2052 CORTE DEL NOGAL; B; CB891451; Permit
BUILDING PERMIT 12/11/89 08 31 Page 1 of 1 Job Address. 2052 CORTE DEL NOGAL Str. Permit Type COMMERCIAL TENANT IMPROVEMENT Parcel No 213-061-06-00 Valuation. 173,572 Construction Type. NEW ,., Occupancy Group. B-2 /.-' Class Code Description. CTI__20842 -SF & 7958 SF WAREHSE • SUITE B :-- Permit No. CB891451 Project No- A8902509 Development No• Fl: Ste-j- 02 C-PRilT 6G73-00 Status ISSUED Applied : 09/28/89 Apr/Issue • 12/11/89 Validated By JPY CONTRACTOR *** BRODW0LF 7811 MISSION GORGE RD STE L SAN DIEGO CA 92120 Fees Required *** *** Lie. C 423759 619 265-1801 Fees Collected & Credits * ** Fees: 7,976.00 Adjustments: .00 Total Fees: 7,976 00 Fee description Building Permit Plan Check Strong Motion Fee Enter 'Y' to Autocalc License Tax > * BUILDING TOTAL Enter "Y" for Plumbing Issue Fee > Each Plumbing Fixture or Trap > Each Water Heater and/or Vent > * PLUMBING TOTAL Enter "Y" for Electric Issue Fee > Three Phase Per AMP > * ELECTRICAL TOTAL ($10 Minimum) Enter 'Y' for Mechanical Issue Fee> Install Furn/Ducts > * MECHANICAL TOTAL Total Credits: Total Payments : Balance Due : Units Fee/Unit 3 . 00 2.50 1 00 2.50 600.00 50 6.00 9 00 1,103 6,873 00 00 00 Ext fee 899 584 26 . 6075 7584 7 7 2. 18 5 300 . 305 15 54. 69. 00 00 00 00 00 50 50 50 00 00 00 00 00 00 00 Data Y Y Y Y FINAL APPROVAL INSP. nMX' MTFf •/2 CLEAfWNCE CITY OF CARLSBAD 2075 Las Palmas Dr, Carlsbad CA 92009 (619) 438-1161 PERMIT APPLICATION City of Carlsbad Building Department 2075 Las Palmas Dr , Carlsbad, CA 92009 (BIS) 438- PERMIT TYPE QNEW [2KENANT IMPROVEMENTA ^COMMERCIAL B Q INDUSTRIAL G"EW QTENANT IMPROVEMENT c [^RESIDENTIAL DAPARTMENT QCONDO QSINGLE FAMILY DUELLING QDUPLEX DDEMOLITION ORELOCATION QMOBILE HOME QELECTRICAL OPLUMBING GMECHANICAL []POOL QSPA DRETAINING WALL DSOLAR QOTHER « / PROJECT INFORMATION PLAN CHECK No ^fTu/ding'or Suite No EST VAL_ PLM CK DEPOSIT VALID BY DATE yof, -^ 0174 09/28/89 0001 01 C-PRMT FOR OFFICE USE ONLY 0"" Address Nearest Cross Streets LEGAL DESCRIPTION /-^t p.-}- |g Subdivision Tame/N CHECK BELOU IF SUBMITTED ]2 Energy GatesD2 2 Structural Caics Soils Report Addressed Envelope ASSESSOR'S PARCEL 7/3-EXISTING USE PROPOSED USE DESCRIPTION OF WORK BLDG SO FTG # OF STORIES CONTACT PERSON CITY SIGNATURE f\0 STATE £^V ZIP CODE ^ ^ | £) g DAY TELEPHONE 4 APPLICANT NAME DCONTRACTOR n AGENT FOR CONTRACTOR ADDRESS STATF ZIP CODE nOWNER QAGENT FOR OWNER DAY TELEPHONE PROPERTY OWNER ADDRESS ZIP CODE DLESSEE DAY TELEPHONE ADDRESS STATE/^y^ ZIP CODE Vl\£*t=LO DAY TELEPHONE STATE LIC # 7. WORKERS' COMPENSATION Workers' Compensation Declaration I hereby affirm that 1 have a certificate of consent to self insure issued by the Director of Industrial Relations or a certificate of Workers' Compensation Insurance by an admitted insurer, or an exact copy or duplicate thereof certified by the Director of the insurer thereof filed with the Building Inspection Department (Section 3800 Lab C) t&7EXPIRATION DATEINSURANCE COMPANY /Q " / ' "T &CE COMPANY ^77/f/^ rf/fiJlS POLICY NO ^ ^-^^7 UN1! EXP1RAT1DH paTE f CJ ^ I / " Certificate of Exemption I certify that in the performance of the york for which this permit is issued, I shall not employ any person in any manner so as to become subject to the Workers' Compensation Laws of California SIGNATURE [~1 I, as owner of the property, am exclusively contracting with licensed contractors to construct the project (Sec 7Q44, Business and Professions Code The Contractor's License Law does not apply to an ownero-k^roperty who builds or improves thereon and contracts for such projects with contractor(s) licensed pursuant to the Contractor's License Law) I am exempt under Section Business and ProfessT ode for this reason (Sec 7031 5 Business and Professions Code Any City or County which requires a permit t^*7rwiiiX!^£5 • alter, improve, demolish or repair any structure prior to its issuance also requires the applicant for such permit to file a signed statement tKStHw^js I icensed pursuant to the provisions of the Contractor's License Law (Chapter 9, commencing with Section 7000 of Division 3 of the Business and ProfessToTV^Code) or that he is exempt therefrom, and the basts for the alleged exemption Any violation of Section 7031 5 by any applicant for a permit subjects the app~H-6aa!___tp a civil penalty of not more than five hundred dollars [$500]) SIGNATURE DATE COMPLETE THIS SECTION FOR NQN RESIDENTIAL BUILDING PERMITS ONLY ' Is the applicant or future building occupant required to submit a business plan, acutely hazardous materials registration form or risk management and prevention program under Sections 25505 ?5533 or 25534 of the Presley Tanner Hazardous Substance Account Act' DYES DNO Is the applicant or future building occupant required to obtain a permit from the air pollution control district or air quality management district7 DYES ONO Is the facility to be constructed within 1,000 feet of the outer boundary of a school site? DYES QNO IF ANY OF THE ANSWERS ARE YES, A FINAL CERTIFICATE OF OCCUPANCY NAY NOT BE ISSUED AFTER JULY 1, 1989 UNLESS THE APPLICANT HAS MET OR IS MEETING THE REQUIREMENTS OF THE OFFICE OF EMERGENCY SERVICES AND THE AIR POLLUTION CONTROL DISTRICT CONSTRUCTION LENDING AGENCY 1 hereby affirm that there is a construction lending agency for the performance of the work for which this permit is issued (Sec 3097C i ) Civil Code) LENDER'S NAME LENDER'S ADDRESS 10 APPLICANT'S SIGNATURE 1 certify thnt 1 have read the application and state that the above information is correct I agree to comply with ail City ordinances and State laws relating to building construction I hereby authorize rcpresentat i vc>, of the City of Carlsbad to enter upor '.M? nbovc Mentioned property for inspection purposes I ALSO AGREE TO SAVE INDEMNIFY AND KEEP HARMLESS THE CITY OF CARLSBAD AGAINST ALL LIABILITIES, JUDGMENTS COSTS AND L'XPFNSFS WHICH MAY IN ANY UAY ACCRUE AGAINST SAID CITY IN CONSEQUENCE OF THE GRANTING OF THIS PERMIT Expiration Every permit issued by the Building Official under- the provisions of this Code shall expire by limitation and become null and void if the building or work authorized by such permit is not commenced within 180 days from the date of such permit or if the building or worit nuthorizcd by such permit is suspended or abandoned at any time after the work is commenced for a period of 180 days (Section 303(d) Uniform Building Code) APPLICANT'S SIGNATURE OWNER [^CONTRACTOR []BY PHONE APPROVED BY File YELLOW Applicant PINK Finance PLAN CHECK NUMBER PROJECT NAME _ ADDRESS PROJECT NO TYPE OF UNIT CONTACT PERSON. CONTACT TELEPHONE. FINAL BUILDING INSPECTION RECEIVED JJ5M 3 0 ss DATE 1-2C-30 71 UNIT NUMBER NUMBER OF UNITS PHASE NO INSPEC BY _^^--^ INSPECTED BY INSPECTED BY DATE INSPECTED DATE INSPECTED DATE INSPECTED APPROVED APPROVED APPROVED DISAPPROVED DISAPPROVED DISAPPROVED COMMENTS Rev 1/86 WHITE Suspense BLUE Water District GREEN Engineering PINK Planning PERMITS CB891451 DESCRIPTION: CTI 20842 SF SUITE B TYPE: CTI JOB ADDRESS: 2052 CORTE DEL NOGAL APPLICANT: RAGUE, PATTI CONTRACTOR: BRODWULF OWNER: REMARKS: TEL/MH/ALAN/265-1801 SPECIAL INSTRUCT: FIRE DOOR IS FIXED. CITY OF CARLSBAD INSPECTION REQUEST FOR 03/30/90 & 7958 SF WAREHSE PHONE: PHONE: PHONE: STR: 297-0100 619 265-1801 INSPECTOR AREA MC PLANCK# CB891451 OCC GRP CONSTR. TYPE NEW FL: STE: INSPECTOR TOTAL TIME: —RELATED PERMITS— CD LVL DESCRIPTION PERMIT# TYPE CB900504 SIGN STATUS ISSUED ACT COMMENTS 19 29 39 49 ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ***** INSPECTION HISTORY ***** DATE DESCRIPTION 030990 Final Electrical 030990 Final Structural 012690 Final Combo 011090 Rough Combo 011090 Rough Combo 010990 Rough Combo 010590 Rough/Ducts/Dampers 010590 Rough Combo 122289 Interior Lath/Drywall 121589 Frame/Steel/Bolting/Welding 121589 Rough Electric 121589 Interior Lath/Drywall 121489 Frame/Steel/Bolting/Welding 121489 Rough Electric ACT AP CO CO AP CO PA NR PI PA PA PA PA CA CA INSP MFC MPC MPC MPC MPC MPC MPC MPC MPC MPC MPC MPC MPC MPC COMMENTS NONE HANDICAP COMPLYING DOOR SEE LIST DAUTED 1-26-90 NEW CEILING EXISTING CEILING, SEE LETTER CEILING GRIDS LOW PARTITIONS INT WALLS INT WALLS DIMISHING WALL & WAREHOUSE UNSCHEDULED INSPECTION DATE \3 / 3/ ',-. PERMIT # y JOB ADDRESS Ifo l~~ / / I J-ds M/f'/y\ 6 PLANCK #1 (- ,2. Go?L~T£ J^^-L, AJ(DfZJ&/ TIME ARRIVE: TIME LEAVE: CD LVL DESCRIPTION ACT COMMENTS CORRECTION NOTICE ADDRESS: \) D APPROVED PLANS SHALL BE ON JOB SITE BUILDING D FOUNDATION O REINFORCING STEEL D MASONRY D GROUT-GUNITE D FLOOR AND CEILING FRAME D SHEATHING D FRAME D EXTERIOR LATH D INSULATION D INTERIOR LATH OR DRYWALL PLUMBING D UNDERGROUND PLUMBING D UNDERGROUND WATER D ROUGH PLUMBING D TOP OUT PLUMBING D SEWER AND PL/CO D TUB OR SHOWER PAN D GAS TEST D WATER HEATER N> TD ie- ELECTRICAL D TEMPORARY SERVICE G ELECTRIC UNDERGROUND D ROUGH ELECTRIC D POOL BONDING D ELECTRIC SERVICE D UFER GROUND a GFI D SMOKE DETECTOR MISCELLANEOUS D PLENUM AND DUCTS D COMBUSTION AIR D CONDITIONED AIR SYSTEMS D SOLAR D GRADING D POOL D PATIO D SIGN D OTHER ~ri.-'.o c{c O TIME . DATE INSPECTOR CITY OF CARLSBAD BUILDING INSPECTION DEPARTMENT PHONE 438-3550 Note Final Inspection Required CITY OF CARLSBAD INSPECTION REQUEST PERMIT* CB891451 FOR 01/26/90 DESCRIPTION: CTI 20842 SF & 7958 SF WAREHSE SUITE B TYPE: CTI JOB ADDRESS: 2052 CORTE DEL NOGAL APPLICANT: RAGUE, PATTI PHONE: CONTRACTOR: BRODWULF PHONE: OWNER: PHONE: STR: 297-0100 619 265-1801 INSPECTOR AREA MC PLANCK# CB891451 OCC GRP CONSTR. TYPE NEW FL: STE: REMARKS: T2/MH/ALAN/265-1801 SPECIAL INSTRUCT: TOTAL TIME: INSPECTOR CD LVL DESCRIPTION 19 29 39 49 ACT COMMENTS ST Final Structural PL Final Plumbing EL Final Electrical ME Final Mechanical ££> £&£. t~S^T <£- s&^Q^ CQ \' GO a> W ***** INSPECTION HISTORY ***** DATE DESCRIPTION 011090 Rough Combo 011090 Rough Combo 010990 Rough Combo 010590 Rough/Ducts/Dampers 010590 Rough Combo 122289 Interior Lath/Drywall 121589 Frame/Steel/Bolting/Welding 121589 Rough Electric 121589 Interior Lath/Drywall 121489 Frame/Steel/Bolting/Welding 121489 Rough Electric ACT AP CO PA NR PI PA PA PA PA CA CA INSP MPC MFC MPC MPC MPC MPC MPC MPC MPC MPC MPC COMMENTS NEW CEILING EXISTING CEILING, SEE LETTER CEILING GRIDS LOW PARTITIONS INT WALLS INT WALLS DIMISHING WALL & WAREHOUSE (D t> ® - 2 t (T*k*JLf^^ ^J ^.