Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
1923 CALLE BARCELONA; 147; CB090700; Permit
06-01-2009 City of Carlsbad 1635 Faraday Av Carlsbad, CA 92008 Commercial/Industrial Permit Permit No Building Inspection Request Line (760) 602-2725 CB090700 Job Address Permit Type Parcel No Valuation Occupancy Group Project Title 1 923 CALLE BARCELONA CBADSt 147 Tl Sub Type COMM 2550120400 Lot# 0 $31,22000 Construction Type 5B NUBONAU- 892 SF TI-STOREFRONT, MINOR ELECT & LIGHTS, MINOR PLUMBING Applicant MARK SWENSON STE 200 6125 CORNERSTONE CT 92121 858 866-0889 Owner Status Applied Entered By Plan Approved Issued Inspect Area Plan Check* ISSUED 04/28/2009 RMA 06/01/2009 06/01/2009 Building Permit Add'l Building Permit Fee Plan Check Add'l Plan Check Fee Plan Check Discount Strong Motion Fee Park Fee LFM Fee Bridge Fee BTD #2 Fee BTD #3 Fee Renewal Fee Add'l Renewal Fee Other Building Fee Pot Water Con Fee Meter Size Add'l Pot Water Con Fee Reel Water Con Fee Green Bldg Stands (SB1473) Fee $300 30 Meter Size $0 00 Add'l Reel Water Con Fee $19520 Meter Fee $0 00 SDCWA Fee $0 00 CFD Payoff Fee $656 PFF (3105540) $0 00 PFF (4305540) $0 00 License Tax (3104193) $000 License Tax (4304193) $000 Traffic Impact Fee (3105541) $0 00 Traffic I mpact Fee (4305541) $0 00 PLUMBING TOTAL $0 00 ELECTRICAL TOTAL $0 00 MECHANICAL TOTAL $0 00 Master Drainage Fee Sewer Fee $0 00 Redev Parking Fee $0 00 Additional Fees $1 00 HMP Fee TOTAL PERMIT FEES $000 $000 $000 $000 $000 $000 $000 $000 $000 $000 $4800 $2000 $000 $000 $000 $000 $000 77 $571 06 Total Fees $571 06 Total Payments To Date $571 06 Balance Due $000 BUILDING PLANS \/ IN STORAGF. ATTACHED Inspector >R>ROVAL ' I I & ( t——-1 FINAL APPROVAL Date .Clearance NOTICE Please take NOTICE that Approval of your project includes the Imposition" of fees, dedications, reservations, or other exactions hereafter collectively referred to as "fees/exactions" You have 90 days from the date this permit was issued to protest imposition of these fees/exactions If you protest them, you must follow the protest procedures set forth in Government Code Section 66020(a), and file the protest and any other required information with the City Manager for processing in accordance with Carlsbad Municipal Code Section 3 32 030 Failure to timely follow that procedure will bar any subsequent legal action to attack, review, set aside, void, or annul their imposition You are hereby FURTHER NOTIFIED that your right to protest the specified fees/exactions DOES NOT APPLY to water and sewer connection fees and capacity changes, nor planning, zoning, grading or other similar application processing or service fees in connection with this project NOR DOES IT APPLY to any tees/exactions of which you have previously been given a NOTICE similar to this, or as to which the statute of limitations has previously otherwise expired ' City of Carlsbad 1635 Faraday Ave , Carlsbad, CA 92008 760-602-2717 / 2718 / 2719 Fax 760-602-8558 www carlsbadca gov Building Permit Application JOB ADDRESS "CT/TROJECT J DESCRIPTION OF WORK Include Square Feet of Affected Area(s) ffbTA/l- Tf f fOfetJ C-ragif^/vrr; ^/frfrr/A^ ^U^AJ/90 • Mf^0£/^/ff L_ EXISTING USE 1&Trt/L M PROPOSED USE /r? GARAGE (SF)PATIOS (SF)DECKS (SF)FIREPLACE YES D # _ NO D AIR CONDITIONING YES Q NO D FIRE SPRINKLERS YES D NO D CONTACT NAME (If Different Fom Applicant) ADDRESS APPLICANT NAME ADDRESS CITY PHONE" STATE ZIP EMAIL EMAIL PROPERTY OWNER NAME ADDRESS CITY PHONY" STATE ZIP FAX EMAIL ARCH/DESIGNER NAME & ADDRESS STATE LIC *CITY BUS LIC II [Set 7031S Business and Professions Code Any City or County which requires a permit to construct alter, improve demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement that he is licensed pursuant to the provisions o( the Contractor s License Law (Chapter 9 commending with Section 70QQ of Division 1 of the Business and Professions Code) or that he is exempt there from and the basis for the alleged exemption Any violation of Section /Oil S by any applicant for a permit subjects the applicant to a civil penally of not more than five hundred dollars {$500}) l3i^%^'j<?iltl"-'^'i •*••"•••?• 'i^'^.-';r'-v/d---!S:,i?v^?,*^f.-."®s^:-.'i''"-" .-r-fc-.-^:/..£;V-1 Workers Compensation Declaration / hereby affirm under penalty of perjury one of the following declarations LTI I have and will maintain a certificate of consent to self insure for workers compensation as provided by Section 3700 of the Labor Code, for the performance of the work for which this permit is issued SS I have and will maintain workers--epmper»sation as-tequired bv Section 3700 of the Labor Code for the performance of tte work tor which this permit is issued My workers compensation insurance carrier and policy number are Insurance Co ^nft^fO T\J|/Lflf Policy No fffi) B^aO / "" /-P/>7 Expiration Date T7J^//^ This section need not be completed if the permit is for one hundred dollars ($100) or less O Certificate of Exemption I certify that in the performance of the work for which this permit is issued I shall not employ any person in any manner so as to become sublet to the Workers Compensation Laws of California WARNING Failure to secure workers' compensation coverage is unlawful, and shall subject an employer to criminal penalties and civil fines up to one hundred thousand dollars (&100,000), in addition to the cost of compensation, damagosas provided for in Section 3706 of th&cabor code, interest and attorney's fees jglf CONTRACTOR SIGNATURE USMA DATE $$wy ••*''•* ^ / hereby affirm lhal I am exempt from Contractor s License Law for (he following reason Cl I as owner of the property or my employees with wages as their sole compensation will do the work and the structure is not intended or offered for sale (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and who does such work himself or through his own employees provided that such improvements are not intended or offered for sale If however the building or improvement is sold within one year of completion the owner builder will have the burden of proving that he did not build or improve for the purpose of sale) f) I as owner of the property am exclusively contracting with licensed contractors to construct the project (Sec 7044 Business and Professions Code The Contractor s License Law does not apply to an owner of property who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor s License Law) Cl I am exempt under Section Business and Professions Code for this reason 1 I personally plan to provide the major labor and materials