Loading...
HomeMy WebLinkAbout187 CHERRY AVE; ; CB161974; Permit (2)Building Permit Finaled Residential Permit Print Date: 10/06/2020 Job Address: 187 CHERRY AV, CARLSBAD, CA 92008 Permit Type: BLDG-Residential Work Class: Parcel#: 2042320100 Track #: Valuation: $478,796.00 Lot#: Occupancy Group: #of Dwelling Units: 1 Project#: Plan#: Bedrooms: Construction Type: Condo 3 DEV15033 Bathrooms: Orig. Plan Check#: PC160031 Plan Check#: Project Title: CHERRYFIELD BEACH HOMES Status: Applied: Issued: (city of Carlsbad Permit No: CB161974 Closed -Finaled 05/19/2016 10/11/2017 Finaled Close Out: Inspector: Final Inspection: TFraz 10/06/2020 Description: CHERRYFIELD TOWNHOMES:(UNIT 3) 3,372 SF LIV// 421 SF GAR// 574 SF DECKS FEE BUILDING PERMIT FEE $2000+ BUILDING PLAN CHECK FEE (BLDG) ELECTRICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL GREEN BUILDING STANDARDS PLAN CHECK & INSPECTION MECHANICAL BLDG RESIDENTIAL NEW/ADDITION/REMODEL PLUMBING BLDG RESIDENTIAL NEW/ADDITION/REMODEL PUBLIC FACILITIES FEES -outside CFD SB1473 GREEN BUILDING STATE STANDARDS FEE STRONG MOTION-RESIDENTIAL WATER METER FEE 1" Displacement Total Fees: $20,231.S7 Total Payments To Date: $20,231.57 CoApplicant: PROPHET SOLUTIONS INC 5845 AVENIDA ENCINAS, # 138 CARLSBAD, CA 92008-4432 (760) 999-2146 Balance Due: AMOUNT $1,971.45 $880.02 $66.00 $166.00 $92.00 $182.00 $16,757.86 $20.00 $62.24 $34.00 $0.00 Please take NOTICE that approval of your project includes the "Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exaction." You have 90 days from the date this permit was issued to protest imposition of these fees/exactions. If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3.32.030. Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition. You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project. NOR DOES IT APPLY to any fees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitation has previously otherwise expired. Building Division Page 1 of 1 1635 Faraday Avenue, Carlsbad CA 92008-7314 I 760-602-2700 I 760-602-8560 f I www.carlsbadca.gov PERMIT INSPECTION HISTORY for (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTT A Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 187 CHERRY AV IVR Number: 714643 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No, Inspection Primary Inspector Reinspection Inspection Date Start Date Status 06/22/2020 06/22/2020 BLDG-34 Rough 130776-2020 Passed Paul Burnette Complete Electrical Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 09/08/2020 09/08/2020 BLDG-Final Inspection 137614-2020 Failed Paul Burnette Re inspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-Plumbing Final No BLDG-Mechanical Final No BLDG-Structural Final No BLDG-Electrical Final No 10/06/2020 10/06/2020 BLDG-Final Inspection 140238-2020 Passed Paul Burnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-Plumbing Final Yes BLDG-Mechanical Final Yes BLDG-Structural Final Yes BLDG-Electrical Final Yes Tuesday, October 6, 2020 Page 5of5 PERMIT INSPECTION HISTORY for (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTTA Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 187 CHERRY AV IVR Number: 714643 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status Checklist Item COMMENTS Passed BLDG-Building Deficiency 6" rigid foam over vaulted area Yes 03/04/2019 03/04/2019 BLDG-84 Rough 084969-2019 Passed Tim Frazee Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-14 Yes Frame-Steel-Bolting-Welding (Decks) BLDG-24 Rough-Topout Yes BLDG-34 Rough Electrical Yes BLDG-44 Yes Rough-Ducts-Dampers 03/14/2019 03/14/2019 BLDG-16 lnsulatlon 086151-2019 Passed Tim Frazee Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency 6" rigid foam over vaulted area Yes