HomeMy WebLinkAbout1846 Marron Rd; ; CBC2018-0453; Permit(city of
Carlsbad
Commercial Permit
Print Date: 12/06/2018 Permit No: CSC2018-0453
Job Address:
Permit Type:
Parcel No:
Valuation:
Occupancy Group:
# Dwelling Units:
Bedrooms:
Project Title:
Description:
Applicant:
VERIZON WIRELESS
JIM VAN DALFSEN
1846 Marron Rd
BLDG-Commercial
1563011600
$122,135.26
Work Class:
Lot#:
Reference#;
Construction Type:
Bathrooms:
Orig. Plan Check#:
Plan Check#:
VERIZON: 2,626 SF T.I. (OFFICE TO OFFICE)
Owner:
PK I NORTH COUNTY PLAZA LP
Tenant Improvement
3333 New Hyde Park Rd Kimco Realty Corp,
100
BUILDING PERMIT FEE ($2000+)
BUILDING PLAN CHECK FEE (BLDG)
NEW HYDE PARK, NY 11042
ELECTRICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
MECHANICAL BLDG COMMERCIAL NEW/ADDITION/REMODEL
S81473 GREEN BUILDING STATE STANDARDS FEE
STRONG MOTION-COMMERCIAL
Total Fees: $1,386.21 Total Payments To Date: $1,386.21
Status:
Applied:
Issued:
Permit
Finaled:
Inspector:
Final
Inspection:
Contractor:
ICE BUILDERS INC
421 E Cerritos Ave
Anaheim, CA 92805-6320
714-491-1317
Balance Due:
Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter
collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these
fees/exactions. \f you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the
protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section
3.32.030. Failure to timely follow that procedure wlll bar any subsequent legal action to attack, review, set aside, void, or annul their
imposition.
You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection
fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this
project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the
statute of limitation has previously otherwise expired.
Closed -Finaled
08/08/2018
10/10/2018
MColl
12/6/2018 10:59:0lAM
$0.00
$707.65
$495.36
$89.DD
$55.DD
$5.00
$34.20
1635 Faraday Avenue, Carlsbad, CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov
THE FOLLOWING APPROVALS REQUIRED PRIOR TO PERMIT ISSUANCE: •PLANNING •ENGINEERING
(city of
Carlsbad
JOB ADDRESS
Building Permit Application
1635 Faraday Ave., Carlsbad, CA 92008
Ph: 760-602-2719 Fax: 760-602-8558
email: building@carlsbadca.gov
www.carlsbadca.gov
SUITE#/SPACEt/UNIT#
180
•BUILDING •FIRE •HEALTH 0HAZMATIAPCD
Plan Check No.
Est. Value
Plan Ck. Deposit
Date
APN
CT/PROJECT# LOT# PHASE# # OF UNITS # BEDROOMS #BATHROOMS TI=:NANT BUSINESS NAME CONSTR. TYPE OCC. GROUP
z.
DESCRIPTION OF WORK: Include Square Feet of Affected Area(s)
WMooe1.-J ~c?Tfl,t,ri.-r '"' e'{-1s•n,-..,1o ?,f>2-1p_ s i=-Wl~":.s (IQTPrlL. 1,11>U.
\Jllo~'t,. Wll-\, fit,lv'\frl2-1L-'{ A-\='Pe"<...T TH.i "Pll-orlT .?P-/tvLUt'1 ONl,>,f. (Jo Wo/4 wil,L
illr~ ()UA-1/4 tr-I 1l{f 1161'!-c.\'-,p tt1'1A.S€'.' Ot1rv,,.tl,t nor1 u; ,., wort -:;1fv,l\ur1All4rt.. WFrU-S.
EXISTING USE DECKS (SF) FIREPLACE
~~TPrlL ti Fr YESO,, N YES
PROPERTY OWNER NAME ~IMvO Rett-t.
ADDRESS JI, ZJ -S. ~1.,ie.0SE1 o V6
CITY ZIP CITY STATE ZIP 2-., s A CA '12-01' I
"J°l 6-'2o ~ I FAX
STATE Git-
FAX
GPA .lo
(Sec. 7031.5 Business and Professions Code: Any City or County which requires a permit to construct, alter, improve, demolish or repair any structure, prior to its issuance, also requires the applicant for such permit to file a signed statement tliat he is licensed pursuant to the provisions of the Contractor's License Law /Chapter 9, comme_nding with Section 7000 of Division 3 of the B_usiness and Professions Code} or that he is exempt therefrom, and the basis for the alleged exemption. Any violation of Section 7031.5 by any applicant for a permit subJects the applicant to a
civil penalty of not more than five hundred dollars {$500}).