for construction of the proposed property improvement D Yes CJ No 2 I (have / have not) signed an application for a building permit for the proposed work 3 I have contracted with the following person (firm) to provide the proposed construction (include name address / phone / contractors license number) 4 I plan lo provide portions of the work but I have hired the following person to coordinate supervise and provide the major work (include name / address / phone / contractors license number) 5 I will provide some of the work but I have contracted (hired) the following persons to provide the work indicated (include name / address / phone / type of work) ^PROPERTY OWNER SIGNATURE DATE Is the applicant or future building occupant required to submit a business plan acutely hazardous materials registration form or risk management and prevention program under Sections 25505 25533 or 25534 of the Presley Tanner Hazardous Substance Account Act7 D Yes Cl No Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 D Yes fl No Is the facility to be constructed within 1 000 feet of the outer boundary of a school site7 Cl Yes a No IF ANY OF THE ANSWERS ARE YES, / EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT I hereby affirm that there is a construction lending agency for the performance of the work this permit is issued (Sec 3097 (i) Civil Code) Lender's Name Lenders Address I certify that I have read Uie application and state that the above information is correct and that the information on the plans is accurate I agree to comply with all City ordinances and State laws relating to building construction I hereby authorize representative of the City of Carlsbad lo enter upon the above mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS, COSTS AND EXPENSES WHICH MAY IN ANY WAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT OSHA An OSHA permit is required for excavations over 5 0 deep and demolition or construction of structures over 3 stones in height EXPIRATION Every permit issued by the Building Official under the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or work authorized by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 106 4 4 Uniform Building Code) ^APPLICANT'S SIGNATURE DATE City of Carlsbad Final Building Inspection •aSbt<r?iTjy>gjpJ Dept Building Engineering Planning CMWD St Lite/ 'Fire Plan Check # Permit# Project Name Address Contact Person Sewer Dist Inspected Bv / Inspected Bv Inspected Bv CB090700 NUBONAU- 892 MINOR ELECT SFTI-STOREFRONT, & LIGHTS, MINOR PLUMBING 1923 CALLE BARCELONA #147 TOM LC !,,J)J\A/ 6 Phone 6197273884 Water Dist O / Date A l.A Inspected 0M 1)*\ \v Date Inspected Date Inspected Date 07/24/2009 Permit Type Tl Sub Type COMM Lot 0 1 Approved iS Disapproved L Approved Disapproved Approved Disapproved Comments City of Carlsbad Bldg Inspection Request For 08/05/2009 Permit* CB090700 Title NUBONAU- 892 SF TI-STOREFRONT, Description MINOR ELECT & LIGHTS, MINOR PLUMBING Inspector Assignment PY 1923 CALLE BARCELONA 147 Lot 0 Type Tl Sub Type COMM Job Address Suite Location APPLICANT MARKSWENSON Owner Remarks Phone 6197273884 Inspector Total Time CD Description 19 Final Structural 29 Final Plumbing 39 Final Electrical 49 Final Mechanical Requested By TOM Entered By CHRISTINE Act Comments Comments/Notices/Holds Associated PCRs/CVs Original PC# CV070333 CLOSED O- EXPIRED BUSINESS LICENSE, Inspection History Date Description Act Insp Comments 07/24/2009 89 Final Combo NR PY 07/07/2009 14 Frame/Steel/Bolting/Weldmg AP PY 07/01/2009 24 Rough/Topout AP PY 06/30/2009 18 Exterior Lath/Drywall AP PY 06/30/2009 24 Rough/Topout NR PY 06/29/2009 84 Rough Combo PA PY 06/18/2009 21 Underground/Under Floor AP PY 06/18/2009 22 Sewer/Water Service WC PY 06/15/2009 34 Rough Electric AP PY EsGil Corporation In (Partnership with government for Quitting Safety DATE 5/21/09 JURIS JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO O9-O70O SET I PROJECT ADDRESS 1923 Calle Barcelona PROJECT NAME Nubonau - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person The applicant's copy of the check list has been sent to Esgil Corporation staff did not advise the applicant that the plan check has been completed Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Telephone # Date contacted (by ) Fax # Mail Telephone Fax In Person REMARKS By Doug Moody Enclosures EsGil Corporation D GA D MB D EJ D PC 4/30/09 9320 Chesapeake Drive, Suite 208 4 San Diego, California 92123 * (858)560-1468 + Fax (858) 560-1576 EsGil Corporation In (Partnership with government for (Buiftfing Safety DATE 5/6/09 a APPLICANT JURISDICTION City of Carlsbad a PLAN REVIEWER a FILE PLAN CHECK NO 09-0700 SET I PROJECT ADDRESS 1923 Calle Barcelona PROJECT NAME Nubonau - TI The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficiencies identified below are resolved and checked by building department staff The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck XJ The check list transmitted herewith is for your information The plans are being held at Esgil Corporation until corrected plans are submitted for recheck The applicant's copy of the check list is enclosed for the jurisdiction to forward to the applicant contact person XJ The applicant's copy of the check list has been sent to Studio C / Mark Swenson 6125 Cornerstone Ct Suite 200, San Diego, CA 92121 Esgil Corporation staff did not advise the applicant that the plan check has been completed X] Esgil Corporation staff did advise the applicant that the plan check has been completed Person contacted Mark Swenson Telephone # 858-866-0889 Date contacted &/1/03 (by^W) Fax # 858-866-0868 Maily/Telephone Fay^ In Person REMARKS By Doug Moody [ Enclosures EsGil Corporation D GA D MB D EJ D PC 4/30/09 9320 Chesapeake Diivc, Suite 208 *• San Diego, California 92123 + (858)560-1468 * Fax (858) 560-1576 City of Carlsbad O9-O7OO 5/6/O9 PLAN REVIEW CORRECTION LIST TENANT IMPROVEMENTS PLAN CHECK NO 09-O70O OCCUPANCY M TYPE OF CONSTRUCTION VB ALLOWABLE FLOOR AREA SPRINKLERS'? YES REMARKS DATE PLANS RECEIVED BY JURISDICTION 4/28/09 DATE INITIAL PLAN REVIEW COMPLETED 5/6/09 JURISDICTION City of Carlsbad USE Retail ACTUAL AREA 892sf STORIES 1 HEIGHT OCCUPANT LOAD 22 DATE PLANS RECEIVED BY ESGIL CORPORATION 4/30/09 PLAN REVIEWER Doug Moody FOREWORD (PLEASE READ) This plan review is limited to the technical requirements contained in the International Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the disabled This plan review is based on regulations enforced by the Building Department