1+3*hxlhr)Wp
hl=
h2=
ap=
Ip=
Rp=
Soil Profile Type =
Near Source Factor Na=
Ca =
Fp =
RP
16.00 n Seismic source type = 2
0.00 it (A=l, B=2, C=3)
2.50
1 .oo
3.00
Closest distance = 10 km
-.
3 (SA=l, SB=Z,SC=3,SD=4,SE=5)
(When soil properties not known, use Type SD
per section 1629.3. Exception)
1.0 (ii Na >1.1. check wlsection 1629,4.2 for special condition)
0.4
0.33 '(1+3*hxlhr)Wp 0.7*Ca'lp= 0.28
4'Ca'lp= 1.6
Fp = 1.333 * Wp at hx = hr
0.333 'Wpforhx=O to hx= #N/A it Fp =
Fp =
Total Seismic Load=
Roof Reaction =
Base Reaction =
Maximum Moment =
Maximum Moment occurs =
for Wall Design
1.333 Wp at top of wall
13.17 'Wp 7.92 'Wp 5.25 'Wp
26.64 - wpn
8.80 it from base
eaaam hr"?
Where Wp=weight of wall psf
w eq= 8' Max.
HR-36 18-24 Gauge Archltectural Panels
See Light Gauge Roof and Wd Panels section for26 1 29 gauge.
Featuring
'Itvice the Life! Reversed HR-36 CrLpieal Wall AppNutlon)
0 Excellent choice for industrial roof and
0 Symmetrical shape and strong shadow - 4 c
r (mated side)
wall applications.
effect makes for architecturallv oleasinn
- L-J
36" _. commercial applications. -
0 Longspan capability - economy in design.
0 Matching flashings and accessories
available.
I- S- I+ S+ wt Gauge
0 Available in wide variety of PVF, (Polyvinylidene Fluoride) colors,
Zincalumem, or G90 galvanized coated steel. 20 1.85
18 2.46
1907 2085
3264 2633 3055 2721
HR-36 SecHon Properlies
@bW
,1141 ,1156 ,1116 ,1234 120 24
(in'&) (in'h) (in'&) (inS&)
22
:1504
153
BHP Steel Building Products USA Inc.
HR-36
18 DS f 212 I47 108 83 66 53 44 37 Gauge vi80 212 147 108 83 66 53 42 33
TS f 248 172 126 97 76 62 51 43 vi80 248 172 126 92 €4 47 3.5 27
Noted: 0 Steel conforms to ASTM A446 Grade C or ASTM A792 Grade 40. 0 Valued rue based on the American Iron and Steel Institute (AISI) 'Specifications for the Dm/@ of Cold-Rolled Steel
0 For wind loadlng, multiply allowable load values by 133 or allowable span values by 1.15. 0 Spanbad combinations to the right of the bold line apply to walls only.
StructumlMembed(1986 edition.with 1989Addendum).
Loading Table Legend
f-had limited by flexural bending stress
LSW l/bcrhad limited by deflection
SS-Single span
DS-Double span
TS -Triple span
t,L,t support Typ
t,~,t,~,t
~,L-.?-L -.t,~--, t
,~ ' .