^J' \7 2/ STADIUMS, GRANDSTANDS. BLEACHERS. PAVILIONS, ' GYMNASIUMS a This facilitv. requires (2 61 Ic 1) wheelchair scaling spaces b When the seating capacity exceeds 300 the wheelchair spaces shall be in more than one locjtion (2-611b 1A2) c Ticket booths must be accessible from both sicks (2 61 Ic 2) d Pjrticip.ition areas such as ball courts exercise rooms, tracks and clubrooms must be accessible (2-611c-3.4) e Spectator and participant samlarv, and locker facilities must con form to the requirements of Chapter 2-5 (2-61 lc-5) DINING, BANQUET AND BAR FACILITIES a Access shall be provided at primary entrances (2 Slid 1) b Wheelchair access shall be provided to all areas w here each l\ pe of functional activity occurs (2 611d 2) c This facilit) requires . (2-611d-3) wheelchair seating spaces d The ratio of removable seating arranged to permit use bv wheelchair occupants is 1 per 20 and based upon the total number of scats pro\ ided (2-61 Id 3) e At least one whe-elchair seal ing space shall be provided for each dining, banquet and bar area (2 611d-3) f Access to wheelchair scaling spaces shall be provided bv 36 minimum clear width -nam aisles (2 611d-3) g Cafeteria line aisles shall be a minimum of 36 clear width (2 6V ld-4) h Access to food preparation areas shall compN with provisions for entrance doors and doorwavs contained in Sect 2330-1 (2-61 ld-6) i Rest rooms and power rooms shall conform to the reouiremenls in Sect. 2-511 (2-6Jia-5) RELIGIOUS FACILITIES a Sancluarv areas S'-IE" l>s accessible (2-SlIe-i} b Provide.«in^slcV-air sealing v-a^.-s in ihe sanctuar Use Section 2-6 , s -1 ,: -J. &-. c Provide whee c*i» r ac~ers to -sistc plalforr-s. nor roorrs cno r lofts, performing a-eas and other similar areas (2 611e-lB) d Assembly areas shall be made accessible (2-61 le-2) e Enclosed and unenclosed platforms and stages in assembK areas shall be made accessible (2-61 le 2) f Classrooms and offices shall have entrv doors that conform to Chapter 33 (2-611e-3) g Sanitary facilities shall conform to the requirements of Chapter 25 (2-61 le-l) CROUP B OCCUPANCY REQUIREMENTS Croup B occupancies used for assemblv purposes but having an occupant load of less than 50 shall conform to all (he requirements for Croup A oc cupancies covered in Section 2 6J1 (2 7]2d) BUSINESS AND PROFESSIONAL OFFICES, PERSONAL AND PUBLIC SERVICE FACILITIES a Client and \isilor areas, office areas and related toilet rooms shall be made accessible (2-712b-2A) b Conference rooms, counseling rooms or cubicles and similar areas shall be made accessible (2 712b 2B) c Emplovee work areas shall have a 36 minimum clear access (2-712b-2C) SALES FACILITIES a General sales, displav and office areas together vv ith related toilet rooms must be accessible (2-712b-3A) b Sales emplovee work stations shall be located on accessible levels Emplov.ee work areas shall be accessible to emplovees in wheelchairs, and the customer side of sales or checkout stations shall be accessible (2-712b 3B) c This facility requires.. check stands accessible to the phvsicall) handicapped based upon 1 for 8 che-ckstands or less. 2 for 9 or more (2-712b 3C) d Where quick check stands are pro\ ided at least one shall be ac cessible (2-712b-3C) e Check stands shall be made accessible b\ providing a 36 aisle on the customer side of the stand (2-712b 3C) f Accessible check stands shall be identified bv the International Symbol of Accessibility and shall state "This check stand to De- epen at all times for disabled customers (2-712b-3C) RETAIL GROCERY STORES (Requirements are staled in AB 179. effective July 1, 1964 ) E Toilet rooms must be p'ov iced 'or the public in stores conta.n- ing more thin 20,000 sq ft of floor ipsc* b The reilet roorrs fcr 'he pub'ic "nay b? the :eme as those provid- es for tr,e tr-.p'ovKS c SeitTe'e fs- 'it a :v-i'j b« prov ded fc- eacS sex c r-i^c czrr-ec rec'j -t1—c-ls she" be sa'n'.e; e Doors shall be self closing f Hand washing facilities shall be provided in Or adjacent to toilet rooms and shall be equipped with hot and cold water g Hand washing detergent and sanitary towels or hot air blowers shall be provided in permanent!} installed dispensing devices SHOPPING CART THEFT PREVENTION BARRIERS a Public entrances and exits shall be accessible to and usable by the handicapped (2-712b 3E1) b Barriers shall provide a 32 clear width opening for handicap- ped ingress and egree (2-712b-3E2) c Note on the plans that shopping cart theft prevention barriers shall comply with the requirements of Sect 2-712b-3E FITTING OR DRESSING ROOMS a Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the ph>sically handicapped (2712b3F) b Minimum dimension of room shall be 60 x 60 (2 712b 3F) c Bottom of the mirror shall be located within 20 of the floor (2-712b-3F) d Height of clothing hooks shall not be greater than 48 from the floor (2-712b-3F) 33/POL1CE DEPARTMENT. LAW ENFORCEMENT, FIRE DEPART- / MENT FACILITIES AND COURTROOMS a Office areas, conference rooms, classrooms, dispatch rooms and similar areas and related sanitary facilities shall be accessible (2-712b-6A) b Detention area visitor rooms shall be made accessible (2-712b-6B) c At least one detention cell facility with supporting sanitary facilities shall be made accessible (2-712b-6C) d Courtroom areas including judges' chambers and bench, counsel tables, )ur> box, witness stand and public seating areas shall be made accessible (2-712b-6D) 3/ FACTORIES a Major or principal floor areas shall be made acessible (2-712c-2A) b Office areas shall be made accessible (2-712c-lB) c Sanitary facilities serving the above shall be made accessible (2.712c-lC) 3S/WAREHOUSES a. Warehousing areas which are located on the floor nearest grade shall be made accessible (2.712c-2A) b Warehousing »re« ono'her floors that are providedwilh access by level entry, ramp or elevator sha'l t< made accessible (2-712c-2A) c Office areas jiall be scc-aible (2-712e-2B) d Sanitary fsciV.ies se^.ng tne above be made access We (2-712c.2C) CROUP R-J. HOTEL, MOTEL AND DORMITORY OCCUPANCY REQUIREMENTS 36/Applies to private!) and public!) funded hotels, molds and dormilor) / buildings and complexes (2 1213a) Provide guest room(s) or dormitory room(s) together with their sanitar) facilities that are accessible to and usable by the ph)sically handicapped (2 1213a-l) b Hotel, motel and dormitory bathrooms bevond those required in item ' a ' above need not comply with the provisions of Sec 2-1213d provided all bathroom entrance doors have a clear open- ing width of 32 inches and are sliding or swing out from bathroom (2 J213d Exception 1) c Every enlrv, opening or passage door opening to an) area must have a 32 mm clear opening (2-1213a 2) d Public and common use rooms shall be made accessible (2-1213a-3) e Recreational facilities including swimming pools shall comply with Sections 2-611c and 2-1107a (2-1213a-4) f Bathroom entrance doorways shall have an IS' clear space to the side of the strike edge of the door on the sw ing side of the door (2-1213d 1) g When accommodations are provided with kitchen units, at least one and no less than one for eve-y 25 of such accommodations provided, shall complv relative to accessible btchen facilities with subsection 2-1213b 2,3,4 (2-1213a-5) ADDITIONS, ALTERATIONS AND REPAIRS TO EXISTING BUILDINGS (2-110b-llB^) 37 jThe area of specific addition, alteration and/or repair, shall compl) s—' with the provisions of this Code fa J The primary entrance to the building and path of travel to the —' specific area shall be accessible to the handicapped persons Restrooms, water fountains, and public telephones which serve said speci'ic area shall &e accessible to handicapped persons (c ) InforrnatiOT regarding handicapped accessibhty shall be posted ^-^ in lobby pe- Set 2-5£2b-8 ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 208 SAN DIEGO, CA 92123 (619) 56O-1468 DATE:AP JURISDICT JURISDICTION: C-/ T &F CSHS U. & & & _ QPLANCHECKERFILE COPY PLAN CHECK NO: <g? - t ^ ) _ SET: X. _ QUPS QDESIGNER PROJECT ADDRESS; 3-05?, c^>IZ.-r& /><gL. PROJECT NAME; «3^/gg^ fn J. ~) The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubmitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. D The applicant's copy of the check list is enclosed for the jurisdiction to return to the applicant contact person. [ | The applicant's copy of the check list has been sent to: •• Esgil staff did not advise the applicant contact person that plan check has been completed. Ij Esgil staff did advise applicant that the plan check has been completed-^_Person contacted: Date contacted: Telephone REMARKS; By; Fh&G' T2OLt&(^T& Enclosures: ESGIL CORPORATION DGA DAA Dvw Q DM ESGIL CORPORATION 9320 CHESAPEAKE DR., SUITE 2O8 SAN DIEGO, CA 92123 (619) 56O-1468 DATE: 10- ?~ ^ _ l"1 APPLICANT" ~ JURISDICTION: ClTy Q£ t2rtfg>.<>8rtP> _ _jPLAN (JHECKKK' QFILE COPY PLAN CHECK NO: &*? - I U- S, I _ SET: X _ QUPSF DESIGNER PROJECT ADDRESS; 3.QS2_ cc?f27(f 'Dec, tJo6>ul_ PROJECT NAME; OFF/Cp^ ( T, X The plans transmitted herewith have been corrected where necessary and substantially comply with the jurisdiction's building codes. The plans transmitted herewith will substantially comply with the jurisdiction's building codes when minor deficien- cies identified _ are resolved and checked by building department staff. The plans transmitted herewith have significant deficiencies identified on the enclosed check list and should be corrected and resubiuitted for a complete recheck. The check list transmitted herewith is for your information. The plans are being held at Esgil Corp. until corrected plans are submitted for recheck. The applicant's copy of the cneck list: is enclosed for rne jurisdiction to return to tr.e applicant: contact person. The applicant's co^y of ~ne cr:ec": list ~as oeen ser~ re: ? 'Z- //) ^^ Esgil staff did not advise the applicant contact person that ^ plan check has been completed. (~Tj Esgil staff did advise applicant that the plan check has ^-^ been completed. Person contacted: Date contacted: Telephone # REMARKS: By: ft&ir E®<L/£fJT& Enclosures: ESGIL CORPORATION /o_2 ^ DGA DAA Dvw QDM PLAN COKKKCTION SHEET TENANT IMPROVEMENT PLAN CHECK HO.: JURISDICTION: TO: fZ.it> -S&/J D£ S7F 0X3 PROJECT DATA OCCUPANCY: BUILDING DSE: TYPE Of CONSTRUCTION: ACTUAL AREA:, ALLOWABLE AREA:_ STORIES: HEIGHT: 7 ^ SPRINKLERS: OCCUPANT LOAD:•2.1 REMARKS: Date plans received by jurisdiction- Date plans received by Esgil Corporation: / D - 3.- g^ 7 Date initial plan check completed / i - 7 _ <? f Bv ^ Applicant contact person: 237-0)0 0 FOREWORD: PLEASE READ Plan check is limited to technical requirements contained in the Uniform Building Code, Uniform Plumbing Code, Uniform Mechanical Code, National Electrical Code and state laws regulating energy conservation, noise attenuation and access for the handicapped. The plan check is based on regulations enforced by the Building Inspection Department. You may have other corrections based on laws and ordinances enforced by the Planning Department, Engineering Department or other departments. Code sections cited are based on the 1985 UBC. The circled itsa? listed ne-'-'i clarification, noeification or change All items must be satisfied bet era trie pls^r.s vill 3.