You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department, Fire Department or other departments Clearance from those departments may be required prior to the issuance of a building permit Code sections cited are based on the 2007 CBC, which adopts the 2006 IBC The following items listed need clarification, modification or change All items must be satisfied before the plans will be in conformance with the cited codes and regulations Per Sec 105 4 of the 2006 International Building Code, the approval of the plans does not permit the violation of any state, county or city law To speed up the recheck process, please note on this list (or a copy) where each correction item has been addressed, i e . plan sheet number, specification section, etc Be sure to enclose the marked up list when you submit the revised plans City of Carlsbad O9-O7OO 5/6/09 Please make all corrections on the original tracings, as requested in the correction list Submit three sets of plans for commercial/industrial projects (two sets of plans for residential projects) For expeditious processing, corrected sets can be submitted in one of two ways 1 Deliver all corrected sets of plans and calculations/reports directly to the City of Carlsbad Building Department, 1635 Faraday Ave , Carlsbad, CA 92008, (760) 602-2700 The City will route the plans to EsGil Corporation and the Carlsbad Planning, Engineering and Fire Departments 2 Bring one corrected set of plans and calculations/reports to EsGil Corporation, 9320 Chesapeake Drive, Suite 208, San Diego, CA 92123, (858) 560-1468 Deliver all remaining sets of plans and calculations/reports directly to the City of Carlsbad Building Department for routing to their Planning, Engineering and Fire Departments NOTE Plans that are submitted directly to EsGil Corporation only will not be reviewed by the City Planning, Engineering and Fire Departments until review by EsGil Corporation is complete 1 When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy Please provide complete details to show the building will comply Section 3405 The previous use of the mezzanine was "unoccupied equipment platform not to be use for storage or any other purpose" per Carlsbad Building permit 04-4096 If the new tenant wishes to change the occupancy to storage complete calculations and details showing the mezzanine adequate for 125 PSF light storage and disabled access (elevator or platform lift) will be required 2 Please note in the general wiring notes on the plans "AC Cable is not allowed in A, B, E, H, F, M, S and I occupancies NM cable is restricted (without City approval) to one and two family dwellings Note on plans that an equipment ground conductor is to be installed in all flexible conduits" 3 Please provide the required LTG-9-C form for the track lighting 4 Provide complete energy designs for the proposed changes in the building envelope (storefront glazing) Provide the completed ENV- forms showing energy compliance 5 The completed and signed ENV-1forms must be imprinted on the plans 6 Per Section 1117B 9 the non-commercial kitchen sink shall provide the following a) A clear floor space at least 30"x 48" shall be provided for forward approach and shall be on an accessible route The clear space shall extend a maximum of 19" underneath the sink b) The accessible sink shall be a maximum of 6 1/2" deep The sink shall be mounted with the counter or rim no higher than 34" above finish floor City of Carlsbad 09-O700 5/6/O9 Knee clearance that is at least 27" high, 30" side and 19" underneath the sink shall be provided Hot water and dram shall be insulated or otherwise configured so as to protect against contact There shall be no sharp or abrasive surfaces under the sink c) Faucet controls and operating mechanisms shall be operable with one hand and shall not require tight grasping, pinching or twisting of the wrist Lever operated, push-type and electronically controlled mechanisms are acceptable Self-closing valves are allowed if the faucet remains open for at least 10 seconds To speed up the review process, note on this list (or a copy) where each correction item has been addressed, i e , plan sheet, note or detail number, calculation page, etc Please indicate here if any changes have been made to the plans that are not a result of corrections from this list If there are other changes, please briefly describe them and where they are located in the plans Have changes been made to the plans not resulting from this correction list? Please indicate Yes Q No a The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123, telephone number of 858/560-1468, to perform the plan review for your project If you have any questions regarding these plan review items, please contact Doug Moody at Esgil Corporation Thank you City of Carlsbad O9-O7OO 5/6/09 [DO NOT PAY- THIS IS NOT AN INVOICE] VALUATION AND PLAN CHECK FEE JURISDICTION City of Carlsbad PLAN CHECK NO O9-070O PREPARED BY Doug Moody DATE 5/6/09 BUILDING ADDRESS 1923 Calle Barcelona BUILDING OCCUPANCY M TYPE OF CONSTRUCTION VB BUILDING PORTION Tl Air Conditioning Fire Sprinklers TOTAL VALUE Jurisdiction Code AREA (Sq Ft) 892 cb Rlrln Permit Fee bv Ordinance ^ Valuation Multiplier 34 37 By Ordinance Reg Mod VALUE ($) 30,658 30,658 $271 11 Plan Check Fee by Ordinance i^J Type of Review G3 Complete Review Repetitive FeeRepeats D Other r-1 Hourly EsGil Fee Structural Only Hr @ $17622 $151 82 Comments Sheet 1 of 1 macvalue doc + PLANNING/ENGINEERING APPROVALS PERMIT NUMBER CB 09-0700 DATE 4/29/9 ADDRESS 1923 Calle Barcelona RESIDENTIAL ADDITION- MINOR (<17,000.00) RETAINING WALL VILLAGE FAIRE POOL/SPA TENANT IMPROVEMENT COMPLETE OFFICE BUILDING OTHER Tl - The Forum PLANNER Chris Sexton ENGINE DATE 4/29/9 DATE II \AI).MIN\C(ll NlHI/lt\N.\l\G/EX(;i»;ill.