WORKERS' COMPENSATION
Workers' Compensation Declaration: / hereby affirm under penalty of perjury one of the following declarations:
~ I have and will maintain a certificate of consent to sett-insure for workers' compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued.
1i2Y l have and will maintain workers' competatlon, as reQuired bv Section 370~ of the Labor Code, for the performance of the work for which this permit is issued. My workers' compensation insurance ca;ynd policy
number are Insurance Co Jo c Jt.. O(\ COr-\?o,C\I.C :!> PolicyNo.t:W'P '2 ~o,zs:r Expirat,onDa1,Jt?-I---
~section need not be completed if the permit is for one hundred dollars ($100) or less. LJ Certificate of Exemption: I certify that in the performance of the work for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of
California. WARNING: Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to crlmlnal penalties and civil fines up to one hundred thousand dollars (&100,000), in
addition to the cost of compensation, damages as rovided f in Section 706 of Labor code, interest and attorney's fees.
,IS CONTRACTOR SIGNATURE
I hereby affirm that I am exempt from Contractor's Ucense Law for the following reaS{)n: •
•
•
I, as owner of the property or my employees with wages as their sole compensation, will do the work and the structure is not intended or offered for sale (Sec. 7044, Business and Professions Code: The Contractor's
License Law does not apply to an owner of property who builds or improves thereon, and who does such work himself or through his own employees, provided that such improvements are not intended or offered for
sale. If, however, the building or improvement is sold 'Mthin one year of completion, the owner-builder will have the burden of proving that he did not build or improve for the purpose of sale).
I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec. 7044, Business and Professions Code: The Contractor's License Law does not apply to an owner of
property who builds or improves thereon, and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law).
I am exempt under Section ____ ,Business and Professions Code for this reason:
1. I personally plan to provide the major labor and materials for construction of the proposed property improvement. OYes ONo
2. I (have I have not) signed an application for a building permit for the proposed work
3. I have contracted with the following person (frrm) to provide the proposed construction (include name address I phone/ contractors' license number):
4. I plan to provide portions of the work, but I have hired the following person to coordinate, supervise and provide the major work (include name I address I phone/ contractors' license number):
5. I will provide some of the work, but I have contracted (hired) the following persons to provide the work indicated (include name I address I phone I type of work):
,IS PROPERTY OWNER SIGNATURE •AGENT OATE
COMPLETE THIS SECTION FOR NON-RESIDENTIAL BUILDING PERMITS ONLY
Is the applicant or future building occupant required to submit a business pla~ely hazardous materials registration form or risk management and prevention program under Sections 25505, 25533 or 25534 of the
Presley-Tanner Hazardous Substance Account Acrl Yes C!iQ...J D
Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air ~management district? Yes ~
Is the facility to be constructed within 1.000 feet of the outer boundary of a school site? Yes ~
IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY MAY NOT BE ISSUED UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF
EMERGENCY SERVICES A.NO THE AIR POLLUTION CONTROL DISTRICT.
CONSTRUCTION LENDING AGENCY
I hereby affirm that there is a construction lending agency for the performance of the work. this permit is issued {Sec. 3097 (i) Civil Code).
Lenders Name N O Li;;; N De {i. Lender's Address
APPLICANT CERTIFICATION
I certify that I have read the application and state that the aoove infonnatioo is colTeCt and that the !nfonnation on the plans is accurate. I agree to comply with all City ordinances and State laws relating to building construction.
I hereby authorize representative of the City of Cartsbad to enter upon the above mentklned property for inspection purposes. I ALSO AGREE TO SAVE, INDEMNIFY AI\ID KEEP HARMLESS THE CITY OF CARLSBAD
AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT.
OSHA: M OSHA permit is required for excavations over S'0' deep and demolition or construction of strucb.Jres over 3 stories in height.
EXPIRATION: Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void l the building or oork authorized by such permit is not commenced within
180 days from the date of such permit or if the building orv.ork authorized by such permit is suspended bandoned at any time after lhe oork is oommenced for a period of 180 days (Section 106.4.4 Unifoon Building Code).
~APPL~CANT'SSIGNATURE rLuPv ~-D-AT_E~~,____,/~1_, __ 1~,.~1,~-----
STOP: THIS SECTION NOT REQUIRED FOR BUILDING PERMIT ISSUANCE.
Complete the following ONLY if a Certificate of Occupancy will be requested at final inspection.
Fax (760) 602-8560, Email building@carlsbadca.gov or Mail the completed form to City of Carlsbad, Building Division 1635 Faraday Avenue, Carlsbad, California 92008.