NEW 14'X 22' CANOPY "CENTER GIRDER
Magnltude
Mx (Max) 71.899 K-in
Locatlon
4.68 ft
Vx (Max) 1.283 KIPS 0.00 ft
I Required 15.6921 inA4 7.00 ft
-Pan I Length (n) I Load (PLt-) 1 Moment (K-In) 1 Locatlon (ft) I Defl. t-act. (in) 1 Locatlo" (n) 11 14.00 I 0.0 I 11.899 I 4.68 1 7.00
SUPPOfi LOC. Reaction Moment LOC. Pt Load
(ft) (K-in) (W (ft) (Ibs)
Mag. (K-in) Moment
1
71.899 1283.0 9.33 2 1283.000 0.000 14.00 2
71.899- "-74.67-1283.0 0.000 0.00
i
NEW 14'X 22' CANOPY "CENTER GIRDER
Member: C8-2-14 Manufacturer: Generic Yield = 50.0 KSI Configuration: Boxed
Dimensions
Depth - 8.0000
Flange = 2.0000
Lip - 0.5625
Bend = 0.1065
t - 0.0710
Punch . = 1.5000
Wlip = 0.3850
Web = 1.6450 7.6450
-
-
-
wflg =
- In
in in
in in
in
in
in
in
Gross Properties
Area 1.i9
Ix = 16.02 - 4.99
Rx - 2.99
cw
- 1.67 - 0.00
JxlOE3 = 0.00 x0
Ro
- 0.00 - 0.00
Beta = 0.00
- -
lY
RY
- - - -
- -
"-
in4
in4
in
in
in6
in4
in
in
Loads and Bracing
Axlal:
P=
KXLX = 56.00 in
6.74 KIPS
KyLy =
KtLt = 56.00 in 56.00 in
Bending:
Mx = 71.90 K-in
KLx =
KLy = 56.08 in
KLt = 56.00 in
56.00 in
AXIAL ANALYSIS
Eq. C4.1-1 Fex, = PiA2E/(KWRx)"2 = 831.27 KSI
Eq. C4.1-1 Fey = PiA2W(KLy/Ry)Y = 259.24 KSI
Fe = 259.24 KSI
Fe > Fy/2. Therefore Fn = Fy(1 - Fy/4Fe), Fn = 47.59 KSI
Find Ae at stress Fn:
Eq. C4-1 Pa = Pn11.92 = 23.30 KIPS
Eq. C4-2 Pn = AeFn = 44.75 KIPS
eFlange = 1.645 in; eLip = 0.205 in; eWeb = 2.030 in; Ae = 0,940 in
With 1/3 stress increase Pa = 31.07 KIPS
BENDING ANALYSIS
Find effective section at stress Fv = 50.00 KSI
Eq. C3.1.1-1 Mn = SeFy = 200.20 K-in
Eq. C3.1-I Ma = Mn11.67 = 114.83 K-in With 113 stress increase Ma = 153.1 1 K-in
eLip = 0.179 in; eWeb 6.145 in; ~ Sc = 3.835 inA3'
COMBINED AXIAL AND BENDING
Eq. C5-4 Omegax = 1 - 1.92PIPcr = 0.991
Eq. C5-5 Pcr = PiA2Elx/LxA2 = 1486.92 KIPS
With 1/3 stress increase = 0.993
With 1/3 stress increase = 1982.57 KIPS
Interaction Equations:
Eq. C5-1 PlPa + Mx/MaOmegax = 0.921
Eq. C5-2 P/Pao + Mx/Ma = 0.901
With 1/3 stress increase = 0.689
With 113 stress increase = 0.676
SHEAR ANALYSIS
hlt > 1.38'(5.34*E/Fy)A.5. ThereforeVa= .53'E'5.34'tA3/h
Va = 7.82 KIPS With 1/3 stress increase = 10.42 KIPS
NEW 14'X 22' CANOPY "CENTER GIRDER STRuCMzAL 0x2
Web Crippling Analysis
Member: C8-2-14 Manufacturer: Generic Yield = 50.0 KSI Configuration: Boxed
Web Crippling Equations
C 3.4 -1: Pa = t2kC3C4 (179 - 0.33hlt) [I + O.Ol(N/t)]
C 3.4 4: Pa = t2kC1C2 (291 - 0.40hlt) [I + 0.007(N/t)]
Where:
When N/t > 60, the factor [I + O.O07(N/t)] may be increased to [0.75 + O.ll(N/t)]
Pa =Allowable concentrated load or reaction per web, Ibs
C1 = (1.22 - 0.22k) 0.887
C2 = (1.06 - 0.06Wt) <= 1 0.970
C3 = (1..33 - 0.33k) 0.830
C4 = 0.50 (1.15 - 0.15Wt) <= 1 0.925
Fy = Design yield stress of thsweb 50 KSI
h = Depth of flat portion of web 7.645 inches
k=Fy/33 \ 1.515
m=t/0.075 0.947
t = Web thickness 0.0710 inches
R = Inside bend radius 0,1065 inches
N = Bearing width, inches
Ma =Allowable bending moment 114.8313 K-in
Combined bending and web crippling: 1.2 /PI Pal + IM / Mal <= 1.5 (Eq. C3.5 -1)
NEW 14' X 22' CANOPY 11' JOISTS @ 4'-8 0.c.