° m coiforciar.ee vit.i the ci^eJ COC.JE -iJis r3gi..iations -er Sec 303(c), 1985 Uniform Building Coae, the approval of the plans does not permit the violation of any state, county or city law. To speed up the recheck process, note on this list (or a copy) where each correction item has been addressed, i e.. plan sheet, specification, etc Be sure to enclose the marked up list when you submit the revised plans NOTE: PAGE NUMBERS ARE NOT IN SEQUENCE AS PAGES HAVING NO ITEMS NEEDING CORRECTIONS WERE DELETED. LIST NO 90, TENANT IMPROVEMENT WITHOUT SPECIFIC ENERGY ZONE DATA OR POLICY SUPPLEMENTS, 1985 UBC 0 S 0 ^ © X Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to Esgil Corporation, 9320 Chesapeake Drive, Suite #208, San Diego, CA 92123, (619) 560-1^68. Please make all corrections on the original tracings and submit two new sets of prints, and any original plan sets that may have been returned to you by the jurisdiction, to: The jurisdiction's building department Indicate on the Title Sheet of the plans, the name of the legal owner and name of person responsible for the preparation of the plans. Section 302(a)7. Each sheet of the plans must be signed by the person responsible for their preparation, even though there are no structural changes Business and Professions Code Plans and calculations shall be signed by the California state licensed engineer or architect where there are structural changes to existing buildings or structural additions. Please include the California license number, seal, date of license expiration and date plans are signed. Business and Professions Code Provide the correct address and suite number of tenant space on the plans Section 302 Provide a note on the site plan indicating the previous use of the tenant space or building being remodeled. Section 302. When the character of the occupancy or use changes within a building, the building must be made to comply with current Building Code requirements for the new occupancy. Please provide complete details to show the building with comply. Section 502. UBC Section 33^ requires the Building Official to determine 'Lne ~ot-sl sl^e cf all construction ViOrt; proposed uncer this perrcit The valis s.h-11 include all finish v;rr. painting, -cofiir electrical, pi-sb-riP heating, air conditioning, eleistcr £_re extinguishing systems and any other permanent equipment. Please provide a signed copy of the designer's or contractor's construction cost estimate of all work proposed. Provide a plot plan showing the distance from the building to the property lines and the location of tenant space (or remodel) within the building. X X On the first sheet of the plans indicate Type of construction of the existing building, present and proposed occupancy classifications of the remodel area and the occupant load of the remodel areas and the floor where the tenant improvement is located Provide a note on the plans indicating if any hazardous materials will be stored and/or used within the building which exceed the quantities listed in UBC Table 9-A Provide a statement on the Title Sheet of the plans that this project shall comply with Title 2U and 1985 UBC, UMC and UPC and 1987 NEC. Provide a fully dimensioned floor plan showing the size and use of all rooms or areas within the space being improved or altered. Draw the plans to scale and indicate the scale on the plan Indicate the use of all spaces adjacent to the area being remodeled or improved. Show any existing fire rated area separation vails, occupancy separation walls, demising walls, shafts or rated corridors. Identify and provide construction details for proposed new fire rated walls Specify on the plans the fire ratings of assemblies to protect proposed openings in existing or new fire walls. Identify existing ^alls to be removed, existing walls to remain and proposed new walls. Identify bearing walls, non-bearing walls, and shear walls. Provide a partitions. section Show: view of all new interior & Type, siza and spacing cf studs. Indicate gauge for metal studs. Specify manufacturer and approval nomber or indicate "to be IC30 approved", ••'ethod cf attaching top ana bottoc plates to structure (x.OrH Top of partition nust be secured to roof or floor fraemg, ^*il£E3 suspe-ried ceiling has oeen ceiig-.ed for pi.-t--:on liberal .cac) Va.il Ev;eathi':g •Miteria.l and oet^iis cf attachment (size and spacing of fasteners). Show height of partition and suspended ceiling, and height from floor to roof framing or floor framing. fc, 5/16/89 Provide notes and/or details to show that the floor and wall finish in toilet rooms are surfaced with a smooth hard non-absorbent material extending five inches up the wall Similar surfacing shall be provided on the walls from the floor to a height of 4 feet around urinals and within water closet compartments Section 510(b). Note on the plans "All interior finishes must comply with Chapter 42 of the UBC". Specify "class flame spread rating (minimum) for ." Lateral bracing for suspended ceiling must be provided. (UBC Table 23-J) Where ceiling loads are less than 5 PSF and not supporting interior partitions, ceiling bracing shall be provided by four No 12 gauge wires secured to the main runner within 2 inches of the cross runner intersection and splayed 90_ from each other at an angle not exceeding 45_ from the plane of the ceiling. These horizontal restraint points shall be placed 12 feet o c. in both directions with the first point within 4 feet of each wall Attachment of restraint wires to the structure above shall be adequate for the load imposed In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and floor above so that no concealed space exceeds 1,000 s f. and no horizontal dimension exceeds 60 L F. (if space has sprinklers, then 3,000 s.f and 100 L F.). In buildings having floors and roofs of wood frame construction, other than dwelling or hotel occupancies, draft stop the area between the ceiling and roof above so that no concealed space exceeds 3,000 s.f. and no horizontal dimension exceeds 60 L F. (if space has sprinklers, then 9,000 s.f. and 100 L.F.). The tenant space and r>ew and/or existing facilities serving the remodeled area oust be accessible to and functional for the physically disabled. See the attached correction sheet. Title 14, ?^rt 1 The width cf tha required level area on the side Lntc viii c;."rn s»".g E.-vail -rvts."^ C.,. inches past tna strike eage for e>ter_cr corrs and 18 inches past the strike edge for interior doors. Section 2-3304, Title 24. Specify lever-type hardware for passage doors on floors accessible to the disabled. Section 2-3304, Title 24 If both sexes will be employed and the number of employees exceeds four, provide separate toilet facilities for men and women. If "both sexes will be employed and the total number of employees will not exceed four", and only one restroom is provided, note the words in quotation above on the floor plan Section 705 In areas where the occupant load exceeds two exits are required See Table 33-A 30 ) Provide an exit analysis plan (may be 8 1/2" x 11" or any convenient size). Exits should have a minimum separation of one- half the maximum overall diagonal dimension of the building or area served. Section 3303(c) The maximum number of required exits and their required separation must be maintained until egress is provided from the structure. Section 3303(a) /35 Rooms with more than 10 occupants may have one exit through one adjoining room. Revise exits to comply. Section 3303(e). ,34 ] Exit signs are required for exits serving an occupant load exceeding 49 Show all required exit sign locations Section 3314(a). Show that exits are lighted with at least one foot candle at floor level. Section 3313(a). Show the locations of existing exits from the building and show the path of travel from the ,remodel area to the existing exits. Note on the plans: "All exits are to be openable from inside without the use of a key or special knowledge". In lieu of the above, in a Group B occupancy, you may note "Provide a sign on or near the exit doors reading THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS IOURS". Section 3304(c). Exit doors should ba & nuninum size of 3 feet ?•»• 6 feet 3 inches v^tn s. -D-.r_Ej~ door svirsg cf 90 degrees Kaxiaum leaf width is 4 feet EM.L doers shoula svng n the direction of egress when serving an occupant load of 50 or more or when serving any hazardous area. Section 3303(b). Applies to door(s) 5/16/89 4/Regardless of occupant load, a floor or landing not more than 1/2 inch below the threshold is required on each side of an exit door used for disabled access (may be 1" maximum where not used for disabled access) Section 3304(h) Doors should not project more than 7 inches into the required corridor width when fully opened, nor more than one-half of the required corridor width 3305(d). when in any position. Section Revolving, sliding and overhead doors are not permitted as exit doors if the occupant load exceeds 9 or the exit door serves a hazardous area. Section 3304(g). Exit doors from assembly rooms with 50 or more occupants shall not be provided with a latch or lock unless it is panic hardware. Section 3318. Double acting doors are not allowed when serving a tributary occupant load of more than 100, or when part of a fire assembly, or part of smoke and draft control assemblies or when equipped with panic hardware. Section 3304(b). Corridors must provide continuous protection to the exterior of the building. Interruptions by an intervening room is not permitted. Foyers, lobbies or reception rooms constructed as required for corridors are not considered intervening rooms. Section 3305. Corridors and exterior exit balconies serving 10 or more occupants must be a minimum 44 inches wide and 7 feet high to the lowest projection. Section 3305(b). When a corridor or exterior exit balcony is accessible to the handicapped, changes in elevations shall be made by means of a ramp. Section 3305(f). When two exits are required, dead end corridors and exit balconies a^e IimiteG to 20 feet. Section 3305(e). Corridors serving 30 or core have walls ar.c ceilings construction except. occjroar-s sh»li cf one-nour a. Comoc.-s i,rcatsr than 20 fe^i vice vntn the occuptr.ts have an exit independent from the corridor. b. Exterior sides of exterior exit balconies. c. One story buildings housing Group B, Division 4 occupancies Section 3305(g). If non-rated corridors are used per 1985 UBC, Section 3305(g), Exc. 5, provide a reference to the corridors on the floor plan, noting Corridors are non-rated per 3305(g), Exception 5, 1985 UBC Section Smoke detection system must be listed by the State Fire Marshall and be a supervised low voltage system vith combination audible and visual signals with battery backup Smoke detectors center shall be maximum 30' on 4 Combined audible/visual signal device(s) shall be installed just inside of each exit door from the corridor, also all locations in the corridor must be in sight of a signal device. 5. Power supply shall be dedicated branch circuit. Circuit disconnecting means shall be accessible only to authorized personnel and shall be clearly marked FIRE ALARM CIRCUIT CONTROL, with a lock- on device. 1985 UBC Section 3305(g), Exception 5, cannot be used for non-rated corridors in a fully sprinklered office space if the occupant load in the space exceeds 100. 