CO#: (Office Use Only)
CONTACT NAME OCCUPANT NAME
o\DDRESS BUILDING ADDRESS
CITY STATE ZIP CITY STATE ZIP
Carlsbad CA
PHONE I FAX
EMAIL OCCUPANT'S BUS. LIC. No.
DELIVERY OPTIONS
PICKUP: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR (On Pg. 1)
ASSOCIATED CB#
MAIL TO: CONTACT (Listed above) OCCUPANT (Listed above)
CONTRACTOR !On Pg. 1) NO CHANGE IN USE/ NO CONSTRUCTION
MAIL/ FAX TO OTHER: --------------. --·· CHANGE OF USE/ NO CONSTRUCTION
-------. ,_,.,. ··--
65 APPLICANT'S SIGNATURE DATE
, . PERMIT INSPECTION HISTORY REPORT (CBC2018-0453)
Permit Type: BLDG-Commercial Application Date: 08/08/2018 Owner: P K I NORTH COUNTY PLAZA LP
Work Class: Tenant Improvement Issue Date: 10/10/2018 Subdivision: PARCEL MAP NO 15975
Stat:.is: Closed -Finaled Expiration Date: 05/29/2019 Address: 1846 Marron Rd
Carlsbad, CA 92008-1172
IVR Number: 13091
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re Inspection Complete
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 2nd phase sales floor Yes
BLDG-86 T-Bar, 075980-2018 Passed Michael Collins Complete
Ceiling Grids,
Overhead
Checklist Item COMMENTS Passed
BLDG-Building Deficiency 2nd phase sales floor. Yes
BLDG-Building Deficiency Not ready No
BLDG-14 1st phase, North side sales floor only Yes
Frame-Steel-Bolting-Welding
{Decks)
BLDG-14 10/29/18, 1st phase Back of House Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-34 Rough Electrical Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
Rough-Ducts-Dampers
BLDG-44 Yes
Rough-Ducts--Dampers
11/29/2018 11/29/2018 BLDG-Final 077276-201 B Partial PaH Michael Collins Re-inspection Incomplete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency TCO granted, see card Yes
BLDG-Electrical Final Yes
12106/2018 12/06/2018 BLDG-Final 078096-2018 Passed Michael Collins Complete
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency TCO granted, see card Yes
BLDG-Building Deficiency Yes
BLDG-Electrical Final Yes
December 06, 2018 Page 3 of3
PERMIT INSPECTION HISTORY REPORT (CBC2018-0453)
Permit Type: BLDG-Commercial Application Date: 08/08/2018 Owner: P K I NORTH COUNTY PLAZA LP
Work Class: Tenant Improvement Issue Date: 10/10/2018 Subdivision: PARCEL MAP NO 15975
Sta tu,;: Closed -Finaled Expiration Date: 05/29/2019 Address: 1846 Marron Rd
Carlsbad, CA 92008-1172
IVR Number: 13091
Scheduled Actual
Date Start Date Inspection Type Inspection No. Inspection Status Primary Inspector Re Inspection Complete
----·-··---
Checklist Item COMMENTS Passed
BLOG-Building Deficiency Not ready No
BLDG-14 10/29/18, 1st phase Back of House Yes
Frame-Steel-Bolting-Welding
(Decks)
BLD0-14 1st phase, North side sales floor only Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-34 Rough Electrical Yes
BLDG-34 Rough Electrical Yes
BLDG-44 Yes
RQugh-Ducts-Dampers
BLDG-44 Yes
Rough-Ducts..Dampers
10/31/2018 10131/2018 BLOG-91 074789-2018 Partial Pass Mfchael Collins Reinspection Incomplete
Complaints
Inspection
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Ok to occupy 1 s phase sales floor. Yes
11/07/2018 11/07/2018 BLDG-31 075597-2018 Paased Michael Collins Complete
Underground/Condu
It-Wiring
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase 1, North side, conduit only Yes
BLDG-Building Deficiency 2nd phase conduit only Yes
BLDG-84 Rough 075375-2018 Passed Michael Collins Complete
Combo(14,24,34,44)
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase 1, North side walls only Yes
BLDG-14 Yes
Frame-Steel-Bolting-Welding
(Decks)
BLOG-14 2nd phase, east side wall Yes
Frame-Steel-Bolting-Welding
(Decks)
BLDG-34 Rough Electrical Yes
BLDG-34 Rough Electrical Yes
11/08/2018 11/08/2018 BLDG-17 Interior 076663-2018 Passed Michael Collins Complete
Lath/Drywall
Checklist Item COMMENTS Passed
BLDG-Building Deficiency Phase 1, North side, one side wall screws Yes
BLDG-Building Deficiency Phase 2 wall for only Yes
BLOG-Building Deficiency Phase 1, south & west side of North walls. Yes
11/14/2018 11/14/2018 BLDG-34 Rough 076979-2018 Partlal Pass Michael Collins Reinspection Incomplete
Electrical
December 06, 2018 Page 2 of 3
, PERMIT INSPECTION HISTORY REPORT (CBC2018-0453)
Permit Type: BLDG-Commercial Application Date: 08/0812018 Owner:
Work Class:
Status:
Scheduled
Date
10/12/2018
10/1512018
10124/2018
10/25/2018
Tenant Improvement lssuo Date: 1011012018 Subdivision:
Closed -Finaled Expiration Date: 0512912019 Address:
Actual
Start Date
10/12/2018
10/1512018
10/24/2018
10(2612018
IVR Number: 13091
Inspection Type Inspection No.