Overall Length of Beam: 11 R Axial Load: ,341 KIPS Deflection Limit: 360.0
I 111 I
Magnltuae
Mx (Max) 21.236 K-in
Locatlon
5.50 ft
Vx (Max) 0.643 KIPS 0.00 ft
I Required 3.5632 1nA4 5.50 R
Span I Length (ft) 1 Load (PLk)/ Moment (K-in) 1 Locatlon (ft) 1 Dm. Fact. (In) I Locatton (it) 11 11.00 I 11 1.0 I 21.236 1 5.50 I - 65 1 5.50
Support I Location (ft) 1 Moment (K-In) 1 Reaction (Ibs) 1 I 0.00 I 0.000 1 643.5
121 11.00 I 0.000 I 643.500 I
NEW 14' X 22' CANOPY 11' JOISTS @ 4'-8 O.C.
Web Crippling Analysis
Member: C8-158-16 Manufacturer: Generic Yield = 50.0 KSI' Configuration: Single
Web Crippling Equations
C 3.4 -1: Pa = t2kC3C4 (179 - 0.33hIt) 11 + O.Ol(N/t)]
Where:
Pa = Allowable concentrated load or reaction Der web. Ibs
C3 = (1..33 - 0.33k)
C4 = 0.50 (1.15 -0.15FUt) <= 1
Fy = Design yield stress of the web
h = Depth of flat portion of web
k=Fy133
m = t 10.075
t = Web thickness
R = Inside bend radius
N = Bearing width, inches
Ma =Allowable bending moment
Combined bending and web crippling:
0.830
0.925
50 KSI
7.71 7 inches
1.515
0.755
0.0566 inches
0.0849 inches
41.8662 K-in
1.2 IP I Pal + IM I Mal <= 1.5 (Eq. C3.5 -1)
..
. . .,. ., .
NEW 14' X 22' CANOPY JOIST UPLIFT CHECK
Overall Length of Beam: 11 R Axial Load: 0 KIPS Deflection Limit 360.0
56.6 1
Mx (Max) 10.273 K-in 5.50 ft
Vx (Max) 0.311 KIPS 0.00 fl
I Required 1.7238 in"4 5.50 ft
LOaa (PLF) j Moment (&In) I Location (it) I Defl. Fact. (in) 1 Locatlon (ft)
56.6 j 102 I3 I 5.50 I CEZO 5.50
Support I Location (ft) I Moment (K-in) I Reactlon (Ibs)
1 I 0.00 1 0.000 1 31 1.300
I21 11.00 I 0.000 I 311.300 I
c 44 "
ACUSHNET: 1812 Aston Avenue, Carlsbad CA 3dI
UNIFORMlCALIFORNIA CODES ANALYSIS
,, ,, ,*:I:%: , ', ., ., ,,
,,
TECHNICAL , ,.. REPORT
WAREHOUSE , ,, OPERATIONS ,,
,, ,, .,
. , ,, . , .. ,,
25 October 1999
Prepared by
AEriksen-Rattan Associates Inc.
8989 Rio San Diego Drive - Suite 200
San Diego, California 92108-2048
Telephone 619.2996444
FAX619.299.1229
EMAIL era@eciti.com
This report is the property of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by Acushnet for the operations 8
conditions described in this report. Copies of this report retained by Acushnet shall be utilized only by Acushnet for occupancy
This report shall not be used for the purpose of construction for this project or any other project or for any other purpose.
classification and the 1997 Uniform Coded1998 California Codes conditions 8 requirements addressed in this report.
- ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNlFORMlCALlFORNlA CODES ANALYSIS
OVERVIEW - TECHNICAL REPORT
WAREHOUSE OPERATIONS
Eriksen-Rattan Associates Inc. prepared this "Technical Report" for the exclusive use of Acushnet. The
report addresses 1997 Uniform/l998 California Code requirements and conditions applicable to Acushnet
warehouse storage operations located in an existing 2-story, fully sprinklered, single tenant building at
1812 Aston Avenue in Carlsbad. California.
Warehouse storage operations will involve rack storage of Class I-IV Commodities to </=15' above the
finished floor [high-piled combustible storage]. The only "hazardous materials" conditions in the
warehouse will be LPG powered industrial trucks/forklifts, with an aggregate/total LPG amount of <30
gallons [less than the Exempt Amount of flammable gases].