1985 UBC Section 3305(g), Exception 5, is applicable to the office space but does not apply to the common corridor where the tributary occupant load appears to exceed 100 occupants. When 1985 UBC Section 3305(g), Exception 5, is applied for corridors on one floor, the corridors on the lower level(s) must be rated if these lower corridors serve more than 100 occupants. The tributary load from the upper level(s) snail be the total occupant load fron the above level(s). Clearly shov where the non-rated corridor syste.1 terminates and 2. ratec ccrrido-- Ejstem coaaences. fire-rated corr_dor? shsll have doer C -ic;*~i.l-^l£S TT jTC*"k.SC t.£G L'" ^.-.^Tit ™ r 1.1- wi-T"!^ ErtJOjC.5- c^lQ draft control asseatlies ratea 20 minutes, except openings in interior walls of exterior exit balconies. Doors shall be maintained self-closing or be automatic-closing by action of a smoke detector per Section 4306(b). Doors shall be gasketed to provide a smoke and draft seal where the door meets the stop on sides and top. Section 3305(h). 5/16/89 Show rated corridors, lobbies, reception or foyers cross-hatched on the floor plans. Total area of all openings, except doors, in any portion of an interior corridor, shall not exceed 25 percent of the area of the corridor wall of the room which it is separating from the corridor. Such openings shall be protected by fixed, approved 1/4 inch thick wired glass installed in steel frames. Section 3305(h) Provide a complete architectural section of the corridor, or exterior exit balcony, showing all fire-resistive materials and details of construction for all floors, walls, ceiling and all penetrations. Section 3305(g). Show the location of fire dampers. Provide fire dampers at duct penetrations of fire- rated occupancy and area separations, shafts and corridor walls and ceilings. Section 4306(j). If building exceeds two stories, show corridor is separated from elevator shaft Sections 3304(g)(h) and 1706(a)(b) (See 1C B.C. interpretation). Provide evidence of Health (for restaurants or for equipment). Department approval tenants using X-ray ELECTRICAL 62. Submit plan shoving location of all panels. 63. Subm\t panels schedules. 64. Submit^ electrical load calculations 65. Indicate existing main service size. 66. Indicate Wisting total main service load. 67. Indicate new additional loads. 68. Indicate wirVng method, i.e. EMT, metal flex. 69. Show exit signs en the electrical lighting plan. Note:\ Power for exit lights and emergency iL-.-.trsng sr-st cer-forai to the 1935 TJBC Sections 33IC *rA 3314. 70. Provida recer-t^ciWs) vi^-hin 25' cf the rocf oounted > G J-its \UM2 Section 509. 71. Provide multiple switch lighting controls per CAC, Title 24, 2-5319i 72. Provide an electrical p\lan for the alarm system showing compliance wkth criteria described under earlier correction number 50. MECHANICAL Provide mechanical ventilation in all rooms capable of supplying a minimum of 5 cubic feet per minute of outside air with a total circulation of not less than 15 cubic feet per minute per occupant. Section 605 and 705, UBC. Provide mechanical plans showing existing and proposed HVAC equipment, ducts and access to equipment. Detail access and working clearances to HVAC equipment Cooling coils or cooling units located in attic or furred space, where damage may result from condensate overflow, shall be provided with an additional water tight pan of corrosion resistant material to catch overflow if primary condensate drain becomes clogged. Section 1205, UMC. One-hour corridors shall not be used as an integral part of a duct system. This includes the space above a dropped ceiling within the one-hour corridor. UMC Section 706(b). TLGMBIHG Provide gas line plans and calculations, showing pipe lengths and gas demands. UPC Section 1219. Provide drain, waste and vent plans. Provide water line sizing calculations. UPC Section 1009. Detail how floor drain trap seal is to be maintained. UPC Section 707 (floor drain trap priming). Show P & I valve on water heater and detail drain line route from P & X valve to the exterior. UPC Section 1007(e). Show 1/4" per 12" slope on drain and waste lines. UPC Section 407. P.cvide conrrlete e-*erpv design c-alc^latior.s. dssign for this zr-ilaing. See attached ion- residential energy design checklist. For remodels in an existing conditioned space, show that the remodeled space will use not more energy than the existing space or show the remodeled space will conform to latest energy design standards. 6/8/89 Please see additional corrections or remarks that follow. The jurisdiction has contracted with Esgil Corporation located at 9320 Chesapeake Drive, Suite 208, San Diego, California 92123; telephone number of 619/560-1^68, to perform the plan check for your project. If you have any questions regarding these plan check items, please contact at Esgil Corporation Thank you. Enclosures- 1. 2. 3. 5/16/89 (L ELECTRICAL JURISDICTION:*. AfLL S H> A- / FLAN CORRECTION SHEET DATE: ELAN CHECK HIMKKR: Y ? ' Submit complete electrical plans and specifications. Submit plan showing location of all services. Submit complete one-line diagram of service and feeders. Indicate the grounding system to be installed for building service. Indicate ampere interrupting capacities (AIC) of service and subservice equipment. NEC 230-65/110-9. Indicate sizes of fuses and/or circuit breakers Indicate fuse symbols to show fault currents are limited to 10,000 amps on branch circuits, i.e. JJN, LCL. If fuses are not used to limit fault currents on branch circuits to 10,000 amps, specify method to be used. Submit plan showing location of all switchboards. 10. Indicate dimension of switchboards and control panels rated 1200 amperes or more. NEC 110-16(c). 11. Submit plan showing location of all transformers. 12. Indicate the grounding system to be installed for transformers. NEC 250- 26(c). QVOLLIE WAGGONER PLAN CHECKER: ["3-OWEN DILLON j—| DARRELL MORRISON 13. Provide overcurrent protection on the secondary side of transformers. NEC 240- 21/384-16(d) Submit plan showing location of all panels. (S\ Submit panel schedules. 16. Specify conduit and wire sizes. 17. Specify aluminum or copper conductors and type of insulation .}Show approximate length of feeders 19. Specify electrode conductor size and type wire, (aluminum or copper) 20. Submit electrical load calculations. 21. Indicate existing service size. 22. Indicate existing building load. 23. Indicate new additional loads. 24. Indicate wiring method, i.e. EMT, metal flex. 25. Show exit signs on the electrical lighting plan. Note: Power for exit lights and emergency lighting must conform to the 1985 UBC Sections 3313 and 3314. 26. Provide receptacle(s) within 25' of the roof mounted A/C units. UMC Section 509. 27. Provide multiple switch lighting controls per CAC, Title 24, 2-5319. Any questions on electrical please contact the plan checker shown above, at Esgil Corporation at (619) 560-1468. Thank you. 08/31/87 ue gu. •3 Si 1 !n £u u 3 « UU. Uo o -o3 Cis •» a < aCex «Je c TITLE 24 HANDICAPPED ACCESS CORRECTION LIST Addlrtt Pl.n Ck No Jlem number* circled be/on are required lor this project See Title 2-t 2 HOb 11 Circled items do not appl\ to noon uhich arc not required to be han dicjpped jccessibie References to section numbers " ith prefn 2 are to Title 2-1, Part 2 (SUte Building Code), 1955 Edition Prefn 3 is for Pjrt 3 (State Electrical Code) Prefix 5 is for Part 5 (Stjie Plumbing Code) E\emptions chimed for am i(em shall be requested in u riling and ih*ll include a// djtJ needed to determine unrejsonjble hardship as described in Section 2-122 SITE DEVELOPMENT HANDICAPPED PARKING SPACES a See Approved Parking Plan for lajout (Fig 271-1) b Provide handicapped spaces (2-7102a) c Space shall be so located that handicapped persons are not com- pelled to wheel or w alk behind parked cars other than their own (2 7102c) d Parking space shall be a minimum of 9 ft x 18 ft with adjacent 5ft loading zone Double space shall be 23 ft wide (27102b, Fig 2-71-1) e Maximum slope of parking surface in anv direction shall not ex- ceed '/»" per foot (2 7102d) f Parkingspace(s) shall be identified with the International Sym- bol of Accessibilit) on reflectonzed sign affixed to post or wall, and also duplicated on parking surface (svmbol to be 36 x 3S") (2-7102e) g Entrance to parking facility or structure shall also have durable metal sign stating that unauthorized vehic'ie(s) parking in han- dicapped space(s) may be subject to tow-away (2-7102e) h Entrance to and vertical clearance within accessible level of park- ing structure shall be 8 ft 2 in to any structural member, duct or pipe (2-7102f) CURB RAMPS a Curb ramps sha'l be located wherever pedestrian path c-osses curb (2-7'l03a) b Curb ramp shs". De -iS mm width (2-7103b) \vilh maximum slope of 1 in 12 (2-7103=) c A!eve'-S nir cepth 'ending is reojired at ton o1' curb ra-np over cnu-e c»r5 -ar-p •» dth (2-75C?=) d If no lane ng s p-c-- sed, tre slope o' fared :ides ihaii ->ot tx cced 1 in 12 (2-7103d) e Surface is to be slip resistant (2-7103f) f Border markings shall be 12" wide of '/«" x Vt~ grooves, '/«" apart, located at top and sides (2-7103h) WALKS a Site development and grading shall be designed to provide ac- cess to primary entrances and access to normal paths of travel and where necessary to provide access shall incorporate pedestrian ramps, curb ramps, etc (2-7101 a) b Walks sloping greater than 5% (1 in 20) must comply with ramp requirements of sect 2-3307 (2-3325ri c UaU width shall be AS" n1n1mum, (2-332Sa), and shall have slip-resistant surfaces as that described as a medium salted finish d The maximum cross slope shall not exceed Vi per foot (2-3325a-3) e Gratings are not allowed whenever possible (2-3325b) f At each gate or door a 60 x 60 level area is required when the gjte swings toward the walk (2 3325e) g A 24 clear space is required at strike side of gate or door (2-3325e, Fig 2-33-2) h A 4S x 44" deep level area is required when the gateswmgs aw jv from the walk (2 3325e) 'PEDESTRIAN RAMPS a A path of travel with a slope greater than 1 in 20 shall be con- sidered a ramp (2-3307a) b The maximum slope shall be 1 in 12 (2 3307c) c The width shall be <S" minimum, (Z-3307b-3), and shall have slip-resistant surfaces d A 60 intermediate landing is required at maximum elevation change of 30 and 72 landing at each change of direction (over 30°) (2-3307d-l) e Landings are required at top and bottom of ramps (2 2307d 1) f. Bottom landing shall be minimum of 72" in the direction of travel (Fig 2-33-11 A) g Top landing shal1 be 60" x 60 minimum (2-3307d 2) h \Vnen door swings or.to top landing, mnmum depth of larding required is door width plus 42 (Fig 2-33 1M) : T^p ia~d'~g iha'i "Eve r»0 ' mi~. v.idih whs-, coor swings oito thi 's-idirj, A th C4" on str'ke nee of door at exte-icr ramp, or 13" f snt'.'ior -STO (2 3307o'-!) Fur? Sa-c-si's z-e -ecu-e exceeds 1 .n 15 (2-3307e) ;e c' 'a~p, when slope k Ramp handrails shall be continuous, located 30 34 in height above ramp surface, with 12" extensions beyond top and bot- tom, and the ends returned (2-3307e) 1 Handrails shall be 1 V* to 