BLDG-17 Interior 072956-2018
LathfOrywall
Checklist Item
BLDG-Building Deficiency
BLOG-31 072955-2018
Underground/Condu
it-Wiring
Checklist Item
BLDG-Building Deficiency
BLDG-84 Rough 072964-2018
Combo(14,24,34,44)
Checklist Item
BLDG-Building Deficiency
BLOG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-34 Ro1.1gh Electrical
BLDG-17 Interior 073138-2018
Lath/Drywall
Checklist Item
BLDG-Building Deficiency
BLDG-Building Deficiency
BLDG-85 T-Bar, 074137-2018
Celling Grids,
Overhead
Checklist Item
BLDG-Building Deficiency
BLDG-85 T-Bar, 074226-2018
Ceiling Grida,
Overhead
Checklist Item
BLDG-Building Deficiency
BLDG-14
Frame-Steel-Bolting-Welding
(Decks)
BLDG-34 Rough Electrical
BLDG-44
Rough-Ducts-Dampers
Inspection Status Primary Inspector
Partlal Pass Michael Collins
COMMENTS
Phase 1, North side, one side wall screws
Partial Pass Mlchael Collini
COMMENTS
Phase 1, North side, conduit only
Partial Pass Mlchael Collins
COMMENTS
Phase 1 , North side walls only
Partial Pass Michael Colllns
COMMENTS
Phase 1, North side, one side wall screws
Phase 1, south & west side of North walls.
Failed Michael Collins
COMMENTS
Not ready
Partial Pass Michael Collins
COMMENTS
Not ready
1st phase, North side sales floor only
10/29/2018 10/29/2018 BLDG--85 T-Bar,
Celling Grids,
Overhead
074529-2018 Partial Pass Michael Collins
P K I NORTH COUNTY PLAZA LP
PARCEL MAP NO 15975
1846 Marron Rd
Carlsbad, CA 92008-1172
Re inspection
Reinspection
Passed
Yes
Reinspection
Passed
Yes
Reinspectlon
Passed
Yes
Yes
Yes
Reinspection
Passed
Yes
Yes
Reinspection
Passed
No
Retnspection
Passed
No
Yes
Yes
Yes
Relnspection
Complete
Incomplete
Incomplete
Incomplete
Incomplete
Complete
Incomplete
Incomplete
----------------------------------------------
December 06, 2018 Page 1 of3
✓• EsG1I
A SAFEbuilfCompany
DATE: 9/6/18 • APPLICANT • JURIS.
JURISDICTION: Carlsbad
PLAN CHECK#.: cbc2018-0453
PROJECT ADDRESS: 1846 Marron Rd
PROJECT NAME: Verizon Retail Store TI
SET: II
•
•
•
•
•
~
•
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's building codes.
The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did adv7.·se the pplicant that the plan check has been completed.
Person contacted: ~ Telephone#:
Date contacted: (b~) Email:
Mail Telephone Fax In Person
0 REMARKS:
By: Jason Pasiut
EsGil
8/30/18
Enclosures:
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
✓• EsG1I
DATE: 8/21/18 • APPLICANT • JURIS.
JURISDICTION: Carlsbad
PLAN CHECK#.: cbc2018-0453
PROJECT ADDRESS: 1846 Marron Rd
PROJECT NAME: Verizon Retail Store TI
SETI
•
•
•
•
•
~
•
The plans transmitted herewith have been corrected where necessary and substantially comply
with the jurisdiction's codes.
The plans transmitted herewith will substantially comply with the jurisdiction's codes
when minor deficiencies identified below are resolved and checked by building department staff.
The plans transmitted herewith have significant deficiencies identified on the enclosed check list
and should be corrected and resubmitted for a complete recheck.
The check list transmitted herewith is for your information. The plans are being held at EsGil
until corrected plans are submitted for recheck.
The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant
contact person.