Wall and Ceiling insulation OK 3/14/19 04/01/2019 04/01/2019 BLDG-17 Interior 087574-2019 Passed Tim Frazee Complete Lath/Drywall Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 05/08/2019 05/08/2019 BLDG-84 Rough 091169-2019 Passed Tim Frazee Complete Combo(14,24,34,44) Checklist Item COMMENTS Passed BLDG-14 Steel stud soffit framing OK Yes Frame-Steel-Bolting-Welding (Decks) 02/14/2020 02/14/2020 BLDG-21 119528-2020 Passed Michael Co111ns Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Build in supply from meter to unit Yes 04/15/2020 04/15/2020 BLDG-23 124813-2020 Passed Michael Co111ns Complete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE, includes 187 HM Yes BLDG-Electric Meter 124937-2020 Passed Michael Collins Complete Release Checklist Item COMMENTS Passed BLDG-Building Deficiency EMR emailed to SDGE, includes 187 HM Yes Tuesday, October 6, 2020 Page 4 of 5 PERMIT INSPECTION HISTORY for (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTTA Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 187 CHERRY AV IVR Number: 714643 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 09/18/2018 09/18/2018 BLDG-11 070338-2018 Passed Paul Burnette Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency HSS column tie in, see card. Yes 10/09/2018 10/0912018 BLDG-15 Roof/ReRoof 072213-2018 Partial Pass Chris Renfro Reinspection Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency Flat roof deck Nailing. OK to build cricket. Yes Need height certification before roof inspection. 11/13/2018 11/13/2018 BLDG-15 Roof/ReRoof 075872-2018 Partial Pass Michael Colllns Reinspection Incomplete (Patio) Checklist Item COMMENTS Passed BLOG-Building Deficiency Flat roof deck Nailing. OK to build cricket. Yes Need height certification before roof inspection. BLDG-Building Deficiency Upper roof except stair tower Yes 12/1112018 12/11/2018 BLDG-23 078456-2018 Partial Pass Paul Burnette Reinspection Incomplete Gas/Test/Repairs Checklist Item COMMENTS Passed BLDG-Building Deficiency No 12/1312018 12/13/2018 BLDG-15 Roof/ReRoof 078761-2018 Partial Pass Michael Colllns Reinspectlon Incomplete (Patio) Checklist Item COMMENTS Passed BLDG-Building Deficiency OSB over rigid foam Yes BLDG-Building Deficiency Flat roof deck Nailing. OK to build cricket. Yes Need height certification before roof inspection. BLDG-Building Deficiency Upper roof except stair tower Yes BLDG-16 Insulation 078762-2018 Partial Pass Michael Collins Reinspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency 6" rigid foam over vaulted area Yes 01/04/2019 01/04/2019 BLDG-13 Shear 080485-2019 Passed Tim Frazee Complete Panels/HD (ok to wrap) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 0211212019 02112/2019 BLDG-16 Insulation 083657-2019 Partial Pass Paul Burnette Reinspection Incomplete Tuesday, October 6, 2020 Page 3 of 5 PERMIT INSPECTION HISTORY for (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTT A Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 187 CHERRY AV IVR Number: 714643 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status BLDG-22 Sewer/Water 052535-2018 Passed Michael Collins Complete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste to POC Yes 04/12/2018 04/12/2018 BLDG-21 054762-2018 Passed Paul Burnette Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 04/17/2018 04/17/2018 BLDG-11 055223-2018 Partial Pass Michael Collins Relnspection Incomplete Foundatlon/Ftg/Plers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency HSS column tie in, see card. Yes BLDG-24 RoughfTopout 055224-2018 Partial Pass Michael Collins Re inspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Underground storm drain POC tie in. Yes 04/30/2018 04/30/2018 BLDG-11 