2 cross section, spaced mm of I-1/: from w all (2 3307e) m A 2 high curb or wheel guide rail centered 3 plus/minus 1 above ramp surface is required on both sides where not other- wise bounded bv walls when the ramp exceeds 10 feel in length (2-3307h) ACCESS LIFTS Lifts mav be provided between levels, in lieu of elevator, when the vertical distance between landings, structural elevator, struc- tural design and safeguards are as allowed by the State of Califor- nia, Dept of Industrial Relations, Div of Occupational Safetv and Health (2 5106a) HAZARDS a Provide 80" headroom from walkway surface to anv overhang- ing obstruction (2 3326b) b Headroom of 80 ' minimum shall be maintained for walks, cor ridors, aisles, etc (2 522f 2) c Protruding objects, w ith leading edges betw een 27 and 80 above finished floor shall not protrude more than 4 into walks, cor ndors, etc (2 522M, Fig 2 5-7) d Objects w ith protruding edges below 27 above finished floor may protrude any amount (2 522M) e Free standing objects mounted on posts between 27 and SO" above the floor may project a maximum of 12 (2 522f 1) f Abrupt changes in level exceeding 4 adjacent to walks except between walks and adjacent streets or drives shall be idenlifie-d b> 6 high warning curbs above walk surface (2 3326a) ENTRANCES AND CIRCULATION ENTRANCES. DOORS. VESTIBULES AND CORRIDORS a All primary entrances to buildings shall be accessible to the han- dicapped (2-33011) b All required passage doors shall have 32" clear opening et 90° (36" door) (2-330<e-l) c At least one of a pair of doors shall meet the mm 32 clear en trance width requirement (2-3304e-3) d Threshold shall be ro higher than Vt' above the floor Edge to be beveled with aslope no greater than 1 in 2, if more than '/<" (23304h-l, Fig 2335) e Exterior lev el landing ma> slope up to'/» per foot in anv direc- tion for surface drainage (2-413) f Door hardware shall be of the lever or push tvpe, mounted 30 to 44 ' above the floor and be operable with a max effort of S 5 Ibs for exterior doors and 5 Ibs for interior doors (2-3304c-3. 2-33041-2) g The lower 10" of'.he door shall be of siioo'h, p'ane su-'acc (no recess or trap) except at automatic and slid.rig doors (2 3304."-) (hj Building entrancc(j) shall be identified bv sign wilh the !r!er- r.alional Svr;b?l c' Arses*.31'..tv Svow "rcst'ir ci >re :>'". (2 522b-7) Tie s\~>:x>l shall be a white figure on olue background y^-o—D ?i \ At turns'ile, p-sv c; si access ga'c, 32 cleir w i;t- epenrg within 30 feet of turnsole (2 3304n) j There shall be a clear area on each side of door, 60 deep in direc- tion of door swing and 44 deep in opposite direction of door swing (2-3304h-2) k Width of clear area on the swing side of the door shall extend 24 past strike jamb for exterior doors and 18 past strike jamb for interior doors (2-3304h-2) 1 The space between two consecutive doors (vestibule) shall pro- vide a min of 4S" clear depth between the open door and a se- cond closed door (2-3304h 2D, Fig 2-33-5A) Doors in a series at a vestibule shall swing in the same direction, or awav from the space between them (2-3304h-2D) m Corridors shall be 44" minimum in width or as required bv oc- cupant load (2 3305b 1) n For corridors ov er 200 feet long, see special requi rements of Sec 23305b-2 (Fig 2-33-6) FLOORS a Floors of a given storv shall be a common level throughout or shall be connected by pedestrian ramps, passenger elevators, or special access lifts (2 522e) STA1RWA1S a Treads shall have smooth, rounded exposed edges and be slip resis- tant (2-3306s-l) b Nosing shall not project more than I1/: past face of the riser below (2-3306s-2) c Risers shall be sufficiently solid (2 3306s 3) d The upper approach and lower tread of each flight of stairs shall be marked with a contrasting colored strip 2 in width (2-33060 e On exterior stairs, each tread shall be marked as noted above (2-3306r) f Handrails are required on each side of stairwav (2 3306) 2) g Handrails <('all be located 30 to 34 above nosing, extend 12 bevond lop riser and 12 plus tread width bevond bottom nos- ing and returned to wall/newel post (2-3306) 2) h Handrails shall be 1 '/« to 2 in gripping cross section and 1'/: clear of wall (2 3306) 2) ELEVATORS a See Chapter 51 of UBC for car size b Passenger elevators in buildings other than those listed in Chapter 51 of UBC servmyan occupant load of more than 50 shall have a car size 65 wide bv 51 de-ep with a mm clear opening width of 36 (25103m-2Bl) c Passenger elevators in buildings other than those listed m Chapter 51 of UBC scrvme an occupant load of 50 or less shall have a car size of 54". wide by 54 deep with a minimum clear opening width of 32 (2 5103m-2B2, 3) d . Raised Braille markings and Arabic numerals arc required on con- trol buttons and door jambs (2-5103m) S'A'IT'.RY FACILITIES FACILITIES ACCESS a V hen loci ec CP scccsibls "oo-s s?.ii'£-\ 'ac '.'t.es sha.! bs rrace sccvisibie to phvsicziiv ra-xiicapped (2 51!a-3) c Dc-orwa • s-tu hiv- 2-" — rirr.j—. fei' \vicll< (2 oila-5i) c T'lere shall be a level area with 60 clear depth in the direction of the door swing, and a level area with 44 clear depth m op- posite direction of door swing (2-511a-5B) '12 "^MULTIPLE ACCOMODATION TOILET FACILITIES a Prov ide clear area 60 diameter x 27 high or clear space 56 x63 x27 high (251U6A) b Doors (other than handicap compartment) are not to encroach more than 12 into above mentioned clear space (2 51 la 6A) c Prov ide 2S clear space between w atcr closet and fixture or 32 clear space between water closet and wall (2 511s-6B) d A 4S' long clear space is required in front of water closet A 60 ' clear space is required when the toilet compartment has a side door (2 511a-6B) e Water closet compartment door to provide 32 clear width for end enlrj and 34 clear width for side enlt^ Door to be self closing (2-51 la 6C) SINGLE ACCOMODATION TOILET FACILITIES a Water closet shall be located 28 from a fixture or 32 from a wall (251]a-7. Fig 2-5 1A) b Minimum clear space in front of water closet shall be 48 (2-51U7, Fig 2 5-1 A) c In an existing building, a single accommodation toilet facilitv mav have a space 36 wide x 48 long in front of water closet (2511a-7, Fig 25-1C) CRAB BARS AT WATER CLOSET a One at side 42 long extending 24 in front of w ater closet one at rear 36" long centered on water closet, both mounted 33" above floor (2511a-8A) b Bars shall be I'-l" to l'/i in diameter with I1/: clearance to wall (251)a-8B) c Bar fasteners and mounting support shall be able to withstand 250 Ibs /ft in bending, shear and tension (2-5Ha 8C) WATER CLOSET a Height of water closet seat shall be 17 to 19 above floor (51502) b The force required to activate the flush valve shall be 5 Ibs max- imum (5-1502) )URINALS a Where urinals are provided, the rim of at least one shall project 14" from the wall and be located 17 maximum above floor (5-1503a) b The force required to activate the flush valve shall be 5 Ibs max- imum and located 44" maximum above floor. (5-1503b) c Provide 30' x 48' clear floor space for forward approach (2-511b-4) WATOR1ES a Provide 30" x <S clear floor soace for forward approach Said clear floor space nav include knee and toe space under 'avalc-v described below (2. 5Ub-lA) b. Provide clear space btnea'h lavatories 29 hiyS bv 30 widebv S"deep (Lr.e? spaced c-ic: S h i,"1- f"on "-e loir tv J/- *S'_e l\ 17 dtep from i-ont of Uvator, (toe space) (5-15CXa) c^ Hot v\atcr anc C-EI-, oioei unccr ;av j'.o-.e: s.-^JI bs i'sj a es d Faucet controls and operating mechanism (operable with one hand) shall be of the type not requiring tight grasping pinching or twisting of the wrist and an operating force not exceeding 5 Ibs (5-150-tc) e Self closing valves to remain open for at least 10 seconds (5 )50-lt) 1 S )TO1LET ROOM ACCESSORIES a Mirror bottom edge shall be located 40 maximum abov e floor (2-5 lib-IB) b Toilet tissue dispensers shall be mounted within 12 fromthcfront edge of toilet seat (2511b-3, Fig 2-5-1 A) c Operating parts of dispensing and disposal fixtures (towels, waste, coin slots, etc ) shall be within 40 of floor (2 511b 2) '19 JSAMTARY FACILITIES IDENTIFICATION a On doorwavj leading to samtar) facilities the sv mbols to be pro vided are 12 Equilateral Trunglc for men, 12 Durncler Cir- cle for womin and Vi thick, centered on door, 60 high con trailing color (2 Slla 5C) f20\BATH]NC FACILITIES a One such facilitv shall compK when provided for the public, clients or emplovees (2 51 la 9} b Shower compartment shall be 42 wide, 48 deep, with a 36 wide entrance (2-511a9Al) c Note on the plans that the handicappped bathing facilities shall conform to requirements of Sect 2 51 la 9, 5 1505-Band5 1506 GENERAL REQUIREMENTS FOUNTAIN a The alcove in which the water fountain is located shall be not less than 32 wide bv IS deep (2-51 Ic. Fig 253) b Note on the plans that drinking fountain shall conform to re- quirements of Sec 2-51 Ic and 5 1507 '22 } PUBLIC TELEPHONE a Provide space 30 x 48 for forward or parallel approach to telephone (2-51 Id2) b Note on the plans that public telephones shall conform to re- quirements of Sec 2-511d [23 ^ELECTRICAL REQUIREMENTS a 15, 20 and 30 amp receptacle outlets shall be installed not less than 12 above floor (3-210-SOe) b Center of switch shall be located not less than 36" nor more than 48 above the floor (3-3SO-8c) c If emergency warning systems are required (tn buildlnss regulated by the O'flce o* t,S» S'f.e Architect), they stall icftvets i netrs of kirn'n; the hearing 'mps.rei Flashing Visual warn'rig shall a 'requency of not nore then 60 flashes per it nute Section CROIP A OCCIF'NCV REQUIREMENTS ^^.E'-O'Il.'JS 'SSi1';..^ ~.*_LS, T-t'TZ-S. ETC a Seating ana toilet facilities for the handicapped shall be accessi- ble from the main lobbv or pnmarv entrance (2-611b-l) This structure requires . (2611b 1A1) wheelchair seating spaces Each wheelchairspaceshallbeBO x 30 andlevel (2611blA2) W'hen the seating capacitv exceeds 300, the wheelchair spaces shall be in more than one location (2-611b-lA2) e This structure requires seats for semi ambulant per- sons Clear leg space shall be at least 24 (2611b-lB) Stages, enclosed and unenclosed platforms, orchestra pits, ticket booths, and refreshment sales facilities shall be made accessible (2-61 Ib 2, 3) 2/ STADIUMS. GRANDSTANDS. BLEACHERS. PAVILIONS, ' GYMNASIUMS a This Facililv requires , (2611c 1) wheelchair sealing spaces b When the seating capacity exceeds 300 the wheelchair spaces shall be in more than one location (2 611b-lA2) c Ticket booths must be accessible from both sicks (2 61 Ic 2) d Participation arcal such as ball courts exercise rooms, tracks and clubrooms must be accessible (2 611c-3 4) e Spectator and participant sanitary and locJ.tr facilities must con- form to the requirements of Chapter 2-5 (2-61Ic 5) DINING, BANQUET AND BAR FACILITIES a Access shall be provided at primary entrances (2 61 Id 1) b Wheelchair access shall be provided to all areas w here each t\ pe of functional actiMtv occurs {2 611d 2) c This facilit) requires . (2 611d 3) wheelchair seating spaces d The ratio of removable seating arranged to permit use bv wheelchair occupants is 1 per 20 and based upon the total number of scats provided (2 61 Id 3) e At least one whix-lchair sealing space shall be provided for each dining, banquet and bar area (2 61 Id 3) f Access to wheelchair scaling spaces shall be provided b\ 36 minimum clear width Ttain aisles (2 611d-3) g Cafeteria line aisles shall be a minimum of 36 clear width (2-61ld-4) h Access to food preparation areas shall complv with prov isions for entrance doors and doorwavs contained in Sect 2 3304 (2 61 ld-6) 1 Restrooms and power rooms shall conform to the reouiremcnls in Sect 2-511 (2-6Iic-5) RELIGIOUS FACILITIES a Sanctuan areas s'"r" t>2 accessible (2 Slle-i} b Provide.r>ee!cVsir seating ^car-.