The applicant's copy of the check list has been sent to:
Fernando Cavazos, SGPA Architecture
EsGil staff did not advise the applicant that the plan check has been completed.
EsGil staff did advise the applicant that the plan check has been completed.
Person contacted: r,ernando Cavazos
Date conta . : n (by@) Email:
Mail ·'{itJ'elephone Fax In Person
REMAR
By: Morteza Beheshti by CM
EsGil
8/10/18
Telephone#: (619) 297-0131
fcavazos@sgpa.com
Enclosures:
9320 Chesapeake Drive, Suite 208 • San Diego, California 92123 • (858) 560-1468 • Fax (858) 560-1576
PLAN REVIEW CORRECTION LIST
TENANT IMPROVEMENTS
PLAN CHECK#.: cbc2018-0453
OCCUPANCY: M
TYPE OF CONSTRUCTION: VB
ALLOWABLE FLOOR AREA: No Change
SPRINKLERS?: Yes
REMARKS:
DATE PLANS RECEIVED BY
JURISDICTION:
DATE INITIAL PLAN REVIEW
COMPLETED: 8/21/18
FOREWORD (PLEASE READ):
JURISDICTION: Carlsbad
USE: Retail Store
ACTUAL AREA: 2626 TI only
STORIES: one
HEIGHT:
OCCUPANT LOAD: 43
DATE PLANS RECEIVED BY
ESGIL CORPORATION: 8/10/18
PLAN REVIEWER: Morteza Beheshti by CM
This plan review is limited to the technical requirements contained in the California version of
the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National
Electrical Code and state laws regulating energy conservation, noise attenuation and access for
the disabled. This plan review is based on regulations enforced by the Building Department.
You may have other corrections based on laws and ordinances enforced by the Planning
Department, Engineering Department, Fire Department or other departments. Clearance from
those departments may be required prior to the issuance of a building permit.
Code sections cited are based on the 2016 CBC, which adopts the 2015 IBC.
The following items listed need clarification, modification or change. All items must be satisfied
before the plans will be in conformance with the cited codes and regulations. Per Sec. 105.4 of
the 2015 International Building Code, the approval of the plans does not permit the violation of
any state, county or city law.
To speed up the recheck process, please note on this list (or a copy) where each
correction item has been addressed. i.e., plan sheet number. specification section, etc.
Be sure to enclose the marked up list when you submit the revised plans.
1. Please make all corrections and submit three new complete sets of prints, to:
EsGil, 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, (858)
560-1468 or directly to Carlsbad building department.
DISABLED ACCESS REVIEW LIST
DEPARTMENT OF STATE ARCHITECT
TITLE 24
The following disabled access items are taken from the 2016 edition of California Building
Code, Title 24. Per Section 1.9.1, all publicly and privately funded public accommodations
and commercial facilities shall be accessible to persons with disabilities.
REMODELS, ADDITIONS AND REPAIRS
NOTE: When alterations, structural repairs or additions are made to an existing building,
that building, or portion of the building affected, is required to comply with all of the
following requirements, per Section 11 B-202.4:
• The area of specific alteration, repair or addition must comply as "new"
construction.
• A primary entrance to the building and the primary path of travel to the
altered area, must be shown to comply with all accessibility features.
• The path of travel shall include the existing parking.
• Existing toilet and bathing facilities that serve the remodeled area must be
shown to comply with all accessibility features.
• ACCESSIBLE PARKING
2. Show that accessible parking space shown on the plans complies with Section
11 B-502.2 as follows:
a) Single spaces shall be 14' wide and outlined to provide a 9' parking area
and a 5' loading and unloading area. This loading/unloading area may be
on either side of the vehicle.
b) When more than one space is provided, in lieu of providing a 14' space for
each space, two spaces can be provided within a 23' area with a 5' loading
zone between each 9'0" wide space.
c) Each space is to be a minimum of 18' in depth.
3. At least one spaces(but not less than one) shall be served by an access aisle 8' in
width and designated as VAN ACCESSIBLE, per Section 11 B-208.2.4. This
loading/unloading area must be on the passenger side of the vehicle. Alternately,
the parking stall may be 12' wide with the access aisle 5' wide. Section 11 B-
502.3.4.
4. The words "NO PARKING" shall be painted on the ground within each loading and
unloading access aisle (in white letters no less than 12" high and located so that it
is visible to traffic enforcement officials). Section 11 B-502.3.3.
5. Show that detectable warnings, 36" deep and extending the full width of the curb
ramp, are to be installed for all curb ramps (regardless of slope), per Section 11 B-
705. Only approved DSNAC detectable warning products and directional surfaces
shall be installed. Section 11 B-705.3.