056435-2018 Partial Pass Paul Burnette Reinspection Incomplete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency HSS column tie in, see card. Yes 05/10/2018 05/10/2018 BLDG-11 057634-2018 Partial Pass Paul Burnette Reinspection Incomplete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency HSS column tie in, see card. Yes 09/12/2018 0911212018 BLDG-14 069769-2018 Failed Michael Collins Reinspection Incomplete Frame/Steel/Bolting/We ldlng (Decks) Checklist Item COMMENTS Passed BLDG-Building Deficiency Not ready No BLDG-24 RoughfTopout 069771-2018 Partial Pass Michael Collins Relnspection Incomplete Checklist Item COMMENTS Passed BLDG-Building Deficiency Underground storm dr3in POC tie in. Yes BLDG-Building Deficiency Underground waste to POC for laundry Yes sink Tuesday, October 6, 2020 Page 2 of 5 Building Permit Inspection History Finaled (city of Carlsbad PERMIT INSPECTION HISTORY for (CB161974) Permit Type: BLDG-Residential Application Date: 05/19/2016 Owner: MATTHEW CASTRIOTTA Work Class: Condo Issue Date: 10/11/2017 Subdivision: Status: Closed -Finaled Expiration Date: 12/21/2020 Address: 187 CHERRY AV IVR Number: 714643 CARLSBAD, CA 92008 Scheduled Actual Inspection Type Inspection No. Inspection Primary Inspector Reinspection Inspection Date Start Date Status 11/21/2017 11/21/2017 BLDG-11 041159-2017 Passed Michael Collins Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Lower CMU footing/steel Yes 12111/2017 12/11/2017 BLDG-11 042979-2017 Passed Chris Renfro Complete Foundation/Fig/Piers (Rebar) Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes BLDG-66 Grout 042978-2017 Passed Chris Renfro Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/04/2018 01/04/2018 BLDG-66 Grout 045012-2018 Passed Paul Bu'rnette Complete Checklist Item COMMENTS Passed BLDG-Building Deficiency Yes 01/26/2018 01/26/2018 BLDG-12 Steel/Bond 046975-2018 Partial Pass Andy Krogh , Reinspectlon Incomplete Beam Checklist Item COMMENTS Passed BLDG-Building Deficiency 8" poured in place wall at shoring/ stairwell Yes 03/14/2018 03114/2018 BLDG-21 051718-2018 Failed Paul Burnette Relnspection Incomplete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency No BLDG-22 Sewer/Water 051719-2018 Failed Paul Burnette Reinspection Incomplete Service Checklist Item COMMENTS Passed BLDG-Building Deficiency No 0312212018 0312212018 BLDG-21 052534-2018 Passed Michael Collins Complete Underground/Underflo or Plumbing Checklist Item COMMENTS Passed BLDG-Building Deficiency Waste to POC with 6 inch sewer BF Yes device. Tuesday, October 6, 2020 Page 1 of 5 .. --·----- bHA,lnc. land planning, civil engineering, surveying October 9, 2018 w.o. 1001-1113-100 Mr. Paul Burnette Building Inspector CITY OF CARLSBAD Community and Economic Development Building Division 1635 Faraday Avenue Carlsbad, CA 92008 ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Engineer RE: ROOF HEIGHT ~RIFICATION OF UNITS 1 THRU 3, 187, 191 & 195 CHERRY AVENUE, CHERRY-FIELD BEACH HOMES, MS 15-08 Dear Mr. Burnette: This letter is to attest that BHA, Inc. has surveyed the roof height of the building for the above-mentioned project. The top ofroof elevation for the center ridge line is shown on the building plans dated 01-04- 2018 as 91.0'. We have surveyed the elevation of the existing roof at the center ridge line as 90.94'. The top of roof elevation for the flat roof is shown on the building plans dated 01-04-2018 as 85.0'. We have surveyed the elevation of the existing flat roof as 84.93'. If you have any questions regarding this matter, please contact our office. Sincerely, bl-iA, Inc. •~ \1'ITJl"V'-"'U\;V{.)