-s in i Use Section 2-* j c- .» v-?!-t>- A> c Proxide wheeicSc ' access :o-sued plalfo—s, c"isi-.ocr-s 03 r lofts, performing a*eas and other similar areas (2 611e-IB) d Assembly areas shall be made accessible (2-61 le-2) e Enclosed and unenclosed platforms and stages in assemblv areas shall be made accessible (2-61 le 2) f Classrooms and offices shall have entrv, doors that conform to Chapter 33 (2-611e-3) g Sanitary facilities shall conform to the requirements of Chapter 25 (2-61 le-1) CROUP B OCCUPANCY REQUIREMENTS Croup B occupancies used for assemblv purposes but ha\ ing an occupant load of less than 50 shall conform to all the requirements for Croup A oc cupancies covered in Section 2 611 (2 712d) BUSINESS AND PROFESSIONAL OFFICES, PERSONAL AND PUBLIC SERVICE FACILITIES a Client and v isitor areas, office areas and related toilet rooms shall be made accessible (2-712b-2A) b Conference rooms, counseling rooms or cubicles and similar areas shall be made accessible (2 712b 2B) c Emplovee work areas shall have a 36 minimum clear access (2712b-2C) SALES FACILITIES a General sales, displav and office areas together w ith related toilet rooms must be accessible (2-712b-3A) b Sales emplovee work stations shall be located on accessible levels Employee work areas shall be accessible to emplovees in wheelchairs, and the customer side of sales or checkout stations shall be accessible (2-712b-3B) c This facilitv requires.. check stands accessible to the phvsicall) handicapped based upon 1 for 8 checkstands or less, 2 for 9 or more (2 712b 3C) d Where quick check stands are prov ided at least one shall be ac cessible (2 712b-3C) e Check stands shall be made accessible bv providing a 36 aisle on she customer side of the stand (2-712b 3C) f Accessible check stands shall be identified bv the International Symbol of Accessibility and shall state "This check stand to be open at all limes for disabled customers (2-712b-3C) RETAIL GROCERY STORES (Requirements are slated in AB 179, effective July 1, 1984 ) 2 Toilet rooms must be p-o\!ced for the public in stores eonta.n- ing more lvan 20,000 sq ft of floor b. The tcile! roorrsfc' 'hepuVic -nay be the lame as those pr e-i •':>: tr.e c Scv^ra'e fsr V a :v-a' be 3-ov.dcd fc- esc*1 sex c rare czroed rec'j.'t—e-ts shell be sz'.ii.'.ea e Doors shall be self closing f Hand washing facilities shall be provided in or adjacent to toilet rooms and shall be equipped with hot and cold water g Hand washing detergent and sanitary towels or hot air blowers shall be provided in permanent!) installed dispensing devices SHOPPING CART THEFT PREVENTION BARRIERS a Public entrances and exits shall be accessible to and usable by the handicapped (2-712b-3El) b Barriers shall provide a 32 clear width opening for handicap- ped ingress and egree (2-712b 3E2) c Note on the plans that shopping cart theft prevention barriers shall comply with the requirements of Sect 2-712b-3E yi FITTING OR DRESSING ROOMS a Where fitting/dressing rooms are provided for male or female customers, one for each type shall be usable by the ph>jically handicapped (2712b-3F) b Minimum dimension of room shall be 60 x 60 (2-712b-3F) c Bottom of the mirror shall be located within 20 of the floor (2-712b-3F) d Height of clothing hooks shall not be greater than 48 from the floor (2-712b-3F) 3 3/POLICE DEPARTMENT, LAW ENFORCEMENT, FIRE DEPART- / MENT FACILITIES AND COURTROOMS a Office areas, conference rooms, classrooms, dispatch rooms and similar areas and related sanitary facilities shall be accessible (2-712b-6A) b Detention area visitor rooms shall be made accessible (2712b-6B) c At least one detention cell facility with supporting sanitary facilities shall be made accessible (2-712b-6C) d Courtroom areas including judges' chambers and bench, counsel tables, jurj box, witness stand and public seating areas shall be made accessible (2-712b-6D) 3/ FACTORIES a Major or principal floor areas shall be made acessible (2-712c-2A) b Office areas shall be made accessible (2-712c-lB) c Sanitary facilities serving the above shall be made accessible (2-712c-lC) 3S/ WAREHOUSES a. Warehousing areas which are located on the floor nearest grade shall be made accessible (2-712c-2A) b Warehousing are?j on o'her floors that are provided with access by level entry, ramp or elevator shall r>e made accessible (2-712c-2A) c Office areas nail be sci^sible (2 712c-2B) d Sanitary fsci'.ties serv.ng tne above b« made Sircets ble (2-712c-2C) CROUP R-l HOTEL, MOTEL AND DORMITORY OCCUPANCY REQUIREMENTS 36,/Applies to pnvalel> and publiclv funded hotels, motels and dormitorv, / buildings and complexes (2 1213a) a Provide guest room(s) or dormitory room(s) together wilh their sanitarj facilities that are accessible to and usable by the ph>sically handicapped (2 1213a-l) b Hotel, motel and dormitory bathrooms bevond those required in item "a' above need not comply with the provisions of Sec 2-1213d provided all bathroom entrance doors have a clear open- ing width of 32 inches and are sliding or swing out from bathroom (2 1213d Exception 1) c Every entry, opening or passage door opening to any area must have a 32 ' mm clear opening (2-1213a 2) d Public and common use rooms shall be made accessible (2 1213a-3) e Recreational facilities including swimming pooh shall comply with Sections 2-611c and 2-M07a (2-1213a-4) f Bathroom entrance doonvays shall ha\e an 18* clear space to the side of the strike edge of the door on the sw ing side of the door (2-1213d-l) g When accommodations are provided with kitchen units, at least one and no less than one for eve-y 25 of such accommodations provided, shall compK relative to accessible kitchen facilities with subsection 2-1213b-2,3,4 (2-1213a-5) ADDITIONS, ALTERATIONS AND REPAIRS TO EXISTING BUILDINGS (2-110b-llB4) S~\ 37 J The area of specific addition, alteration and/or repair, shall complj ^—s with the provisions of this Code (a J The primary entrance to the building and path of travel to the ^—^ specific area shall be accessible to the handicapped persons Restrooms, water fountains, and public telephones which serve said specif.c area shall oe accessible to hardicapped persons (c ) Information regarding handicapped accessibhty shall be posted in lobby per Sec 2-522b-8 Job Address_ Owner DOCUMENTATION OF UNREASONABLE HARDSHIP Plan File No._ Date It is requested that the above named project be granted an exception from the requirements of the State of California Title 24 accessibility, as specifically noted below: 1. EXCEPTIONS REQUESTED ESTIMATED COST OF ITEMS TO BE EXCEPTED 2. The cost of all construction without excepted items, is _. 3. The impact on financial feasibility of the project, if the requested exception is not approved is_ . it. The facility is used by the general public for the purpose of 5. The exceptions being requested will not penalize handicapped accessibility as equivalent facilities are available as follows: (Complete if over$67,813 value in No. 2 above) 6. Exceptions requested, and data provided, by:_ NAME ADDRESS SIGNATURE TELEPHONE Findings and Decision of the Enforcing Official: Signature of Enforcing Official Date HCA-1 22786 REMODEL OR TENANT IMPROVEMENT CONSTRUCTION VALUATION The Building Official is mandated by State law to determine the value of work proposed in each application for a Building Permit. The value to be used, shall be the total value of all construction work for which the periut is issued as well as all finish work, painting, roofing, electrical, plumbing, heating, air conditioning, elevators, fire exting- uishing systems and any other permanent equipment. Uniform Building Code Section 304 (a) ********************** *_*_*-<.* ******************************************** •APPLICANT PLEASE COMPLETED SITE ADDRESS JLpS-j- Co(ZT& 1>5L< SJoZfTt- PLAN CHECK NO. £7 - / DESCRIPTION 0? PROPOSED WORK AREA OF II REMODEL I I TENANT IMPROVEMENT II ADDITION PROPOSED WORK INCLUDES: NEW SUSPENDED CEILING I1 YES II NO NSW HVAC O YES [1 NO NEW FIRS SPRINKLERS II YES [1 NO NEW PARTITIONS II YES |~1 NO NEW PLUMBING II YES II NO NEW ELECTRICAL II YES CD NO HAS A CONTRACTORS ESTIMATE BEEN RECEIVED FOR THE PROPOSED WORK?[ ]YES [ ]NO ITEMIZED COST ESTIMATE IS ATTACHED [ ] YES [ ] NO I CERTIFY THE VALUE OF ALL PROPOSED CONSTRUCTION WORK COVERED BY THE PERMIT APPLICATION INCLUDING: ALL STRUCTURAL WORK, FINISH WORK, PAINT- ING, ROOFING, ELECTRICAL, PLUMBING, HEATING, AIR CCNDITICMNG, ELEVATORS, FIRS EXTINGUISHING SfSTEMS, AND ALL PERMANENT EQUIPMENT IS:§ THIS VALUE IS BASED ON: 0 DESIGNER'S ESTIMATE CZi CC\T?..-C7C? S ~STI.••..-7Z 1 I OTHER, DESCRIBE BASIS THE ABOVE INFORMATION IS TRUE AND CORRECT I I APPLICANT [1 DESIGNER II CONTRACTOR********************************************************************** PLAN CHECKER USE ONLY THE VALUE IS ACCEPTABLE II YES II NO AN ITEMIZED COST BREAKDOWN IS REQUIRED TO CONFIRM THE ESTIMATED CONSTRUCTION VALUE. II YES I1 NO BY: DATE: 4/22/85 Page 1 of 2 Plan File No. 23 - Remodel Or Tenant Improvement Information Form S" } Jurisdiction Project Address_,jk?-S"2, Co FZT Date JO- 9- <? REMOOCL OR TENANT BUILDING CODE INFORMATION REQUIRED PRIOR TO PLAN SUBMITTAL In order to complete a plan review of a remodel or tenant improvement within an existing building it is necessary that the information in Items 1-11 be provided or the approved plans be provided for the existing building. Circle the existing type of construction for this building I, II-FR., II-lhr., II-N, Ill-lhr., III-N, IV, V-lhr.,(5^b Does this building have fire sprinklers throughout7 (^*) No Does the proposed project create a change in use or occupancy classification7 Yes No Describe the previous use of the project area Describe the proposed use of the project area © © © Existing Building Area Improvement Area_ How many stones are in this building7_ What story is the improvement on7 Does this project involve alterations to Existing fire walls Yes No Existing floor or roof loads Yes No Existing building structure Yes No Existing HVAC equipment Yes No Existing electrical service loads Yes No Existing lighting Yes No If "YES", see #10 below If "YES", see #10 below What is the approximate date that construction of the existing building was permitted7 ENERGY CONS-RVATION Which of the following were checked and approved for Title 24 Energy Conservation at the time the origins! building was approved Building envelope Area lisu^_-o eoo-p'ner.t ves No vcs Nfo V&'LS' Sss^rs \es Will the proposed project s_giifi:aitlv r.ter ar\ eicrrer.t that v.zs app~cvecl7_Yes, No If "YES", see #10 below HANDICAPPED ACCESS FACILITIES Which of the following has been approved for compliance with the handicapped access standards of Title 24, CAC Building entrance doors Yes No Existing public restrooms Yes No Parking i access to the building Yes No Building stairs & elevators Yes No ENERGY DOCUMENTATION a. Remodels to existing conditoned spaces require that a Form CF-1 (attached) be co-npleted, signed and imprinted on the plans. Additionally, if the building envelope, lighting or HVAC equipment are to be altered or added, appropriate State required documentation must be submitted. b. Provide copies of all existing CF-1 Forms for this building. c. Provide a copy of any existing approved energy design for the building. 