• DOORS
6. Note that the existing rest room doorways leading to sanitary facilities shall be
identified, per Section 11 B-703.7.2.6, as follows:
a) An equilateral triangle ¼" thick with edges 12" long and a vortex pointing
upward at men's rest rooms.
b) A circle¼" thick, 12" in diameter at women's rest rooms.
c) A 12" diameter circle with a triangle superimposed on the circle and within
the 12" diameter at unisex rest rooms.
d) The required symbols shall be centered on the door at a height of 58" -60".
e) Braille signage shall also be located on the wall adjacent to the latch
outside of the doorways leading to the sanitary facilities.
EXISTING SINGLE ACCOMMODATION FACILITIES
7. Detail on the plans sufficient space in the toilet room for a wheelchair to enter the
room and close the door, per Section 11 B-603.2. The space is required to be:
a) 2'.60" diameter.
b) AT-shaped space as shown in Figure 11 B-304.3.2.
c) Doors are not permitted to encroach into this space by more than 12
inches.
8. Show that the water closet is located in a space which provides:
a) A clear space at the water closet in compliance with Section 11 B-604.3.2
(this prohibits any fixtures from encroaching into the clear space at the rear
wall).
b) A clear space in front of the water closet measuring 60" wide by 48" in front.
Section 11 B-604.3.1. See the following figures.
i) Please notice that the 28" clearance required in the previous code
(between the water closet and the lavatory) has been changed to a
60" clearance as shown in the figure.
z
2
'· 60"MIN .
l CENTERLINE CENTERLINE i
j OF OF ! FIXTURE FIXTURE
11:-18" ~ MIN.
"]] ( () CJ N <{ '"1 28"Ml~I. ~ ~
.4::: v =te E86E FLUSH v1 8FWA'FER ~
ACTIVATOR J 6c:8SE'F " ON WIDE ~
SIDE ~( \
z a: i:'' ~ \ ::;; <{ ·""' «,"<" w 'bl;) c.,v I __,
co u <:>''?-.,,.
I \
'< /
I'.. ./ ---_.,
'
I
I 18" \ 32" MIN
MIN. ~R
(a)CLEARANCESATWAT&RCLORT
9. Doors may swing into the restroom as long as there is a clearance of at least 30" x
48" beyond the swing of the door. Section 118-603.2.3.
EXISTING RESTROOM FIXTURES AND ACCESSORIES
•··-·----··---·~·~-~••.,~·-·----
10. Show, or note, on the plans that the accessible water closets meet the following
requirements, per Sections 11 B-604.4 and 11 B-604.6:
a) The seat is to be ~17" but s19" in height.
b) The controls for flush valves shall be:
i) Mounted on the side of the toilet area.
ii) Be S44" above the floor.
11. Show, or note, on the plans that accessible urinals meet the following
requirements, per Section 11 B-605:
a) The rim of at least one urinal shall:
i) Project at least 13½ " from the wall.
ii) Be S17" above the floor.
b) The control mechanism is to be located S44" above the floor.
c) ~30" x 48" clear floor space is provided in front of the accessible urinal.
i) 36"x48" clear floor space when the urinal is located in an alcove that
exceeds 24" in depth, per section 11 B-305.7.1.
12. Show that accessible lavatories comply with the following, per Section 11 B-606:
13.
a) ~30" x 48" clear space is provided in front for forward approach. The clear
space may include knee and toe space beneath the fixture.
b) When lavatories are adjacent to a side wall or partition, there shall be a
minimum of 18" to the center line of the fixture to the wall.
c) The counter top is S34" maximum above the floor.
d) ~29" high, reducing to 27" at a point located 8" back from the front edge.
e) ~9" high x 30" wide and 17" deep at the bottom.
f) Hot water pipes and drain lines are insulated.
Show that grab bars comply with the following, per Sections 11 B-604.5 and 11 B-
609:
a)
b)
Grab bars shall be located on each side or one side and the back of the
water closet stall or compartment.
They shall be securely attached 33" -36" above the floor, and parallel.
c) Grab bars at the side shall be located:
i) Be ~42" long with the front end positioned 24" in front of the stool.
ii) Total length of bars at the back shall be ~36".
d) The diameter, or width, of the grab bar gripping surface is ~1 ¼" but S2", or
the shape shall provide an equivalent gripping surface.
If mounted adjacent to a wall, the space between the wall and the grab bar shall
be 1½".
The jurisdiction has contracted with EsGil, located at 9320 Chesapeake Drive, Suite
208, San Diego, California 92123; telephone number of 858/560-1468, to perform the
plan review for your project. If you have any questions regarding these plan review
items, please contact Morteza Beheshti at Esgil. Thank you.