\/ Ronald L. Holloway Senior Vice President RCE29271 RH:rh cc: Matthew Castrlotta Randy Smith -Prophet Solutions K:\Land Projects 3\826-1113-600\survey\toof height-verification-cherry.wpd 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 o (760) 931-8700 o FAX (760) 931-77B0 CTE sou111 INSPECTION REPORT Page Job No. Report No. 1 of --- I0-13893T ------- PROJECT NAME Cherry Field Beach Homes INSPECTION MATERIAL INDENTIFICATION ADDRESS 187, 189, 191 Cherry Street □ CONCRETE CONG. MIX NO. & lb/in2 Carlsbad, CA 92009 □ REINF. STEEL GROUT MIX NO. & lb/in2 ARCHITECT □ MASONRY MORTOR TYPE & lb/in2 ENGINEER □ P.T. CONCRETE REINF. STEEL GR./SIZE CONTRACTOR Prophet Solution, Inc. 0 FIELD WELDING STRUCTURAL STEEL OTHER □ SHOP WELDING HIGH-STRENGTH BOLT INSPECTION DATE Wednesday, April 11, 2018 □ BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER □ EXP. ANCHOR OTHER BLDG. PERMIT/OTHER □ OTHER MATERIAL SAMPLING 0 CONCRETE 0 MORTAR 0 GROUT 0 BOLTS 0 REINFORCING STEEL 0 STRUCTRUAL STEEL 0 FIREPROOFING 0 MASONRY BLOCK 0 OTHER 0 OTHER INSPECTION PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES Arrived at Cherry Street, Carlsbad CA for welding inspection. Reviewed plans and Specifications, verified welders cert., WPS, welding parameter (Volts and Amps). Welder: Rosen o Fernan ez pe orme Wit A5. , -d d rfi d . h AWS 20 E71T 8 NR232 Items observed Gridline Details/Drawings Status/Remarks Welding ofrebar to column Line E2. l/4, E3/3, 7/-Work in Progress E3/4, F/3, F/4 Welding of angle iron to column and rebar Line F/3, F/4, E3/4, 6/-Work in Progress E2. l/4 End of Report. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINT NAME Hieu Nguyen ---------""-"--------SIGNATURE ~ CERT IF IC AT 10 N NO. fCC#87 l 9355 TIME IN 8:00 AM TIME OUT 4:00 PM 14442 Meridian Parkway, Suite A \ Riverside, CA 92518 Ph (951) 571-4081 \ Fax (951) 571-4188 \ www.cte-inc.net Inspection \ Testing \ Geotechnical \ Environmental \ Construction Engineering \ Civil Engineering \ Surveying CTE sou1H INSPECTION REPORT Page Job No. Report No. of I0-13893T -------- PROJECT NAME Cherry Field Beach Homes INSPECTION MATERIAL INDENTIFICATION ADDRESS 187, 189, 191 Cherry Street □ CONCRETE CONG. MIX NO. & lb/in2 Carlsbad, CA 92009 □ REINF. STEEL GROUT MIX NO. & lb/in2 ARCHITECT □ MASONRY MORTOR TYPE & lb/in2 ENGINEER □ P.T. CONCRETE REINF. STEEL GR./SIZE CONTRACTOR Prophet Solution, Inc. 0 FIELD WELDING STRUCTURAL STEEL OTHER □ SHOP WELDING HIGH-STRENGTH BOLT INSPECTION DATE Monday, April 16, 2018 □ BATCH PLANT MASONRY BLOCK PLAN FILE/OTHER □ EXP. ANCHOR OTHER BLDG. PERMIT/OTHER □ OTHER MATERIAL SAMPLING 0 CONCRETE 0 MORTAR 0 GROlfT 0 BOLTS 0 REINFORCING STEEL 0 STRUCTRUAL STEEL 0 FIREPROOFING 0 MASONRY BLOCK 0 OTHER 0 OTHER INSPECTION PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES Arrived at Cherry Street, Carlsbad CA for welding inspection. Reviewed plans and Specifications, verified welders cert., WPS, welding parameter (Volts and Amps). W Id R d F d £ d . h AWS AS 20 E71T 8 NR232 e er: osen o ernan ez per orme Wit , - Items observed Gl'idline Details/Drawings Status/Remarks Welding ofrebar to column Line E2.l, E3, F, 7 7/-Work Completed. VIOK Welding of angle iron to column and rebar Line F, E3, E2.l,, 7 6/-Work Completed. VIOK End of Report. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINT NAME Hieu Nguyen --------~~------SIGNATURE ~ CERT IF IC AT 10 N NO. ICC#8719355 TIME IN 8:00 AM TIME OUT 12:00 PM 14442 Meridian Parkway, Suite A I Riverside, CA 92518 Ph (951) 571 -4081 I Fax (951) 571-4188 I www.cte-inc.net Inspection I Testing I Geotechnical I Environmental Construction Engineering I Civil Engineering I Surveying b~A,lnc. land planning, civil engineering, surveying November 29, 2017 w.o. 1001-1113-600 Mr. Paul Burnette Senior Building Inspector CITY OF CARLSBAD Community and Economic Development