\r, AITIIOVAI.S Carlsbad Fire Department Plan Review Requirements Category TI, COMM Date of Report 05-29-2009 MARK SWENSON Reviewed by Name Address STE 200 6125 CORNERSTONE CT SAN DIEGO CA 92121 Permit # CB090700 Job Name NUBONAU- 892 SF TI-STOREFRONT, Job Address 1923 CALLE BARCELONA CD AD St 147 The item you have submitted for review is incomplete At this time, this office cannot adequately conduct a review to determui£^Hjjii3*aH^^ review carefully all pnmmpn||s_aitaw=Trn'''''lj'fea'se resuhrmi the necessary plans and/or specifications. wnTFenanges" "clouded", Conditions: Cond CON0003487 [MET] **APPROVED THIS PROJECT HAS BEEN REVIEWED AND APPROVED FOR THE PURPOSES OF ISSUEANCE OF A BUILDING PERMIT THIS APPROVAL IS SUBJECT TO FIELD INSPECTIONS. ANY REQUIRED TESTS, FIRE DEPARTMENT NOTATIONS, CONDITIONS IN CORRESPONDENCE AND COMPLIANCE WITH ALL APPLICABLE CODES AND REGULATIONS THIS APPROVAL SHALL NOT BE HELD TO PERMIT OR APPROVE ANY VIOLATION OF THE LAW Entry 05/29/2009 By cwong Action AP TITLE 24 REPORT Title 24 Report for: Nubo-Nau 1923 Calle Barcelona, Suite 147 Carlsbad, CA 92009 Project Designer- Studio C Architects 6125 Cornerstone Ct E , Suite 200 San Diego, CA 92121 (858) 866-0889 Report Prepared By: Lynn Kramer, P E Kramer Engineering Services 4901 Morena Blvd Suite 905 San Diego, CA92117 (858) 274-9860 Job Number: Nubol Date: 5/11/2009 The EnergyPro computer program has been used to perform the calculations summarized in this compliance report This program has approval and is authorized by the California Energy Commission for use with both the Residential and Nonresidential 2005 Building Energy Efficiency Standards This program developed by EnergySoft, LLC - www energysoft com EnergyPro 4 4 byEnergySoft Job Number Nubol User Number 5196 76O TABLE OF CONTENTS Cover Page 1 Table of Contents 2 Form ENV-1-C Certificate of Compliance 3 Form ENV-3-C Overall Envelope Method 5 Form ENV-4-C Skylight Fraction of Dayht Area 12 Form ENV-4-C Skylight Effective Apperture 13 Form ENV-MM Envelope Mandatory Measures 14 Zone Load Summary 15 Room Load Summary 16 Room Heating Peak Loads 17 Room Cooling Peak Loads 20 EnergyPro 4 4 by EnergySofl Job Number Nubol User Number 5196 CERTIFICATE OF COMPLIANCE (Parti of2) ENV-1-C PROJECT NAME Nubo-Nau PROJECT ADDRESS 1923 Calle Barcelona, Suite 147 Carlsbad PRINCIPAL DESIGNER - ENVELOPE Studio C Architects DOCUMENTATION AUTHOR Kramer Engineering Services TELEPHONE (858) 866-0889 TELEPHONE (858) 274-9860 DATE 5/11/2009 Building Permit # Checked by/Date Enforcement Agency Use GENERAL INFORMATION DATE OF PLANS 4/22/09 BUILDING CONDITIONED FLOOR AREA 1,233SqFt CLIMATE ZONE BUILDING TYPE NONRESIDENTIAL RELOCATABLE- Indicate HIGH RISE RESIDENTIAL Specific Climate - list _, or HOTEL/MOTEL GUEST ROOM All Climates PHASE OF CONSTRUCTION NEW CONSTRUCTION ADDITION ALTERATION UNCONDITIONED (File Affidavit) METHOD OF ENVELOPE COMPLIANCE COMPONENT (ENV-2-C) [X] OVERALL ENVELOPE (ENV-3-C) f~] PERFORMANCE STATEMENT OF COMPLIANCE This Certificate of Compliance lists the building features and performance specifications needed to comply with Title 24, Parts 1 and 6 of the California Code of Regulations This certificate applies only to building envelope requirements The documentation preparer hereby certifies that the document is accurate and complete DOCUMENTATION AUTHOR Lynn Kramer. P E SIGNATURE DATE The Principal Envelope Designer hereby certifies that the propose^mlifding design represented in this set of construction documents is consistent with the other compliance forms and worksheets, with the specifications, and with any other calculations submitted with this permit application The proposed building has been designed to meet the envelope requirements contained in Sections 110, 116 through 118, and 140, 142, 143 or 149 of Title 24, Part 6 Please check one I hereby affirm that I am eligible under the provisions of Division 3 of the Business and Professions Code to sign this document as the person responsible for its preparation, and that I am licensed in the state of California as a civil engineer or mechanical engineer, or I am a licensed architect | | I affirm that I am eligible under the exemption to Division 3 of the Business and Professions Code by Section 5537 2 or 6737 3 to sign this document as the person responsible for its preparation, and that I am a licensed contractor performing this work | | I affirm that I am eligible under Division 3 of the Business and Professions Code to sign this document because it pertains to a structure or type of work described as exempt pujsuant to/business and Professions Code Sections 5537, 5538, and 67371 PRINCIPAL ENVELOPE DESIGNER - NAME Studio C Architects ENVELOPE MANDATORY MEASURES Indicate location on plans of Note Block for Mandatory Measures ENVELOPE COMPLIANCE FORMS & WORKSHEETS (Check box if worksheet is included) For detailed instructions on the use of this and all Energy Efficiency Standards compliance forms, please refer to the Nonresidential Manual published by the California Energy Commission K1ENV-1-C Certificate of Compliance Required on plans for all submittals Part 2 may be incorporated in schedules on plans DENV-2-C Used Envelope Component compliance method EENV-3-C Used with Overall Envelope Compliance method KlENV-4-C Optional Use for minimum skylight requirements for large enclosed spaces EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 3 of 22 CERTIFICATE OF COMPLIANCE (Part 2 of 2) ENV-1-C PROJECT NAME Nubo-Nau DATE"5/11/2009 IQPAQUE SURFACES # "T 2 3 4 5 Surface Type Roof Wall Wall Roof ' Insulation Area U-Fac Cav Cont 733 0 051 23S 0 102 1341 0102 250| 0 051 Wall 134| 0 102 I I | R-19! R-00 R-13! R-00 R-131 R-00 R-19 R-13 '' i i I i i I ! .\I R-00 R-00 Act Azm ' Tilt 0 270 0 90 90 i 90 rcond*! Status Existing Existing Joint Appendix IV Reference I Location / Comments ( 02-A5 Sales i 09-A3 Sales Existing I09-A3 ; Office 0 i 0 Existing J02-A5 Mezzanine 90 90 . Existing 09-A3 ] I ' ! I i ' 1 ! !I i 1 i j I i: : ' Mezzanine | I i •N E A R (New Existing Altered Removed) IFENESTRATION SURFACES I More than or equal to 10 000 sq ft. of site-built fenestration area must include a label certificate either issued by NFRC or provide a CEC Default Label Certificate using the default U factors from i Standards Table 116 A and B Certificate shall be filed in the contractor's project office during construction and in the building manager's office after construction # 'Type 1 'Window Front (W) 2 IWmdow Front (W) 3 Window Front (W) 4 Window Front (W) Area 14 26 U-Fac1 I Act ! Cond SHGC2 i Azm ! Stat 0290lNFRC| 038 I COGi 270I New 0290 52| 0 290 NFRC NFRC 28i 0290, NFRC I . i. ' 1 I I 1.!._. _ . _. ._ ' I 038 038j 038 i i COG COG COG I 270 1 New 270, New 270! New ! Glazing Type PPG SOLARBAN 60 (2) Clear PPG SOLARBAN 60 (2) Clear PPG SOLARBAN 60 (2) Clear PPG SOLARBAN 60 (2) Clear i i Location/ Comments Sales Sales Sales Sales I (1)U factor Type 116 A Default Table from Standards Table NI-1 Default Table from the ACM Manual Appendix NFRC Labeled value (2) SHGC Type 116-B Default Table from Standards COG Center of Glass NFRC Labeled Value I EXTERIOR SHADING 1 # 1 2 3 4 Exterior Shade Type None None None None SHGC 076 076 076 076 Window Hgt Wd Overhang Len Hgt LExtRExt Left Fin ' Right Fin Dist Len Hgt ' Dist Len Hat i i , i iI j I MINIMUM SKYLIGHT AREA FOR LARGE ENCLOSED SPACES The proposed building Is In climate zones 2 through 16 and contains an enclosed space with floor area greater than 25,000 R2, a celling height greater than 15 feet, and an LPD for general lighting of at least 0 5 W/R2 See Section 143(c) If this box Is checked ENV-4-C must be filled out when submitting under the Prescriptive Compliance Approach EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 4 of 22 OVERALL ENVELOPE METHOD (Parti of7) ENV-3-C PROJECT NAME DATE Nubo-Nau 5/11/2009 i IWINDOW AREA CALCULATION A DISPLAY PERIMETER B GROSS EXTERIOR WALL AREA C ENTER LARGER OF A OR B D ENTER PROPOSED WINDOW AREA 0 ftx6ft = 623 ft x 040 = 0 ft2 DISPLAY AREA 249 i ft2 40% GROSS WALL AREA 623 249 ft2 MAXIMUM STND AREA E WINDOW WALL RATIO = Proposed Window Area Divided by Gross Exterior Wall Area = 120 ft2 PROPOSED AREA 1926%! 