[DO NOT PAY -THIS IS NOT AN INVOICE]
VALUATION AND PLAN CHECK FEE
JURISDICTION: Carlsbad
PREPARED BY: Morteza Beheshti by CM
BUILDING ADDRESS: 1846 Marron Rd
BUILDING OCCUPANCY: M
BUILDING AREA Valuation
PORTION ( Sq. Ft.) Multiplier
Tl 2626 City Est
Air Conditioning
Fire Sprinklers
TOTAL VALUE
Jurisdiction Code cb By Ordinance
-------,
1997 UBC Buildin Permit Fee g ..,., _J
1997 UBC Plan Check Fee
Type of Review: Complete Review
• Repetitive Fee ~I Repeats
• Other
0 Hourly
EsGil Fee
PLAN CHECK#.: cbc2018-0453
DATE: 8/21/18
Reg. VALUE ($)
Mod.
122,135
• Structural Only
$431.701
Comments: NA In addition to the above fee, an additional fee of$ is due ( hour@
$ /hr.) for the CalGreen review.
Sheet 1 of 1
• ~"'"' un:u,v I\C\:IIIVl'l-"'L
HAZARDOUS MATERIALS
QUESTIONNAIRE
RECORD ID# _________________ I
PLAN CHECK# ________________ !
BP DATE
P T II· I F T
ques ons a yes, app cant must contact e aunty o an Diego Haza
Call (858) 505-8700 prior to the Issuance of a building permit.
: If Iha answer to any of the
an Diego, CA 92123.
FEES ARE REQUIRED Project Completion Date: Expected Date of Occupancy:
YBES f (for new construction or remodeling projects)
1. Is your business listed on the reverse side of this form? (check all that apply).
2. WIii your business dispose of Hazardous Substances or Medical Waste In any amount?
3. WIU your business stare or handle Hazardous Substances In quantities greater than or equal to 55 gallons, 500
pounds and/or 200 cubic feet? D:• I WIii your business store or handle carclnogenslreproduclive toxins In any quantity? 4.
5.
6.
7.
8.
WIii your business use an existing or Install an underground storage tank?
WIii your business store or handle Regulated Substances (CalARP)?
WIii your business use or Install a Hazardous Waste Tank System (Title 22, Article 10)7
WIii your business store petroleum In tanks or containers at your facility with a total facility storage cepaclty equal to
or realer than 1,320 lions? California's NJ round Petroleum Sto Act .
0 CalARP Exempt
Date Initials
0 CalARP Required
Dale Initials
D CalARP Complete
Dale lnltlala
• Any YES• answer requires a stamp from APCD 10124 Old Grove Road, San
ego, . o stamp requ red If Q1 Yes lllll Q3 Yes 111111 Q4-Q6 NoJ. The following questions are Intended
to Identify the majo ty of air p on Issues at the planning stage. Projects may require additional measures not Identified by these questions. For comprehensive
requirements contact APCD. Residences are typlcaUy exem.r,i, except -those with more than one building• on the property; single buildings with more then four
i~iunl)town~o;~;.;~;;:;;;;;;;~~~•;;;:;~~;~~:::: a1::::l::~•=:~:•:0::n:: ::~:1:ulldlngs.J
3. ·w O (ANSWER ONLY IF QUESTION 1 or 2 IS YES) Hes an asbestos survey been parfonmed by a Certified Asbestos Consultant or Site Surveillance
J Technician? 4. 0 11!1, (ANSWER ONLY IF QUESTION 3 IS YES) Based on the survey results, will the project disturb any asbestos containing material? Notification
may be required 10 wotklng days prtor to commencing asbestos removal.
5. D 'l!!f. WIii the project or eeeoclated conatructlon equipment emit air contaminants? See the reverse side of !his form or APCD ractsheet
(WWW l!ll!Ps!l,gm/jQfgllaclf{p,pdf) for typical equipment requiring an APCD parmlt.