Existing conditions in the warehouse area of the building appear to be in reasonable compliance with
applicable Code requirements for the storage conditions described above, except for perhaps the
following conditions
Automatic 8. Manual Opening SmokelHeat Vents
0 Draft Curtains
Class II Standpipe System [Small Hose Lines]
The above Code requirements would not have to be applied if the storage height of Class I-IV
Commodities was reduced to </=12'
Conditions other than the conditions addressed or described herein are outside the scope of this report.
Discrepancies between the information presented herein and actual conditions and conditions presented
on plans are the sole responsibility of Acushnet. Verification of compliance with the Code requirements
and provisions addressed herein is outside the scope of this report. Tenant improvement plans and
construction documents will be provided separately through Smith Consulting Architects.
ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNlFORMlCALlFORNlA CODES ANALYSIS
INFORMATION - TECHNICAL REPORT
WAREHOUSE OPERATIONS
Questions concerning Acushnet operations should be directed through:
Luis Cardenas - Facilities Manager
1021 West Mission Avenue
Escondido, California 92025
Telephone 760.737.3834
FAX 760.737.3805
Questions concerning plans and construction documents for this project should be directed to:
12220 El Camino Real - Suite 200
San Diego, California 92130
Telephone: 619.793.4777
Questions concerning this report should be directed to:
Mary Eriksen-Rattan
San Diego. California 92108-2048
8989 Rio San Diego Drive - Suite 200
Teleohone 619.299.6444
FAX'619.299.1229
EMAIL erai@eciti.com
Discrepancies between the information presented herein and actual conditions and conditions presented
on plans are the sole responsibility of Acushnet. Verification of compliance with the Code requirements
and provisions addressed herein is outside the scope of this report.
... 111
ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNlFORMlCALlFORNlA CODES ANALYSIS
TABLE OF CONTENTS - TECHNICAL REPORT
HAZARDOUS MATERIALS & STORAGE OPERATIONS
iv
ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNlFORMlCALlFORNlA CODES ANALYSIS
1. Existing Building Conditions
Features
2. Occupancy 8 Control Area Conditions
Acushnet Conditions
+Construction: Ill-N
+Stories: 2
+Area:
TotaVAggregate: 64,653 sf * A3: 1,155 sf
* F1: 41,478 sf * 61: 11,677sf
* A3: 1,155 sf * 8: 11,677 sf * FI: 41,478 sf
* B: 10,343 sf
1st Floor: 54,310 sf
. 2nd Floor: 10,343 sf
+Sideyards: >/=60' on all sides
+Fire Extinguishing System: Fire sprinkler system.
Designed for 0.33 gpm over 3,000 sf.
UseslOccupancy Conditions:
+Operations:
* s1: - Warehouse storage. . Class I-IV Commodities: . 4=15' Rack Storage - Golf Clubs - Golf Balls - Golf Bags . Paper 8 Cardboard Goods [Boxes. Marketing
* 8:
Materials, Offtce Supplies] . Sales, marketing, customer service, offices 8 - Employee 8 public areas. * A3: Employee Lunchroom. +Building Control Areas: One [I] +Hazardous Materials Inventory:
administrative/support operations.
LPG in forkliftslpowered industrial trucks.
LPG Information: * CAS #: 74-98-6 * Hazard Classification: Flammable Gas
* Exempt Amount - No Cabinets: 30 gallons * Acushnet Amount: e30 gallons
Code Requirements & Provisions - 10/25/99 - Page 2 of 12
Technical Repolt -Warehouse Operations
ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNlFORMlCALlFORNlA CODES ANALYSIS
2.0 WAREHOUSE OPERATIONS
The following table provides an overview of th
Operations
1. Storage Commodities
2. Storage Conditions
3. ForkiftslPowered
Industrial Trucks
e warehouse storage operations and conditions,
Conditions
+Class I-IV
Golf Clubs
Golf Balls
Golf Bags
Paper & Cardboard Goods [Boxes, Marketing Materials, Office Supplies]
Packaging Materials
(Class I-IV Commodities:
Storage Type: * Racks * Single & Double Row
Storage Heights: cl=15' to top of storage Encapsulated: No
Palletized: Yes - slatted bottom pallets
High-Piled Combustible Storage: Yes
Main Aisles: 8.5'
Cross Aisles: >44"
Dead-Ends: None
Open -wire mesh shelving.