Building Division 1635 Faraday Avenue Carlsbad, CA 92008 ROD BRADLEY, Urban Planner RONALD L. HOLLOWAY, Civil Engineer RE: BUILDING IAYOUT AND SET BACK VERIFICATION OF UNITS 1, 2 AND 3, CHERRY-FIELD BEACH HOMES, MS 15-08 Dear Mr. Burnette: This letter is to attest that BHA, Inc. has staked the location for the building construction on the above-mentioned units. In addition we have checked the layout of the proposed building and found the horizontal and vertical location to conform to the grading plans prepared by our office. If you have any questions regarding this matter, please contact our office. Sincerely, I Vice President PLS5941 AAM: cc: Randy Smith -Prophet Solutions PI..S5941 5115 Avenida Encinas, Suite L o Carlsbad, California 92008-4387 ° (760) 931-8700 o FAX (760) 931-7780 Construction Testing & Engineering, Inc. Inspection I Testing I Geotechnical I Environmental & Construction Engineering I Civil Engineering I Surveying INSPECTION REPORT PROJECT NAME CAeLnt h(.t( h'11?.d &w~C I ' ADDRESS 111115'.S 191 d,c,,,., live 1)/ 01,< L~ ba< I ARCHITECT 1r,,,,. <: ~ci/4 kl. ileds I/ -1 •-• ENGINEER /,& G.C?~VtJ /:?~1 t1/Jl,lt1~17 CONTRACTOR ,FJty;A~ t >4,k/;, ~ Y 5 OTHER INSPECTION DATE PLAN FILE/OTHER /1-17 -Fl: BLDG. PERMIT/OTHER re I b/20:: 1 INSPECTION □ CONCRETE Jl) REINF. STEEL □ MASONRY □ P.T. CONCRETE □ FIELD WELDING □ SHOP WELDING □ BATCH PLANT □ EXP.ANCHOR □ OTHER MATERIAL SAMPLING PAGE _j_ OF -1-- CTE JOB NO. / (') ~---- REPORT NO. MATERIAL IDENTIFICATION CONC. MIX NO. & lb/in2 GROUT MIX NO. & lb/in2 MORTAR TYPE & lb/in2 REINF. STEEL GR./SIZE/94/?' 0JcJ STRUCTURAL STEEL /J 7t1 71 • C, O HIGH-STRENGTH BOLT MASONRY BLOCK OTHER □ CONCRETE □ MORTAR □ GROUT □ REINFORCING STEEL □ STRUCTURAL STEEL □ FIREPROOFING □ MASONRY BLOCK □ BOLTS □ OTHER INSPECTIONS PERFORMED, MATERIAL IDENTIFICATION, PROGRESS, WORK REJECTED, REMARKS PLEASE NOTE ANY RE-INSPECTION, TESTING, OR OTHER PROJECT ISSUES. J --1( ,Ax ,r:i,l:vtu' pt tyA ft, ,112yJ f ~ u,Lc,t.< ,t t= N.ld S / ('..C f-~ cf J ;~'.'%:.: =~z:t;,b/4, /2~/I &«y/,t,-/4,;. Certification of Compliance: All work, unless otherwise noted, complies with applicable codes and the approved plans and specifications. PRINTED NAME .µ,'f,t/Jl)' /1~/4,.~ CERTIFICATION NO. ~ Ji ,2 z;J K/'.i(?.~'57j.2/ 1441 Montiel Road, Suite 115 I Escondido, CA 92026 I Ph (760) 746-4955 I Fax (760) 746-9806 I www.cte-inc.net Construction Testing & Engineering, Inc. IIJlllldfon I ~ I Geot1cl111icat I Enw11■111,lllll I CanltnJdlon Efla"-IIV I CMI Eflal~ I &na,kv DAILY FIELD REPORT Client: Job Number: 10-13893T Job Name: Cherry Field Beach Homes Oay(s): Wednesday Job Location: 187-189-191 Charry Street, Carlsbad, Califomia Date(&): 11-08-2017 Gen. Contractor. Prophet Solutions Sub-Contractor(&): General Description: On Location as requested to provide observation and documentation of proposed residential Bldg. and retaining wall footing excavations. Residential Bldg. and retaining wall excavation locations are betwNn grid lines B thru F and between grid Hnes 1 thru 7.Used a steel probe on residential throughout footing bottom excavallons and retaining wall footing excavation bottoms, found all open footing excavation bottoms to be. firm and unyielding. Proposed residential Bldg. and retaining wall excavation footing bottoms material consists of fine grained sanely sand with a low to medium expansivl!I index level. Depth and width dimensions of proposed residential Bldg. and retaining wall footings ant In the acc:ordance with on-site clvll plans and Is incompllance with CTE 10ils report 19001111Ylandalions as per plan. COMMENTS/ AREAS OF ADDITIONAL CONCERN: BY: DATE: 11/08/2017 "l)a,,,u(~ 1441 MONTIEL ROAD ESCONDIDO, CA 92028 (780) 746-4955 FAX (7110) 748-98011