6. 0 0 (ANSWER ONLY IF QUESTION 5 IS YES) Will the project or associated construction equipment be located within 1,000 feet of a school
bound
Briefiy describe business activities: ,.,.-,-
t t~
Date
FOR OFFICAL USE ONLY:
FIRE DEPARTMENT OCCUPANCY CLASSIFICATION·
BY: DATE: I I
EXEMPT OR NO FURTHl!R INFORMATION RIQUIRID Rl!Ll!AIED FOR BUILDING Pl!llMIT •UT NOT FOR OCCUPANCY RELIAll!D FOR OCCUPANCY
COUNTY-HMO' APCD COUNTY-HMO APCD COUNTY-HMO APCD
\_\On Cor,t,.,. ~v o/ "-o ()
;z ~:m~~
(' oate/!niti~J
OC-\l'I••\-t ·s
"t.v of :,a\\
.. •A stamp m thJS box 2!1IJt: exempts businesses from completing or updating a Hazardous Matenals Business Plan. Other permitting requirements may still apply,
HM-9171 (08/15) County of San Diego -DEH -Hazardous Materials Division
INDUSTRIAL WASTEWATER DISCHARGE PERMIT
I I SCREENING SURVEY
Date 1} _ 'V I~
Busines~ N;me V~/l-\ 2. o ,-J WI 12.G L.ESS
Street Address l'ti (po /\J\l'ff:-f'ON "9/+0 (i¥1-S(51\;1) CA: "!~o'o
Email Address • I /M. VPrrJ DA-LFSe-rJ@ V€/l,,f Zf>,.J W't/1£,¢,$. {,,QM
PLEASE CHECK HERE IF YOUR BUSINESS IS EXEMPT: (ON REVERSE SIDE CHECK TYPE OF BUSINESS) -g
Check all below that are present at your facility: ~
Acid Cleaning Ink Manufacturing Nutritional Supplement/
Assembly Laboratory Vitamin Manufacturing
Automotive Repair Machining/ Milling Painting/ Finishing
Battery Manufacturing Manufacturing Paint Manufacturing
Biofuel Manufacturing Membrane Manufacturing Personal Care Products
Biotech Laboratory (i.e. water filter membranes) Manufacturing
Bulk Chemical Storage Metal Casting/ Forming Pesticide Manufacturing/
Car Wash Metal Fabrication Packaging
Chemical Manufacturing Metal Finishing Pharmaceutical Manufacturing
Chemical Purification Electroplating (including precursors)
Dry Cleaning Electroless plating Porcelain Enameling
Electrical Component Anodizing Power Generation
Manufacturing Coating (i.e. phosphating) Print Shop
Fertilizer Manufacturing Chemical Etching / Milling Research and Development
Film/ X-ray Processing Printed Circuit Board Rubber Manufacturing
Food Processing Manufacturing Semiconductor Manufacturing
Glass Manufacturing Metal Powders Forming Soap/ Detergent Manufacturing
Industrial Laundry Waste Treatment/ Storage
SIC Code(s) (if known): ~l /p,.
•
Brief description of business activities (Production/ Manufacturing Operations): _____ _
A-IL
Description of operations generating wastewater (discharged to sewer, hauled or evaporated):
N A-
Estimated volume of industrial wastewater to be discharged (gal/ day): _"1 .... /L~'-'-------
List hazardous wastes generated (type I volume): ---'"'..:.+/LCA-L.-___________ _
Date operation began/or will begin at this location: _r-J__,_"'"'l'r~------------
Have you applied for a Wastewater Discharge Permit from the Encina Wastewater Authority?
Yes (B9 If yes, when: ____________________ _
Site Contact__::,.t.!..!..::.!........:~-'--.--'<Ll..1'2....i.'-"'--'-.:'.__---Title Re1A1 L OG & I <P rJ 1 loN~'fi'l,1,t~ ~~~.P-
Signature Phone No. Cl 14 ) Z 70 -7 ~Do
ENCINA WA ORITY. 620 venida Encinas Carlsbad, CA 92011 (760) 438-3941
FAX: (760) 476-9852
~Gray
September 28, 2018
Carlsbad Building Dept
1635 Faraday Ave.,
Carlsbad, CA 92008
Dear Sir or Madam:
This letter hereby authorizes the undersigned Manuel Amador to sign for licenses and building
permits on behalf of Gray-I.C.E. Builders, Inc.
Respectfully,
~ek
Manuel Amador, Superintendent
A notary public or other officer completing this certificate verifies only the identity of the individual who
signed the document to which this certificate is attached, and not the truthfulness, accuracy, or validity of
that document.
State of California
County of Orange
On September 28, 2018 before me,J fk,(1. ~ '51 ·1.u: 1---personally appeared Brian Y. Silver who
proved to me on the basis of satisfactory evide; to be the person(~whose name('s.),__is/are subscribed to the
within instrument and acknowledged to me that he/sbe/tl=le•; executed the same in his/herftt,,eir authorized
capacity~and that by his/he0'tl ,ci, ;;gnature~on the instrument the perso~ or the entity upon behalf
of which the person(~cted, executed the instrument.
I certify under PENALTY OF PERJURY under the laws of the State of California that the foregoing paragraph is
true and correct.
P: r ,::c1·1·iti/c; ,c\vPnue I /\ric1lw11n, C/\ {)280'1 I I / 1-l.'flJ I. I l I 7 I~ 11.·1.31 ;_ 9711Ll
"•Ii