0 ftx6ft = 355 ft x o 40 = F WEST DISPLAY PERIMETER G WEST EXTERIOR WALL AREA H ENTER THE LARGER OF F AND G I ENTER PROPOSED WEST WINDOW AREA J WEST WINDOW WALL RATIO = Proposed West Window Area Divided by West Exterior Wall Area = 0 ft2 WEST DISPLAY AREA 142 ft 40% WEST WALL AREA 355 142 ft2 MAX STND WEST AREA 120J ft2 PROPOSED WEST AREA Combined Values for North East and South Walls K N/E/S DISPLAY PERIMETER (A - F) | L N/E/S EXTERIOR WALL AREA (B - G) M ENTER LARGER OF K OR L N PROPOSED N/E/S WINDOW AREA (D I) Oj ftx6ft =0 ft2 N/E/S DISPLAY AREA 268: ftx 040 = 268 107 ft 40% N/E/S AREA 1Q7| ft2 MAX STAND N/E/S AREA 0 ft PROPOSED N/E/S AREA WINDOW ADJUSTMENT 0 IF D > C and/or if I > H, PROCEED TO CALCULATION STEPS 1 OR 2, AS APPROPRIATE, FOR THE WINDOW AREA ADJUSTMENT IF NOT, GO TO THE SKYLIGHT AREA TEST, ENV-3 C, PART 2 OF 7 1 IF l< H Use the calculated Window adjustment for all walls MAXIMUM STANDARD PROPOSED WINDOW AREA (from C) AREA (from D) WINDOW ADJUSTMENT FACTOR 2 IF I > H Calculate one window adjustment factor (WAF) for the West wall a Calculate the WAF for the West wall MAX STANDARD WEST PROPOSED WEST AREAJfrom HI AREA (from I) WEST WINDOW ADJUSTMENT FACTOR b If N > M Calculate the WAF for the North East and South walls j MAX STANDARD N/E/S AREA (from M) PROPOSED N/E/S AREA (from N)• •• ••• N/E/S WINDOW ADJUSTMENT FACTOR: ! GO TO PART 7 TO CALCULATE ADJUSTED AREAS EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 5 of 22 (OVERALL ENVELOPE METHOD (Part 2 of 7) ENV-S-C ! PROJECT NAME DATE j Nubo-Nau 5/11/2009 I SKYLIGHT AREA TEST A ATRIUM HEK B IF <= 55 FT C IF > 55 FT D IF THE PROF TO THE NEX 1 IF PROPOSE! I EnergyPro 4 4 3HT 15 ft GROSS STANDARD ALLOWED ROOF AREA SKYLIGHT AREA 983 ft2xoos= 49 ft2 ft:x010= ft2 PROPOSED SKYLIGHT AREA fj| ^ >OSED SKYLIGHT AREA IS GREATER THAN THE STANDARD SKYLIGHT AREA, PROCEED T CALCULATION FOR THE SKYLIGHT AREA ADJUSTMENT IF NOT, GO TO PART 3 OF 7 3 SKYLIGHT AREA >= STANDARD SKYLIGHT AREA PROPOSED SKYLIGHT AREA SKYLIGHT STANDARD SKYLIGHT AREA (IF E = 0 ENTER 1 ) ADJUSTMENT FACTOR » ^^ GO TO PART 7 TO CALCULATE ADJUSTED AREAS byEnergySoft User Number 5196 Job Number Nubol Page 6 of 22 OVERALL ENVELOPE METHOD (Part 3 of 7) ENV-3-C PROJECT NAME DATE Nubo-Nau 5/11/2009 OVERALL HEAT LOSS A ASSEMBLY NAME (eg Wall-1,Floor-1) Roof West Wall Small Window Medium Window Large Window Glass Door East Wall Roof East Wall B C D E PROPOSED AREA 733 235 14 26 52 28 134 250 134 HEAT CAP U- FACT1 0051 0102 0290 0290 0290 0290 0102 0051 0102 ACM J A IV Ref 02-A5 09-A3 09-A3 02-A5 09-A3 1 ) In climate zones 1 and 1 6 the insulating R value of continuous *|f window and/or Skylight Area Adjustment is insulation materials installed above the roof waterproof Required use Adjusted Areas from Part 7 of 7membrane shall be multiplied times 0 8 before choosing thetable column for determining assebmly U factor See Footnotes Tables IV 1 through IV 7 in the Joint Appendices UA (BXD) 374 240 41 75 151 81 137 128 137 136 136 F | G H STANDARD AREA* (Adjusted) 733 235 14 26 52 28 134 250 134 U- FACT 0076 0110 0770 0770 0770 0770 0110 0076 0110 UA (FXG) 557 259 108 200 400 216 147 190 147 j This Page Total Building Total 222 222 EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 7 of 22 OVERALL ENVELOPE METHOD (Part 4 of 7) ENV-3-C PROJECT NAME Nubo-Nau DATE 5/11/2009 (OVERALL HEAT GAIN FROM CONDUCTION 1 A! ASSEMBLY NAME (eg Wall-1, Floor 1) Roof B I AREA 733 West Wall | 235 L<L TF 27 27 GP_._ HEAT CAP E F PROPOSED U ACM FACT JA IVRef HEAT GAIN (BxCxE) 0 051 02-A5 1 009 0102 09-A3 Small Window 14 27 0290! l|Medium Window ! 26 27 ! | Large Window I Glass Door East Wall Roof East Wall ! I I ; I 52 28 134 250 27 27 27 27 134, 27 0290 0290 0290 0102 0051 0102 j ; 09-A3 02-A5 647 110 204 407 219 369 G H 1 STANDARD AREA* (Adjusted) 733 235 | 14 26 52 U- FACT 0076 0110 TF J HEAT GAIN (GxHxl) 27 1 504 ' 27 0770 27 0770 0770 28 | 0 770 134 344 250 09-A3 , 369 134 ! 1 1! 0110 0076 0110 1) In climate zones 1 and 16 the insulating R value of continuous !f Window and/or Skylight Area Adjustment is insulation materials installed above the roof waterproof membrane Required use Adjusted Areas from Part 6 of 7 'shall be multiplied times 0 8 before choosing the table column for ; determining assembly U factor See footnotes Tables IV 1 through IV 7 in the Joint Appendices 27 27 698 291 541 1081 27 582 27 ' 398 27 513 27 398 ; 1 i 3678 Subtotal 6,006 Subtotal EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 8 of 22 (Part 5 of 7) ENV-3-C PROJECT NAME Nubo-Nau IDATE 5/11/2009 ROOF ABSORPTANCE CALCULATION R-1 9 Roof Cathedral CHECK APPLICABLE BOXES : Case 1 - Proposed YES NO i 1 CRRC-1 Certified? 2 Is the thermal emittance > 0 75? 3 Enter the initial reflectance PM value 4 Calculate a pro = 094-0 ?PRI prop | { Go to 2 | Go to 3 Go to 8 Go to 5 Go to 4 Insert value in calculation Enter calculated value in Column F below Case 2 - CRRC-1 Tested 5 Enter initial reflectance & emittance values from CRRC 1 ! 6 Calculate p» pmp = - 0 448 + 1 121 p« + 0 524 E» |7 Calculate a P»P = 094 i a prop •— B« = |Em = I Go to 6 Insert values in calculation Go to 7 Insert value in calculation Enter calculated value in Column F below 8 Not CRRC-1 Tested For nonresidential low-sloped roofs For all other roofs 0 87; Enter default value in Column F below 073. Enter default value in Column F below Standard absorptance values for Column J are either For nonresidential low sloped roofs 3 std 0 45 Enter standard value in Column J below A ASSEMBLY NAME (eg Roof-1) Roof Roof Check If nonreslow-sloped roofX X 1 B ic i D f E F G PROPOSED AREA 733 25Q_ SF 123 WF 087 123 i 087 u FACTOR 0051 0.051 Absorp 087 _as7_ HEAT GAIN (BxCxDxExF) 3.480 1,187 H 1 ' J K STANDARD AREA* (ADJUSTED) 733 250 U-Factor 0076 0.076 HEAT GAIN Absorp (CxDxHxIxJ) 1 045 i 2.683i 0.45 i 915 1 1 i i i I , 1 4,667 Subtotals are entered under Subtotal SUBTOTAL in COLUMNS I and M of ENV 3 C Part 6 of 7 _. 