12/16/87 Page 2 of PLANS a. Plans shall clearly show all demolition and new construction proposed b. Plans shall clearly show exit systems, fire rated construction details, occupancy require- ments, handicapped access provisions and other requirements necessary to show the work will comply with adopted codes and ordinances. c. If structural revisions or increased ]ive or dead loads are proposed the structural plans details and calculations shall be provided and shall be signed by a California licensed engineer or architect. d. If electrical system revisions or increased electrical loads are needed provide electrical plans and specifications showing location of panels, panel schedules, existing service size, existing building load, additional loads, wiring method, exit signs and emergency lighting when required. e. If plumbing revisions or additions are proposed provide plumbing layout, details and specifi- cations. Include sizing calculations when necessary to justify pipe sizes. f. All sheets of the plans are requried to be signed by the responsible designer. Information is provided by Title Datei Jurisdiction Prepared byi D Bldg. Dept. PLAN CHECK NO. 81 - > BUILDING ADDRESS 2-O S~z. VALUATION AND PLAN CHECK FEE t^ T?E~L, APPLICANT/CONTACT P/47T/ BUILDING OCCUPANCY &- - -2- TYPE OF CONSTRUCTION U-G PHONE -2-9? - QI0O J/- DESIGNER PHONE CONTRACTOR PHONE BUILDING PORTION T. I. Air Cc-ditfo-i-.- CcTir. ere 18.1 •^ • •*r 3 5 _ - c • *; ; a - Res. or CorruT. Fire S-orinklers Total Value BUILDING AREA 3-0 <?4Z^ j VALUATION MULTIPLIER /?. ^2- ' n',-' ! . - 1 @ VALUE 4-0( ^0 &/ — 1t ^01 , ^0^ Building Permit Fee $ Plan Check Fee $ COM ME N TS SHEET / OF / 12/87 BUILDING PLANCHECK ENGINEERING CHECKLIST DATE; PLAN CHECK NO . PROJECT ADDRESS: 0 ,LEGEND ITEM COMPLETE 'ITEM INCOMPLETE - NEEDS YOUR ACTION N/A - NOT APPLICABLE rr PROJECT NAME: \//rFK D D D D D LEGAL REQUIREMENTS Site Plan 1. Provide a fully dimensioned site plan drawn to scale. Show: north arrow, property lines, easements, existing and proposed structures, streets, existing street improvements, right-of-way width and dimensioned setbacks. 2. Show on site plan: Finish floor elevations, pad elevations, elevations of finish grade adjacent to building, existing topographical lines, existing and proposed slopes, driveway with percent (%) grade and drainage patterns. 3. Provide legal description and Assessors Parcel Number. Discretionary Approval Compliance 4. No discretionary approvals were required. 5. 6. Project complies with all Engineering Conditions of Approval for Project No. . Project does not comply with the Conditions of Approval for Project No. following Engineering Conditions complied with by: Field Review Date: 7.Field review completed. No issues raised. 8. Field review completed. The following issues or discrepancies with the site plan were found: A. Site lacks adequate public improvements. B. Existing drainage improvements not shown or in conflict with site plan. C. Site is served by overhead power lines (Future Improvement Agreement required). D. Grading is required to access site, create pad or provide for ultimate street improvement. E. Site access visibility problems exist. Provide onsite turnaround or engineered solution to problem. F. Other: Dedication Requirements 9. No dedication required. 10. Dedication required. Please have a registered Civil Engineer or Land Surveyor prepare the appropriate legal description together with an 8-1/2" x 11" plat map and submit with a title report and the required processing fee. All easement documents must be approved and signed by owner(s) prior to issuance of Building Permit. The description of the dedication is as follows: Dedication completed, Date: By: Improvement Requirements 11. No public improvements required. SPECIAL NOTE: Damaged or defective improvements found adjacent to building site must be repaired to the satisfaction of the City inspector prior to occupancy. 12. Public improvements required. This project requires construction of public improvements pursuant to Section 18.40 of the City Code. Please have a registered Civil Engineer prepare appropriate improvement plans and submit for separate plan check process through the Engineering Department. Improvement plans must be approved, appropriate securities posted and fees paid prior to issuance of permit. The required improvements are: Improvement plans signed, Date: By: 13. Improvements are required. Construction of the public improvements may be deferred in accordance with Section 18.40 of the City Code. Please submit a recent title report on the property so we may prepare the necessary Future Improvement Agreement. The Future Improvement Agreement must be signed, notorized and approved by the City prior to issuance of a Building Permit. Future Improvement Agreement completed, Date: By: I Grading Requirements 13a. Inadequate information available on site plan to make a determination on grading requirements. Please provide more detailed proposed and existing elevations and contours. Include accurate estimates of the grading quantities (cut, fill, import, export). 14. No grading required as determined by the information provided on the site plan. 15. Grading Permit required. A separate grading plan prepared by a registered Civil Engineer must be submitted for separate plan check and approval through the Engineering Department. NOTE: The Grading Permit must be issued and grading substantially complete and found acceptable to the City Inspector prior to issuance of Building Permits. Grading Inspector sign off. Date: Miscellaneous Permits By: 16. Right-of-Way Permit not required. 17. Right-of-Way Permit required. A separate Right-of-Way Permit issued by the Engineering Department is required for the following: 18. 19. Sewer Permit is not required. Sewer Permit is required. A Sewer Permit is required concurrent with Building Permit issuance. The fee required is noted below in the fees section. 0. Industrial Waste Permit is not required. Industrial Waste Permit is required. Applicant must complete Industrial Waste Permit Application Form and submit for City approval prior to issuance of Building Permits. Permits must be issued prior to occupancy. Industrial Waste Permit accepted - Date; /VV^f By; ^/ Fees Required 22. Park-in-Lieu Fee Quadrant; ' Fee Per Unit:Total Fee: 23. Traffic Impact Fee Fee Per Unit: —Total Fee:AL. 24. Bridge and Thoroughfare Fee Fee Per Unit: ' Total Fee- 25. Public Facilities Fee required. 26. Facilities Management Fee Zone' Permit No. ~~27. Sewer Fe^es Fee; 28. Sewer Lateral Fee;: .spA JJLSi required: REMARKS: Fee: EDU's:&ee ENGINEERING AUTHORIZATION TO ISSUE PERMIT BY>-- H^V^ ^T^ ,< Date: - A) U O u u u c c c10 10 10 E31JD PLANNING CHECKLIST Plan Check No. APN: PI anner Address ffl/fo Phone 438-1161 (Name) Type of Project and Use Zone CZS^fc^?k// Facilities Management Zone 3 Legend Item Complete Item Incomplete - Needs your action 1, 2, 3 Number in circle indicates plancheck number that deficiency was identified Environmental Review Required: YES DATE OF COMPLETION- NO TYPE Compliance with conditions of approval7 If not, state conditions which require action. Conditions of Approval D IDD Discretionary Action Required: YES APPROVAL/RESO. NO. PROJECT NO. - NO -TYPE DATE: OTHER RELATED CASES: Compliance with conditions of approval? require action. Conditions of Approval Coastal YES NO X DATE OF APPROVAi which Compliance with conditions of approval? If not, state conditions which require action. Conditions of Approval 2560 ORION WAY CARLSBAD, CA 92008 TELEPHONE (619) 931-2121 PROJECT \1 ARCH ITECT OCCUPANCY >SiSFr City of Cartebab FIRE DEPARTMENT PLAN CHECK REPORT C-n ADDRESS 20^2. ADDRESS . ADDRESS CONST TOTALSQ FT PAGE 1 OF. APPROVE DISAPPROVED PLAN CHECKS . PHONE _ PHONE STORIES APPROVAL OF PLANS IS PREDICATED ON CONFORMING TO THE FOLLOWING CONDITIONS AND/OR MAKING THE FOLLOWING CORRECTIONS 1 2 3 .12 .13 PLANS, SPECIFICATIONS, AND PERMITS Provide one copy of floor plan(s), site plan, sheets Provide two site plans showing the location of all existing fire hydrants within 200 feet of the project Provide specifications for the following Permits are required for the installation of all fire protection stand pipes, dry chemical, halon, C02, alarms, hydrants) Plan must be approved by the fire department prior to installation The business owner shall complete a building information letter and return it to the fire department FIRE PROTECTION SYSTEMS AND EQUIPMENT The following fire protection systems are required -O. Automatic fire sprinklers (Design Criteria r\5> D Dry Chemical, Halon, COz (Location D Stand Pipes (Type _ /Uf-p'A l3> D Fire Alarm (Type/Location 7 Fire bxtmguisher Requirements , ""dl One 2A rated ABC extinguisher for each If?OOP sq ft or portion thereof with a travel distance to the nearest extinguisher not to exceed 75 feet of travel D An extinguisher with a minimum rating of to be located D Other 8 Additional fire hydrant(s) shall be provided EXITS Exit doors shall be openable from the inside without the use of a key or any special knowledge or effort A sign stating, " This door to remain unlocked during business hours" shall be placed above the mam exit and doors UJfrtetu EXIT signs (6" x 3A" letters) shall be placed over all required exilts and directional signs located as necessary to clearly indicate the location of exit doors GENERAL Storage, dispensing or use of any flammable or combustible liquids, flammable liquids, flammable gases and hazardous chemicals shall comply with Uniform Fire Code Buildmg(s) not approved for high piled combustible stock Storage m closely packed piles shall not exceed 15 feet in height, 12 feet on pallets or in racks and 6 feet for tires, plastics and some flammable liquids If hich stock pil- ing is to be done, comply with Uniform Fire Code, Article 81 Additional Requirements ,15 Comply with regulations on attached sheet(s) nmer ^--— )CPlan Examiner Date- Report mailed to architect . Met with .Attach to Plans COMMERCIAL/INDUSTRIAL APPLICATION FORM FOR INDUSTRIAL WASTE DISCHARGE PERMIT CITY OF CARLSBAD APPLICATION: NEW (CHECK ONE) REVISED BUILDING P.C. NO. APPLICATION N0.:_ INDUSTRIAL CLASS: DATE: Signature of City Representative APPLICATION FOR INDUSTRIAL WASTE DISCHARGE PERMIT A.GENERAL: APPL ICANT : SITE ADDRESSi TYPE OF BUSINESS; APPLICANT'S ADDRESS; B. WASTES AND PROCESSING: (Check where applicable) Domestic Waste Only Industrial Waste Discharged to Sewer Industrial Waste NOT Discharged to Sewer GENERAL DESCRIPTION OF WASTE (Chemical and Physical Characteristics of proposed waste): ' GENERAL DESCRIPTION OF PROCESS (If Applicable): C. WASTES TO-BE DISCHARGED TO SEWER WASTE:TREATED: (Check One) UNTREATED? QUANTITY: AVERAGE (Daily) MAXIMUM GPD GPD (Gallons Per Day) APPLICANT OR REPRESENTATIVE OF FIRM; TITLE: SIGNATURE;DATE: r (Enmity nf J WILLIAM COX M D . Ph D DIRECTOR (61 Bl 236-2237 STEVEN A ESCOBOZA ASSISTANT DIRECTOR (619) 236-7033 DEPARTMENT OF HEALTH SERVICES 1700 PACIFIC HIGHWAY SAN DIEGO CALIFORNIA 92101-2417 HAZARDOUS MATERIALS QUESTIONNAIRE New State law, effective July 1, 1989, (AB 3205, Chapter 1589.