,Aisles:
)Shelving:
)Distance Between Top of Storage 8 Sprinkler Deflectors: >/=18".
)Type:
LPG powered.
e30 gallons aggregate LPG )Conditions:
Used 8 parked inside warehouse.
AErikren-Ranan Associates Inc.
8989 Rio Sa" Diego DrivelSuile 200 - Sao Diego CA 92108 Code Requirements 8 Provisions - 10/25/99 - Page 3 of 12
Technical Report - Warehouse Operations
ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNlFORMlCALlFORNlA CODES ANALYSIS
TECHNICAL REPORT
WAREHOUSE OPERATIONS
CODE REQUIREMENTS & PROVISIONS
1.0 SCOPE
Eriksen-Rattan Associates Inc. prepared this "Technical Report" for the exclusive use of Acushnet. The
report addresses 7997 Uniform/7998 California Code requirements and conditions applicable to Acushnet
warehouse storage operations located in an existing 2-story. fully sprinklered, single tenant building at
1812 Aston Avenue in Carlsbad. California.
The facility will be used for warehouse storage of finished goods, marketing materials, packaging
materials and omce supplies; sales and marketing; customer service and ancillary office, administrative,
facility and site support operations. An overview of the Acushnet warehouse operations and the existing
building conditions addressed in this report is provided in Table 1.0 on page 2.
The report is organized as follows:
Section 2.0 - Acushnet Warehouse Operations: Discussion of Acushnet warehouse operations
0 Section 3.0 -Code Conditions (L Requirements: Discussion of Code conditions and
requirements and Acushnet warehouse conditions.
Building plans and construction documents will be provided separately through others. Review of plans
and documents for the conditions and requirements addressed herein is outside the scope of this report.
This report is the property of Eriksen-Rattan Associates Inc. and was prepared exclusively for use by Acushnet for the operations 8
conditions described in this report. Copies of this report retained by Acushnet shall be utilized only by Acushnet for occupancy
This report shall not be used for the purpose of construction for this project or any other project or for any other purpose.
classification and the 1997 Uniform Coded1998 California Codes conditions & requirements addressed in this report.
+-Ranan Asso~iales Inc Technical Report - Warehouse Operations
8989 Rio San Diega DrivveiSuite 200 - San Olego CA 92108 Code Requirements & Provisions - 10/25/99 -Page 1 of 12
ACUSHNET: 1812 Aston Avenue, Carlsbad CA
UNIFORMlCALIFORNIA CODES ANALYSIS
3.0 CODE ANALYSIS
The Code analysis that follows on pages 4-12 [Table 3.01 addresses the following applicable 1997
Uniform/l998 California Building Code and 1997/1998 Uniform/California Fire Code conditions and
reouirernents for Acushnet warehouse oDerations:
Occupancy Conditions
Location 8 Allowable Building Area
Occupancy 8 Control Area Separations
Storage Conditions
Draft Curtains
Smoke & Heat Venting
Separation of Incompatible Materials & Conditions
GeneraVArea Ventilation System
Class II Standpipe System
Portable Fire Extinguishers
Fire Extinguishing System
Water Supply
Fire Department Access
Premises Identification
Special Use Fire Department Permits 8 Plans
Operations and conditions not specifically related to the warehouse operations and Code conditions and
requirements other than indicated above are outside the scope of this report.
Conditions other than the conditions addressed or described herein are outside the scope of this report.
Discrepancies between the information presented herein and actual conditions and conditions presented
on plans are the sole responsibility of Acushnet. Verification of compliance with the Code requirements
and provisions addressed herein is outside the scope of this report.
Code Requirements 8 Provisions - 10/25/99 - Page 4 of 12