3,59811 SUBTOTAL EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 9 of 22 OVERALL ENVELOPE METHOD (Part 6 of 7) ENV-3-C PROJECT NAME Nubo-Nau DATE 5/11/2009 [OVERALL HEAT GAIN FROM RADIATION FENESTRATION SURFACES win i Small Window i Medium Window •Large Window Glass Door A KYLIGHT NAME , Sky 1) ORIENT B C WEIGHTINGFACTOR ow W ! 1 17 ndow W > 1 17 ow w 1 17 W 1 17 AREA 14 26 52 28 D E F G H 1 I J PROPOSED 1 , OVERHANG SF SHGC" H "' v :H/vToHF 123 123 123 123 041i 041 041 0.41 ! ! I i '1 j 1 j { j i i K L M STANDARD HEAT GAIN2 ! AREA 3(BxCxDxExH) | (ADJUSTED) 820 1,522 3044 1639 I 14 26 RSHG 4or SHGC4 061 061 52 061 28 SF HEAT GAIN(BxJxKxL) 1231 1,229 123 123 061:123 2282 4,565 2,458 I j | i I i Ij ; i ii i' 1 1! 1 1 1 From Fenestration Surfaces ENV 1 C Part 2 Column G or when Column H has a C identifier calculate using the center of glass value SHGCc in SHGCfen = 08 + (0 86xSHGCc) and enter value 2 Proposed Heat Gam Column I may be no greater than Standard Heat Gam Column M 3 If Window and/or Skylight Area Adjustment is required use adjusted area from Part 6 of 7 4 Only SHGC is used for Skylights Part 4 Subtotal Part 5 Subtotal Part 6 Subtotal 3678J _4667J 7025 15,37-j Part 4 Subtotal Part 5 Subtotal Part 6 Subtotal Total Heat Gain 6_006J 3598J 10534! 20,1381 EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol _Page 10 of 22 | OVERALL ENVELOPE METHOD (Part 7 of 7) ENV-3-C| PROJECT NAME Nubo-Nau DATE 5/11/2009 WINDOW AREA ADJUSTMENT CALCULATIONS [X] CHECK IF NOT APPLICABLE (See Part 1 A WALL NAME (eg Wall-1,Wall-2) of?) r ORIENTATION N [ [ nD D D D D [ [ [ [ DDnD E D Dnnnn n s n n nnnnnn LJ n nn nn nnn nn nn W D n Dnnn nn Dnnnnn TOTALS D GROSS AREA C DOOR AREA D WINDOW AREA E WINDOW ADJUST FACTOR (From Parti) N/A F ADJUSTED WINDOW AREA (DXE) G ADJUSTED WALL AREA B - (F + C) ISKYLIGHT AREA ADJUSTMENT CALCULATIONS [Xl CHECK IF NOT APPLICABLE (See Part 2 of 7) A ROOF NAME (e g Roof-1 , Roof-2) TOTALS B GROSS AREA C SKYLIGHT AREA D SKYLIGHT ADJUST FACTOR (From Parti) N/A E ADJUSTED SKYLIGHT AREA (CXD) F ADJUSTED ROOF AREA (B-E) EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 11 of 22 ENVELOPE COMPLIANCE (Parti of2) ENV-4-C PROJECT NAME Nubo-Nau DATE 5/11/2009 SKYLIGHT AREA SUPPORT WORKSHEET - Minimum Fraction of Davht Area Method SKYLIGHT AREA FOR LARGE ENCLOSED SPACES This worksheet applies to buildings with an enclosed space > 25,000 ft2 with a ceiling height >15 ft and an LPD for the space for general hghting>05W/ft2 A Enter proposed daylit area as indicated on plans Proposed daylit area is indicated on page of the plans B Floor Area 0) ft2 x 050 = D Criterion 1 Proposed Daylit Area is equal to or greater than Minimum Daylit Area C Select the appropriate box based on the LPD in W/ft2 D LPD > 1 4 D 1 0 < LPD < 1 4 H 0 5 < LPD <1 0 Enter36%-> Enter33%-> Enter30%-> D Minimum skylight area Enter the product BxC then divide by 100 E Enter the proposed total skylight area in the large enclosed space D Criterion 2 Proposed skylight area is equal to or greaterthan minimum skylight area ~\ Criterion 3 Haze rating of skylight glazing or skylight diffuser is greater than 90% Document and page number wit haze specification of skylight D Large enclosed space complies with Criteria 1, 2, and 3 above [Sections 143(C)1, 2, and 3] Proposed Daylit Area Minimum Dalit Area 30 Skylight-Daylit Fraction Q! Minimum Skylight Area Proposed Skylight Area EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubot Page 12 of 22 ENVELOPE COMPLIANCE (Part 2 of 2) ENV-4-C PROJECT NAME Nubo-Nau DATE 5/11/2009 I SKYLIGHT AREA SUPPORT WORKSHEET - Minimum Effective Aperture Method SKYLIGHT AREA FOR LARGE ENCLOSED SPACES This worksheet applies to buildings with an enclosed space > 25,000 ft with a ceiling height >15 ft and an LPD for the space for general lighting > 0 5 W/ft _ f F Enter proposed daylit area as indicated on plans Proposed daylit area is indicated on page of the plans G Floor Area 0 ft2 x 050 = Proposed Daylit Area 0 Minimum Dalit Area D Criterion 1 Proposed Daylit Area is equal to or greater than Minimum Daylit Area H Select the appropriate box based on the LPD in W/ft 2 D LPD > 1 4 Enter 1 2% - D 1 0 < LPD < 1 4 Enter 1 1%-> I 0 5 < LPD <1 0 Enter 1 0% ->r~1 0 Mm Effective Aperture I VLT.I Skylight Visible Light Transmittance (VLT ) VLT. is from manufacturers specifications J Well Cavity Ratio Select one of the well types fill in columns A B C and Calculate the WCR with the appropriate equation below A Well Height B Well Length C Well Width WCR = 5 x well height (well length + well width)_ well length x well width A _ Effective Aperture (H) x Daylit Area (F) s 0 85 x VLT (I) x WellEfficiency (L) N Enter the Proposed Skylight Area J WCR Well Height Well Perimeter Well Area , WCR = (2 5 x well height x well perimeter) / well area K Average Well Wall Reflectance (%) p L Well Efficiency (from equation) M Calculate Minimum Skvhqht Area ! WCR ! , Well p Well Efficiency DCriterion 2 Proposed skylight area is equal to or greater than minimum skylight area DCriterion 3 Haze rating of skylight glazing or skylight diffuser is greater than 90% Document and page number wit haze specification of skylight D Large enclosed space complies with Criteria 1, 2, and 3 above [Sections 143(C)1, 2, and 3] EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 13 of 22 ENVELOPE MANDATORY MEASURES ENV-MMl PROJECT NAME Nubo-Nau DATE 5/11/2009 DESCRIPTION [XJ § 118(a) Installed Insulating Material shall have been certified by the manufacturer to comply with the California Quality Standards for insulating material, Title 20, Chapter 4, Article 3 i |X| § 118(c) All Insulating Materials shall be installed in compliance with the flame spread rating and smoke density requirements of Sections 2602 and 707 of Title 24, Part 2 |X| §117(a) All Exterior Joints and openings in the building that are observable sources of air leakage shall be caulked, gasketed, weatherstnpped or otherwise sealed [X] § 116(b) Site Constructed Doors, Windows and Skylights shall be caulked between the unit and the building, and shall be weatherstnpped (except for unframed glass doors and fire doors) | | § 116(a)1 Manufactured Doors and Windows installed shall have air infiltration rates not exceeding those shown in Table