-Statutes 1988) prohibits a City or a County from issuing Certificate of Occpancy if a business will handle Hazardous Materials unless the business has met or Is meeting the requirement of a Business Plan for Emergency Response with the San Diego County Department of Health Services, Environmental Health Services, Hazardous Materials Management Division. The new law may also prohibit the permitting of a facility handling Acutely Hazardous Materials to be constructed within 1,000 feet of the outer boundary of a school (K thru 12) unless first meeting the requirements of a Risk Management and Prevention Program. To determine whether your business is subject to these new requirements, please read and complete this questionnaire. If the answer to any of the questions below is yes, applicant nust contact the Hazardous Materials Management Division, 1255 Imperial Ave., 3rd H., San Diego, CA 92138-5261. Telephone: (619) 338-2222.. Business Name Vitek Systems Distributior Mailing Address 920 Boardwalk Avenue Site Address 2052 Corte Del Nogal Contact Person Bruce L. Sanguinetti City San Marcos State CA City Carlsbad CA Telephone 619-744-8305 Zip 92069 Zip 92009 YES NO 1. [ 1 [X] 2. C ] [X] 3. [ 4. [ 1 CX] ] [X] 5. [ ] [X] 6. [ 7. [ ] [X] J[X] Will your business activity generate Hazardous Waste in any quantity, in any physical form (solid, liquid, gas)7 Will your business at any one time store, use or handle Hazardous Substances in quantities equal to or greater than 55 gallons, 500 pounds or 200 cubic feet of compressed gas7 Will your business store, use or handle Carcinogens or Human Reproductive Toxins in any amount' Will your business store, use or handle Gases with Threshold Limit Values or Time Weighted Averages of 10 parts per million or less7 Will your business use an existing or install an Underground Storage Tank for Hazardous Substances or Hazardous Wastes7 Will your business store, use or handle Acutely Hazardous Materials7 If your business will be handling Acutely Hazardous Materials, will your business be located within 1,000 feet from the outer boundary of a school? 8. [ ] [X]Is your business listed on the reverse side of this form7 Briefly Describe Nature of the Business Activity or Process: Computer Distrabution Printed Naimj of Owner or Authorized Agent L. Sanguinetti TitleExecutive Vice President Sufnatun 6f Owner or aphorized Agent I declare under penalty of perjury that to the rH j tfffi best of my knowledge and belief the responses MA/v pate /Z-*f *ffy made herein are true and correct. BUILDING INSPECTION DEPT. PLAN FILE NUMBER Init. For\J)HS-llMMD/i»se Only o/ness Plan Completed [ ] RMPP Completed Reviewed By IN—3140 (6-89) Date Reviewed By Date Estab. # H Distribution: Original and 1st copy to DHS-HMMD. 2nd copy to Applicant. 3rd copy to City/County Plan Check SAN DIEGO AIR POLLUTION CONTROL DISTRICT 9150 CHESAPEAKE DRIVE, SAN DIEGO, CALIFORNIA 92123-1095 (619) 694-3307 [ AIR POLLUTION CONTROL QUESTIONNAIRE | New State law, effective July 1,1989, (AB 3205, Chapter 1589 Statues 1988) requires that an applicant for a building permit provide information indicating whether a permit is required from the Air Pollution Control Distnct This law further prohibits a City or a County from issuing Certificate of Occupancy unless a business has complied with provisions of the law that are administered by the Air Pollution Control Distnct The new law also imposes additional permitting requirements for a facility within 1,000 feet of the outer boundary of a school (K thru 12) To determine whether your business is subject to these new requirements, please complete this questionnaire Business Name (DBA) c Vitek Systems Distri Mailing Address 920 Boardwalk Avenue bution San Street Address of Proposed Facility 2052 Corte Del Nogal YES NO D 00 1 Will the intended occupam ft- City Ma EC 6s City Carlsbad t install or use at Contact^Pera CA CA w of the equipm pn Phone pgfie (619 State Zip 92069 Zip 92009 ent listed on the Listing 431-2500 ) 744-8305 of Air Pollution Control Distnct Permit Categones (IF ANSWER TO 1 IS YES, APPLICANT MUST CONTACT THE APCD DIRECTLY) D EH 2 (Answer only if the answer to 1 above is YES) Will the subject facility be located within 1000 feet of the outer boundary of a school (K thru 12) as listed in the current Directory of School and Community College Distncts, published by the San Diego County Office of Education and the current California Pnvate School Directory, compiled in accordance with provisions of Education Code Section 33190 Briefly Descnbe Nature of the intended Business Activity Distribute Computer Products Indicate Permit Categones Name of Owner/ Bruce >r Authorized Agent Sanguinetti Title Executiv Vice President Signature of Owner or Authcfazed Agent •T {]U->ytsLL A_ Date f I declare under penalty of perjury that to the best of mv knowledge and belief the responses made herein are true and correct Building Inspection Plan File No Initials APCDt^eorih// STATUS EXEMPT FROM APCD PERMIT REQUIREMENTS Confirming Stamp APPROVED FOR ISSUANCE OF BUILDING PERMIT, BUT NOT FOR OCCUPANCY Confirming Stamp APPROVED FOR OCCUPANCY (APCD Authority to Construct Issued) Confirming Stamp March 15, 1990 Vitek 2052 Corte Del Nogal Carlsbad, Ca 92009 BUILDING PERMIT 89 1451 You have installed a door between the one hour corridor and the non rated corridor which does not comply with the handicap regulations. These regulations require an 18 inch space past the strike edge. ^"Please^correct your installation to comply and call for another inspection. DARNELL, PLANCHECKER c: Inspector Camero Brodwolf 2O75 Las Palmas Drive • Carlsbad California 92OO9 (619) 438-1 161 In a I March 14, 1990 Vitek 2052 Corte Del Nogal Carlsbad, Ca 92009 BUILDING PERMIT 89 1451 At the request of the inspector you have installed at 4/0 x 6/8 door at the entrance to the bathrooms to maintain the integrity of the one-hour corridor. The handicap regulations require an 18 inch space past the strike edge for interior doors. The installation you have completed does not provide this distance. A drawing jcs provided to help you understand what is required. Please make this correction and call for another inspection. CARTER DARNELL, PLANCHECKER c: Inspector Camero Brodwolf 2O75 Las Palmas Drive Carlsbad, California 92OO9 (619) 438-1 1 61 Sec 3304 (i 1) 1 continued Interpretation | An interesting point' If you have a change in floor level at a doorway of more than one half inch say one inch, you can still accomplish this transition and stay in compliance with the regulations One half inch of the change can take place at the threshold, the other half inch shall be made to comply with the requirements for ramps and would require six inches of run at 1 12 slope to accommodate this change, but it does solve the problem 2. Level Floor or Landing. B. The floor or landing on each side of an exit door shall be level and clear The level area shall have a length in the direction of door swing of at least 60 inches and the length opposite the direction of door swing of 44 inches as measured at right angles to the plane of the door in its closed position EXCEPTION: 1 In Group R Occupancies.the level area shall have a length both in the direction of door swing and opposite the direction of door swing of 44 inches as measured at right angles to the plane of the door in its closed position C.The width of the level area on the side to which the door swings shall extend 24-inches past the strike edge of the door for exterior doors and 18-inches past the strike edge for interior doors 24" mm exterior 18" mm interior Figure 33-2 This diagram illustrates the specific requirements of these regulations and is intended only as and aid lor building and construction Interpretation A picture is worth a thousand words So here's a picture of a level landing Strike side clearance is needed to allow wheelchair users to get out of the way of the door when opening it Without this clearance the person would have to open the door and back away from the door at the same time A feat that takes three hands 100 -V^.'-c^-.f-V-r-'^-'-.-rtwaASr*.'^^,.i-•*&/••ia'<'^>V*,'-.>.-;;vasj-; -"V^. ;u-*i.r ,.- .,-_» rGom rn tini t^ft D e ve I o p m e n t$ January 16, 1990 Rick Alexander The Alexander Co 8885 Rio San Diego Dr 107 San Diego, Ca 92108 BUILDING PERMIT 891451 2052 CORTE DEL NOGAL SUITE B Our Building Inspectors report that the subject suite of 28,000 square feet was occupied over the weekend without a final inspection. This letter is to inform you that Vitek Distribution Group, your tenant is occupying the space illegally, and I assume is willing to share with you the liability incurred. Please have the balance of the work completed immediately, including the exit that has been omitted, and request a final inspection. If you, your tenant or your contractor have any questions, please contact Carter Darnell in my office. 'AMARTIN ORENYAK, DIRECTOR cd (J c Vitek Distribution Group Brodwolf Construction Wayne Morgan, Mer Camero 2OY5 Las Palmas Drive-Carlsbad, California 92OO9-4859-(619) 438-1161 fVUU •-'&r^*—^^s-'^^tf-<^'m,"2i&W:K£^'iS ^Wsftr-f^m*-*'1''**-''&<•'***<*s ^ - * -'^rGomrriunify|5DeAAeloprnent January 10, 1990 The Alexander Co 8885 Rio San Diego Dr 107 San Diego, Ca 92108 BUILDING PERMIT 89 1456 2052 Corte Del Nogal Our Building Inspector has determined that the portion of the dropped ceiling that is existing in this tenant improvement does not comply with present seismic regulations. The new portion of the ceiling will comply, and we anticipate the existing portion will be made to comply before final inspection is requested. If you have any questions please contact Senior Inspector Wayne Morgan in my office. MARTIN ORENYAK, DIRECTOR cd c Wayne Morgan Mer Camero r4^-»- -*-< - 2O75 Las Palmas Dnve» Carlsbad, California 92OO9-4859»(619) 438-1161