Number 1-E of the Standards Manufactured fenestration products must be labeled for U-value according to NFRC procedures [X] § 118(e) Demising Walls in Nonresidential Buildings The opaque portions of framed demising walls in nonresidential buildings shall have insulation with an installed R-value of no less than R-13 between framing members Designer Enforcement EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 14 of 22 ROOM HEATING PEAK LOADS Project Title Date Nubo-Nau 15/11/2009 Room Information Design Conditions Room Name Sales Time of Peak Jan 12 am Floor Area 733 Outdoor Dry Bulb Temperature 34 °F Indoor Dry Bulb Temperature 70 °F Conduction Area U-Value AT°F Btu/hr R-1 9 Roof Cathedral 7330 X 00510 x 36 = 1346 Slab-On-Grade perimeter =16 9 X 07300 x 36 = 444^ R-13Wall 2350 X 01020: X 36 = 863 PPG SOLARBAN 60 (2) Clear 140 X 02900 PPG SOLARBAN 60 (2) Clear i 260 x 02900 PPG SOLARBAN 60 (2) Clear : 52 0 X 0 2900 PPG SOLARBAN 60 (2) Clear 280 X 02900 ! x x ! _ X | x . X i X X ' XI i X X 36 = 146 X 36j = 271 X 36: = 543 X 36 = 292i X = X = X | = . x = ; X = ' X : = I X i = ! i I ! !X ! = ' X = i : X X : ' = x x ! = X X ' I = h v v -X : X ; —I"- I X ; x X X i X i XIi X X = I I X = i x : = i x . . = I x = : X = j X = X = i X I X = :• . ' i i x i X = X X = X X = X X = x I x = ! i X i X : = X X X X X = X = X = I X = Items shown with an asterisk ( ) denote conduction through an interior surface to another room Panp Total " "„ „„! Infiltration 1 oo x : 1 078 x 733 x i 14 70; x o soo / 60 'Schedule Air Sensible Area Ceiling Height ACH Fraction X I 36 = 2,091 AT TOTAL HOURLY HEAT LOSS FOR ROOM 5 997 EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 17 of 22 ROOM HEATING PEAK LOADS Project Title Nubo-Nau iRoom Information Design Conditions Room Name Office Time of Peak Floor Area 250 Outdoor Dry Bulb Temperature Indoor Dry Bulb Temperature 70 °F Date 5/11/2009 I Jan 12 am 34 °F Conduction Area U-Value AT°F Btu/hr Slab-On Grade | perimeter = 169 X i 07300 1 x FMSWall 1340 X 01020 xr ~ " •- " - '. ... x x ! X X X i X X i X x ; x x x X : X X X ; * v * X ' X X X X X X x X i X X ! x x i X i IT"" ~ x I J ! x X X X X , XX ! ,...__... ! X X i X X i X : X X X X X i X Y : I x : X ' ! x x : X X i X X X I X : X X X X 36 1 = I 444 36 = 492 = .i | ™ ; = l = =_ _ = = ; _ _ — = = i i — i_ _ ™ j =- ! _ — - n I _I = _ j : = =_ _ ; ™ = _ | = I = X X = x ! x X : X — = Items shown with an asterisk (*) denote conduction through an interior surface to another room Paap Total Infiltration : looix 1 078 x 2solx' soolxl 0300 /60j x I ^Schedule Air Sensible Area Ceiling Height ACH AT Fraction TOTAL HOURLY HEAT LOSS FOR ROOM 36' = 388: 1324J EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 18 of 22 ROOM HEATING PEAK LOADS Project Title Nubo-Nau Date ;5/11/2009 Room Information Design Conditions Room Name Mezzanine : Time of Peak Jan 1 2 am Floor Area 250 Outdoor Dry Bulb Temperature 34 °F Indoor Dry Bulb Temperature 70°F. ! Conduction Area U-Value I R-1 9 Roof Cathedral 250 0 X lR-13Wall i 1340 X X X X X X : x i x X X X X X X : X - . • X X X X X X x : x X x : x x : y ! x X ; x x ! X X x ; X ; X Items shown with an asterisk (*) denote conduction through an interior surface to another room 00510 x 01020! x : x X X x X X X i X x X i X X x X X X X X x ! X X X X X X X ! x x X . .._...] x X X X X X X X Infiltration 1 oo x 1 ors x 250 x 800;x| osoo /60 x Schedule Air Sensible Area Ceiling Height ACH Fraction TOTAL HOURLY HEAT LOSS FOR ROOM AT°F 36 36 \ - . - = = = = = = = Page Total se! AT ! Btu/hr 459^ 492, i , !h "1 I 951 388 ; 1339 | EnergyPro 44 byEnergySoft User Number 5196 Job Number Nubol Page 19 of 22 ROOM COOLING PEAK LOADS i Project Title 1 Nubo-Nau ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction R-1 9 Roof Cathedral [M3 Wall PPG SOLARBAN 60 (2) Clear PPG SOLARBAN 60 (2) Clear PPG SOLARBAN 60 (2) Clear PPG SOLARBAN 60 (2) Clear Date DESIGN CONDITIONS Sales Time of Peak 733 Outdoor Dry Bulb Temperature 74°F Outdoor Wet Bulb Temperature Area U-Value DETD 7330 X 00510 X 2 | 2350 X 01020; X j 3 140 X 02900 X 26 Q: X : 02900 X 520 X 02900! X 28 ol X 02900 X I X X X IX • i X i X : 1 Design Equivalent Temperature Difference (DETD) Page Items shown with an asterisk (') denote conduction through an interior surface to another room WeiglSolar Gam Orientation Area SGF SC Fac Small Window . (W) 14 Oj X 238 X . 0453 X 0; Medium Window (V Large Window (W Glass Door (W I Sched Internal Gain Frac Area Lights 1 00;x; 733 > Dccupants 1 00 X 733 > Receptacle | | 1 00 x 733 > 3rocess ! 1 OO1 X 733 > — Infiltration ||_ 1 QQi x 107Schedule AirSensib Fraction /) : 260 1 X ! 238 X 0453 X 0! /) I 52ol X 238: X | 0453! X ' 0! /) 28 0 x i 238 X i 0453; x OJ : X X X x x x ' : | x : x j xh..._ : X X I i Y j X i X • X ! x I I x -x Page Weigl Heat Gam Fac i • 5/11/2009 Jul 5pm 82 "V 67 °F 1 Btu/hr 90j = 1083 31 = 794 61 = ^ 25: 61 = 46! 61 = 92 61 = 50 = _ Total 2,089 itmg tor Btu/hr 514] =[_ 775] ,14 = \ 1.4391 514 = 2879 514 = : 1,550 = L iH= [I — - 1 I= i I Total :_ 6,643j Jo'?9 Btu/hr c 1700 Watts/sqft x 3 41 3' Btuh/Watt x '• 0999 = ,_ 4249| c 250! Btuh/occ / ' 30 sqft/occ x 1 c 10001 Watts/sqft x 3413! Btuh/Watt x 1 c ooool Watts/sqft xj 3 413) Btuh/Watt x I 1 —I ! i II '8l X 733 j X I 1470: X ' 030! / 60 X i le Area Ceiling Height ACH -1 AT TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM Sched Latent Gam Frac Area Heat Gami i Occupants 1 00 : X .733 x 200! Btuh/occ / 30 saft/occ Beceptacle 1.00 X I 733 X^ 0.000 Watts/soft X : 3.413J Btuh/Watt Process 1 00 X | Infiltration i! 1.00 x 4^ -Schedule Air Late Fraction 733 i x o oooi Watts/sqft x i 3413 Btuh/Watt — 34^ X . 733 X 14.70 X j 0.30: / 60 X 0.00 nt Area Ceiling Height ACH -< ZM/V TOTAL HOURLY LATENT HEAT GAIN FOR ROOM EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol OOJ = 6047 OOJ = | 2502— I i ••00 = L Oj _9j = 523 22053 Btu/hr = 4,838 = |- o= I o 213 = 555 i 5.393 Page 20 of 22 ROOM COOLING PEAK LOADS Project Title Nubo-Nau Date 5/11/2009 ROOM INFORMATION Room Name Floor Area Indoor Dry Bulb Temperature Conduction A R-13Wall I I |_ I! I DESIGN CONDITIONS Office Time of Peak 250 Outdoor Dry Bulb Temperature 74% , Outdoor Wet Bulb Temperature rea U-Value DETD 1340 X | 01020 X : 2 X I X X ! X X X X | X x I x j X i X ! I X .X I x ! I x I Jul Sam 75* 65% 1 Btu/hr 8ll = | 385 = ' I = ,•~ = r ,= = ; = I I = 1 Design Equivalent Temperature Difference (DETD) Items shown with an asterisk ( ) denote conduction through an interior surface to another room Solar Gam Orientation Area SGF Page Total Weighting Factor 3851 Btu/hr Page Total Sched Internal Gam Frac Area Heat Gam Lights | pccupants Receptacle , Process I Infiltratioi 1 ooj x i 250 x | o ooo i Watts/sqft x 100JX 250 X 250J Btuh/OCC / 100V 250 x L 1500: Watts/sqft x iooix 250|x| 0000: Watts/sqft x . WeightingFactor Btu/hr 3413 Btuh/Watt x 100 sqft/occ x 3413 Btuh/Watt x 3413 Btuh/Watt x I ' I I I1 100: X 1078 X i 250 x 800 X I 030./60 X: Schedule Air Sensible Area Ceiling Height ACH -1 Fraction ITOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM i oooo = ! o 1 00: = 625 100, = ' 1280 i_ 1 oqj = i_ o 9 = ! 97 AT 2387 Latent Gam Occupants Receptacle _ Process Infiltration 1.001^Schedule Fraction Area Heat Gam 25QJ 25o] 250 200! Btuh/occ x OJJQO! Watts/sqft x x oooo Watts/sqft x 4,834Air Latent Area 25Q_ X _8.00.! X 100: sqft/OCC k13 Btuh/Watt 3413J Btuh/Watt Ceiling Height o.3ol /60, x ACH ->_0.002.1.8J = AW 106 I ITOTAL HOURLY LATENT HEAT GAIN FOR ROOM 606 I EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol I of 22 ROOM COOLING PEAK LOADS Project Title Nubo-Nau Date 5/11/2009 IROOM INFORMATION DESIGN CONDITIONS Room Name Floor Area {Indoor Dry Bulb Temperature Mezzanine Time of Peak 250 Outdoor Dry Bulb Temperature 74°F Outdoor Wet Bulb Temperature Conduction Area R-19 Roof Cathedral R-13Wall X X X X X X X X X U-Value 0 0510 01020 Jul 11 am 79^ 67 <t Btu/hr 66ll 282 1 Design Equivalent Temperature Difference (DETD) Items shown with an asterisk (*) denote conduction through an interior surface to another room Page Total 943 Weighting Solar Gam Orientation Area SGF SC Factor Btu/hr il I H ! j Sched Internal Gam Frac Area Lights 1 OOJ X 250 Occupants 1 oo! X 250 Receptacle ! I 1 00 x 250 Process 1 0Q X ; 250 r-- X X | X = X ; X : X = i : X X X = X I X I X = X X X . = X X X = X ! X ! X = X X X - i XX X = '! X ^ X i ;X • — '' Page Total j o1 Weighting Heat Gam Factor Btu/hr x! o ooo j Watts/sqft x 3413 Btuh/Watt x 0000 = o X 275J Btuh/OCC / 333 Sqft/OCC X 1 OOi = I 206 x 0200 Watts/sqft x 3 41 3J Btuh/Watt x 100= ml x oooo Watts/sqft x 3 41 3J Btuh/Watt x 100= o Infiltration II 1 oo x 1 07s| x : 250 x I 800 x I oso /60 x 9 1 = 97-LSchedule Air Sensible Area Ceiling Height ACH - AT Fraction TOTAL HOURLY SENSIBLE HEAT GAIN FOR ROOM 1 417 I Sched Latent Gam Frac Area Heat Gam Btu/hr Occupants 1 00 : X •Receptacle 1.00 x | Process 1 00 X | Infiltration ! LOO; x 4j Schedule Air Lab Fraction 250 X 475 Btuh/OCC / ! 333 Sqft/OCC = 356 250 x 0.000 Watts/sqft x 3.413 Btuh/Watt = o 250 x oooo Watts/sqft x 3413 Btuh/Watt = o ?34 X 250 X [ 8.00 1 X 0.30: / 60 Xi 0.00215 = 104jnt Area Ceiling Height ACH -1 AW TOTAL HOURLY LATENT HEAT GAIN FOR ROOM 460 EnergyPro 4 4 by EnergySoft User Number 5196 Job Number Nubol Page 22 of 22 CheckTa License or Home Improvement Salesperson (HIS) Registration - Contractors Stat Page 1 of 2 Department of Consumer Affairs Contractors State Li , e Board Contractor's License Detail - License # 928255 £lia DISCLAIMER A license status check provides information taken from the CSLB license database Before relying on this information, you should be aware of the following limitations • CSLB complaint disclosure is restricted by law (B&P 7124 6) If this entity is subject to public complaint disclosure a link for complaint disclosure will appear below Click on the link or button to obtain complaint and/or legal action information • Per B&P 7071 17 only construction related civil judgments reported to the CSLB are disclosed • Arbitrations are not listed unless the contractor fails to comply with the terms of the arbitration Due to workload there may be relevant information that has not yet been entered onto the Board's license database License Number Business Information Entity Issue Date Reissue Date Expire Date License Status Classifications Bonding 928255 Extract Date 06/01/2009 BINGHAM CONSTRUCTION COMPANY INC 10965 SAN DIEGO MISSION ROAD SAN DIEGO CA92108 Business Phone Number (619) 521-8588 Corporation 01/31/2009 05/28/2009 05/31/2011 This license is current and active All information below should be reviewed CLASS DESCRIPTION B GENERAL BUILDING CONTRACTOR CONTRACTOR S BOND This license filed Contractor's Bond number 105283436 in the amount of $12,500 with the bonding company TRAVELERS CASUALTY AND SURETY COMPANY OF AMERICA Effective Date 05/28/2009 Contractor's Bonding History BOND OF QUALIFYING INDIVIDUAL 1 The Responsible Managing Officer (RMO) JEFFREY CARVER BINGHAM certified that he/she owns 10 percent or more of the voting stock/equity of the corporation A bond of qualifying individual is not required Effective Date 05/28/2009 Vittrv: //w\vw9 rdh ra anv/DnlineServirps/rherkT icense/T icenseDetail asn 6/1/2009 a License or Home Improvement Salesperson (His; Kegisirauon - v^umidnuis ouu * This license has workers compensation insurance with the STATE COMPENSATION INSURANCE FUND Policy Number 1908307 Workers'Compensation ..-,.. ~ . „„,.. -,,„„„„Effective Date 04/17/2009 Expire Date 04/17/2010 Workers' Compensation History Miscellaneous, . DATE DESCRIPTIONInformation 05/28/2009 LICENSE REISSUED TO ANOTHER ENTITY Personnel List Conditions of Use | Privacy Policy Copyright © 2009 State of California https //www2 cslb ca gov/OnhneServices/CheckLicense/LicenseDetail asp 6/1/2009 NOT TRANSFERABLE BUS NUMBER 1228452 DATE ISSUED 5/7/2009 SIC CODE 1542 OWNER FIRM OR CORPORATION NAME BUSINESS NAME MAILING ADDRESS CITY AND STATE CITY OF CARLSBAD BUSINESS REGISTRATION CERTIFICATE Tha parson firm or corporation named Mow if granl«d In • Duain««a cart teate pursuant to tha provisions of lha City Busineia Leanae Ora nance* to angaga m, carry on or conduct lha businesa. Irada call ng profession. a»h b lion or occupatnn descr bad below lasuanca of Iha carl ficala la not an andoraamanl nor cart ficallon of compl anca win othar ord nancaa or laws TNs licansa la aauad wtlhout varification that lha licanaaa ta aubfact to or a amp* from Icarmng by lha Stole of Cat forma BUSINESS LOCATION 10965 SAN DIEGO MISSION RD SIC DESCRIPTION General Contractors-Nonresidential Buildings, ( EXPIRATION DATE 4/30/2010 BINGHAM CONSTRUCTION COMPANY, INC BINGHAM CONSTRUCTION COMPANY. INC 10965 SAN DIEGO MISSION RD SAN DIEGO CA 921082431 KEEP FOR YOUR RECORDS BUSINESS TAX RECEIPT BUS NO 1228452 DATE ISSUED 5/7/2009 08 070G $8000 BALANCE $000 TAXES PAID IN ACCORDANCE WITH CITY BUSINESS TAX ORDINANCE CITY OF CARLSBAD THIS DOCUMENT IS ALTERATION PROTECTED AND REFLECTS FLUORESCENT F1IERS UNDER UV LIGHT c; _s> en - ioi H O33m Tl 33 O H w Om O S1 o at •o n 2 2 §• o DO Forms/Feeso -A ^£ApprovedD n